1. Reading out the logger copies data from the logger to your computer allowing you to save the data in a datafile and view the plot During readout the logger continues to record data unless you have stopped the logger or the logger is full To read out the logger 1 Click the Readout icon tA on the toolbar 2 Awarning message appears indicating the logger is currently logging Click Don t Stop to continue logging or Stop to end logging before reading out 3 After reading out the logger you are prompted to save the datafile Type a name and select a location for the file and click Save The Plot Setup window appears which is described in the next section 16 Getting Started Using HOBOware with HOBO Data Loggers Plotting and Analyzing Data After you read out a logger and save the datafile or any time you open an existing file the Plot Setup window appears Even if you only intend to export the data to another format you must plot the data first Plot Setup Description 90000006 Select Series to Plot All 0 None Series Measurement Units 1 DO conc mg L v v 2 Temp e E 3 Batt V Select Internal Logger Events to Plot All 0 None Event Event Type Units a V 1 Coupler Detached 2 Coupler Attached 3 Host Connected 4 End Of File Offset from GMT 5 gt 13 0 hours 0 GMT Y Data Assistants Process we Dissolved Oxy
2. options in this pane To configure a test launch set Start Logging to Now choose a fast logging interval such as 30 seconds change any other settings as desired and then click Start HOBOware displays the progress of the launch and warns you not to unplug the logger while it is being configured Normally when the launch is finished you can unplug the logger and deploy it For this test leave the logger plugged in so you can become familiar with checking the status reading it out and plotting data Getting Started Using HOBOware with HOBO Data Loggers 13 14 as described below Device Identification Device Details Mr Battery Leve Gog 100 Devine HOBO URSOHOS GM Gocupancy Light Syma A Beriary Uei 4 of S12 KB 0 Manufacturer Onset Computer Cor eS a Stops Logging At Memory Ful Description 1068743 Last Launched OF L7 12 00 15 05 AM GMT 04 00 Sonal Number 19069743 Deployment Number 8 Femvware Version 3 07 Logging interval Oh tm 1s Curent Status Launched Logging Current States Button Up Calibration Button Up Current Readings Soreen Refresh Iierval 0 5 sac Number bbraaurriwrrt Waher Units l Lizig Loo on Cocupancy 1i d occupied d 3 7 Help e Device Identification This pane displays identifying information for the device currently connected including the device type description entered at launch time serial number and firmware version e Device Details This pane display
3. ady Dev HOBO UX90 005 6M Occupancy Light S N 19088743 1 device connected To disconnect the device unplug it from the USB cable Getting Started Using HOBOware with HOBO Data Loggers 9 Connecting a Base Station Coupler Some loggers require an optic USB base station coupler to connect to the computer Consult the manual that came with the device for specific information about required base stations couplers Steps 1 Open HOBOware 2 Plug the base station coupler cable into a USB port on the computer Important Make sure the base station coupler is the correct model for the logger you want to use Consult the logger device user Manual if you are unsure 3 Attach the logger to the base station coupler as described in the in the logger device manual paying close attention to proper alignment Windows If the base station coupler or logger has never been connected to the computer before it may take several seconds for the computer to detect the new hardware and report that it has connected successfully A message may display indicating that you need to reboot before you can use the device This is optional you do not need to reboot at this time The status bar at the bottom of the HOBOware window will update to reflect that the logger is connected At this point you can begin using the device To disconnect the logger simply unplug it from the base station coupler Wait for the status bar to update the number of
