Home

GSM-4000

image

Contents

1. use your own password to the SIM number on Pump GSM unit This will switch Off the pump 3 Connect the lower level switch to input 2 of the tank unit 4 Program the tank GSM unit so that when input 2 is activated it sends SMS 1234CC 1234 is the default password used as an example Please use your own password to the SIM number on Pump GSM unit This will switch ON the pump Notes Make sure that in the Tank unit the first SMS alert number is that of the SIM card in the Pump GSM Unit Application 2 Below is an example of a semi automatic Tank control unit The GSM 4000 can be configured in 2 ways 1 Switch On the pump for a certain period of time The user should know how long it will take to fill the tank 2 Switch pump On and Off with SMS messages after receiving the status of the tank In the Ist configuration the pump is connected to relay of the GSM 4000 Input 1 is connected to the low level switch on the tank When the tank is empty relay 1 is activated for a certain period of time thus switching the pump On The user can also have input 2 connected to a high level switch which will send the user an SMS message when the tank is full In the 2nd configuration the pump is connected to relay 2 of the GSM 4000 Input 1 is connected to the low level switch on the tank When the tank is empty the user gets an SMS message The user then sends a message to switch On relay 2 which switches the pump When the tank is full t
2. Activates by SMS message Rated at 3A at 240VAC Page 4 www elsema com GSM Receiver with relay output GSM 4000 SMS Commands List Arm the GSM 4000 Disarm the GSM 4000 Switch relay 2 ON Switch relay 2 OFF GSM 4000 status Please note that all SMS commands should be in upper case and is preceded by a password Below is an example password is 1234 1234AA Correct 1234aa Incorrect The user can arm disarm switch relay 2 On and Off and check the status of the unit by sending SMS messages e ARM the Unit rmed A e DISARM the Unit Se ae wdBB Disarmed e Switch relay 2 ON en eee wdCC Output Relay Closed e Switch relay 2 Off a a aaa wdDD Output Relay Opened e GSM 4000 Status Armed or Disarmed AC Power Ok or AC Power is failed GSM Value is xx number depending on the GSM signal level Output relay is Opened or Output relay is Closed Page 5 www elsema com ELSEMA GSM Receiver with relay output GSM 4000 Computer interface software 41 GSM SMS Controller Alarm Confi i x COM Settings ee 5 x Se Attention Please switch on the unit after you press Save Settings button Com Porn Emm gt Save Settings Read Settings Save Profile Load Profile Stop _ EEE F v J L Alarm Dial Tel Numbers Input Type When Input Activated SMS Content When Input Recovered SMS Content Alarm Link Output R
3. ELSEMA GSM Receiver with relay output GSM 4000 GSM 4000 GSM SMS controller for automatic switching of devices Features Switches relay with SMS messages Sends SMS message when inputs are activated Supports NO or NC inputs Easily programmed with user friendly computer software Operates from anywhere if GSM network is available Unlimited range Ignores unauthorised numbers 4 digital inputs for sensors or switches Built in rechargeable back up battery Lasts for up to 24hours Secure Password protected 12 Volts DC power pack included Application Automatic switching pumps irrigation systems Security alarm fire alarm temperature monitoring Endless applications Description The GSM 4000 has 4 inputs which can be set as NO NC or Disabled The GSM 4000 can be programmed to send an SMS message when any of the inputs are triggered or recovered There are 2 relay outputs Relay 1 can be programmed to switch On when any of the inputs are triggered and relay 2 can be switched On by SMS message The GSM 4000 also has a microphone mic and a speaker connection It can be programmed so that when an input is triggered the GSM 4000 makes a call to the programmed numbers and create a 2 way voice communication All configurations are done through a user friendly computer software The GSM 4000 connects to the computer through a standard USB connection The GSM 4000 works on GSM networ
4. MS to SMS No 1 to alert user Password 1234 4 digits only The password to access the GSM Controller when use SMS Commands to control it Serial Port Status nmunicatic Inforgggtior Alarm Dial Tel Numbers A call will be made to these numbers one after the other if any of the inputs are triggered Calls will be made after SMS is sent to SMS Alert Numbers Select Input Type Normally Open NO Normally Closed NC or Disable All unused inputs should be set as disabled When Input Activated Type the SMS message which will be sent to SMS alert numbers when SMS Content corresponding inputs are triggered max 34 characters When Input Recovered Type the SMS message which will be sent to SMS alert numbers when SMS Content corresponding inputs are recovered Tick don t care check box if you do not want to use this feature max 34 characters The unit will not make a call when the input are recovered Alarm Link Output Relay When enabled relay 1 will switch On when the inputs are triggered Sound Alarm When enabled the siren output will be activated for 60sec when any inputs are triggered GSM Jammer If there is no GSM signal present for 90 sec relay 1 will switch on for 4minutes and the siren output for 60sec It s not recommended to enable this feature ARM The GSM 4000 will automatically enter into armed mode on power up If unchecked it will not arm on power up Report Time This option will send SMS message to the Ist SMS aler
