1. 5 22 NPort Z3150 Series Web Console Configuration TCP Alive Check Time CAN Description This field specifies how long the NPort will wait for a response to keep alive packets before closing the TCP connection The NPort checks connection status by sending periodic keep alive packets 0 The TCP connection will remain open even if there is no response to the keep alive packets 1 to 99 If the remote host does not respond to the packet within the specified time the NPort will force the existing TCP connection to close Inactivity Time AA Options 0to65535 ms Description This field specifies the time limit for keeping the connection open if no data flows to or from the serial device 0 The TCP connection will be kept active until a connection close request is received even if data is never received For many applications the serial device may be idle for long periods of time so 0 is an appropriate setting 1 to 65535 If there is no activity for the specified time the connection will be closed When adjusting this field make sure that it is greater than the Force transmit time Otherwise the TCP connection may be closed before data in the buffer can be transmitted Connection Control must be set to Any character Inactivity time for this setting to have effect Ignore Jammed IP Default Disable ss Options Disable Enable Description This field specifies how an unresponsive IP address
2. Execute cd to go to the root directory 5 YE Copy the driver file npreal2xx tgz to the directory PAA NPort Z3150 Series Installing and Configuring the Software Execute tar xvfz npreal2xx tgz to extract all files into the system 6 Execute tmp moxa mxinst For RedHat AS ES WS and Fedora Corel execute tmp moxa mxinst SPi The shell script will install the driver files automatically 7 After installing the driver you will be able to see several files in the usr lib npreal2 driver folder mxaddsvr add server map TTY port mxdelsvr delete server undo TTY port mapping mxloadsvr reload server mxmknod create device node TTY port mxrmnod remove device node TTY port mxuninst remove TTYport and driver files At this point you may map the TTY port to the NPort serial port Mapping TTY Ports Make sure that you set the operation mode of the desired NPort serial port to Real COM mode After logging in as a super user enter the directory usr lib npreal2 driver and then execute mxaddsvr to map the target NPort serial port to the host TTY ports The syntax of mxaddsvr is as follows mxaddsvr VPort IP Address Total Ports Data port Cmd port The mxaddsvr command performs the following actions 1 Modify npreal2d cf 2 Create TTY ports in directory dev with major and minor number configured in npreal2d cf 3 Restart the driver Mapping TTY ports automatically To map TTY ports automatic
3. 4001 Oparating Saliings Destination IP address 4 4001 Port 1 Serial i l o Local listen port 4001 Pont 2 ZigBee Accessible IP Settings Auto Warning Settings Data Packing CESAR TUNAO Packing length 0 0 1024 Monitor Delimiter 1 o0 Hex C Enable Change Password Load Factory Default Delimiter 2 00 Hex C Enable Save Restart Delimiter process Do Nothing v Processed only when packing length is 0 Force transmit 0 i ko 65535 ms O Apply the above settings to all serial ports When Mode is set to UDP on a serial port s Operation Modes page you will be able to configure additional settings such as Destination address 1 through 4 Local listen port and Packet length Destination Address 1 to 4 Options IP address range and port e g 192 168 1 1 to 192 168 1 64 and 4001 Description In UDP mode you may specify up to 4 ranges of IP addresses for the serial port to connect to At least one destination range must be provided The maximum selectable IP address range is 64 addresses However you can enter multicast addresses in the Begin field in the form xxx xxx xxx 255 For example enter 192 127 168 255 to allow the NPort to broadcast UDP packets to all hosts with IP addresses between 192 127 168 1 and 192 127 168 254 Local Listen Port Description This field specifies the UDP port that the NPort listens to and that other devices must use to contact the attached serial dev
4. NPort Web Console Total Solution for Industrial Device Networking x 192 168 127 254 MAC Address 3 Firmware O x i Vs 93 Www moxa com 00 90 E8 00 00 03 1 0 Build 11112915 Main Menu Overview Quick Setup Export Import Basic Settings Network Settings ZigBee Settings Serial Settings Operating Settings Accessible IP Settings Auto Warning Settings Upgrade Firmware Monitor Line Async Async atingas CE ZigBee Settings Change Password Load Factory Default Save Restart Monitor PAN Refresh No Type Alias Name FAV Parent Short TxTotalCnt RxTotalCnt DSR DTR RTS CTS DCD Ver Address Address 6 3 NPort Z3150 Series Monitor ZigBee Settings NPort Web Console Windows Internet Explorer Go y je http 192 168 127 254 p gt x 2 NPort Web Console Model NPort Name Main Menu Overview Quick Setup Export Import Basic Settings Network Settings ZigBee Settings Serial Settings Operating Settings Accessible IP Settings Auto Warning Settings Upgrade Firmware Monitor Line Async Async Settings ZigBes Change Password Load Factory Default Save Restart Z3150 IP NPZ3150_123 A Total Solution for Industrial Device Networking 192 168 32 122 123 cv Serial NO Monitor ZigBee Settings PAN ID 0x0000 Topology Tx Mode Mesh Start Byte Transparent 0x23 Channel Output Power 11 Web Co
5. 2 pin El E al E Exit Search SearchIP Locate Console Assign IP Ur Lock Upgrade heal _ LANT MAC Address LANT IP Address LANZ MAC Address LANZ IP Address NPort 6450 00 90 E 8 14 10 6F 192 168 395 156 N Port Me 7 OO 30 68 00 1 1 00 1 Je 1 68 33 1 8 NPort 23151 00 90 8 00 00 03 192 169 127 254 7 14 NPort Z3150 Series Installing and Configuring the Software Modifying NPort IP Addresses 1 Once NPort Search Utility has found NPort device servers on the LAN you can modify any unit s IP address Select the desired NPort in the main window and click Assign IP on the main toolbar This will modify the IP address for the active network connection LAN or WLAN FE NPort Search Utility File Function Miew Help ae F i E of E Exit Search S5earchlP Locate Consol amp AssignIP Lrlock Upgrade E eas ED fee LANE MAL ies RIP tla MPort 6450 00 90 E8 1 4 10 6F 192 166 35 756 00 30 68 0011 a EERE 00 90 E8 00 00 03 danon i U au HM Port 23150 2 Enter the new IP address and netmask If multiple units were selected you may assign addresses sequentially by clicking Assign IP Sequentially Click OK to proceed FS Assign IP address O x f Static IP Address DHCP far All FP IF Assign IP Addres aC 30 8 00 00 03 192 165 35 112 255 255 255 0 Assign IP Sequentially X cone 3 The selected NPort will be restarted by NPort Search Utility with the n
6. 5 12 OULD UEF OWO apa ULEAD EAS 5 12 Advanced gt e Und Ss ate lentes cien le eee ee Gee teen eke een eee lea elec lesa lola ate teen ad 5 12 Sel Mele ra 5 12 SO CUI COLI AE A II pau eae tice mentee acd A EI 5 13 ENCLYOUON DECCrY DLIONW atzsannancnenexoenacesnanniomesennandusndnpnbnoudnonnnaninenpnanonandnonbnondnoniameascinanseenaeamanneeran 5 13 AE SA2 DIS F OY wetenuciautahatnantatacinineen tech erenines ene hic O 5 13 serial Settings gt PORN on 5 13 POLAINAS ANO PRO O TN 5 13 BatduRa teclista antracita dad dde nel 5 14 DataibliSaa ACEC EET EEEE ROETE REEEOPEN ERRECART AEAEE EEEOE EPRA EEEN ERNE PEENE EE ERREN tarados 5 14 it Se ee A T A 5 14 FOW A E enna men Sennen nan ee ee Annan anes en Th meR Seen ir 5 14 A O 5 14 A A A nneteecoun 5 15 oporana Setas gt POr Ol 7 teta dede lacada dades led lla taiaos 5 15 Settings Tor RealCOM MOS ai ii AAA AAA AAA A AAA AA 5 15 TEPAV CHEEK TIM AAA 5 16 MAREO SC OTE wee tere tee a a a a a a ee ee a a a a a a a a a are 5 16 ae lps lA EEE emi Rpts RRC airy eR ph eres ire Re RSS SS Re aL OR ION PORTER SN IR 5 16 AMO AE lo rr 5 17 Connection Goes DOW srnrrentas nino oie taas 5 17 Packe Lenin da 5 17 DIMELO E ue osetia 5 17 BYE qa Reo wae el Oyo hc ete add dida add dada lla do de 5 18 FOrce Trannon Eiee nei A E TEENE EE EE arta ritare eA 5 18 Settings 10 EGP Server MOda Ae E AEE AA 5 19 EP AVE CROCK TITIO rnEeE EE TE A EEEE 5 19 MACEVE TINE en E ee E Me ee EEE T nn nn E men mem re 5 19 MAR
7. MB II IS AIR A 2 INteraces Mi tattoo a a cn eee ee nome eer eae a ee eer ee er eer ratito aleta A 2 IP MI 0 A OR A 2 ICME 1 O a a suc cee ensues sean teen cues seen cece cee cece a A 2 VOP MIB ae ag a a aaa a sae ae a Me ae a Na ae ae a ana aaa aera Mee ag a as Mace ae aa eee ae te a tae A 2 Address Trans ao ara rnd ete ono tee Matias tlie serena ie A 3 TG Fee I norton acicate ante re dolo ltd dolo tooo dto dodo dto dolo dolo dto loo E A 3 A O O O A 3 RECI IRS 2252 MIB OD ICClSinaccscausaeetedutrduededaialndatad dadatedaiedetedateaniedekeauiedatndudecutedateaudedateaatednacenseaces s A 3 Generic RS 235 2 I1Ke Group vs os A 3 RS 232 MKE General PORE tablas drid A 3 RS 232 11K8 ASynChronous Port GOUD iran rant innne noron aTe ioe reo ovat svar seai asa tear N A 3 ANN TANTO Se Cae A acca a E ad el dl ld del ele tame nenauaneee dean A 3 The OULDUL SIGN al Val Greteceesee sete dd Mik Mitte kdb did ttrck hick deinen A 4 Di ZigBee Ii A snes seaseuiss weedeelnswelusueesewesuase ews weudeeusweussesseuseverewwe ess B 1 DEVICE NY DO ial vail AAA AAA AAA AAA AAA AAA AAA AAA AAA AAA AAA AAA AAA AAA AAA A B 2 NetWork ONO dae E neonate B 2 Ex Well Known POr NUDO Sun ana orale C 1 D Federal Communication Commission Interference Statement sssss2222 5 D 1 EY FGC Warning Stato Mentira E 1 The following topics are covered in this chapter O O O O Overview Package Checklist Product Fe
8. Model NPort 23150 IP 192 168 35 101 Name NPZ3150_20 Serial NO 20 Serial Settings Main Menu l i Port 1 Overview Quick Setup Port alias Exportlmport Basic Settings Serial Settings Network Settings Zigbee Settings Baud rate 115200 Data bits 8 iv Stop bits 1 a Accessible IP Settings Parity None Auto Warning Settings Flow control RTSICTS vw Upgrade Firmware FIFO Enable O Disable Monitor Interface RS 232 v Change Password Load Factory Default Save Restart The Serial Settings page for the serial port is where serial communication settings are specified such as Baud rate Data bits and Stop bits Port Alias Options free text e g Secondary console connection Description This is an optional free text field to help you differentiate one serial port from another It does not affect operation of the NPort device server 5 13 NPort Z3150 Series Web Console Configuration ATTENTION Serial communication settings should match the attached serial device Check the communication settings in the user s manual for your serial device Baud Rate 50 75 110 134 150 300 600 1200 1800 2400 4800 7200 9600 19200 38400 57600 115200 230400 460800 921600 Description This field specifies the baudrate for the serial port 50 to 921600 The serial port will operate at the specified baudrate Data Bits This field specifies the number of stop
9. Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89 3 70 03 99 99 www moxa com su ort Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Asia Pacific Tel 886 2 8919 1230 Fax 886 2 8919 1231 Table of Contents Le gers o AAA yy na ees 1 1 O ae T eee eee ee ee eee 1 2 o a 1 2 PEO A A RN 1 2 Product SPecitca ON SA caca 1 3 A a Stred ia esis ia ae aa wie eee niles vee eine ee ee en eile eu ve uiee eee suuuewd ues tau eitwe ud vsuueedesuuuued eb 2 1 OAs BY oh Ree ee aN eee eee Re RY RE RC EE MTT ST RAT ST RT RT ST RT OT TT RT RT RTT CT TT ST TT TTT TT CTT RTT RT Tee Tee TE 2 2 Panlemieay OUl ss ieune gatas gn ranar an runs gue ga a a we a aa a a ae ee 2 2 ESTACA O Stoll liada errr rm TT tet Tet 2 2 hop Panel LED Indicators renn rriren annn nn onn On inorder aay ooo dau co noir 2 2 Enda Panel LED MGIC US eae ae ieee aie eer yeu A A E aaa 2 3 PUIICHIGHALOW RESISTORS TOP Ra 422 48 ice ire ca cite ott crite ute e ile cee vine cat cdo 2 3 Seige lel E ee ee ee ee a ee ee em er eee ere 2 4 CONAECUNTO SA AS 2 4 COMNEEHAG A A IN 2 5 Connecting TINS POW AE A eat 2 5 Connecting toa Seral DEVICE aaa 2 5 Si AMIA LP CORTO UNE cE OI tai israel aaa llenen 3 1 ON a aa oo coa ace odo 3 2 Raco Oe rauile we So CLUIN Cs atte A E T E E redee 3 2 USING ARPTOASSIGn IP Add art OO encata 3 2 Using the Telnet Cons
10. The frame format should be represented as below 1 Byte 4 Bytes 1 Byte 1 99 Bytes 1Byte y E CR 0x0D Start byte The head of the addressable mode command format which can be modified by the option Start Byte Dest Node ID This field contains 4 bytes that indicate what the desired ZigBee node is Length The length field is a byte count of the following Data field Data The data will be sent to the serial device connected to the desired ZigBee node Stop byte The tail of the addressable mode command format This example shows how to send the data ABCD to the ZigBee node with ID 3 Start Byte Dest Node ID Length Data Stop Byte 0x23 0x30 0x30 0x30 0x33 0x04 0x41 0x42 0x43 0x44 Ox0D Start Byte Berau 4 023 The head of addressable mode command format on Coordinator 5 12 NPort Z3150 Series Web Console Configuration Security Settings Encryption Decryption Default Disable Options Enable or Disable AES encryption for Zigbee security AES 128 bits Key Options HEX codes from 0 9 and A F Description Supply 128 bit AES data encryption Use the following rule to input the AES key Example BIN 1101 1111 0010 1101 0001 0101 1011 1110 0011 1000 0100 HEX D F 2 OD a q B E 3 88 4 Input the following values into the key field DF2D1 5BE384 total of 16 bytes with 32 HEX code characters Serial Settings gt Port 1 MOXN Total Solution for Industrial Device Networking
11. The wizard will begin installing the files After the files have been installed click Finish to complete the installation ie setup NPort search Utility Completing the NPort Search Utility Setup Wizard Setup has finished installing Por Search Utility on your computer The application may be launched by selecting the Installed icons Click Finish to esit Setup Finding NPort Device Servers on Network You can use NPort Search Utility to look up or change the IP address of any NPort device servers on the network Since the utility searches by MAC address rather than IP address all NPort units that are connect to the LAN will be located regardless of whether or not they are part of the same subnet as the host 1 In NPort Search Utility click Search on the main toolbar E NPort Search Utility l Joj x p a ET E Locate Console Assign IP UrrLock Upgrade 2 The utility will being searching for NPort device servers Searching e x Searching for NPort Show Pv6 Address Found 3 NPort s 8 second s left No Model LANT MAC Address LAN IP Address LANZ MAC Address LANZ IP Address 1 NPort 6450 00 90 E8 14 1C 6F 192 168 35 156 a 2 NPott W2250PIus US 00 90 E8 00 11 00 192 168 33 18 3 NPort 23150 O0 90 E8 00 00 03 192 168 127 254 3 When the search is complete NPort units that were found will be listed in the main window FS NPort Search Utility File Function View Help fal
12. be opened simultaneously When multiple connections are established serial data will be duplicated and sent to all connected hosts Data from hosts will be sent to the attached serial device on a first in first out basis Ignore Jammed IP Default Disable Options Disable Enable Description This field specifies how an unresponsive IP address is handled when there are simultaneous connections to the serial port Disable All transmission will be suspended if one IP address becomes unresponsive Transmission will only resume when all hosts have responded Enable Data transmission to the other hosts will not be suspended if one IP address becomes unresponsive Allow Driver Control Default Disable Options Disable Enable Description This field specifies how the port will proceed if driver control commands are received from multiple hosts that are connected to the port Disable Driver control commands will be ignored Enable Control commands will be accepted with the most recent command received taking precedence TCP Port Description This field specifies the TCP port number that the serial port will use to listen to connections and that other devices must use to contact the serial port Command Port This field specifies the TCP port number for listening to SSDK commands from the host 5 20 NPort Z3150 Series Web Console Configuration Packet Length Options 0to1024 Description This field
