Home
IQ-MDVR - Ness Corporation
Contents
1. 53 HIGHEST SPEED IN HISTORY 406631MPH 2011 12 20 13 55 32 TOTALMILEAGE 1844674407370955MILE PGDOWN EXIT LOWEST VOLTAGE IN HISTORY 8 12V 2011 12 13 15 58 32 HIGHEST VOLTAGE IN HISTOTY 31 0V 2011 12 01 15 58 32 HIGHEST SHOCK IN HISTORY X 00 0009 2011 12 01 15 58 32 Y 00 000g 2011 12 01 15 58 32 Z 00 000g 2011 12 01 15 58 32 PGUP PGDOWN Press CLEAR to delete all the current data 3 3 4 MODULES Display the GPS module information 54 CGPSMODULE GPS SIGNAL INVALID WIFIMODULE ON WIFI SIGNAL 83dB 3 3 5 BATTERY INFO TEMPERATURE 0C VOLTAGE 0 0V CURRENT OMA AVERAGE CURRENT 0mA RELARIVE CHARGE 0 ABSOLUTE CHARGE 0 REMAIN CAPACITY OmAh FULL CAPACITY 0mAh RUNTIME TO EMP TY 0M AVERAGE TOEMPTY 0M AVERAGE TO FULL 0M CYCLE COUNT 0 CELL VOLTAGE 4 0 0V CELL VOLTAGE 3 0 0V CELL VOLTAGE 2 0 0 CELL VOLTAGE 1 0 0V 55
2. ANNA DEVICE NO 123456 UE f password is disenable press SETUP key on the handheld controller into the setup menu directly e f password is enable press LOGIN LOCK OR ENTER key on the handheld controller the setup menu will appear 123456 DEVICE NO PASSWORD DEVICE NO The unit ID of MDVR The user can setup the ID for the MDVR in the menu REGISTER 10 INFORMATION After setting the ID number will appear automatically on the login screen It s the number in the bracket PASSWORD Enter the admin password or user password Keyboard Press Enter to use keyboard to type device ID and password 1 0 9 number key press Enter to select the number 2 123 Input type shift key Number capital small letter 3 lt delete 4 1 Exit 3 GUI CONFIGURATION This part will show all the main functions for MDVR including SEARCH SETUP and INFORMATION SEARCH is for searching all the regular video files and alarm files SETUP is for all the configurations for MDVR including recording playback event network setup and INFORMATION displays the MDVR and accessory working status 3 1 SEARCH 11 3 1 1 The user can search all the video files including normal files alarm files by record date and file type and storage source Please select the REC SEARCH and enter into following screen REC SEARCH SOURCE HDD sD M ALLE 2013 12 12 SEAR
3. DST MODE MANUALE 2AMON THIRD 2AMON THIRD SUNIN E 2013 12 12 FORMAT DD MWYYYY THU 09 58 06 FORMAT 24H M Timesync vw TIME ZONE 8 ost GR postmon HATO 2AM ON SECOND SUNDAY IN MARCH 2AM ON FIRST SUNDAY IN NOVERMBER Scroll to SAVE to make the setting valid 18 3 2 1 2 OPTIONS OPTIONS ON OFF TYPE TIMER BOOTUP TIME 06 00 00 SHUTDOWN TIME 18 00 00 AUTO BOOT UP ON SCHEDULE OFF M lt BUZZER 922 IDLE TIME 30 300 SEC 300 EVENT FILES AUTO EXPORT USB ON ASPECT 4 3 TRANSPARENCY 25 SAVE EXIT ON OFF TYPE There are ignition timer and ignition or timer three options They are the modes to boot up the MDVR device not for recording For example the setting is TIMER from 5 00 12 00am MDVR will startup automatically at 5 00am and shut down at 12 00am but after the MDVR starts up it records or not depending on the setting in the SCHEDULE and RECORD SETTINGS menu A IGNITION for shut down delay function If the user make the setting for SHOW DOWN DELAY time is 5 min the MDVR will shut down in 5 minutes after the ignition is off This means that for example if the SHUT DOWN DELAY setting is 1 hour It is 5 00am when the user turn off the ignition the MDVR system will shut down at 6 00am not at 5 00am OPTIONS ON OFF TYPE IGNITION SHUTDOWN DELAY 1 24H 23 06 09 BUZZER oldar IDLE TIME 30 300 SEC 300 EVENT
4. FILES AUTO EXPORT USB oN B ASPECT RATIO 4 3 TRANSPARENCY 25 SAVE EXIT B TIMER MDVR will boot up or shut down automatically at certain time configured every day C IGNITION OR TIMER means include both conditions 19 OPTIONS ON OFFTYPE IGNITION OR TIMER BOOTUP TIME 06 00 00 SHUTDOWN TIME 18 00 00 AUTO BOOT UP ON SCHEDULE OFF SHU T DOWN DELAY 1 24 H 23 06 09 BUZZER OFF IDLE TIME 30 300 SEC 300 EVENT FILES AUTO EXPORT USB ASPECT RATIO 4 3 TRANSPARENCY 25 SAVE EXIT BOOT UP TIME The exact time for MDVR starts to work every day SHUT DOWN TIME The exact time for MDVR shut down every day AUTO BOOT UP ON SCHDULE ON means TIMER start up function is linked to record function This means that if the user boot up the MDVR device at certain time and the MDVR system will to start recording at the same time For example if the BOOT UP setting is 6 00 and SHUT DOWN TIME setting is 8 00am but record schedule is 5 00 then the MDVR will start up and record at 5 00 BUZZER SWITCH ON means the buzzer will alarm when alarm happens OFF means no audio when alarm happens IDLE TIME SEC How long the operation interface will switch to the QUAD view If the user does not make any operation on MDVR GUI for some time the MDVR system will return back to the QUAD view automatically We suggest that the user please setup this idle time as the user setup demand Once the MD
5. and X 4 modes available FWD Fast forward the video while playback X2 and X4 mode available No use at present Export all the event record files of the day to USB by press F1 key 2 Reserved for future use 4 PTZ Function Key X3Il MDVR can support PTZ camera by the protocol PALCO D PALCO P While the MDVR is connected the PTZ camera by RS485 signal on the RS232 485 expand box following commands can control PTZ ZOOM IN IZOOM OUT 3 RECALL Recall the position that the user have setup 1 3 GUI GRAPHIC USER INTERFACE TREE JO OPTIONS CONFIG REGISTER INFO SYSTEM LOG SYSTEM FORMAT BLACKBOX FILE UPGRADE GEO FENCING RECORD OSD OVERLAY SUB STREAM CAMERA SETTING SCHEDULE RECORD SETTING OTHER SETTING E 4 Ee SERVER FTP SETTING NETWORK WIFI FTP FOR SNAP MOBILE NETWORK ALARM OUTPUT CAMERA VOLTAGE ACCELERATION EMERGENCY EVENT TEMPERATURE PERIPHERAL SMART BATTERY DIAL STATUS HISTORY MODULES BATTERY INFO 2 SYSTEM START UP After connecting the MDVR to a vehicle power supply turn on the vehicle ignition and the unit will automatically start up Power is normally supplied to the MDVR as long as the vehicle ignition is ON Display only view of the cameras is immediately available to be viewed in quad mode Normally the power supply for MDVR is about 12V 3A without any accessories System Login for Setup NA
6. priority is lowest 3G ACT means the user can define a sensor to active the 3G module as there is an active mode in 3G setup interface they are corresponding options 44 SENSOR TRIGGER ACTION FULL SCREEN 3G AC T FRONT PAGE SAVE 3 2 4 2 SENSOR OUTPUT IQ MDVR supports 2 sensor outputs All alarm types can trigger the two sensor outputs such as sensor1 8 over speed temperature video loss and so on please access the menu GUI gt gt gt gt SETUP gt gt gt EVENT gt gt gt SENSOR OUTPUT as follow Remark Sensor out means when there is an event triggered the corresponding sensor out will give 12V 2A output and the duration is the alarm time the user have setup so the user can associate different sensor to different alarm types SENSOR ALARM OUTPUT ALARM TYPE SENSORI SENSOR2 OFF SENSORI OFF SENSORS OFF SENSORS OFF SENSOR7 OFF gt SENSOR4 OFF 7 P SENSORS OFF GEO FANCING NEXT PAGE SAVE 45 ALARM TYPE OVERSPEED LOW SPEED HIGH TEMP LOW TEMP ACCALERATION VIDEO LOSS MOTION BLIND FRONT PAGE NEXT PAGE SAVE ALARM TYPE LOW VOLTAGE PANIC FRPNT PAGE SAVE EXIT ON means this input can trigger this output OFF means can t 3 2 4 3 SPEED Setup the alarm for over speed and some other parameters SPEED SOURCE GPS VEHICLE SPEEDCHECK SPD 020 PIS 00200 CALIBRATE SPEED UNIT MILEAGE ON OFF MILEAGECALIBRATE 000000 KM C
