InDTU300 series User`s Manual
Contents
1. Local COM2 E Work o Dialup lup Number PPP Heartbeat Interval s Redial Interval Center Link Policy Others IEC 101 Settings Device Manager Admin Access ICMP Settings Custom UDP Physies COM Settings COM Select Coma vl PC Time DTU Time Current User Advanced fe None 1 v Connecting Devices Enabling Services inori ORGIA I 001 Connecting Devices Enabling Services 2012 5 3 19 08 36 1970 1 1 12 44 40 Admin Sync Time Logout Restore to Detaut Write Conf File Read Conf File Save Conf File Load Conf File Read Log irmware Upgrade oe oeteetoru download GPRS settings Auto Dialup YES Dialup Number 99 1H APN cmnet Username GPRS Password GPRS PPP Heartbeat Interval s 50 Open Port COM4 Detect device success Data 55 AA 55 AA 03 00 00 11 65 Total frame length 9 TLVs length 0 Receive 18 byte datas AA 55 AA 55 03 00 09 81 2A 00 05 31 63 38 30 31 BF FD Baudrate 115200 DataBit 8 Parity N StopBit 1 5 Open Port COM4 2 Detect device success Beijing InHand Networks Technology Name Defalut Ver INDTU3XX STD V1 1 37 Jul 5 2011 19 13 44 6 Click Data Center to configure the details of where InDTU300 send data to sr Z S El Configuation i Local COM1 Local COM2 Center IP IEC 101 Settings Device Manager Admin Access ICMP Settings Custom UDP
2. 2 SIM Card Installation Slide and open the upper cover as shown in above picture insert the SIM card into the slot properly Then slide back the upper cover to close the housing 3 Antenna Installation Put the enhanced antenna s connector into the antenna opening on the housing screw tightly Place the amplifier of the enhanced antenna at a place where it can receive GPRS CDMA signal InHand Networks EE Connecting Devices Enabling Services 2 1 2 Power Supply Support 5 35V DC power input ripple wave is smaller than 100mV Connect anode of the DC power to V terminal cathode to V terminal 2 1 3 Check Network Connection After the SIM card is put in and antenna is installed connect the power cord of INDTU332 to a power supply make sure it is connected properly and then switch on INDTU332 If the MODULE LED flashes the indication of On Off Flash will differ by the module it indicates a network has been found Refer to Section 4 3 for LED indications 2 2 Software Installation To deploy a complete remote monitoring system the user needs to install corresponding software on the centre or develop own centre software with the development kit we provide If applied InHand private protocol InHand can provide the necessary testing tool please check in the tool kit for it You can use the InDTU configuration tool to configure InDTU332 Please check in the tool kit InHand Networks 2 wwwinhandnetworks
3. 1 3 Product Features 1 3 1 Hardware Features INDTU300 series works on the GPRS CDMA data communication system a GPRS CDMA module is integrated in the hardware system to provide reliable communication with GPRS CDMA mobile network The hardware is constructed with high performance MPU and peripheral FLASH enabled powerful processing capability By supporting multiple standards of industrial bus it also has good extendibility The INDTU300 series have been widely used in remote and on site data collection remote monitoring and on site control in different industries Below is an illustration of the hardware structure of INDTU300 InHand Networks P wwwinhandnetworksicom Connecting Devices Enabling Services Connecting Devices Enabling Services RS232 INDTU System architecture C CDMA CPU Processor Configuration ommumcaton i face module RS232 422 485 Indicato External Communication Intertace Hardware Structure of InDTU300 Key features gt Exquisite look with fast installation design gt Moisture proof and anti interference design gt Industrial grade wide voltage range 5 35V DC gt Industrial grade temperature range 20 C 70C 1 3 2 Software Features INDTU300 products realize wireless data communication between serial devices at remote control stations and the central control system The main functions of INDTU300 are listed in Table below InHand Networks P wwwinhandnetw
4. Generally should set to open so in the Connect On Demand mode any incoming phone call will trigger InDTU300 to connect to the network Trigger by SMS open close If set to open in the Connect On Demand mode any incoming short message from DM will trigger INDTU300 to connect to the network Trigger by COM Data open close Generally should set to open so in the Connect on Demand mode any incoming data through the local serial port will trigger INDTU300 to connect to the network Timing Active Interval m Time interval to reconnect to the network whenever after INDTU300 enters sleep mode value range is between 071440 Timing Offline m Time interval to get offline and restart value range is 0760 If the value is O the interval is infinitely long Usually should set to 0 Device Data Control Flow Yes Note When set to Connect on Demand mode please at least turn on 1 of the 3 trigger mechanisms 3 2 4 GPRS CDMA Settings Auto Dialup on off On dialup automatically after configuration Off dialup on demand triggered by SMS Call Serial Data Dialup Number default 99 1 provided by local mobile operator APN Username Password provided by local mobile operator PPP Heartbeat Interval the heartbeat to keep link alive Redial Interval when ppp dialup failed after this interval INDTU300 will redial MAX Retries after MAX Retries and no dialup successful INDT
5. pointed to by the IP Address and Port Number of the Data Center configured in INDTU300 When registered successfully INDTU300 is ready for data transmission between serial devices and the data center Function of INDTU300 InDTU300 functions as the communication bridge between serial devices e g RTU PLC etc and the data center package the serial data from serial device sending to INDTU300 into network data pack and delivering to the data center and delivering the serial data from data center to serial devices through the serial port 4 1 DC Mode Introductions We provide a development kit demo to user which is a simple developable application program allowing the user to develop and expand For the function and usage of API please refer to IHDC Development Help Document After development is completed run the program and monitor the service port through which InDTU300 transmits data to and from the center We also provide the corresponding test software GPRS demo 4 2 Link Mode 4 2 1 Always Online To use the Always Online mode set the parameters of INDTU300 as below Link Mode Always Online InHand Networks Connecting Devices Enabling Services Trigger by Call Open or Close Trigger by COM Data Open or Close Timed Active Interval m O Timed Offline O Divide Data Control Flow Yes In the Always Online link mode INDTU300 keeps staying online and will auto redial whene
