1. User s Guide EXT S _ INSTRUMENTS A FLIR COMPANY Heavy Duty Digital Light Meter with PC Interface Model HD400 Introduction Congratulations on your purchase of the Extech HD400 Digital Light Meter The HD400 measures illuminance in Lux and Foot candles Fc The HD400 includes a PC interface and Windows compatible software for real time monitoring and storage of light level data This meter is shipped fully tested and calibrated and with proper use will provide years of reliable service Features Precision instrumentation for the measurement of light illuminance Large 4000 count backlit LCD display with fast 40 segment bargraph Data Hold function Meets CIE Photopic spectral response Fully cosine corrected for angular incidence of light Automatic correction factoring for non standard lighting types Stable long lasting silicon photo diode sensor with spectral response filter Fast responding High accuracy Automatic zero function Peak Hold function for capturing fast changes in light levels down to 10uS Auto power off after 20 minutes of inactivity Maximum and Minimum light level memory Relative reading feature USB PC Interface for Data acquisition Four 4 range levels Heavy Duty rugged double molded housing 2 HD400 V2 0 5 08 Description Meter Description 1 8 NOTE The battery compartment tripod mount and Sensor cable plug shown co
2. ailed software instructions HD400 Connected Pier RealTime Owalo O ComPortic Gah WET vet Hebe sacrer 6 HD400 V2 0 5 08 Specifications Range Specifications Units Lux Foot candles Notes 1 Sensor Calibrated to standard incandescent lamp color temperature 2856K 2 1Fe 10 76 Lux General Specifications Display Ranging Over range indication Spectral response Spectral accuracy Cosine response Measurement Repeatability Display rate Photo detector Peak capture Operating conditions Storage conditions Meter Dimensions Detector Dimensions Weight Sensor lead length Low battery indication Power supply Range Resolution Accuracy 5 rdg 10 digits 10 rdg 10 digits 5 rdg 10 digits 10 rdg 10 digits 4000 count LCD display with 40 segment bargraph Four ranges manual selection LCD displays OL CIE photopic VA function f4 6 f2 2 Cosine corrected for angular incidence of light 3 Approximately 750 msec for digital and bargraph displays Silicon photo diode with spectral response filter 10uS minimum Temperature 32 to 104 F 0 to 40 C Humidity lt 80 RH Temperature 14 to 140 F 10 to 50 C Humidity lt 80 RH 6 7 x 3 1 x 1 6 170 x 80 x 40mm 4 5 x 2 4 x 0 8 115 x 60 x 20mm Approx 13 7 oz 390g with battery 3 2 1m Battery symbol appears on the LCD 9V battery 7 HD400 V2 0 5 08 Ma
3. intenance Cleaning The meter and its sensor can be cleaned with a damp cloth A mild detergent may be used but avoid solvents abrasives and harsh chemicals Battery Installation Replacement The battery compartment is located on the back of the meter The compartment is easily accessed by pressing and sliding the rear battery compartment cover off of the meter in the direction of the molded arrow Replace or install the 9V battery and close the battery compartment by sliding the compartment cover back onto the meter You as the end user are legally bound Battery ordinance to return all used batteries and accumulators disposal in the household garbage is prohibited You can hand over your used batteries accumulators gratuitously at the collection points for our branches in your community or wherever batteries accumulators are sold Disposal Follow the valid legal stipulations in respect of the disposal of the device at the end of its lifecycle Storing When the meter is to be stored please remove the battery and affix the sensor s protective cover Avoid storing the meter in areas of extreme temperature and humidity Copyright 2008 Extech Instruments Corporation a FLIR company All rights reserved including the right of reproduction in whole or in part in any form 8 HD400 V2 0 5 08
4. ion Press the RANGE button to select the measurement range There are four range selections for each unit of measure The units display and decimal point location identify the range selected Refer to the Range Specifications section of this User Guide for detailed range information Taking a Measurement 1 Remove the sensor s protective cap to expose the white sensor dome 2 Place the sensor in a horizontal position under the source of light to be measured 3 Read the illuminance measurement on the LCD display 4 The meter will display OL when the measurement is outside of the meter s specified range or if the meter is set to the wrong range Change the range by pressing the RANGE button 5 Replace the protective sensor cap when the meter is not in use Data Hold To freeze the LCD display momentarily press the HOLD button MANU HOLD will appear on the upper left hand side of the LCD Momentarily press the HOLD button again to return to normal operation MANU HOLD will switch off Peak Hold The Peak Hold function allows the meter to capture short duration light flashes The meter can capture peaks down to 10uS in duration 1 Press the PEAK button to activate the Peak Hold feature MANU Pmax will appear on the display Press the PEAK button again and MANU Pmin will appear Use Pmax to capture positive peaks Use Pmin to capture negative peaks 2 To exit the Peak Hold mode and return to the n