7. unique and cannot change it 3 2 3 2 SERVER NETWORK The sever IP and port setting for PC software SERVER CENTRER SERVER 1 NET OPTION CABLENET M MESSAGE SERVER 8 M 192 168 000 100 PORT 08080 MEDIA SERVER STATIC IP v 192 168 002 070 PORT 07263 PGDOWN SAVE EXIT 37 CENTRER SERVER 2 NET OPTION WIFINE T MESSAGE SERVER STATIC IP 192 168 000 100 PORT 05556 MEDIASERVER 5 M 192 168 002 070 PORT 10090 PGUP SAVE EXIT There are two center servers the user can setup by the practical application Usually the user need one server for CMS real time monitoring by 3G and ADS to download the video file or Ceiba to check the video by WIFI The user can connect MDVR via WIFI or CABLE and 3G at the same time NET OPTION There are three options The first one is WIFI The second one is cable network and the third one is MOBILE NETWORK Please select the correct option MESSAGE SERVER This server IP must be the IP of the PC that installed message server for PC software connection The user can setup it as Static IP or Dynamic Domain name due to the server PORT please use the default port 5556 here MEDIA SERVER IP AND PORT NO use at present 3 2 3 3 WIFI This menu is used to setup WIFI parameter for Auto download software or Ceiba playback software ENABLE CLIENTEJ GETIP TYPE IP 192 168 003 100 255 255 255 000 GATE 192 168 003 002 ESSID PAS
8. version the battery information not allowed to make the configuration for the MDVR Below is the GUI interface for the user password authority Usually this level can be authorized to the driver REC SEARCH Al EVENT FILES SYSTEM sis 5 DIAL STATUS F gu 814 XL A 2 i HISTOTY 2 MODULES 24 POWER USER PASSWORD the default user password is 66666666 The authorization for this password is to check the video files playback the files and make the setting for the MDVR but not allowed to access below menu FORMAT USER SECURITY SYSTEM LOG SYSTEM RECORD w nettle ET 7 gt UPGRADE 7 NETWORK BLACKBOX FILE mm k GEO FENCING P ADMINISTRATOR The default password is 88888888 This is the highest level of the user which indicates that the user can access all the menus for the MDVR and make all the configurations for the MDVR device Re enter must be same input as first password otherwise the system would not accept the password setting when password does not match between the first line and the re enter line Scroll to SAVE to make the setting valid 3 2 1 7 CONFIG CONFIG DEFAULT SETTINGS DEFAULT RESETALL HISTORY INFO DEFAULT EXPORT CURRENT SETTINGS SAVE AS MDVRCFG CFG TO THE ROOT OF EXTERNAL STORAGE DEVICE EXPORT IMPORT THE MDVRCFG CFG IMPORT FROM THE ROOT OF EXTERNAL STORAGE TOMDVR Restore t
9. ALIBRATE _ OSD ENABLE THRESHOLD LOWSPEED SPOL OFF 4 5 OVERSPEED SPDO ad 001 SOURCE MDVR is capable of capturing vehicle speed via GPS antenna or Vehicle speedometer e Browse between the settings of GPS or speedometer from the list e Please note that the GPS antenna should be connected to MDVR to receive satellite signals for speed 46 For information on capturing speed from speedometer please contact local distributor for more technical support SPD CHECK Speed check is used to calibrate the offset speed when connected to the speedometer That s to say the check only available when speed source is vehicle e Input the first area with the vehicle speed for example at 80 in KM H e Start the vehicle and the second area will show the data from speedometer in HZ e When the vehicle reach to 80 KM H shown in vehicle meter or dash board and keep this speed at 30 seconds then press the Check to make the system calibrate the second area HZ set as first area data 80 SPEED UNIT MPH or KPH MILEAGE is the total mileage that the MDVR has run OVER SPEED If the vehicle exceeds the high speed limit MDVR will trigger the alarm signal when the following option ALARM set as YES until the driver slows down the speed LOW SPEED If the vehicle exceeds the low speed limit MDVR will trigger the alarm signal when the following option ALARM set as YES until the A
10. CH EXIT SOURCE Source means which storage medium the recording files are stored in Hard disk is the main recording medium for MDVR X3ll But this model can support SD card for mirror recording as well TYPE The type of the file including all file alarm file and normal file DATE MDVR system will display the current date automatically The date with record files is indicated by green The date with alarm file is indicated by red The date without video files is indicated by background color Please press SEARCH to enter into the below menu REC SEARCH CHANNEL 14 NONE jg LOCK NORMAL ALARM TIME 00 00 00 05 30 59 11 01 59 CHT CH2 CH4 START TIME 00 00 00 REPLAY UNLOCK END TIME 11 01 59 EXPORT EXIT CHANNEL As X3ll supports 4CH the user have to choose the channels from which channel the user want to playback the video 12 VIDEO FILE STATUS GREY mean there is no video file in this channel or no video during this period GREEN means the file is normal recording file RED means alarm file but not locked means the locked alarm files START TIME and END TIME The MDVR device can support the video clip function This time schedule is for both playback locally playback on MDVR device and export export to thumb drive and playback on PC by MINI Player or Ceiba software The user have to choose the channel first and then setup the start time and end time for the video clip For example i
11. COL PELCO PH PELCO DRY BAUDRATE 240 v 2400 4290 Mo M 8 vE STOPBIT 5 M5 vie M5 M VERIFY NONE M None ADDERESS 001 001 001 001 SAVE CHANNEL The channel of PTZ connected PROTOCOL select the protocol of different PTZ there are two protocols to switch and the default is Pelco D BAUD RATE select the different baud rate for the PTZ there are 1200 2400 4800 and 9600 DATA BIT there are 5 6 7 8 options to select default setting is 8 STOP BIT there are 1and 2 to select the default setting is 1 VERIFY there are None Odd Even Mark Space to select the default setting is none ADDRESS Fill the code of respective PTZ 50 3 2 5 2 SETUP This interface is for external accessory connection such as control pane PTZ Inertia sensor LED screen station announcement and so on MODE Standard mode means connect MDVR standard accessories to the 485 port EXT COM SETUP MODE STANDARD M COM1 CONTROL PANEL ACCELERATION EXT GPS STANDARD 485 3 2 5 3 SMART BATTERY SMART BATTERY CHANGE TOBATTERY VOLTAGE 80 V REMAIN TIME ALARM 300 MIN To protect the battery if the battery voltage is lower than 8 0V or so switch to UPS for power supply automatically And the system will calculate how long the UPS can work Once the time left lt setup value trigger alarm 3 2 5 4 LANGUAGE SETTING Currently the MDVR can sup
