Home

USER MANUAL WEIGHT INDICATOR

image

Contents

1. display the alphanumerical and function keyboard allow the operator an easy and immediate use and provide the microcontroller with DATA ENTRY functions in addition to the normal weighing functions The input output allows the instrument to control various external devices to receive external commands control a printer and communicate with a personal computer or to be inserted in a network of weight indicators controlled by a PC ZN warno Please note that this instrument is covered by a warranty and MUST NOT BE OPENED BY THE USER for any reason whatsoever Any attempt to repair or modify the unit exposes the user to the risk of electric shock and will invalidate the entire warranty If any problems are found in the unit or with the system in which it is used the fact must be communicated to the manufacturer or the dealer from whom it was purchased In any case DISCONNECT THE POWER SUPPLY before taking any action The version with the 6V rechargeable battery has to be completely recharged 12 hours in the first installation of the instrument we RECOMMEND disconnecting the battery if the instrument is not going to be used for more than 30 days In order to avoid the deterioration of the rechargeable battery In standard conditions never leave the battery partially or completely uncharged at least once a week recharge it completely In case the instrument is not used for a long period one needs to 1 completely recharge th
2. M dup EAM d e 42 13 2 9 EO TAEIZATION TOLERANCE HELD nu ete bn utr unus 42 19 20 CONDITIONS FOR TOTALISATION SSeS mess 42 13 2 7 PRINT REENABLING AND ttiv bett vont ile bw t eth a Ue bei ibo RE ach aan 42 13 2 8 VISUALISATION AND CLEARING OF THE ACCUMULATED TOTALS nne 43 13 2 9 CLEARING AND AUTOMATIC PRINTING OF THE PARTIAL TOTAL AFTER N WEIGHS 43 19 2 TO etiim PP 43 13 2 101 ADDITONAL VALUE scenes SSS Sea 43 192 10 2 PROGRESSIVE DIGIS cencia ae 43 S210 ANCE tO ORE SOIC ER C RU 44 USA EOM iS Ciz em 44 14 PRINTOUTS O niae uta Suk a en P ST 44 14 1 LINKING OF THE FORMATS TO THE PRINT FUNCTIONS 45 14 1 1 QUICK LINKING OF THE FORMATS Int EIOS 46 14 2 FORMATTING READING PRINTOUT bert Fri veda ttal Spa ava Heu o tua oco ut n Ea eec 47 143 REPETITION OE THE LAS EXECUTED PRINTOUTS SN SSRIS SRS 47 3 3590EKR 3590EXP 3590EXT CPWE CPWET series indicator E AF02 02 12 05 EN U 14 4 STANDARD PRINTING 5 47 15 OTHER dg egets 9 4T NONIS NIS C EUER 4T 15 2 DISPLAY OF NET WEIGHT WITH SENSITIVITY X 10 for testing use during calibration 48 1
3. 4 1 6 1 19 KEY INFRARED REMOTE CONTROL With this type of remote control the functioning of the keys will be as described in the following table FUNCTION OF THE KEYS FA F3 F1 F3keys NUMERIC KEYS Entry of digits TARE function or increase of a digit while entering a KEYBOARD KEY OR FUNCTION EMULATED F C ZERO Decrease of a digit while entering a value MODE scrolls the digits to the right while entering a value PRINT Confirms the entered value or enters the displayed step HELP key ZERO 3590EKR 3590EXP 3590 CPWE CPWET series indicator E AF02 02 12 05 EN U 4 1 6 2 6 KEY RADIO REMOTE CONTROL With this type of remote control the functioning of each key can be programmed so that it is matched to one of the available keys of the indicator This configuration must be carried out in the Setup environment in the lt lt inF Red gt gt step TECH MAN REF after the selection of this type of remote control By pressing the HELP key of the indicator it s possible to see while weighing the list of the functions matched to the keys of the indicator and also to the keys of the remote control see section 4 1 4 EXAMPLE OF CONFIGURATION USE OF MORE REMOTE CONTROLS WITH ONLY ONE INDICATOR If one works with only an indicator it is possible to use any 6 key remote control without combining it to the indicator therefore without limiting the number of
4. WWW esems SSS o ECNLUTIIT NN O SYMBOLS FUNCTIONS ON THE LCD DISPLAY SYMBOL FUNCTION The weight detected by the weighing system is near the zero included within the interval of 1 4 and 1 4 of the scale division The weight is unstable The displayed weight is a GROSS WEIGHT depending on the software language The displayed weight is a NET WEIGHT A tare value has been acquired T manual tare value has been entered t kx s Lb US mT in use ton ki lili ill Unit of measure in use ton kilogram gram pounds millilitres or millivolts 1 Me Active weighing range see section 8 Active scale see section 5 22 3590EKR 3590EXP 3590EXT CPWE CPWET series indicator E AF02 02 12 05 EN U Indicates that a specific function of the instrument is active Battery charge level see section 4 2 2 otatus output respectively non active and active Icon viewable only with active DIAGNOSTICS PERIPHERAL UNITS function see section 15 5 otatus input respectively non active and active Icon viewable only with active DIAGNOSTICS PERIPHERAL UNITS function see section 15 5 Serial communication status with external device Icon viewable only with active DIAGNOSTICS PERIPHERAL UNITS function see section 15 5 Active during the configuration of the date and time Locked keyboard see section 4 1 3 In the HELP menu these respectively indicate whether a key is unlocked or locked in
5. c Take away the reference quantity from the container and press TARE d The display will show in negative the PIECES which have been extracted and with each following extraction the total of the extracted PIECES 13 1 6 COUNTING OF THE REMNANT a Load onto the platform the full container and press TARE to undertake its weight value as a tare b With F7 select a reference quantity c Extract the reference quantity from the container and press TARE d Enter manually or recall from the tare database the already known tare value see section 7 e The display will show the pieces left in the container NOTE it s possible to totalise the pieces shown as negative by enabling the totalisation in discharge see section 13 2 1 13 1 7 COUNTING WITH THE USE OF THE DATABASE If a certain number of articles has been memorised as shown in section 11 1 it is possible to recall the specific article and If present use the linked A P W in order to count without executing the reference operation a Load the container and press TARE b Select the article from the database c Putthe quantity which will be shown on the display 13 1 8 COUNTING WITH 2 OR MORE CONNECTED SCALES The selection of the scale on which one intends to work takes place by pressing the 2nd F key and then the 1 2 3 4 numerical keys The display shows e The NET WEIGHT on the first line or GROSS WEIGHT if a TARE value has been entered the calculated A P W if t
6. 200 000 9 WEIGH 00000000 Total article weighs or weighs general total E WEIGH 00000000 WEIGH 00000000 Total quantity of pieces or article total weigs if a reference has not been executed First customer description CUSTOMER TEST Active scale and active semiautomatic tare if qTq98 manual tare ri 9 8 B1TARE 0 000kg Active scale and 1 tare value if manual tare JS 798 B1 1 T 0 000kg B1 1 T 0 000kg Furthermore by linking the number of a specific visualization to the function preamble function in the lt lt F KEYS gt gt step it is possible to select it directly with a direct key for example F1 key to select the visualization n 1 and F2 key to select the visualization n 2 NOTES Default Visualisation 0 If the EEEEE message appears this means that the value exceeds the maximum number of digits shown by the instrument CUSTOMIZED VISUALISATION Through the function 120 matched by default to the keys combination Fn F9 one can enable the data visualisation programmed in the print format 99 or change the visualized data if the function is already enabled For the programming see the manual of DiniTools software 27 3590EKR 3590EXP 3590EXT CPWE CPWET series indicator E AF02 02 12 05 EN U 9 SCALE SELECTION If various scales are connected in order to select these press the 2ndF key and then a numeric key from 010 4 0 gt gt Scale con
7. The weight is 9 divisions above the Maximum Capacity Approved instrument the weight is under the gross zero 100 divisions OR OUT CAPACITY UNDERLOAD Approved instrument The weight is under the gross zero 100 divisions Non approved instrument The weight is under the gross zero capacity 9 divisions SAMPLE Error In the sampling phase the accuracy assigned to the APW through the uM PMu udi and dEC PMu parameters in the F MoDE TECH MAN REF is not sufficient for sampling insufficient number of decimals and APW unit of measure In the sampling phase the Weight shows to be less than the reference limits configured in the F MoDE gt gt Count step TECH MAN REF SAMPLE ERR DIV In the sampling phase an APW is less than the acceptable minimum value 2 ae internal divisions SAMPLE ERR TIM Error timeout in the sampling phase when the weigh are instable or out capacity for 10 second SAMPLE APW optimisation see section 13 1 3 Execution of scale zero see section 6 ZERO TARE Tare execution see section 7 CLEAR Tare cancellation see section 7 4 3 Turning on printer for maintenance see section 3 4 GROSS Visualisation of the gross weight Visualisation of the net weight Tare lock or enabled keyboard function Tare lock or disabled keyboard function ENTER RETRY Error during printing press ENTER to restore the printing or C to cancel it and C CAN
8. 0 to 131071 it indicates the weigh number in the current rewriting of the alibi memory With each storage the weigh number is increased of 000001 when this reaches the value 131071 it restarts from 000000 and the rewriting number increases of 00001 If the weigh can not be saved in the alibi the numeric ID will be substituted with the message NO For example If the weigh which has been stored is the following PIDST 1 1 000kg 1 000kg 00126 131071 the following will be PIDST 1 1 000kg 1 000kg 00127 000000 NOTE possible to read the last 131071 weighs 52 3590EKR 3590EXP 3590 CPWE CPWET series indicator E AF02 02 12 05 EN U 16 1 READING OF THE WEIGHS CARRIED OUT Through function 425 combinable with the desired key F KEYS step TECH MAN REF it s possible to read a carried out weigh first enter the rewriting number of the Alibi memory rEW id confirm with ENTER and then enter the weigh number id and press ENTER The ID is accepted only if valid If the alibi memory is empty the message EMPTY appears on the display for a few instants if the ID code entered is not valid the no id message appears for a few instants and then one exits the step By entering a valid ID code the display shows the following data selectable through the arrow keys 4 Ch X in which X is the selected channel number from 0 to 4 Gross weight value with unit of measure Tare weight value with unit
9. 13 2 1 1 and 13 2 1 2 13 2 2 TOTALISATION WITH AUTOMATIC EXECUTION OF THE TARE It is useful for formulation or dosage applications and allows to automatically tare after the accumulation of the weight on the scale both in loading as well as in unloading and manually as well as automatically allowing to totalise the subsequent one on its own and without unloading the scale see also section 7 10 13 2 3 MANUAL OR AUTOMATIC TOTALIZATION The operation of accumulation normally done manually with key F6 can be done automatically when the weight is stable The choice of the totalisation execution mode is made in the F ModE gt gt totAL gt gt EXE tot AUTO MANUAL TOTALISER parameter TECH MAN REF 4 3590EKR 3590EXP 3590EXT CPWE CPWET series indicator E AF02 02 12 05 EN U 13 2 4 TOTALISATION DELAY Only with the automatic totalisation is it possible to set a delay for acquiring the weigh this delay period runs from the weight acquisition and the totalisation oee the F ModE gt gt totAL gt gt dLY tot step in the technical manual TECH MAN REF 13 2 5 TOTALIZATION TOLERANCE FIELD It is possible to define weight interval between 0 and the scale capacity inside of which it is possible to carry out a totalisation and outside of which the totalization is not accepted Use of the totalling field is particularly useful when totalling is done automatically with the weight stable SETTING THE TOTALISATION THRESHOLDS e
10. Through the 500 function combinable with the desired key lt lt F KEYS gt gt step TECH MAN REF it s possible to access the thr hi menu Maximum Threshold Setting set the upper totalisation threshold and press ENTER e Through the 501 function combinable with the desired key lt lt F KEYS gt gt step TECH MAN REF its possible to access the thr Lo menu Minimum Threshold Setting set the lower totalisation threshold and press ENTER NOTES By setting 0 in the maximum threshold it s possible to totalise up to the maximum capacity of the scale By setting 0 in both thresholds the functions are disabled The totalisation field is valid for all totalisation types in loading in unloading and in loading as well as in unloading 13 2 6 CONDITIONS FOR TOTALISATION With APPROVED instrument The MANUAL and AUTOMATIC totalisation works with a POSITIVE NET WEIGHT of at least 20 divisions in LOADING or a NEGATIVE NET WEIGHT of at least 20 divisions in UNLOADING The totalisation is reenabled depending on how the F ModE gt gt rEACt REACTIVATIONS parameter has been programmed the TECHNICAL SET UP TECH MAN REF The totalisation excludes the simple print function and vice versa With NON APPROVED instrument The MANUAL totalisation works with a NET WEIGHT greater than zero in LOADING or a NET WEIGHT lower than zero in UNLOADING The AUTOMATIC totalisation works with a minimum POSITIVE NET WEI
11. can proceed in two ways 1 Type the memory storage number and press F2 2 By pressing for an instant the F2 key to enter the customer database Select the storage using the arrow keys w by typing the storage number the LCD display shows the first corresponding DESCRIPTION line by searching the first description see section 11 2 7 Press ENTER To deselect a selected article for an instant press the F1 key to enter in the article database and press 2nd F Before unselecting a confirmation is requested press ENTER to confirm or another key to cancel 11 2 6 ENTRY MODIFICATION AND QUICK SELECTION OF CUSTOMER 000 possible to enter or modify quickly the customer 000 the number 0 using the numeric keyboard and press F2 The indicator is ready to enter modify the customer 000 once modified and confirmed with ENTER it is also selected The modification has effect also in the database 11 2 7 ALPHABETICAL RESEARCH The access to the ALPHABETICAL RESEARCH is possible in the following 2 ways 1 by pressing the F2 to access the database and by pressing the F4 key or 2 through function 310 combinable with the desired key lt lt F KEYS gt gt step TECH MAN REF To search a customer 1 Enter the desired characters to search in the first description of all the customers 2 Select the desired storage in the list of the result by using the arrow keys and press ENTER 3 Carry out one of t
