Home

Data Sheet - Orion Telecom Networks

image

Contents

1. Ordering Information S No 1 Part No VCL ETH E1 AC Product Description VCL Ethernet over 1 E1 IP over TDM 10 100M over 1 El Interface conversion bet G 703 E1 FE1 and each 10BaseT Ethernet over E1 TDM Desktop Metal case 1U High Version Half 19 inch Supports 1 x Ethernet 100Mbps Electrical RJ45 F 1 x E1 FE1 1200 RJ45 F E1 75Q BNC F both options 1 x 220V AC Power Supply Input 1 x System Core Cables Installation Accessories Documentation System User Manual etc Set Suitable for Point to Point application and also works with our Point to Multi Point unit on other side VCL ETH E1 DC VCL Ethernet over 1 E1 IP over TDM 10 100M over 1 E1 Interface conversion bet G 703 E1 FE1 and each 10BaseT Ethernet over E1 TDM Desktop Metal case 1U High Version Half 19 inch Supports 1 x Ethernet 100Mbps Electrical RJ45 F 1x E1 FE1 1200 RJ45 F E1 75Q BNC F both options 1 x 48V DC Power Supply Input 1 x System Core Cables Installation Accessories Documentation System User Manual etc Set Suitable for Point to Point application and also works with our Point to Multi Point unit on other side Note Operation and maintenance of network equipment require professional knowledge and experience We recommend the equipment to be managed only by qualified technicians Should you require technical assistance please consult
2. Example VCL gt showelalarm FORMAT showelalarm lt EXPLANATION gt View E1 alarm lt PARAMETER gt none Detailed CLI Command To view system software and hardware version FORMAT showversion lt EXPLANATION gt View software and hardware version PARAMETER none Example VCL gt showversion IC version V1 000 Hardware version V1 12 Software version V1 00A1 Orion Telecom Networks Inc 2014 13 VCL ETH E1 To View E1 alarm lt FORMAT gt showetalarm lt EXPLANATION gt View E1 alarm PARAMETER none Example VCL gt showelalarm ALARM LOS LOF AIS CRC Status 0 0 0 0 Description 1 Alarm 0 No alarm To Configure Ethernet Port lt FORMAT gt seteth lt AN gt lt speed gt lt duplex gt lt flow gt lt EXPLANATION gt Configure the Ethernet port Speed Mode Auto Negotiation lt PARAMETER gt AN 0 1 Autotiation 0 AN not done 1 AN done speed lt 0 1 gt 0 10Mbit s 1 100Mbit s duplex lt 0 1 gt 0 half duplex 1 full duplex flow lt 0 1 gt flow control capability O disable 1 enable Example VCL gt seteth 1111 AN Speed Duplex Flow Auto 100M Full Enable To View Ethernet Port Status lt FORMAT gt showeth lt EXPLANATION gt View Ethernet port status lt PARAMETER gt none Example VCL gt showeth AN Speed Duplex Flow Status Not Auto 10M Half Disable Connected To View Framing Status lt FORMAT gt showframe lt EXPLANATION gt View framing status
3. Orion Telecom Networks Inc 2014 2 VCL ETH E1 Index INDEX Particulars 9 Product Overview Typical Application Point to Multi Point Application with VCL ETH 8 16 ML Technical Feature Alarms and Indicator Monitoring E1 Interface Specifications Ethernet Port specifications Clock Encapsulation Installation Open up and Commissioning T Qualifying the network 2 Grounding 3 Installation Function Description 1 Front panel 2 Back View with 220V AC power Input 3 Back View with 48V DC power Input 4 5 E1 Bandwidth Selection E1 Pinout Details CLI Commands General Parameters 1 Power Supply 2 Service conditions 3 Dimensions 4 Ordering Information Support M VA ELECTROSTATIC SENSITIVE DEVICES 71 DO NOT OPEN OR HANDLE A 4 A EXCEPT ATA STATIC FREE WORKSTATION Orion Telecom Networks Inc 2014 3 VCL ETH E1 Product Overview The VCL ETH E1 Interface Converter Desktop Version provides the user with Ethernet over E1 conversion enabling the user to transport Ethernet data over an E1 link MM The equipment can be installed and used in VCL ETH E1 pairs with one terminal being installed at either end of the network This equipment can also be used with VCL ETH 8 ML and VCL ETH 16 ML 8E1 16E1 ponit to point IP over TDM product to meet various application requirements The VCL ETH E1 Interfa