12. DATE TIME DATE FORMAT Press ENTRE remote control to select different format MM DD YYYY DD MM YYYY YYYY MM DD TIME FORMAT 12H or 24H Press ENTER to select different format TIME SYNC SOURCE The system can adjust the time in different zone via either GPS or NTP A While selecting the GPS the MDVR device must have GPS connection Should have GPS module and antenna and GPS must receive the signal When the system time arrives the sync time MDVR unit will synchronize with GPS time once 17 While selecting the NTP Network Time Protocol the device must have network access connection and assign the NTP IP location TIME ZONE Please choose the correct time zone for MDVR system SYNC TIME This is the time when the unit will sync the system time every day The method depends on the setting on the TIME SYNC SOURCE option NTP SERVER IP Input the server IP which can support NTP protocol in order to allow the system can have time synchronization through the network Example 192 43 244 18 129 6 15 28 211 22 55 116 194 88 2 60 DST Daylight Time Only when it set on the following option will available DST MODE There are two modes AUTO MANUAL Auto According to the international DST i e valid only between 2AM on Second Sun in March and 2AM on First Sun in NOV 2013 12 12 FORMAT amp THU 09 58 20 FORMAT 24 Timesync lw TIME ZONE 8 DST ON
13. ENT NAME The event name is the one thatthe user setup for the events on the EVENT menu But here just show the event OSD information the abbreviation The alarm includes such as video loss I O sensor alarm for over speed low speed or high temperature and so on DATE Display the date on which the alarm is triggered TIME The start time when the alarm is triggered REC if there is an red R means it has the corresponding alarm video files REV Reversing selection For example If there are no any files are selected and the user select REV all the files are selected If one file is selected and select REV the others will be selected and the originally selected one will be unselected EX LOG Export the selected LOG to external device by USB port on the front of MDVR EXPORT Export the corresponding video if the event has the record file If no related video file the user will got a remind information that no video file 3 2 SETUP Move arrow key to select SYSTEM and press ENTER The MDVR setup screen will show the menu as below 16 DATE TIME OPTIONS Rena REGISTER INFO 2 J FORMAT 1 4 F UPGRADE was E USER SECURITY 1 CONFIG SYSTEM LOG NETWORK BLACKBOX FILE i ar GEO FENCING 3 2 1 SYSTEM 2013 12 12 FORMAT DDIMMYYYY amp THU 09 58 06 FORMAT 24 Timesync WIPE TIME ZONE 8 SYNC TIME 06 30 00 NTP SERVER IP 255 255 255 255 AUTO 3 2 1 1
14. Kbps MAXCHANNELS 4 CAMERA CH1 Ci CH2 CIF CH3 CIF CH4 cir M SUB MODE FIX ADTAP SAVE BAND WIDTH Setup the band width for the sub stream which due to the network bandwidth of the SIM card ENABLE Enable the function RES Resolution 33 FR Frame rate frames per second 1 25 1 30 for NTSC adjustable SUB MODE There are 2 options fixed and adapt Fixed means that the transmitted resolution and frame is fixed by the network width configured Adapt means that the transmitted resolution and frame can be adjust automatically by the network width 3 2 2 6 SCHEDULE SCHEDULE SCHEDULE TYPE SCHEDULE2 EVERY 00 00 00 00 00 0 00 00 00 00 00 00 00 00 00 00 00 00 M 00 00 00 00 00 00 iib 000 00 00 00 0000 00 00 00 00 00 00 5 7777 1 00 00 00 00 00 00 CON 00 00 00 00 00 00 90 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 000 CON 00 00 00 00 00 00 WEEKDAYFROM MON SUN SAVE DATE To select the exact date for MDVR recording Single Day Choose the day to create a recording schedule Every Day Choose Every to apply a schedule to every day of the week Weekday Schedule will only apply Weekdays weekday is from Monday to Friday CSE Choosing the asterisks will suspend the highlighted schedule TYPE Press ENTER to change the type of the recording mod
15. MOBILE DVR USER S MANUAL Ness IQ MDVR Series II User s Manual Rev Oct 2014 REZ E 77 5 1 o Ld CORPORATION 5090 NSW Head Office only www nesscorporation com National Customer Service Centre Ph 1300 551 991 customerservice ness com au All rights reserved No part of this publication may be reproduced transmitted or stored in a retrieval system in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of Ness Ness reserves the right to make changes to features and specifications at any time without prior notification in the interest of ongoing product development and improvement 2014 Ness Corporation Pty Ltd ABN 28 069 984 372 CONTENTS 1 PRODUCTION CHRACTERISTICS AND OVERVIEW 11 PRODUCT OVERVIEW 12 REMOTE CONTROL 1 3 GUI GRAPHIC USER INTERFACE TREE IN SYSTEM START UP IU GUI CONFIGURATION 3 1 SEARCH 3 1 1 REC SEARCH 3 1 2 EVENT FILES 3 2 SETUP 3 2 1 SYSTEM 3 2 1 1 DATE TIME 3 2 1 2 OPTIONS 3 2 1 3 REGISTER INFO 3 2 1 4 FORMAT 3 2 1 5 UPGRADE 3 2 1 6 USER SECURITY 3 2 1 7 CONFIG 3 2 1 8 USERLOG 3 2 1 9 BLACKBOX FILE 3 2 1 10 GEO FENCING 3 2 2 RECORD 3 2 2 1 OPTION 3 2 2 2 OSD OVERLAY 3 2 2 3 CAMERA SETTINGS 3 2 2 4 RECORD SETTING 3 2 2 5 SUB STREAM 3 2 2 6 SCHEDULE 3 2 2 7 OTHER SETTINGS 3 2 5 NETWORK 3 2 3 1 LOCAL 3 2 8 2 SERVER NETWORK 3 2 3 3 WIFI 3 2 3 4 M
16. NGS Bi NS 4 PERIPHERAL 3 2 2 1 OPTION This menu is used to setup the basic parameters for MDVR recording OPTIONS 1 RECORD FILE TIME MIN ALARM DURATION 3 30 SEC 10 2 ALARMPOST 0 1800 SEC 0300 M ALARM TIME SEC 10 M PGDOWN SAVE VIDEO TYPE PAL and NTSC optional The default setting is NTSC RECORD MODE Record mode three modes as following NORMAL When MDVR is power supplied and starts up the MDVR will start to record automatically TIMER This is the switch to start the TIMER recording function When the user enable this switch MDVR will start to record at configured time setting in the SCHEDULE menu EVENT This is the switch to start the event recording Only the user enable this switch when event is trigged MDVR will create event record NORMAL REC RATE normal record rate two option GENERAL MDVR will start to record according to the setup of RECORD SETTING I FRAME MDVR only record by frame the key frame for video in order to take up less space of hard drive BUT when event is trigged MDVR will record according to setup of RECORD menu RECORD FILE TIME MIN Recording file packing size 15 30 45 60 minutes optional 28 ALARM DURATION 3 30 SEC The alarm duration time all the alarm for same type considered to be one alarm during the time configured for alarm duration For example if the setting for alarm duration is 10 sec and during this 10 sec a