4. ame of the logger currently selected Checking Logger Status appears at the top of this pane which also includes the serial number deployment number and current battery level To check the status click the Status icon on the toolbar cial Use the Description field to type up to a 40 character name for The Status window appears displaying information about the device the logger deployment This description will be used as the default file name when you read out the logger and save the data It will also be the default title on the plot Click the Status button in this pane to see the current status of the logger and the settings used on the previous launch e Sensors This pane displays a list of the sensors available for the logger Choose the sensors or channels that you wish to log in this deployment and select any external sensors you may be using if applicable This pane also displays any utilities available for your logger such as Alarms Scaling and Filters e Deployment Use this pane to set the logging interval which is the rate at which you want the logger to record data and to select when you want the logger to start logging This pane also displays the logging duration which is the approximate time it will take to fill the logger memory based on the logging interval sensors and other settings currently selected For some loggers you can also set a sampling interval choose when to stop logging and select other
5. ccseeeeeseeeeeeeeeeeeseeeeeeseeeeeens 17 Getting Started Using HOBOware with HOBO Data Loggers This software is furnished in accordance with a separate license agreement included with the software and subject to any restrictions set forth therein For more information about Onset s licensing terms and policies contact Onset Customer Service at 1 800 LOGGERS or visit http www onsetcomp com legal Contact Information For support please contact the company that you bought the products from Onset Computer Corporation or an Onset Authorized Dealer Onset Computer Corporation 470 MacArthur Blvd Bourne MA 02532 Mailing Address P O Box 3450 Pocasset MA 02559 3450 Phone 1 800 LOGGERS 1 800 564 4377 or 508 759 9500 Fax 508 759 9100 Technical support hours 8 AM to 8 PM ET Monday through Friday Customer support hours 8 AM to 5 PM ET Monday through Friday Email loggerhelp onsetcomp com Main Onset Web site http www onsetcomp com 2009 2014 Onset Computer Corporation All rights reserved Onset HOBO and HOBOware are trademarks or registered trademarks of Onset Computer Corporation for its data logger products and configuration interface software Microsoft Windows and Excel are registered trademarks of Microsoft Corporation Macintosh is a registered trademark of Apple Inc Java is a registered trademark of Oracle and or its affiliates Keyspan is a registered trademark of InnoSys Inc All other trademarks are
6. devices before continuing To attach another logger via a base station coupler remove the logger leaving the base station coupler connected and then connect the next logger To disconnect the base station coupler unplug it from the USB port 10 Getting Started Using HOBOware with HOBO Data Loggers Connecting a Device Using a Serial Cable Some loggers use a serial cable to connect to the computer If your computer does not have a serial port and you are using a device that requires a serial cable you can use a Keyspan adapter as described in this section Steps 1 Open HOBOware 2 Plug the 9 pin end of the serial interface cable into a serial port on the computer or into a Keyspan adapter that is plugged into a USB port 3 Plug the other end of the serial interface cable into the communications port on the device Refer to the diagram and instructions that came with the device if you need help finding the port 4 Windows If you are using a serial port other than COM1 you will need to configure HOBOware to use another port To change the setting go to File gt Preferences gt Communications gt Serial Ports Note that checking multiple serial ports can take some time even when no devices are attached 5 Select the logger from the Select Device window and click OK The status bar at the bottom of the HOBOware window will update to reflect that the device is connected and selected At this point you can begin
7. gen Assistant a What s This 8 Growing Degree Days Assistant Manage v Help Getting Started Using HOBOware with HOBO Data Loggers 17 The Plot Setup window contains the following information Description This field shows the description you entered at launch time Keep this description or type a new one The description will be the title of the plot Select Series to Plot Select the series you want to appear on the graph and the units if applicable Some series will be selected automatically Click the checkboxes to select other series or use the All and None buttons for selecting and deselecting all series Select Internal Logger Events to Plot Select any events you want to appear on the graph if applicable Use the All and None buttons to select or deselect all events Offset from GMT This field shows the offset from Greenwich Mean Time GMT also known as UTC used at launch Keep the offset shown or change it to a different one Data Assistants You can create new data series by converting logged data to other useful formats with Data Assistants Only the Data Assistants supported by that logger type will be available in this window See the HOBOware User s Guide for more information about using Data Assistants Plot Button Click Plot to display the selected sensor data ona graph Getting Started Using HOBOware with HOBO Data Loggers After you click the Plot b