5. ipped with a backlight feature that lights up the LCD display 1 2 Press the backlight button to activate the backlight Press the backlight button again to switch the backlight off Note that the backlight will turn off automatically after a short period of time in order to save battery energy The backlight function uses extra battery energy To conserve energy use the backlight feature sparingly 5 HD400 V2 0 5 08 USB PC Interface Description The HD400 meter can be connected to a PC via its USB interface A USB cable along with Windows software is included with the meter The software allows the user to view store and print readings from the PC Note that the HD400 does not datalog readings meaning that it does not store readings in an internal memory it simply displays readings on the PC as they are taken in real time after which the readings can be analyzed stored as text or printed Meter to PC Connection The supplied USB cable is used to connect the meter to a PC Connect the smaller connector end of the cable to the meter s interface port located under the tab at the left hand side of the meter The larger connector end of the cable connects to a PC USB port Program Software The supplied software allows the user to view readings in real time on a PC The readings can be analyzed zoomed stored and printed Please refer to the HELP UTILITY available from inside the software program for det
6. nnected to meter jack USB jack for PC interface under the flip down cover LCD Display Upper Push Button set Lower Push Button set Sensor s light collector dome Sensor housing protective cover not shown Power ON OFF button tilt stand are located on the rear of the instrument and are not pictured Display Description 1 Gon fo oP YO N 0CU oOo Digital measurement reading Bargraph measurement reading Auto Power OFF active icon MANU icon 3 1 7 I r DATA HOLD icon N I l p 2 x wit LUTA i H OU ae Uo UU PC connection icon RELATIVE mode icon MAXIMUM and MINIMUM reading mode Range units of measure 9 10 11 3 HD400 V2 0 5 08 Operation Meter Power 1 Press the Power button to turn the meter ON or OFF 2 Ifthe meter does not switch on when the power button is pressed or if the low battery icon is displayed on the LCD replace the 9V battery Auto Power Off APO 1 The meter is equipped with an automatic power off APO feature that turns the meter off after 20 minutes of inactivity 2 To defeat the APO feature press and hold the APO button While holding down the APO button press the RANGE button to switch off the circular APO symbol on the upper left hand corner of the LCD Repeat this step to re activate the APO feature The APO icon will reappear Unit of Measure Press the UNITS button to change the unit of measure from Lux to Fc or from Fc to Lux Range Select
7. ormal operating mode press the PEAK button a third time 4 HD400 V2 0 5 08 Maximum MAX and Minimum MIN Reading Memory The MAX MIN function allows the meter to store the highest MAX and lowest MIN readings 1 Press the MAX MIN button to activate the feature MANU MAX will appear on the top of the display and the meter will only display the highest reading encountered Press the MAX MIN button again MANU MIN will appear on the top of the display and the meter will only display the lowest reading encountered To exit this mode and return to the normal operating mode press the MAX MIN button a third time Relative Mode The Relative Mode function allows the user to store a reference value in the meter for which to compare subsequent readings For example if the user stores a reading of 100 Lux all subsequent readings will be displayed as actual reading minus 100 1 Take the measurement and when the desired reference value is displayed press the REL button MANU REL will appear at the top of the LCD display All subsequent readings will be offset by the by an amount equal to the reference level For example if the reference level is 100 Lux all subsequent readings will equal the actual reading plus 100 Lux To exit the Relative Mode press the REL button MANU REL will switch off indicating that the meter has returned to the normal operating mode LCD Backlight The meter is equ

Download Pdf Manuals

image

Related Search

Related Contents

OpenBTS for dummies  Progress Lighting P5954-108 Instructions / Assembly  HD-SDI Water-proof IR Camera - Hi-view  Manuales de instrucciones  DUAL DRIVE NETWORK CENTER  User Manual Oracle Banking Digital Experience Dashboard Widgets  Samsung 80GB S-ATA  MANUEL DU KIT COURSE SS  OM, K760 Cut-n-Break, K 760 Cut-n-Break, 2010-02, JP  IOGear Q1042 User's Manual  