12. case of 485 transmission mode 55 US instable weight ST stable weight OL weight out of range greater UL weight out of range lower comma character ASCII 044 B number of selected channel comma character ASCII 044 LLLLLLLLLL gross weight on 10 digits UU unit of measure comma character ASCII 044 YY 2 spaces in the case of null tare or semiautomatic tare PT in the case of preset tare TTTTTTTTTT tare weight on 10 digits comma character ASCII 044 ID XXXXX YYYYYY or NO weigh not stored in the alibi memory the gross weight is negative or unstable lt CROCRLF gt Terminator ASCII 13 and ASCII 10 characters 16 2 3 WEIGH READING Command II ALRDXXXXX YYYYYY CR o CRLF gt in which 11 485 address only case of 485 transmission mode XXXXX rewriting number from 0 up to 255 ASCII 045 character YYYYYY ID code lt CR o CRLF gt terminator ASCII 13 and ASCII 10 characters Instrument answer I BJLLLLLLLLLLUU YYTTTTTTTTTTUU CR o CRLF gt in which 11 485 address only case of 485 transmission mode B number of selected channel comma character ASCII 044 LLLLLLLLLL gross weight on 10 digits UU unit of measure comma character ASCII 044 2 spaces in the case of null tare or semi automatic tare PT in the case of preset tare TTTTTTTTTT tare weight on 10 digits lt CR o CRLF gt Terminator ASCII 13 and ASCII 10 characters 16 2 4 ALIBI MEMORY CANCELLATION only with non approve
13. few seconds on the display and will be added in the addition and multiplication case or subtracted in the subtraction case to the current tare value PRESS 2nd F the NET weight on the scale will be used as a second value and the result will be shown for a few seconds on the display In the end the printing of the CALCULATOR will be executed anyway See section 14 PRINTOUTS To disable the calculator function press the C key HELP FUNCTION By pressing at length the HELP key it is possible to see the list of the keys used in the calculator function If one wants to scroll the list of the keys in manual mode it is possible to use the arrow keys F6 F7 4 47 3590EKR 3590EXP 3590 CPWE CPWET series indicator E AF02 02 12 05 EN U 15 2 DISPLAY OF NET WEIGHT WITH SENSITIVITY X 10 for testing use during calibration By pressing at length the F2 key one will view the net weight with sensitivity times 10 press again at length the F2 key to return to the normal visualisation NOTES With approved indicator the visualisation lasts about 5 seconds after which it s disabled The printout can only be done when the indicator has the standard sensitivity 15 3 SETTING DATE TIME By pressing at length the F3 key it s possible to quickly access the setting from the date time of the instrument DAY gt ENTER MONTH ENTER YEAR gt ENTER gt HOUR gt ENTER MINUTES gt ENTER 15 4 SET POINT FUNCTION The
14. indicator is fitted with a series of 4 signal outputs used for various types of operation besides through the expansion board in the IO version it is possible to use another 12 In the SEtuP gt gt outPut gt gt r ConF menu TECH MAN REF it is possible to set the characteristics of each output which will be used normally open or normally closed upon direct control or weight stability with hysteresis or without the functioning mode It is also possible to set whether the enabling of the output excludes the check on the previous outputs see the SEtuP gt gt outPut gt gt r ModE parameter 15 4 1 NORMAL FUNCTIONING MODE By setting the SEtuP gt gt outPut gt gt r ModE parameter on norMAL one configures the independent use of the outputs the check is made on all the set outputs the enabling of one of these does not cause the disabling of the others 15 4 1 1 SETPOINT ON THE GROSS WEIGHT Functioning with hysteresis rL iSt HYSTERESIS parameter set as iSt on By selecting this functioning mode the output function on the GROSS weight is activated one enters two SETPOINTS for each output a DISABLING one which when the gross weight is lower than it disables the appropriate output an ENABLING one which when the gross weight is greater or equal than it it enables the appropriate output Through function 202 combinable with the desired key lt lt F KEYS gt gt step TECH MAN REF the SET POINT values are ent
15. is stored in the recalled position the indicator activates it 2 Press the Fn key followed by the TARE key to enter in the tare database Select the memory storage By using the arrow keys by typing the storage number with the keyboard the display shows the corresponding tare value 3 Press ENTER to enable the tare To deselect a selected tare for an instant press the TARE key or press C 7 4 6 HELP By pressing the HELP key it s possible to see the keys list used in the menu The key list is automatically shown If you want to see the keys list in manual mode use the arrow key F6 eF7 a 7 5 TARE CANCELLATION To cancel the stored tare With an unloaded platform press the TARE key With loaded platform press in sequence the numeric 0 key and TARE Press the C key CAREFUL this operation cancels also the executed reference 7 6 LOCKED UNLOCKED TARE Normally when there is this value by unloading the scale plate the display shows the tare value with a negative sign LOCKED TARE One can also choose that the tare value is cancelled automatically each time that the scale is unloaded UNLOCKED TARE CONDITIONS FOR AUTOMATIC UNLOCKING In case of SEMIAUTOMATIC TARE the net weight before unloading the scale may also be 0 In case of MANUAL OR CALCULATED TARE or FROM DATABASE the net weight before unloading the scale must be of at least 2 stable divisions If the F5 key is pressed at length it i
16. of digits shown by the instrument CPWE CPWET VISUALISATION WITH NON ACTIVE WEIGHT ZOOM The data is shown on two lines under the weight Pieces section by pressing in sequence the 2nd and F9 keys scrolls in order the following visualisations VISUALISATION WITH SELECTED ARTICLE WITHOUT SELECTED ARTICLE First article description or net gross weight Active scale and active semiautomatic tare if manual tare Total article weighs or weighs general total Active scale and active semiautomatic tare if manual tare Average piece weight Active scale and active 1 semiautomatic tare if manual tare First customer description Active scale and active 1 w semiautomatic tare if manual tare NOTE this visualisation is available with an active customer Total quantity of pieces article total weigs if a reference has not been executed Active scale and active semiautomatic tare if manual tare 25 3590EKR 3590EXP 3590 CPWE CPWET series indicator E AF02 02 12 05 EN U By proceeding with the pressing in sequence of the 2nd F and F9 keys the same visualisations will show up again with the 1s tare in the second line VISUALISATION WITH SELECTED ARTICLE WITHOUT SELECTED ARTICLE First article description or net gross weight H Active scale and 1 tare value if manual tare Total article weigh
17. one of the procedures described in section 13 1 press the F1 key to enter in the article database and with the arrow keys position on the article in which the A P W is to be updated press F10 the A P W in use is stored in the database by substituting the previous one The display shows for an instant the message UPDATE NOTE This operation enables the selected article and in the database replaces only the A P W of this article and not the one linked to the previously enabled eventual article 11 1 9 ALPHABETICAL RESEARCH The access to the ALPHABETICAL RESEARCH is possible in the following 2 ways 1 by pressing the F1 to access the database and by pressing the F4 key or 2 through function 309 combinable with the desired key lt lt F KEYS gt gt step TECH MAN REF To search an article 1 Enter the desired characters to search in the first description of all the articles 2 Select the desired storage in the list of the result by using the arrow keys and press ENTER 3 Carry out one of the operation described in the previous sections 11 1 10 HELP By pressing the HELP key it s possible to see the keys list used in the menu The key list is automatically If you want to see the keys list in manual mode use the arrow key F6 e F7 a 36 3590EKR 3590EXP 3590 CPWE CPWET series indicator E AF02 02 12 05 EN U 11 2 CUSTOMERS The indicator is fitted with a database in which it is possible
18. the partial total accumulated quantity the entry of the SET POINTS and the specifications are the same as the functioning mode on the gross weight 15 4 2 EXCLUSIVE FUNCTIONING MODE By setting the SEtuP gt gt outPut gt gt r ModE parameter on EXCLuS one configures the exclusive use of the outputs The check is made on all the set outputs starting from the last one OUT 16 to the first one OUT 1 When one of these is enabled the check on the previous ones is excluded By selecting this functioning mode and setting the set points in increasing order one can create outputs activation ranges Useful for the functioning with the control light for tolerance check Example OUTPUT SETPOINT ACTIVATION RANGE OUT 1 1 000 kg From 1 000 to 1 999 OUT 2 2 000 kg From 2 000 to 2 999 OUT 3 3 000 kg From 3 000 to 3 999 OUT 4 4 000 kg From 4 000 onwards In this case if the weight reaches 2 500 kg ONLY THE OUTPUT2 IS ENABLED if the weight reaches 4 500 kg ONLY THE OUTPUTA IS ENABLED 50 3590EKR 3590EXP 3590EXT CPWE CPWET series indicator E AF02 02 12 05 EN U 15 4 3 QUICK MODIFICATION OF THE SETPOINTS By linking the number of a specific setpoint to the function 202 preamble function in the lt lt F KEYS gt gt step TECH MAN REF it is possible to access directly to the modification of it with a direct key for example F1 key to quickly modify the SETPOINT 1 and F2 key to quickly modify the SETPOINT 2 15 5 DIAGNOSTIC P
19. times the printing of the selected article total F KEYS gt gt step TECH MAN REF SELECTED ARTICLE TOTAL CALCULATOR see section 15 1 Automatic entry SF 08 PRINT AT IGNITION Automatic entry SF 09 The instrument is fitted with 30 print formats in other words 30 different storages each of which contain a programmable printout The formats are programmable in the SEtuP gt gt SEriAL gt gt Prn FMt step in the SET UP environment TECH MAN REF Its possible to quickly link a stored format to each print function listed in the table this function allows also to execute various printouts with the same print function changing the linked format from time to time TO LINK THE FORMAT e Recall function 200 combinable with the desired key lt lt F KEYS gt gt step TECH MAN REF 200 SF 01 gt F 01 e The display shows XX in which XX indicates the number of the function from 01 onwards to which the print format is linked Select the print function for example S F 01 through the arrow keys and press the ENTER key entered the display shows in which indicates the number of the format to be linked e the format number and press ENTER NOTE In order to not link any format to a vector one should enter the number 00 14 1 1 QUICK LINKING OF THE FORMATS By linking the number of a specific print function to the functi
20. to customise the functionality of the keys through the lt lt F KEYS gt gt step Turns the instrument on off C DEL f pressed for an instant it clears the tare value Exits the parameter without confirming and saving the modifications In the numeric input phase it quickly clears the present value If pressed for an instant it carries out the semiautomatic tare or cancels the tare value if the gross TARE ZERO weightis 0 If pressed at length it clears the displayed gross weight if it s within the percentage configured in the lt lt 0 PErC gt gt step Fn ENTER n the alphanumeric input phase it confirms the entry made n the menu it allows to enter a step or to confirm a parameter inside a step If pressed together with the other keys it allows carrying out a specific function see section 4 1 1 In the lt lt F Keys gt gt step if pressed for an instant the list of the available functions appear and it is possible to choose one of them 2ndF KEY SECOND FUNCTION OF THE KEYS If pressed in some steps or functions of the weight indicator the display shows the keys and their functions specific to that state of the instrument JHELP In the numeric or alphanumeric input phase it enters in this order the following characters lt gt amp HELP function see section 4 1 4 3590EKR 3590EXP 3590 CPWE CPWET series indicator E AF02 02 12 05 EN U
21. two lines in the CPWE depending on the weight zoom function see following section See section 4 2 5 1 2 2 ARTICOLO 1 1 1 250kg Figure 2 CPWE display NOTE If the EEEEE message appears this means that the value exceeds the maximum number of digits shown by the instrument 4 2 1 WEIGHT ZOOM The zoom function allows to increase the size of the weight digits in order to ease the reading from a distance with the active zoom the data is shown on a single line 0 000 GROSS 1 450kg Through the lt lt ZOOM W gt gt step one can disable enable the function and set a delay which determines the activation mode always active function with delay equal to 0 or disabled function at the pressing of a key and reenabled automatically when the keyboard inactivity time reaches the configured delay period with delay greater than 0 21 3590EKR 3590EXP 3590 CPWE CPWET series indicator E AF02 02 12 05 EN U 4 2 2 STATUS INDICATORS FUNCTION Indicates the type of indicator power supply red pilot light through built in power adapter green pilot light through battery charged battery pilot light off through battery discharged battery Indicates that the weight detected by the weighing system is near zero including the interval of 1 4 1 4 of the scale s division BEEN Indicates that the weight is unstable Indicates that the weight shown by the display is a NET WEIGHT
22. usable remote controls To enable this mode one has to first select RD 6 BR in the lt lt inF Red gt gt TECH MAN REF USE OF MORE REMOTE CONTROLS WITH SEVERAL INDICATORS IN THE SAME AREA If one needs to use several indicators in the same area it is possible to combine each remote control to the desired indicator in order to execute the function only on it and therefore avoid emulating the function on all indicators in use By enabling this mode it will be possible to combine up to 3 different remote controls e i for 3 different operators for each indicator To enable this mode one has to first select RD 6 in the lt lt inF Red gt gt TECH MAN REF To link a new remote control to the indicator one has to press at length 1 and 2 keys together 3 seconds the instrument displays aut rd press the ENTER key of the indicator the new remote control is linked To remove the linking of a remote control one has to press at length 1 and 2 keys together 3 seconds the instrument displays aut rd press the C key of the indicator if the remote control was previously linked it will be removed 20 3590EKR 3590EXP 3590EXT CPWE CPWET series indicator E AF02 02 12 05 EN U 4 2 FUNCTION DISPLAY During the weighing the displays are subdivided mainly in 3 sections shown in the figure below 1 WEIGHT 2 STATUS INDICATORS led pilot lights or graphic symbols 3 DATA two lines in the 3590E one or