4. PARAMETER none Orion Telecom Networks Inc 2014 14 VCL ETH E1 Example VCL gt showframe Frame status Frame PCM30 31 status PCM31 To View Synchronization Clock lt FORAMT gt showclock lt EXPLANATION gt View E1 clock mode lt PARAMETER gt none Example VCL gt showclock E1 Clock Master To View Encapsulation Mode lt FORAMT gt showencapmode lt EXPLANATION gt View encapsulation mode lt PARAMETER gt none Example VCL gt showencapmode The encapulation mode is HDLC To Configure GFP lt FORMAT gt setgfp lt PFI gt lt EXI gt lt PSCRD gt lt HSCRD gt lt EXPLANATION gt Configure PFI EXI PSCRD and HSCRD of GFP PARAMETER PFI 0 1 EXI 0 15 PSCRD 1 enable O disable HSCRD 1 enable O disable Example VCL gt setgfp 0 0 1 1 PFI 0 EXI 0 PSCRD Enable HSCRD Enable Orion Telecom Networks Inc 2014 15 VCL ETH E1 To View GFP Configurations lt FORMAT gt showgfp lt EXPLANATION gt View the PFI EXI PSCRD and HSCRD of GFP lt PARAMETER gt none Example VCL gt showgfp PFI 0 EXI 0 PSCRD Enable HSCRD Enable GFP SYNC Alarm General Power Supply AC Mains Input 220V AC Optional DC Mains Input 48V Power Consumption lt 4 Watts Service Conditions Ambient temperature 0 C 50 C Relative humidity 90 at 35 C Dimensions 238mm x 125mm x 44mm Weight 980gm Orion Telecom Networks Inc 2014 16 VCL ETH E1
5. 3 Parity None 4 Stop bits 1 5 Flow control None E1 120 RJ 45 Pinout Details PIN No Definition of function Signal Direction 1 TX transmitted data E1 Data Output 2 TX transmitted data E1 Data Output 4 RX received data E1 Data Input 5 RX received data E1 Data Input Others NC Ethernet RJ 45 Pinouts PIN No Definition of function Signal Direction 1 TX transmitted data Data Output 2 TX transmitted data Data Output 3 RX received data Data Input 6 RX received data Data Input Others NC Orion Telecom Networks Inc 2014 12 VCL ETH E1 CLI Commands List After entering into the application program for CLI command please key in the command line to get the list of the commands VCL gt Command Description Help To get a list of the command s for the system showversion View software and hardware version showelalarm View E1 alarm seteth Configure the Ethernet port Speed Mode Auto Negotiation showeth View Ethernet port status showframe View framing status showclock View E1 clock mode showencapmode View encapulation mode setgfp Configure PFI EXI PSCRD and HSCRD of GFP showgfp View PFI EXI PSCRD and HSCRD of GFP More help for a particular CLI command For detailed command format please key cmdname or help cmdname VCL gt cmdname enter OR VCL gt help cmdname enter
6. em CN aa 12 hie orm and mw k Working Mode Switch Setting TSO TS1 15 17 31 TS16 Unframed PCM 31 ON ON ON Framed CCS PSM 31 OFF Occupied timeslot ON Multi Framed CAS PCM 30 OFF Occupied timeslot ON OFF Note Fractiona E1 FE1 bandwidth is effective only if the encapsulation mode is set to HDLC GFP HDLC switch is set to ON Example 1 If you wish to use only first 5 time slots then you need to set the TSO time slots to OFF and switch TS1 to TS5 to ON and time slot TS16 will be set to ON Example 2 If you wish to carry first 8 time slots on 512Kbps then you need to set the TSO time slot OFF and switch TS1 to TS8 to ON i e since each time slot consumes 64Kbps so 8 time slots will consume 8 x 64Kbps 512Kbps and time slot S16 will be set to ON Example 3 If you wish to carry 20 time slots on 1 28Mbps 64Kbps x 20 then you need to set time slot TSO OFF and TS1 to TS21 time slots to ON Please remember that the time slot TS16 will be used as signaling time slot Orion Telecom Networks Inc 2014 11 VCL ETH E1 Console RJ 45 Pinout Details PIN No Definition of function Signal Direction 6 GND Signal Ground 7 RX received data RS232 Signal Input 8 TX transmitted data RS232 Signal Output Others NC HyperTerminal settings should be as follows 1 Bits per second 19200 2 Data bits 8
