Home
590 & 591 User Guide
Contents
1. esses 20 LED Display Glossary seeeeeeene 21 System Attributes 23 Service Record 3 2 de A a decns 23 User Ghatt IEA Ub ini Aus 24 ACE Instructions ee cce ere 25 Programming ACE Keyfobs onto your System 26 Technical Manuals Online http4Awww tech man com User Manual GARDTEC 590 591 Introduction Two types of display variation are available LCD giving two rows of 16 character English text and may be used on the Gardtec 591 and LED giving two 7 segment LED digits that may be used on the Gardtec 590 amp 591 Please take time to familiarise yourself with the type of equipment fitted to your premises as it will prove invaluable whilst using this manual User Code Types Four types of User Codes are available on the Gardtec 590 591 each user code type allows for different levels of access In total 7 User codes may be programmed by a Master Level User Code User number 1 will always be a Master Level User but the remaining 6 User Codes may be programmed by a Master Code to the required level of access These may be changed at any time via a Master level code The User Code levels available and the functions available for the levels are 1 Set Only Only Allows for the setting of the system 2 Main User Allows Setting Part Setting Zone Remove if programmed by engineer System Test Unsetting Reset after Alarm if programmed by engineer 3 User Allows Set
2. Technical Manuals Online http4Awww tech man com User Manual GARDTEC 590 591 Changing The Chime Status Master code only The Chime zones will have previously been programmed by the installation company A Master level code may change the status of the Chime between On and Off To do so proceed as follows 1 With the display showing lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 2 Enter a Master Code the display will Pe o you want to show for example Set 3 Press NO four times the display will show Do you want to Change Chime 4 Press YES the display will show for example Chime is Off ok Or Chime is On ok 5 Press NO to change the status of the Chime Do you want to then press YES the display will show Change Chime 6 Press 0 to escape the display will show lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 Technical Manuals Online http 4Awww tech man com GARDTEC 590 591 User Manual Programming User Codes Master code only 1 With the display showing lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 2 Enter a Master Code the display will show EX DNI User Names on 816 amp 840 Only Set 3 Press NO five times the display will show Do you want to Prog USER CODE
3. Press NO seven times the display will show Do you want to Access Remote Press YES the display will show Please WAIT Until Dialling commences Then Please WAIT Dialling Until Connection Then Please WAIT Connect When your installation company has finished the display will show lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 In the event of any errors the display will show MT TERROR 111 Try Again Technical Manuals Online ht g www tech man com User Manual GARDTEC 590 591 Resetting After an Alarm Your installation company will have programmed the reset modes for your system so that it complies to your insurance company and legislation requirements Your installation company will have informed you as to the type of reset that your System is set for Before attempting to reset your system ensure that the system is Un set 1 If the system is programmed for any code reset enter a user followed by YES if Master or Main code is used the exit tone will sound and the display will show for example EXIT Now All Zones ON 15 2 Enter the code again to abort the setting 3 The system is now reset Or If a higher level of code is required one of the following displays will be shown Can t Set Use Use a Master cod
4. GARDINER TECHNOLOGY GQARDIEG 590 591 LCD User Instructions amp LED User Instructions GARDTEC 590 591 User Manual Contents Using LCD Keypads INTRODUCTION x iie ie eere NES 2 User Code Types eene 2 Setting The System eesssssseeeeeee 3 Unsetting The System sese 3 Part Setting The System sess 4 Removing Zones sees 5 Testing The System sssseeeeee 6 Viewing The Event Log eeem 7 Changing The Chime Status 8 Programming User Codes ssseee 9 Programming Time amp Date ienee 10 User Initiating Remote Access eessesse 11 Resetting After An Alarm eeeeeee 12 Resetting After Mains Failure esses 13 Using LED Keypads sees 13 Setting The System sse 13 Unsetting The System see 14 Part Setting The System esses 14 Area Setting once ueri iiem 15 Removing Zones esee 23 Testing The System ssssseeee 16 Viewing The Event Log eee 17 Changing The Chime Status 18 Programming User Codes eees 18 User Initiating Remote Access sssessss 19 Resetting After An Alarm ecese 20 Resetting After Mains Failure
