Home
Owner`s Handbook
Contents
1. 9780 SW Freeman Drive Wilsonville OR 97070 USA Tel 800 442 2406 Fax 503 783 5334 www crimsontrace com 27 1049 09 10
2. LASER SAFETY INFORMATION Labels could not be affixed to the product but are supplied and must be installed as indicated below A Attach the Danger m warning label to the outside of the firearm g 2 5 2 Attach the Aperture warning label with the a AVOID EXPOSURE arrow pointing to the laser diode lens EMITTED FROM THIS APERTURE IMPORTANT LASER PRODUCTS MUST ONLY BE OPERATED WITH THE SAFETY LABEL APPLIED TO THE FIREARM OPERATING INSTRUCTIONS Crimson Trace laser sights are activated by one or two strategically located pressure pad s With a normal shooting grip your hand will naturally depress the activation pad whether shooting right or left handed A master ON OFF switch is also provided to turn the laser off The laser should be left in the ON position under most circumstances Leaving the master switch ON will NOT decrease battery life Please Note not all Crimson Trace laser sights have a master switch CAUTION USE CAUTION WHEN ACTIVATING THE LASER TO AVOID DIRECT EYE EXPOSURE WHICH CAN RESULT IN PERMANENT EYE DAMAGE FOLLOW ALL PRECAUTIONS AS OUTLINED BY THE FIREARMS MANUFACTURER KEEP THIS AND ALL FIREARM RELATED PRODUCTS LOCKED AND SECURED FROM CHILDREN OR OTHER UNAUTHORIZED USERS 1 800 442 2406 WWW CRIMSONTRACE COM S WINDAGE amp ELEVATION ADJUSTMENTS Crimson Trace laser sights are pre sighted at the factory to 50 feet Many tim
3. battery compartment may affect laser operation and performance Crimson Trace products use commonly available batteries gt Lasergrips use two 2 CR2032 or DL2032 batteries two 2 CR 2025 or DL2025 batteries for use in LG 438 and one 1 CR123 for use in LG 344 gt Laserguard models use a one 1 1 3N or two 2 each 357 Silver Oxide batteries To replace batteries 1 Ensure that your firearm is unloaded 2 Check again 3 Remove laser sight and old batteries 4 Install new batteries in accordance to installation guide for your particular laser sight SPECIFICATIONS BAS RON Es Class 3R Visible Laser Diode PEAK POWER 5mW WAVELENGTH 633 gt Red Diode BEAM SIZE 90 of Light Contained in Approx 0 5 Circle at 50 Feet BATTERY LIFE Four 4 Hours of Illumination Five 5 Year Shelf Life This product complies with 21 CFR 1040 10 Manufactured by Crimson Trace Corporation 1 800 442 2406 WWW CRIMSONTRACE COM WARRANTY CRIMSON TRACE CT warrants that this product will be free from defects in materials and workmanship for a period of three years from the original retail purchase CT will repair or replace with an item of equivalent value at its option any product or part which is found to be defective under normal use and service without charge during the warranty period CT s obligation to repair or replace shall be the purchaser s sole and exclusive remedy under this warranty This warra
4. sight and the bore the actual change in point of impact at these distances is very small Further adjustments can be made at the range to determine where your bullet impacts in relation to your firearms fixed sights The laser should be moved to the actual impact point of the bullet Fig 2 TROUBLESHOOTING Occasionally one of the adjustment screws will turn but not adjust the beam If this happens turn the windage and elevation screws counter clockwise until 1 2 threads of the sight screw are protruding from the housing of the diode DO NOT remove the sighting screws from the grip If sight screw is removed you will need to send in your grip for repair if necessary refer to warranty work instructions at back of manual Once 1 2 threads are visible lightly tap on the side of the diode housing with your finger to help reset the sighting spring To finish turning a 1 4 turn at a time alternate from windage and elevation to slowly sight in your laser sight to your fixed sights NOTE The Laserguard elevation screw is recessed therefore the left side of the Laserguard will need to be removed to make the threads of the sight screw visible Follow instructions above and reinstall right side of Laserguard prior to realigning your laser sight 1 800 442 2406 WWW CRIMSONTRACE COM 5 MAINTENANCE Laser sights require minimal attention and are designed to resist most common firearm chemicals and lubricants however excessive exposure t
5. Crimson trace LASER SIGHT 44 44 FEEL FREE TO CONTACT US AT 1 800 442 2406 WITH ANY QUESTIONS YOU MAY HAVE REGARDING YOUR LASER SIGHT WE ALSO ENCOURAGE YOU TO VISIT US ONLINE AT WWW CRIMSONTRACE COM HERE YOU CAN REGISTER YOUR PRODUCT FIND VALUABLE INFORMATION ON TRAINING AND TACTICS OR JOIN FELLOW CRIMSON TRACE USERS ON OUR ONLINE FORUM CONTENTS LASER SAFETY INEORMATION PEER 3 OPERATING INSTRUCTIONS oon CET LL E R E EE ES 3 WINDAGE ANDIELEVATION ADJUSTMENTS stew men ten imei 4 MAINTENANCE 6 BATTERY INSTALLATION c EL T osc toc oN oO DOG dO OOOO DE OD T 8 FOLLOW THE FOUR BASIC RULES OF FIREARM SAFETY 1 Handle all firearms as if they are loaded 2 Never let the muzzle cover anything that you are not willing to destroy 3 Keep your finger off the trigger until your sights are on the target and you are ready to fire 4 Be sure of your target and what is beyond it PLEASE READ THE ENTIRE MANUAL Failure to follow these instructions and procedures may result in injury or death gt Always follow firearm safety rules as outlined by the firearms manufacturer gt Do not point the laser beam at eyes This could result in permanent eye damage gt Keep this and all firearm related products locked and secured from children or other unauthorized users 1 800 442 2406 WWW CRIMSONTRACE COM 2