7. in full duplex mode OFF Ethernet port is running in half duplex mode LOOP ON Yellow system is in test mode OFF Normal operation mode ERR ON Red Error in BER test E1 Signal OFF BER test OFF or has no errors Switch Status Description MASTER ON local timing OFF tracing E1 line TEST ON line error testing Led ERR show the testing result OFF turn off line error test function GFP HDLC ON HDLC framing OFF GFP framing Orion Telecom Networks Inc 2014 9 VCL ETH E1 Back View with 220V AC Power Input Input E1 Port Output Ethernet AC 220V ON OFF E175Q 120Q E1 75Q Port Inlet Switch Back View with 48V DC Power Input Ground Positive Negative Input E1 Port Output Ethernet p ON OFF E1750 1200 E1750 Port Switch 48V DC Inlet Tag Description IN 750 Represents the unbalanced E1 750 input BNC OUT 75Q Represents the unbalanced E1 75 Output BNC 1200 Represents the balanced E1 1200 input output RJ 45 ETH Fast Ethernet interface RJ 45 220V Represents AC 220V inlet 48V Represents DC 48V inlet Orion Telecom Networks Inc 2014 10 VCL ETH E1 E1 Bandwidth Selection For E1 bandwidth selection Effective only if the encapsulation mode is set to HDLC i e GFP HDLC switch is set to ON the DIP Switch settings on the right side panel are as follows OFF ON c me m aa 7 8 nm ef _ en er E 3 ag 5 7 We T522 2 1523 o
8. the ethernet interfaces of the devices that are connected to the Ethernet over E1 equipment Connect the ethernet links The equipmentis used to bridge two LANs Please ensure that the LANs on both sides of the link are operating in the same IP domain Step 4 Ping over the ethernet connection from one side to the other near end to the far end to verify that the Ethernet connection has been established between the two LANs After succeeding in ping the user may also check the integrity of each E1 link by connecting E1 link and then transporting ethernet data over that E1 link In the event that the equipment resets repeatedly or lots of frame errors are noticed recheck the connection between E1 cable and interface converter or E1 cable and transmission device Orion Telecom Networks Inc 2014 VCL ETH E1 Description of the Front Panel Configuration Configuration Console Port Switches Switches Definition of Indicators on Front Panel LED Status Description PWR ON Green system is powered OFF System is not powered RA ON Red remote alarm indication OFF OK LOS ON Red Loss of E1 alarm indication OFF OK LOF ON Red Loss of E1 frame indication OFF OK AIS ON Red AIS alarm idication OFF OK CV ON Red E1 code violation alarm indication OFF OK LINK ON Green LAN port connection Normal OFF No LAN connection on Ethernet port FDX ON Green Ethernet port is running
9. the provider or contact our SUPPORT DESK at helpdesk oriontelecom info Technical Specifications are subject to change without notice Windows is the registered Trademark of Microsoft Corporation USA Revision 05 January 12 2014 Headquarters Phoenix Arizona Orion Telecom Networks Inc 20100 N 51stAve Suite B240 Glendale AZ 85308 Phone 1 480 816 8672 Fax 41 480 816 0115 E mail sales oriontelecom com Regional Office Miami Florida Orion Telecom Networks Inc 4000 Ponce de Leon Blvd Suite 470 Coral Gables FL 33146 U S A Phone 1 305 777 0419 Fax 1 305 777 0201 E mail sales oriontelecom com Website http www oriontelecom com Website http www oriontelecom com Orion Telecom Networks Inc 2014 17