23. with the desired key lt lt F KEYS gt gt step TECH MAN REF it s possible to modify or clear the TICKET PROGRESSIVE up to 5 digits The TICKET PROGRESSIVE is a progressive number which increments of one UPON THE FIRST TOTALISATION SUBSEQUENT TO THE CLEARING OF THE PARTIAL TOTAL 13 2 10 4 LOT PROGRESSIVE Through function 405 combinable with the desired key lt lt F KEYS gt gt step TECH MAN REF one obtains the clearing of the AUTOMATIC LOT up to 6 digits before carrying out the actual clearing one is asked to confirm or cancel the operation confirm with ENTER The AUTOMATIC LOT is a progressive number which increments of one UPON THE FIRST TOTALISATION SUBSEQUENT TO THE CLEARING OF THE GENERAL TOTAL 14 PRINTOUTS The instrument is fitted with different print functions which may be used while weighing and of 30 print formats in other words 30 different memory storages each of which contain a programmable printout The printouts made by some of these functions depends on the print format linked to it see the following section for the linkages The format linking function allows executing various printouts by changing the linked format each time The available functions are SIMPLE PRINTOUT Programmable printout Through the PRINT key F5 key one prints the linked format With the APPROVED instrument printing works if there is NET WEIGHT of at least 20 divisions or a NEGATIVE NET WEIGHT of a
24. 3590EKR 3590EXP 3590EXT CPWE CPWET series indicator E AF02 02 12 05 EN U TOTAL OF EACH HANDLED ARTICLE Programmable printout Through function 306 combinable with the desired key lt lt F KEYS gt gt step TECH MAN REF for each article whose net total shows to be greater than 0 the resetting of the ARTICLE TOTAL and the printing of the linked format are made SELECTED ARTICLE TOTAL Programmable printout With a selected article by pressing the 2ndF and F1 keys the resetting of the ARTICLE TOTAL is made and the linked format is printed RESULT OF THE CALCULATOR Programmable printout Once terminated the operation with the CALCULATOR function the linked format is printed See section 15 1 LIST OF LAST 50 EXECUTED WEIGHS Fixed printout Its possible to print the last 50 totalisations executed by the instrument subdivided by NET weight GROSS weight and TARE weight linking the function corresponding to the desired key lt lt F KEYS gt gt step TECH MAN REF SAMPLE LIST CODE FUNCTION FOR PRINTOUT GROSS TARE WEIGHS REPORT PRINTING Fixed printout Through function 418 combinable to the desired key lt lt F KEYS gt gt step it s possible to print a list which shows DATE AND TIME DESCRIPTION NUMBER OF executed WEIGHS and the NET WEIGHT TOTAL of each ARTICLE with which totalisations have been made At the end of the list the TOTAL NUMBER of the executed weighs and t
25. 3590EXT CPWE CPWET series indicator E AF02 02 12 05 EN U 11 DATABASE 11 1 ARTICLES The indicator has a database in which it is possible to store up to 1000 articles having three descriptions of 20 characters each article is linked to a storage number from 0 to 999 The selected article is shown on the display during the weighing operations and can be printed through the relative print block dris ii Linking APW IEEE Hee A X Ee Ee Er Database OE nanese ze _ GE _ n gt Me 11 1 1 ENTRY 1 Press the F1 key to enter in the article database NOTE we advise to leave empty the memory storage 0 since it is used for the temporary entry see section 11 1 6 TEMPORARY ENTRY 2 Select the eventual desired position By using the arrow keys 4 with the keyboard by typing the storage number 3 Press F1 to insert the article in the desired position or with the first free position if an already occupied position has been selected 4 One should fill in the following fields only the necessary ones are requested press ENTER to confirm DESCRIPTION 1 first description line up to 20 characters DESCRIPTION 2 second description line up to 20 characters e DESCRIPTION 3 third description line up to 20 characters e A P W average piece weight e LINKED TARE linking of a TARE IN THE DATABASE the display shows the number of the tare in the database from 0 to 299 while the d
26. 93 OE SEED CHR TE HME c Y O O0 48 SETPOINT FUNG 48 15 4 1 NORMAL FUNCTIONING iis eot Eon hat 48 152 Toe POINT THE GROSS WEIGH E 48 15 512 SETPOINT ON TENET VIEIGPUI Iu ERS 49 194 3 GROSS WEIGHT AT ZERO e ette tele re estere beate 49 Sm WEICH ATZER O 49 m E VIS Tr NM E 49 E 49 194 SETROINTON THE PAR esse ee 49 194 1 5 Oe POINT ON IHE GENERAL TO TAE se SA E 49 194519 SETPOINT ON THE GRAND brit 49 1541 10 SETPOINT ON THE NEGATIVE WEIGHT 49 POS AW SETPOINT ON QUANTITY eS 50 15 4 1 12 SETPOINT ON THE NEGATIVE QUANTITY 50 15 4 1 13 SETPOINT ON THE PARTIAL TOTAL QUANTITY sessed 50 O42 EXCEUSIVETUNSTIONING NODE ctt tiet Rude i te eese tasa nae t 50 15 4 3 QUICK MODIFICATION OF THE SETPOINTS sss 51 O ss SSS EEE TO 51 19 0 COM DATA DIAGNOS TIG P E 51 16 AEIBUMEMONRY OR De E ee en EAS EE 52 16 READING OF EHE WEIGHS OU ree Re 53 16 2 SERIAL COMMANDS FOR MANAGIN
27. By entering a number through the numerical keyboard and then pressing the F1 key one can quickly select the article corresponding to the entered value the article must have already been edited In the numeric or alphanumeric input phase it allows to copy entered characters If pressed for an instant it enters into the article database If pressed at length it locks and unlocks the instrument s keyboard except the C key In the numeric or alphanumeric input phase it allows to stick with copied characters If pressed for an instant it enters into the customer database If pressed at length the weight visualisation function with sensitivity x 10 is enabled If pressed for an instant it allows to manage the set point configuration If pressed at length one can adjust the date and time of the instrument If pressed for an instant it allows to fill in the free texts if configured If pressed at length it enters the instrument s diagnostics menu If pressed at length it locks unlocks the tare Commands the data transmission to the printer serial port If pressed for an instant it carries out the totalisation In the numeric or alphanumeric phase it decreases the blinking digit It allows scrolling ahead inside the menu steps or in the parameters within a step If pressed for an instant it allows entering the number of pieces for the reference In the numeric or alphanumeric input phase it inc
28. CEL PRINTOUT repeat it through the procedure described in section 14 3 PRINTER ERROR Error during the printing totalisation not possible or printing not executed CHECK THE CTS finished USER PRESS KEY See section 12 3590EKR 3590EXP 3590EXT CPWE CPWET series indicator E AF02 02 12 05 EN U DECLARATION OF CONFORMITY This device conforms to essential standards and to other norms pertaining to applicable European regulations The Declaration of Conformity is available on the www diniargeo com web site WARRANTY The TWO YEAR warranty period begins on the day the instrument is delivered It includes spare parts and labour for repairs at no charge if the INSTRUMENTS ARE RETURNED prepaid to the DEALER S PLACE OF BUSINESS Warranty covers all defects NOT attributable to the Customer so are not included in the warranty failures resulting from improper use and NOT caused during transport If on site service is requested or necessary for any reason where the instrument is used the Customer will pay for all of the service technician s costs travel time and expenses plus room and board if any The customer pays for shipping costs both ways if the instrument is shipped to the DEALER or manufacturer for repair The WARRANTY is VOIDED if faults occur due to work done by unauthorised personnel or due to connections to equipment installed by others or incorrect connection to the power supply This warranty DOES NOT pr
29. ERIPHERALS Through function 118 combinable with the desired key lt lt F KEYS gt gt step TECH MAN REF one enables the diagnostic peripherals function The display shows STATUS DESCRIPTION ANALOGUE OUTPUT A O Analogue output value expressed as a percentage OUTPUTS OUT Status output non active 52 or active T INPUTS IN otatus input non active or active 2 SERIAL COMUNICATIOS Tx The serial communication is active with external device otatus of the weight WEIGHT unloaded scale unstable weight Number of the active scale example 1 see section 5 SCALE SELECTION the relative weight loaded 15 6 COM DATA DIAGNOSTIC Through function 119 combinable with the desired key lt lt F KEYS gt gt step TECH MAN REF one enables the Com data diagnostic function The display shows In the first screen one selects the port on which the diagnostic control should be executed While in the second screen one selects the code that one wants to use for viewing the data in transit When the data on the RX and TX reception and transmission lines are correctly displayed then the functioning of the relative serial line is considered to be correct NOTE By pressing the HELP key it s possible to see the keys list used in the menu 51 3590EKR 3590EXP 3590EXT CPWE CPWET series indicator E AF02 02 12 05 EN U 16 ALIBI MEMORY The alibi memory allows storing the executed we
30. G THE ALIBI 1 eese 53 162 REQUEST WEIGHT VALUE WITH WV EMG ID dh n eei b eot oett e e tee 53 10 22 STRING FORMAT WEIGH rro tuae titus Posee subeat bea 54 10 23 WEIGH READING Reden M Ie SU Md DR MIU ID MEM DIM M E IE 54 16 2 4 ALIBI MEMORY CANCELLATION only with non approved 54 AN Iur cl P A E 55 TEALINSIDE THE SE EUR OR MENU OR AT STAIS TUP edi 99 ERA Esel ce I 56 DECLARATION OF CONFORMITY 57 WARRANTY 57 3590EKR 3590EXP 3590 CPWE CPWET series indicator E AF02 02 12 05 EN U 1 INTRODUCTION This manual was created to help you install and learn all about the functional possibilities of the purchased indicator The instrument is suitable for use in various weighing environments Not only does it have all the normal features of high precision scales but it also gives you the possibility to work in specific environments due to the functioning modes contained in the software implemented in the FLASH MEMORY on the internal board This makes the instrument extremely flexible and it can be used in many different industrial applications linked to weighing The double numerical and interactive
31. GHT of at least 10 divisions in LOADING or a NEGATIVE NET WEIGHT of at least 10 divisions in UNLOADING The totalisation is reenabled depending on how the F ModE gt gt rEACt REACTIVATIONS parameter has been programmed in the TECHNICAL SET UP TECH MAN REF The totalisation does not exclude the simple print function 13 2 7 PRINT REENABLING AND TOTALISATION When the indicator is used it is possible to incur in the WEIGHT NOT PASSED BY 0 OR INSTABILITY error shown on the display this means that the function which one wants to execute must be reenabled in order to avoid accidental executions It is possible to set the reenabling of the function in the following modes passage by net zero of the weight reenabling upon weight instability or always enable see the F ModE gt gt rEACt parameter of the set up parameter TECH MAN REF 42 3590EKR 3590EXP 3590EXT CPWE CPWET series indicator E AF02 02 12 05 EN U 13 2 8 VISUALISATION AND CLEARING OF THE ACCUMULATED TOTALS Each total can be momentarily viewed on the display or cleared independently through the printout linking the function corresponding to the desired step lt lt F KEYS gt gt step TECH MAN REF TOTAL FUNCTION CODE FOR PARTIAL TOTAL 46 GENERAL TOTAL GRAND TOTAL ARTICLE TOTAL only with selected article WEIGH LIST ALL SCALE TOTALS including weighs lists except the article total ALL ARTICLE TOTALS By
32. KEYS gt gt step TECH MAN REF The relative weight data is also printed see section 14 13 2 10 PROGRESSIVES 13 2 10 1 ADDITIONAL VALUE Through function 402 combinable with the desired key lt lt F KEYS gt gt step TECH MAN REF it s possible to set a value of up to 6 digits which is summed to each totalisation and can be recalled in the printing The same value is linked independently to three total types PARTIAL GENERAL and GRAND TOTAL in other words it is possible to print three different values which will be cleared with the clearing of the relative total 13 2 10 2 PROGRESSIVE DIGITS Through function 403 combinable with the desired key lt lt F KEYS gt gt step TECH MAN REF it s possible to set the number of digits with which the TICKET PROGRESSIVE and LOT PROGRESSIVE are printed The number of settable digits varies from 4 to 16 organised in this way if the actual digits of the total are less than the number of digits set in this step the difference is filled with some spaces if the actual digits are greater than the number of digits set in this step only the ones actually entered are taken into consideration counting from right to left The alignment of the total fields is on the left NOTE The number of settable digits DOES NOT INCLUDE the comma 43 3590EKR 3590EXP 3590EXT CPWE CPWET series indicator E AF02 02 12 05 EN U 13 2 10 3 TICKET PROGRESSIVE Through function 404 combinable
33. OWER the instrument through the 240 Vac mains or TO RECHARGE the battery insert the plug and the adapter to the 240 Vac mains socket The CPWE indicator is powered with 824 Vdc voltage or with 6 Vdc external battery upon request he CPWET indicator is powered with 12 Vdc voltage or with 6 Vdc external battery upon request To connect the indicator to the power mains the safety regulations must be observed including the use of a clean line without disturbances or interference caused by other electronic equipment Version with rechargeable battery The battery inside the indicator lasts about 25 hours without the expansion board with 1 cell platform and it needs a recharging time of about 12 hours BATTERY FEATURES Material LEAD Power 4 5 Ah Voltage THE BATTERY MUST SUPPLIED DIRECTLY FROM THE MANUFACTURER NOTE it is advisable to completely recharge it 12 hours in the first installation of the instrument we RECOMMEND disconnecting the battery if the instrument is not going to be used for more than 30 days Do not connect other equipment to the same socket as the one that the adapter is in Do not step on or crush the power supply cable 3 6 START UP TO TURN ON the 3590E or the CPWET press the C key until the display turns on then release The CPWE instead is automatically turned on as soon as it is powered The LCD display shows Initially a welcome message settable in the TECHNICAL SET UP lt lt LoGo