13. coordinator is activated and starts establishing its network The first thing this PAN coordinator does is select a unique PAN identifier that is not used by any other network in its radio sphere of influence the region around the device in which its radio can successfully communicate with other radios In other words it ensures that the PAN identifier is not used by any other nearby network Star Network Mesh Network Tree Network Simplest Best Reliability Large Scale Networks 0 Coordinator O Router TE End Device B 2 NPort Z3150 Series ZigBee Introduction In a Mesh topology each device can communicate directly with any other device if the devices are placed close enough together to establish a successful communication link Any devices in a peer to peer network can play the role of the PAN coordinator One way to decide which device will be the PAN coordinator is to pick the first device that starts communicating as the PAN coordinator In a peer to peer network all the devices that participate in relaying the messages are devices because devices are not capable of relaying the messages However an device can be part of the network and communicate only with one particular device a coordinator or a router in the network ZigBee supports a tree topology In this case a ZigBee coordinator PAN coordinator establishes the initial network ZigBee routers form the branches and relay the messages ZigBee end devices act as leaves of
14. days 6h 26m 15s lt lt Main menu gt gt 1 gt Basic settings 2 gt Network settings 3 gt ZigBee Settings 4 gt Serial settings lt 5 gt Operating settings 6 gt Accessible IP settings lt C gt Auto warning settings lt 8 gt Monitor lt 9 gt Ping lt a gt Change password lt b gt Load factory default lt u gt View settings lt s Save Restart lt g gt Quit Key in your selection 8 Press y to confirm action for save and restart configuration and press Enter The NPort will reboot with the new IP settings Ready to restart Cy Yes Cn Ho Key in your selection Y 3 4 Introduction to The following topics are covered in this chapter O Overview Real COM Mode TCP Server Mode TCP Client Mode UDP Mode 000 0 4 Operation Modes NPort Z3150 Series Introduction to Operation Modes Overview This chapter introduces the different serial port operation modes that are available on the NPort Z3150 Each serial port on the NPort is configured independently of the other ports with its own serial communication parameters and operation mode The serial port s operation mode determines how it interacts with the network and different modes are available to encompass a wide variety of applications and devices Real COM mode allows serial based software to access the NPort serial port as if it were a local serial port on a PC This mode is appropriate when your application reli
15. is handled when there are simultaneous connections to the serial port Disable All transmission will be suspended if one IP address becomes unresponsive Transmission will only resume when all hosts have responded Enable Data transmission to the other hosts will not be suspended if one IP address becomes unresponsive Destination Address 1 to 4 IP address and port e g 192 168 1 1 and 4001 Description This field specifies the remote host s that will access the attached device At least one destination must be provided This field supports the use of domain names and names defined in the host table 5 23 NPort Z3150 Series Web Console Configuration ATTENTION In TCP Client mode up to 4 connections can be established between the serial port and TCP hosts The connection speed or throughput may be low if any one of the four connections is slow since the one slow connection will slow down the other 3 connections Designated Local Port 1 to 4 Options 1to65535 This field specifies the TCP port number that will be used for data transmission with the serial port Connection Control Default Startup None MN Startup None Any Character None Any Character Inactivity Time DSR On DSR Off DSR On None DCD On DCD Off DCD On None Description This field specifies how connections to the device are established and closed Startup None The connection will be opened as the NPort starts up The connecti
16. may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation NOTE FCC Warning Statement This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e
17. powered on or was restarted after a firmware upgrade Warm start The NPort restarted without powering off Authentication failure An attempt has been made to open the web Telnet or serial console but the password was incorrect IP changed The IP address has been changed Password changed The password to the console has been changed DCD changed The DCD Data Carrier Detect signal has changed also indicating that the modem connection status has changed For example a DCD change to high also means Connected between local modem and remote modem If the DCD signal changes to low it also means that the connection line is down When the DCD changes the NPort Z3150 will immediately send an e mail or send an SNMP trap DSR changed The DSR Data Set Ready signal has changed also indicating that the data communication equipment s power is off For example a DSR change to high also means that the DCE is powered ON If the DSR signal changes to low it also means that the DCE is powered off 5 31 NPort Z3150 Series Web Console Configuration When the DSR changes the NPort Z3150 will immediately send an e mail or send an SNMP trap Event Description OO This feature helps the administrator manage how the NPort Z3150 sends e mail to pre defined e mail boxes when the enabled events such as Cold start Warm start Authentication failure etc occur To configure this feature click the Event Type Mail checkbox This
18. specifies the maximum amount of data that is allowed to accumulate in the serial port buffer before sending O Packet length is disregarded and data in the buffer will be sent as specified by the delimiter settings or when the buffer is full 1 to 1024 Data in the buffer will be sent as soon it reaches the specified length Delimiter 1 and 2 Options Disabled Enabled 0x00 to OxFF Description These fields are used to define special delimiter character s for data packing Enable Delimiter 1 to control data packing with a single character enable both Delimiter 1 and 2 to control data packing with two characters received in sequence When these fields are enabled serial data will accumulate in the serial port s buffer until the buffer is full or until the specified delimiter character s are received For example the carriage return character could be used as a delimiter in order to transmit each sentence or paragraph in a separate packet Data will be packed according to Delimiter process Delimiters must be incorporated into the data stream at the software or device level ATTENTION When Delimiter 1 is enabled Packet length must be set to 0 Delimiter Process Options Do Nothing Delimiter 1 Delimiter 2 Strip Delimiter Description This field specifies how data is packed when delimiter characters are received This field has no effect if Delimiter 1 is not enabled Do nothing Data accumulated in the ser
19. the Software NPort Search Utility Installing NPort Search Utility 1 The main installation window will open when you insert the Document amp Software CD Click INSTALL UTILITY to proceed Once the program starts running click Yes to proceed 2 The installation wizard will open Click Next to proceed i Setup NPort Search Utility Welcome to the NPort Search Utility Setup Wizard This will install NPor Search Utility Yer on pour computer Ik is recommended that you close all other applications before Continuing Click Nest to continue or Cancel to exit Setup ie setup NW Port Search Utility Select Destination Directory Where should Port Search Utility be installed Select the folder where you would like NFort Search Utility to be installed then click Nent C Program Files HPortS earch Accessories _ Adobe J Analog Devices ArcSoft Borland The program requires at least 0 5 MB of disk space Back Cancel 7 12 NPort Z3150 Series Installing and Configuring the Software 4 Indicate if you wish to create a desktop icon and click Next to proceed 2 Setup NPort Search Utility Select Additional Tasks Which additional tasks should be performed A Setup NPort Search Utility Ready to Install Setup le now ready to begin installing NPort Search Utility on your computer 7 13 NPort Z3150 Series Installing and Configuring the Software 6
20. 0g Dimension Without ears 67 x 100 4 x 22 mm 2 64 x 3 95 x 0 87 in With ears 90 x 100 x 22 mm 3 54 x 3 94 x 0 87 in 1 3 NPort Z3150 Series Introduction Environmental Limits Operating Temperature Standard Models O to 55 C 32 to 131 F Wide Temp Models 40 to 75 C 40 to 167 F Operating Humidity 5 to 95 RH Storage Temperature 40 to 85 C 40 to 185 F Power Requirements Input Voltage 12 to 48 VDC Power Consumption 120 mA 12 V Connector Power jack and terminal block Regulatory Approvals EMC CE EN55022 Class A EN55024 FCC Part 15 Subpart B Class A Safety UL UL60950 1 LVD EN60950 1 Reliability Automatic Reboot Trigger Built in WDT watchdog timer MTBF meantime between failures 1109589 hrs Warranty Warranty Period 5 years Details See www moxa com warranty Pin Assignments and Cable Wiring RS 422 2w RS 485 4w RS 485 Pa oo ww EEM DE EEE Co kore oar om ow Data ea oo 1 4 The following topics are covered in this chapter 0 0 0 a Overview Panel Layout LED Indicators gt Top Panel LED Indicators gt End Panel LED Indicators Pull High Low Resistors for RS 422 485 Function Block Connecting the Hardware gt Connecting to the Network gt Connecting the Power gt Connecting to a Serial Device 2 Getting Started NPort Z3150 Series Getting Started Overview This chapter presents the hardware features of the NPort Z3150 and explain
21. 3150 Series Installing and Configuring the Software 5 Verify the installation parameters and click Install to proceed f Setup NPort Windows Driver Manager Ready to Install Setup le now ready to begin installing WNPor Windows Driver Manager on your computer Click Install to continue with the installation or click Back if pou want to review or change any settings Destination location C Program Files PotD vl anager Start Menu folder NFort Windows Driver Manager 6 If you see a warning that the software has not passed Windows Logo testing click Continue Anyway to proceed Software Installation The software vou are installing has not passed Windows Logo testing to verify its compatibility with Windowe lt P Tell me why this testing i important Continuing your installation of this software may impair or destabilize the correct operation of pour system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the software vendor for software that has passed Windows Logo testing Continue Anyway 7 4 NPort Z3150 Series Installing and Configuring the Software 7 The wizard will begin installing the files When the files have been installed click Finish to complete the installation fo Setup NPort Windows Driver Manager loj x Completing the NPort Windows Driver Manager Setup Wizard Setup has fi
22. 5 32 NPort Z3150 Series Web Console Configuration Change Password MO gt XN Total Solution for Industrial Device Networking Model WPorn 23150 IP 192 168 35 101 Name NPZ3150_20 Serial NO 20 Change Password Ce rien Quick Setup Old password sid Exportilmpor ponimp New password sid Basic Settings Metwork Settings Retype password Zigbee Settings Serial Settings Operating Settings Password Accessible IP Settings Auto Warning Settings Upgrade Firmware SavelRestart The Change Password page is used to change the password first enter the old password in the Old password field Leave this blank if the NPort is not currently password protected Enter the new password twice once in the New password field and once in the Retype password Leave these fields blank to remove password protection ATTENTION If you forget the password the ONLY way to configure the NPort is by loading the factory defaults with the reset button All settings will be lost Before setting the password you may want to first export the configuration to a file Your configuration can then be easily imported back into the NPort if necessary Load Factory Default MO gt XN Total Solution for Industrial Device Networking Model NPort 23150 IP 192 168 35 101 Name NPZ3150_20 Serial NO 20 Load Factory Default ae sa This function will reset all MOXA NPort Server settings to their factory default values O
23. 6 Web COnsole MODNIM OF cercana aaa 6 1 OCC E e 6 2 MONO LIME OS 6 2 MONO AS Nono iaua 6 2 MONITO IAS Y NO SEEING inicia SA SOS LO r Tere TT ener errr 6 3 MORMON ZIG BCC unicidad 6 3 MONITO ZIG Bees Se UMNO Sad IA ce a E A E O 6 4 7 Installing and Configuring the Software siii ioe dia dd doce li dd lla 7 1 OVENI ia 7 2 NEOrE Windows DAVE Mande dl rd end is 7 2 Installing NPort Windows Driver Manager s sssssssssassnsnsenanrnnanansnnnnennnnenanrnnnanansnnnsennnrenanrsnnnansnnnnan 7 2 Adding Mapped Serial Portu 7 5 Confquria Mapped ena lors al ab 7 8 AROS S arc UCI ee ane rE 7 12 Instala Por Search Ulead citar lala 7 12 Finding NPort Device Servers on NetWork dada 7 14 MOGINVING NPO TP Addresses adi 7 15 Upgrading NPOTE FINNA e cusisprptraaa ias 7 16 PATE Ra Wel o 7 17 BSG eo IS lagen mintenentratere 7 17 Installing Linux Real TTY Driver Files assssssnnnnansnnnnunsnnnnensnnnnannnnnnansnnnnennnnnnannnnnnunsnnnnennnnenannnnnnan 7 17 Mappa TIY PONS xc OO CR Ene 7 18 REMO Mapped A idos 7 18 REMOVING EMX ORAVE RIGS 0 IR 7 19 UNDEF a TES DIMES sitial llo dd dde dd lo de llo A dd o leed dos 7 19 TAStaling Ie UNID DD Vereda be acacia tes 7 19 Configuring the UNIX DVEF a ccsceatacatucasccatucedeta a a in a 7 20 A SNMP Agents with MIB II amp RS 232 Like GroupS s sssss2 s222225u2225uu220uuu20unnnn A 1 RECLZLS MIB Supported SNMP VarlaDl eS suicidar tala dape A 2 Sy Seem
24. 8 127 254 Netmask and Gateway for IP settings IP Address Default 192 168 127 254 2 2 2 22222 OO Options IP address e g 192 168 1 1 Description This field is for the IP address that will be assigned to your NPort device server An IP address is a number assigned to a network device such as a computer as a permanent address on the network Computers use the IP address to identify and talk to each other over the network Choose a proper IP address that is unique and valid in your network environment If your device server will be assigned a dynamic IP address set the IP configuration parameter appropriately Netmask Default 255 255 255 000 2 2 2222 O Options Netmask setting e g 255 255 0 0 Description This field is for the subnet mask A subnet mask represents all of the network hosts at one geographic location in one building or on the same local area network When a packet is sent out over the network the NPort device server will use the subnet mask to check whether the desired TCP IP host specified in the packet is on the local network segment If the address is on the same network segment as the device server a connection is established directly from the device server Otherwise the connection is established through the gateway as specified in the Gateway parameter 5 9 NPort Z3150 Series Web Console Configuration IP address e g 192 168 1 1 Description This field i
25. Consult the dealer or an experienced radio TV technician for help CAUTION Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Prohibition of Co location This device and its antenna s must not be co located or operating in conjunction with any other antenna or transmitter Safety Information To maintain compliance with FCC s RF exposure guidelines when installing and or operating this equipment you should maintain a minimum distance of 20 cm between the transmitter and your body Use only the supplied antenna Unauthorized antennae modifications or attachments could damage the transmitter and may violate FCC regulations Please refer to the book ZigBee Wireless Networks and Transceivers