6. es no further adjustments are required All products are fully adjustable for windage and elevation if further adjustments are desired A good starting point is to align the laser with the fixed sights on the firearm Fig page 5 A two screw alignment system is used to adjust for windage and elevation The adjustment screws are located just behind the laser source use the supplied allen wrenches to make any adjustments Refer to the figure below and reference your particular model for sighting instructions For additional information on your model please refer to the installation guide included DO NOT OVERTURN THE ADJUSTMENT SCREWS A little adjustment goes a long way Rarely is more than a half a turn is required to make your needed adjustments LASERGRIPS PLATFORM LASERGUARD PLATFORM COUNTER COUNTER LEFT CLOCKWISE LEFT CLOCKWISE RIGHT CLOCKWISE RIGHT CLOCKWISE ELEVATION ELEVATION CE ED DOWN COUNTER AT DOWN CLOCKWISE CLOCKWISE UP CLOCKWISE UP COUNTER CLOCKWISE 1 800 442 2406 WWW CRIMSONTRACE COM WINDAGE amp ELEVATION ADJUSTMENTS conr Al 7 FIG 1 BEAM LINED UP WITH FIG 2 BEAM MOVED TO LINE PROPER SIGHT PICTURE UP WITH IMPACT POINT Start by lining your laser sight up with your fixed sights at a desired distance Most people sight in their laser at between 20 and 50 ft However because of the offset between the laser
7. nty does not cover normal maintenance and service and does not apply to any products or parts which have been subject to modification misuse carelessness accident improper maintenance or repair other than CT This limited warranty is in lieu of any and all other warranties expressed or implied including but not limited to merchantability and fit for particular purpose CT shall not be reliable for indirect incidental consequential or special damages arising out of or in connection with product use and performance even if it has been informed of the possibility of such damages This warranty does not cover the finish of any Pro Custom products cosmetics batteries or problems arising from faulty batteries For warranty service call Customer Service at 800 442 2406 or email customer crimsontrace com for a Return Authorization Number RMA Fill in RMA number on the form below and attach to outside of package Carefully package unit and affix mailing label as shown below Crimson Qrrace RMA 9780 SW Freeman Drive Wilsonville OR 97070 Phone 800 442 2406 VISIT US ONLINE AT WWW CRIMSONTRACE COM OR CONTACT US AT BE 1 800 442 2406 TO REGISTER YOUR PRODUCT MADE IN THE Crimson Trace holds several patents and may have other patents pending that cover its innovations Please review individual products for patent numbers to determine the specific patent coverage 1 800 442 2406 WWW CRIMSONTRACE COM 8 Crimson rrace
8. o these chemicals can be detrimental To ensure the safe and effective operation of your laser sights gt Remove Laser Sight before cleaning gun gt Do not use pressurized or compressed air gt Do not immerse in cleaning fluid or lubricate firearm excessively A firearm that has too much oil will foul the lens of the laser and result in an unfocused beam This can be easily cleaned and causes no permanent damage Do not allow cleaning solution to enter lens source Do not allow solvents to contact your grips that contain VOCs or TCE such as carb brake cleaner acetone MEK gasoline Grip damage will result v v v Crimson Trace diodes are designed and positioned to minimize exposure Occasional cleaning of the lens is recommended AFTER EXTENSIVE SHOOTING YOU MAY NOTICE A DEGRADATION OF BEAM QUALITY OR BEAM SPREAD THIS IS THE RESULT OF FOULING ON THE LENS SURFACE THIS IS NORMAL AND CAN BE EASILY CLEANED WITH THE INCLUDED CLEANING SWABS OR A SMALL COTTON SWAB DIPPED IN ISOPROPYL ALCOHOL OR WINDOW CLEANER DRY THE LENS WITH A CLEAN DRY SWAB WHEN CLEANING THE LENS DO NOT TOUCH LENS WITH ANY SHARP OBJECTS 1 800 442 2406 WWW CRIMSONTRACE COM 6 BATTERY GUIDELINES amp REPLACEMENT Our batteries provide four 4 hours of illumination under normal conditions If the laser becomes dim or fades simply replace the batteries Keep battery compartment free of dirt or other contaminants Debris inside the
Download Pdf Manuals
Related Search
Related Contents
Espacio de Colaboración de la CITEL: Proceso de Registro Guía del Morea Enterprise NVR System Viewing Workstation Kit Quick Start Guide 取扱説明書 保管用 DTC4500 - ID Wholesaler 知識マーケティングの必要性 Einbauanleitung Installation Manual VW Beetle 21th. 05/2011 Telenet Internet Guide de l`utilisateur 広域環境放射線モニタ 発注仕様書 平成26年11月 北海道原子力環境 Copyright © All rights reserved.
Failed to retrieve file