5. S 4 Press YES the display will show Enter User No 1 7 displayed on 800 amp 816 1 7 Then YES 5 Enter the user number 1 to 7 that you wish to program followed by YES the display will show Now Enter Code T Then YES 6 Enter the code you require codes may be 4 5 or 6 digits followed by YES Entering 000000 will delete an existing code Note If the code already exists or is a duress of another code an error will be shown choose another code and return to step 6 7 The display will show Choose Type a O XXXXXX 1 XXXXXX not if user 1 is being programmed The display will scroll showing the code types available see user types or display 8 Enter the required type followed by YES Do you want to the display will show Prog USER CODES 9 If you wish to program other User Codes return to step 4 Or Press 0 to return to lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 Technical Manuals Online httpj4nqvw tech man com User Manual GARDTEC 590 591 Programming Time amp Date 1 With the display showing lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 2 Enter a Master Code the display will show Do you want to User Names on 816 amp 840 Only Set 3 Press NO six times the display will s
6. a stand alone unit control is via neat remote keyfob s We strongly advise that User Number 1 is not used for ACE in order that the user retains control of the programming functions P 1 Point the keyfob at the ACE receiver and press the button Setting the System with ACE 2 When the exit tone sounds exit the premises in the usual way Part Setting the System with ACE 1 Point the keyfob at the ACE receiver and press the button 2 When you hear the exit tone press the keyfob button again within 3 seconds for Part Set 1 or Press 1 2 or 3 on the receiver keypad for the Part Set you require Unsetting the System with ACE 1 Enter the premises via an authorised entry point 2 Point the keyfob at the receiver and press the button Technical Manuals Online ht amp ps www tech man com User Manual GARDTEC 590 591 Programming ACE Keyfobs onto your System Two modes are available for ACE these are Normal amp High Security Please check the User Information Chart on page 2 noting the mode of your ACE control Normal Security In this mode up to fourteen keyfobs may be programmed onto a single user number 1 Follow the procedure for programming user codes to the point when the user code is entered 2 Point the keyfob at the ACE unit and press the button on the fob 3 Repeat this procedure for any other fobs you wish to be programmed using the same user number each time e g User 1 or User 2 et
7. ay will show Enter Zone No then YES or NO 6 Repeat step 5 until you have removed all the required zones 7 Press 0 to escape the display will show Do you want to Set 8 Press YES the continuous exit tone will sound 9 Exit the premises via the authorised exit route the exit tone will change as detectors are violated When the premises are secure listen that the exit tone returns to the continuous tone Wait until the exit tone finishes before leaving Note Zone remove is only effective for the one set Technical Manuals Online http 4Awww tech man com User Manual GARDTEC 590 591 Testing The System Master amp Main codes only 1 With the display showing lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 2 Enter a Master or Main level code the display will show m want to User Names on 816 amp 840 Only 3 Press NO the display will show Do you want to REMOVE Zones 4 Press NO the display will show Do y wantto TEST the System 5 Press YES the display will show 1 Status 4 Strobe for 3 seconds 6 Sounder 9 Bell Then for example All Zonas OK gt TESTING 6 Pressing 1 will enter zone Status mode All zones will show on the display and will be deleted as each zone is triggered Press 0 to escape Pressing 6 will silence the internal so
8. c each time 4 If more than one ACE receiver is fitted fobs need to be programmed onto all ACE receivers yet again the same user number should be used Note When programming the fob onto more than one receiver on the same system the button on the fob MUST be held down continuously between programming onto the first and subsequent ACE receivers High Security In this mode each keyfob will occupy a User number The number of keyfobs that may be used is limited by the maximum number of user codes available on the system up to a maximum of fourteen 1 Follow the procedure for programming user codes to the point when the user code is entered 2 Point the keyfob at the ACE unit and press the button on the fob 3 Repeat this procedure for any other fobs you wish to be programmed using a different user number each time e g User 1 or User 2 etc each time 4 If more than one ACE receiver is fitted fobs need to be programmed onto all ACE receivers retaining the same user number for each individual fob Note When programming the fob onto more than one receiver on the same system the button on the fob MUST be held down continuously between programming onto the first and other ACE receivers Note In all cases when the ACE is used only Master amp Main user levels will allow part setting via the keyfob Other code levels will only allow part setting in conjunction with the keypad Technical Manuals Online ht amp ps www tec