17. OBILE NETWORK 3 2 3 5 FTP SETTINGS 11 11 12 15 16 17 17 19 21 21 22 24 25 26 26 27 27 28 30 32 33 33 34 35 36 37 37 38 39 41 3 2 3 6 FTP FOR SNAP 3 2 4 EVENT 3 2 4 1 SENSOR 3 2 4 2 SENSOR OUTPUT 3 2 4 3 SPEED 3 2 4 4 ACCELERATION 3 2 4 5 TEMPERATURE 3 2 4 6 CAMERA 3 2 4 7 VOLTAGE 3 2 4 8 EMERGENCY EVENT 3 2 5 PERIPHERAL 3 2 5 1 PTZ 3 2 5 2 EXT COM SETUP 3 2 5 3 SMART BATTERY 3 2 5 4 LANGUAGE SETTING 3 3 INFORMATION 3 3 1 SYSTEM 3 3 2 DIALSTATUS 3 3 3 HISTORY 3 3 4 MODULES 3 3 5 BATTERY INFO 43 43 44 45 46 47 47 48 49 49 50 50 51 51 51 52 52 53 53 54 55 1 PRODUCT CHARACTERISTICS AND OVERVIEW 1 1 PRODUCT OVERVIEW Ness IQ MDVR4 high end H 264 mobile DVRs Series Il provide the perfect solution for mobile surveillance and remote monitoring Featuring a high speed processor embedded operating system advanced H 264 video compression and decompression GPS location and wireless options MDVR Features and Capabilities Revolutionary vibration resistant technology for 360 degree installation UPS Uninterrupted Power Supply supported to protect the MDVR from the damage of high voltage and provide the power to the MDVR when the MDVR external power is cut off for example in a collision Patented special file system is professional to improve the security level of data provide self recovery function self check self backup for certain critical data and avoid dat
18. R Remark when the user connect MDVR to PC software make sure VEHICLE NO and DEVICE ID is filled Otherwise it can t connect to message server Scrollto SAVE to make the setting valid 3 2 1 4 FORMAT Select the devices to format HDD SD card or external storage device 21 FORMAT DEVICE HDD M FUNCTION FAST FORMAT SLOW FORMAT DEVICE Please press ENTER to select the target device to format There are 3 options HDD USB and MIRROR SD Then press FORMAT to format the device FUNCTION FAST FORMAT SLOW FORMAT FAST FORMAT is the same as the fast format on PC SLOW FORMAT means the MDVR system will check whether the hard disk has bad sectors if so the MDVR will make a record and won t write data here again After format success MDVR unit will restart automatically 3 2 1 5 UPGRADE Upgrade to new firmware or MCU UPGRADE FIRMWARE ONEKEY UPGRADE CURRENT VERSION X15 4 V030003 UPGRADE FIRMWARE Upgrade the firmware MCU Upgrade the MCU HOW TO UPGRADE THE MDVR FIRMWARE 1 Please create one folder named dvrupgrade in root directory in thumb drive and then copy the firmware 22 upgrade file to this folder 2 Insert the thumb drive into the USB port on the front panel of MDVR 3 Please access into the MDVR GUI menu UPGRADE select FIRMWARE option and press UPGRADE MDVR will upgrade the firmware automatically Please make sure the user do not remove
19. SWORDENABLE PWD 8 63 MDVR WIFI be used a CLIENT which means that MDVR system get online by the WIFI module built in MDVR 38 GET IP TYPE There two options STATIC IP means you have to arrange a static IP for WIFI sever and DYNAIC IP means WIFI will get a dynamic IP and make sure the DHCP function is OK IP Enter the static IP address of built in WIFI Only when you select STATIP IP this option is valid SUB Enter the subnet mask Only when you select STATIC IP this option is valid GATE Enter the gateway that the MDVR through to network Only when you select STATIP IP this option is valid ESSID The AP name of this WIFI router PSSWORD ENABLE if the WIFI router need a password please choose the type and input password WEP can only support 5digital ASCII 3 2 3 4 MOBILE NETWORK This interface is to setup the wireless modules type active mode and SIM card parameters when the user connect with net cable please select mode type as NONE MOBILE NE TWORK MODULE TYPE NONE EDGE TD SCDMA NONE M ACTIVE MODE DAIL PARAMETER INTERCOM SETTINGS SAVE EXIT ACTIVE MODE There are three options ALWAYS means when MDVR started up the wireless module will always dial up and connect to message server CALL SMS means only the user call the phone number of the SIM card or send the message to the SIM it will active the wireless module and start to dial up SENSOR mean
20. TWORK WIFI q IN 5 pom WAT S PERIPHERAL FTP FOR SNAP This part will describe how to setup the network parameters for PC software connection RJ45 cable ANIFI connection 3G MDVR can support following PC softare CMS Ceiba ADS CMS Central Management Software is the software to manage the vehicles real time via 3G Ceiba is the playback and analysis software ADS is the downloading software 36 3 2 3 1 LOCAL LOCAL NETWORK 192 168 003 100 255 255 255 000 192 168 003 002 CLIENT PORT 10030 WEB PORT 10090 DNS SERVER 202 096 134 133 MAC ADDRESS 00 18 F5 0A 6B 3D Local IP is the IP setting for the MDVR to make sure that MDVR can go online The user must enter a fixed IP address to use network capabilities please consult with local Internet Service Provider for the information Use NUMERIC keypad to enter the TCP IP address information IP Enter the static IP address SUB Enter the subnet mask GATE Enter the gateway that the MDVR through to network CLIENT PORT no use at present WEB PORT this port is for IE access the user have to add this port when the user want to access to MDVR through IE browser of example the user have to access MDVR by http 192 168 3 155 10090 DNS The DNS of the router when the user want connect MDVR to internet via cable or the CMS server using domain name please setup the DNS server for resolving IP address MAC Address MAC address is
21. VR access into the GUI the MDVR will stop recording EVENT FILES AUTO EXPORT USB When this switch is ON the user can back up all the alarm record files of the current day to thumb drive by press F1 key on remote control ASPECT MODE This is the output mode for monitor TRANSPARENCY Setup the brightness for the screen display as the user want Scroll to SAVE to make the setting valid 20 3 2 1 3 REGISTER INFO REGISTER INFO UNIT S N 00640000CB UNIT ID 00000 99999 00001 COMPANY NAME SVT VEHICLE NO 9999 DRIVER ROUTENAME ABCD DEVICE ID 02009 SAVE UNIT S N The series number for MDVR Each MDVR has only one S N This number is read from special encrypted chipset UNIT ID Device ID Use the NUMERIC keypad on the remote control to enter the system ID from 00000 to 99999 This ID is used to login to the unit if security is enabled COMPANY NAME The name of company Press the arrow key on the remote control and highlight this option and then input the name of the company VEHICLE NO The number of the vehicles DRIVER ROUTE NAME The driver s name and the route name DEVICE ID This is the unique ID can be recognized for the message server of PC software for MDVR including CMS Central Management Software Ceiba Ceiba Playback and Analysis Software and ADS Auto Download Software If the user need to connect MDVR to any PC software please make sure the user setup this ID for MDV