26. DNS client actively querying the DNS server for the IP address associated with a particular domain name SNMP Settings SNMPvi Default Enable Options Enable or Disable Description Simple Network Management Protocol SNMP is an Internet standard protocol for managing devices on IP networks NPort Z3150 supports SNMP version 1 In some cases you can disable this function Community name Default pubic OOS Options free text 1 to 39 characters e g private Description A community name is a plain text password mechanism that is used to weakly authenticate queries to agents of managed network devices 5 10 NPort Z3150 Series Web Console Configuration Contact Options free text 1 to 39 characters E g Support 886 89191230 300 Description The SNMP contact information usually includes an emergency contact name and telephone or pager number Location free text 1 to 39 characters E g Floor 1 office 2 Description Specify the location string for SNMP agents such as NPort Z3150 This string is usually set to the street address where the NPort Z3150 is physically located ZigBee Settings NPort Web Console Windows Internet Explorer 4 lol x GA Y http 192 168 127 254 Dr its x NPort Web Console x A ke Y MO gt XN Total Solution for Industrial Device Networking Wwww moxa com Model NPort Z3150 IP 192 168 127 254 MAC Address 00 90 E8 00 00 03 Name NPZ3150_3 Se
27. DP MIB UdpInDatagrams UdpNoPorts UdpInErrors SysContact SysName SysLocation ifOperStatus ifLastChange ifinOctets ifinUcastPkts ifinNUcastPkts ifinDiscards if nErrors ifinUnknownProtos ipOutDiscards ipOutNoRoutes ipReasmTimeout ipReasmReqds ipReasmOKs ipReasmFails ipFragOKs ipFragFails ipFragCreates ipAdEntAddr IcmpInTimestamps IcmpTimestampReps IcmpInAddrMasks IcmpOutMsgs IcmpOutErrors IcmpOutDestUnreachs IcmpOutTimeExcds IcmpOutParmProbs IcmpOutSrcQuenchs UdpOutDatagrams UdpLocalAddress UdpLocalPort SysServices ifOutOctets ifOutUcastPkts ifOutNUcastPkts ifOutDiscards ifOutErrors ifOutQLen ifSpecific ipAdEntIfIndex ipAdEntNetMask ipAdEntBcastAddr ipAdEntReasmMaxSize IpNetToMedialfIndex IpNetToMediaPhysAddress IpNetToMediaNetAddress IpNetToMediaType IpRoutingDiscards IcmpOutRedirects IcmpOutEchos IcmpOutEchoReps IcmpOutTimestamps IcmpOutTimestampReps IcmpOutAddrMasks IcmpOutAddrMaskReps NPort Z3150 Series Address Translation AtIfIndex AtPhysAddress TCP MIB tcpRtoAlgorithm tcpRtoMin tcpRtoMax tcpMaxConn tcpActiveOpens tcpPassiveOpens tcpAttempFails SNMP MIB snmpInPkts snmpOutPkts snmpInBadVersions snmpInBadCommunityNames snmpInASNParseErrs snmpInTooBigs snmpInNoSuchNames snmpInBadValues snmpInReadOnlys snmpInGenErrs RFC1317 RS 232 MIB Objects SNMP Agents with MIB II amp RS 232 Like Groups AtNetAddress tcpEstabResets tcpCurrEstab tcpInSe
28. Delimiter Process Options Do Nothing Delimiter 1 Delimiter 2 Strip Delimiter Description This field specifies how data is packed when delimiter characters are received This field has no effect if Delimiter 1 is not enabled Do nothing Data accumulated in the serial port s buffer will be packed including delimiters Delimiter 1 One additional character must be received before the data in the serial port s buffer is packed Delimiter 2 Two additional characters must be received before the data in the serial port s buffer is packed Strip Delimiter Data accumulated in the serial port s buffer will be packed but the delimiter character s will be stripped from the data Force Transmit Default Joms o O Options 0to65535 Description This field controls data packing by the amount of time that elapses between bits of data When using this field make sure that Inactivity time is disabled or set to a larger value Otherwise the connection may be closed before the data in the buffer can be transmitted O If serial data is not received the NPort will wait indefinitely for additional data 1 to 65535 If serial data is not received for the specified amount of time the data that is currently in the buffer will be packed for network transmission The optimal force transmit time depends on your application but it must be at least larger than one character interval within the specified baudrate For example as
29. NPort Please refer to Chapter 5 and 6 for details on using the web console for configuration Factory Default IP Settings Network Interface IP Configuration IP Address Netmask _ LAN 192 168 127 254 255 255 255 0 If your NPort is configured to obtain its IP settings from a DHCP or BOOTP server but is unable to get a response it will use the factory default IP address and netmask ATTENTION If you forget the IP address of your NPort you can look it up using the NPort Search Utility After NPort Search Utility has found all NPorts on the network each unit will be listed with its IP address Please refer to Chapter 7 for additional information on using NPort Search Utility Using ARP to Assign IP Address The ARP Address Resolution Protocol command can be used to assign an IP address to the NPort The ARP command tells your computer to associate the NPort s MAC address with the specified IP address You must then use Telnet to access the NPort at which point the device server s IP address will be reconfigured This method only works when the NPort is configured with default IP settings Select a valid IP address for your NPort Consult with your network administrator if necessary Obtain the NPort s MAC address from the label on its bottom panel From the DOS prompt execute the arp s command with the desired IP address and the NPort s MAC address as in the following example arp s 192 168 200 100 00 90 E8 xx xx
30. NPort Z3150 Series User s Manual Second Edition February 2015 www moxa com product 2015 Moxa Inc All rights reserved NPort Z3150 Series User s Manual The software described in this manual is furnished under a license agreement and may be used only in accordance with the terms of that agreement Copyright Notice Trademarks 2015 Moxa Inc All rights reserved The MOXA logo is a registered trademark of Moxa Inc All other trademarks or registered marks in this manual belong to their respective manufacturers Disclaimer Information in this document is subject to change without notice and does not represent a commitment on the part of Moxa Moxa provides this document as is without warranty of any kind either expressed or implied including but not limited to its particular purpose Moxa reserves the right to make improvements and or changes to this manual or to the products and or the programs described in this manual at any time Information provided in this manual is intended to be accurate and reliable However Moxa assumes no responsibility for its use or for any infringements on the rights of third parties that may result from its use This product might include unintentional technical or typographical errors Changes are periodically made to the information herein to correct such errors and these changes are incorporated into new editions of the publication Technical Support Contact Information
31. No Activate the rule IP Address Netmask Exportlmport Basic Settings Network Settings Zigbee Settings Serial Settings Operating Settings 0 O 4 QOG Ml A U N Upgrade Firmware Monitor 10 Change Password 11 Load Factory Default 12 Save Restart OOHOOOOAOOORORORORARARAROORRO The NPort Z3150 uses an IP address based filtering method to control access to itself Accessible IP Settings allows you to add or block remote host IP addresses to prevent unauthorized access Access to NPort Z3150 is controlled by IP address That is if a host s IP address is in the accessible IP table then the host will be allowed to access the NPort Z3150 You can allow one of the following cases by setting the parameter e Only one host with a specific IP address can access the NPort Z3150 Enter IP address 255 255 255 255 e g 192 168 1 1 255 255 255 255 e Hosts on a specific subnet can access the NPort Z3150 Enter IP address 255 255 255 0 e g 192 168 1 0 255 255 255 0 e Any host can access the NPort Z3150 Disable this function by un checking the Enable the accessible IP list checkbox Refer to the following table for more configuration examples 192 168 1 120 255 255 255 255 5 29 NPort Z3150 Series Web Console Configuration Auto Warning Settings gt E mail and SNMP Trap gt E mail server NM OXN Total Solution for Industrial Device Networ
32. S SLO RN gi etka g ie a A gg 5 20 LINO JAM Oriana 5 20 A A A NEEC OEEC nnn an ce 5 20 TCP POR us dlcdan 5 20 COI ANG Porra is 5 20 A es 5 21 DICTA Ts GING Ze cass acccns nnd vnueeus dl T E ea iemian MENT E DEEL NE INET HARE ReDE UMAR RuReR EE 5 21 DEMET hole Cee ep ea eT AA SS AS TT TS TETRIS SANAR EOS 5 21 Force TRANS ticos 5 22 Sectings for CP CiHeme MOC a coo 5 22 TEF AMEC NCCE Ml gat tear eee ee oe 5 23 A A 5 23 Ignore Jammed TR catalina 5 23 Destinado na daress toa 5 23 Desidiated OC PORE tOdO iO 5 24 Connection CONTO muss ooo eaae 5 24 Packet Eeng a A A E EEE EEEE 5 24 DEMRE Land 5 25 DEMI POCOS S ask anteater ates ain ue aan eauceeug KE EEOAE EEA EEKAN ESANA EAEE AA S A 5 25 FOrce Trana Eeee dada 5 25 Settings tor UDP MOGE area eea aaa pita 5 26 Destination Address O Aerea EEEE 5 26 Eole MM Sa a we o A T E E EEEE E E T 5 26 Packe PONG U ireren a E 5 27 Bisioa ae A E EA E E E E N 5 27 DEMOR ee PEPE ERAN 5 27 Force Sl AAA A A E 5 28 UBrRMUtcas cia e iii dend 5 28 ACCES IDEA PS Std Soo alada ada 5 29 Auto Warning Settings gt E mail and SNMP Trap gt E mail Server occcccccccccnnnnnnnnncnnnnnnnn anar 5 30 Mal oee NE 5 30 ROME AMAS sa 5 30 SNMP Trap Server IP art reia 5 30 Auto Warning Settings Event Settings oie i e OE I STS TE EE IE le ia ei eee cota 5 31 RERI AN aia g A A E ee ee 5 32 change Pa sS WO d eaer a oda 5 33 Load Factory Derat na it T ean tows tee Ll dd ameter eee 5 33 SN ded Stel E os 5 34
33. Z3150 Series Web Console Configuration TCP Alive Check Time CAN Description This field specifies how long the NPort will wait for a response to keep alive packets before closing the TCP connection The NPort checks connection status by sending periodic keep alive packets 0 The TCP connection will remain open even if there is no response to the keep alive packets 1 to 99 If the remote host does not respond to the packet within the specified time the NPort will force the existing TCP connection to close Max Connection Description This field specifies the maximum number of connections that will be accepted by the serial port 1 Only one specific host can access this serial port and the Real COM driver on that host will have full control over the port 2 to 8 This serial port will allow the specified number of connections to be opened simultaneously With simultaneous connections the Real COM driver will only provide a pure data tunnel with no control ability The serial communication will be determined by the NPort rather than by your application program Application software that is based on the Real COM driver will receive a driver response of success when using any of the Win32 API functions The NPort will send data only to the Real COM driver on the host Data received from hosts will be sent to the attached serial device on a first in first out basis ATTENTION When Max connection is 2 or gr
34. abled the driver will not return any error even when a connection cannot be established to the NPort With this option enabled calling the Win32 Comm function will result in the error return code STATUS_NETWORK_UNREACHABLE when a connection cannot be established to the NPort This usually means that your host s network connection is down perhaps dueto a cable being disconnected However if you can reach other network devices it may be that the NPort is not powered on or is disconnected Not that Auto Network Re Connection must be enabled in order to use this function Fast Flush When enabled the driver flushes only the local buffer on the host for a Win32 PurgeComm function call When disabled both local and remote buffers are flushed If your application uses PurgeComm and performance seems sluggish try enabling Fast Flush Ignore TX Purge Applications can use the Win32 API PurgeComm to clear the output buffer Outstanding overlapping write operations will be terminated Select the Ignore TX Purge checkbox to ignore the effect on output data 4 Onthe Serial Parameters tab specify the communication settings that the host will use when opening the COM port 4 COM Port Setting O x Port Number 1 Port Selected 1st port is Port 1 Basic Settings Advanced Settings Seral Parameters Security FP Appl All Selected Parts These options will be saved on registry and used on few applications such as senal printer dri
35. ally you may execute mxaddsvr with just the IP address and number of ports as in the following example cd usr lib npreal2 driver mxaddsvr 192 168 3 4 16 In this example 16 TTY ports will be added all with IP 192 168 3 4 with data ports from 950 to 965 and command ports from 966 to 981 Mapping TTY ports manually To map TTY ports manually you may execute mxaddsvr and manually specify the data and command ports as in the following example cd usr lib npreal2 driver mxaddsvr 192 168 3 4 16 4001 966 In this example 16 TTY ports will be added all with IP 192 168 3 4 with data ports from 4001 to 4016 and command ports from 966 to 981 Removing Mapped TTY Ports After logging in as root enter the directory usr lib npreal2 driver and then execute mxdelsvr to delete a server The syntax of mxdelsvr is mxdelsvr JP Address Example cd usr lib npreal2 driver mxdelsvr 192 168 3 4 7 18 NPort Z3150 Series Installing and Configuring the Software The following actions are performed when executing mxdelsvr 1 Modify npreal2d cf 2 Remove the relevant TTY ports in directory dev 3 Restart the driver If the IP address is not provided in the command line the program will list the installed servers and total ports on the screen You will need to choose a server from the list for deletion Removing Linux Driver Files A utility is included that will remove all driver files mapped TTY ports and
36. aracter is 10 bits and the time required to transfer one character is 8 3 ms so the force transmit time to be larger than 8 3 ms UDP Multicast A multicast is a packet sent by one host to multiple hosts In multicast each host that belongs to a specific multicast group will receive multicast packets for that group To configure a host as a multicast receiver over the Internet it must inform the routers on its LAN The Internet Group Management Protocol IGMP is used to communicate group membership information between hosts and routers on a LAN The NPort Z3150 supports IGMP version 2 Port 1 Operation mode IDP W Begin Endl Port Destination IP address 1 4001 Destination IP address 2 14001 Destination IP address 3 4001 Destination IP address 4 14001 Local listen port 4001 You could key in the IP ex 239 1 1 1 that multicast group assigned into the column of Destination IP address and next NPort would automatically add the Group receiving all packets from this group in order to fulfill the function of multicast 5 28 NPort Z3150 Series Web Console Configuration Accessible IP Settings NM OXN Total Solution for Industrial Device Networking Model NPort 23150 IP 192 168 35 101 MAC Address Name NPZ3150_20 Serial NO 20 Firmware Accessible IP List Main Menu l ia C Enable the accessible IP list Not checking Enable will allow all IPs to connect Quick Setup