9. e to reset the system Master Code Or Can t Set Use Call the installation company ENGNR Code Or Can t Set Use ENG Anti Code 1234 Call the installation company and quote the number given Or Can t Set Use Anti Code 1234 Technical Manuals Online ht amp ps www tech man com GARDTEC 590 591 User Manual 4 To reset the system with an anti Code contact the central station or engineer as instructed by the installation company and quote the source given by the display 5 The central station or engineer will give a return Anti Code this may contain the YES amp NO keys for example 5 YES 2 4 6 Enter this Anti Code into the keypad 7 The system is now reset Resetting After Mains Failure After a mains failure the user will have to enter his her code twice in order to operate the system Using LED Keypads This section is dedicated to using LED keypads Twin Seven Segment Setting The System 1 With the display showing Un 2 Enter the User Code followed by YES if Master or Main type code has been used 3 The display will show E z and the exit tone will sound Exit the premises via the authorised exit route the exit tone will change if any detectors are violated during exit 4 Once the premises are secure listen that the exit tone returns to the continuous tone 5 Wait until the exit tone finishes before leav
10. h man com GARDINER TECHNOLOGY Gardiner Technology Ltd Queensway Rochdale Lancashire OL11 1TQ United Kingdom Internet http www gardiner technology com e mail sales gardiner technology com 168X cs 3BSIA Hai seem etim ee INVESTOR IN PEOPLE Uenificae Io 1359 Teebsscal Manuals Online http www tech man com
11. hing 4 Press YES the display may show for example R Lthis is the most recent event 5 Whilst viewing the Log Pressing NO will move back to the previous event Pressing YES will move forwards to the next event Pressing 7 will take you back to the first event of the previous day Pressing 9 will take you forwards to the first event of the next day Pressing 3 will display the Date Time in the format Day of month two digits Month two digits Hour two digits Seconds two digits 7 When you have finished viewing the Log press 0 twice to return to the Unset condition Note Acomplete list of possible LED displays is given in the section LED Display Glossary Technical Manuals Online ht amp pg www tech man com User Manual GARDTEC 590 591 Changing The Chime Status Master code only The Chime zones will have previously been programmed by your installation company A Master level code may change the status of the chime between On and Off To do so proceed as follows 1 With the display showing U n enter a Master code 2 The display will show 5 E flashing 3 Press NO four times the display will show E h 4 Press YES the display will show o F or an 5 Press NO to change the Chime status 6 When you have finished press 0 twice to return to the Unset condition Programming User Codes Master code only Please refer to pages 2 amp 34 for details of codes already programmed onto your syste
12. how Do you want to Set DATE TIME 4 Press YES the display will show Enter Day Month Then YES 5 Enter the Day Month ie 0706 for 7th June followed by YES The display will show Enter Hrs Mins Then YES 6 Enter the time using 24Hr Clock ie 23 30 for j i 2 Do you want to 11 30pm followed by YES the display will show BC DATE TIME 7 Press 0 the display will show lt lt lt lt UN SET gt gt gt gt 07 Jun 23 30 02 Technical Manuals Online hiig g4www tech man com GARDTEC 590 591 User Manual User Initiating Remote Access Optional Access Remote allows your installation company to examine your system and re program system settings as you need the changes without the need for an engineer to visit your premises If your system has remote communications fitted your installation company may have programmed the system so that you initialise the Access Remote call usually on lines with incoming calls barred To initiate the Remote Call follow the instructions below 1 2 Note Negotiate with your installation company when you should initiate the Remote Call With the display showing ccc UN SET 01 JAN 18 58 01 Enter a Master Code the display will show Do you want to User Names on 816 amp 840 Only Set
13. ing Technical Manuals Online ht g www tech man com GARDTEC 800 Series GARDTEC 590 591 Unsetting The System Enter the premises via the authorised entry route the broken entry tone will sound Proceed to the keypad enter a valid user code the display will show U n The system is now Unset Part Setting The System using Master amp Main type codes 1 2 With the display showing U n Enter a Master or Main type code The display will show 5 E flashing Press 1 2 or 3 for Part 1 2 or 3 the display will show the E and The two bottom bars if Part 1 has been selected The top and bottom bars if Part 2 has been selected The bottom bar only if Part 3 has been selected The exit tone may or may not be heard dependant on the system settings Exit the premises or retire to an unprotected part of the system At the end of the exit time either the exit tone will stop or a single beep will be emitted dependant on system settings Technical Manuals Online ht amp ps www tech man com GARDTEC 590 591 User Manual Removing Zones Master amp Main codes only If programmed by the installation company individual zones may be removed this may only be done by a Master or Main level of code 1 With the display showing U n Enter a Master or Main level code 2 The display will show 5 E flashing press NO 3 The Display will show FE flashing press YES 4 The display will show F 5 Enter the zone nu