5. elay TEL No 1 Input 1 Disable gt Wired input 1 alarm Don tCare Wired input 1 Recovered Enable Disable TELNo 2 Input 2 Disable Wired input 2 alarm v Dont Care Wired input 2 Recovered Enable Disable TEL No 3 Disable Wired input 3 alarm v DontCare Wired input 3 Recovered M Enable Disable Input 3 TEL No 4 Input 4 Disable r Wired input 4 alarm ADon tCare Wired input 4 Recovered Enable Disable TEL No 5 Input5 Disable gt Wired input 5 alarm ViDon tCare Wired input5 Recovered Enable Disable SMS Alert Numbers SMS No 1 Input 6 Wired input 6 alarm ViDon tCare Wired input 6 Recovered M Enable Disable eee Di 1 Wired input alarm v Don t Care Wired input Recovered Enable Disable SMS No 2 Bree SMS No 3 Input 8 Disable gt Wired input 6 alarm ViDon tCare Wired input 8 Recovered _ Enable Disable Other Settings _ Sound Alarm vhen alarm happened the siren will make sounds for 1 minutes _ GSM Jammer Aler When no GSM Signal for 30Seconds will alarm Not Recommend _ ARM Vhen Switch On the GSM Controller will enter into Armed Mode Report Time 0 0 240Hours Automatically Send SMS to SMS No 1 to alert the GSM Controller Condition Alarm Delay Time 0 1 90Seconds The delay time to carry out the alarm Relay working Time 0 0 120Minutes The working time of the Alarm link output relay when alarm happened Powerdown Alert BEM1S G When AC Power Goes off how long to send S
6. he high level switch connected to input 2 will send an SMS message to the user telling the tank is full The user then sends another message to switch Off relay 2 which switches the pump Off 6 4 GSM 4000 ELSEMA NO of Relay 1 or Relay 2 Active Motor C of Relay 1 or Relay 2 Neutral Supply Input 2 Page 8 www elsema com ELSEMA GSM Receiver with relay output GSM 4000 Application and 2 are just illustrations of how the GSM 4000 can be used The GSM 4000 can be used in many other ways depending on your imagination or your applications Optional Optional microphone and Speakers can be connected to the GSM 4000 to create a 2 way communication under the following 2 conditions 1 When any of the inputs are triggered The GSM 4000 makes a call to the user 2 When an authorised user makes a call to the GSM 4000 When installing siren and microphone please make sure that the siren is as far away as possible from the microphone Manufactured by Elsema Pty Ltd 31 Tarlington Place Smithfield NSW 2164 Ph 02 9609 4668 Fax 02 9725 2663 Website http www elsema com Page 9 www elsema com
7. hone and speaker O O Sst an MIC SPK MIC 3 5mm socket for external microphone for 2 way communication optional SPK 3 5mm socket for external speaker for 2 way communication optional Connect the GSM antenna provided Use a high gain antenna if signal is poor USB Connect to your COMPUTER for setup using the GSM 4000 software Inputs and Outputs 42VDC Input Gnd Input Input Grd Input 12VDC C 4 C NO 12VDC Siren Supply Output 3 4 Relay1 Relay 2 Connect the 12VDC power pack supplied with the GSM 4000 Supply If siren is used please make sure that the power supply is big enough to supply the GSM unit and the siren Siren or strobe light output This outputs will activate siren or Siren strobe light when alarm is activated optional 12VDC 12VDC to supply sensors aoe Digital input 1 Connect sensors push buttons switches etc If it is not used please P set it as Disabled in the software Gnd Ground Input 2 Digital input 1 Connect sensors push buttons switches etc If it is not used please set it as Disabled in the software Digital input 1 Connect sensors push buttons switches etc If it is not used please Input 3 Set it as Disabled in the software Tatra Digital input 1 Connect sensors push buttons switches etc If it is not used please Er Set it as Disabled in the software 12VDC 12VDC to supply sensors Relay 1 Activates when any of the inputs are triggered Rated at 3A at 240VAC Relay 2
8. ith relay output GSM 4000 Setup Instructions 1 The GSM 4000 is easily setup using the computer software provided 2 For added security there is and On Off switch and a setup and normal operation switch When the unit is connected to the computer please make sure that the switch is in setup position 3 Make sure that after you have finished setting up the unit slide the switch to normal operation mode 4 The default password is 1234 It can be easily changed by the computer software 5 A two way voice communication is possible when external mic and speaker is connected to the unit A two way voice communication established when a An authorised user makes a call to the unit or b The unit is programmed to dial a number when an input is triggered 6 The backup battery inside the GSM 4000 does not control the output relays If the supply to the unit is switched Off the 2 output relays will switch Off as well 7 The GSM 4000 can only handle one alarm event at a time Connections and Display LED indicators 6 g amp GSM Relay Armed Alarm On On Network indicator GSM Flashing fast Searching for a network Flashing slowly Successfully connected to the network Relay On Indicates switching of relay 1 or relay 2 On Unit is armed Off Unit is disarmed Alarm is activated Page 3 www elsema com ELSEMA GSM Receiver with relay output GSM 4000 Antenna USB and optional microp