6. prompt then you can continue your operations if not you have to check your connection and serial parameters again 2 Then there ll be a window display you should input adm 123456 to login InHand Networks E Configuation Local COM1 i Frame Size Byte E Local COM2 i Frame Size Byte H Work Mode E GPRS settings Auto Dialup a Dialup Number PPP Heartbeat Interval s Redial Interval ORGIA 1001 Connecting Devices Enabling Services Physies COM Settings COM Select COM4 v PC Time 2012 5 8 18 44 33 TR Sync Il Baudrate 115200 7 Auto DTU Time 1970 1 1 12 20 40 Advanced f None 1 y Current User Logout Restore to Default Write Conf File irmware Upgrade e o gt z awe adm Ea Cancel Serial Stop Bi es HEN Serial Check Serial Scan Interval 100ms 2 Serial Timeout 5 Read Conf Fie Save Conf Fie Load Cont Fie Read Log Local COM2 Baud Rate 118 Serial Data Bi StopBit 1 5 Open Port COM4 Detect device success Data 55 AA 55 AA 07 00 00 70 06 Total frame length 9 TLVs length 0 Receive17 byte datas AA 55 AA 55 07 00 08 81 12 00 04 00 00 3C FA A5 55 Got device time succes Data 55 AA 55 AA 07 00 00 70 06 Total frame length 9 TLVs length 0 Receive17 byte datas AA 55 AA 55 07 00 08 81 12 00 04 00 00 3D 18 61 88 Got device time succes Beijing InHand Networks Technology Nam
7. serial port Export and save the configuration of Configuration INDTU300 or import the backup configuration file into INDTU300 Read with the i Store key device log in the flash configuration O p memory program or control Advanced panel Functions A Issue configuration SMS trigger and Import Export Device Manager remote upgrade commands from DM Function platform management device l This function requires Remote telnet with InDTU300 to check TCP a SIM card that can the operation status read device log Function get a public network and remote upgrade a InHand Networks gt wewncirhandnetworks com Console Convenient for remote debugging of Allow TCP client to connect to user s equipment TCP Server Function INDTU300 Now InDTU300 and the TCP This function requires client form a bridge a SIM card that can get a public network IP This function need a SMS modem INDTU can serve as a SMS modem oe special firmware 1 4 Technical Parameters 1 4 1 Standard Parameters Function Description Support GPRS CDMA network realize wireless data communication between remote serial devices and central control system RS232 RS485 SMA 50 Q Working Voltage 5 35VDC Working Current Standby 12mA 12VDC Communication 45mA 12VDC Peak Consumption 100mAQM12VDC Notes Above data is the test result in a particular network In different networks standby current ranges between
8. 01 Connecting Devices Enabling Services Physies COM Settings COM Select COM4 te PC Time 2012 5 9 18 00 11 Baudrate 115200 y Auto DTU Time 1970 1 2 11 36 31 Advanced 8 None 1 X Current User Admin Restore to Default Write Conf File Read Conf File Save Conf File Load Conf File irmware Upgrade Sync Time Should be consistent with the center MAX 11 Bits 2012 5 9 18 00 01 Data 55 AA 55 AA 07 00 00 70 06 2012 5 9 18 00 01 Total frame length 9 TLVs length 0 2012 5 9 18 00 01 Receive17 byte datas AA 55 AA 55 07 00 08 81 12 00 04 00 01 84 3F 76 6A 2012 5 9 18 00 01 Got device time succes Start downloading configuations Data 55 AA 55 AA 01 02 1D 00 01 00 08 2A 39 39 2A 2A 2A 31 23 00 02 00 05 63 6D 6E 65 74 00 03 00 04 47 50 Total frame length 550 TLVs length 541 Download configuations complete Receive589 byte datas AA 55 AA 55 81 02 44 81 0A 00 04 30 30 30 30 00 01 00 08 2A 39 39 2A 2A 2A 312300 Current SN is DG3321109002990 SN could not be changed E j 4 MA O fm anc 2 5 39 18 00 09 CRC done Beijing InHand Networks Technology Name Defalut Ver INDTU3XX_STD_V1 1 37 Jul 5 2011 19 13 44 8 You should reboot InDTU300 after write conf file Until now the configuration is complete 5 2 InDTU300 as a SMS modem INDTU300 series can serve as a SMS modem You just set Max Re link interval as troy in Center Link Policy directory The INDTU300
9. 8 14mA QM 12VDC communication current ranges between 35 55mA 12VDC TT de LOOOMA 12VDC Supply agnos tele JANE Ta elt 40 C 85 C Temperature Working Humidity 5 95 non condensing InHand Networks P wwwinhandnetworksicom Connecting Devices Enabling Services Connecting Devices Enabling Services 1 4 2 Serial Ports Port Type RS232 or RS485 Data Bit 8 Stop Bit 1 Check Bit N O E Baud Rate 1200 2400 4800 9600 14400 19200 38400 57600 115200 Flow Control None gt 0 QQ 0 7 09 1 4 3 SIM Card Connector a Working Voltage 3V 1 8V b Slot Form Flip 1 4 4 Housing Dimensions length x width x height 110 X 85 X35 mm Please refer to the below illustration Installation fast fixing quick and convenient Anti shock minimum number of connectors excellent anti shock performance POWER MODULE SIM STATUS Product Dimensions InHand Networks EE OO ns neones 1 5 Product Models NETAS 5 35V DC RS 232DB9 connector gt A m on E UnDTUS31GS3T 2320 5 35V DC RS 232DB9 connector vu DTUSSKGSIT EP 5 35V DC RS 232Pin9 connector O sssvoc I eses terminal ee soc Remia ee ssvoe rss terminal RS 232 terminal RS 485 terminal RS 232 terminal RS 485 terminal RS 232 terminal RS 485 terminal TTL 5V Pin20 connector 5 26V DC RS 232 Pin20 connector 5 26V DC TTL 5V Pin20 connector 5 26V DC RS 232 Pin20 connector Connecting Devices Enabling Services 1 6 T