14. m 1 With the display showing U c enter a Master code 2 The display will show 5 E 3 Press NO five times the display will show U c flashing 4 Press YES the display will show U 5 Enter the User number you wish to program 1 to 7 for 800 followed by YES 6 The display will show E o Enter the required code 4 5 or 6 digits followed by YES Entering 000000 will delete an existing code 7 The display will show F enter the code type from the following list followed by YES Code Types may be seen at the beginning of this manual Technical Manuals Online ht amp ps www tech man com GARDTEC 590 591 User Manual 9 If you wish to program other User codes return to step 4 Or To return to the Unset condition press 0 Programming Date amp Time Note When using LED keypads the Date amp time will only be displayed when the 3 key is pressed whilst viewing the Log 1 With the display showing U n enter a Master code 2 The display will show 5 E 3 Press NO six times the display will show d F flashing 4 Press YES the display will show d enter the day and month followed by YES e g 0706 for 7th June 5 The display will show F enter the time using the 24Hr clock followed by YES e g 2330 for 11 30pm 6 The display will show d F flashing 7 If you wish to re program the time return to step 4 Or To return to the Unset condition press 0 User Initiating Remote Access Users should only ini
15. mber you wish to remove followed by YES 6 The display will show F 7 If you wish to remove other zones return to step 5 Or To escape press 0 the display will show 5 E flashing 8 Press YES to start setting the system 9 Exit the premises or retire to an unprotected part of the system At the end of the exit time the exit tone will stop provided the system was clear Note Zone remove is only effective for the one set Technical Manuals Online ht g www tech man com User Manual GARDTEC 590 591 Testing The System Master amp Main codes only With the display showing U n Enter a Master or Main level code the display will show 5 E flashing Press NO twice the display will show F E flashing Press YES the display will show F R press YES if you wish to test all areas or press NO until the area you wish to test is displayed then press YES The display will show FE if all zones are clear Whilst in test mode Pressing 6 will silence the internal sounders Pressing 4 will toggle the strobe On Off Pressing 9 will toggle the Bells On Off When you have finished testing the system press 0 twice to return to the Unset condition Technical Manuals Online ht amp ps www tech man com GARDTEC 590 591 User Manual Viewing The Event Log Master code only 1 With the display showing U n enter a Master code 2 The display will show 5 E flashing press NO three times 3 The display will show L a flas
16. on the display call the installation company or central station for an Anti Code and proceed as shown from step 4 4 To reset the system with an Anti Code enter the number given by the central station or installation company into the keypad this may contain the YES amp NO keys 5 The system is now reset Resetting After Mains Failure After a mains failure the user will have to enter his her code twice in order to operate the system Technical Manuals Online ht amp ps www tech man com GARDTEC 590 591 LED Display Glossary Displays During Normal Use Un System Unset Ez The system is full setting The system is fully set Ez The system is part 1 setting z The system is part 1 set E The system is part 2 setting z The system is part 2 set E The system is part 3 setting E The system is part 3 set RL An alarm has occurred press NO to view Fb Fuse blown or battery volts low ec b Control box tamper eb b bell box tamper PL Telephone Line fault or coms fail Pc Power Cut er Tamper keypad 4 may show 1 to 4 Er Reset is required by a higher level code or an error has 5E FE FE Ch Uc dk Lo ud En En User Manual occurred whilst programming Reset by Anti Code is required flashing Do you want to Set Remove zones Test system Change Chime Program User codes Program date time Log Waiting for numeric input Wait system in use Engineer code
17. reset required flashing Call Engineer Technical Manuals Online ht amp ps www tech man com User Manual GARDTEC 590 591 Displays Whilst Viewing Log oY 04 B 4 d 3 rE Rr DI Fe Re Pe FF rL Alarm occurred because of zone 4 was activated Alarm occurred because of tamper on zone 4 flashing zone 4 was removed Telephone Line restored Power restored Duress code by user 3 Watchdog reset Alarm was reset bells on User code 1 used may show 1 to 47 Fire activated from alert keys on keypad 2 Alert activated from alert keys on keypad 2 Panic activated from alert keys on keypad 2 A zone on test has failed read Log Technical Manuals Online ht amp ps www tech man com GARDTEC 590 591 User Manual System Attributes ZoneNo Zone Type Location Part Info Front Door 1 amp 2 Service Record Date Comments Signature Alarm Reset Type Tamper Reset Type Technical Manuals Online ht amp gswww tech man com User Manual GARDTEC 590 591 User Chart Please use this chart to indicate what user names have been programmed onto your System and those that are in use User Notes Technical Manuals Online ht amp ps www tech man com GARDTEC 590 591 User Manual ACE User Instructions ACE Advanced Control Equipment allows control of your Gardtec 590 591 system via Infra Red Remote control Ace is available built in to a range of keypads or as
