Home
User Manual
Contents
1. Master function 5 FIXED EQUIPMENT Please fasten the fixture clamp before hanging The clamp can be fasten by the little hole in the middle of the bracket then tie with a safety belt The loading capacity of the safety belt should be 10 times than the weight of the fixture itself 6 CONNECTION OF DMX 512 AND CONNETION WITH THE LIGHT EQUIPMENT Please connect XLR XLR control wire with every light from the output of DMX XLR connection DMX OUTPUT DMX INTPUT Pin 1 Screen Pin 2 Signal Pin 1 Screen Pin 3 Signal Pin 2 Signal Pin 3 Signal ATTENTION Please do remember to connect one circle circuit plug on the output signal of last equipment And this circle circuit plug was connected a 120ohm resistance between terminals 2 and 3 of the CANON plug connect this circle circuit plug can avoid the signal flash www leahualight com phenomena of signal DMX512 during the transmission 5Pins canon socket Pin 1 GND SCREEN 3Pins canon socket Pin 1 GND SCREEN Pin 2 Signal Pin 3 Signal 3Pins canon plug Pin 1 GND SCREEN Pin 2 Signal Pin 3 Signal 5Pins canon plug Pin Pin Pin 4 NC Pin 5 N C 7 Maintenance Problems Check list Trouble Shooting The fixture do 1 If your power as same as the input 1 Make sure the voltage not work of the machine 2 Replace the same fuse 2 If the fuse was broken LED dimmed If your power us same as the
2. LH DO30D 36pcs LED Par Light User Manual LE AHU T REET ENARA GZ LEAHUA LIGHT LIMITED This manual contains important information Please read before operating fixture Add A1 Building The Sixth Industrial Zone Zhu Gang Road Hongxing Shijing Town Baiyun District Guangzhou China Tel 86 020 66292177 Fax 86 020 66292177 1 SECURITY TIPS WARNING To reduce the risk of fire electric shock or injury to persons follow these important safety instructions non professionals not to disassemble the light arbitrarily and lighting accessories inside rated voltage range AC110V 120V 60Hz or AC200V 240V 50HZ to be selected not beam irradiate the flammable materials flammable materials and the lamp should be maintained at least 1M over the distance lamps used in ambient temperature 15 C 40 C the highest temperature of the surface of the lamp 60 C to keep away from the liquid substance and humid environment before using the lights must ensure the good grounding can not install charging and remove any parts the installation of lamps must be fixed screw fasteners with additional security cable and regular inspection lamps consecutive working hours is not recommended more than 10 hours should stop using the lights in time when happens unusual conditions during the process lamp parts of the rotation external accessories and paste parts should be regular inspected such as
3. input Make sure the voltage of the machine input No DMX input 1 If the polarity is opposited in the 1 Correct the DMX DMX controller polarity 2 If it is in DMX mode 2 Change to the DMX 3 If there are 2 Master in a loop mode 3 Set one piece into Slave mode Par Light Set 1 Check if the serial is correct on 1 Set the right serial No works the Par Light display on the single Par abnormality Light www leahualight com 8 AFTER SERVICE 1 Our company offer technical consultation to customers for ever 2 Ifthe machine is wrong and need repairmen please truthfully fill in the related content and feedback us the problems timely as well as we have to improve the product 3 In addition to the lamp also matching accessories are as follows accessories Power line 1 piece Optional parts customers Warranty Card i Name To E p Erodenonp Purchase End User Sale Store Company Name Link man Tel Stamp Add Description These must be truthfully fill seal by the end user and point of sale or else the warranty will not work warranty period and terms see the following warranty period one year since purchase warranty terms 1 If fail when using the product in normal state you can made under the provisions of the warranty show the warranty card and purchase bills copy and enjoy free maintenance service in a specific service center or the manufacturer 2 The following will be the imp
4. lementation of paid service 1 Without the effective warranty card 2 There s blank alter and no point of sale name 3 Fail caused by unresistance 4 Fail caused by transportation or unloading 5 Fail caused by not operate by manual 6 Fail caused by disassemble without unauthorized 7 Fail caused by using the unauthorized control system wwwileahualight com 6 Note Based on our company continue to improve the product the statement containing data may have changed and will not notice the change any more Company retains its right to change specifications related when product is improved Thanks for your understanding www leahualight com 7
5. the emergence of loose and rock should be reinforced in a timely manner to prevent the accident lamps adopt strong winds to refrigerate it is easy to accumulate the dust so you have to clean it weekly especially the cooling air opening otherwise the dust will plug leading to poor light www leahualight com 1 2 TECHNOLOGY REFERENCE Voltage AC110 220V 50 60HZ Power 60w Light source 36pcs led R12 G12 B12 Material Plastic body DMX Channels 6 channel combination optional Inner size 190 140 190 MM N W 0 9KG G W 1 4 KG PCS Carton size 730 410 405mm 20pcs G W 18 6kg www leahualight com 2 3 Board Instruction Digital Par User Manual Au01 Au02 GREEN BLUE RED GREEN RED BLUE Au01 Au07 Au10 Gradual change Sound control leaping change 002 Sound control strobe t00 t00 Auto motor no strobe t01 Auto motor Au08 Au09 Au10 speed from slow to fast P00 P16 r002 RED brightness setting S S Ns nD D gt gt bl bl 1 el amp STO E A A wy gt a Ss S w GREEN brightness setting 002 255 MANE a z z 2 Z EEIEIE Sa as z z HAIE elle J 3 BLUE brightness setting www leahualight com 3 4 DMX CHANNEL SHEET Channel Channel data Function instruction CH1 0 255 Master dimming CH2 0 255 Red dimming CH3 0 255 Green dimming CH4 0 255 Blue dimming CH5 1 255 Strobe control CH6 1 255
Download Pdf Manuals
Related Search
Related Contents
Raidsonic IB-AC643 mounting kit GenX.manual 2/5 1900 Manual de instruções CINTA DE APOIO LOMBAR Begriffe und Abkürzungen - International Commission for the Lightolier LL4MF8LR254 User's Manual Genius Ergo 9000 Genius DX-8500 MaxCube II User Manual Copyright © All rights reserved.
Failed to retrieve file