1. Installation Installation notes Vent hole on back of keypad should not be blocked The back of the in k800 should not be enclosed where water can gather but instead cut out in k800 must be installed on the outside edge of the hot tub so that it is not subjectto moisture trapped by the cover Connecting in k800 keypad to the spa pack Main keypad in k800 To connect the in k800 keypad simply insert its in link connector into the appropriate keypad connector of the pack enclosure as illustrated b Installation Installation errors Upon connecting the in k800 to the spa pack you may see one of two error messages Z WARNING B X A The spa pack does not have There s a problem valid software Please communicating with the insert valid in stick to zi pack Please check keypad reprogram spa pack connections or update pack software Please follow the instructions
2. iIn kKBOO intuitive color keypad Full color control On screen audio control Water care selection Spa d mur 0 90 55 Wabercare Beginner nk Filtering is active GECKO Table of contents am na 2 h tO UCL RZ L s ERR 3 Overview TPKE OO ditnehsionhse edat isi e EEG po Donee ee itat 4 Installation zInstallaloLtob lids OD as l Bul 5 s lonlih inpiiii m 6 Stata b b basi 7 Connecting in k800 keypad to the spa pack sess 7 Instalan SONGS viens ier cati A 8 Connecting the in stream and in tune to the spa pack E T UPS 9 EMO o Pc A 9 Keypad functions sin KO OO Keypad on 10 o nett 10 2 ModE o o foo 10 2259057 0 0 10 SA 10 lt OtalLorstop 4e6e9S0H eee AEE Tl SESIONES 1 Mater tempetatule a ds 12 x oo Ar EE 12 NGT C D HP nes 13 Walter CALE modes ad ide ttd aa 13 Mode schedules dope tee itc 14 s Ad RU 14 in clear 200 linked version 15 MADENGE t E 15 s AMalhitenatace Temillidelse aura ve tens io ia 16 Z L B D BUS 16 A aba a tO an plan n 17 Date ande al aaa 18 O stc m AS 18 boul O ON 19 Electrical cont Ur dd 20 lt thactory reset Audio configuration sei s lb dee e
3. Changing tracks Use the Last Track and Next Track keys to change tracks forthe CD or AUX input When in Radio mode the Last Track and Next Track keys will move through preset radio stations on the selected band To change bands or preset stations see your in tune manual 23 24 Keypad functions in stream functions This menu is available only if the in stream was selected in the audio configuration menu AUX Power Volume Up Down Bluetooth a Mode m Last track Next track 7 Play Pause Press the Mode key to access your in stream Play Pause audio If you are using a device with Bluetooth technology Press the Play Pause button to start or pause the audio it must be connected for functions to work Adjusting the volume Please note that the Play Pause and Change Press the Volume Up orthe Volume Down key Track functions apply to devices using Bluetooth to technology only and will not work when AUX is selected as the source Changing tracks Use the Last Track and Next Track keys to change tracks Turning power On Off Press the Power keyto turn the in stream on of off Disconnect or Unpair Bluetooth Selecting the source These options can be found underthe Audio section in the Settings menu Press the Bluetooth key to selecta device using 5 Bluetooth wireless technology Press the Source key to use a device connected to the auxiliary cable If n
4. Only available with the latest software version of the X and Y Series spa systems ar b Specifications Part number 0607 008025 Model IN K806 CL GEl Environmental Operating temperature 4 F 20 C to 149 F 65 C Storage temperature 22 F 30 C to 185 F 85 C Water ingress protection IPX 5 Mechanical Weight 1 05 Ibs 0 48 kg Dimensions W x Hx D 8 730 x 4 231 x 2 029 221 74 mm x 10747 mm x 51 57 mm Audio specifications Audio source supported in tune and in stream Compatibility in yt in ye in yj in xe or in xm2 spa packs with appropriate software revision Specifications are subject to change without prior notice 9919 101191 E Rev 04 2015 O Groupe Gecko Alliance Inc 2015 All trademarks or registered trademarks are the property of their respective owners GECKO Gecko Alliance 450 des Canetons Quebec City Qc G2E 5W6 Canada 1 800 78 GECKO www geckoalliance com Printed in Canada