18. tiate Remote Access when instructed to do so by the installation company 1 With the display showing U n enter a master level code then press NO seven times the display will flash R F 2 Press YES the display will show bu Wait then d t Dialling then E n Connected 3 When the installation company has finished the display will return to U n Technical Manuals Online ht amp ps www tech man com User Manual GARDTEC 590 591 Resetting After An Alarm Your installation company will have programmed the reset modes for your system so that it complies to your insurance company and legislation requirements Your installation company will have informed you as to the type of reset that your System is set for Before attempting to reset your system ensure that the system is Un set 1 If the system is programmed for any code reset enter a user followed by YES if Master or Main code is used the exit tone will sound and the display will show for example E z 2 Enter the code again to abort the setting 3 The system is now reset Or If the display shows Er when you attempt to reset it refer to the programmed reset mode and take the appropriate action as follows Reset Type Action Master Code Use a Master code to set and abort setting Engineer Code Call the installation company Engineer Anti Code Call the installation company Anti Code When you try to set the system make a note of the four digit number given
19. ting Part Setting Reset after Alarm if programmed by engineer Unsetting 4 Master Allows Setting Unsetting Zone Remove if programmed by User 1 always Master engineer Test System View Log Chime On Off User Codes Set Time Date Reset After Alarm if programmed by engineer Unsetting Technical Manuals Online http4Awww tech man com GARDTEC 590 591 User Manual Setting The System This section is for systems fitted with LCD keypads for LED keypads please refer to page 13 1 With the display showing lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 Enter the User code followed by YES if Master or Main type code has been used The display will show EXIT Now and a continuous exit tone will sound All Zones ON 15 Exit the premises via the authorised exit route the exit tone will change if any detectors are violated during exit Once the premises are secure listen that the exit tone returns to the continuous tone Wait until the exit tone finishes before leaving Unsetting The System 1 Enter the premises via the authorised entry route the broken entry tone will sound proceed to the keypad At the keypad enter a valid code the display will show lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 The system is now unset Technical Manuals Online http4Awww tech man com User Manual Part Set
20. ting The System using Master amp Main type codes 1 With the display showing Enter a Master or Main type code the display will show for example Press 1 2 or 3 for Part 1 2 or 3 the display will show for example The exit tone may or may not be heard dependant on the system settings Exit the premises or retire to an unprotected part of the system At the end of the exit time either the exit sounder will stop or a single beep will be emitted dependant on system settings GARDTEC 590 591 lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 Do you want to Set EXIT Now Part 1 15 Technical Manuals Online http4Awww tech man com GARDTEC 590 591 User Manual Removing Zones Master amp Main codes only If programmed by the installation company individual zones may be removed this may only be done by a Master or Main level of code 1 With the display showing lt lt lt lt UNSET gt gt gt gt 01 JAN 18 58 01 2 Enter a Master or Main level code the display will show Do you want to Set 3 Press NO the display will show Do you want fai REMOVE Zones 4 Press YES the display will show Enter Zone Nonas then YES or NO 5 Enter the zone number you wish to remove followed by YES pressing NO will un remove a zone the displ
21. under Pressing 4 will toggle the Strobe On Off Pressing 9 will toggle the Bell On Off 7 Whilst in Test mode any zones violated will sound the internal sounder if it has not been silenced and show on the display 8 When you have finished testing the system press 0 twice the display will show lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 Technical Manuals Online http4nqvw tech man com GARDTEC 590 591 Viewing The Event Log Master code only User Manual 1 With the display showing UN SET 01 JAN 18 58 01 2 Enter a Master Code the display will show for example Do you want to Set Do you want to View the LOG 3 Press NO three times the display will show 4 Press YES the display will show for 3 seconds While Viewing 1 Printer On Off Then for example Read Log 01 JAN 18 58 01 5 This is the most recent event in the log Whilst viewing the Log Pressing NO will move back to the previous event Pressing YES will move forward to the next event Pressing 7 will take you back to the last event of the previous day Pressing 9 will take you forward to the first event of the next day 6 When you have finished viewing the Log press 0 twice the display will show lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01