34. RU a 33 3590EKR 3590EXP 3590 CPWE CPWET series indicator E AF02 02 12 05 EN U 10 FILLING IN THE INPUT TEXT cH DER UII ERR S RR CO MEHR RR I EM M DOMUS 33 tB UID EUER MUI O 34 ARTICLES ER E 34 SS c sed edt 34 TEZ MODIFICATION m 35 HAS 35 EUST asd HINC TEN 35 ILS SEDECHONTDESBEECT ID 35 11 1 6 ENTRY MODIFICATION AND QUICK SELECTION OF ARTICLE 000 35 11 1 7 ENABLING SET POINT VALUES LINKED TO THE ARTICLE sss 36 111 8 LINKING OF THE A P W IN USE TO AN AR HOLE e 36 ALPEIABETIGAE SESEAROEIL i REDI UR 36 mer 36 Xe IS cl 37 x sede P 37 TASA 37 L2 SING ELIE VIOIN m MM 38 aco ettet an vet seca RU Mb cn co UR RA melon ed tation Ganda VR DATED pubs RR CUN UM UE 38 Tis ON DESEEE CO HON O 38 11 2 6 ENTRY MODIFICATION AND QUICK SELECTION OF CUSTOMER 000 38 112 ALPHABETICAL RESERBRCLTIT a rn a aut dela E On didi o tesi ERR RN a Cd 38 OME sert 38 12 DATABASE ACCESS PASSWORD iius Scent a
35. TECHNICAL DEFAULT dFLt t parameter of the SET UP environment and carefully carry out the calibration The value 0 is in the diV 1 parameter of the calibration one must execute a TECHNICAL DEFAULT dFLt t parameter of the SET UP environment and carefully carry out the calibration Err 37 No Cal Err 39 No Cal has been used e been calibrated ene mii pk ana read HARDWARE ERROR software not compatible with the installed hardware the hardware expansion component is missing which allows the software to function SAVE confirm or C to not continue or C to not continue Generic error Possible motives can be Division not valid please check that DIVISION 1 DIVISION 2 DIVISION 3 An error has taken place in the connection configuration equalisation calibration of the cells etc EXECUTION nem AUTOZERO autozero at start up function is active see section 3 3 NOTE if the Er XX error appears after the indicator start up press the TARE key to enter in the SET UP environment 3590EKR 3590EXP 3590EXT CPWE CPWET series indicator E AF02 02 12 05 EN U 17 2 IN WEIGHING MESSAGE DESCRIPTION Printing or totalisation not possible with weight at 0 negative unstable or out of WEIGHT the totalisation field D INSTABILITY INSTABILITY or by instability gt POWER OFF Turning off of the instrument through the key see section 3 3 OVERLOAD
36. ULTIRANGE AND MULTIDIVISION FUNCTION The multi range functioning allows to subdivide the scale capacity in two or three ranges each of which is up to 3000 divisions improving in this way the first range division in the dual range and the first two ranges in the triple range For example it is possible to approve the weighing system with A single range 6 kg capacity and 2 g division 3000 div Dual range 6 3 kg capacity and 2 1 g division 3000 3000 div Triple range 15 6 3 kg capacity and 5 2 1 g division 3000 3000 3000 div NOTE For the approval of the weighing system in dual and triple ranges the cell must have better technical features in comparison to the cell used for the approval in a single range This functioning is indicated by the turning on of the indicator which identify the range in which one is working W1 first range W2 second range W3 third range if configured by passing to the W2 range the second range division is enabled by passing to the W3 range the third range division is enabled at this point the W1 first scale division is restored only by passing the gross zero of the scale The multidivisional functioning is similar to multirange but with the difference that a range division is enabled as soon as one enters in its range interval in other words without passing by the scale zero NOTE The selection of the range number with multirange and multidivisional functioning is made during the indi
37. USER MANUAL WEIGHT INDICATOR E AF02 PROGRAM VERSION FOR QUANTITY PIECES LITRES ETC COUNTING SYSTEMS LINE 1 HEADER N LINE 2 HEADER LINE 3 HEADER OE TIOIN NET er PILE WOSHI 5 0971002010 12 00 00000 009123 4 4 ii E AF02_ 02 12 05 3590EKR 3590EXP 3590 CPWE CPWET series indicator E AF02 02 12 05 EN U INDEX INTRODUCTION masa hrs LTD UE t DM EID 9 2 MAIN pene e 2l que rem 6 2 AUGESSURIES AVAILABLE dada Mc oam pub stp cu ORS ER SM I EMITE UN GENI 74 2 2o ai 1518 Ron Ws sp ee er er ee ee ee er INSTALLATION Tr 8 3 1 CPWE DRILLING TEMPLATE CASE AND DIMENSION 8 2 2 99905 CASE AND DIMENSIONS bidon a max abet ori tase daira EE I iain 9 SS GPNEPOASEAND DIMENSIONS xdi Ue REND DU RR MA MESRINE UM RE POE DM MN DUM IM MIN MEUM E DINE 11 CPWETD CASE AND DIMENSIONS isi 12 SOT OMER On ere meee E 13 S edP IMS e T 13 9 4 TURNING ORE THE ANSTIRUMEN T desde E oct tan cap tn nn i uh 13 3 8 TURNING ON PRINTER IN ENERGY SAVING MODE ditte pae ortu eh ebur post up cott buts 14 4 FRONT PANEL KEYS AND DISPLAYS eeeeeeeeeeeeeeneennnenennennnnn nennen netten nenne tein itin tein stains tnn 14 A TEUNGIIONOF THE KEYS as
38. ailable hardware and software accessories 2 2 SYMBOLS USED Below are the symbols or texts used in the manual to recall the reader s attention and on the instrument to recall the user s attention ATTENTION This is referred to working with live wires only qualified personnel must perform this operation ATTENTION Only qualified personnel must perform this operation IDENTIFIES THE CLASS OF PRECISION T It means that an advanced function is being described therefore for the technical personnel TECH MAN REF which will be further explained in the corresponding sri manual THE INSTRUMENT S DANGEROUS VOLTAGE PARTS AND THE PARTS THE USER CAN ACCESS HAVE BEEN ELECTRICALLY INSULATED 3590EKR 3590EXP 3590EXT CPWE CPWET series indicator E AF02 02 12 05 EN U 3 INSTALLATION 3 1 CPWE DRILLING TEMPLATE CASE AND DIMENSION The weight indicator has an anodized aluminium case whose external dimensions are shown in the figure 1 It should be mounted on a panel board respecting the safety norms OD OD OD OD OD D D D D D D OD OD OD OD OD OD D OD OD OD OD OD OD Figure1 DRILLING TEMPLATE DIMENSION 187 5mm x 91 5mm 8 3590EKR 3590EXP 3590EXT CPWE CPWET series indicator E AF02 02 12 05 EN U 3 2 3590E CASE AND DIMENSIONS The indicator has an IP65 ABS case whose external dimensions are shown in the Figure 2 It can be simply
39. article for an instant press the F1 key to enter in the article database and press 2nd F Before unselecting a confirmation is requested press ENTER to confirm or another key to cancel 11 1 6 ENTRY MODIFICATION AND QUICK SELECTION OF ARTICLE 000 possible to enter or modify quickly the article 000 the number 0 using the numeric keyboard and press F1 The indicator is ready to enter modify the article 000 once modified and confirmed with ENTER it is also selected The modification has effect also in the database 35 3590EKR 3590EXP 3590EXT CPWE CPWET series indicator E AF02 02 12 05 EN U 11 1 7 ENABLING SET POINT VALUES LINKED TO THE ARTICLE By enabling an article the linked QUANTITY SET POINTS values are set in the values of the eventual SET POINT functions enabled on the rL 1 rL 2 rL 3 outputs through the rLFunC parameter The relays are managed in the SEtuP gt gt SEriAL gt gt outPut step TECH MAN REF N B The configured SET POINT values are valid only for the activation functions per quantity See section 15 4 for the SET POINT functioning specifics IMPORTANT For the correct functioning of the set points linked to the article at least the rL 1 outputs must be programmed with the functioning on the quantity 11 1 8 LINKING OF THE A P W IN USE TO AN ARTICLE possible to quickly link the A P W in use to a stored article one should enter or calculate the A P W by following
40. ba 39 13 COUNTING AND TOTALISATION PROCEDURES eese nennen 39 press FUNCTION c 39 13 1 1 COUNTING IN LOADING WITH ENTRY OF THE REFERENCE 39 T9 T 2 MINIMUM SAMPLE WEIGHT n EE on ex e ted nS a ald UO an 39 OP TIMISATIONAOE TIE AT VV tien usa eae E ip ua onte enimad 39 13 1 4 COUNTING WITH THE ENTRY OF THE KNOWN A P W 40 T9 GOUNTINO JN EXTRAG TION MR nin ROCA 40 19 MOS OUNTING OFTHE REMNANT se duxi tta eic Deb ota neg Pu Axe Becomes 40 13 1 7 COUNTING WITH THE USE OF THE DATABRBSE alien 40 13 1 8 COUNTING WITH 2 OR MORE CONNECTED SCALES sese nnn 40 13 2 WEIGHT AND QUANTITY TOTALISATION 41 19 Zl ROTAEISATIONIMO DES wh RG A E ci ana MM OR VE M E MeL 41 OZ TOTALSER IN LOADING Sse 41 19 2 1 2 TO LAEISER IN UNLOADING taie pua baie ee 41 13 2 1 3 TOTALISER IN LOADING AS WELL AS IN UNLOADING nn 41 13 2 2 TOTALISATION WITH AUTOMATIC EXECUTION OF THE nn 41 13 2 3 MANUAL OR AUTOMATIC TOTALIZATION sessseeeeeennnnnnnnnnnnnnnnnenn 41 19 24 TOTALA TON DELA V usto beta ach td dum dau M atr LM
41. by typing the storage number with the keyboard the LCD display shows the first corresponding DESCRIPTION line Press F2 select the field to be modified by using the arrow keys press ENTER Modify the value and press ENTER to confirm Restart from point 4 to modify other fields or press C to return to the list of storages Restart from point 2 to modify other storage or Press the C key to return to the weighing phase NI OD ee 37 3590EKR 3590EXP 3590 CPWE CPWET series indicator E AF02 02 12 05 EN U 11 2 3 CANCELLATION 1 Press the F2 key to access the database to enter in the customer database 2 Select the storage to be modified by using the arrow keys 4 by typing the storage number the LCD display shows the first corresponding DESCRIPTION line 3 Press F3 4 Theindicator requests a further confirmation press ENTER to confirm or another key to cancel 9 Restart from point 2 or Press the C key to return to the weighing 11 2 4 PRINTING 1 Press F2 to enter in the customer database 2 inside the customer database menu press the F5 key The display shows the message PRINT confirm with the ENTER key to print the whole customer database which shows all the relative fields for each stored customer 11 2 5 SELECTION DESELECTION With no memory storage selected the LCD display shows in the data section see 4 2 section To select a stored customer one
42. cator Furthermore it is possible also to carry out all the reference and counting operations described in section 13 by using also the article database For the connection refer to the technical manual of the instrument TECH MAN REF CONFIGURATION OF THE REMOTE SCALE See the manual of the remote scale CONFIGURATION OF THE INDICATOR Refer to the technical manual for programming the indicator SEtuP gt gt SEriAL gt gt CoMAuX gt gt rEM SCA step TECH MAN REF 28 3590EKR 3590EXP 3590 CPWE CPWET series indicator E AF02 02 12 05 EN U 6 SCALE ZERO FUNCTION With various connected scales select the scale using the numerical keyboard using the 2ndF and the 1 2 3 and 4 keys Keep the ZERO key pressed the message Zero appears on the display after which If the weight on the scale is included in the percentage configured in lt lt 0 PErC gt gt RIF MAN T step it is zeroed If the weight is not within this range it will not be cleared and an error sound is emitted In the end the indicator automatically returns to the display of the weight present on the scale 6 1 CYCLICAL AUTOMATIC ZERO If the cyclical automatic zero has been set at the start up in the SEtuP gt gt ConFig gt gt ParaM gt gt Auto 0 step of the setup TECH MAN REF by pressing the combination of the 2ndF and ZERO keys a zero cycle is executed in all the current scales 7 TARE FUNCTIONS 7 1 SEMIAUTOMATIC TARE By pres
43. cator calibration TECH MAN REF 32 3590EKR 3590EXP 3590EXT CPWE CPWET series indicator E AF02 02 12 05 EN U 9 DISPLAY OF METRIC DATA inFO The indicator is fitted with a function named INFO thanks to which it is possible to view the configuration metric data First range capacity first range minimum weigh first range division Second range capacity second range minimum weigh second range division hird range capacity third range minimum weigh third range division NOTES he minimum weigh corresponds to 20 net weight divisions The data of the second and third range appear only if actually configured To display the metric data Press in sequence the 2ndF and C key METROLOGICAL INFORMATION is displayed The display will show the number of the scale the type of displayed data and its value Press the F6 key to quickly scroll the data Press the F7 key to quickly scroll the previous data backwards Press the C key to quickly return to weighing 10 FILLING IN THE INPUT TEXT The indicator offers the possibility of using 15 CONFIGURABLE INPUT TEXTS for example LOT OPERATOR SHIFT etc each made up of 16 heading characters and 32 content characters When entered in the TECHNICAL SET UP see F ModE gt gt tXt Input text configuration parameter TECH MAN REF these may be printed later on if programmed in the printouts or these may be used as a reminder 1 Press F4 for an ins
44. cifications are the same as the functioning mode on the gross weight 15 4 1 8 SETPOINT ON THE GENERAL TOTAL By selecting this functioning mode the output function on the sum between the NET weight present on the scale and the accumulated net general total is enabled the entry of the SETPOINTS and the specifications are the same as the functioning mode on the gross weight 15 4 1 9 SETPOINT ON THE GRAND TOTAL By selecting this functioning mode the output function on the sum between the NET weight present on the scale and the accumulated net grand total is enabled the entry of the SETPOINTS and the specifications are the same as the functioning mode on the gross weight 15 4 1 10 SETPOINT ON THE NEGATIVE NET WEIGHT By selecting this functioning mode the output function on the NET NEGATIVE weight is enabled the entry of the SETPOINTS and the specifications are the same as the functioning mode on the gross weight 49 3590EKR 3590EXP 3590EXT CPWE CPWET series indicator E AF02 02 12 05 EN U Functioning with hysteresis rL iSt HYSTERESIS parameter set as iSt on By selecting this functioning mode the output function on the NEGATIVE NET weight is activated one enters two NEGATIVE SET POINTS for each output a DISABLING one which when the NET weight is greater than it disables the appropriate output an ENABLING one which when the NET weight is lower or equal than it it enables the appropriate output The entry and specifica
45. d instrument Command CR o CRLF gt in which 11 485 address only case of 485 transmission mode Instrument answer CR o CRLF ifthe cancellation has been carried out effectively IITJALDLNO CR o CRLF ifthe cancellation has not been carried out effectively 54 3590EKR 3590EXP 3590 CPWE CPWET series indicator E AF02 02 12 05 EN U 17 MESSAGES While using the indicator it is possible to incur into the following errors 17 1 INSIDE THE SET UP OR MENU OR AT START UP MESSAGE DESCRIPTION 8 03 When carrying out the multirange or multidivisional calibration the ranges have not d been entered in an increasing manner RANGE 1 RANGE 2 RANGE 3 During the calibration some internal negative points have been calculated Err 36 No Cal the calibration point is less than the zero point the signal is negative check the connections During the calibration some internal points less than the minimum value have been calculated the calibration point is equal to the zero point capacity too high in relation to the division has been set Invalid calibration range number there is the value 0 or values greater than 3 one must execute a TECHNICAL DEFAULT dFLt t parameter of the SET UP environment if not already executed previously and carefully carry out the calibration The value 0 is in the range 1 parameter of the calibration one must execute a