5. BUT IS NOT LIMITED TO FIRE FLOODING OR OTHER WATER DAMAGE DIELECTRIC BREAKDOWNS PRESENCE OF HIGH VOLTAGE ETC MAINTENANCE If you have problems do not attempt to repair the unit yourself Return it to your dealer or service station for servicing ACCESSORY PARTS Be sure to use only the specified accessory parts Use of other than designated parts may damage this unit internally or may not securely install the unit in place This may cause parts to become loose resulting in hazards or product failure DISPOSAL OF THE PRODUCT The appliance orthe product must be disposed of separately in accordance with the local waste disposal legislation in force Compatible spa controllers in xm2 in xe in yt in yj and in ye with compatible software revision Aeware Gecko and their respective logos are Registered Trademarks of Gecko Alliance Group in k800 in xm2 in xe in yt in ye in yj in tune in stream in mix in clear in touch and in therm and their respective logos are trademarks of Gecko Alliance Group All other product or company names that may be mentioned in this publication are tradenames trademarks or registered trademarks of their respective owners Introduction in k800 intuitive color keypad With its bright full color display the in k800 provides an intuitive user experience while its screen s high resolution brings hot tub user interfaces to a new level Loa
6. Modifying schedules To modify a VVater Care category use the lit key to the right key 5 to open the selected VVater Care menu You can add schedules by scrolling down to Ada and selecting with key 2 To delete a schedule press key 4 You can modify the programmed schedules by selecting one and adjusting the schedule using the arrow keys Use key 2 to move between parameters You have several possibilities for the schedule Mon Fri weekend every day or single days The schedules will be repeated every week The time and duration are set in 30 minute increments Once you have set the schedule use key 1 to go back Ensure that you have selected the desired Water Care option in the main Water Care menu Audio The in k800 can be used with either the in tune or in stream audio system The Audio section in the Settings menu gives you the option to disconnect or unpair your Bluetooth enabled device when using the in stream For more information on audio functions see the in tune or in stream operation section Keypad functions in clear 200 linked version The in k800 keypad can be used with the in clear sanitization system The in clearsection allows you to configure your maintenance settings and Boost level For more information on maintenance and Boost settings see the in clear user manual Use the Up and Down keys to make your selection then key 2 to confirm Use the Up and Down keys to change th
7. good level of BromiCharge start the pumps and add the specified amount of BromiCharge and allow 5 minutes for the indicator to adjust before adding more For optimal performance aim for the middle of the green zone For more information on adjusting your BromiCharge level see the in clear user manual 25 b Error messages The list belovv shovvs the different error messages that can appear on the home screen Refer to the troubleshooting and error codes section of the TechBook for your spa pack system Please note that if you are in svvim spa configuration the message may be follovved by a Master or Slave to designate from vvhich pack the error is coming CODE MESSAGE HL High Limit circuit has trippedl FLO No Flovv condition for more than 2 hours FLO No Flovv condition HR A hardvvare error vvas detected Relay stuck OH Spa temperature is too high Er Temp probes or detection circuit are defective AOH Elevated internal temperature FLC The pressure svvitch is closed SP in Input voltage issue RH NC Comm error between in xm2 in therm RH ID in xm2 and in therm incompatible SC ER Error detected during the learning mode Fl in xm2 Fuse 1is blown F2 in xm2 Fuse 2 is blown F3 in xm2 Fuse 3 is blown ERI SwimSpa config slave unit is missing Hr Hardware error was detected Thermal fuse UPL The spa pack does not have valid software Please insert valid in stick to reprogram spa pack CFLO No Flow co