8. he keys for each sensor state and event series as well as any internal events Click the icons on the toolbar to experiment with the export print viewing and customization tools available within HOBOware Hover the mouse cursor over each icon on the toolbar for a description of each tool IMPORTANT Make sure you change any test launch settings to your preferred launch settings before deploying the logger See the HOBOware User s Guide or the HOBOware Help for more information on features described in this guide and additional details about the software 20 Getting Started Using HOBOware with HOBO Data Loggers
9. luding those configured with the Setup Assistant go to Windows File gt Preferences Macintosh HOBOware gt Preferences 8 Getting Started Using HOBOware with HOBO Data Loggers Connecting Devices Connecting a USB Device You can connect most devices to the USB port by using an Onset supplied USB interface cable HOBOware Pro For instructions on connecting HOBO shuttles or using the HOBO Waterproof Shuttle as a base station refer to the shuttle s user guide Steps 1 Open HOBOware 2 Plug the large end of the USB interface cable into a USB port on the computer 3 Plug the small end of the USB interface cable into the port on the device Refer to the diagram and instructions that came with the device if you need help finding the port Windows If the device has never been connected to the computer before it may take several seconds to detect the new hardware and report that it has connected successfully One or more messages will appear indicating that new hardware has been found You may also hear a chime A message may display indicating that you need to reboot before you can use the device This is optional you do not need to reboot at this time Once the device is recognized by HOBOware the device name will appear in the status bar at the bottom of the HOBOware window as shown below The status bar also lists the total number of devices connected At this point you can access the device from HOBOware Re
10. onset HOBOware amp Getting Started Using HOBOware with HOBO dataloggers Contents CONLE DES scacs casa saan a casa saan caun E vans Gannanun Guan saanenen tenn Gannenen ins 1 MFUERO GUNG EIGN cacccccaccecesaccescccccccccueseonssscseanencasaanaccaseonecwectuconsestececeasceceeesscencaasee 4 An Overview of HOBOWa81r eC cccccccecseeeeeecaeeeeeeeeeeeeeeeseaeeeeesaaees 4 installing TIO OW ai Cassa ac sacs lena cacatatacetacatacaascenicahecanacauscenacseacoccaceseescecmsaeex cee 6 Installing HOBOware or HOBOware Pro from the Onset Website 6 Installing HOBOware Pro from the Installation CD cceee 6 Activating HOBOware Pro cccccsseececeeceseeeeeceeeeeeeeeaeaeeeeeseaeeesseaaess 7 Running the Setup Assistant cece cccccceecsseeeeeeeeeeeeeeeeeeeeeeeeeseaeneees 7 CONNECTING DEVICES sinin RR 9 Connecting a USB DeVICEC ccccccceessseseeeeeeeeeeeeeeeeeeeeesaaaaeeeeeeess 9 Connecting a Base Station Coupler ccccccseeecceeeeeeeeeeeeeeeeees 10 Connecting a Device Using a Serial Cable cccccccseseeeeeee ees 11 Working With DEVICES sisirin 12 Launching the LOQQEL ccccsseeeceeseecceeseeceeeeeeseseeeseaeeessaneeeseees 12 Checking Logger Status cccccccccccscssssseeeeeeeeseeeeeeeeeeeessaeeeeeeeeees 14 Reading Out the Logger cccccsseeeeecceeeseeeeceeeeeeeeseeaeeeeesseeseeeeseas 16 Plotting and Analyzing Data cccsscec