37. atures Product Specifications 1 Introduction NPort Z3150 Series Introduction Overview The NPort Z3150 is a gateway that provides computers with an Ethernet interface to a ZigBee PAN Unlike a bridge which logically extends a PAN across an Internet connection a gateway provides network services on behalf of a ZigBee PAN Software on any computer can control or monitor any ZigBee device in the PAN via the NPort Z3150 The following architecture is the application overview of the NPort Z3150 The NPort Z3150 can only act as the ZigBee Coordinator ZC Thus a converter such as the NPort Z2150 will be the ZigBee Router ZR and ZigBee End Device ZED Computer ZigBee ZigBee Coordinator Router ZigBee End Device gt y Coordinator ww Router dd End Device Package Checklist Before installing the NPort 23150 verify that the package contains the following items Standard Accessories e NPort Z3150 e Document amp Software CD e RJ45 to RJ45 Ethernet cross over cable e Warranty statement e Quick Installation Guide e 2 4 GHz omni directional antenna Optional Accessories e DK 35A DIN rail mounting kit 35 mm NOTE Please notify your sales representative if any of the above items are missing or damaged Product Features e Instant connection of any Ethernet device to a ZigBee network e RS 232 422 485 port supporting baudrates up to 921 6 Kbps e Web based configuration over Ethernet e Sec
38. ayed in the main window on the right Certain folders can be expanded by clicking the adjacent symbol For example if you click Serial Settings in the navigation panel the main window will show a page of basic settings that you can configure After you have made changes on a page you must click Submit in the main window before jumping to another page Your changes will be lost if you do not click Submit After you have finished modifying the desired pages you must save and restart the device server for the new settings to take effect You may complete this in one step by clicking Save Restart after you submit a change Changes will not take effect until they are saved and the NPort is restarted If you restart the NPort without saving your configuration all configuration changes will be lost Quick Setup Quick Setup streamlines configuration of your NPort into three basic and quick steps that covers the most commonly used settings At any time while in Quick Setup you may click the Back button to return to the previous step or the Cancel button to reverse all settings For more detailed settings please refer to the Basic Settings Network Settings ZigBee Settings and Operating Settings sections later in this chapter 5 3 NPort Z3150 Series Web Console Configuration MO gt XN Total Solution for Industrial Device Networking Model NPort 23150 IP 192 168 35 101 MAC Address Name NPZ3150_20 S
39. back up and recover your settings aa Go gt 2 http 192 168 127 254 hy x a NPort Web Console xl E A S TE KA OX N Total Solution for Industrial Device Networking www moxa com Model NPort Z3150 IP 192 168 127 254 MAC Address 00 90 E8 00 00 03 Name NPZ3150_3 Serial NO 3 Firmware 1 0 Build 11112915 Export Import Configuration a _ Configuration file Upload configuration A 0 TS Basic Settings Network Settings ZigBee Settings Serial Settings Operating Settings Accessible IP Settings Auto Warning Settings Upgrade Firmware Monitor Change Password Load Factory Default Save Restart Click Export to store all configuration data into a default file lt Servername gt txt Click the Import button to upload a configuration file to the NPort Z3150 5 5 NPort Z3150 Series Web Console Configuration Basic Settings 2 NPort Web Console Windows Internet Explorer Sje x EY Y http 192 168 127 254 PEx 2 NPort Web Console n Le 93 M OXN Total Solution for Industrial Device Networking www moxa com Model NPort Z3150 IP 192 168 127 254 MAC Address 00 90 E8 00 00 03 Name NPZ3150_3 Serial NO 3 Firmware 1 0 Build 11112915 Basic Settings A i Server Settings Overview Quick Setup Server name NPZ3150_3 Export Import Time Settings Network Settings ZigBee Settings Time zone GMT Greenwich Mean Time Dublin Edinburgh Lisbon London Serial Setti
40. bits used for each character frame Defaut none OO yO Options None Odd Even Space Mark This field specifies the type of parity bit used for each character frame Flow Control Default RTS CTS Options None RTS CTS XON XOFF DTR DSR This field specifies the type of flow control used by the serial port beta Enable Options Enable Disable Description This field specifies whether the serial port will use the built in FIFO A 128 byte FIFO is provided to each serial port for both Tx and Rx directions To prevent data loss during serial communication this should be set to Disabled if the attached serial device does not have a FIFO 5 14 NPort Z3150 Series Web Console Configuration Interface Options RS 232 RS 422 RS 485 2 wire RS 485 4 wire Description This field specifies the type of interface the serial port will use Operating Settings gt Port 1 or 2 NA OXN Total Solution for Industrial Device Networking www mo Model NPort Z3150 IP MAC Address Name NPZ3150_20 Serial NO Firmware 1 0 Build 11090913 Operation Modes Main Menu iena Port Operating Mode Packing Length Delimiter 1 Delimiter 2 Delimiter Process Force Tr Quick Setup 0 00 Disable 00 Disable Do Nothing 0 Exportimport 1 RealCOM TCP alive check time 7 Max connection 1 Basit Settings Network Settings 0 00 Disable 00 Disable Do Nothing 0 2 RealCOM TCP alive check time 7 Zigbee Settings i ae Max co
41. e force transmit time to be larger than 8 3 ms Settings for TCP Client Mode MOXA Model Name Total Solution for Industrial Device Networking Main Menu Overview Quick Setup Exportlmport Basic Settings Network Settings Zigbee Settings Serial Settings Operating Settings Port 1 Serial Port 2 ZigBee Accessible IP Settings Auto Warning Settings Upgrade Firmware Monitor Change Password Load Factory Default Save Restart NPort 23150 IP 192 168 35 101 MAC Address NPZ3150_20 Serial NO 20 Firmware Operation Modes l Port 1 Operation mode TCP alive check time Inactivity time 0 0 65535 ms Ono Oves Ignore jammed IP Destination IP address 1 Port 4001 o Destination IP address 2 Port 14001 Destination IP address 3 Port 14001 Destination IP address 4 Port 4001 Designated local port 1 5011 Designated local port 2 501 2 Designated local port 3 5013 Designated local port 4 5014 Connection control Startup None S Data Packing Packing length 0 0 1024 Delimiter 1 00 Hey Ll Enable Delimiter 2 00 Hex C Enable Delimiter process Do Nothing v Processed only when packing length is 0 Force transmit 0 Ko 65535 ms O Apply the above settings to all serial ports When Mode is set to TCP Client on a serial port s Operation Modes page you will be able to configure additional settings such as TCP alive check time Inactivity time and Ignore jammed IP
42. e of multiple units simultaneously if each unit is the Same model Hold down the CTRL to add additional units to your selection hold down the SHIFT key to select a block of units Linux Real TTY Drivers Real TTY driver are provided that will map Linux host TTY ports to NPort serial ports Once the mapping has been set up Linux users and applications can connect to a serial port as if it were a local TTY port These drivers have been designed and tested for the majority of Linux distributions including Linux kernel version 2 4 x 2 6 x and 3 x Please check http www moxa com for the latest Linux kernel support Basic Steps Follow these instructions to map a TTY port to a NPort serial port 1 Install the NPort device server and set the target device port to Real COM mode 2 Install the Real TTY driver files on the Linux host 3 Map the host s TTY port to the target device port on the NPort Installing Linux Real TTY Driver Files Before proceeding with the software installation make sure you have completed the NPort device server has been installed and configured correctly Note that the default LAN IP address for the NPort is 192 168 126 254 whereas the default WLAN IP address is 192 168 127 254 ATTENTION The target serial port must be operating in Real COM mode in order to map TTY ports Obtain the driver file from the Document and Software CD or from http www moxa com Log in to the console as a Super user root
43. eater the serial port s communication settings i e baudrate parity data bits etc will be determined by the NPort Any host that opens the COM port connection must use identical serial communication settings Ignore Jammed IP Default Disable Options Disable Enable Description This field specifies how an unresponsive IP address is handled when there are simultaneous connections to the serial port Disable All transmission will be suspended if one IP address becomes unresponsive Transmission will only resume when all hosts have responded Enable Data transmission to the other hosts will not be suspended if one IP address becomes unresponsive 5 16 NPort Z3150 Series Web Console Configuration Allow Driver Control Default Disable gt Options Disable Enable Description This field specifies how the port will proceed if driver control commands are received from multiple hosts that are connected to the port Disable Driver control commands will be ignored Enable Control commands will be accepted with the most recent command received taking precedence Connection Goes Down Default always high Options always low always high Description This field specifies what happens to the RTS and DTR signals when the Ethernet connection goes down For some applications serial devices need to know the Ethernet link status through RTS or DTR signals sent through the serial port Always low The selec
44. ecurity IPyb Settings ime The FIFO settings will ovenarite the firmware setting Tx Made HiPerformance FIFO Enable v Network Timeout 5000 ms 500 20000 Fast Flush Flush Local Butter Only M Auto Network Re Connectior Always Accept Open Requests Return Error If Network ls Unavailable M Cancel Tx Mode In Hi Performance mode the driver immediately issues a Tx Empty response to the program after sending data to the NPort In Classical mode the driver sends the Tx Empty response after confirmation is received from the NPort Classical mode is recommended if you want to ensure that all data is sent out before further processing FIFO This tells the driver whether or not to use the FIFO Network Timeout You can use this option to prevent blocking if the target NPort is unavailable Auto Network Re Connection With this option enabled the driver will repeatedly attempt to re establish the TCP connection if the NPort does not respond to background check alive packets Always Accept Open Requests When the driver cannot establish a connection with the NPort the user s software can still open the mapped COM port just like an onboard COM port Host gt t 4 Try Establish Connection f 4 A RealCOM mode Ethernet 3 Open COM port OK 7 9 NPort Z3150 Series Installing and Configuring the Software Return error if network is unavailable If this option is dis
45. endly method available to configure NPort Z3150 In this chapter we introduce the Web Console function groups and function definitions The following topics are covered in this chapter A 00 O0 O0 0 O02 0 0 0 0 02 0 0 0R 08 0R 02 00 0 0 Overview Quick Setup Export Import Basic Settings Network Settings SNMP Settings ZigBee Settings Security Settings Serial Settings gt Port 1 Operating Settings gt Port 1 or 2 Settings for RealCOM Mode Settings for TCP Server Mode Settings for TCP Client Mode Settings for UDP Mode UDP Multicast Accessible IP Settings Auto Warning Settings gt E mail and SNMP Trap gt E mail server Auto Warning Settings gt Event Settings Firmware Upgrade Change Password Load Factory Default Save Restart NPort Z3150 Series Web Console Configuration Overview This chapter introduces the NPort Web Console and explains how to configure the basic settings The NPort can be configured from anywhere on the network through its Web Console Simply point the browser to the device server s IP address to open the web console Network settings operation mode and other items can all be configured through the browser Web Browser Settings In order to use the web console you will need to have cookies ax enabled for your browser Please note that the web console uses General Security Content Connections Programs Advanced Select a Web content zone to specify ts security settings coo
46. erial NO 20 Firmware Step 1 3 Server Settings Server name NPZ3150_20 Network Settings IP settings Static Y IP address 192 168 35 101 Netmask 255 255 255 0 Gateway In Step 1 3 you must assign a valid IP address to the NPort Z3150 before it will work in your network environment Your network system administrator should provide you with an IP address and related settings for your network In addition the server name field is a useful way to specify the location or application of different NPort Z3150s lol Go 8 htip 192 168 127 254 wizard htm z 49 X E NPort web Console KA OX MN Total Solution for Industrial Device Networking WWW moxa com Model NPort Z3150 IP 192 168 127 254 MAC Address 00 90 E8 00 00 03 Name NPZ3150_3 Serial NO 3 Firmware 1 0 Build 11112915 Step 2 3 ZigBee Settings PAN ID 0000 0 0xFFFD Topology Mesh y Channel 11 Back nen TT In the Step 2 3 you can modify the ZigBee settings M OXN Total Solution for Industrial Device Networking Model NPort 23150 IP 192 168 35 101 MAC Address Name NPZ3150_20 Serial NO 20 Firmware Step 3 3 Operation Mode Settings O Real COM PC communicate with serial device through COM port Remember to install Real COM TTY driver on PC For detail information please refer to User s Manual Otcp PC communicate with serial device through TCP port Device is TCP c
47. es on Windows or Linux software that was originally designed for locally attached COM or TTY devices With this mode you can access your devices from the network using your existing COM TTY based software without investing in additional software Three different socket modes are available for user developed socket programs TCP Server TCP Client and UDP Server Client For TCP applications the appropriate mode depends on whether the connection will be hosted or initiated from the NPort serial port or from the network The main difference between the TCP and UDP protocols is that TCP guarantees delivery of data by requiring the recipient to send an acknowledgement to the sender UDP does not require this type of verification making it possible to offer speedier delivery UDP also allows multicasting of data to groups of IP addresses and would be suitable for streaming media or non critical messaging applications such as LED message boards Real COM Mode Real COM mode is designed to work with NPort drivers Real COM Mode that are installed on a network host COM drivers are provided for Windows systems and TTY drivers are 4 TPAR provided for Linux and UNIX systems The driver gt establishes a transparent connection to the attached serial device by mapping a local serial port to the NPort Proceed directly vath data transmission connection request not required serial port Real COM mode supports up to four simultaneous con
48. ese limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help CAUTION Any changes or modifications not expressly approved by the grantee of this device could void the user s authority to operate the equipment FCC RF Radiation Exposure Statement This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device
49. ew IP address Information es 1 Configuration is applied ok OK 7 15 NPort Z3150 Series Installing and Configuring the Software Upgrading NPort Firmware 1 Once NPort Search Utility has found NPort device servers on the LAN you can upgrade any unit s firmware Right click the desired NPort in the main window and select Upgrade f8 NPort Search Utility le FS Le EX Console Assign IP Ur Lock Ll parade NPort wd Th l Be is i 5 E Search Result 1 NPortis a 2 Select the new firmware file and click OK to proceed To obtain the latest firmware for the NPort Z3150 visit www moxa com E Upgrade file _ B xj Select Firmware File He pate O Browse K X Cancel 3 The utility will begin upgrading the firmware for the selected unit Do not disconnect or power off the unit while the firmware is being upgraded PS Upgrade Process O xj Processing please wal X Cancel MAC Address IP Address Status NPort 3150 00 30 5 00 00 03 192 166 355 112 Transmit 0 7 16 NPort Z3150 Series Installing and Configuring the Software 4 When the displayed status is OK click Close to complete the process fa Upgrade Process Oj xj Frocessing please wait HL Elose MAC Address IP Address Pelee NPort 3150 00 30 Es 00 00 03 192 766 395 112 ATTENTION NPort Search Utility supports upgrading the firmwar