22. VR is 192 168 3 233 the user can log in the MDVR FTP server as follow ftp 192 168 3 233 and the recorded file save path is ftp 192 168 3 233 stm disk 0 p1 2012 11 23 41 Organize v r Favorites Desktop 1 Downloads 1 Recent Places stm File folder Libraries wj Homegroup Computer amp C The default login username is admin password is 88888888 if the user can t login at the first time please try again INTE z 2 6 Rs 2 2 d 3 P i SET D v ppm EU DL INTERCOMSWITCH ON OFF 4 42 3 2 3 6 FTP FOR SNAP FOR SNAP SETTINGS FTP SERVER 255 255 255 255 USER NAME PASSWORD pe SERVER PORE 57755275 SAVE EXIT This page is for uploading snapped image to FTP server when alarm is triggered 3 2 4 EVENT SYSTEM RECORD NETWORK HHIH duc 5 EVENT 57 CAMERA PERIPHERAL VOLTAGE EMERG ENCY ALARM J 5 t 43 3 2 4 1 SENSOR Hi oM COM HIGH COM HIGH oN COM HIGH COM HIGH COM HIGH COM HIGH oN COM HIGH PGDOWN SAVE These are I O sensor functions to detect the drivers behavior such as braking turning left right closing opening the door reversing etc Once these alarms are generated they will be sent to central server by 3G network EN Enable to active this f
23. a fragment that affects system efficiency Dual streams one for local recording and one for wireless transmission 4 channel real time D1 at 25 fps 30fps continuous or priority video recording and live view display Semi transparent GUI makes setting for GUI and live display synchronously Mirror recoding supports the hard disk and SD card recording at the same time with same frame same resolution and same image quality Maximum 1 hour pre recording and 30 minutes post recording Watermark prevents any modification in recorded file which is part of the law enforcement 4 channels for high fidelity digitally recorded synchronized audio matched to 4 video channels User friendly criteria to playback the events associated video only Automatic timer to resume the live display if the unit is idle for user defined time User selectable settings for quality and audio record enable disable for each video channel 12v power supply for multiple devices such as cameras sensors relays and any other accessories Remote Connection Capabilities PC Based Client software for live viewing playback video playback events associated video and download capabilities Support CMS Central Management System for remote monitoring via built in 3G module HSPA or EVDO Ceiba Playback Analysis Software for video playback meta data analysis ADS by WIFI to download the video files and event files 1 2 REMOTE CONTROL Numeric Input Keys Use the numeric butt
24. annel to display the image in the monitor output ROUND Means channel loop function sequence if the user setup time as 5 second which means the video screen will shift to different channel the sequence is from channel 1 to channel 4 in every 5 seconds IP INTERCOM This is the switch for intercom function we also say 2 way audio which means that that driver can talk with centre server directly via wireless network 3G When this switch is ON the audio of intercom will be recorded into channel 4 LIVE AUDIO enable or disable the live audio settings switch 32 3 2 2 4 RECORD SETTING Make the configurations for resolution frame rate image quality parameter setting for each channel RECORD SETTING CAMERA RES FR CH1 CIF 25 CH p 35 HD1 25 CIF 25 SAVE RES Resolution D1 HD1 CIF optional NTSC 704 x 576 01 704 X288 HD1 352 288 CIF PAL 704 x 480 01 704 X 240 HD1 352 x 240 PAL FR Frame rate frames per second 1 25 or 1 30 for NTSC can be adjustable QUANLITY Image quality 8 levels optional Level 1 is the best Normal quality is the quality for normal record and alarm quality is for alarm record 3 2 2 9 SUB STREAM Sub stream is the settings for 3G wireless transmission The user can setup the bandwidth and enable the channels Otherwise the MDVR system can t transmit the live video to the center server The setup interface as follow BANDWIDTH 1000 20 4096
25. as following By Mini player Pe Rb e k E im m gii Um ru ig s inm nu i mg Se P Uu I a S a ia L a mis mi Em MINI player is very simple player allowing the user to easily playback and view files including video audio GPS location alarm information 14 By Ceiba software 3 1 2 EVENT FILES Search for all the event LOG EVENT SEARCH 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 EVENTTYPE ALLFILE B DATE 2013 12 09 SEARCH EXIT EVENT The type of the alarm file including I amp O ALARM ACCELERATION SPPED TEMP ALARM BD ALARM MD ALARM VL ALARM The user can please select different alarm type to search the log and playback the corresponding video files DATE MDVR system will display the current date automatically Or the user can input the date the userrself by the soft keyboard Please press SEARCH to enter into the next menu listing out all the LOG depends on FILE TYPE and DATE selected 15 EVENTLIST SEL TYPE NAME DATE TIME X A MD 2013 12 16 16 21 46 x MD 2013 12 4A6 16 21 21 EXPORT EXIT SEL For selecting the LOG for backup Please move the arrow key on remote control to select the LOG file that need to back up The file selected will be remarked by the icon X Please press REV to for reversing selection EV
26. dmin password is entered to acknowledge the alarm 3 2 44 ACCELERATION There are 3 values for G force inertial sensor X Y and Z X indicates forward and backward Y indicates left and right and Z indicated up and down Threshold is the limitation for the value if the value large than the setting in the menu then MDVR will trigger alarm ACCELERATION ENABL THRESHOLG ALARM LOCK X 45 6 OVERSHOCK SHK ON Y 15 ON B OFF z 55 G X 01 356 Y 01 042 Z 01 106 CALIBRATE SAVE EXIT Ay This function only can be active when the MDVR connected with inertial sensor 3 2 4 5 TEMPERATURE Inspection for temperature 47 TEMPERATURE TEMPERATURE UNIT rcm ALARM SETTING OSD ENABLE THRESHOLD ALARM LOCK HIGH TEMP HT aa or OFF LT E If the MDVR working temperature is higher than the setting for HIGH TEMP MDVR will trigger alarm If the MDVR working temperature is lower than the setting for LOW TEMP MDVR trigger will alarm 3 2 4 6 CAMERA Display the alarm information from camera MOTION DETECT SETTING _ rr CHID MD SENSITIVE M D AREA 8D SENSITIVE 1 SETUP d ALARM SETTING ENABLE ALARM LOCK i OFF OFF B MOTION or E M N VIDEOLOSS OFF OFF SAVE EXIT There are three statuses for camera alarm blind detect motion detect and video loss CH ID please choose the chan
