Sollatek ULTIMA 400,600,800 Uninterruptible Power Supply

image

Contents

1. Battery replacement sounding every 2 seconds discharge This should be done more often if storage temperature exceeds 25 C Try to store use in a cool dry place Do not expose to excessive hot or cold i e outside the range 10 35 C ambient temp To prolong battery life try to avoid the complete discharge of your battery before recovery charge Do not discharge a battery deeper than you have to Do not attempt to dismantle a battery They do not require topping up Do not incinerate batteries Always recycle old batteries To avoid the risk of shock do not touch the terminals Keep terminals free from dirt and corrosion Do not short the connections Always charge in a ventilated area PROTECTION PHYSICAL WEIGHT ENVIRONMENT Fault Full protection Dimension mm DxWxH Net weight Operating environment continuously sounding discharge overcharge and overload protection 330 x 100 x 140 5kgs 6kgs 6 5kgs 0 40 C 0 90 relative humidity non condensing INTERFACE USB Noise level Less than 40dB RS 232 Windows Sun Solaris IBM Aix Compag True64 UnixWare FreeBSD HP UX Linux MAC Windows 98 2000 ME XP Ultima battery back up times in minutes 200VA 300VA 400VA 600VA 1000VA 1200VA 1400VA 1600VA 1800VA e Always use a suitable charging device If unsure contact your distributor Ultima 400 8 lt 1 A 3 Ultima 600 15 lt 5 lt 1 e
2. and find the UPS Note The power switch must be kept in the ON position otherwise the UPS will be disabled and your equipment will not be protected during a power failure Note If you change your UPS model please ensure you uninstall and reinstall the Software AN CHARGE THE UPS AT LEAST 8 HOURS BEFORE USE ENSURING THE BATTERY LEVEL INDICATOR IS FULL Proper care of batteries Do not subject the battery to heavy vibration or mechanical shock When you receive a new battery charge fully before use Full capacity will be reached after 2 or 3 full charge discharge cycles To obtain maximum life always store batteries in a charged state When storing batteries re charge every 6 months to prevent damage through self Specifications CAPACITY VA W 400VA 240W 600VA 360W 800VA 480W INPUT Voltage 120VAC or 220 230 240VAC Voltage range 85 140VAC or 162 290VAC Frequency 45 65 Hz auto sensing OUTPUT Voltage 120 220 230 240VAC Voltage regulation batt mode 10 Frequency 50Hz or 60Hz Frequency regulation batt mode 1 Hz Output waveform modified sinewave BATTERY Battery type 12V 4 5Ah x 1 12V7Ah x 1 12V9Ah x 1 Recharge time 8 hours to 90 after complete discharge TRANSFER TIME Typical 2 6 ms INDICATOR AC mode green lighting Backup mode green flashing AUDIBLE ALARM Backup mode sounding every 10 seconds Low battery sounding every second Overload sounding every 0 5 second
3. or surge suppressor to the UPS e Do not attach non computer related items such as medical equipment laser printers life support equipment microwave ovens or vacuum cleaners to the UPS e To reduce the risk of overheating the UPS do not cover the UPS cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces e Unplug the UPS prior to cleaning and do not use liquid or spray detergent e Do not dispose of batteries in a fire as they may explode e Do not open or mutilate the battery or batteries Released electrolyte is harmful to the skin and eyes It may be toxic A battery can present a risk of electrical shock and high short circuit current The following precautions should be observed when working on batteries 1 Remove watches rings or other metal objects from the hands 2 Use tools with insulated handles 3 Wear rubber gloves and boots 4 Do not lay tools or metal parts on top of batteries 5 Disconnect charging source prior to connecting or disconnecting batteries terminals e Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions Keep unauthorised personnel away from batteries e When replacing batteries replace with the same number and type of sealed lead acid battery The maximum ambient temperature rating is 40 e This pluggable type A equipm