10. COM3 20124119 14 48 34 Detect device success Name GA Version AS rm BE ss Single click to input Configuration input box 3 2 The Configuration menu This part will introduce the configuration menu of INDTU300 3 2 1 Local COM1 Baud Rate 1200 2400 4800 9600 14400 19200 38400 57600 or 115200 bps Serial Data Bit 8 bit Serial Stop Bit 1 1 5 or 2 bit Serial Check Bit None Odd Even Serial Scan Interval 100 ms may just set to the default 10 Serial Timeout s may just set to the default 5 Frame Size Byte default is 1024 may set to any value between 1071024 3 2 2 Local COM2 Baud Rate 1200 2400 4800 9600 14400 19200 38400 57600 or 115200 bps Serial Data Bit 8 bit InHand Networks 2 wwwinhandnetworkscom Connecting Devices Enabling Services Serial Stop Bit 1 1 5 or 2 bit Serial Check Bit None Odd Even Serial Scan Interval 100 ms may just set to the default 10 Serial Timeout s may just set to the default 5 Frame Size Byte default is 1024 may set to any value between 1071024 3 2 3 Work Mode You can select the work mode of INDTU Link Mode Always Online Connect On Demand In Always Online mode INDTU300 keeps staying online and will auto reconnect whenever dropped off The Trigger by Call SMS COM data and Timed Activation functions are effective only in the Connect on Demand mode Trigger by Call open close
11. MN Connecting Devices Enabling Services InDTU300 series User s Manual This user s manual is only applicable to InDTU331 332 312 314 317 series products Q lt hana Beijing InHand Network Technology Co Ltd All rights reserved Republication without permission is prohibited Inland Networks E Connecting Devices Enabling Services InDTU300 User s Manual Copyright Notice Copyright O 2013 InHand Networks All rights reserved Reproduction without permission is prohibited Trademarks InHand is a registered trademark of InHand Networks Other registered marks cited in this manual represented their respective companies Disclaimer Information in this document is subject to change without notice and does not represent an obligation on the part of InHand Networks This user manual may include intentional technical or typographical errors Changes are periodically made to the manual to correct such errors and these changes are not informed in new editions Technical Support Contact Information InHand Networks China Tel 86 010 64391099 Fax 86 010 64399872 Email support Qinhandnetworks com Inland Networks contents INTRODUCTION TO INDTU300 SERIES cooccooccooccoccconcccccccococcons HLR EN Important Safety Information ooncccconcnncconcnnnnnnonononocnnnononononoss 1 2 PACKAGE CHECK Tusen rs 1 3 PRODUCT FEATURES cias in ur dTir ENEE ENCEN EN E 1 3 1 Hardwa
12. O ORG 004 Connecting Devices Enabling Services Physies COM Settings COM Select coma PC Time Baudrate 115200 v TT Auto DTU Time Advanced fe None 1 Current User 2012 5 9 11 00 50 1970 1 2 4 37 19 Admin A Restore to Detaut Write Conf File Read Conf File Save Conf File Load Conf File Read Log irmware Upgrade rowse betetoru downoad Data Center DTU No 0001 Center IP 203 86 63 238 3700 Domain Protocols TCP MAX Retries 5 Heartbeat Interval min 1 DNS IP 1 8 8 8 8 Receive18 byte datas AA 55 AA 55 03 00 09 81 2A 00 05 31 63 38 30 31 BF FD Baudrate 115200 DataBit 8 Parity N StopBit 1 5 Open Port COM4 Detect device success Data 55 AA 55 AA 07 00 00 70 06 Total frame length 9 TLVs length 0 Receive17 byte datas AA 55 AA 55 07 00 08 81 12 00 04 00 01 21 FF 3D 7D 2012 5 9 11 00 49 Got device time succes Beijing InHand Networks Technology NameDefalut Ver INDTU3XX_STD_V1 1 37 Jul 5 2011 19 13 44 7 Finished configuration click Write Conf File to save the configuration into InDTU300 InHand Networks El Configuation Local COM1 Local COM2 Work Mode tl GPRS settings Data Center a Center IP Multi Center Center Link Policy Others IEC 101 Settings Device Manager Admin Access ICMP Settings Custom UDP Connecting Devices Enabling Services med ORGIA 0
13. U300 will reboot InHand Networks Connecting Devices Enabling Services 3 3 5 Data Center Configure your data center IP address and the service port DTU Number DTU identification number only when using DC protocol it need to configure Center IP input the data center server IP address port number and DNS the IP address must be a fixed IP if you have DNS only just set it blank and turn to DNS Protocols TCP UDP client Modbus Bridge For Kingview SCADA you can also set DC UDP protocols The DC protocol is InHand private protocol it apply for marking different DTU which own a private IP address We can provide the SDK if you want to use it MAX Retries Maximum resend times when transmission failed O TCP protocol can auto resend Heartbeat Interval m The interval of heartbeat pack value range is 160 DNS IP 1 0 0 0 0 or the DNS address of your private address DNS IP 2 0 0 0 0 or the DNS address of your private address 3 3 6 Multi Center If enabled Multi Center pattern the field data can be sent to at most 5 data center User needs to fill in the IP address port number domain name for every center Leave it blank if Single Center pattern is selected Note If Multi Center not enabled please set the IP address and port number of all the non centers to zero 3 3 7 Center Link Policy MIN Re link Interval s the minimum interval to re link after connection fails in TCP MAX R
14. al the login box will pop up requiring the user to input username and password default adm 123456 Input username in the username dialog box click OK then input password in the password dialog box click OK The Login success box will pop up if the login succeeds otherwise the Login failure box will pop up When login succeeds the username will appear at Current User in the Physics COM Settings section If the user would not login at the beginning just click Cancel and login anytime after by clicking the login button After logged in the login button will change to logout user may also click the logout button anytime to cancel the login status Note Default username of administrator is adm password is 123456 inHand Networks Connecting Devices Enabling Services Default username of general user is guest password is 123456 Both username and password distinguish capital and small letters Now let s look at the main configuration interface In the Physics COM Settings section on the top user may select COM baud rate and serial port parameters The configuration tool will auto identify available COMs on current PC these COMs will then appear in the drop down list of COM Select the auto identification of available COMs will take a while after clicking on this item please wait for the COM list to appear please select the COM that connect wit