8. oU 21 A O O 21 s LX TUITE ONS eto eo 0 22 SITUS NUN CULO uz sb b 23 b O oai aa ete 24 s CICA I MUG oh 25 EEEOPT S 26 27 b VVarnings N WARNINGS Before installing or connecting the unit please read the following FAILURE TO COMPLY WITH THE FOLLOWING WARNINGS MAY SIGNIFICANTLY SHORTEN THE PRODUCT S LIFE TIME AND LEAD TO FAILURES AS WELL AS HAZARDOUS COND T ONS COMMON SENSE MUST ALWAYS PREVAIL WHEN EVALUATING THE INSTALLATION AND OR USE OF ANY ELECTRONIC CONTROL IN A FINAL APPLICATION e RESPECT ENVIRONMENTAL CONDITIONS LISTED AT END OF TECHBOOK e THIS UNIT MUST BE INSTALLED BY QUALIFIED PERSONNEL e ONLY QUALIFIED PERSONNEL ARE TO SERVICE THIS UNIT THERE ARE NO USER SERVICEABLE PARTS INSIDE e THIS UNIT SHOULD BE INSTALLED ON A CLEAN FLAT SURFACE e THE GASKET ON THE BACK OF THE UNIT WILL PREVENT WATER INFILTRATION INSIDE BEHIND THE MOUNTED SURFACE IF THE GASKET IS DAMAGED SEAL THE BACK OF THE UNIT WITH SILICONE TO AVOID ANY LEAKAGE BEHIND THE MOUNTED SURFACE e THIS UNIT MUST BE MOUNTED ON THE OUTSIDE EDGE OF THE SPA SEE INSTALLATION SECTION FOR DETAILS e THE BACK OF THIS UNIT SHOULD NOT BE ENCLOSED IN A WAY THAT CAUSES WATER TO COLLECT SEE INSTALLATION SECTION FOR DETAILS HAZARDOUS CONDITION A CONDITION THAT IS POTENTIALLY DAMAGING AND OR DANGEROUS TO THE OPERATOR OR SURROUNDINGS THIS INCLUDES
9. ation for your spa Low level configuration 1 pump 2 pumps 2 pumps blower 3 pumps 3 pumps blower 4 pumps 4 pumps blower 5 pumps 5 pumps blower Note that with a special low level configuration it is possible that the blower has been set to always remain on key 5 Key 1 Pump 1 Pump 1 Pump 1 Pump 1 Pump 1 Pump 1 Pump 1 Pump 1 Pump 1 Key 2 Pump 2 Pump 2 Pump 2 Pump 2 Pump 2 Pump 2 Pump 2 Pump 2 Key 3 Key 4 Key 5 Key 6 Light Light Blower Light Pump 3 Light Pump 3 Blovver Light Pump 3 Pump 4 Light Pump 3 Pump 4 Blovver Light Pump 3 Pump 4 Pump 5 Light Pump 3 Pump 4 Pump 5 blower Light Keypad functions Factory reset Audio configuration When you select Factory Reset you will be asked to confirm your choice Doing so will reset all settings m Audio Config to factory default Following a reset you will be asked to choose your audio Y in stream source Use the arrow key to choose between in stream BN in tune and no other audio This should only be done at installation or when replacing a part About This section shows information about the in k600 software number and the revision numbers ofthe different components of your system eypad S W number Keypad S W revision 12 00 REC ee E ackK 21 27 Keypad functions in mix functions This menu will only appear if an in mix system is pre
10. ded with a large amount of memory and a powerful on board processor we have created the seamless graphic interface that spa users have been waiting for This techbook presents the different functions and menus available on your in k800 Availability of certain functions depends on the software version of your in k800 To find out which features are available for your software version referto the table of available options in the Specifications section To see which software version is installed on your in k800 refer to the About section b Overview in k800 dimensions 4 23 10747 mm 5 10 TOS 8 73 n 221 74 mm 2 03 51 57 mm Installation Installation of in k800 Gasket with or without adhesive Optional wing nuts and spacers To install the in k800 use the drilling template provided in this section Determine the mounting location and stick the template on chosen location Cut out an opening according to the template Clean the installation surface and peel the adhesive gasket from the back of the keypad Insert keypad and align it correctly then ensure it is properly glued by gently pressing evenly on the entire surface b Installation Drilling template 35 00 90 mm 0 00 203 20 mm R 0 625 15 07 mm p 0 125 3 17 mm 7 5 190 50 mm
11. e and restart the spa Keypad functions Es Hu FLO Jul 21 2014 1 30pm Problem detected Hj ERROR No Flow condition WARNING qp Erase all the error log Are you surer Confirm Error log In this section you can see errors that have been archived by the system Use the Up and Down keys to move through the list Errors are archived chronologically from most recent to oldest top to bottom The Error log page shows the error code the date of the error and the time To see more details on an error select it with key 2 A screen will appear with more information on the selected error For more information see the Error messages section To clear the Error log page press on key 4 and confirm when prompted The page will be cleared 17 18 b Keypad functions Keypad Settings Date and time Here you can adjust the time format change the year date and time Use the arrows to choose the setting that you want to adjust and select it by pressing key 2 Use the arrow keys to change the parameters and key 2 to move between parameters Key 1 will take you back to the main Settings menu Keypad settings In this section you can change the temperature unit language display orientation and rim light color Note the spa pack must be configured accordingly to be able to change the rim light color Use the arrow keys to choose the setting that