4. Replace only with Sollatek recommended replacement batteries Ultima s0 E 7 T If unsure contact your distributor Battery replacement WARNING Disconnect all sources of supply before replacing battery e Replace only with Sollatek recommended replacement batteries 2 RETURN UPS UNIT TO ITS CORRECT POSITION If unsure contact your distributor The top half of the casework will now lift off The front fascia will now hinge down revealing battery Gently pull out the battery Disconnect the two wires yon a ee Cee UNIT URSIDE that are connected to the UPS To reassemble the fascia C ensure the 2 lugs are located correctly Locate 4 screws on underside of UPS unit and remove a Replacement battery installation is the reversal of this ugs procedure Ensure the wires on the battery are connected back eee exactly the way they were connected originally Caution UPS may get damaged if these wires are connected incorrectly if in doubt contact Sollatek Troubleshooting guide Problem Possible Cause Solution No LED display on the front panel 1 Battery weak 2 Battery defect 3 Power switch is not pressed 1 Re charge battery up to 8 hours 2 Replace with the same type of battery 3 Press the power switch again Alarm buzzer beeps continuously when AC supply is normal UPS overload Verify that the load matches the UPS capability specified in the specs When power failure back up time is shorte
5. Sollatek ULTIMA 400 600 800 Uninterruptible Power Supply USER INSTRUCTIONS AN CHARGE THE UPS AT LEAST 8 HOURS BEFORE USE ENSURING THE BATTERY LEVEL INDICATOR IS FULL liil AH Installation Important safety instructions WARNING IMPORTANT UPON RECEIPT THE UPS SHOULD BE CONNECTED TO THE MAINS AND ALLOWED TO CHARGE ITS BATTERY FOR AT LEAST EIGHT HOURS BEFORE IT CAN BE EFFECTIVELY USED AS A BACKUP SYSTEM e This UPS utilises voltages that may be hazardous Do not attempt to disassemble the unit The unit contains no user serviceable parts Only factory service personnel may perform repairs e Internal battery voltage is 12Vdc Sealed lead acid 6 cells battery e Connection to any other type of receptacle other than a two pole three wire grounded receptacle may result in shock hazard as well as violate local electrical codes e Inthe event of an emergency press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS e Do not allow liquids or any foreign objects to enter the UPS Do not place beverages or any other liquid containing vessels on or near the unit e This unit is intended for installation in a controlled environment temperature controlled indoor area free of conductive contaminants Avoid installing the UPS in locations where there is standing or running water or excessive humidity e Do not plug the UPS input into its own output e Donot attach a power strip
6. ces should the cover be removed as dangerous voltages can be produced even when the UPS is not connected to mains Inspection Inspect the UPS upon receipt Notify the carrier and dealer if there is damage The packaging is recyclable save it for reuse or dispose of it properly Placement Install the UPS unit in any protected environment that provides adequate airflow around the unit and is free from excessive dust corrosive fumes and conductive contaminants Do not operate your UPS in an environment where the ambient temperature or humidity is high Place the UPS away from the monitor at least 20cm to avoid interference Charging This unit is shipped from the factory with its internal battery fully charged However some charge may be lost during shipping and the battery should be recharged prior to use Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 8 hours with no load no electrical devices such as computers monitors etc connected Load connection Connect the loads PC etc to the sockets on the rear panel of the UPS before connecting the UPS to the mains The UPS can be used as a master on off switch for all the connected loads If this is desired the loads should be left switched on Never connect a laser printer to the UPS as damage may result Connect to mains Connect the UPS to the mains using the mains cable supplied with your PC or monitor A ma
7. ent with battery already installed by the supplier is operator installable and may be operated by laymen During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3 5mA Attention hazardous through electric shock Also with disconnection of this unit from the mains hazardous voltage may still be accessible through supply from battery The battery supply should therefore be disconnected in the plus and minus pole of the battery when maintenance or service work inside the UPS is necessary e The mains socket outlet that supplies the UPS should be installed near the UPS and should be easily accessible e Electrical Energy Hazard The battery pack contains HIGH ENERGY To reduce the risk of electric shock use caution when you handle and interconnect the units e If operating the UPS while it is unplugged from the source of electrical power DO NOT make contact with the line cord input pins Electrical shock hazard exists e To reduce the risk of fire or electric shock install in a temperature and humidity controlled indoor area free of conductive contaminants e DO NOT plug laser printers into a UPS The high surge currents they produce can disrupt any manufacturer s UPS Introduction The Ultima is a multi functional UPS and specially designed for a personal computer Its light weight and compact design perfectly fits within a limited worki