15. arameters of InDTU300 are correctly configured b Check if the SIM card is properly inserted in INDTU300 and make sure the SIM card is in service c If the remote data server is inside a LAN check if the firewall configuration of port mapping is correct gt InDTU300 is connected with server end data management program but cannot send data to the field control device a Please check the cable connection whether TXD RXD and GND are correct and whether the devices are using three line communication in RS 232 communication b Check if the communication parameters are correctly configured e g baud rate check bit etc gt Cannot upgrade InDTU300 through serial port b Please check if the serial cable is in good condition whether the PC s serial port works properly and if the ports are correctly set in INDTU300 s configuration Inland Networks MN Connecting Devices Enabling Services Support In case you have problems with the installation and use please address them to us by e mail support Qinhandnetworks com Copyright O 2013 InHand Networks All rights reserved Tel 86 010 64391099 Fax 86 10 64399872 Address Wangjing Science Park Road Lizezhonger Chaoyang District Beijing P R C 100102 Website http www inhandnetworks com Email info inhandnetworks com Subject to alterations without notice inHand Networks
16. com Product Configuration 3 1 The Configuration Interface After the installation is completed with INDTU300 powered off connect INDTU300 to a PC with a RS232 serial cable Then power on INDTU300 and start to configure it through the local serial port Run InDTU Confirguation exe and the configuration window will pop up as below INDTU Configuation 20120206 O de de it i E indie Configura 061 Connecting Devices Enabling Services Configuation Physies COM Settings ina COM Select COM3 PC Time 2012 11 19 14 34 41 Local COM2 H Work Mode Baudrate 115200 Auto DTU Time Sync Time H GPRS settings H Data Center Advanced Current User Logout Login H Multi Center GE ETER H Center Link Policy Restore to Default Read Conf File Save Conf File Load Conf File Read Log H Others Firmware Upgrade H EC 101 Settings J Device Manager Browse betestor H Admin Access H ICMP Settings Configuatior H Custom UDP gt gt gt gt Local COM Next Forward Baud Aate 9600 Serial Data Bit 8 bit Serial Stop Bit 1 bit Senal Check Bit None Serial Scan Intervalli 00ra 2 20121119 14 12 36 Program start with default baudrate 115200 2012 1119 14 12 36 Open Port COM3 Version ro __ At each launch the configuration program will auto run a hardware check If the result of the hardware check is norm
17. e Defalut Ver INDTU3XX STD V1 1 37 Jul 5 2011 19 13 44 pr 3 Before configure INDTU300 you d better read the conf file first Click Read Conf File button to get the configure file of InDTU300 InHand Networks Connecting Devices Enabling Services El Configuation E Local COM1 Frame Size Byte E Local COM2 Baud Rate E Frame Size Byte H Work Mode GPRS settings Auto Dialup Dialup Number PPP Heartbeat Interval s Redial Interval Connecting Devices Enabling Services ORGIA 001 Connecting Devices Enabling Services Physies COM Settings COM Select coma PC Time 2012 5 8 18 48 00 Baudrate 1 15200 vw Auto DTU Time 1970 1 1 12 22 40 Advanced fa None 1 v Current User Admin Restore to Defaut Write Conf File Read cont Fie Save Conf File Load Conf File f Read Log irmware Upgrade OOOO oe oeteetoru download Local COM2 Baud Rate 115200 Serial Data Bit 8 bit Serial Stop Bit 1 bit Serial Check Bit None Serial Scan Interval 1 O0ms 2 Serial Timeout 5 Receive10 byte datas AA 55 AA 55 05 00 01 01 23 C1 Login success Administrator Data 55 AA 55 AA 03 00 00 11 65 Total frame length 9 TLVs length 0 Receive18 byte datas AA 55 AA 55 03 00 09 81 2A 00 05 31 63 38 30 31 BF FD Baudrate 115200 DataBit 8 Parity N StopBit 1 5 Open Port COM4 Detect device success Beijing InHand Networks T
18. e link Interval s the maximum interval to re link after connection fails in TCP when you set tory here without other configuration INDTU can serve as a SMS modem Please see the detailed introduction in Section 5 2 InDTU300 as a SMS modem Roll Mode in Multi Center pattern set the multi center connection to roll mode or concurrency mode Input Y or y to set it to the roll mode any other input will set it to the concurrency mode TCP Server UDP Source Port interception port when working as TCP Server Fill in 0 to close the TCP Server function 3 3 8 Others MAX Login Times may just keep the default 10 Allow Telnet default is No Debug Yes or No If select Yes user will be able to see INDTU operation log through the serial tool This setting will take effect immediately after set InHand Networks Connecting Devices Enabling Services 3 3 9 IEC 101 Settings The InDTU300 support IEC101 protocol conversion It needs special firmware if you want to use this function You can contact InHand technical engineer to ask for the firmware 3 3 10 Device Manager Device Manager is Inhand remote device mange platform you can remote manage INDTU via the platform Product SN product serial number the identifying that Device Manager Identify InDTU Defined in factory and cannot be changed Work Mode SMS SMS IP and Disable Trusted Phone List the DM function of INDTU300 on