46. dicator E AF02 02 12 05 EN U 7 4 TARE DATABASE The indicator has a database in which up to 300 prefixed tare values can be stored for each connected scale each tare value is linked to a storage number from 0 to 299 To access the database menus press the Fn key followed by the TARE key with an instrument normally turned on ACCESS Kev MENU Tara Database jee tArdth Pm _ t xX Ene Select _ e Deselect 5 NOTE If the access password has been set in the F ModE gt gt dtb PWd SET ACCESS PASSWORD parameter of the SET UP TECH MAN REF the entry modification or cancellation of an element in a database it is possible to only enter the password see section 12 7 4 1 ENTRY 1 Press the Fn key followed by the TARE key to enter in the tare database 2 Select the eventual desired position by using the arrow keys w with the keyboard by typing the storage number 3 Press F1 to enter the tare in the desired position or in the first free position if an already occupied position has been selected 4 The display is ready for the entry of the tare value digit the desired value and press ENTER to confirm 5 Restart from point 2 or press C to return to the weighing phase 7 4 2 MODIFICATION 1 Press the Fn key followed by the TARE key to enter in the tare database 2 Select the storage to be modified by using the arrow keys 4 by typing the storage number with the keyboard the display sh
47. dle of a text If pressed a few times it allows entering the following characters lt gt amp In characters mode ChAr by pressing once a space is entered by pressing twice it enters the 0 character In characters mode ChAr pressed repeatedly it allows to enter the following symbols 2119 2 T 9 OEZI 0eZ nX 8 70 2 G 2 23 Uq 1 4 72 74 j a o Moves the blinking cursor to the left or to the right scrolls in one sense or the other the list of all the enterable characters 0 1 9 A B Y Z Examples To enter the letter B one should press the 2 key twice in the ChAr mode To enter the number 3 one should press the 3 key four times in the ChAr mode or press the F5 key one passes to the nuM mode and press the 3 key once 4 1 3 DISABLING THE KEYBOARD It is possible to disable all the all keyboard functions except the C key for turning on and off in order to avoid undesired pressings of the scale keys To lock the keyboard press at length the F1 key the display shows the LoCK message for a few instants Now the keyboard is LOCKED if one presses a key the display shows for a few instants the HOLD F1 TO UNLOCK message To unlock the keyboard press again at length the F1 key the display shows the unLoCk message for a few instants NOTE It s possible to lock all keys individually in a permanen
48. e whose external dimensions are shown in figure 4 The instrument may be installed on the wall NOTE If the identification plate is supplied separately therefore not attached to the indicator it is advisable to attach it to the indicator in order to be able to identify the instrument 207 O O Q O O 538 Figure 4 Measurements and dimensions in mm 1 2 Available for load cells serial lines inputs outputs 3 Power supply input 4 RJ45 connector 3590EKR 3590EXP 3590EXT CPWE CPWET series indicator E AF02 02 12 05 EN U 3 4 CPWETD CASE AND DIMENSIONS The weight indicator has a STAINLESS STEEL case whose external dimensions are shown in figure 5 The instrument may be installed on the wall NOTE If the identification plate is supplied separately therefore not attached to the indicator it is advisable to attach it to the indicator in order to be able to identify the instrument 207 Figure 5 Measurements and dimensions in mm 1 2 Available for load cells serial lines inputs outputs 3 Power supply input 4 RJ45 connector 3590EKR 3590EXP 3590EXT CPWE CPWET series indicator E AF02 02 12 05 EN U 3 5 POWER SUPPLY 3590E indicator is powered with 12Vdc voltage 8 24 Vdc in the version through an internal adapter which converts the 100 240Vac 50 60Hz mains voltage and 6 from the battery fitted depending on the model TO P
49. e battery before the system is switched off for the last time 2 recharge completely every 3 months Do not pour liquids on the weight indicator Do not use solvents to clean the weight indicator Do not expose the instrument to direct sunlight nor place it near heat sources Place or anchor the weight indicator and platform on a non vibrating base All the connections of the indicator have to be made respecting the rules applicable in the zone and in the installing environment Everything not expressly described in this manual has to be considered as improper use of the equipment Read carefully and apply what is described in section 3 Do not install in any area where there is a risk of explosion collection or to the reseller when a new equivalent type of equipment is purchased The adequate differentiated refuse collection in having the product recycled helps to avoid possible negative effects on the environment and health and supports the recycling of the materials of which the equipment is made The unlawful disposal of the The crossed out wheeled bin on the product means that the product end of life it must be taken to separate product by the user will entail fines foreseen by the current regulations 3590EKR 3590EXP 3590 CPWE CPWET series indicator E AF02 02 12 05 EN U 2 MAIN TECHNICAL SPECIFICATIONS 3590E 12 Vdc 8 24 Vdc in the IO versions with internal 100 240 Vac 50760 Hz 112 Vdc ada
50. e is one on the plate and press TARE to zero the display b Press 2ndF and F7 key in sequence the display shows the message ENTRY OF APW in the first line while the second line shows the previous value of the APW and its unit of measure With the keyboard enter the new value of the A P W NOTE the indication of the previous A P W remains until one saves c Proceed with the operations as in the counting with reference One can exit the counting and view the weight at any time by pressing in sequence the 2nd F and F8 keys the display alternates in this order the visualisation of the pieces gross weight and net weight NOTES The reference is lost each time that the indicator is turned off In any case it is possible to link the calculated A P W to a stored article see section 11 1 8 and by selecting the article it will automatically be enabled each time the instrument is turned on together with the linked A P W To cancel the active reference press the C key the pressing of the C key will cause also the cancellation of the active fare One can enter the known APW with the 2ndF and F7 keys also after having loaded the pieces on the scale If there is a tare it is necessary to subtract its value already known entering it through one of the tare functions described in section f 13 1 5 COUNTING IN EXTRACTION a Putthe loaded container onto the platform zero with TARE b With F7 one selects a reference quantity
51. election of scale 1 2 Selection of scale 2 3 Selection of scale 3 4 Selection ofscale4 In case of APPROVED instrument and active tare the gross weight will show for about 5 seconds then return to the net weight visualization 16 3590EKR 3590EXP 3590EXT CPWE CPWET series indicator E AF02 02 12 05 EN U 4 1 2 ENTERING ALPHANUMERIC TEXT It might be necessary while the weighing system is working to enter some alphanumerical texts such as descriptions alphanumerical messages operator lot number customer etc To enter the characters one uses the 0 to 9 keys By pressing one of these keys a few times the characters shown on the key and other special characters will be shown on the display initially the first letter in the bottom left will appear and then the other characters towards the right After digiting a character the blinking cursor after a few instants advances automatically of a position Function of the keys switches the writing mode from numeric nuM to characters ChAr In the nuM mode one enters just the numbers while in the ChAr mode one can enter all the characters of If pressed for an instant it cancels the written characters first the characters that follow the cursor are cancelled then those that precede it one at a time If pressed at length it deletes all entered characters With empty text it exits the entry phase without confirming SHIFT It enters a space in the mid
52. er storage or press C to return to the weighing phase NOD 11 1 3 CANCELLATION 1 Press the F1 key to enter in the article database 2 Select the storage to be deleted by using the arrow keys 4 by typing type the storage number with the keyboard the LCD display shows the first corresponding DESCRIPTION line by searching the first description see section 11 1 9 3 Press F3 4 Theindicator requests a further confirmation press ENTER to confirm or another key to cancel 5 Restart from point 2 or press the C key to return to weighing 11 1 4 PRINTING 1 Press the F1 key to enter in the article database 2 inside the article database menu press the F5 key The display shows the message PRINT confirm with the ENTER key to print the entire article database which shows all the relative fields for each stored article 11 1 5 SELECTION DESELECTION With no memory storage selected the LCD display shows in the data section see 4 2 section To select a stored article one can proceed in two ways 1 Type memory storage number and press F1 2 Pressthe F1 key to access database select the memory storage by using the arrow keys 4 by typing the storage number with the keyboard the LCD display shows the first corresponding DESCRIPTION line by searching the first description see section 11 1 9 3 Press ENTER to activate the article To deselect a selected
53. ered ape and ENABLING for each configured output The display shows S 1 on relay 1 ENABLING SETPOINT press ENTER enter the weight value with the keyboard and confirm with ENTER use the C key to quickly zero the current value The display shows S 1 oFF relay 1 DISABLING SETPOINT press ENTER enter the weight value with the keyboard and confirm with ENTER use the C key to quickly zero the current value Proceed in the same way for the following outputs if present When finished programming the setpoints exit with the C key OUT1 STATUS ENABLED DISABLED S1 OFF 510 GROSS WEIGHT 48 3590EKR 3590EXP 3590EXT CPWE CPWET series indicator E AF02 02 12 05 EN U Functioning without hysteresis rL iSt HYSTERESIS parameter set as iSt oFF The operating mode is the same as the previous one except that just one SETPOINT is entered for each output S 1 for this purpose the access to the S 1 oFF parameter is inhibited NOTES the outputs have the NONE none functioning mode the enabling of the 202 function has no effect The DISABLING SETPOINT must be less or equal to the ENABLING ones if a value greater than the ENABLING one is entered and confirmed in the DISABLING SETPOINT the indicator will set at 0 the setpoint until a correct value is entered If a value lower than the DISABLING one is entered and confirmed in the ENABLING SETPOINT that value is accepted but the DISABLING SETPOINT
54. gt gt StEP TECH MAN REF while the instrument carries out a series of checking and preheating self tests E AF02 XX name of the installed software in which XX identifies the software language XX YY is the software version installed EXECUTION AUTOZERO The instrument carries out the autozero at start up function if a weight is detected within the percentile set in the lt lt Auto 0 gt gt step it is cleared if the weight is not within this tolerance With a non approved instrument the display shows the weight after a few instants with an approved instrument the message EXECUTION AUTOZERO appears continuously on the display until the weight is within tolerance The auto zero function at start up may be disabled in the set up environment only with non approved instrument see SEtuP gt gt ConFiG gt gt PArAm gt gt Auto 0 TECH MAN REF By pressing the 2ndF key for an instant while the version is shown in the display the indicator will show in this order 01 01 in which 01 indicates the instrument type 01 indicates the metrological software version XX YY ZZ 5 the installed software version HH is the installed hardware version 08 LEGAL FOR TRADE or HIGH RESOLUTION if the instrument is APPROVED or UNAPPROVED respectively 9 is the g gravity value only with APPROVED instrument 3 7 TURNING OFF THE INSTRUMENT TO TURN OFF the 3590E CPWET or TO RESTART the CPWE keep t
55. he scale is in the counting phase or the description of the article if selected e The nr of the scale in use and the eventually stored TARE on the second line Therefore it s possible to execute the reference on the present scale switch to the counting scale and execute the desired counting the reference is active on all the connected scales 40 3590EKR 3590EXP 3590EXT CPWE CPWET series indicator E AF02 02 12 05 EN U 13 2 WEIGHT AND QUANTITY TOTALISATION FUNCTIONS The programme has been made to manage the accumulation and the printing of the weight and quantity The totalisation takes place in the ways selectable in the technical set up described in the following section The totalised weight and quantity are automatically accumulated in the instrument totals PARTIAL GENERAL GRAND TOTAL and the weighs progressives are automatically increased relative to the previously shown totals Furthermore if an article has been enabled the instrument increases both the totals as well as the weighs progressive relative to the selected article The data that is increased is WEIGH NUMBER PIECES TOTAL GROSS WEIGHT TOTAL NET WEIGHT TOTAL TARE TOTAL 13 2 1 TOTALISATION MODES The indicator allows accumulating the weight on the scale in different modes e Totalisation in loading e otalisation in unloading e Totalisation both in loading as well as in unloading The setting of the totalisation is made in the set up en
56. he C key pressed until the OFF message appears on the LED display and POWER OFF on the LCD display TO TURN OFF the CPWE remove the instrument s power supply 13 3590EKR 3590EXP 3590 CPWE CPWET series indicator E AF02 02 12 05 EN U 3 8 TURNING ON PRINTER IN ENERGY SAVING MODE Premise the SEtuP gt gt SEriAL gt gt CoMPrn gt gt PWrPrn parameter must be set as EXt oFF or PWrint TECH MAN REF system where the indicator is connected to a printer and both are battery powered the printer is normally maintained in STAND BY and powered only when a printout is needed This function reduces the energy absorbed by the battery when the printer is not being used If in this configuration one should power the printer to change the paper and other maintenance jobs one needs to press in sequence the ENTER and 0 keys during the weighing the display shows Prn on and the printer is kept on Press any key to exit from this condition 4 FRONT PANEL KEYS AND DISPLAYS 3590E gt D 0 m C lt Le ra Fo KW T n HELP 3590EKR 3590EXP 3590 CPWE CPWET series indicator E AF02 02 12 05 EN U CPWET ra ES gt FQ Fn SHIFT 4 1 FUNCTION OF THE KEYS In the following section and later on in the manual the keys functioning is described in accordance to how these are configured by the factory It is possible