8. ins IEC cable is not provided with the UPS but can be ordered separately Turn on off To turn on the UPS unit press the power switch lightly To turn off the UPS unit press the power switch again Data line surge suppression optional Connect the incoming telephone cable from the wall socket to the Comms Surge Protection IN socket Using a telephone cable connect Comms Surge Protection OUT socket to your PC modem DC Start All Ultima Series are equipped with DC Start To start the UPS when AC utility power is not available simply press the power switch Functional Description LED INDICATORS In AC Mode Green Light on Backup Mode Green Flashing Power ON OFF Switch RS232 Comm Port USB Comm Port Telecom inlet Modem phone line Surge protection Surge protected Not backed up Three IEC 320 Receptacles Modem Green Power Function Ultima UPS is equipped with green power function For saving power and protecting battery this method of deep discharging protection is adopted on inverter mode Free power monitoring software on CD Choose the operation system you need and follow the instructions described on the CD to install the software Note If you find the communication unsuccessful after monitoring software installation you have to switch the Auto Search on and you can only do that if you go into Act as Administrator Once selected the software will hunt for
9. ned 1 Overload of the UPS 2 Battery voltage is too low 3 Battery defect due to high temperature operation environment or improper operation to battery 1 Remove some noncritical load 2 Charge battery 8 hours or more 3 Replace with the same type of battery Communication lost between UPS and computer 1 Software is not properly installed 2 Interface cable is not properly connected 1 Check the setting of the software 2 Check the interface cable is properly connected to the COM1 COM2 of the computer and confirm the setting again Mains normal bottom but UPS is not working 1 Fuse is blown 2 Power cord is loose 1 Replace with the same type of fuse 2 Reconnect the power cord properly Sollatek UK Ltd Unit 10 Poyle 14 Industrial Estate Newlands Drive Horton Road Poyle Slough Berkshire SL3 ODX UK Tel 44 0 1753 688300 Fax 44 0 1753 685306 Technical support support sollatek com Sales sales sollatek com www sollatek com Rev no 1 0 April 07 Sollatek UK Limited 1996 All Rights Reserved SOLLATEK and the SOLLATEK device are the trade marks of the Sollatek group of companies the power to protect
10. ng environment The Ultima UPS is equipped with boost and buck AVR to stabilise the input voltage range Itis also has built in DC start function to enable the UPS to be started up without AC power supplied Despite its compact dimensions the UPS is equipped with Smart RS 232 and USB communication ports to offer users more flexibility of connection The power monitoring software helps users monitor the status of the UPS The main features of Ultima UPS are listed below e Microprocessor controlled line interactive UPS e Automatic Voltage Stabiliser with two boost and one buck taps e RS232 and USB communications port with software for controlling the PC for safe shutdown and UPS parameter reporting via user friendly interface e Unique system for charging battery even during a brown out If the load is off e Short circuit and overload protection e Cold start feature for load shedding environments e Bad battery detection and advance replacement notification 3 months ahead e Free power monitoring and PC shutdown software included e Green power function for energy saving e DCstart function e Auto restart while AC recovery e Compact size and light weight e Provides modem phoneline surge protection Safety precautions Please read this manual fully before installing and operating the UPS Keep the manual in a safe place as it includes important information about installation maintenance and troubleshooting Under no circumstan