19. echnology Name Defalut Ver INDTU3XX STD V1 1 37 Jul 5 2011 19 13 44 Now you can configure what you want 4 Click Work Mode gt Link Mode and set as Always Online El Configuation H Local COM1 E Local COM2 Trigger by COM Data Timing Active Interval Timing Offline Devide Data Control Flow GPRS settings Data Center Multi Center Center Link Policy Others IEC 101 Settings Device Manager Admin Access ICMP Settings Custom UDP inori Configure Toni Connecting Devices Enabling Services Physies COM Settings COM Select coma y PC Time 2012 5 9 10 55 40 Sync Time Baudrate fi 15200 vw T Auto DTU Time 1970 1 2 4 31 49 Advanced fe None 1 v Current User Admin Logout Restore to Write Conf File Read Conf File Save Conf File Load Conf File Read Log Link Mode Always Online Y Link Mode Info 2012 5 9 10 55 28 Open Port COM4 2012 5 9 10 55 28 Detect device success Data 55 AA 55 AA 03 00 00 11 65 Total frame length 9 TLVs length 0 Receive18 byte datas AA 55 AA 55 03 00 09 81 2A 00 05 31 63 38 30 31 BF FD Baudrate 115200 DataBit 8 Parity N StopBit 1 5 38 Open Port COM4 8 Detect device success Beijing InHand Networks Technology Name Defalut InHand Networks 5 Click GPRS setting then input the right parameters you get from local mobile operator EJ InDTU Config Jatic 3s El Configuation E Local COM1
20. er is transparent UDP UDP Logout Frame logout frame when the connection pattern of data center is transparent UDP UDP Logout ACK Frame logout ACK frame when the connection pattern of data center is transparent UDP Inland Networks Note This setting is effective only when the connection pattern of data center is transparent UDP The login frame and login ACK frame must both be configured so are the other frames 3 3 Read and Write Configuration After completing the input of the configuration power on INDTU300 and make sure the hardware check result is normal then login with the administrator account click Write Conf to download the inputted configuration into INDTU300 The operation result whether writing is successful will appear in the bottom information window meanwhile the Write Conf Success dialog box will pop up if the writing is successful or the Write Conf False dialog box will pop up In the same way power on INDTU300 and login click Read Conf will read the configuration in INDTU300 into the configuration program If reading is successful the Read Conf Success dialog box will pop up otherwise the Read device config false box will pop up 3 4 Modify Configuration To modify the configuration of INDTU300 user may first read the previous configuration of INDTU300 into the configuration program modify the parameters whereas needed then write the updated configuration back in
21. gress 3 When the upgrading is completed a Serial Upgrade Success box will pop up as below click OK to quit then the Restart Device box will pop up select YES to restart the device and start to use updated firmware If the serial upgrade fails please check the hardware connection and port selection then run Check Hardware and Download Program again inrtand Networks Connecting Devices Enabling Services Note Device log is recommended to be closed during the serial upgrade If device log is open during the upgrade the large amount of serial data may impact resending of upgrade data and delay the upgrading progress 3 6 Read Device Log Connect INDTU300 to a PC with a RS232 serial cable TXD RXD or TXD2 RXD2 open the configuration tool and click Read Device Log the real time device log will display in the window Chapter 4 Application of Product For INDTU300 to work properly please make sure the following conditions are met 1 Power supply is normal 2 INDTU300 is inserted with a valid SIM UIM card that supports data service 3 INDTU300 is placed where it can receive GPRS CDMA signal 4 INDTU300 is correctly configured e g IP address and port number of the data center that INDTU300 should call on communication protocol etc Work Principle of INDTU300 Power on INDTU300 and dial in the GSM CDMA network After INDTU300 obtained an IP address register to the data center
22. h InDTU300 2 After the right COM is selected user may click Write Conf File or Read Conf File to write or read the configuration of InDTU300 Or click Save Conf File to export the configuration as a text file click Load Conf File may import the saved configuration file back into the configuration tool 3 The bottom information window displays current operation and whether the operation is successful 4 The Sync Time button will set system time of the device to the current time of the PC after clicking Sync Time the configuration tool will auto read the device time and display it at DTU time in the Physics COM Settings section 5 User may upgrade the firmware through a serial port by the Firmware Upgrade option Detailed upgrade steps are introduced in Section 3 5 Firmware Upgrade 6 When reading and writing of the configuration is successful the software version of InDTU300 will display at Version on the bottom bar 7 Click an item in the menu tree on the left the information window on the right will display the configurations under this menu item Click on an item in the 1st level menu all the configurations under this item will display in the information window user may review the configurations by rolling through the drop down list Click on one of item in the menu tree will open the next level menu Click on the 3 rd level menu it will enter the configuration input wi
23. ht COM port and enable Auto to let software auto detect InDTU300 or click the Detect DTU to check if connection is correctly El Configuation l Local COM1 Serial Stop Bit Serial Check Bit Serial Scan Interval 100n Serial Timeout Serial Stop Bit Serial Check Bit Serial Scan Interval 100n Serial Timeout i Frame Size Byte H Work Mode E GPRS settings PPP Heartbeat Interval s Redial Interval inor ORGIA 1001 Connecting Devices Enabling Services Physies COM Settings COM Select COM4 y Baudrate 115200 y Auto Advanced fa None 1 Restore to Defaut Write Conf File irmware Upgrade 2012 5 8 18 28 16 1970 1 1 12 04 39 PC Time DTU Time Sync Time Logo Login ut Read Conf File Save Conf File Load Conf File Read Log Current User NA detect oru Local COM2 Baud Rate 115200 Serial Data Bit 8 bit Serial Stop Bit 1 bit Serial Check Bit None Serial Scan Interval 100ms 2 Serial Timeout 5 Receive17 byte datas AA 55 AA 55 07 00 08 81 12 00 04 00 00 39 57 F255 Got device time succes Data 55 AA 55 AA 03 00 00 11 65 Total frame length 9 TLVs length 0 Receive 18 byte datas AA 55 AA 55 03 00 09 81 2A 00 05 30 63 38 30 31 FB F6 Baudrate 115200 DataBit 8 Parity N StopBit 1 5 Open Port COM4 28 14 Detect device success Ver INDTU3XX STD V1 1 37 Jul 5 2011 19 13 44 If you see the following