11. reen 4 Click Restart in the last screen so that the operating system is prepared to work with Onset devices HOBOware will not recognize your loggers until you have restarted 5 After restarting open HOBOware by double clicking the HOBOware icon in your computer s Applications folder Activating HOBOware Pro The first time you open HOBOware Pro you will be prompted to enter your license key from the email confirmation online receipt or the CD case Type the license key in the License Key Manager and click OK You will need to reopen HOBOware after entering the license key Note that you will not be required to enter the license key when upgrading to subsequent versions of HOBOware Running the Setup Assistant The HOBOware Setup Assistant appears the first time you open HOBOware to help you quickly select key settings for device types and Getting Started Using HOBOware with HOBO Data Loggers 7 serial ports units of measurement and data assistants To run the Setup Assistant click Start and follow the prompts Note The Setup Assistant is optional If you click Cancel you will be able to use HOBOware with its default settings listed below e Device Types Default is USB If you enable serial devices you can select the port to use e Unit System Default is US units e Data Assistants Default is to enable all installed data assistants Other Preferences To see all the preferences you can configure in HOBOware inc
12. s specifics about the device including battery level memory used when it is scheduled to stop logging if applicable when it was last launched the deployment number logging interval current status and current state if applicable e Current Readings This pane shows the latest readings for configured sensors and derived series if applicable Getting Started Using HOBOware with HOBO Data Loggers Testing the Logger and Sensors To verify that your logger and sensors are working and recording data properly perform the following tests When you plot the data later you should see the results of these tests in the graph Change Sensor Reading 1 Force a change in the condition you are measuring For example if you are measuring temperature change the temperature reading by holding the logger or sensor in your hands for a minute or two 2 Watch the Current Readings in the Status window change as the conditions fluctuate Change Current State 1 If you are using a U Series logger that has a button hold the button down for several seconds 2 Watch the Current State field in the Status window change to Button Down 3 Release the button The Current State field changes back to Button Up Click OK to close the Status window when the tests are complete Getting Started Using HOBOware with HOBO Data Loggers 15 Reading Out the Logger To retrieve data recorded by a logger you must read out the logger
13. the property of their respective companies Part MAN BHW GS Doc 12284 J Getting Started Using HOBOware with HOBO Data Loggers 3 Introduction This guide is intended to help you become familiar with the basic functionality of using HOBOware with HOBO data loggers including e Installing HOBOware on Windows and Macintosh e Connecting devices and e Working with devices including launching reading out and analyzing data This guide is for both HOBOware and HOBOware Pro and for Windows and Macintosh Any differences in functionality are noted For detailed information on all HOBOware features use the online help or refer to the HOBOware User s Guide at http www onsetcomp com support manuals bhw pro cd_ 12730 This guide covers HOBO data loggers See www onsetcomp com for details on setting up a HOBO ZW Series Wireless System An Overview of HOBOware HOBOware software is used for launching reading out and plotting data from HOBO data loggers With HOBOware you can also check logger status filter and export data save changes to graphs in project files and scale data with the Linear Scaling and Pulse Scaling data assistants There are two versions of HOBOware HOBOware and HOBOware Pro HOBOware Pro offers the following additional features e Support for Conductivity Dissolved Oxygen and Water Level loggers which use HOBOware Pro Data Assistants e Support for HOBO U Shuttle and Waterproof Shu
14. ttle 4 Getting Started Using HOBOware with HOBO Data Loggers HOBOnode Manager and support for wireless HOBO data nodes Launch and readout time saving options Additional data assistants Barometric Compensation Conductivity Dissolved Oxygen Grains Per Pound Growing Degree Days and kWh Importing of text data Bulk Export Tool Pie charts for UX90 series loggers Additional plot preferences font type style and color and series and value axis rules Subset statistics tool for graphing a subset of data Series cropping on plots 21 CFR Part 11 Compliance To upgrade from HOBOware to HOBOware Pro call 1 800 564 4377 and ask for Onset Customer Service Note HOBOware supports the following five languages English French German Spanish and Portuguese The HOBOware user interface can display all of these languages as configured by your computer see the HOBOware Help for details HOBOware documentation is available in English only Getting Started Using HOBOware with HOBO Data Loggers Installing HOBOware You can download and install HOBOware from the Onset website HOBOware Pro is available from the Onset website or a software CD and requires a license key which is located in the email confirmation or online receipt you received when purchasing the software or on the back of the CD case To upgrade from HOBOware to HOBOware Pro call 1 800 564 4377 and ask for Onset Customer Service Installing HOBOware or HOBO