57. he NET TOTAL WEIGHT are printed PRINTING OF THE DATABASE REPORT Fixed printout By pressing the F5 key inside the databases it is possible to print a report of the ARTICLE DATABASE CUSTOMER DATABASE or TARE DATABASE see sections 11 1 4 11 2 4 7 4 4 N B These printouts are not modifiable The printing made with the F5 key must be recalled within each single database 14 1 LINKING OF THE FORMATS TO THE PRINT FUNCTIONS Through function 200 combinable with the desired key lt lt F KEYS gt gt step TECH MAN REF one accesses the linking of the print formats configurable in the SEtuP gt gt SEriAL gt gt Prn FMt step TECH MAN REF to the 9 programmable print functions Print function Linked format 200 gt 01 gt 01 1 F7 _ u ENTER F6 SF 08 a 45 3590EKR 3590EXP 3590EXT CPWE CPWET series indicator E AF02 02 12 05 EN U Print function Linked step SIMPLE PRINTOUT PB PRINTING OF THE TOTALISED WEIGHT TOTALISATION F6 SF 001 SF 02 PRINTING THE PARTIAL TOTAL F8 or automatic entry SF 03 PRINTING THE GENERAL TOTAL PB SF 04 PRINTING THE GRAND TOTAL FPO SF 05 HEADING OF THE FIRST TOTALISATION F6 SF 06 Function 306 combinable TOTAL OF EACH HANDLED ARTICLE with the desired key recalls various
58. he operation described in the previous sections 11 2 8 HELP By pressing the HELP key it s possible to see the keys list used in the menu The key list is automatically If you want to see the keys list in manual mode use the arrow key F6 and F7 4 38 3590EKR 3590EXP 3590EXT CPWE CPWET series indicator E AF02 02 12 05 EN U 12 DATABASE ACCESS PASSWORD In the SETUP Mode dtb PWd parameter TECH MAN REF one can set a password for access to the databases password will be required only when one wants to insert modify or delete an element of the file for a moment the display shows the message USER PRESS KEY afterwards it will be no longer possible to make changes to the database To access the complete menu Press any key DURING THE VISUALISATION OF THE USER PRESS KEY the instrument requests the entry of the password a number will appear e Enter the password and confirm with ENTER e f one does not know the password one should give the random number to the manufacturer who will give a password valid ONLY FOR THAT RANDOM NUMBER 13 COUNTING AND TOTALISATION PROCEDURES Besides the basic standard weighing functions this software version allows to execute a weight count of the pieces with totalisation and eventual linking of one of the 1000 previously programmed articles 13 1 COUNTING FUNCTION 13 1 1 COUNTING IN LOADING WITH ENTRY OF THE REFERENCE UNIT a Load the empty container on the platform
59. he reference quantity weight can not be lower than the percentage set in the F ModE gt gt Count parameter TECH MAN REF If this is so the sample quantity put on the plate is accepted and the APW is calculated and shown on the display Otherwise the procedure is blocked and the operation must be repeated with an always greater sample quantity and therefore heavier 13 1 3 OPTIMISATION OF THE APW After having carried out the REFERENCE operations section 13 1 1 if one adds to the reference quantity another amount of pieces as long as it is on the scale and greater than one the instrument automatically updates the A P W the display shows for an instant the message SAMPLE to indicate the execution By repeating the operation various times one has the most accurate A P W before starting to count the large quantities While programming the general SET UP see F MoDE gt gt P M u parameter TECH MAN REF one can choose to update the APW automatically upon weight stability or manually through the 303 function combinable with the desired key lt lt F KEYS gt gt step TECH MAN REF In any case the update is executed after having added to the reference quantity another amount of pieces which is greater than zero but lower than the one on the scale 39 3590EKR 3590EXP 3590EXT CPWE CPWET series indicator E AF02 02 12 05 EN U 13 1 4 COUNTING WITH THE ENTRY OF THE KNOWN A P W a Load the empty container if ther
60. i IM Ic EE 29 TA SEMIAUTONMATIG m 29 B pino TARE 29 CALCULATED MANUAL o Eb RE A pau BI S RN TUN UE na ee LUI E 29 TARE DATABASE Sse 30 ea e e SE O O a 30 EU Z2 NMODIEIOATION cami SR O DOR a eaten OM RU T DIR UE 30 143 CANCELLATION Pan x edet tia a Sedes tdi esum tpa ttn fece ent debes ESR PORUM 30 E 31 49 SELECTION DESELEG HON a espe UE 31 TAO BELE e 31 TARE CANCELLATION Eee na E iata Mes rum a 31 FOCOCKEDIUNLOGKED TARE ssa dass dadmi n t e mim hd em a 31 7 7 LIMITATION THE TARE FUNCTIONS AGER sss 31 7 8 LINKING OF A PRESET TARE WITH AN ARTICLE IN THE DATABASE snnm 31 DISABEINGIOE TEIE TARE N cR HIS M 32 7 10 AUTOMATIC TARE AFTER THE 32 7 11 FIRST TARE OPERATION IN FORMULATION OR DOSAGE SYSTEMS nennen 32 7 12 RESTORING TARE AND ZERO AT THE 32 8 MULTIRANGE AND MULTIDIVISION FUNCTION nennen nnne ntn nnn 32 9 DISPLAY OF METRIC DATA MFO ba dex E
61. ies indicator E AF02 02 12 05 EN U 4 2 5 DISPLAYED DATA 3590E The data is displayed on two lines by pressing in sequence the 2nd F and F9 keys one scrolls in order the following visualisations VISUALISATION WITH SELECTED ARTICLE WITHOUT SELECTED ARTICLE First article description or net gross weight ARTICLE TEST NET 2 00 kg Active scale and active semiautomatic tare PT B1 TARE 0 00 kg B1 TARE 0 00 kg if manual tare Average piece weight APW 114 09719 APW 114 09719 Active scale and active semiautomatic tare PT B1 TARE 0 00 kg B1 TARE 0 00 kg if manual tare NOTE this visualisation is available in counting visualisation of the pieces on the display Total article weighs or weighs general total Active scale and active semiautomatic tare PT if manual tare Article total quantity of pieces or article total weigs if a reference has not been executed QTY TOT QTY TOT Active scale and active semiautomatic tare PT B1 TARE 0 00 kg B1 TARE 0 00 kg if manual tare First customer description CUSTOMER TEST CUSTOMER TEST Active scale and active semiautomatic tare PT B4 TARE 0 00 kg B1 TARE 0 00 kg if manual tare NOTE with an active customer By proceeding with the pressing in sequence of the 2nd F and F9 keys the same visualisations will show up again with the 1s tare in the second line VISUALISATION WITH SELECTED ARTICLE WITHOUT SELECTED ARTICLE First article descr
62. if it exists and press TARE to zero the display b Press F7 the scale is ready for the REFERENCE Type the desired digit with the numeric keyboard put the same number of pieces on the platform and press ENTER c If the sample weight is accepted see Sample minimum weight the display will show the calculated Average Piece Weight and the tare weight The PCS led turns on d Load onto the platform the number of pieces the calculated value will appear on the display e Unload the platform the A P W remains in storage and allows to carry out a new count of pieces of the same type without repeating the REFERENCE operation In this case before each count make sure that the display shows PCS 0 otherwise zero with the TARE key One can exit the counting and view the weight at any time by pressing in sequence the 2ndF and F8 keys the display alternates in this order the visualisation of the pieces gross weight and net weight NOTES The reference is lost each time that the indicator has been turned off In any case it is possible to link the calculated A P W to a stored article see section 11 1 8 and by selecting the article it will automatically be enabled each time the instrument is turned on together with the linked A P W To cancel the active reference press the C key this will provoke also the cancellation of the active tare 13 1 2 MINIMUM SAMPLE WEIGHT In order to ensure the maximum accuracy of the APW t
63. ighs or the weights transmitted to the PC to the printers and to all the non approved devices The stored values can then be recalled by the PC serial line or directly on the display for a following check The data filed with each weigh or upon each weight transmission is Gross weight Tare Unit of measure Number of selected scale The memorisation of a weigh takes place e Following the reception of a command through the serial line See section 16 2 1 e Upon the printing made with the F5 key or upon totalisation By setting the SEtuP gt gt SEriAL gt gt CoMPrn gt gt ProtoC parameter on Alibi TECH MAN REF possible also to transmit the string weigh ID on the PC port by setting the SEtuP gt gt SEriAL gt gt CoMPC gt gt ProtoC parameter on Alibi TECH MAN REF The string is transmitted in the same format of the string received in response to the WEIGHT VALUE REQUEST WITH WEIGH ID command described in section 16 2 1 The identification of the weigh takes place through the ID code a code is given to each weigh allowing to find the weigh in the database If the weight can be saved in the alibi the numeric ID will be substituted with the message NO The ID has the following format du number gt Weigh number gt Rewriting number number of 5 digits which may go from 0 to 00255 it indicates the number of complete rewritings of the alibi memory Weigh number number of 6 digits which may go from
64. iption or net gross weight Active scale and 1st tare value PT if manual tare Average piece weight APW 114 0971 g APW 114 0971 g Active scale 1 tare value PT if manual B1 1 T 0 00 kg 0 00 tare tare Article total quantity of pieces or article total weigs if a reference has not been executed Active scale and active semiautomatic tare PT if manual tare First customer description Active scale and 1st tare value PT if manual tare Total article weighs or weighs general total 7 Active scale and 1st tare value PT if manual NOTE this visualisation is available with an active customer By linking the function to a direct key see the lt lt F KEYS gt gt step it is possible to quickly recall a visualisation by digiting with the numeric keyboard the relative number and pressing the key linked to the function 24 3590EKR 3590EXP 3590 CPWE CPWET series indicator E AF02 02 12 05 EN U Furthermore by linking the number of a specific visualization to the function preamble function in the lt lt F KEYS gt gt step it is possible to select it directly with a direct key for example F1 key to select the visualization n 1 and F2 key to select the visualization n 2 NOTES Default Visualisation 0 If the ZOOM function is always active these visualizations are not be displayed If the EEEEE message appears this means that the value exceeds the maximum number
65. is put at 0 The 0 value is valid on both the setpoint values The SETPOINT check on the weight is active just during the weighing in other words not during the modification of the SETPOINTS In case of non valid weight local or from remote scale all the outputs are disabled 15 4 1 2 SETPOINT ON THE NET WEIGHT By selecting this functioning mode the output function on the NET weight is enabled the entry of the SETPOINTS and the specifications are the same as the functioning mode on the gross weight 15 4 1 3 GROSS WEIGHT AT ZERO By selecting this functioning mode the output function on the GROSS weight at 0 is enabled 15 4 1 4 NET WEIGHT AT ZERO By selecting this functioning mode the output function on the NET weight at 0 is enabled 15 4 1 5 INSTABILITY By selecting this functioning mode the output function on the unstable weight is enabled 15 4 1 6 TOTALISATION By selecting this functioning mode the output function is enabled when the totalisation has taken place the output remains enabled until the totalisation is restored in other words by the passing by zero of the net weight or by weight instability see F ModE gt gt rEACt REACTIVATIONS parameter of the TECHNICAL SET UP TECH MAN REF 15 4 1 7 SETPOINT ON THE PARTIAL TOTAL By selecting this functioning mode the output function on the sum between the NET weight present on the scale and the accumulated net partial total is enabled the entry of the SETPOINTS and the spe
66. isplay shows its value With the arrow keys 4 select the available tares and press ENTER to confirm by pressing instead the C key one passes to the following setting by cancelling the linkage to the tare e SETPOINT 1 value in pieces of the first set point e SETPOINT 2 value in pieces of the second set point e SETPOINT 3 value in pieces of the third set point e LINKED CUSTOMER linking of a CUSTOMER IN THE DATABASE the display shows the customer number in the database from 0 to 99 while the display shows its value select the customer with the arrow keys w and press ENTER to confirm by pressing instead the C key one passes to the following configuration cancelling the linking to the customer 9 Restart from point 2 or Press the C key to return to weighing 34 3590EKR 3590EXP 3590EXT CPWE CPWET series indicator E AF02 02 12 05 EN U 11 1 2 MODIFICATION 1 Press the F1 key to enter in the article database 2 Select the storage to be modified by using the arrow keys 4 or by typing the storage number with the keyboard the LCD display shows the first corresponding DESCRIPTION line by searching the first description see section 11 1 9 Press F2 select the field to be modified by using the arrows keys and press ENTER Modify the value and press ENTER to confirm Restart from point 4 to modify other fields or press C to return to the list of storages Restart from point 2 to modify oth
67. nected to the Com Aux serial line 1 gt gt Selection of scale number 1 2 Selection of scale number 2 3 gt gt Selection of scale number 3 4 Selection of scale number 4 For example with 2ndF and the 1 key on the display the message scale 1 will appear for a few instants and then the value of the Weight on the selected scale In case of various connected scales the selected scale is shown on the display of the instrument 3590E Selected scale B1 scale 1 B2 scale2 scale 3 B4 scale 4 remote CPWE Selected scale B1 scale 1 B2 7scale2 B3 scale 3 B4 scale 4 B0 remote 1 scale 1 2 scale 2 3 scale3 4 scale 4 R remote 5 1 FUNCTIONING WITH REMOTE SCALE PREMISE the functioning of the remote scale is foreseen with the use of independent channels tYPE step TECH MAN REF The remote scale transmits in a continuous mode the weight string on a dedicated serial port optional in a unidirectional way from scale to indicator It is possible to use the serial ports on the indicator s motherboard simultaneously with the use of the remote scale In the normal scale status press the 2ndF and 0 keys to pass to the display of the weight on the remote scale If just the remote scale is connected after the start up phase the indicator positions itself directly on it If the remote scale allows this it is possible to carry out the ZERO and TARE operations directly from the indi