9. k therefore the receiver can be activated from anywhere in the country where GSM network is available For example you can open your gate or switch on your kitchen lights in Sydney from Melbourne by sending a simple SMS message The GSM unit can be armed and disarmed by simple SMS message 12 Volts DC Power Pack Included Page 1 www elsema com ELSEMA GSM Receiver with relay output GSM 4000 Technical Data Power Source 12 Volts DC GSM Frequency 900 1 800MHz Output Common C and Normally Open NO relay outputs rated at 3A 240V AC Shipping Weight 690 grams 155 x 95 x 28mm Safety Instruction Safe startup Do not use the GSM 4000 in places where GSM equipment is prohibited or might bring disturbance or danger Interference gt Wireless equipment might interfere GSM network signals of the GSM 4000 and influence its performance Avoid using at Gas Stations Do not use GSM 4000 at a gas station Power off the unit when near fuels or chemicals Avoid using near blasting areas DANGER BLASTING AREA J Please follow relevant restrictive regulations Avoid using the device in blasting places Reasonable Use Please install the product at a suitable place as described in this manual Avoid signal shielding by covering the mainframe Maintenance All wiring and maintenance should be carried out only by qualified maintenance personnel Page 2 www elsema com ELSEMA GSM Receiver w
10. l the required parameters according to your application Click on the Save Settings button and after 2 secs switch on the GSM 4000 The On Off switch is beside the SIM card holder If the setup is successful a pop up window will open If the setup is not successful you can try changing the COM ports Correct COM port is indicated by the a green LED for communications at the bottom of the COMPUTER interface window a oe 8 Switch Off the unit and then disconnect the USB cable Follow step 9 if COM port 1 5 don t work 9 a Go to the device manage in your controls panel of your computer b Click on the Ports COM amp LPT c You should see the USB driver here Make note the COM port number The COM port number should be from 1 5 If it is not go to properties and then change it If you have to change the COM port setting you will need to restart you computer Application 1 Below is an example of a fully automatic tank pump control system using two GSM 4000 The pump and the tank can be any distance apart Tank Unit Pump Unit 47 GEM a D 2222 A di peeti D 2222 e ELSEMA ELSEMA Motor Active Supply Neutral Page 7 www elsema com ELSEMA GSM Receiver with relay output GSM 4000 Setting up the tank and the Pump unit 1 Connect upper level switch to input of the Tank unit 2 Program the tank GSM unit so that when input 1 is activated it sends SMS 1234DD 1234 is the default password Please
11. t number every set period on the GSM 4000 status Having 0 in this field will disable this feature Alarm Delay Time Sets the delay time from input trigger to alarm switching Relay working time Sets the off delay of relay 1 when any of the inputs are triggered Power Down Alert Sets the time after which the unit will send SMS message when AC power switches OFF Password to access the GSM 4000 when using SMS commands Default is 1234 Page 6 www elsema com ELSEMA GSM Receiver with relay output GSM 4000 TIn an event where the inputs are activated and held active the GSM 4000 will only send one SMS message It will send another message if the same input is recovered and triggered again This makes it ideal to be used for monitoring temperature moisture humidity etc Computer Interface Setup Please follow the following instructions carefully Make sure that the setup switch is on setup and not normal operation and the power switch is in Off position 1 Connect the GSM 4000 to your computer Do not switch the GSM 4000 ON yet 2 Install the USB driver provided from the Flash on your computer CP210x VCPInstaller exe The driver can also be downloaded from Silicon labs website CP210x The default COM selected should be COM3 If it does not work please see step 9 Insert the SIM card into the SIM holder at the bottom side of the unit Now run the computer Interface software It does not need installation Setup al

Download Pdf Manuals

image

Related Search

GSM 4000 gsm 4000 gsm 4000 manual rescue gsm 4000 lte rescue gsm 4000-lte videx 4000 series gsm somag gsm 4000

Related Contents

pioneer - Pellegrino  Tiller Mode d`emploi  Operating instructions Electronic pressure sensor PM205x  Eton ARCPT300W User's Manual  Toshiba PQQ14U004001 Personal Computer User Manual  iWalk2.0 User Manual    Manual Tipping Bucket Flow Gauge Model 6506  MANUEL D`INSTALLATION ET D`UTILISATION  CM901 - Guía Del Usuario  

Copyright © All rights reserved.
Failed to retrieve file