24. ly accepts SMS sent from trusted phone numbers If the list is empty it will accept SMS sent from any number Device ID identification of the Device Manager Defined in factory and cannot be changed Platform Address IP address and port number of Device Manager Heartbeat Interval s heartbeat interval with Device Manager range is 307600 3 3 11 Admin Access Administrator Account to set username of the administrator account Administrator Password to set password of the administrator account User Account to set username of the general user account User Password to set password of the general user account 3 3 12 ICMP Settings Detection Host detect whether the PPP connection is normal Input IP address which always on line MAX Package Lost redial if fail to receive data package after sending ICMP for the maximum times Idle Time s send ICMP detection package if not receiving network data for a period over this time range is 3073600 3 3 13 Custom UDP UDP Type ASCII or HEX ASCII type uses ASCII character HEX type uses HEX character UDP Login Frame login frame when the connection pattern of data center is transparent UDP UDP Login ACK Frame login ACK frame when the connection pattern of data center is transparent UDP UDP Heartbeat Frame heartbeat frame when the connection pattern of data center is transparent UDP UDP Heartbeat ACK Frame heartbeat ACK frame when the connection pattern of data cent
25. mechanism preventing Soft Watch dog system halt E Default administrator Support 2 user grades administrator username adm Password 123456 General username Authentication by and general user User Grades Username and password are required to use local management functions guest InHand Networks P wwwinhandnetworksicom Connecting Devices Enabling Services Before the power outage the super Capacitance needs to be supplied with During a power outage the internal power for no less Real time Clock super Capacitance will supply power to than 2 hours RTC to keep the system time running otherwise the system will restore to the default time 1970 1 1 0 0 0 To implement Write in default settings while erasing through the Restore Default all current settings configuration program PPP Protocol Point to Point Dialing Protocol Support CHAP Certification Certification method PAP Certification Certification method Maintain connection to the operator s network preventing forced hibernation PPP Layer Heartbeat Di i Network May detect stability of the dial up connection l Maintain connection to the operator s ICMP Detection network Functions Detect connection with application TCP Layer Heartbeat server on the TCP layer Application Layer Detect connection with application Heartbeat server on the application layer Upgrade Upgrade through local
26. ndow Please refer to the picture below 8 write Conf and Download Firmware can only be accessed by the administrator general user can t change the configuration or firmware of InDTU300 Inland Networks Connecting Devices Enabling Services Connecting Devices Enabling Services p de InDTU Configuation 20120206 ecting Devices Enabling Services Double click to open or close next level menu i Local COM1 AD J Local COM2 PC Time 2012 11 19 14 48 42 HEN i Work Mode Baudrate 3600 Auto DTU Time 1970 11 11 15 12 a A Advanced 3 None 1 Current User Admin Logout Center of Restore to Defaut Write Conf File Rea Fi Save Conf File Load Conf File Read Log pf i Firmware Upgrade e E venns Heartbeat Intervakmin i DNS IP 1 i DNS IP2 ee configurations Center Link Policy H Others H IEC 101 Settings EEE ger 2012 11 19 14 48 30 Receive10 byte datas AA 55 AA 55 05 00 01 01 23 C1 gt Admin Access 2012 1119 14 48 30 Login success Administrator H ICMP Settings 2012 11 19 14 48 33 Data 55 AA 55 AA 03 00 00 11 65 H Custom UDP 20121149 14 48 33 Total frame length 9 TLWS length 0 i 2012 11 19 14 48 33 Receive18 byte datas AA 55 AA 55 03 00 09 81 2A 00 05 31 36 38 30 30 77 57 2012 11 19 14 48 33 Baudrate 9600 2012 11 19 14 48 33 DataBit 8 2012 11 19 14 48 33 Parity N 2012 11 19 14 43 34 StopBit 1 2012 1149 14 48 34 Open Port
27. on cost for customers InDTU300 is well proven product approved by high end customers including Siemens Schneider Electric China State Grid and etc And it is compliant with smart grid industrial DL T 721 2000 Standard of tele control in Power Grid automation system InHand Networks EE Connecting Devices Enabling Services Important Safety Information This product is not intended for use in the following circumstances e Area s where radio transmission equipment such as cell phone are not permitted e Hospitals health care facilities and area s where cell phones are restricted by law e Gas stations fuel storage and places where chemical are stored e Chemical plants or places with potential explosion hazard e Any metal surface that may weaken the radio signal level RF safety distance For GPRS router the compliance boundary distance 1s r 0 26m for GSM 900MHz and r 0 13m for DCS 1800 M Hz Warning This is a class product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures WEEE Notice The Directive on Waste Electrical and Electronic Equipment WEEE which entered into force as European law on 13th February 2003 resulted in a major change in the treatment of electrical equipment at end of life The purpose of this Directive is as a first priority the prevention of WEEE and in addition to promote the reuse recycling and othe