15. using the device To disconnect the device simply unplug it from the serial cable Getting Started Using HOBOware with HOBO Data Loggers 11 Working with Devices This section covers the basics of working with loggers including launching checking status reading out and plotting data It is recommended that you perform a trial launch and readout as described in this section to familiarize yourself with the procedures before deploying your loggers Launching the Logger To launch the logger click the Launch icon ES on the toolbar The Launch window opens This window is separated into three panes which vary slightly for each type of logger and are described on the next page Launch Logger HOBO USOHD 01M Stabe Pubes beet Runtime Ny Description 10006747 Serial Number 19080743 A Deployment Number 2 Dattery Level ou 100 beg Hame Ta Lero pign EV 1 itemak State Stati TE x E Scaling T Fibers 2 Extemat Puke Raw Pulse yt Advanced 3 Loggers Battery Voltage LOD For Pulse sensor shew units CTS Depkhyment Logging Interval 1 minate F Logging Cianitian 263 8 days Stat Logging how 11 99 15 AM Stop Logging S When memory fills Hever wrapping Push Button from start Options Tun LED ott Help Ship launch window next tine Cancel Start 12 Getting Started Using HOBOware with HOBO Data Loggers e Logger Information The n
16. utton in the Plot Setup window the data appears in a graph along with other information described below HORCware Pro File Device Edit View Tools Windya Help Ties GMT 05 00 con mgl Temp F Coupler Detached CoupkrAmached Hosttonnectied End Of File wL 01 5602 Pa 315 vo TALI OLS Lb PM Legged MDL Oe fel OS 01 17 OF 000 PM 3 55 71 87 OG 16000 F 5 T3017 OF Wo era oe ea Shoa fll iii All SOO00008 i the Searles DO come mgl Seres Temp F p He peent Type Couper Detached t Ea enk Type Souler stated 1 K HE i Eren Type Hti Connected ah i y f ES Brent Type Ene of Pie i a ri P Ready Ul Dev Ho device selected Ho devices commected E e Points Table Data points including any internal events if they were selected in the plot setup window are listed in a table above the plot e Details Pane The pane on the left shows detailed information about the series and events currently displayed including device information deployment information and series statistics e Graph The plot displays the series and if applicable events selected in the Plot Setup window If you ran the test described in Testing the Logger and Sensors you should see the variances in sensor readings and changes in internal state on the plot Getting Started Using HOBOware with HOBO Data Loggers 19 e Legend The legend to the right of the plot displays t
17. ware Pro from the Onset Website To download HOBOware from the Onset website go to the following URL and follow the instructions for downloading and installing HOBOware http www onsetcomp com products software Installing HOBOware Pro from the Installation CD Windows You must be an administrator to install HOBOware you do not need to be an administrator to run HOBOware once it is installed 1 Insert the CD into the appropriate drive The installation program should start automatically If it does not navigate to the CD drive in My Computer or Windows Explorer and double click HOBOware_ Setup exe to launch the HOBOware installer Note HOBOware for Windows requires the Java Runtime Environment If the correct Java Runtime Environment version is not already installed on your computer the HOBOware Setup program will ask if you want to install it now Click Yes and follow 6 Getting Started Using HOBOware with HOBO Data Loggers the prompts After the Java Runtime Environment is installed the HOBOware installation will continue 2 Follow the prompts to install HOBOware 3 To start HOBOware double click the HOBOware icon on your desktop or select Programs gt Onset Applications gt HOBOware from the Start menu Macintosh 1 Insert the CD into the appropriate drive 2 Double click the CD icon in Finder and then double click the HOBOware pkg to launch the HOBOware installer 3 Follow the instructions on the sc