Home
USER MANUAL - Heat Mat Ltd
Contents
1. to monitor your energy consumption In the thermostat you can read out Total switch on time in percentage in the latest 2 days 30 days or 365 days Calculation of operational costs per day Switch on time 100 x kW x kWh price x 24 h per day Example Read out 30 in the latest 365 days Size of heating system 1 2 kW ask the installer Cost of power 5 p kWh Calculation 30 100 x 1 2 kW x 5 p kWh x 24h 0 4 per day 2 days 30 days Press UP A or DOWN V button to show the different 365 days xs readouts Software version No changes can be made here Use the OK V button to 1 end Regulation sensor Limit sensor if used Function selection 4 event sequence The actual sequence is blinking wanted program by clicking OK A 7 7 4 events which are common for all 7 days 7 0 4 events for each of the 7 days Selection of type As standard the thermostat controls the temperature within the room and use the externally temperature sensor as limit sensor avoiding to high or to low temperatures in the floor select roLi If you only want the thermostat to control the floor temperature select FLo In this case the room temperature is not controlled When changing to control after a floor temperature the temperature will be increased with 5 C Example if controlling after a room temperature of 20 C setting ro roLi it will control after 25 C when set for Flo roLi Room temperature control with floor limitation s
2. USER MANUAL Heated Floor Systems Programmable Thermostat 57636 11 06 BJ Introduction The thermostat is capable of switching on your heating system at pre determined times on different days of the week It is possible to set 4 periods called events each day with different temperatures From the factory a default schedule is programmed suitable for most installations Unless you change these settings the thermostat will operate to this default program Working with lower temperatures during times that the room is unoccupied could lower your energy costs without reducing the comfort The thermostat has an adaptive function that automatically changes the start time of a heating period so that the desired temperature is reached at the time that you set After 5 days the adaptive function has learned when the heating must be switched on The thermostat has a pin button marked R allowing you to reset the thermostat to factory settings These are listed at the end of this manual with space for you to record your own weekly schedule The display is backlit when operating the buttons The heating element is switched off when the light is on in the display The heating system can be switched off on the built in interrupter The Microprocessor taking care of the time will still be supplied with power whereby time and day will be maintained When the heating is required and the thermostat is switched on it will continue the 4 event programme
3. based on present time and day 1 Getting started f Display symbols Buttons BR0929G06a Pin button Reset to Adjustment Time and adjust of factory down j temperature clock setting OK Adjustment Display Heating on 4 event symbol accept up Monitoring Xt Wake Q Out of switch on iie C Night Home Setting the thermostat into operation First time power is connected the clock and day will be flashing and must be set If you need to adjust the time of the thermostat at a later date insert a pin into the hole for setting of time and day and press for 3 seconds Adjustment must be made for summer and winter time Press the UP A or DOWN V buttons to select the correct time and press OK button V Then press the UP A or DOWN V button to select the correct day and press OK V button Then press the UP A or DOWN V button to select the requested temperature in manual mode and press OK y button e To activate the 4 event clock mode press the OK V button once e The temperature set in room temp This can be changed to floor sensor only if the programmer is outside the room in a cupboard or ina warm room See 4 Advanced Optional Settings APP 2 Daily use of the thermostat 4 event clock mode The day has been split into 4 events describing a typical day When the thermostat is in 4 event mode it will automatically adjust the temperature according to the required temperature to the required t
4. emperature to rise to 25 C Press OK V button for 3 seconds and the start time is displayed Change this to 07 00 with the UP A or DOWN V button Press OK Y to confirm The temperature is now displayed Change this to 25 C with the UP A or DOWN V button Press OK v button to confirm This action can now A 14 Time and temperature be repeated for the second event f Time and temperature These settings are valid for the weekdays 1 7 Monday to Sunday which are shown on the display Depending on the program chosen the settings can be made for one single day or common settings for all 7 days Time and temperature If program 7 0 has been chosen it is possible to program the 4 event settings individually The temperature can be set within the range of 5 to for each day of the week 27 C when first switched on This can be increased up to a maximum of 45 C under tiles only See 4 Advanced Optional Settings HiLi Your thermostat is now programmed to your desired settings Should you wish to use any further options please read on 4 Advanced Optional Settings Only use if directed in previous sections Press both UP A and DOWN V buttons together for 3 seconds INFO is displayed Press UP A button until you reach the desired sub menu Select the sub menu with the OK V button Monitoring of energy consumption The thermostat calculates average time it has been switched on allowing you
5. ensor FLo Floor temperature control Max and min allowed temperature of the floor surface Max limitation is used for safety to prevent high floor temperatures For example wooden floor constructions which should not be allowed to exceed a maximum of 27 C The value can be set from 5 C up to 55 C Low limitation is used where the temperature of the floor is required never to fall below the minimum set temperature Example in kitchens or bathrooms with tiles The value can be set from 5 C up to 30 C Remember the max limit temperature must be set higher than the min limit temperature Maximum allowed temperature setting Use the UP A or DOWN VY button to increase or reduce and OK V button to accept Next is displayed LoLi Press OK V button to continue Minimum allowed temperature setting Use the UP A or DOWN VY button to increase or reduce and OK Vv button to accept 4 Continued Adaptive function This function enables the thermostat to calculate when it needs to switch ON so that the required temperature is reached at the set time With a start time of 07 00 therefore the thermostat may switch ON as early as 06 00 so that the desired temperature of 25 C is achieved by 07 00 Without this function set the thermostat will start to heat at the time you set Press the DOWN V button to switch between on and off Press OK y button to confirm Offset A correction of the control temperature can be made ass
6. ime These settings are valid for the weekdays 1 7 Monday to Sunday which are shown on the display Depending on the program chosen the settings can be made for one single day or identical settings for all 7 days ay i fi at 4 event clock mode The clock function symbol and one of the 4 event symbols O will be indicated Programming see 3 Comfort mode Temporary override To temporarily override the temperature in the 4 event schedule program press the UP 4 or DOWN V button once to show the temperature and press again to increase or decrease the temperature Press the OK Y button The override will operate until the next programmed event when the unit will resume the automatic programme Cancel comfort mode To cancel the override state press the OK Y button twice Manual mode Permanent override During holidays the scheduled 4 event program can be overridden Press the OK V button and then the UP A or DOWN V button until the override temperature is set The unit will now operate to this temperature permanently Press the OK V button Cancel manual mode To cancel the permanent override state press the OK Y button once and the unit will resume automatic function 3 Programming 4 event time and temperature For each event the start time and required temperature must be set For example in the morning you wish the heating to start ager Vine aaa teeta at 07 00 and the t
7. uring influences from the installation are eliminated The correction can be set from 5 C to 5 C Press OK v button to end programming and to return to scheduled programme 5 Reset to factory setting Press the pin button in 3 seconds and the thermostat returns to factory settings Time and day is also reset and must be set according to Setting the thermostat into operation Factory settings 4 event time and temperature 6 Failure codes EO _ Internal failure replace thermostat El Built in sensor short circuit or disconnected replace thermostat E2 External sensor short circuit or disconnected Heat Mat Limited 8 Ashwyn Business Centre Marchants Way Burgess Hill West Sussex RH15 8QY Tel 01444 247020 Fax 01444 247121 gt 6 S