28. orkscom Connecting Devices Enabling Services Category Function Description Notes Support Support GPRS CDMA network GPRS CDMA Serial port Configure via external serial port Configuration Status Indication LED indication of operation status Flexible Installation Support wall or desk installation VPDN connection Support Virtual Private Data Network Transparent Transparent and two way transmission Transmission of application data DC private protocol MODBUS bridge Protocol Conversion l Self defined UDP protocol Always Online Keep connected to the application Mode server Connect to the application server when Connect on Demand Mode _ triggered by configured activation method In Connect on Demand Mode trigger Trigger by COM Data hibernating INDTU300 to connect to the network by sending local COM data In Connect on Demand Mode trigger l i Trigger by Call hibernating INDTU300 to connect to the Basic Functions network by a phone call In Connect on Demand Mode trigger Trigger by SMS hibernating INDTU300 to connect to the network by DM Timed Online Set time to auto trigger INDTU300 to Export device log from the serial port Device Log for the technical staff to check running status of INDTU Multiple Serial port Communication Supported baud rate 12007115200bps Rate a Ports differ by RS232 485 Support RS232 485 communication product model Watch dog
29. r forms of recovery of such wastes so as to reduce disposal The WEEE logo shown at the left on the product or on its box indicates that this product must not be disposed of or dumped with your other household waste You are liable to dispose of all your electronic or electrical waste equipment by relocating over to the specified collection point for recycling of such hazardous waste Isolated collection and proper recovery of your electronic and electrical waste equipment at the time of disposal will allow us to help conserving natural resources Moreover proper recycling of the electronic and electrical waste equipment will ensure safety of human health and environment For more information about electronic and electrical waste equipment disposal recovery and collection points please contact your local city centre household waste disposal service shop from where you purchased the equipment or manufacturer of the equipment InHand Networks 1 2 Package Checklist We put each InDTU300 in a box with standard accessories Additionally there re optional accessories can be ordered When you receive our package please check carefully if there re items missing or appearing to be damaged please contact with InHand Networks sales representative Items in package include Standard Accessories Accessories Description Qualification Certificate and Guarantee i Card Optional Accessories Accessories Description
30. re Features rrsrarnvnnnnvnnnnvnnvnvnnnnvnvenenvenenvnnenernnnennenenee 1 3 2 So WOTG FOQUUIECS ua dd 1 4 TECHNICAL PARAMETERS sacomananatatoens lt aavacsvannhiuusceaaneitedateurncadtaciarnatacens 1 4 1 Standard PALAMECtelS cccccsccececcsceecsceccscsscscesescescscsseecscess TENNE ee Ie en A 1 4 3 SIM Card Connector vasveeewwsaceranustiaxaviesiaxewxstinoonesinevieasteusesewsoa TAA HOUSING EE EE EE II aL sr ODUCT INI Jr LTR PRODUCT INSTALLATION siria aia 2 1 HARDWARE INSTALLATION sscssiavsionansscatensasnecaasddealonsdevsdeaseuecdsatonismeciees 2 1 1 Fixing and Power Connection rrrnnrrrnnnrrnnnrrnnerrrnerrrnanvnnnnsenn GER ARS e e O wncstau acoeioeme sumseeseands 2 1 3 Check Network CONNecti0N ocooccoccccoccncnonnonccnnononcnncanonononns 2 2 SOFTWARE INSTALLATION s rroreervnrnnnvrrnnvnnnnrrnnrnnnsrrnnnnnnsssnnsnnnsssnnsnn PRODUCT CONFIGURATION sis scsnusciccessnsccavontescsnvensvesnvaeevessiensenssuntsounes 3 1 THE CONFIGURATION INTERFACE cccssssecccceeeseeeeceaeeeeeeesaeneeeeees 3 2 THE CONFIGURATION MENU cccccsssecccceesseccceseusecccesaeseeceesaueseeees TN STONE Inland Networks Connecting Devices Enabling Services E e E ee reer rer ee et ee ee eee ee er ere 21 NNN anillo E 21 E A EE o E EEE 22 ES AA O sagen eee o e A 22 NNN 22 E O o A E E e A A III 22 Se PP e 23 33 10 Device Manager A ata 23 co es a ms AOA A PP E er nee
31. re rer ee ee ere ee er ere 23 FAAL A e iM OE EE NE A 23 En CUSTOM UD sar EN NE oa 23 3 READ AND WRITE CONFIG URATI N datada tri 24 34 MODIFY CONFIGURATION sra aa 24 RON 24 RED DEVICE LOC vn 25 CHAPTERA APPLICATION OF PRODUCT Luske 25 IDE MODE INTRODUCTION NG 25 AAA e o o E OE O O A 25 NNN 25 NNN 26 4 3 CHECK SYSTEM AND CONNECTION STATUS evennnnvrnnnrnnnnnnnnrnnnennnnnnnnrnnnennnnnnnnnnnnennnnnnnnnnnnnnnnennnnnnnnnnnnennnnnnnnennnennnsnnnnenene 27 CHAPTER 5 CONFIGURATION GUIDE nsinsinnicarinicas acceda 28 FV NTP 28 SMV NNN 32 FACO recat cman cesa aunts o o 5 E SEN 34 A E O E E EEE 35 inHand Networks Connecting Devices Enabling Services MN Connecting Devices Enabling Services Introduction to INDTU300 Series 1 1 Overview The InDTU300 Series of industrial quad band GSM GPRS Digital Terminal Units DTU are designed to transmit serial data over GSM GPRS mobile networks The modems are light weighted compact designed modems combined with rich features of high performance high security and low power consumption And they bases on professional industrial chip design capable to work robustly in harsh outdoor circumstances for example wide operation temperature ranging from 25 C to 70 C 13 158F wide range power input from SV to 35V and strict EMC conditions The modems can support several management tools include handheld configuration tool Device Manager which significantly reduce the maintenance and installati
32. to INDTU300 the corresponding settings will then be changed User may also export and save the configuration file of INDTU300 after inputting When modification is needed import the saved file and modify whereas necessary then write the updated configuration back into INDTU300 Each INDTU is loaded with default configuration when leaving the factory User need to read the loaded configuration and make modifications whereas necessary e g the IP address and port number of center end have to be input by the user so INDTU300 could connect to the user s central control system 3 5 Firmware Upgrade 1 Connect INDTU300 to a PC with a RS232 serial line With INDTU300 powered off copy the upgrade code file that InHand provides under a non Chinese directory on PC then click Read File on the configuration interface to read the path of the code file into the input box of Send File Power on INDTU300 and click Check Hardware if the hardware status is normal the Hardware Check Success box will pop up INDTU300 is now ready for serial upgrade If the Hardware Check Failure box pops up please check whether the serial cable is properly connected and if serial parameters are correctly configured then run Check Hardware again 2 After hardware check is successful login with the administrator account and click Download Program to start to upgrade the program The lower information window will display the upgrading pro