50. feature helps the administrator manage how the NPort 23150 sends SNMP Trap to a pre defined SNMP Trap server when the enabled events such as Cold start Warm start Authentication failure etc occur To configure this feature click the Event Type Trap checkbox ATTENTION SNMP indicates a change in DCD or DSR signals but does not differentiate between the two A change in either signal from to is indicated by link up and a change in either signal from to is indicated by link down Firmware Upgrade NA OXN Total Solution for Industrial Device Networking www moxa com Model NPort Z3150 IP 192 168 35 101 MAC Address Name NPZ3150_20 Serial NO 20 Firmware Upgrade Firmware Main Menu Upgrade Local Device Overview Quick Setup Upgrade firmware y Browse Exportlmport Basic Settings Network Settings Zigbee Settings Serial Settings Operating Settings Accessible IP Settings Auto Warning Settings Upgrade Firmware Ch ye SSW Load Factory Default Save Restart The Firmware Upgrade page is where you can update the NPort firmware After obtaining the latest firmware from www moxa com select or browse for the firmware file in the Select firmware file field Before clicking Import it is a good idea to save the NPort configuration using the Import Export page since the firmware upgrade process may cause all settings to revert to factory defaults
51. gs tcpOutSegs tcpRetransSegs tcpConnState tcpConnLocalAddress snmpInTotalReqVars snmpInTotalSetVars snmpInGetRequests snmpInGetNexts snmpInSetRequests snmpInGetResponses snmpInTraps snmpOutTooBigs snmpOutNoSuchNames snmpOutBadValues Generic RS 232 like Group rs232Number RS 232 like General Port Table rs232PortTable rs232PortEntry rs232PortIndex RS 232 like Asynchronous Port Group rs232AsyncPortTable rs232AsyncPortEntry The Input Signal Table rs232InSigTable rs232InSigEntry rs232PortType rs232PortInSigNumber rs232PortOutSigNumber rs232AsyncPortIndex rs232AsyncPortBits rs232InSigPortIndex rs232InSigName tcpConnLocalPort tcpConnRemdAddress tcpConnRemPort tcpInErrs tcpOutRsts snmpOutGenErrs snmpOutGetRequests snmpOutGetNexts snmpOutSetRequests snmpOutGetResponses snmpOutTraps snmpEnableAuthenTraps rs232PortInSpeed rs232PortOutSpeed rs232AsyncPortStopBits rs232AsyncPortParity rs232InSigState NPort Z3150 Series SNMP Agents with MIB II amp RS 232 Like Groups The Output Signal Table rs2320utSigTable rs2320utSigPortIndex rs2320utSigState rs2320utSigEntry rs2320utSigName ZigBee Introduction ZigBee is a standard that defines a set of communication protocols for low data rate short range wireless networking ZigBee based wireless devices operate in 868 MHz 915 MHz and 2 4 GHz frequency bands The maximum data rate is 250 K bits per second ZigBee is utilized mainly for battery powe
52. h Utility to upgrade the firmware NPort Windows Driver Manager NPort Windows Driver Manager installs remote NPort serial ports as new COM ports on your Windows PC When the drivers are installed and configured devices that are attached to serial ports on the NPort will be treated as if they were attached to your PC s own COM ports The NPort serial port must be configured for Real COM mode when being mapped to a COM port Installing NPort Windows Driver Manager 1 The main installation window will open when you insert the Document amp Software CD Click INSTALL COM Driver to proceed Once the installation program starts running click Yes to proceed 2 The installation wizard will open Click Next to proceed is Setup NPort Windows Driver Manager o x Welcome to the NPort Windows Driver Manager Setup Wizard This will install MW Port Windows Driver Manager Werl 4 on your computer lt i recommended that you close all other applications before Continuing Click Nest to continue or Cancel to exit Setup Cancel 7 2 NPort Z3150 Series Installing and Configuring the Software 3 Select a destination directory and click Next to proceed ia Setup NPort Windows Driver Manager Select Destination Location Where should NPort Windows Driver Manager be installed ea AEE Select Start Menu Folder Where should Setup place the program s shortcuts NPort Windows Diver Manager 7 3 NPort Z
53. he Monitor Async is used to monitor the signal and data transmission status for the serial port TxCnt number of Tx packets to device for the current connection RxCnt number of Rx packets from device for the current connection TxTotalCnt number of Tx packets since the NPort was powered on RxTotalCnt number of Rx packets since the NPort was powered on 6 2 NPort Z3150 Series Monitor Async Settings Model Name Total Solution for Industrial Device Networking IP Serial NO 192 168 35 101 20 Firmware Web Console WWW MOX MAC Address 00 90 E8 00 00 20 1 0 Build 11090913 Main Menu Overview Quick Setup Exportlmport Basic Settings Network Settings Zigbee Settings Serial Settings Operating Settings Accessible IP Settings Auto Warning Settings Upgrade Firmware Monitor Line Asyne Asyne Settings ZigBee ZigBee Settings Change Password Monitor Async Settings Baud Rate Data Bits Stop Bits 1 115200 8 1 Flow Control Parity FIFO Interface RTSICTS XON XOFF DTRDSR None OFF OFF OFF Enable RS 232 Monitor The Monitor Async Settings page is used to view the current communication settings for the serial port Monitor ZigBee The ZigBee page is used to view the current status of ZigBee network connection NPort Web Console Windows Internet Explorer 3 Ss gt http 192 168 127 254 MOXA Model Name NPort 23150 IP NPZ3150_3 Serial NO Py 9
54. ial port s buffer will be packed including delimiters Delimiter 1 One additional character must be received before the data in the serial port s buffer is packed Delimiter 2 Two additional characters must be received before the data in the serial port s buffer is packed Strip Delimiter Data accumulated in the serial port s buffer will be packed but the delimiter character s will be stripped from the data 5 21 NPort Z3150 Series Web Console Configuration Force Transmit Default Joms o O Options 0to65535 Description This field controls data packing by the amount of time that elapses between bits of data When using this field make sure that Inactivity time is disabled or set to a larger value Otherwise the connection may be closed before the data in the buffer can be transmitted 0 If serial data is not received the NPort will wait indefinitely for additional data 1 to 65535 If serial data is not received for the specified amount of time the data that is currently in the buffer will be packed for network transmission The optimal force transmit time depends on your application but it must be at least larger than one character interval within the specified baudrate For example assume that the serial port is set to 1200 bps 8 data bits 1 stop bit and no parity In this case the total number of bits needed to send a character is 10 bits and the time required to transfer one character is 8 3 ms so th
55. ice 5 26 NPort Z3150 Series Web Console Configuration Packet Length Options 0to1024 Description This field specifies the maximum amount of data that is allowed to accumulate in the serial port buffer before sending O Packet length is disregarded and data in the buffer will be sent as specified by the delimiter settings or when the buffer is full 1 to 1024 Data in the buffer will be sent as soon it reaches the specified length Delimiter 1 and 2 Options Disabled Enabled 0x00 to OxFF Description These fields are used to define special delimiter character s for data packing Enable Delimiter 1 to control data packing with a single character enable both Delimiter 1 and 2 to control data packing with two characters received in sequence When these fields are enabled serial data will accumulate in the serial port s buffer until the buffer is full or until the specified delimiter character s are received For example the carriage return character could be used as a delimiter in order to transmit each sentence or paragraph in a separate packet Data will be packed according to Delimiter process Delimiters must be incorporated into the data stream at the software or device level ATTENTION When Delimiter 1 is enabled Packet length must be set to 0 Delimiter Process Options Do Nothing Delimiter 1 Delimiter 2 Strip Delimiter Description This field specifies how data is packed when delimiter cha
56. ich is not the ZigBee coordinator but may act as an IEEE 802 15 4 2003 coordinator within its personal operating space that is capable of routing messages between devices and upporting associations Network Topology The ZigBee network layer NWK supports star tree and mesh topologies In a star topology the network is controlled by one single device called the ZigBee coordinator The ZigBee coordinator is responsible for initiating and maintaining the devices on the network All other devices known as end devices directly communicate with the ZigBee coordinator In mesh and tree topologies the ZigBee coordinator is responsible for starting the network and for choosing certain key network parameters but the network may be extended through the use of ZigBee routers In tree networks routers move data and control messages through the network using a hierarchical routing strategy Tree networks may employ beacon oriented communication as described in the IEEE 802 15 4 2003 specification Mesh networks allow full peer to peer communication ZigBee routers in mesh networks do not currently emit regular IEEE 802 15 4 2003 beacons This specification describes only intra PAN networks that is networks in which communications begin and terminate within the same network In the star topology every device in the network can communicate only with the PAN coordinator A typical scenario in a star network formation is that an device programmed to be a PAN
57. iguring the NPort for the first time over an Ethernet cable you will use the default IP address 192 168 127 254 If prompted enter the console password You will only be prompted for a password if you have enabled password protection on the device server The password will be transmitted with MD5 encryption over the Ethernet 5 2 NPort Z3150 Series Web Console Configuration Password 000 ATTENTION If you have forgotten the password you can use the reset button to load factory defaults but this will erase all previous configuration information The web console will appear as shown below NA OXN Total Solution for Industrial Device Networking WWW MOX Model NPort 23150 IP 192 168 35 101 MAC Address 00 90 E8 00 00 20 Name NPZ3150_20 Serial NO 20 Firmware Welcome to NPort web console Main Menu Overview Quick Setup Exportimport Click Quick Setup to go through three simple steps making your NPort ready to F 4 Basic Settings Quick Setup work Network Settings Zigbee Settings Serial Settings E Click Exportmport to perform configuration backup or recovery Operating Settings Export Import Accessible IP Settings Auto Warning Settings Upgrade Firmware Monitor Change Password Load Factory Default Save Restart Settings are presented on pages that are organized by folder Select the desired folder in the left navigation panel to open that page The page will be displ
58. ime and Max connection TCP Alive Check Time Bera zmn Description This field specifies how long the NPort will wait for a response to keep alive packets before closing the TCP connection The NPort checks connection status by sending periodic keep alive packets 0 The TCP connection will remain open even if there is no response to the keep alive packets 1 to 99 If the remote host does not respond to the packet within the specified time the NPort will force the existing TCP connection to close Inactivity Time CAN Description This field specifies the time limit for keeping the connection open if no data flows to or from the serial device 0 The connection will remain open even if data is never received For many applications the serial device may be idle for long periods of time so O is an appropriate setting 1 to 65535 If there is no activity for the specified time the connection will be closed When adjusting this field make sure that it is greater than the Force transmit time Otherwise the TCP connection may be closed before data in the buffer can be transmitted 5 19 NPort Z3150 Series Web Console Configuration Max Connection Description This field specifies the maximum number of connections that will be accepted by the serial port 1 Only a single host may open the TCP connection to the serial port 2 to 8 This serial port will allow the specified number of connections to
59. ings 5 gt Operating settings 6 gt Accessible IP settings lt C gt Auto warning settings lt 8 gt Monitor lt 9 gt Ping lt a gt Change password lt b gt Load factory default Cv View settings lt s Save Restart Cq gt Quit Key in your selection 4 Input 1 to select IP address and press Enter cs Telnet 192 168 35 112 lt lt Main menu gt Network settings gt gt 1 gt IP address 2 gt Netmask 3 gt Gateway lt 4 IP configuration lt 5 gt DNS server 1 lt 6 gt DNS server 2 gt SNMP 8 gt SNMP community name lt 9 gt SNMP contact lt a SNMP location lt u gt View settings lt m gt Back to main menu lt a gt Quit Key in your selection 1 3 3 NPort Z3150 Series Initial IP Configuration 5 Key in your desired IP address and press Enter Key in your selection 1 IP address 192 163 127 254 Set IP address success Press any key to continue 6 Input m to go back main menu and press Enter lt lt Main menu gt Network settings 1 gt IP address 2 gt Netmask 3 gt Gateway 4 gt IP configuration lt 5 gt DNS server 1 lt 6 gt DNS server 2 7 gt SNMP 8 gt SNMP community name lt 9 gt SNMP contact lt a gt SNMP location Cv View settings lt m gt Back to main menu Cq gt Quit Key in your selection m 7 NPort 23156 MAC address 66 96 E8 66 66 63 Serial No 3 Firmware version 1 68 Build 11112915 System uptime 6
60. kies only for password transmission For Internet Explorer cookies can be enabled by right clicking the Internet Explorer icon on your desktop and selecting Properties from the context menu Local intranet Trusted sites Restricted sites Internet gt This zone contains all Web stes you E haven t placed in other zones Security level for this zone Move the slider to sst the security level or this zone Medium Safe browsing end still Functional Prompts before downloading potentially unsafe content Unsigned ActiveX controls will not be downloaded Appropriate for most Internet sites Custom Level ult Level On the Security tab click Custom Level and enable these two ax items Settings i Cookies ra Allow cookies that are stored on your computer a eee Allow per session cookies not stored es O Prompt iat Allow per session cookies not stored O Disable Enable Prompt ay Downloads a File download O Disable Enable BAY Cant dmrentn ad m Reset custom settings Reset to medium r Reset a con ATTENTION If you are not using Internet Explorer cookies are usually enabled through a web browser setting such as allow cookies that are stored on your computer or allow per session cookies Navigating the Web Console To open the web console enter your device server s IP address in the website address line If you are conf
61. king Enable Delimiter 1 to control data packing with a single character enable both Delimiter 1 and 2 to control data packing with two characters received in sequence When these fields are enabled serial data will accumulate in the serial port s buffer until the buffer is full or until the specified delimiter character s are received For example the carriage return character could be used as a delimiter in order to transmit each sentence or paragraph in a separate packet Data will be packed according to Delimiter process Delimiters must be incorporated into the data stream at the software or device level ATTENTION When Delimiter 1 is enabled Packet length must be set to 0 Delimiter Process Options Do Nothing Delimiter 1 Delimiter 2 Strip Delimiter Description This field specifies how data is packed when delimiter characters are received This field has no effect if Delimiter 1 is not enabled Do nothing Data accumulated in the serial port s buffer will be packed including delimiters Delimiter 1 One additional character must be received before the data in the serial port s buffer is packed Delimiter 2 Two additional characters must be received before the data in the serial port s buffer is packed Strip Delimiter Data accumulated in the serial port s buffer will be packed but the delimiter character s will be stripped from the data Force Transmit CA Description This fie