10. CL ETH E1 point to point protocol if fractional E1 is used to carry payload GFP GFP Mode is must to use the VCL ETH E1 in point to multi point Protocol with Deluxe models VCL ETH 4 8 16 and VCL ETH 8 16 ML Orion Telecom Networks Inc 2014 VCL ETH E1 Installation and Commissioning 1 Qualifying the Network e Please ensure that the error code rate each of the E1 circuits connecting to the equipment is lower than 107 e The transmission time delay difference between the various E1 circuits shall not exceed 8ms e The Ethernet wire type shall be crossover when connecting with PC and straight through when connecting to an Ethernet switch HUB The length of the ethernet cable shall not exceed 100m 2 Grounding e When the device is used with the AC 220V power supply the 3 core socket must be grounded forprotection e The other equipment connected with the converter shall also be grounded to earth for protection 3 Installation Step1 Power up the equipment Please ensure that equipment is powered up prior to connecting the Ethernet and the E1 links Step 2 ConnectE1 line on the premise that transmission device interface converter and Ethernet converter have safely grounded BER test may be conducted on each E1 link using a BERT tester to ensure that the E1 errors are within the permitted limits threshold Step3 Please configure the ethernet mode of the Ethernet over E1 equipment at both sides as well as
11. TELECOM NETWORKS ORION TELECOM NETWORKS INC VCL ETH E1 Ethernet over E1 Converter Data Sheet amp User Manual Headquarters Phoenix Arizona Orion Telecom Networks Inc 20100 N 51stAve Suite B240 Glendale AZ 85308 Phone 1 480 816 8672 Fax 1 480 816 0115 E mail sales oriontelecom com Website http www oriontelecom com Regional Office Miami Florida Orion Telecom Networks Inc 4000 Ponce de Leon Blvd Suite 470 Coral Gables FL33146 U S A Phone 1 305 777 0419 Fax 1 305 777 0201 E mail sales oriontelecom com Website http www oriontelecom com VCL ETH E1 Notice Warranty This Orion product is warranted against defects in material and workmanship for a period of one year from the date of shipment During the warranty period Orion will at its discretion either repair or replace products which prove to be defective For warranty service or repair this product must be returned to a service facility designated by Orion The buyer shall prepay shipping charges to Orion and the company shall pay shipping charges to return the product to the buyer However the buyer shall pay all the shipping charges duties and taxes for products returned to Orion from another country Limitation of Warranty The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by the buyer the buyer supplied firmware or interfacing unauthorized modification or misuse operation
12. ce Converter is an Ethernet extension device utilizing TDM telecom infrastructure the telecom network of Es or of PDH SDH and E1 E3 SDH microwave etc carrying E1s It converts the Ethernet data into E1 frame format for transmission over the existing TDM E1 links and then re converts the E1 back into Ethernet data the far end terminal to BRIDGE two Ethernet LANs over the existing E1 based telecom network The device can effectively utilize the redundant bandwidth of telecom operators existing TDM network to transport Ethernet data with low investment Application The equipment may be used for the following purposes Bridging Ethernet LANs over existing TDM E1 telecom network s Extending Ethernet networks utilizing TDM E1 landline based telecom infrastructure Using telecom network of E1s PDH SDH microwave etc carrying E1s to transport Ethernet data Typical Applications Point to Point Application a E1 Network VCL ETH E1 VCL ETH E1 E1 E3 SDH PDH Network carrying E1 Links Orion Telecom Networks Inc 2014 4 VCL ETH E1 Point to Multi Point Application with VCL ETH 8 ML or VCL ETH 16 ML Central Site Ethernet 10 100 VCL ETH 16 ML QE Remote Site 1 Ethernet VCL ETH E1 10 100 Remote Site 2 Ethernet VCL ETH E1 10 100 Remote Site 3 Ethernet VCL ETH E1 10 100 Remote Site 4 Ethernet VCL ETH E1 E1 Upto 16E1 Chan
