Home

user manual Geratherm rapid

image

Contents

1. transmis sion Use of the probe cover may result in a 0 1 C 0 2 F difference from actual temperature Dispose of any used probe shield and store the unit in a safe place MEASUREMENT METHODS A It is only is possible to measure temperatures that are above the ambient temperature ORAL Place the probe well under the patient s tongue Instruct the patient to keep their ad mouth closed while the thermometer is reading A normal temperature by this method is usually considered between 36 0 C to 37 5 C 96 8 F to 98 6 F RECTAL If rectal temperature is recommended by your doctor you may use a probe shield In sert thermometer into the probe shield Lubricate the probe cover with a water soluble jelly for easier insertion Do not use petroleum jelly Insert tip of probe no more than 1 5 cm 1 2 inch into rectum STOP if you meet any resistance In general the rectal temperature is around 0 5 C to 1 0 C 1 0 to 2 0 F higher than oral temperature place probe tip AXILLARY Wipe armpit with a dry towel Place probe in the patients armpit and keep the patients arm pressed firm ly against their side In general the axillary temperature is around 0 5 C to 1 0 C 1 0 F to 2 0 F lower than oral temperature Note that in order to achieve better axillary temperature measurement result a minimum measuring time of 2 to 3 minutes is recommended regardless of the beep sound heat pocket A NOTE If you compare tem
2. Medical digital thermometer Geratherm Medical AG GB Geratherm rapid GT 195 1 Germany C 0197 INSTRUCTION FOR USE Please read carefully before using FEATURES 1 Fast oral and rectal temperature measurement in 9 till 15 seconds 2 Easy to read large LCD liquid crystal display 3 This unit is waterproof PARTS DESCRIPTION Sensor C Display window ON OFF Button SPECIFICATION Range 32 0 C to 43 9 C 90 F to 110 F Below 32 0 C 90 F displays L C F Above 43 9 C 109 F displays H C F Intended use Measurement of body temperature Resolution 0 1 C F Accuracy 0 1 C 34 0 C to 42 0 C 0 2 C other ranges 0 2 F 93 2 F to 10 6 F 0 4 F other ranges Display Liquid crystal display 3 digits Battery included Micro Alkaline battery 192 LR41 1 55 V Power Consumption 0 15 milliwatts in measurement mode Battery life More than 200 hours of continuous operation IP classification IP 27 Protected against solid foreign objects with a diameter of 12 5 mm and protec tion against temporary immersion Dimensions 135 mm x 23 2 mm x 12 mm Weight Approx 15 grams including battery Beeper Approx 8 second sound signal when no relevant increase in temperature is detected Memory Built in memory enabling display of previously measured value Working Conditions Temperature 10 C to 40 C 50 F to 104 F Humidity 15 to 95 R H It is only is possible
3. and in this time there may possibly be a further slight increase in the temperature shown After that the maximum temperature measured is recorded and stored it remains visible on the LCD display for 3 minutes until the ther mometer is automatically switched off Or short press the ON OFF button to switch off directly 7 The unit will automatically turn off in 3 minutes approx However to prolong battery life it is best to turn off the thermometer once the temperature has been noted SPECIAL FEATURES Last Memory Recall When the ON OFF button is depressed to activate the thermometer hold down for approxima tely 2 seconds The display of 188 8 will change to show the last measured temperature This reading is displayed as long as the button is held down When the button is released the thermometer will be in ready to measure mode and the recalled temperature will be erased Fever Indicator If the temperature registers higher than 37 5 C 99 5 F the fever indicator a quick beeping sound which occurs continuously for about 8 seconds will sound when the peak temperature has registered Switch between Centigrade and Fahrenheit After turning on the thermometer press and hold ON button for 2 se conds In order to store the desired unit of measurement C or F it is necessary to conduct a complete measuring procedure Note You may puta sanitary plastic probe shield on the sensor tip to help prevent avoidance of virus
4. inst manufacturer s defect under normal household use Following the directions closely will ensure years of dependable operation If the thermometer does not function properly first check the battery see battery replacement instructions We recommend that the accuracy of the unit be checked every 2 years by an authorised laboratory in Germany this is compulsory Replace it if necessary SYMBOL INDEX Follow instructions for use Type BF applied part 95 P Store between 15 and 95 RH Caution Read the instruction aal manual 55 C o Batch code Geratherm Medical AG a a OT mm yyyy month year Fahrenheitstrasse 1 f 98716 Geschwenda The device must not be disposed of German with household waste y www geratherm com 25