68. of measure Press C to exit the reading state of the weighs NOTE It is possible to read the weigh carried out also through the PC serial line see the WEIGH READING serial command in the following section 16 2 SERIAL COMMANDS FOR MANAGING THE ALIBI MEMORY I IMPORTANT If the serial commands are transmitted in the format lt ESC gt command lt STX gt in which lt ESC gt is the ASCII decimal 27 character lt STX gt is the ASCII decimal 02 character Also the relative answer will be lt ESC gt string lt STX gt 16 2 1 REQUEST WEIGHT VALUE WITH WEIGH ID The command which allows saving the weight in the alibi memory and the transmission is lt II gt PID lt CRLF gt lt Il gt machine code only if functioning in 485 PID saving command of the weight data in the alibi memory CR ASCII 13 decimal code LF ASCII 10 decimal code If the gross weight is equal or greater than zero and stable the instrument will save the weight on the belt in the alibi memory And the PID string weight id will be transmitted on the PC port this is described in the following section 53 3590EKR 3590EXP 3590EXT CPWE CPWET series indicator E AF02 02 12 05 EN U 16 2 2 STRING FORMAT WEIGHT ID The PID string contains all the information regarding the executed weigh DESCRIPTION OF THE PID STRING lt ESCo IIJPIDSS B LLLLLLLLLLUU YYTTTTTTTTTTUU ID NO CR or CRLF gt in which 11 485 address only
69. on 200 preamble function in the lt lt F KEYS gt gt step TECH MAN REF it is possible to access directly to the modification of it with a direct key for example F1 key to quickly link the S F 1 and F2 key to quickly link the S F 2 Furthermore for some print functions the desired formats can be quickly linked by setting directly the corresponding code function to the desired key lt lt F KEYS gt gt step TECH MAN REF without having to program the preamble CODE QUICK LINKING FUNCTION PRINT FUNCTION Format linking to the Simple Printout Prn Fmt SF 01 Format Linking to the Totalisation SND FMT SF 02 46 3590EKR 3590EXP 3590 CPWE CPWET series indicator E AF02 02 12 05 EN U TO QUICK LINK THE FORMAT e Recall the desired print function by pressing the linked key lt lt F KEYS gt gt step TECH MAN REF e The display shows XX in which XX indicates the number of the format to be linked e the format number and press ENTER NOTE In order to not link any format to a print function one should enter the number 00 14 2 FORMATTING HEADING PRINTOUT If a format is linked to the FIRST TOTALISATION HEADING pressing of F6 upon the first totalization will cause the printing of this format and then the format linked to the totalisation function The data which will be configured allowing to create an independent print format which will be printed as a heading to the first totalisa
70. ovide for any compensation for losses or damages direct or indirect incurred by the Customer due to complete or partial failure of instruments or systems sold even during the warranty period AUTHORISED SERVICE CENTRE STAMP 57
71. ows the first corresponding DESCRIPTION line 3 Press F2 4 Select the field to be modified by using the arrow keys and press ENTER 5 Modify the value and press ENTER to confirm 6 Press C return to the list of storages 7 Restart from point 2 to modify other storage or press C to return to the weighing phase 7 4 3 CANCELLATION 1 Press the Fn key followed by the TARE key to enter in the tare database 2 Select the storage to be deleted by using the arrow keys 4 by typing the storage number with the keyboard the display shows the first corresponding DESCRIPTION line 3 Press F3 4 The indicator requests a further confirmation press ENTER to confirm or another key to cancel 5 Restart from point 2 or Press C to return to the weighing phase 30 3590EKR 3590EXP 3590EXT CPWE CPWET series indicator E AF02 02 12 05 EN U 7 4 4 PRINTING 1 Press the Fn key followed by the TARE key to enter in the tare database 2 Once inside the article database menu press the F5 key The display shows the PRINT text confirm with the ENTER key to print the list of the stored tare values referred to the selected scale 7 4 5 SELECTION DESELECTION To select a stored tare during the standard weighing operations one can proceed in two ways 1 Digit the storage number of the tare using the numeric keyboard and recall the 306 function combinable with the desired key lt lt F KEYS gt gt step TECH MAN REF If a tare
72. pter 6 Vdc from rechargeable built in battery fitted depending on the model CPWE POWER SUPPLY 8 24 Vde 6 Vdc from external rechargeable battery upon request CPWET 12 Vdc with external 100 240 Vac 50 60 Hz 12 adapter 6 from external rechargeable battery upon request 0 3 uV approved instrument 0 03 uV non approved instrument Only in gross mode programmable at 1 2 divisions Configurable up to 5096 of max load capacity Configurable up to 5090 of max load capacity 5Vdc 596 120mA max 8 350 Ohm cells 6 wires with Remote Sense 10000e x 3000e for legal for trade weighing expandable up to 800 000 for internal use with minimum signal coming from the 1 6 mV V cell 3590E Red high luminosity LED indicators with six digits h 13 mm dio Back lit graphic 160x32 dot LCD CPWE Back lit graphic 160x32 dot LCD Database of 1000 articles 3 lines of description of 20 characters DATABASE MEMORY Database of 300 preset tares Database of 200 customers 5 lines of 30 characters 3590E 16 status LEDs Graphic icons on LCD display CPWE Graphic icons on LCD display CPWET 3 way control light Graphic icons on LCD display Impermeable polycarbonate keyboard IP65 protection degree with membrane keys with audible and tactile feedback Calibration and linearity up to 8 points fully digital and programmable from the keyboard or from with Dinitools 2 in
73. put on a table or fixed to a shelf or column available on request NOTE If the identification plate is supplied separately therefore not attached to the indicator it is advisable to attach it to the indicator in order to be able to identify the instrument M9 6 000 eo O Figure 2 Measurements and dimensions in mm 1 RJ45 connector 2 Fixing for shelf or column mounting 3 5 Available for load cells serial lines inputs outputs 4 Power supply input 3590EKR 3590EXP 3590EXT CPWE CPWET series indicator E AF02 02 12 05 EN U STAINLESS STEEL MODEL The indicator has a STAINLESS STEEL case whose external dimensions are shown in the Figure 3 It can be simply put on a table or fixed to a shelf or column available on request NOTE If the identification plate is supplied separately therefore not attached to the indicator it is advisable to attach it to the indicator in order to be able to identify the instrument 264 Figure 3 Measurements and dimensions in mm 1 RJ45 connector 2 Fixing for shelf or column mounting 3 Available for load cells serial lines inputs outputs 4 Power supply input 3590EKR 3590EXP 3590EXT CPWE CPWET series indicator E AF02 02 12 05 EN U 3 3 CPWET CASE AND DIMENSIONS The weight indicator has a STAINLESS STEEL cas
74. put output RS232 ports on terminal board amp connector Management of PC keyboard or barcode reader 3590EXP 3590EXT and CPWET 2 optoisolated inputs optoisolated photo couplers 12Vdc 24 20mA max 4 outputs optoisolated photomosfets 48Vac 0 15A 60Vdc 0 15A 10 max 3590EXT in version and CPWE 8 inputs optoisolated photo couplers 12Vdc 24Vdc 20mA max 16 outputs optoisolated photomosfets 48Vac 0 15A 60Vdc 0 15 16 bit analogue output configurable from keyboard full scale value zero scale value and minimum value from 0 to 10 or from 0 to 20mA the maximum resistance applicable on the output current is 350 Ohm and the minimum resistance applicable on the output voltage is 10 kohm INPUTS AND OUTPUTS ANALOGUE OUTPUT Option available on the 3590EXT IO version and CPWE version 3590EKR 3590EXP 3590 CPWE CPWET series indicator E AF02 02 12 05 EN U 2 1 ACCESSORIES AVAILABLE On the indicator it s possible to implement internal and external modules used to increase interfacing possibilities For example the number of usable outputs various types of printers in order to have a report of the weighs made or giant display in order to better see the weigh operations Also one can connect a PC in order to simply program the instrument through Dinitools or in order to have a complete management of the weighs Contact the reseller for the list of the av
75. reases the blinking digit It allows scrolling backwards in the menu steps or in the parameters within a step If pressed for an instant it executes the printing and the zeroing of the partial total In the numeric or alphanumeric input phase it selects the digit to be modified from right to left If pressed for an instant it executes the printing and the zeroing of the general total In the numeric or alphanumeric input phase it selects the digit to be modified from left to right If pressed for an instant it executes the printing and the zeroing of the large total n the numeric or alphanumeric input phase it enters a space between two characters n the article database if pressed for an instand it allows to update APW NUMERIC Entry of digits or characters KEYBOARD While weighing these enter a numeric value with which it s possible to execute calculations see section 15 1 CALCULATOR 4 1 1 2ndF KEY SECOND FUNCTION OF THE KEYS In the weighing phase by pressing the 2ndF key together with another key its possible to execute various functions continue reading the manual for the details of the functions 2nd F1 Print Clearing of Total of each handled Article F8 J Net Gross Conversion Modification of what is viewed on the display Causes the display of the present metric scale information see section 9 0 J Selection of remote scale 1 S
76. recalling one of the clearing functions the instrument requests a confirmation before proceeding with the cancellation press ENTER to clear C for continuing to accumulate possible to disable the confirmation request in the F ModE gt gt totAL gt gt rESEt step TECH MAN REF In case of visualisation of the total the instrument automatically exits the function after a few seconds NOTES The clearing of the weight total causes also the reset of the relative number of weighs The weight data of the cleared total will be updated only with the subsequent totalisation he ARTICLE TOTAL is article specific in other words there is a total for EACH ARTICLE USED The other totals are GENERIC and can be cleared INDEPENDENTLY ONE FROM THE OTHER i e if one clears the Grand total with the following totalisation the other totals will continue to increment while the Grand total will restart from 0 13 2 9 CLEARING AND AUTOMATIC PRINTING OF THE PARTIAL TOTAL AFTER N WEIGHS Through function 400 combinable with the desired key lt lt F KEYS gt gt step TECH MAN REF it s possible to set whether to clear and print the partial total manually or automatically The automatic printing and clearing function allows to automatically clear the partial total after the scale has carried out a number of consecutive totalisations both in and out of tolerance configurable through function 401 combinable with the desired key lt lt F
77. s a Dom REL Cr 19 ALT Wel SECOND FUNCTION OF THE KEY panes tona tinum artt autein 16 21 2 ENTERING ALPHANUMERIC ET ciue GNU Und 17 4 1 9 DISABLING THE KEYBOARD eek contin bem tex ecran dul bn Pace tete ASRS 17 UPN es Ltr MENO rosas don dta utter etu etae a cee 18 T LS INDICATOR CONNECTED IO PC NETBORBRD 3 cii LU RATE DATO Dna SEA UE 18 4 1 5 1 DIRECT COMPILATION OF INPUT TEXT teur o RE rato o 19 ONTO m nm 19 T9 EY INFRARED REMOTE CONTROL ae 19 4 1 6 2 0 KEY RADIO REMOTE CONTROL metr vun 20 FUNCG HON DI INS aec C 21 4 2 TANEIGAT ZOOM TEM 21 4 2 2 STATUS INDICATOR Suinn ena eases Snes 22 42 9 BATTER Y LEVELINDICA TON erent enn ce terete te mre cre rere err Se 23 AULT amines aaa Dd UI RAND MENDA MU nna 23 4 20 DISPEAYED DATA ahahaha tata 24 D2 O GALE SELECTION e ID TIME MED MEL 28 ox PUNGTIONINGATTEUREMOTE SCALE esos MOD M MERE REE 28 o6 SCALE ZERO FUNGTION itia eta cer E Y bra brc usen ete t a Pn nha ea a 29 O FOYOLICALAUTOMATIC ZERO citet iita e Re UT Ce DA pue Rn E OR 29 E FUNG ONS eiim nd t us
78. s or weighs general total Active scale and 1 tare value if manual tare Average piece weight Active scale and 1 tare value if manual tare First customer description Active scale and 1 tare value T if manual tare Total quantity of pieces or article total weigs if a reference has not been executed Active scale and 1 tare value if manual tare NOTE this visualisation is available with an active customer Furthermore by linking the number of a specific visualization to the function preamble function in the lt lt F KEYS gt gt step it is possible to select it directly with a direct key for example F1 key to select the visualization n 1 and F2 key to select the visualization n 2 NOTES Default Visualisation 0 If the EEEEE message appears this means that the value exceeds the maximum number of digits shown by the instrument VISUALISATION WITH ACTIVE WEIGHT ZOOM The data is shown on one line under the weight Pieces section Through function 208 combinable with the desired key lt lt F KEYS gt gt step TECH MAN REF one scrolls in order the following visualisations NUM VISUALISATION WITH SELECTED ARTICLE WITHOUT SELECTED ARTICLE Em e 26 3590EKR 3590EXP 3590 CPWE CPWET series indicator E AF02 02 12 05 EN U First article description or net gross weight ES WEIGH 00000000 Average piece weight APW
79. s possible to quickly lock unlock the tare DISPLAY MEANING LoCK LOCKED TARE unLoCK UNLOCKED TARE The setting of the tare may be made also in the TARE LOCK UNLOCK SEtuP gt gt t LocK parameter of the TECHNICAL SETUP TECH MAN REF 7 7 LIMITATION OF THE TARE FUNCTIONS For specific requirements it is possible to limit the tare functions with approved instrument by setting YES in the SEtuP gt gt d SALE step of the SET UP environment TECH MAN REF the SEMIAUTOMATIC TARE can not be modified with a manual or calculated tare or one from database the manual or calculated tare or one from database must be entered or modified only with UNLOADED scale With approved instrument the SEtuP gt gt d SALE step is not displayed Read only 7 8 LINKING OF A PRESET TARE WITH AN ARTICLE IN THE DATABASE It is possible to link a known tare value stored in the tare database to each article in the database this value will be enabled With each selection of the article 31 3590EKR 3590EXP 3590EXT CPWE CPWET series indicator E AF02 02 12 05 EN U See section 11 1 for further details 7 9 EXECUTION MODE DISABLING OF THE TARE possible to select the tare execution mode through the setting of the F ModE gt gt totAL gt gt tArE step TECH MAN REF By setting diSAbL one disables all the tare operations By setting EnAbLE one enables all the tare operations described previously By setting MAnd the tare mus