12. e maintenance or Boost value and key 2 to confirm If the maintenance value is modified by more than 2 a warning message will appear with an option to cancel or confirm the change Maintenance From the Settings page you can access the Maintenance menu which gives you access to the following options e Maintenance reminders Standby Error log Use the Up and Dovvn keys to make a selection and key 2 to confirm 15 b Keypad functions Reminders Rinse filter vvith Overdue by 31 days Bh c us E Clean filter in solution Required in 23 days ater my 16 Maintenance reminders The in k800 keypad will remind you of maintenance required on your spa like rinsing or cleaning the filter Each task has its own duration based on normal use The Maintenance reminders menu allows you to verify the time left before maintenance is required as well as to reset the time once a task is completed Use the Up and Down keys to move through the list To reset a task select it by pressing key 2 then confirm when prompted Once you have confirmed the task will be reset Standby The Standby mode allows you to service your spa Pumps will stop for 30 minutes and automatically restart after this time Once Standby mode has been activated a screen will appear to show that pumps are stopped The normal spa page will return at the end of maintenance Press on the Confirm key to leave Standby mod
13. hown at the bottom of the screen gives the actual water temperature Use the Up and Down keys to set the desired temperature The set point will appear in blue After 3 seconds without any change to the set temperature value the current water temperature will reappear When the set value is lower than the current temperature Cooling to xx x will appear below When the set value is higherthan the current temperature Heating to xx x will be indicated under the value Normally there is a short delay before the heating starts during which Heating Suspended is indicated under the value Settings From the home page you can access the Settings where you will find e Water care e Audio jn clear 200 linked version e Maintenance e Date and time Keypad Settings only available on in touch with software 11 00 or higher e Electrical configuration Factory reset e About Use the arrow keys to move up and down in the list To select an option press the lit button beside it key 2 At any point you can press the Settings button to return to the home screen or key 1 to go back Keypad functions Water Care e Away from home da Beginner 27 Energy saving GECKO Water care The Water Care section will help you set up your ideal filtration and heating settings Choose from Away from Home Beginner Energy Savings Super Energy Savings and Weekender depending on your need Use ke
14. in the message or contact your dealer for more information Connecting the in stream and in tune to the spa pack See Factory reset Audio configuration section for details on setting up audio in stream Use the adapter cable Part 9920 400976 to connect the in stream to the CO port of the spa pack in tune Use the adapter cable Part 9920 400976 to connect the in tune to the CO port of the spa pack 10 Keypad functions in k800 keypad layout Key 4 Key 1 Settings Key 2 Mode up Key 5 Down Key 3 Selection lights Light Key 6 Functions for keys 1 to 5 will depend on your system s low level configuration Settings key One press gives you access to a menu to manage the settings of your spa Refer to the settings section for details about the settings menu Mode key Successive presses on the Mode key will give access to control different optional accessories of your spa such as Audio and others Note that if an accessory is not present in your spa configuration its menu will not appear Refer to the following section to get details about the possible accessories and their detailed functionalities The screen will revert back to the spa mode if no key is pressed for 60 seconds Power Press any button to turn the keypad on After 30 minutes without activity it will shut off Main screen The main screen gives you access to your acce
