Contents
1. MAMA NAO WWW AXIOMET EU 4 Accuracy 200 100 C 0 2 reading 1 C 100 1300 C 0 1 reading 0 7 C 328 148 F 0 2 reading 2F 148 2372 F 0 1 reading 1 4 F Sample rate 1 time sec Auto power off about 20 minutes 5 6 7 low battery indicator 8 Operating environment 0 50 C 32 122 F 0 80 RH 9 Storage environment 20 60 C 4 140 F 0 80 RH 10 Dimension and Weight 121 L x60 W x30 H mm about 180g 11 Accessories DC1 5V AAA x 3pcs K type thermocouple wire x 2pcs String x 1 pcs Plastic box x 1 pcs User manual x 1 pcs 3 NAMES OF PARTS 3 1 Instrument familiarization 1 sensor cover 2 temperature input jack 3 LCD display 4 function key 3 2 LCD Display The meaning of the symbols represented by the following Double ways thermocouple meter Indicating it is now in the data holding state Indication to the high or low temperature setting Indication to the second function key 1 2 3 4 Type of thermocouple 5 Display zone D coda 6 Display zone KI HEO LIMIT SHIFT AG 7 8 9 1 T1 T2 Average Maximum minimize TI Indication to back light s HUHN Temperature units D r r ave MN 0 Indication to low voltage of the batteries T2 e gt Q EUG WWW AXIOMET EU 4 OPERATION INSTRUCTION NOTE After abrupt ambient temperature changes allow instrument temper
2. MODE or HOLD to select T1 or T2 ELILIIIII WWW AXIOMET EU When it is full of five data OU icon will display on the LCD If need to store more data you should clear all data which have been stored before in normal mode press the MEM key gt 2 sec then a CLEAR icon will display on the LCD LIMIT To enforce Hi Lo alarm function When SHIFT is enabled press the LIMIT key to turn the Hi Lo alarm ON or OFF HOLD 4 Light key Press the key a ta icon will display on the LCD and the readout held In Press the key once more to cancel the hold function S 1 oe Press the key gt 2 sec the back light will be turned on and the Hes icon will display on the LCD Press the key once more gt 2 sec the light will be turned off and the icon will disappeard UNIT key 5 TYPE UNIT The temperature unit selection Press the key to select alternate the two temperature units of C and F TYPE Select thermocouple type function When SHIFT is enabled press the key to select alternate the two thermocouple type of K type and J type MODE 6 HiLo key MODE The maximum minimum readout setting Hi Lo The alarm Hi Lo temperature setting When the main display temperature is higher than Hi temperature setting or lower than Lo temperature setting the alarm will continue send out When SHIFT is enabled press the Hi Lo key to enter the Hi Lo temperature setting A Use SHIFT key to select Hi or Lo setting B Use MODE or HOLD key to
3. AXIO HHH ME T DOUBLE WAYS THERMOCOUPLE METER Model AX 5003 CE USERS MANUAL HI WWw AXIOMET EU 1 INTRODUCTION Thank you for purchasing the double ways thermocouple meter from us Please take a few minutes to browse through this user manual before you begin to operate the meter to ensure that you are fully familiarized with how best to operate the meter as accurately and safely as possible This meter can match any standard type K or J sensor 1 1 Precautions safety measures To get the best service from this meter please read this user s manual carefully and observe the detailed safety precautions strictly 1 1 1 During use 1 Temperature jacks standard small thermocouple jacks the center spacing is 7 9mm between the two prongs 2 When the battery voltage is under proper operation requirement the lb symbol will show on the LCD and the battery need to be replaced with new 3 To keep the instrument clean wipe the case with a dry cloth and detergent do not use abrasives or solvents 1 1 2 Maintaining the product e Do not measure at a high temperature high humidity places e When not using the instrument for a long time please remove the battery and avoid storing in high temperature and high humidity 2 FEATURES 1 Display 4 digits LCD Display 2 Resolution 0 1 C 0 1 F below 1000 C 1 C 1 above 1000 C 3 Range K type 200 1300 C 328 2372 F J type 200 1200 C 328 2192 F
4. ature to stabilize for 20 minutes before using for measurement SHIFT 1 Put the instrument with enough battery power in the hand press the ON OFF key to turn the Power on and enter into the measuring mode 2 If the instrument is connected to the thermocouple it will display the thermocouple temperature of the port T1 or T2 Otherwise it will display OL 3 You can Press the function key to change temperature unit select T1 T2 MAX MIN HOLD mode and K J type set Hi Lo alarm and store data refer to function keys HOLD 4 Press the Light SHIFT 5 Press ON OFF key gt 2 sec To turn the power OFF If you still need more operations please see the description of function keys key gt 2 sec to turn the back light on or off 5 FUNCTION KEYS SHIFT ON OFF Power ON OFF key Press the key to turn the Power ON and Press the key once more gt 2sec to turn the power OFF SHIFT second function key Press the key to enable the second function of the key and a SHIFT icon will display on the LCD The function of key SHIFT disenable MEM MODE UNIT SHIFT enable LIMIT Hi Lo TYPE 2 T1 T2 key Press the key to enforce T1 T2 function and the T1 T2 icon will display on the LCD MEM pe 3 Limit ey MEM function Press the key to store the present reading of T1 and T2 Five groups of data can be stored at most In the mode of MEM press the key T1 T2 or UNIT to view the recorded data up and down and press the key
5. move position C Use T1 T2 or UNIT key to set temperature D Use SHIFT key to complete the setting ELILIIIII WWW AXIOMET EU NORMAL sur Huo Hi SHIFT Lo DISPLAY SETTING D SETTING SHIFT 11 72 a de MORE AT Hoo Y TYPE High The Hi Lo temperature setting Type Hi Lo K 1300 C 2372 F 200 C 328 F J 1200 C 2192 F 200 C 328 F 7 AUTO POWER OFF SETTING When the meter is powered on it is under auto power off mode The meter will power itself off after 20 minutes if no key operation Cancelled auto power off function press HOLD key when power on until the LCD display all icons and the buzzer send out a long alarm 6 MAINTENANCE 1 Cleaning Instructions The meter may be wiped down with a wet sponge or cloth using a mild water based detergent or anti bacterial soap and rinsed under a gentle stream of cold water NOTE This unit is not designed for complete submersion or washing in water 2 Battery Replacement Use the following procedure When the battery voltage drop below proper operation range the E symbol will appear on the LCD display and the battery Reed to be replaced e Press the battery cover and towards arrowhead direction to open the battery cover e Replace the battery with three new 1 5V batteries AAA e Replace the battery cover MAMA NAL WWW AXIOMET EU
Download Pdf Manuals
Related Search
Related Contents
PACSystems RX7i CRE020-KW, CPU v. 6.75, Enet v 商品仕様[PDF] la possibilité de prendre en charge eux même le suje CMS60C user manual (vet) MICROLAB PicoPress - Microlab Elettronica Sas 取扱説明書 - 日立工機 Base XML - Stern Weber (AX-4 / AX-7) - Manual de Instalação Minutas de Reunión para informes internos Copyright © All rights reserved.