80. sible to switch from the capital letters to the lower case letters and vice versa or enter the second character keys SHIFT and 0 CAPS LOCK corresponding to the key for example 96 Cursor keys Scroll the parameters ay Increase or decrease the blinking digit while entering a value When entering a value or an alphanumeric string it scrolls the digits to the right or to the left F1 F2 F10 F1 F2 F10 keys NOTE through the remote keyboard it s not possible to carry out the functions made by pressing the keys at length Numeric and alphanumeric 3590EKR 3590EXP 3590 CPWE CPWET series indicator E AF02 02 12 05 EN U 4 1 5 1 DIRECT COMPILATION OF INPUT TEXT By entering an alphanumeric text through an external keyboard the instrument goes into insertion mode by pressing a function key from F1 to F9 programmed with a direct function to fill in an input text 121 up to 130 the edited alphanumeric text is assigned to the corresponding input text The alphanumeric display contains up to 32 characters 4 1 6 REMOTE CONTROL Depending on the indicator model it is possible to remotely control the instrument through one of the following types of remote controls 19 key infrared ir or 6 key radio rd The type of remote control to be used must be selected in the Setup environment in the lt lt inF Red gt gt step TECH MAN REF NOTE The infrared remote controls are for indoor use only
81. sing the TARE key one tares any weight which is on the scale the display shows tArE for an instant and then 0 net weight the NET and gt T or iil indicators turn on the display shows furthermore the stored tare value Whatever the case a new operation automatically cancels and substitutes the previous one NOTES The automatic tare is acquired only if the weight is of AT LEAST ONE DIVISION AND IS STABLE instability led indicator is off and VALID In other words the OVERLOAD condition must not be created 7 2 PRESET TARE To enter the tare value with the keyboard type the desired tare value one digit at a time and press TARE The C key quickly clears the digited value The indicator automatically subtracts the entered value from the displayed weight the NET and gt T or indicators turn on as long as it is not greater than the instrument s maximum capacity The display shows furthermore the stored tare value identified with PT Preset Tare In any case when a new Tare value is entered the preceding one is cancelled and substituted NOTE In the printout the manual tare is identified with PT Preset Tare 7 3 CALCULATED MANUAL TARE With the CALCULATOR function one can add or subtract from the current tare the result of an operation between two values entered with the keyboard For the functioning specifics see the 15 1 CALCULATOR section 29 3590EKR 3590EXP 3590 CPWE CPWET series in
82. t be executed before executing a totalisation useful for the formulations By setting A MAnd and putting a weight on an unloaded scale it will automatically be tared this will be done only if there is no tare and there is a stable gross weight of at least 5d 7 10 AUTOMATIC TARE AFTER THE TOTALISATION By setting Auto in the F ModE gt gt totAL gt gt t tot step TECH MAN REF one enables the automatic execution of the tare after the totalisation useful for executing formulations or dosages while by setting MAnuAL the execution of the tare must be executed only manually NOTES The tare both automatic and manual substitutes the stored tare value but not the one of the first executed tare useful for executing formulations or dosages 7 11 FIRST TARE OPERATION IN FORMULATION OR DOSAGE SYSTEMS In the formulation applications it s possible to store and print the first executed tare the stored value can also be shown on the LCD display See section 4 2 4 7 12 RESTORING TARE AND ZERO AT THE START UP By setting EnAbLE in ModE gt gt rEStAr step TECH MAN REF one enables the restoring of the active tares before the instrument is turned off and if the actual gross weight and the last gross weight stored before the instrument is turned off are higher than zero the last stored ZERO value is set otherwise the instrument carries out the auto zero function NOTE The tares are restored as predetermined tares 8 M
83. t least 20 divisions in UNLOADING The printout is reenabled depending on how the F ModE gt gt rEACt REACTIVATIONS parameter has been programmed in the TECHNICAL SET UP TECH MAN REF The simple print function excludes the totalisation and vice versa With the NON APPROVED instrument The printing works if there is a NET WEIGHT greater than zero or a NET WEIGHT lower than zero in UNLOADING he print key does not exclude the totalisation and it s always active the programming of the F ModE gt gt rEACt REENABLINGS parameter of the TECHNICAL SET UP TECH MAN REF is not taken into consideration TOTALIZATION Programmable printout After a totalisation made with the F6 key a printout is made of the linked format For the totalisation conditions see section 13 2 6 PRINTING OF THE HEADING upon the first executed totalisation Programmable printout See section 14 2 PARTIAL TOTAL Programmable printout By pressing the F8 key the resetting of the PARTIAL TOTAL and the printing of the linked format are made Alternatively it s possible to automatically execute the function as described in section 13 2 9 GENERAL TOTAL Programmable printout By pressing the F9 key the resetting of the GENERAL TOTAL and the printing of the linked format are made GRAND TOTAL Programmable printout By pressing the F10 key the resetting of the GRAND TOTAL and the printing of the linked format are made 44
84. t way through the TECHNICAL SET UP TECH MAN REF 3590EKR 3590EXP 3590 CPWE CPWET series indicator E AF02 02 12 05 EN U 4 1 4 HELP MENU By pressing at length the HELP key it is possible to access a menu containing the list of keys with the relative function and status locked or unlocked indication The display shows in the upper part the key followed by the code of the linked function in the lt lt F Keys gt gt step and a symbol Indicating whether the key is unlocked or locked in lt lt EN KEYS gt gt step in the lower the description of the linked function scroll the list with the arrow keys 4 press the C key to exit 4 1 5 INDICATOR CONNECTED TO PC KEYBOARD possible to connect a PC keyboard optional used to emulate the functions of the indicator keys The keys are managed in the following way KEYBOARD KEY OR FUNCTION EMULATE E C key SC If pressed at start up it allows entering in the technical set up In the alphanumeric input it deletes all entered characters C key ca If pressed at start up it allows entering in the technical set up vano In the alphanumeric input it cancels first the characters which follow the cursor then the ones which precede it one at a time Fn key Confirms the entered value Enters the displayed step Quick entry of a numeric and alphanumeric string through the CAPS LOCK or SHIFT key it is pos
85. tant one can enter the contents of the programmed INPUT TEXTS 2 The LCD display shows in in the first line in which XX is the index of the free text from 0 to 14 and THE HEADING on the second line or Empty if empty 3 Use the arrow keys to select the text to be filled in and press ENTER now one can enter the alphanumeric text in the second line of the display see chapter 4 1 2 ENTERING ALPHANUMERIC TEXT 4 Press ENTER to store and pass on to the following stored TEXT by confirming the last entered text one returns automatically to the weigh functioning it is possible to exit also with the C key while in the text selection modification phase NOTE e he entered texts remain in storage until these are substituted or cancelled e fnotext has been configured the pressing of the F4 key has no effect e Through specific print macros it s possible to automatically cancel the contents of all the texts right after their printing TECH MAN REF For information on the entry of the alphanumeric texts see section 4 1 2 ENTERING ALPHANUMERIC TEXT QUICK MODIFICATION OF AN INPUT TEXT By linking the number of a specific input text to the function 113 preamble function in the lt lt F KEYS gt gt step TECH MAN REF it is possible to access directly to the modification of it with a direct key for example F1 key to quickly access the text 0 and F2 key to quickly access the text 1 33 3590EKR 3590EXP
86. the SETUP level lt lt En KEYS gt gt step see section 4 1 4 4 2 3 BATTERY LEVEL INDICATION The indicator is able to recognise whether it is powered by mains or by battery and indicate its charge level to enable the battery level indication one should configure the lt lt bt LEVEL gt gt step The charge level is shown during weighing by the battery symbol charged battery partially charged battery discharged battery connect the indicator to the mains for recharging the battery if provided for by that model or replacing the battery The indicator shows also when the battery is being recharged if provided for the model RECHARGE PHASE gt lio 85 A3 COMPLETED RECHARGE NOTES During the recharge the instrument can be normally used The instrument automatically turns off when the voltage goes below the minimum level 4 2 4 TILT DEVICE The TILT is a device which inhibits the indicator s weighing system and starts working when the instrument s inclination is greater than 2 for the pallet truck application or 5 for application on lift trucks The tilt message is shown on the display alternately with the weight value The activation of the tilt alarm has a delay of about three seconds from the detection of the exceeding inclination oee the electrical connection scheme TECH MAN REF for the connection of the device 23 3590EKR 3590EXP 3590EXT CPWE CPWET ser
87. tion with the GENERAL TOTAL equal to zero It is useful to print the COMPANY HEADING or the other DESCRIPTIONS when it s not necessary to print these in each single accumulation operation 14 3 REPETITION OF THE LAST EXECUTED PRINTOUT By pressing in sequence the 2ndF and F5 keys the last executed printout is repeated this function can not be reenabled NOTE If one wants always to execute more than one printout it s advisable to use the ticket copies function see section 14 2 14 4 STANDARD PRINTING FORMATS The SEtuP gt gt SEriAL gt gt dEF Prn parameter of the set up environment TECH MAN REF allows to enable the standard printouts for the TPR printer NOTE By enabling these printouts all the formatted print formats will be CANCELLED and will be SUBSTITUTED by the standard formats which automatically will be linked to the available print functions 15 OTHER FUNCTIONS 15 1 CALCULATOR Through function 114 combinable with the desired key lt lt F KEYS gt gt step TECH MAN REF one enables the calculator function 15 possible to execute the following operation e ADDITION e MULTIPLICATION SUBTRACTION Procedure Enter the first value using the numerical keyboard Press F1 to add F2 to multiply F3 to subtract the value TERMINATE THE OPERATION TYPE the second value and PRESS ENTER the result will be shown for a few seconds on the display TYPE the second value and PRESS TARE the result will be shown for a
88. tions are the same for the functioning mode on the gross weight A OUT1 STATUS ENABLED DISABLED 51 0 51 NET WEIGHT Functioning without hysteresis rL iSt HYSTERESIS parameter set as iSt oFF The operating mode is the same as the previous one except that just one SETPOINT is entered for each output S 1 on for this purpose the access to the S 1 oFF parameter is inhibited The entry and specifications are the same for the functioning mode on the gross weight 15 4 1 11 SETPOINT ON QUANTITY By selecting this function one enables the output function on the quantity put on the scale The setpoint function remains enabled also when the weight is shown on the display by pressing the SWITCH key but it is disabled automatically when the instrument loses the stored reference for example when the C key is pressed 15 4 1 12 SETPOINT ON THE NEGATIVE QUANTITY By selecting this function one enables the output function on the basis of the negative quantity useful in the counting by extraction functions The setpoint function remains enabled also when the weight is shown on the display by pressing the SWITCH key but it is disabled automatically when the instrument loses the stored reference for example when the C key is pressed 15 4 1 13 SETPOINT ON THE PARTIAL TOTAL QUANTITY By selecting this operation mode one enables the function of the output on the sum between the NET weight on the scale and
89. to store up to 200 customers having five descriptions of 30 characters each customer is linked to a storage number from 0 to 199 The selected customer is shown on the display during the weighing operations and can be printed through the relative printing block and linked to an article see previous section ACCESS KEY MENU _ ef New Et gt Delete OGM Research _ E gt E cm aT Le 11 2 1 ENTRY 1 Press the F2 key to enter in the customer database 2 NOTE is advisable to leave empty the 0 memory storage since it is used for the temporary entry see section 11 2 6 TEMPORARY ENTRY By using the arrow keys 4 With the keyboard the storage number 3 Press F1 to enter the customer in the desired position or in the first empty position if an already occupied position has been selected 4 should fill in the following fields only the necessary ones are requested by pressing ENTER to confirm e TEXT 1 first description line up to 30 characters e TEXT 2 second description line up to 30 characters TEXT 3 third description line up to 30 characters e TEXT 4 fourth description line up to 30 characters e TEXT 5 fifth description line up to 30 characters 5 Press the C key to return to the weighing phase 11 2 2 MODIFICATION 1 Press the F2 key to enter in the customer database 2 Select the storage to be modified by using the arrow keys 4
90. vironment in the F ModE gt gt totAl gt gt tot tyP parameter TECH MAN REF 13 2 1 1 TOTALISER IN LOADING This type of totaliser allows totalising a positive net weight To do this one should 1 Put the article on the scale and wait for the weight to become stable 2 Press the F6 key manual totalisation the display shows for an instant the message totAL accompanied by an acoustic signal the weight on the scale is accumulated in all the totals and if a print format has been linked the printing will be made 3 Remove the article from the scale put another one and repeat the operation described in point 2 13 2 1 2 TOTALISER IN UNLOADING This type of totaliser allows totalising with a negative net weight To do this one should 1 the articles to be unloaded on the scale and wait for the weight to become stable 2 Tare the weight with the TARE key 3 Unload the weight and wait for stability the unloaded weight and the quantity will be viewed with a negative value 4 Press F6 manual totalisation the display shows for an instant the message totAL accompanied by an acoustic signal the weight on the scale is accumulated in all the totals if a print format has been linked a printout will be made 5 Repeat the operations from point 3 13 2 1 3 TOTALISER IN LOADING AS WELL AS IN UNLOADING This type of totaliser allows totalising both with a positive net weight as well as with a negative net weight See sections