62. king bii Model NPort 23150 IP 192 168 MAC Address 00 90 E8 00 0 Name NPZ3150_2 Serial NO 20 Firmware 1 0 Build 110 E mail and SNMP Trap Settings Main Menu a A Mail Server Overview Quick Setup Mail server Exportlmport A O My server requires authentication Basic Settings Network Settings User name Zigbee Settings Password Bonal sil From E mail address NPZ3150_20 NPZ3150 Operating Settings E mail address 1 E mail address 2 E mail address 3 E mail address 4 Upgrade Firmware Monitor i SNMP Trap Server Line Async SNMP trap server IP or domain name Async Settings TinQan Cnatinac E The E mail Alert page is located under E mail and SNMP Trap in the Auto Warning Settings folder This is where you specify how and where e mail is sent when e mail is used for automatic notification of system and serial port events ATTENTION Consult your network administrator or ISP for the mail server settings to use for your network If these settings are not configured correctly e mail notification may not work properly Mail Server free text e g 192 168 3 3 Description This field specifies the IP address of the mail server that will be used when sending automatic warning e mails If the mail server requires authentication select My server requires authentication and enter the username and password From E mail Address Options _ free text e g jsmithOxyz com This field
63. ld controls data packing by the amount of time that elapses between bits of data When using this field make sure that Inactivity time is disabled or set to a larger value Otherwise the connection may be closed before the data in the buffer can be transmitted O If serial data is not received the NPort will wait indefinitely for additional data 1 to 65535 If serial data is not received for the specified amount of time the data that is currently in the buffer will be packed for network transmission The optimal force transmit time depends on your application but it must be at least larger than one character interval within the specified baudrate For example assume that the serial port is set to 1200 bps 8 data bits 1 stop bit and no parity In this case the total number of bits needed to send a character is 10 bits and the time required to transfer one character is 8 3 ms so the force transmit time to be larger than 8 3 ms 5 25 NPort Z3150 Series Web Console Configuration Settings for UDP Mode p A OXN Total Solution for Industrial Device Networking Model NPort 23150 IP 192 168 35 101 Name NPZ3150_20 Serial NO 20 Operation Modes Main Menu Port 1 Overview Quick Setup Operation mode CD Exportlmport sr End Port Basic Settings as Network Settings Destination IP address 1 an I ball Zigbee Settings Destination IP address 2 14001 Serial Settings Destination IP address 3 g
64. lient Destination IP address Port 4001 OunpP PC communicate with serial device through UDP port Destination IP address Port 4001 Baek O nen IET 5 4 NPort Z3150 Series Web Console Configuration In the Step 3 3 you must specify which operation mode you will use MO gt XN Total Solution for Industrial Device Networking me Model NPo 10 IP 192 168 MAC Address 00 90 E8 0 Name NPZ 20 Serial NO 20 Firmware 1 0 Build 1 Finish Settings Your changes have not been saved Please check that your settings in the following and click Save Restart for the updates to take effect or click Back to modi Basic Settings Server name NPZ3150_20 Network Settings IP settings Static IP 192 168 35 101 Netmask 255 255 255 0 Gateway Zigbee Settings PAN ID 0x0001 Topology Mesh Channel 11 Operation Mode Settings Mode RealCOM Parameters Review your settings at the Finish Settings page to confirm that they are correct and then click the Save Restart button to restart the device with the new settings NA OXN Total Solution for Industrial Device Networking Www me Model NPort 23150 IP 8 35 10 MAC Address 00 90 E8 00 00 20 Name NP2 20 Serial NO 20 Firmware 1 0 Build 11090913 Settings saved Restarting Note that if you changed the IP address you will not be able to return to the Home Page with the Home button Export Import Export Import allows you to
65. nections so multiple hosts can collect data from the attached device at the same time cra Coral bam XA gt 5 ATTENTION Real COM drivers are installed and configured through NPort Windows Driver Manager Real COM mode allows you to continue using your serial communications software to access devices that are now attached to your NPort device server On the host the NPort Real COM driver automatically intercepts data sent to the COM port packs it into a TCP IP packet and redirects it to the network At the other end of the connection the NPort device server accepts the Ethernet frame unpacks the TCP IP packet and sends the serial data to the appropriate device ATTENTION In Real COM mode several hosts can have simultaneous access control over the NPort serial port If necessary you can limit access by using the NPort s Accessible IP settings Please refer to Chapter 5 for additional information on Accessible IP settings 4 2 NPort Z3150 Series Introduction to Operation Modes TCP TCP Server Mode In TCP Server mode the NPort serial port is assigned an IP port address that is unique on your TCP IP network It waits for the host computer to establish a connection to the attached serial device This operation mode also supports up to four simultaneous connections so multiple hosts can collect data from the attached device at the same time Data transmission proceeds as follows 1 A host requests a co
66. ngs Time 2011 12 20 lo 54 53 Modify Operating Settings ai DSR Accessible IP Settings Auto Warning Settings Upgrade Firmware EE Monitor Web console Enable C Disable nce rcicnsoe eae Ca SavelRestart Reset button protect No C Yes On the Basic Settings page you can configure Server name Server location Time zone 24 hour Local time Time server and Console Settings Server Name Default NPz3150_ lt serial no gt Options free text e g Server 1 Description This is an optional free text field to help you differentiate one device server from another It does not affect operation of the NPort device server Time Zone Default GMT Greenwich Mean Time GMT Greenwich Mean Time GMT 01 00 Azores Cape Verde Is GMT 02 00 Mid Atlantic etc Description This field shows the currently selected time zone and allows you to select a different time zone 5 6 NPort Z3150 Series Web Console Configuration Local Time Defaut Options Date yy mm dd Time hh mm ss Description The NPort has a built in real time clock that allows you to add time information to functions such as the automatic warning e mail or SNMP trap This field shows the current time according to the NPort s built in real time clock This is not a live field so you will need to refresh the browser to get an updated reading Click Modify to adjust the real time clock Make sure that you first select the correct time z
67. nished installing WNPor Windows Driver Manager on pour computer The application may be launched by selecting the installed icons Click Finish to exit Setup Adding Mapped Serial Ports NPort Windows Driver Manager adds a COM port to your PC that is mapped to an NPort serial port The destination NPort serial port must be set to Real COM mode 1 In NPort Windows Driver Manager click Add on the main toolbar g NPort Windows Driver Manager File COM Manning Manning view Help AGD Exit move geen IP Address Command Port___ Mode App a 7 5 NPort Z3150 Series Installing and Configuring the Software 2 Click Search to search the network for NPort device servers In the list of NPort device servers that are found select the unit s that you will use for COM mapping and click OK Add NPort a fo Model a E PO IE IS O IO E E A A Y SA First Mapping Hort rro fo eet 50 Lommana Fort E 1 otal Farts Ho Alternatively you can select Input Manually and manually enter the NPort IP Address ist Data Port ist Command Port and Total Ports for the desired NPort unit Click OK to proceed Add NPort L Mapping PvE COM Port 132 168 127 204 7 6 NPort Z3150 Series Installing and Configuring the Software 3 NPort Windows Driver Manager will list each available serial port and will automatically assign a new COM port to each one The new COM port will n
68. nnection 1 Port 2 ZigBee Accessible IP Settings Auto Warning Settings Upgrade Firmware Monitor Change Password Load Factory Default Save Restart Click Operating Settings located under Main Menu to display the operating settings for both of NPort Z3150 s serial ports Port 1 is for serial port beside port 2 is for ZigBee port Settings for RealCOM Mode NA OXN Total Solution for Industrial Device Networking Model NPort 23150 IP 192 168 35 101 MAC Address Name NPZ3150_20 Serial NO 20 Firmware Operation Modes Main Menu e Port 1 Overview Operation mode RealCOM vw Quick Setup TCP alive check time El Exportlmport Basic Settings Max connection 1 Network Settings Ignore jammed IP No Yes Zigbee Settings Allow driver control No Yes Serial Settings Operating Settings a Data Packing Port 2 ZigBee Packing length 0 0 1024 Accessible IP Settings Delimiter 1 00 Hey C Enable Auto Warning Settings oe _ Delimiter 2 00 Hex C Enable Upgrade Firmware Monitor Delimiter process Do Nothing v Processed only when packing length is 0 Change Password Force transmit o 0 65535 ms Load Factory Default O Apply the above settings to all serial ports Save Restart When Mode is set to RealCOM on a serial port s Operation Modes page you will be able to configure additional settings such as TCP alive check time Max connection and Ignore jammed IP 5 15 NPort
69. nnection to the NPort serial port 2 Once the connection is established data can be transmitted in both directions from the host to the device and from the device to the host Client Mode In TCP Client mode the NPort actively establishes a TCP connection to a specific network host when data is received from the attached serial device After the data has been transferred the NPort can automatically disconnect from the host computer through the Inactivity time settings Please refer to Chapter 7 for details on these parameters Data transmission proceeds as follows 1 The NPort requests a connection from the host 2 The connection is established and data can be transmitted in both directions between the host and device UDP Mode UDP is similar to TCP but is faster and more efficient Data can be broadcast to or received from multiple network hosts However UDP does not support verification of data and would not be suitable for applications where data integrity is critical It is ideal for message display applications 4 3 TCP Server Mode 1 Request a connection 2 Proceed with data transmission Serial Dence TCP Client Mode 2 Proceed with Gata transission Serial Device Serial SE ALA UDP Mode Proceed directly with data transmission connection request not required J tH gt Web Console Configuration The Web Console is the most user fri
70. nsceiver UART 0 Ml LED Indicator Connecting the Hardware 12 48V Power jack ATTENTION Before connecting the hardware follow these important wiring safety precautions Disconnect power source Do not install or wire this unit or any attached devices with the power connected Disconnect the power before installation by removing the power cord before installing and or wiring your unit Follow maximum current ratings Calculate the maximum possible current in each power wire and common wire Observe all electrical codes dictating the maximum current allowable for each wire size If the current goes above the maximum ratings the wiring could overheat causing serious damage to your equipment Use caution unit may get hot The unit will generate heat during operation and the casing may feel hot to the touch Take care when handling unit Be sure to leave adequate space for ventilation The following guidelines will help ensure trouble free signal communication with the NPort e Use separate paths to route wiring for power and devices to avoid interference Do not run signal or communication wiring and power wiring in the same wire conduit The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together e If power wiring and device wiring paths must cross make sure the wires are perpendicular at the intersection point e Keep input wiring and output wiring separate e Label all wi
71. nsole Monitor 101 x int Us 93 Www moxa com MAC Address Firmware 00 90 E8 00 01 23 1 0 Build 12012015 Security 45 Disable The ZigBee Settings page is used to view the current status of the NPort Z3150 itself 6 4 7 Installing and Configuring the Software The following topics are covered in this chapter O Overview O NPort Windows Driver Manager gt Installing NPort Windows Driver Manager gt Adding Mapped Serial Ports gt Configuring Mapped Serial Ports O NPort Search Utility gt Installing NPort Search Utility gt Finding NPort Device Servers on Network gt Modifying NPort IP Addresses gt Upgrading NPort Firmware O Linux Real TTY Drivers gt Basic Steps gt Installing Linux Real TTY Driver Files gt Mapping TTY Ports gt Removing Mapped TTY Ports gt Removing Linux Driver Files O UNIX Fixed TTY Drivers gt Installing the UNIX Driver gt Configuring the UNIX Driver NPort Z3150 Series Installing and Configuring the Software Overview This chapter describes how to install and use NPort Windows Driver Manager NPort Search Utility and NPort Linux and UNIX drivers These items are located on the Document amp Software CD that is provided with the NPort Z3150 NPort Windows Driver Manager is a utility that installs and manages NPort COM drivers for COM mapping NPort Search Utility is a utility for the management of NPort device servers over the network You may also use NPort Searc
72. ole to Assign IP Ares ad 3 3 As Introduction to Op ration MOGESS iS 4 1 OW CIVIC Waaier A A E cae snes ncn neem e een ee 4 2 RECONTO O isis 4 2 POP Se VC MOC cio 4 3 TOP CHERUMOd Sinatra dada dodo dd dodo oro nina 4 3 UID PF MOG A 4 3 5 Web CONSOIS Con AAA A 5 1 OMe WEONES DTO ESAS T CRETE TET TERETE TREE TCE SOECES ESAS ENEE AENA ERAS OCIO 5 2 Web Browser Setas da 5 2 Navigating the Wen Console O eR Sa On 5 2 SU A In III eo en RO nL ee ee nO ee ee ee 5 3 EXPO ENPO E ea 5 5 Basic Sonda liinda dd dad ddr dd nd deen cee eats 5 6 A A O E TN 5 6 TIM LM 5 6 Local Timer rta E T too bala N TOE EE OT E O ne 5 7 TI AAA A A AO O E 5 7 Web CON O a atasatusa teuntarteraiasa tora tacateradera tata fodareca doit teca dato cebada tocata torta aatand 5 7 TEMCWCONSOIS ita aso 5 8 Reset Button Protect dd da tex 5 8 NetWork SENOS crara eor AAO dnav snes haar dra dar Suey beat anor dnarhnor dear dal Saar beai dou drat hnas dear Dro rea 5 8 PEO IQUITOS Ann mene al niin in ARE ner 5 9 TPS EES ne ert ne An 5 9 Netas Kiara AA AS A A AS A A A AS 5 9 GENOV aera alata a aoa aos ia a tv ie a en oe ea a ee a oat eee ee as 5 10 DNS Se NeT A a E auced aan eadeeneadeandenenane EE 5 10 SNMP Se TURNO Stata dra E AA a 5 10 SNMPV Loud bb iba 5 10 Aa A II AAA 5 10 COntacta nana O aos 5 11 LOCA O EEE EE EEE aa 5 11 DIS 2 UOC RANA SAA AAA AAA tal 5 11 PAN TD ritirarsi E E a ciica a E 5 11 TOPICO 5 11 Cane eera eht Geen ence cl humor eae O cena ceruemnnmec menor nen es