5. mance may be degraded 8 Stop using the thermometer if it operates erratically or if the display malfunctions 9 If the thermometer has been stored at below freezing temperatures allow the thermometer to warm naturally to room temperature before using BATTERY REPLACEMENT 1 When the symbol J appers the battery needs to be replaced 2 Remove the battery cover from the thermometer and then remove the black rubber 3 Use a toothpick or the like to pry loose the battery cover and the old battery 1 Avoid using any sharp metal object in this operation 3 4 Place a new battery into the battery holder O 5 Replace and fasten the battery cover securely 2 Discard old battery carefully out of reach of young children Do not dispose of the battery in a fire It may explode HOW TO USE 1 Disinfect the probe with ethyl rubbing alcohol before using Maggs pags Depress the ON OFF button The display will read QJ GI0 m or Wi Imt M 2 3 Release the ON OFF button and the display will show L C or L F with C or F flashing 4 Place the probe in the appropriate position oral rectal or axillary 5 As soon as the thermometer does not register any further relevant increase in temperature C stops flashing and the maximum value measured up to that time is shown accompanied by a series of audible signals 6 The thermometer continues measuring the temperature for a further minute after the audible signals begin
6. peratures between two thermometers it is possible to have two different readings even if both thermometers are within their accuracy tolerances Differences in how you take each reading and the thermometer s tolerance range can account for nearly 0 1 C 0 2 F variability REMEMBER Find your normal temperature and watch for changes CLEANING AND DISINFECTION l For household use always clean the probe head before and after each use Wash the tip with a solution of mild detergent and cool water Disinfect the thermometer by wiping the sensor and lower stem with a cloth dipped in a household antiseptic solution such as rubbing alcohol recommendation 70 isopropyl alcohol The thermometer is water resistant Do not boil or clean in autoclave DISPOSAL Observe the applicable regulations when disposing of the thermometer and batteries This thermometer must not be disposed of together with domestic waste All users are obliged to hand in all electrical or electronic devices regardless of whether or not they contain toxic substances at a municipal or commer K cial collection point so that they can be disposed of in an environmentally acceptable manner Please remove the batteries before disposing of the thermometer Do not dispose of old batteries with your household waste but at a battery collection station at a recycling site or in a shop LIMITED WARRANTY This thermometer is guaranteed for two years from the date of purchase aga
7. to measure temperatures that are above the ambient temperature Storage Conditions Temperature 25 C to 55 C 13 F to 131 F Humidity 15 to 95 R H Guarantee of Quality EN 12470 3 Clinical thermometers Part 3 Performance of compact electrical ther mometers with maximum device Geratherm is certified in accordance with Council Directive 93 42 EWG and EN ISO 13485 and is entitled to affix the CE mark C 0197 Notified Body T V Rheinland LGA Products GmbH Electromagnetic compatibility EMC The present medical product is a device with extremely high degree of noise immunity Therefore the enclosure with the EMC tables was not printed out A GEESE 1 Use of this instrument is not intended as a substitute for consultation with your physician Prolonged high fever requires medical attention especially for your children Please contact your physician 2 Child s temperature shall be taken under adult s surveillance 3 Keep out of the reach of unsupervised children Choking resulting from a child swallowing a small part that has become detached from the thermometer 4 Do not boil bite bend drop or disassemble this thermometer 5 Do not attempt to disassemble the unit except to replace the battery 6 Avoid taking temperature in 30 minutes after physical exercises bathing or dining 7 Do not store use and transport the unit under direct sunlight at a high temperature or in high humidity or dust Perfor