27. e SCHEDULE 1 2 Press the RIGHT ARROW key to enter values using the NUMERIC keypad into any time field SCHEDULE 1 is the first of two possible ON OFF cycles that apply to any day in the period chosen under Date SCHEDULE 2 is the second cycle for any day in the period There is no need to overlap times of SCHEDULE 1 and SCHEDULE 2 Ending at 23 59 of one day and beginning with 00 00 of the next day will provide continuous recording without interruption factory default setting 34 3 2 2 OTHER SETTINGS OTHER SETTINGS INITIALIZE INTERFACE CP3 MENU WATERMARK EXPORT MINIPLAYER IMPORT TTS FILE INITIALIZE INTERFACE This means after MDVR starts up which default interface the user prefer to show CP3 menu interface or quad image interface Quad Image is for the regular monitor output display CP3 Control Panel can support one LCD to display the image and realize the station announcement function the precondition is the MDVR device can support the station announcement function either Quad Image Interface CP3 Interface 35 SPO SPO MENU EXIT WATERMARK Water mark is used to protect original data from illegal modification as long as the user setup water mark EXPORT MINIPLAYER This option is for user to export Miniplayer IMPORT TTS FILE This option is for user to import TTS file for the audio announcer 3 2 3 NETWORK SYSTEM RECORD SERVER Sen NE
28. ecord the date time channel name and vehicle NO into the record files To get the main information for MDVR working easier on QUAD view the user can please just press ENTER on remote control to show below screen This screen will show all the important working information for the MDVR including sensor 3G GPS WIFI signal and connection firmware version MCU version SIM dialed up status etc But the precondition for this OSD is the user must setup the OSD overlay menu to select which information the user want to display 31 05 27 2012 17 30 29 ALARM GPSRACQUIRING SIGNAL DIRECTION 0 4 oY 5 VOLTAGE 11 800 FIRMWARE X8L 4 Tc82331 JIGNITION P d pus pl ma B4F 5 pur s SERVER DIAL UP UNCONNEC TED 2G 0 3G 0 CENTER SERVER 1 NET STATUSTUNCONNECJED CENTER SERVER 2 STATUS UNCONNECTED IMSI mmt 1 1 357789045 07 3 2 2 3 CAMERA SETTINGS To setup the parameters for camera related with each channel CAMERA ENABLE NAME AUDIO a oF or CH2 oF or CH3 oF amp Nu OFF OFF o B ROUND OFF ROUNDTIME 010 5 300 SEC IPINTERCOM LIVEAUDIO ON SAVE EXIT ENABLE Enable the record function NAME The name of the channel For example if the user setup the name for CH1 is ABC the user can see ABC three letters display on the video from channel 1 AUDIO Active the audio record function LIVE to enable the ch
29. f the user select the start time is 01 20 00 and the end time is 02 20 00 then click REPLAY the MDVR system will playback local playback the video file in this period on this channel During playback the user can press ENTRE key to show OSD information UNLOCK the user have to select the channel first and then unlock the files in certain period The user can export the MDVR video files to external storage device for playback easily Just please input the START TIME and END TIME for the video from certain channel for local playback insert the external storage device by USB port and then click EXPORT the following screen will pop up During backing up the external device is not allowed to be moved REC SEARCH CHANNEL 14 NONE LOCK NORMAL ALARM INFORMATION PROGRESS TOTAL 5 NO 1 BACKING DO NOT REMOVE THE USB STARTTIME 00 00 00 REPLAY END TIME 11 01 59 EXPORT TOTAL total quantity of the files that the user selected for back up NO The file number which is being copied to external thumb drive After successful backup the following screen will pop up 13 RECORD SEARCH CHANNEL 1 4 NONE LOCK NORMAL ALARM INFORMATION TIME 00 00 CH1 CH2 BACKUP SUCCESSFULLY CH3 OK CH4 START TIME 00 00 00 PLAY UNLOCK END TIME 11 01 59 EXPORT EXIT After backup the user can copy the video clips to the computer for playback This exported video file can be playback easily by MINI player or Ceiba
30. he default setting and export and import the MDVR configuration EXPORT Export the all configuration for the MDVR to another MDVR to make sure that two MDVRs have the same setting Please insert the external storage device to the USB port and then press EXPORT 25 Then the configuration file will backup to external device RESET Reset all the history info to default values IMPORT Follows the operation EXPORT Import the MDVR configuration file to the MDVR except MAC address and IP Please insert the external storage device to the USB port on the MDVR Must have configuration file in the storage device and then press IMPORT The configuration will be imported to another MDVR automatically RESTORE Restore all the settings to factory default settings 3 2 1 8 USER LOG The user can export or delete the user log in this interface as follow picture Remark The user log mainly include start recording and end recording time event time GPS module status power on and power off time and so on SYSTEM LOG EXPORT SYSTEMLOG DELETE SYSTEM LOG INFORMATION DELETE SYSTEM LOG SUCCESSFUI SURE EXPORT SYSTEMLOG The user log exported to thumb drive is stored by txt format and it will be saved to userlog O0000 0 folder according to the date SYSTEMLOG EXPORT SYSTEMLOG DELETE SYSTEM LOG INFORMATION SYSTEM LOG EXPORTEDSUCCESSFULLY SURE 3 2 1 9 BLACKBOX FILE This function is used to exp
31. locked files cannot be deleted by the HDD SD overwrite function in the retention days When the retention day is expired the locked files will be unlocked automatically and deleted Locked recording file save time can be configured to be 7 10 15 20 30 45 days During the retention time the locked recording files won t be deleted Once pass lock time the recording file LOCK identifier will be from L to U and then can be deleted automatically by overwrite function PRE RECORDED SWITCH ON OFF ON means open the function of pre recording OFF means not If the user need to setup pre recording function the user must open this switch and also setup the time for pre recording in this menu as well 29 ALARM PRE REC TIME 1 60 MIN Pre record time setting is from 1 to 60 minutes For example If the setting for pre record is 30min when alarm is triggered at 10 30 then the record file starting from 10 00 to 10 30 will be packed as one alarm file HDD SD OVERWRITE There 2 options for the INTERNALand EXTERNAL INTERNAL is used for the internal mirror recording SD card If the MDVR connects external fireproof box for mirror recording then the user should select EXTERNAL option Mirror recording means that the hard disk and SD card record at the same time with same frame same resolution same image quality The main purpose for mirror recording is when the hard disk is broken like accident happens the user can still get the vide