73. on will only be closed manually Any Character None The connection will be opened as soon as a character is received from the attached device The connection will only be closed manually Any Character Inactivity Time The connection will be opened as soon as a character is received from the attached device The connection will be closed if no data is received for the time specified in Inactivity time DSR On DSR Off The TCP connection is opened when the DSR signal is on and closed when the DSR signal is off DSR On None The TCP connection is opened when the DSR signal is on The connection will only be closed manually DCD On DCD Off The TCP connection is opened when the DCD signal is on and closed when the DCD signal is off DCD On None The TCP connection is opened when the DCD signal is on The connection will only be closed manually Packet Length Options Oto1024 Description This field specifies the maximum amount of data that is allowed to accumulate in the serial port buffer before sending O Packet length is disregarded and data in the buffer will be sent as specified by the delimiter settings or when the buffer is full 1 to 1024 Data in the buffer will be sent as soon it reaches the specified length 5 24 NPort Z3150 Series Web Console Configuration Delimiter 1 and 2 Options Disabled Enabled 0x00 to OxFF Description These fields are used to define special delimiter character s for data pac
74. one The real time clock will be updated immediately with no need to restart the NPort 1 Time Settings Mozilla Firefox KB htip n 192 168 235 101 Aine htm Modify time settings Date yy mm dd Time hh mm ss 2012 10 hits 4 150 140 ATTENTION There is a risk of explosion if the real time clock battery is replaced incorrectly The real time clock is powered by a lithium battery We strongly recommend that you obtain assistance from a Moxa support engineer before replacing the battery Please contact the Moxa RMA service team if you need to change the battery Time Server Options IP address or domain name e g 192 168 1 1 or time nist gov Description This optional field specifies your time server s IP address or domain name if a time server is used in your network The NPort supports SNTP RFC 1769 for automatic time calibration The device server will request time information from the specified time server every 10 minutes Web Console Default Enable Options Enable or Disable Description The Disable option for Web Console is included for security reasons In some cases you may want to disable one or both of these console utilities as an extra precaution to prevent unauthorized users from accessing your NPort Z3150 The factory default for Web console is Enable 9 7 NPort Z3150 Series Web Console Configuration Telnet Console etau enable O
75. ot be accessible by the host system until it has been activated in NPort Windows Driver Manager Activating a mapped COM port saves the information in the host system registry and makes the COM port available for use Click Yes to activate the COM port s at this time click No to activate the COM port s later NPod Windows Driver Manager File COM Mapping View Help fal mom A a amp a Exit Add Remove Apply Undo Seting COM Port IP Address lia Information J66 a J67 4 For each mapped COM port that is activated you may see a message indicating that the software has not passed Windows Logo certification Click Continue Anyway to proceed Hardware Installation E l A The software you are installing for this hardware NPor Communication Port 1 has not passed Windows Logo testing to verify its fit with Windows XP Tell me why this testing i Continuing your installation of this software may impair either immediately or in the future Microsoft strongly that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing Continue Anyway STOP Installation 5 Activated COM ports will be listed in black COM ports that have not been activated will be listed in blue Once a COM port has been activated the host computer will be able to communicate with the new COM port as if it were physically attached Since the COM mappings are sto
76. ptions Enable or Disable Description The Disable option for Telnet Console is included for security reasons In some cases you may want to disable one or both of these console utilities as an extra precaution to prevent unauthorized users from accessing your NPort Z3150 The factory default for Telnet console is Enable ATTENTION If you disable both the Web console and Telnet console you can still use NPort Administrator to configure NPort Z3150 device servers either locally or remotely over the network Refer to Chapter 7 for more details Reset Button Protect Options YesorNo ss Description Select the Yes option to allow limited use of the Reset Button In this case the Reset Button can be used for only 60 seconds I e 60 seconds after booting up the Reset Button will be disabled automatically Network Settings MO gt XN Total Solution for Industrial Device Networking Model MPort 23150 IP 192 168 355 101 Name NFPZ3150_20 Serial NO 20 Network Settings Main Menu l Network Settings Overview Quick Setup IP address 192 168 395 101 Exportlmport aS ee Netmask 255 255 255 0 Basic Setting i IP configuration Static M Serial Settings DNS server 1 f Operating Settings DNS server 2 Accessible IP Settings Auto Warning Settings SNMP Settings Upgrade Firmware Monitor SNMPv1 Enable Disable Change Password p Community name public Load Fac
77. racters are received This field has no effect if Delimiter 1 is not enabled Do nothing Data accumulated in the serial port s buffer will be packed including delimiters Delimiter 1 One additional character must be received before the data in the serial port s buffer is packed Delimiter 2 Two additional characters must be received before the data in the serial port s buffer is packed Strip Delimiter Data accumulated in the serial port s buffer will be packed but the delimiter character s will be stripped from the data 5 27 NPort Z3150 Series Web Console Configuration Force Transmit CAN Description This field controls data packing by the amount of time that elapses between bits of data When using this field make sure that Inactivity time is disabled or set to a larger value Otherwise the connection may be closed before the data in the buffer can be transmitted O If serial data is not received the NPort will wait indefinitely for additional data 1 to 65535 If serial data is not received for the specified amount of time the data that is currently in the buffer will be packed for network transmission The optimal force transmit time depends on your application but it must be at least larger than one character interval within the specified baudrate For example assume that the serial port is set to 1200 bps 8 data bits 1 stop bit and no parity In this case the total number of bits needed to send a ch
78. red applications where low data rate low cost and long battery life are main concerns In many ZigBee applications the total time the wireless device is engaged in any type of activity is very limited the device spends most of its time in a power saving mode also known as sleep mode As a result ZigBee enabled devices are capable of being operational for several years before their batteries need to be replaced One application of ZigBee is in home patient monitoring A patient s blood pressure and heart rate for example can be measured by wearable devices The patient wears a ZigBee device that interfaces with a sensor that gathers health related information such as blood pressure on a periodic basis Then the data is wirelessly transmitted to a local server such as a personal computer inside the patient s home where initial analysis is performed Finally the vital information is sent to the patient s nurse or physician via the Internet for further analysis The following topics are covered in this appendix O Device Type O Network Topology NPort Z3150 Series ZigBee Introduction Device Type The ZigBee standard uses slightly different terminology ZigBee coordinator an IEEE 802 15 4 2003 PAN coordinator ZigBee end device an IEEE 802 15 4 2003 RFD or FFD participating in a ZigBee network which is neither the ZigBee coordinator nor a ZigBee router ZigBee router an IEEE 802 15 4 2003 FFD participating in a ZigBee network wh
79. red in the host system registry they will still be in effect if the PC is restarted or if NPort Windows Driver Manager is closed e NPod Windows Driver Manager File COM Mapping View Help F i if l Exit d Remove TE COM12 192 168 85 72 351 367 aa Setting 2 7 NPort Z3150 Series Installing and Configuring the Software Configuring Mapped Serial Ports 1 To modify the settings of a mapped serial port select the desired port s and click Setting on the main toolbar e WPort Windows Driver Manager File COM Mapping View Help ir rn mh A E Exit d Remove Apply Unk gt A A AAA Command Port 92 165 8 42 950 COMI E 132168 72 351 967 r pun 2 On the Basic Setting tab select the COM Number that will be assigned to the serial port If you have selected multiple ports you can assign COM numbers automatically in sequential order by selecting the Auto Enumerating function 4 COM Port Setting loj x Port Number 1 Port s Selected 1st port is Port 1 Basic Settings Advanced Settings Serial Parameters Security COM Number coma current fin use Auto Enumerating LOM Number for a Selected Parts 7 8 NPort Z3150 Series Installing and Configuring the Software 3 On the Advanced Setting tab configure Tx Mode FIFO and Fast Flush Port Number 1 Port s are Selected Basic Settings Advanced Settings Serial Parameters S
80. rial NO 3 Firmware 1 0 Build 11112915 Main Menu PAN Settings Overview Quick Setup PAN ID 0000 0 0xFFFD A Channel 11 7 Basic Settings z Topology Mesh y Network Settings ZigBee Settings Output Power 45 al dBm Serial Settings Operating Settings Advanced Settings Accessible IP Settings f Mode Transparent Auto Warning Settings Upgrade Firmware Start Byte 2 3 Hex Monitor Change Password Security Settings Load Factory Default Save Restart Encryption Decryption Disable y AES 128 bits Key Hex zi On the ZigBee page is used to modify ZigBee settings such as PAN ID Channel and Topology PAN ID Default 0000 Options 0 to OxFFFD Hex The PAN identifier Topology Deau mes Options Star Tree and Mesh Network topology supports three kinds of topology Star Tree and Mesh 5 11 NPort Z3150 Series Web Console Configuration Channel CAN The 2 4GHz channel The range is from 11 to 26 Output Power Supports 20 16 12 8 4 1 5 1 4 5 dBm The output from power side Advanced Settings Advanced Advanced Settings na Mode TransparentorAddressable or Addressable Description Transparent All data comes to the Coordinator via the Ethernet port the Coordinator will broadcast to the desired ZigBee node Addressable All data with specified frame format that comes to the Coordinator will be sent directly to the desired ZigBee node
81. ring to each device in the system for easier testing and troubleshooting 2 4 NPort Z3150 Series Getting Started Connecting to the Network Use the supplied Ethernet cable to connect the NPort to your Ethernet network If the cable is properly connected the NPort will indicate a valid connection to the Ethernet as follows e A green Ethernet LED indicates a valid connection to a 100 Mbps Ethernet network e An orange Ethernet LED indicates a valid connection to a 10 Mbps Ethernet network e A flashing Ethernet LED indicates that Ethernet packets are being transmitted or received Connecting the Power Connect the VDC power line 12 to 48 V to the NPort s power jack or terminal block If power is properly connected the Ready LED will initially glow red When the system is ready the Ready LED will turn green Connecting to a Serial Device Use a serial cable to connect your serial device to a serial port on the NPort 225 3 Initial IP Configuration The following topics are covered in this chapter O O O O Overview Factory Default IP Settings Using ARP to Assign 1P Address Using the Telnet Console to Assign IP Address NPort Z3150 Series Initial IP Configuration Overview This chapter presents several ways to assign the NPort s IP address for the first time Please refer to Chapter 2 for instructions on connecting to the network The web console is the recommended method for configuring the
82. s for the IP address of the gateway if applicable A gateway is a network computer that acts as an entrance to another network Usually the computers that control traffic within the network or at the local Internet service provider are gateway nodes The NPort device server needs to know the IP address of the default gateway computer in order to communicate with the hosts outside the local network environment Consult your network administrator if you do not know how to set this parameter DNS Server 1 and 2 Options IP address e g 192 168 1 1 Description This field is for the DNS server s IP address if applicable With the DNS server configured the NPort device server can use domain names instead of IP addresses to access hosts Domain Name System DNS is how Internet domain names are identified and translated into IP addresses A domain name is an alphanumeric name such as www moxa com that it is usually easier to remember than the numeric IP address A DNS server is a host that translates a text based domain name into an IP address in order to establish a TCP IP connection When the user wants to visit a particular website the user s computer sends the domain name e g www moxa com to a DNS server to request that website s numeric IP address When the IP address is received from the DNS server the user s computer uses that information to connect to the website s web server The NPort will play the role of a
83. s how to connect the hardware Panel Layout 26mm 1 02 in O E h V V 10 100M Reset p L 12 48 VDC Ethernet 34 mm 1 34 in ZigBee to Ethernet Gateway 43 mm 1 69 in 111 mm 4 37 in RS 232 422 485 77 mm 3 33 in iE 26 mm 1 02 in 88 mm 3 46 in 100 mm 3 94 in LED Indicators Top Panel LED Indicators There are three LEDs on NPort Z3150 Ready Green On System power on Blinking 1 Device locating 2 Pull down the reset button Faut Red On System initialization failed ZigBee Green On ZigBee initialized PAN connection normal Blinking ZigBee Tx Rx Off ZigBee initial PAN connection failure Serial data output to serial port Serial data input from serial port 2 2 NPort Z3150 Series Getting Started End Panel LED Indicators Name Color Function ss Orange Ethernet Orange 10 Mbps Ethernet connection 100 Mbps Ethernet connection Ethernet cable is disconnected or has a short Pull High Low Resistors for RS 422 485 You may need to set the pull high low resistors when termination resistors are used for certain RS 422 or RS 485 environments ATTENTION Do not use the 1 KQ setting while in RS 232 mode Doing so will degrade the RS 232 signals and reduce the effective communication distance 2 3 NPort Z3150 Series Getting Started Function Block Connector TI CC2530 LAN Connector RS 232 422 485 Tra
84. specifies the e mail address that will be listed in the e mail s From field SNMP Trap Server IP Default Options IP address e g 192 168 5 5 This field specifies the IP address of the SNMP trap server that will receive SNMP traps 5 30 NPort Z3150 Series Web Console Configuration Auto Warning Settings gt Event Settings MO gt XN Total Solution for Industrial Device Networking Model NPort 23150 IP 192 168 35 101 MAC Address Name NPZ3150_20 Serial NO 20 Firmware Event Settings Main Menu System Event Overview Quick Setup Cold start O mail LI Trap Exportlmport ciedad Warm start O mail OTrap Basic Settings Network Settings Zigbee Settings Config Event Serial Settings Authentication failure C Mail O Trap Operating Settings O IP changed i Accessible IP Settings B Mal Auto Warning Settings Password changed C mail E mailand SNMP Trap DCD Changed Port 1 O mail CI Trap Monitor Change Password DSR Changed Load Factory Default Save Restart Port 1 C Mail O Trap The Event Settings page is located under Event Settings in the Auto Warning Settings folder This is where you specify how the NPort will notify you of system and configuration events Depending on the event different options for notification are available as shown above Mail refers to sending an e mail to a specified address Trap refers to sending an SNMP trap Event Description Cold start The NPort was