13. king modes of internal clock and network Loop timed clock With multiple loopback functions and built in bit error testing function it facilitates the trouble shooting Compatible to deluxe models VCL ETH 4 8 16 and VCL ETH 8 16 ML and can be installed with them to reduce the installation cost Easy to operate Power supply options 110V AC 240V AC 50 60 Hz power options available 48V DC power option available e Power consumption less than 4Watts Alarms and Indicator Monitoring Power Indicator Remote Alarm Indicator Loss of Frame Indicator E1 LOS Alarm Indicator AIS Alarm Indicator Code Violation Alarm Indicator Ethernet Link Indicator Ethernet Mode FDX Indicator Loopback Indicator Error in Test Indicator E1 Interface Specifications Line Rate E1 2 048 Mbps 50 bps Framing Un Framed PCM 30 PCM 31 Electrical As per ITU T G 703 and ITU T G 704 Jitter As per ITU T G 742 and ITU T G 823 Impedance 120 Ohm RJ 45 Impedance 75 Ohm BNC Optional Orion Telecom Networks Inc 2014 VCL ETH E1 Ethernet Port Specifications Interface Types 10 100BaseT Standards Compliance IEEE 802 3 Connectors RJ 45 10 100 BaseT Electrical MDI X Supported auto adapts cross straight cable Mode Autonegotiation Half Full 10 100M Clock Internal Master and network Slave clock Encapsulation HDLC HDLC mode is required in installation between two V
14. nels Network E1 E3 SDH PDH Network carrying E1 Links Remote Site 7 VCL ETH E1 Ethernet 10 100 Remote Site 8 VCL ETH E1 Ethernet 10 100 Remote Site 9 VCL ETH E1 Ethernet 10 100 Remote Site 10 VCL ETH E1 Ethernet 10 100 E1 1 E1 10 100 i cy LAN Remote Site 5 Remote Site 11 Ethernet VCL ETH E1 VCL ETH E1 Ethernet 10 100 E1 1 ET gomme 10 100 Remote Site 6 Remote Site 12 Ethernet VCL ETH E1 VCL ETH E1 Ethernet 10 100 E1 1 E1 10 100 Up to 12 Remote Sites Directions and 16 E1 Links Orion Telecom Networks Inc 2014 VCL ETH E1 Technical Features 1U high compact size Supports both fraction E1 FE1 and full E1 The maximum transmission rate of Ethernet data over E1 links is 2 048Mbit s E1 supports three working modes unframed framed CCS PCM 31 and multiple framed CAS PCM30 Allows transparent transmission of super long frames upto 2024 bytes Automatic discards under size less than 64 bytes and oversize more than 2024 bytes framed Ethernet interface complies to IEEE 802 3 Automatic Ethernet negotiation function Supports 10M 100M and working modes of both full duplex and half duplex Automatic straight and cross over cable support Auto MDI X Available with MAC address list filtration learning and updating functions PAUSE flow control ability in full duplex mode Equipment supports two wor
15. outside of the environmental specifications for the product or improper site preparation or maintenance Exclusive Remedies The remedies provided herein are the buyer s sole and exclusive remedies Orion shall not be liable for any direct indirect special incidental or consequential damages whether based on contract or any legal theory Notice This manual contains information that is proprietary to Orion Telecom Networks Inc No part of this publication may be reproduced in any form whatsoever without prior written approval by Orion Telecom Networks Inc Safety Warnings The exclamation point within a triangle is intended to warn the operator or service personnel of operation and maintenance factors relating to the product and its operating environment which could pose a safety hazard Always observe standard safety precautions during installation operation and maintenance of this product Only qualified and authorized service personnel should carry out adjustment maintenance or repairs to this instrument No adjustment maintenance or repairs should be performed by either the operator or the user Qus ASSURANCE PROGRAM Orion s products are designed and manufactured under a strict Quality Assurance Program based on the ISO 9001 2008 14001 2004 philosophy and principles Orion pays very special attention to its vendor development program which ensures an end product ofthe highest quality at the most cost effective prices