32. nel the user want to setup for motion detect and blind detect SENSITIVE this is the detect sensitivity 1 is the most sensitive M D AREA this option is for user to setup the detect area as follow blank square means the area is selected please exits to the setup interface to save the settings 48 3 2 4 7 VOLTAGE LOW VOLTAGE PROTECTION ENABLE VOLTAGE VOLTAGE OF START NTERVAL TIME FOR CMS SHUT DOWN DELAY SAVE CANCEL VOLTAGE PROTECTION means when MDVR system detect that the voltage input always in a low status MDVR will disconnect to CMS and shutdown automatically ENABLE setup the voltage protection switch ON means enable OFF means disable VOLTAGE setup the low voltage limited value VOLTAGE OF START this means when the voltages of the battery reach this value MDVR will startup automatically INTERVAL TIME FOR CMS means when MDVR in low voltage for so long time device will disconnect to CMS server SHUTDOWN DELAY means when MDVR in low voltage for so long time device will shutdown automatically 3 2 4 8 EMERGENCY EVENT To setup the panic button alarm EMERGENCY EVENT CONFIG OF PANIC BUTTON NAME EN ALARM LOCK PB SAVE EXIT 49 3 2 5 PERIPHERAL SYSTEM RECORD i H 1 3 r NETWORK i PERIPHERAL SETUP SMART BATTERY _ EXT COM SETUP 3 2 5 1 PTZ PTZ SETUP CHANNEL CH1 CH2 CH3 CH4 PROTO
33. nther same type like panic button alarm triggered MDVR system will consider them to be one alarm event And the alarm start time will be reset based on the second time for alarm ALARM POST REC 30 1800 SEC Alarm post recording time BUZZER TIME buzzer duration time setup when alarm is triggered OPTIONS 2 HDD SD OVERWRITE LOCKED FILE RETENTION DAY 10 PRE RECORDING SWITCH oN B ALARMPRE REC TIME 1 60 MIN HDD SD OVERWRITE INTERNAL M MIRROR REC TO SD CARD sUB PGUP SAVE MEDADATA CAPTURE The MDVR system will capture the black box file if the user enable this function If the metadata is captured when the user playback the video files the blackbox information will be analyzed as well HDD SD OVER WRITE To make the HDD or SD card overwrite when there is only 8GB for hard disk or 1G for SD card spare space left ON when hard drive space is less than 8G according to First in first out rule the MDVR system will start to delete the earliest record files till hard disk space equal or over 15G except the alarm file which in locked time OFF Device will stop recording when hard drive space is full less than 500M the user must replace a hard disk or delete recording file manually Otherwise the MDVR system will stop recording LOCKED FILE RETENTION DAY For the MDVR video files the user can lock or unlock them Lock function is only for the event alarm files as they are very important The
34. o files in the last minute from the SD card MDVR can provide 2 kinds of mirror recording internal and external Internal means that we have the SD card slot inside of MDVR device and the user just need to insert the SD card in the slot on the MDVR device and ENABLE the switch for mirror recording on the MDVR GUI menu External symbolize that the user need to buy the fireproof box SD card inside in case the vehicle is on fire This fireproof box is specially design for the vehicle accident like fire and the maximum temperature can be 500 Celsus degree can last 15 minutes MIRROR REC TO SD CARD The enable switch for mirror recording 3 2 2 2 OSD OVERLAY OSD OVERLAY DATE TIME ALARM ACCEL DATA TEMPERATURE FIRMWARE VER GPS INFO CH NAME VEHICLE NO 30 OSD OVERLAY rue PREVIOUS DATE TIME Display date and time on OSD POSITION Setup the display position for DATE TIME ALARM Display alarm information on OSD including the I O sensor speed temperature motion detection etc ACCELERATION Display the information for inertial sensor TEMPERATURE Display the temperature on OSD FIRMWARE VERSION Display the current firmware version GPS Display the GPS information fixed means it will display the information always just like date time CHANNEL NAME Display the channel name VEHICLE NO Display the vehicle NO SPEED Display the speed on OSD RECORD is ON means it will r
35. on to input digital in setup menu or switch the full screen for each channel or the channels QUAD view e Navigation rn Arrows AUTO PRESET RECALL ERLISH B B Use the ARROW keys to move between Fi y selections input fields and icons e e Press ENTER to select And EXIT to return and entering into the OSD screen to check the MDVR working status Next and previous is also used to increase or decrease volume when at live or search screens Each MDVR includes remote control that allows the user to transmit commands to recording module and display on screen control menu Remote Control Key Functions 1 Numeric Keypad 0 9 keys During setup number keys are used to input number values In QUAD view the user can press 1 2 3 and 4 to switch the full screen for each channel and press 0 to switch to quad view During full screen view of each camera the user can press 2 amp key to adjust contrast luminance color and saturation and then press and to make the adjustments Pressing 59 will navigate through the color adjustment options 2 Setup Menu Navigation V Up down directional keys Move selection up and down in setup menu gt 4 Left Right directional keys Move cursor left or right in setup menu ENTER key During setup select and save the settings 3 Other Keys Function The user can press LOGIN LOCK or SETUP key to enter the GUI to setup If LOGIN LOCK pas
36. ort the black box file for analysis Please insert the thumb drive to the MDVR and then the MDVR system will export the black box files to the thumb driver directly 26 BLACKBOX FILE BLOCKBOX FILE 3 2 1 10 GEO FENCING GEO FENCING GEO FENCING SWITCH ON EXPORT THE GEO ENCING CONFIG FILE IMPORT THE GEO ENCING CONFIG FILE GEO FENCING SWITCH this is the switch to enable GEO Fencing function This switch is only for MDVR terminal To finish the setting for GEO FENSE the user need to setup the CMS software as well For more details please refer to the manual for CMS EXPORT and IMPORT The function can be used in WCMS only not standard CMS from Ness The user can setup the GEO fencing in the WCMS side and this configuration file will be sent to the MDVR system by wireless network The user can EXPORT this configuration file to the thumb driver and IMPORT this file to another MDVR system Remark Geo fencing means the user can setup a special virtual area for the vehicle when the vehicle enters into or out of this area the MDVR system will trigger the alarm For more details please check the CMS manual 3 2 2 RECORD Setup the related configuration for record 27 ES o amp G 7 1 OSD OVERLAY lcu NE CAMERA SETTINGS SYSTEM RECORD RECORD SETTINGS 1 S 1 SUB STREAM 2 SCHEDULE S NETWORK best nett u a MES OTHER SETTI