15. lly Once the in touch module is connected to a Wi Fi network a green check mark will appear in the Wi Fi menu and the network name will appear in the Settings menu 19 20 b Keypad functions Hectrical configuration Please do not make changes in this section unless you are a qualified electrician In this section you can change the lovv level configuration as vvell as modify the number of phases and the entry current Use the Up Down Keys to move to the selection you vvant to modify Use Key 2 to select and the Up Dovvn Keys to move through the selections Press Key 2 again to confirm Please see the techbook for your spa system for details on low level settings Once you have changed the number of phases in the menu you will be unable to use the Up Down keys to return to the Low level configuration menu Please go back and access the menu again Please note that if there are two spa packs in the system i e a Swim Spa installation the master unit s chosen configuration must support a slave unit If after re booting the chosen configuration does not support SwimSpa installations the in k800 will return after about 45 seconds to this configuration menu and prompt the user to select a configuration number again The table below shows the key assignation based on the accessories selected in your pack s low level configuration Please refer to the pack manual for specifications to identify the low level configur
16. ndition HIBr Add fresh waterto the spa HiBr Add fresh waterto the spa LoBr Add BromiCharge to spa water NoBr Add BromiCharge to spa water Comm Verify cable connections Supp Connect power cord to 240 V source Specifications The following table presents the different options menus available on your in k800 depending on the software revision and your spa hardware Table of available options Keypad functions Keypad software Keypad software Keypad software revision 5 00 or lovver revision 6 00 to 11 0 revision 12 00 or higher Power Main screen e e Notifications Start or stop accessories Water temperature Settings Water care e Water care modes e Modifying schedules Audio in clear 200 linked version Que e Maintenance 6 s Maintenance reminders Standby Error log e e Date and time Keypad settings 0 Temperature unit e 2 Language English e e Francais Espa ol Polski e Nederlands E Deutsch e Norsk Svenska e e Display Color Wi Fi o e Electrical configuration Factory reset Audio configuration e e e in mix functions 2 in tune functions in stream functions in clear functions e About e e Only available with the latest software version of the X and Y Series spa systems and software version 11 00 or higher of the in touch module
17. o source is selected the in stream system will use the last selected source Keypad functions in clear functions This menu is only available if an in clear linked is detected Diagnostic Mode Press on the Mode key to access your in clear module This menu allows you to activate or deactivate your in clear to start or stop a Boost and to enter diagnostic mode Turning the in clear on off Press the power key to turn the in clear on or off Control the Boost level Press on the Boost activation deactivation key to start a Boost and again to cancel To adjustthe Boost level use the arrow keys A message indicating that Boost mode is active is displayed at the bottom of the main screen for the duration of the Boost See the in clear user manual for more details about Boost levels Power r Boost adjustment L Boost activation deactivation Diagnostic Mode Press on the Diagnostic key to start a BromiCharge concentration level test To exit diagnostic mode press on the Diagnostic key again The system will automatically exit after 15 minutes In diagnostic mode the BromiCharge gauge indicates the approximate level of BromiCharge in the spa water Do not add BromiCharge if the indicator is in the green zone in clear p When BromiCharge is added the indicator will move slowly to the right When water is added to the spa the indicator will move to the left To obtain a
18. sent Zone l Zone 3 Press on the Mode key to access your in mix This menu is only present if an in mix system is detected By default the in mix selects Zone 1 when you access the menu After the first use the menu will automatically return to the last zone selected Zone selection The zone selection keys allow you to select a zone to modify its color e Press once to select the zone e Press a second time to deactivate the zone Up and Down Synchronisation L Changing colors Once a zone is selected use the arrovv keys to change the colors by moving up and down in the color wheel Synchronizing zones The synchronization desynchronization key allows you to match the color of the selected zone to the other zones Keypad functions in tune functions This menu is available only if the in tune was selected in the audio configuration menu Source Mode Last track Press the Mode key to access your in tune Turning power on off Press the Power key to turn the in tune on or off Selecting the source Press the Source key to choose between CD Auxiliary input and Radio If no source is selected the in tune will use the last selected source Power 4 Next track l Play Pause Play Pause audio Press the Play Pause key to start or pause the audio Adjusting the volume Press the Volume Up or the Volume Down key to increase or decrease the volume