33. to connect up with the center The cache of INDTU300 s serial port is 4K if data sent during this period is smaller than 4K these data will be sent after INDTU300 connects with the center if data sent during this period is more than 4K the exceeding part will be abandoned InHand Networks Connecting Devices Enabling Services KE Connecting Devices Enabling Services 4 3 Check System and Connection status User may observe the system and connection status of INDTU300 from the LED indications on the front panel LED Indications POWER AY CO 1104 DS h7 STATUS Description On Xx Fast Flash Alternatively Start Module on x or Slow Flash EE Fast Flash Slow Flash PPP Dialup to Internet On gt i X Slow Flash Off Wait for dialup trigger for connection on JJ a X Slow Flash Alternatively Successful PPP Dialup to Internet wait for JJ med On means to be constantly on i e keep on without flashing for at least 3 seconds Note Off means to be constantly off i e keep off without flashing for at least 3 seconds Slow flash means to flash at a rate around 1Hz Quick flash means to flash at a rate around 5Hz InHand Networks Connecting Devices Enabling Services Chapter 5 Configuration guide 5 1 InDTU300 as a TCP client In this chapter we will briefly introduce how to configure when InDTU300 as a TCP client 1 After correctly link InDTU300 to PC open the configure software select the rig
34. ver drops INDTU300 transfers the serial data it receives to center end when there is no serial data coming in INDTU300 will send heartbeat pack to center end according to configured time interval to make sure the link is connected 4 2 2 Connect on Demand To use the Connect On Demand mode set the parameters of InDTU300 as below Link Mode Connect on Demand Trigger by Call Open or Close Trigger by COM Data Open or Close Timed Active Interval m 0 1440 0 means to trigger at once after it drops offline i e do not enter hibernation mode Timed Offline m 1760 Divide Data Control Flow Yes Note In this link mode please turn on at least 1 of the 3 trigger mechanisms In this link mode user may set when InDTU300 should connect to the network and when to disconnect For example set Timed Offline m to 2 Timed Active Interval m to 720 Trigger by Call to Open and Trigger by COM Data to Close the InDTU300 will get offline and enter standby mode when there s no data transmission for over 2 minutes then user can trigger it to get online by a phone call or it will auto reconnect after 720 minutes So user may choose to set to trigger INDTU300 to get online by a phone call or after a given interval or when a lower end device sends data any data to its serial port Note When to be triggered by COM data after the triggering data pack is sent INDTU300 will need a while within 20seconds
35. will become a SMS modem InHand Networks Connecting Devices Enabling Services E Configuation H Local COM1 Local COM2 Work Mode GPRS settings Center Multi Center Center Link Policy gt MAX Login Times Allow Telnet IEC 101 Settings Device Manager Admin Access ICMP Settings Custom UDP InHand Networks Physies COM Settings COM Select PC Time Baudrate 115200 7 Auto DTU Time Advanced 8 None 1 Current User Restore to Defaut Firmware Upgrade Write Conf File Read Conf File aa trowse EE inori configure 000 Connecting Devices Enabling Services 2012 11 20 12 20 45 h Sync Time Logout Login Save Conf File Load Conf File Read Log Download Ce r Jet Fora Max Re link Interval Info Range 157600 Note Default 15 Please smaller than Min Re link Intervallnf o 2012 11 20 12 14 58 Program start with default baudrate 115200 Version 4h Connecting Devices Enabling Services FAQ gt Power LED is not on a Please check if power supply is normal and whether the electrodes are correctly connected gt Cannot configure INDTU300 a Please check if the serial cable is in good condition whether the PC s serial port works properly and if the ports are correctly set in INDTU300 s configuration gt InDTU300 is powered on but cannot connect with the remote data server a Check if the p
36. ypical Application InDTU300 series uses GPRS CDMA network as bearer network to carry out remote data collection and transmission and implement remote monitoring in industry complete solution will enable the customer to gain utmost production and operation efficiency while with minimal investment Below is an illustration of the typical network pattern of InDTU300 Database System GPRS CDMA RS232 485 TE d GF DN sii a SIV SS ig Public IP ISP Station rior RS232 485 Data Analysis System Typical application topology InHand Networks gt wwwinhandnetworkscom Connecting Devices Enabling Services Product Installation The installation of the product includes Hardware installation and Software installation optional We give example by INDTU332 2 1 Hardware Installation Note Please do not install this product when power supply is connected 2 1 1 Fixing and Power Connection INDTU332 is hold in a plastic housing On the bottom of the housing there are screw holes for fixing the INDTU332 1 Connectors on the housing are listed in the following table GND TXD 485 RXD 485 RXD2 TXD2 GND V Ve Connectors Description Notes RXD2 Configure serial receiving InHand Networks Connecting Devices Enabling Services support 232 only TXD2 Configure serial sending support 232 only CT NID Digital ground Provide serial port ground connection ve CO
Download Pdf Manuals
Related Search
Related Contents
IT - Manuale di istruzioni The CAS server – User Manual White-Westinghouse 318200659 User's Manual Bedienungsanleitung Puertas de alto rendimiento w w w .h o rm a n n Archivobjekt öffnen - Katalog der Deutschen Nationalbibliothek 250KB Digital Receiver For SALSA Piezas - Graco Inc. Retrovirus Titer Set(for Real Time PCR) Copyright © All rights reserved.