37. port 4 different languages English Russian Spanish and Portuguese Please setup the system language here 51 LANGUAGE SWITCH CHOOSE LANGUAGE ENGLISH RUSSIAN SPANISH POR TUGUESE 3 3 INFORMATION HISTOTY MODULES Be BATTERY INFO 3 3 1 SYSTEM Display the MCU version firmware version HDD status and SD card information 1 NO HDD means No HDD installed or the HDD is defective and cannot work 2 NO FORMAT means HDD installed but not formatted All the new hard disk must be formatted after installation 3 showing the detailed information for HDD means HDD works fine 52 SYSTEM INFO FIRMWARE VERSION X15 4 V030003 MCU VERSION X1 M06 S TM8S T309241 SD HDD INFORMATION DEVIE CAPACITY FREE RECORD SPACE TIME HR MIRROR SD Capacity This is the capacity for the hard disk recording after format Free Space the spare space for hard disk for recording Record capacity The time means that how long that the hard disk can recording based on the current configuration of the MDVR like image quality resolution frame rate with the free space 3 3 2 DIAL STATUS The data for dial status information DIAL STATUS MANUFACTURER MODULE MODULE NAME HSPAUSAMODEM SOFTWARE VERSION LWA0021 1 2_ MG37 HARDWARE VERSION SERVICE NOSERVICE ROAM DIALSTATUS DIAL NUM CONNECT TIME SEND DATA RECEIVEDATA 3 3 3 HISTORY The data for history information
38. s the user can setup one sensor to active the wireless module only when the user triggered the sensor the wireless module will start to dial up and then connect to internet 39 ACTIVE MODE ACTIVEMODE ALWAYS CALL SMS SENSOR M SAVE EXIT DIAL PARAMETER settings for SIM card please check the setup as follow form DIAL PARAME TER USER NAME PASSWORD ACCESS NUMBER SAVE EXIT Network Type Username Password Access number CDMA card card 777 EVDO card card 777 WCDMA Please check the APN with SIM card manufacture 99 GPRS card card Please check the APN with SIM card manufacture 99 1 EDGE card card Please check the APN with SIM card manufacture 99 1 TD SCDMA card card Please check the APN with SIM card manufacture 98 1 INTERCOM SETTINGS it s a switch for interphone function which can realize speak to center via SIM card 40 INTERCOM SETTING INTERCOMSWITCH 4 SAVE 3 2 3 5 FTP SETTINGS The MDVR be used as a FTP server This means that the user can login IE by the MDVR IP address to check the MDVR equipment video files in the hard disk and download the video file This interface is to setup the name and password to control the server limit Standard FTP protocol but not all functions are valid for example delete or create file folder is invalid FTP SETTING PASSWORDENABLE ON OFF M USER NAME PASSWORD SAVE EXIT If the local IP of MD
39. sword is enabled the user have to input default admin password 88888888 To reset the MDVR to sleep mode The user can press power button again to let MDVR start up when it is in sleep mode LN Switch full screen of one channel to quad view Brightness contrast color adjustment for each channel Use button to change the values The user have to adjust the values for each channel individually SETUP Login GUI to setup the parameters EXIT Return to the previous menu STOP Used to stop the recording manually Only valid when the user setup the record mode by the setting in MDVR menu RECORD Used to start the recording manually Only valid when the user setup the record mode by the setting in MDVR menu Freezes playback to a single frame and can advance one frame at a time To PAUSE STEP advance the frame press Pause Step to move frame by frame Press EXIT to return to normal playback speed PLAY Starts Resumes playback from any other mode FF RR Frame by Frame etc SLOW Reduces playback speed to 1 2 1 4 1 8 modes Press PLAY to return to normal P playback speed Quick search mode when the user playback the record file in MDVR Press GOTO 3 button and input the desired time and the select SURE to jump to the specific time the user want to playback 1 Increase volume while playback if audio is recorded PREV Decrease volume while playback if audio is recorded Rewinds the video while playback X2
40. the thumb driver or cut of the power for the MDVR during upgrading the firmware as this is very easily to damage the FLASH for MDVR 4 During the firmware upgrade then following screen will pop up System Updating 5 After upgrade successfully the MDVR system will restart automatically as follow System Initializing Please check the firmware version after the MDVR reboot up and make sure that the firmware upgrade is completely successful MCU UPGRADE The step is the same as upgrade firmware Ifthe FLASH is damaged or firmware crashes The MDVR can boot up to System Initializing interface L only and the POWER LED on the MDVR is ON It cannot boot up to quad view interface For this situation please contact Ness technical support if trying to upgrade the firmware by TFTP upgrade 23 3 2 1 6 USER SECURITY Setup the password for user and admin USER SECURITY PASSWORDENABLE on H SELECT USER ADMINISTRATOR POWER USER USER M PASSWORD RE ENTER SAVE PASSWORD ENABLE active password access Selecting ON will require a password in order to access the setup menu There are 3 levels for MDVR setup the USER the POWER USER and ADMINISTRATOR USER PASSWORD the default user password is 22222222 This user level is used for the common user who can check the video files and playback the file and system information only e g network status the MDVR firmware
41. unction NAME Press ENTER on the Name field to display the soft keyboard Enter the text name to identify the source of each sensor connected to the unit OSD Input the numbers and characters they will be embedded into the alarm video files when alarms happen and it will also display in live view Please press Enter into the soft keyboard The label also identifies the type of event when doing a quick search using EVENT SEARCH option SET LOW normal close means the power level is from high to low to trigger the alarm HIGH normal open means the power level is from low to high trigger the alarm ALARM Press ENTER to select between OFF or ON ON means when sensor triggered alarm LED will flash OSD will display in the live view a red A will display in each channel until re login the system with account the flashing will disappear also MDVR will record the event log and if the security set as OFF when the user trigger the sensor there is no alarm LED flashing and MDVR won t record the event log LOCK To enable the event does not erase during the over write process of hard disk NEXT PAGE Sensor trigger action means setup the alarm linkage for each sensor for example the user setup the image of channel 1 as the alarm linkage for sensor1 when the alarm from sensor is triggered the image from channel 1 will change to be full screen And the priority is from sensor 1 to sensor 8 Sensor1 priority is highest Sensor 8
Download Pdf Manuals
Related Search
Related Contents
Sony VAIO VGN-AR71MR User Guide Manual Computer Gear 24-1521 headphone ficha tecnica crema catalalana www.trevi.it "user manual" scrubbing bubbles® gel nettoyant pour cuvette 第165回 衆議院 経済産業委員会 平成18年11月7日 第4号|国会会議 empfang - TA Triumph Kenmore 4.5 cu. ft. Slide-In Gas Range - Stainless Steel Owner's Manual (Espanol) Copyright © All rights reserved.