1. backward toward toilet tank When finished cleansing return water flow to OFF position by moving water control stick forward Move shower head to rest position under neath the toilet s rim How to use GoBidet with Hot Water Connection Kit optional VERY GENTLY turn on and adjust water flow by moving the vertical water control stick Part no 2003 04 backward toward toilet tank Adjust water control stick left to right to choose your water temperature comfort zone VERY IMPORTANT To avoid scalding do not use only hot water F Care amp Maintenance To keep the GoBidet operating as intended clean and wipe with baby oil or a similar product when necessary using a soft cloth G Troubleshooting Removal of toilet seat is usually easily done by popping open the plastic screw covers behind the seat using a flathead screwdriver and unscrewing If screws are corroded metal and not plastic they may be difficult to remove using a traditional screwdriver In this case you should use a hacksaw blade or bolt cutter to remove screws from the toilet Be sure to protect your toilet from damage if a hacksaw is used Water will not turn on e Make sure water supply is connected AND turned on e Make sure vertical water control stick Part no 2003 04 on GoBidet is in cold water position If hot water is not installed and water control stick is in hot water position water will not flow e Make sure hose is not kinked o
2. GoBidet GoBidet Bidet Attachment Apollo Bidet 71 Ruths Place 8 Sequim WA 98382 Tel 1 800 681 0753 Fax 1 360 681 4029 www apollobidet com CONGRATULATIONS You have purchased a product made with the highest quality standards In the unlikely event that you have any problems with this unit please do NOT return your GoBidet to the purchase location Instead please contact us at 1 800 681 0753 to speak with a customer service representative who will provide friendly personal service and answer any questions you have regarding your new personal hygiene system MODEL 2003 In this box e This User Manual GoBidet Unit w mounting bracket nut rubber washer and plastic washer Plastic spacer part no 2003 11 3 8 Compression Cap w Rubber Washer part no 2003 38 3 8 Hose part no 2003 14 3 8 Nipple part no 2003 16 7 8 T valve part no 2003 18 installs on bottom of toilet INSTALLATION INSTRUCTIONS amp IMPORTANT NOTES This unit can accommodate hot and or cold water installations For cold water only install as directed For hot water installation please use the Hot Water Installation Kit Part no 2003HIK available by calling 1 800 681 0753 Your GoBidet will attach to a one piece toilet tank bowl are molded into one piece or a two piece toilet tank bowl are separate It also fits regular round or elongated toilets See Parts Breakdown page for instructions on changin
3. ad is in center of toilet Upon retraction shower arm should rest beneath rim of toilet Finish tightening bracket in place DO NOT OVER TIGHTEN BUSHING OR TOILET WILL CRACK C Hose Installation Remember to use Teflon tape on all water line connections Install the 7 8 T to the bottom of the toilet Connect the 3 8 hose to the 3 8 nipple and then connect to the bidet Connect the other end of the hose to the already installed 7 8 T valve Dry your work area completely Turn on water supply Check for leaks Final Installation Instructions If no leaks are found re install your toilet seat using existing screws and nuts If they are unusable purchase new ones at your local retailer First insert a screw through the seat and the threaded bushing Second insert the remaining screw through the seat the provided plastic spacer Part no 2003 11 and the toilet Tighten nuts onto screws Check to be sure that the seat does not rest heavily upon the shower assembly Part no 2003 01 of the GoBidet when in the down position If it does see section G Troubleshooting on page 4 E Operating Instructions While sitting on your toilet seat use the horiziontal control handle on your GoBidet to move the shower head assembly toward the center of the toilet underneath the desired area VERY GENTLY turn ON and adjust water flow by moving the vertical water control stick Part no 2003 04
4. g the bushing bracket mounting location Use Teflon tape on all connections A Disconnecting your toilet s water supply line Turn off water supply to toilet It is usually an angle stop shut off valve on wall beneath toilet Empty toilet completely by holding flush handle down Puta shallow container beneath water shut off valve at wall and water line connection at tank to catch excess water Disconnect water line from cut off valve Clean and dry fittings and threads Remove toilet seat and clean mounting area See G Troubleshooting for help Save seat mounting parts to re use After applying Teflon tape to its threads attach the nipple and hose Parts no 2003 16 and 2003 14 and tighten Determine if your toilet is a one piece or two piece unit If you havea one piece unit please follow instructions on changing bushing bracket Part no 2003 09 mounting location on Parts Breakdown page before continuing Insert threaded bushing of support bracket Part no 2003 09 into toilet bowl screw opening used for mounting toilet seat Use opening on your left when facing the toilet tank Secure to toilet by installing rubber washer first followed by plastic washer and chrome nut onto bottom of threaded bushing Finger tighten only Before tightening bushing completely move shower arm Part no 2003 01 to its maximum extension moving the support bracket Part no 2003 09 until shower he
5. r twisted Water leaks from connections e Turn water off and re seal connections with Teflon tape Turn water back on and check for leaks Repeat if necessary Water leaks from location where shower head assembly connects to GoBidet e Firmly tighten nut holding shower head assembly Part no 2003 01 to GoBidet Water leaks from GoBidet behind the bell handle assembly Part no 2003 04 e Insert screwdriver in hole at bottom of bell handle assembly and loosen set screw to remove bell handle assembly Unscrew counter clockwise direction chrome nut cover Part no 2003 24 from the front of the GoBidet housing This can usually be accomplished by hand e Tighten clockwise direction large brass nut Part no 2003 45 e Replace chrome nut cover and bell handle assembly Shower head assembly Part no 2003 01 will not move when sitting on the toilet e If you used all of the included spacers Part no 2003 11 on the side of seat without the GoBidet Step D 2 you can request more by contacting us at 1 800 681 0753 e If you cannot find taller attachable bumpers you may need a new toilet seat with taller bumpers or one with less seat contour GoBidet moves too much when manipulating the controls e Snugly tighten threaded bushing Step B 4 e Firmly tighten chrome nut holding GoBidet to mounting bracket Part no 2003 09 e In some cases you may need to also use a strong double sided tape between the mo
6. unting bracket and the bowl We recommend 3M industrial double sided tape GoBidet sprays face or the ceiling e Reposition shower head to spray desired area Mounting to one piece toilets Parts Brea kdown Swap location of plastic cap and threaded GoBidet Com ponent Parts nut bushing to position shown 2003 01 Complete Shower Assembly iS 2003 02 z3 Bidet Body Casing 2003 03 W J Single Lever Ceramic Mixer Cartridge 2003 04 Water Control Assembly Two Piece Toilet 2003 05 3 8 Plug Stop Hot Line 2003 06 10mm Flow Regulating Check Valve 2003 07 12mm Neoprene O Rings 2003 09 2003 04 Bracket w Bushing Nut amp Washer W 2003 11 2003 24 One Inch Plastic Spacer 2003 09 oD 2003 45 2003 14 R RUBBER L O 1 3 8 Hose D 7 2 2003 01 P PLASTIC ED 2003 16 2003 03 2003 06 1 3 8 Brass Nipple 2003 07 A 2003 18 2003 11 2003 05 R 2 2003 02 1 7 8 T valve 2 Y 2003 24 2003 06 Nut Cover Ring 2003 07 2003 45 Brass Retainer Nut T valve installation location MODEL 2003 Completed Assembly FOR IN DIVI DUAL PARTS CALL 1 800 681 0753 2003 14 T valve GoBidet 2003 18 2003 16