85. sume that the serial port is set to 1200 bps 8 data bits 1 stop bit and no parity In this case the total number of bits needed to send a character is 10 bits and the time required to transfer one character is 8 3 ms so the force transmit time to be larger than 8 3 ms 5 18 NPort Z3150 Series Web Console Configuration Settings for TCP Server Mode NA OXN Total Solution for Industrial Device Networking Model NPort Z3150 IP 192 168 35 101 Name NPZ3150_20 Serial NO 20 Operation Modes Main Menu a Port 1 Overview Quick Setup Operation mode TCP Server v Exportlmport eee TCP alive check time 7 0 99 min Basic Settings Network Settings Inactivity time 0 0 65535 ms Zigbee Settings Max connection E vi Serial Settings Ignore jammed IP No Yes Operating Settings Allow driver control No Yes Port 1 Serial CRSA o Local TCP port 14001 Pont 2 ZigBee Accessible IP Settings Command port 966 Auto Warning Settings Upgrade Firmware Data Packing Monitor Packing length 0 0 1024 Change Password dra Deian Delimiter 1 00 Hex C Enable Save Restart Delimiter 2 100 Hex CI Enable Delimiter process Do Nothing Processed only when packing length is 0 Force transmit 0 o 65535 ms O Apply the above settings to all serial ports When Mode is set to TCP Server on a serial port s Operation Modes page you will be able to configure additional settings such as TCP alive check time Inactivity t
86. t Z3150 Series Installing and Configuring the Software Configuring the UNIX Driver Modify the configuration The configuration used by moxattyd is defined in the text file moxattyd cf which is in the same directory You may use vi or any text editor to modify the file as follows ttyp1 192 168 1 1 950 You can refer to moxattyd cf for detailed descriptions of the various configuration parameters Please note that Device Name depends on the OS See the Device Naming Rule section in README TXT for more information To start the moxattyd daemon after system bootup add an entry into etc inittab using the TTY name you defined in moxattyd cf as in the following example ts 2 respawn usr etc moxattyd moxattyd t 1 Device naming rule For UnixWare 7 UnixWare 2 1 x and SVR4 2 use pts n For all other UNIX operating systems use ttyp n The value of n should be equal or larger than 11 in order to prevent conflicts with the device names of functional keys in some UNIX systems Starting moxattyd Execute the command init q or reboot your UNIX operating system Adding an additional server Modify the text file moxattyd cf to add an additional server User may use vi or any text editor to modify the file For more configuration information refer to moxattyd cf which contains detailed descriptions of the various configuration parameters Find the process ID PID of the moxattyd ps ef grep moxattyd Update the config
87. ted signal will change to low when the Ethernet connection goes down Always high The selected signal will remain high when the Ethernet connection goes down Packet Length Options Oto1024 Description This field specifies the maximum amount of data that is allowed to accumulate in the serial port buffer before sending O Packet length is disregarded and data in the buffer will be sent as specified by the delimiter settings or when the buffer is full 1 to 1024 Data in the buffer will be sent as soon it reaches the specified length Delimiter 1 and 2 Options Disabled Enabled 0x00 to OxFF Description These fields are used to define special delimiter character s for data packing Enable Delimiter 1 to control data packing with a single character enable both Delimiter 1 and 2 to control data packing with two characters received in sequence When these fields are enabled serial data will accumulate in the serial port s buffer until the buffer is full or until the specified delimiter character s are received For example the carriage return character could be used as a delimiter in order to transmit each sentence or paragraph in a separate packet Data will be packed according to Delimiter process Delimiters must be incorporated into the data stream at the software or device level ATTENTION When Delimiter 1 is enabled Packet length must be set to 0 9 17 NPort Z3150 Series Web Console Configuration
88. the tree and do not participate in message routing ZigBee routers can grow the network beyond the initial network established by the ZigBee coordinator Note this section refers to the book ZigBee Wireless Networks and Transceivers B 3 C Well Known Port Numbers Listed below are Well Known Port Numbers that may cause network problems if they are assigned to an NPort serial port Refer to RFC 1700 for Well Known Port Numbers or refer to the following introduction from IANA The port numbers are divided into three ranges Well Known Ports Registered Ports and Dynamic and or Private Ports e Well Known Ports range from O through 1023 e Registered Ports range from 1024 through 49151 e Dynamic and or Private Ports range from 49152 through 65535 The Well Known Ports are assigned by IANA and on most systems can only be used by system processes or by programs executed by privileged users The following table shows famous port numbers among the well known port numbers For more details please visit the IANA website at http www iana org assignments port numbers ree COM CNN CO TATTOO 213 IPX 160 to 223 Reserved for future use NPort Z3150 Series Well Known Port Numbers ENO Any private printer server EsZ D Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules Th
89. tor ZigBee OuUdad da Monitor ZigBee Settings NPort Z3150 Series Web Console Monitor Overview This chapter explains how to use the Monitor functions on the NPort web console These functions allow you to monitor many different aspects of operation Monitor Line MOXA Total Solution for Industrial Device Networking Model NPort 23150 IP j 35 101 MAC Address 00 90 E8 00 0 Name NPZ3150_20 Serial NO 20 Firmware 1 0 Build 1109 Main Menu Monitor Line Overview Quick Setup Port Operation Mode Connections Exportimport Basic Settings 1 RealCOM Listen O Network Settings l o l Listen Zigbee Settings 2 RealCOM Serial Settings Operating Settings Accessible IP Settings Auto Warning Settings Upgrade Firmware Async Settings The Monitor Line page is used to monitor the current operation mode and host connection status for each port Monitor Async KA OXN Total Solution for Industrial Device Networking WWW MOXz3 Model NP O 50 IP 192 168 3 MAC Address 00 90 E8 0 Name NPZ3150_20 Serial NO 2 Firmware 1 0 Build 1 Main Menu Monitor Async Overview Quick Setup Port TxCnt RxCnt TxTotalCnt RxTotalCnt DSR DTR RTS CTS DCD Exportlmport Basic Settings Network Settings Zigbee Settings Serial Settings Operating Settings Accessible IP Settings Auto Warning Settings Upgrade Firmware Monitor ZigBee ZigBee Settings T
90. tory Default saveiRestar Contact Po You can modify IP configuration IP address Netmask Gateway Speed and SNMP settings You must assign a valid IP address to the NPort before it will work in your network environment Your network system administrator should provide you with an IP address and related settings for your network The IP address must be unique within the network otherwise the NPort will not have a valid connection to the network First time users should refer to Chapter 3 Initial IP Address Configuration for more information 5 8 NPort Z3150 Series Web Console Configuration IP Configuration Default Static S O Options Static DHCP DHCP BOOTP BOOTP Description This field determines how the NPort s IP address will be assigned Static IP address netmask and gateway are user defined DHCP IP address netmask gateway DNS and time server are assigned by DHCP server DHCP BOOTP IP address netmask gateway DNS and time server are assigned by DHCP server IP address is assigned by BOOTP server if DHCP server does not respond BOOTP IP address is assigned by BOOTP server ATTENTION In Dynamic IP environments the firmware will retry 3 times every 30 seconds until network settings are assigned by the DHCP or BOOTP server The Timeout for each try increases from 1 second to 3 seconds to 5 seconds If the DHCP BOOTP Server is unavailable the firmware will use the default IP address 192 16
91. unload the driver Enter the directory usr lib npreal2 driver and execute mxuninst to uninstall the driver This program will perform the following actions 1 Unload the driver 2 Delete all files and directories in usr lib npreal2 3 Delete directory usr lib npreal2 4 Modify the system initializing script file UNIX Fixed TTY Drivers A fixed TTY driver is provided that will map UNIX host TTY ports to NPort serial ports Once the mapping has been set up UNIX users and applications can connect to an NPort serial port as if it were a local TTY port This driver has been designed and tested for the majority of UNIX systems Please check http www moxa com for the latest UNIX systems support Installing the UNIX Driver 1 Log into UNIX and create a directory for the MOXA TTY To create a directory named usr etc execute the command mkdir p usr etc 2 Copy moxattyd tar to the directory you created For the usr etc directory you would execute the following commands cp moxattyd tar usr etc cd usr etc 3 Extract the source files from the tar file by executing the command tar xvf moxattyd tar The following files will be extracted README TXT moxattyd c source code moxattyd cf an empty configuration file Makefile makefile VERSION TXT fixed TTY driver version FAQ TXT 4 Compile and link For SCO UNIX make sco For UnixWare 7 make svr5 For UnixWare 2 1 x SVR4 2 make svr42 7 19 NPor
92. uration of moxattyd kill USR1 PID e g if moxattyd PID 404 kill USR1 404 This completes the process of adding an additional server 7 20 A SNMP Agents with MIB II RS 232 Like Groups The NPort has built in SNMP Simple Network Management Protocol agent software that supports SNMP Trap RFC1317 RS 232 like groups and RFC 1213 MIB II The following table lists the standard MIB II groups as well as the variable implementation for the NPort The following topics are covered in this appendix O RFCi213 MIB II Supported SNMP Variables gt System MIB Interfaces MIB IP MIB ICMP MIB UDP MIB Address Translation TCP MIB SNMP MIB O RFC1317 RS 232 MIB Objects Generic RS 232 like Group RS 232 like General Port Table RS 232 like Asynchronous Port Group Y Y VV Y Y WV The Input Signal Table The Output Signal Table Y Y V WV NPort Z3150 Series SNMP Agents with MIB II amp RS 232 Like Groups RFC1213 MIB II Supported SNMP Variables System MIB SysDescr SysObjectID SysUpTime Interfaces MIB itNumber ifindex ifDescr ifType ifMtu ifSpeed ifPhysAddress ifAdminStatus IP MIB ipForwarding ipDefaultTTL ipInreceives ipInHdrErrors ipInAddrErrors ipForwDatagrams ipInUnknownProtos ipInDiscards ipInDelivers ipOutRequests ICMP MIB IcmpInMsgs IcmpInErrors IcmpInDestUnreachs IcmpInTimeExcds IcmpInParmProbs IcmpInSrcQuenchs IcmpInRedirects IcmpInEchos IcmpInEchoReps U
93. ure data access with AES e Dual power inputs 1 power jack and 1 terminal block 1 2 NPort Z3150 Series Introduction Product Specifications ZigBee Interface RF Standard 802 15 4 Frequency Band 2 4 GHz Interface Immunity DSSS RF Data Rate 250 Kbps Rx sensitivity 96 dBm Tx Power 4 5 dBm Max Transmission Distance Up tp 100m in open areas Antenna 2dB PAN ID 0x0000 OxFFFD Node ID O 99 RF Channel 11 26 16 channels Device Type Coordinator Network Topology Star Mesh Tree Security 128 bit AES encryption algorithms Ethernet Interface Number of Ports 1 Speed 10 100 Mbps auto MDI MDIX Connector RJ45 Magnetic Isolation Protection 1 5 KV built in Serial Interface Number of Port 1 Serial Standards RS 232 422 485 Connector DB9 male RS 485 Data Direction Control ADDC Automatic Data Direction Control Serial Communication Parameters Data Bits 5 6 7 8 Stop Bits 1 1 5 2 Parity None Even Odd Space Mark Flow Control RTS CTS XON XOFF DTR DSR Baudrate 50 bps to 921 6Kbps Serial Signals RS 232 TxD RxD RTS CTS DTR DSR DCD GND RS 422 TxD TxD RxD RxD GND RS 485 4w TxD TxD RxD RxD GND RS 485 2w Data Data GND Software Configuration Method Web Console Firmware Upgrade Web Console or Search Utility Hardware DIP Switch inside the box SW1 2 Pull high low resister SW3 Termination for RS 422 485 Reset Button Reset to default Physical Characteristics Weight 38
94. ver In general case you can ignore these settings Baud Rate seno y Parity None y Data Bits la y Stop Bits hoo w Flow Control None y 7 10 NPort Z3150 Series Installing and Configuring the Software 5 On the Security tab select the Enable Data Encryption option to enable data to be encrypted when transmitted over the COM ports After selecting the encryption option select the Keep connection option to start encrypting COM port communications immediately without restarting the COM ports This may speed up opening and closing of the COM port for your host but it also causes your host to tie up the NPort serial port so other hosts cannot use it 4 COM Port Setting 0 x Port Number 1 Port Selected 1st port is Port 1 Basic Settings Advanced Settings Serial Parameters Securty Apply All Selected Parts Enable Data Encryption Keep connection 6 Click OK when you have finished configuring the COM port 7 To save all COM mapping settings to a text file select Export in the context menu After the settings have been exported to a file they can be imported on another host gt NPort Windows Driver Manager Ek E File LUM Mapping Configuration View Help Fu Add Ctrl N El Ex gm Remove CtdD setting Mo l Ee 1 Address 2 Se Cth ia Setting 1689 33 19 950 966 Port je oes Re 2 1168 33 18 391 367 Porte 2 Z Import 7 11 NPort Z3150 Series Installing and Configuring
95. verview Be aware that previous settings will be lost Quick Setup Exportlmport a Basic Settings Network Settings Zigbee Settings Serial Settings Operating Settings Accessible IP Settings Auto Warning Settings Upgrade Firmware Monitor Change Password Load Factory Default D733 NPort Z3150 Series Web Console Configuration The Load Factory Default page is used to recovery default settings Click Submit to reset all settings to the factory defaults Save Restart MO gt XN Total Solution for Industrial Device Networking Model NPort 23150 IP 192 168 35 101 Name NPZ3150_20 Serial NO 20 Save Restart Main Menu 1 The configuration has been changed Please clickto reboot with new configuration Overview Quick Setup Warning Reboot will disconnect both serial and Ethernet connections and data maybe lost Exportilmport Basic Settings Network Settings Zigbee Settings Serial Settings Operating Settings Accessible IP Settings Auto Warning Settings Upgrade Firmware Monitor Change Password The Save Restart page is used to save configuration settings and then reboot device Click Submit to save configuration settings into device and then restart the NPort All new settings will be applied after device restarts 5 34 6 Web Console Monitor The following topics are covered in this chapter Overview Monitor Line Monitor Async Monitor Async Settings Moni
96. xx In this example 192 168 200 100 is the new IP address that will be assigned to the NPort and 00 90 E8 xx xx xx is the NPort s MAC address From the DOS prompt execute a special Telnet command using port 6000 as in the following example telnet 192 168 200 100 6000 In this example 192 168 200 100 is the new IP address that will be assigned to the NPort You should see a message indicating that the connection failed Connect failed The NPort will automatically reboot with the new IP address You can verify that the configuration was successful by connecting to the new IP address with Telnet ping the web console or NPort Search Utility 3 2 NPort Z3150 Series Initial IP Configuration Using the Telnet Console to Assign IP Address 1 Select Command Prompt from Accessories Accessories Bluetooth File Transfer E Calculator Command Prompt a3 Connect to a Network Projector ES Connect to a Projector Getting Started a Math Input Panel 2 Paint Hoy E Remote Desktop Connection 73 Run PIi n 3 i 1 2 Enter telnet 192 168 127 254 the NPort s default IP address and click OK cx C Windows system32 cmd exe C gt telnet 192 168 127 254 NPort 23156 66 96 E8 66 66 63 s 3 Firmware version 1 6 Build 11112915 System uptime days BBh 0m B5s lt lt Main menu gt gt lt i gt Basic settings 2 gt Network settings lt 3 gt ZigBee Settings 4 gt Serial sett

Download Pdf Manuals