Home
Fitting Instructions
Contents
1. 44 0 113 276 7244 CE and e approved L209 Distributed by Ring Automotive Gelderd Road Leeds LS12 6NB Tel 44 0 113 276 7676 Fax 44 0 113 231 0266 Email autosales ring Itd uk 4 PowerSource Mains powered equipment from a 12v source User Manual 12v DC to 230 24HOvu AC Power Source 500 Watts Model RINVSOO Powering Then Ulitimeta im Portabla Introduction The Ring PowerSource is an electronic device that converts a low voltage 12v DC current from a battery or other source and provides 230 240v AC current Special attention should be made to CAUTION statements in this users manual CAUTION statements identify conditions or practices that could result in damage to your PowerSource or to equipment that you are using with it CAUTION When connecting the PowerSource directly to a battery or other power supply ensure that you observe correct polarity Ensure the red positive lead is clamped to the positive battery terminal and the black negative lead is attached to the negative battery terminal Do not exceed the maximum input voltage 15v DC Do not remove the protective cover under any circumstances only by a qualified electrician Improper use of the PowerSource can cause damage to property and possible harm to the user Power Supply The battery or power supply must provide between 10 5 and 14 5v DC a car battery will usually pro vide this and must be able to provide sufficient
2. below Over voltage protection The PowerSource will automatically shutdown if the input voltage exceeds 15v DC Reverse polarity protection Reverse polarity incorrect battery connection may result in the blow ing of the internal blade fuses If this occurs immediately disconnect the battery The internal blade fuses will need to be checked by a qualified electrician if the PowerSource does not continue to work Overload protection The PowerSource will automatically shut down if the continuous power draw exceeds its maximum rating of the PowerSource Temperature protection If the temperature of the internal heat sink reaches gt 65 C the PowerSource will shut down automatically Allow the PowerSource to cool before using again
3. cables supplied Ensure the load requirements are within the parameters of the PowerSource output plug your appliance into the socket of the PowerSource Ensure the PowerSource is switched off prior to plugging any accessories and connecting to battery or power supply CAUTION Some rechargeable products have a charger that is designed to be plugged directly into mains 240v sockets These can damage the PowerSource When first using a rechargeable product monitor its temperature for 10 minutes to ensure overheating does not occur Fuse replacement RINV500 35amp x2 Internal blade fuses Please consult a qualified electrician to replace any fuses Positioning of PowerSource The following points should be noted The PowerSource is not waterproof The PowerSource should be placed on a ventilated flat surface Do not put the PowerSource on or near direct heat or expose to sunlight Do not place the PowerSource in or around flammable environments Operating tips NOTE The PowerSource is not designed to run products that provide heat such as hair dryers or irons Protective features Low battery alarm An alarm will sound when the voltage from the battery drops to 10 6v DC This indicates that the battery the PowerSource is connected to will require recharging If connected to a vehicle battery starting the vehicle engine should be sufficient The PowerSource will automatically shutdown if its voltage is allowed to drop to 10v or
4. Powering Specifications PowerSource Model RINV500 Max Continuous power Watts 500w 1 2 hour 400w 4hrs Peak Power Watts 0 01 Seconds 800w No load current draw AMPS lt 0 2A Waveform Modified Sine Cable length Im Cable diameter 7mm Efficiency Approximately 90 Input Voltage Range 10 15v DC AC Socket 3 Pin Mains BS Approved Fuse 35 amps x2 Weight kgs 1 5 Dimensions mm Percentage of battery power converted to mains voltage power Troubleshooting Guide Symptom AC appliance will not operate the audible alarm is sounding AC appliance will not operate the audible alarm is not sounding Run time is less than expected 230 x 107 x 60 Possible causes 1 Battery has discharged to 10v 2 The inverter has overheated This could be due to poor ventilation 3 Poor battery condition 1 Inverter is overloaded 2 Internal fuses have blown 1 Battery is not fully charged 2 AC appliance power consumption is higher than expected Does not include packaging Possible solution urn off the inverter on off switch and recharge the battery urn off the inverter and allow to cool for 10 mins Replace battery Reduce load not exceeding maximum rating Fuse replacement qualified electrician only Recharge the battery Check AC appliance wattage rating is within scope of inverter For further assistance Technical Helpline
5. current to operate the load the item you require to power The power supply may be a battery or a regulated DC power supply In order to find out if your power supply is big enough divide the power consumption of the load in Watts by the voltage 12v DC in the case of the PowerSource this will give you the current in amps that the power supply must deliver EXAMPLE Load is rated at 100 watts Power supply must be able to deliver 100 12 8 3 amps CAUTION THE RINV500 MUST ONLY BE CONNECTED TO BATTERIES OR REGULATED POWER SUPPLY WITH A NOMINAL DC OUTPUT VOLTAGE OF 12 VOLTS THE POWERSOURCE WILL NOT OPERATE ABOVE 15 VOLTS CAUTION DO NOT USE WITH POSITIVE GROUND ELECTRICAL SYSTEMS IF USING DIRECTLY FROM VEHICLE BATTERY The majority of modern cars have negative ground electrical systems If you are in any doubt please check with a qualified auto electrician or your local vehicle main dealer Connecting to power supply RINV500 Switch off the RINV500 PowerSource The RINV500 PowerSource comes complete with two cables that are to be connected onto the back of the PowerSource using the sockets Do not over tighten and check no wire is exposed Observe correct polarity Red positive Black negative The other end with the crocodile clips are then clamped to the battery terminals again be sure to observe the correct polarity Connecting your PowerSource Connect the PowerSource input to the vehicle leisure battery using the
Download Pdf Manuals
Related Search
Related Contents
installation, operating, G1 G2 G3 G2 trifecta Installation 012_ARGUS 3uplus_Manual_D_V_1_00 Indicaciones importantes sobre el catálogo y el índice de imágenes Fluke 80T-150U User's Manual Manual Disponível Medidor portátil de LCR com exibição dupla Agilent S3C84H5/F84H5 Seconde Communication 省エネ簡易設置温水循環床暖房システム 「らくらく床暖」 PRESS Memup Regular BAG Copyright © All rights reserved.