19. ssories and water temperature At the bottom of the screen you will see any error or maintenance messages that are present Keypad functions Start or stop accessories To start or stop an accessory press the associated button Icons will become animated when their accessory is turned on and inanimate when turned off Icons on the screen will reflect the speed or state ofthe devices running on your spa When an accessory has more than two states press the button until it reaches the desired state Notifications A notification area atthe top right hand side of the screen shows the state of certain accessories installed in the spa Notification icons in mix e Indicates that an in mix system is detected For more information about the in mix system refer to the in mix functions section in clear The icon is green when the in clear is generating bromine e The icon is grey when the in clear isn t generating bromine e A red cross indicates that the in clear is turned off For more information aboutthe in clear refer to the in clear functions section in touch e ndicates that the in touch module is detected and connected to a Wi Fi network e A red cross indicates that the in touch module is detected but isn t connected to a Wi Fi network For more information about the in touch refer to the Wi Fi section T 12 b Keypad functions VVater temperature The temperature s
20. y 2 to choose your setting A green checkmark will appear on the selected icon to confirm In Economy mode the set point will be reduced by 20 F which means that the heating system will not be engaged unless the temperature falls to 20 F below the spa s set temperature The filtration schedule shown on the screen will apply to the main filtration pump most likely pump 1 If your spa uses a circulation pump configured to run 24 hours the screen will show you the purge setting instead of filtration The purges are pre programmed for a fixed number of minutes therefore the duration will be set to N A on the screen and only the start time can be modified Default pack value Water care modes Away In this mode the spa will always be in economy the set point will be reduced by 20 F Beginner The spa will never be in economy mode and will be filtering according to the pack s low level configuration Energy Savings The spa will be in economy mode during the peak hours of the day and resume normal mode on the weekend Super Energy Savings The spa will always be in economy mode during peak hours every day of the week Weekender The spa will be in economy mode from Monday to Friday and will run normally on the weekend Filtration will be reduced when the economy mode is active 13 b Keypad functions pa x y SS Weekend 12 00am 12 00an E Add NM SL IU 14
21. you want to adjust Select it by pressing key 2 then use the arrow keys again to change the setting When you change the display orientation the contextual options and arrow keys adjustto the chosen orientation The Mode and Menu keys remain unchanged as well as the accessory keys in the main Spa menu Keypad functions Settings 3 Keypad Settings gP Electrical Config 4 Factory Reset Wi Fi Forthe Wi Fi menu to appear in the Settings menu your in touch module must be equipped with software version 11 00 or higher This menu allows you to connect your in touch module to a Wi Fi network orto change its network For more details about other in touch connection methods please see the in touch techbook To connect your in touch module to a wireless network use the Up Down keys to go to the Wi Fi option in the Settings menu and key 2 to select it After a few seconds the available networks will appear on the screen as well as their signal strength Use the Up Down keys to move through the list Select your network by pressing on key 2 If the Wi Fi network is password protected enter it when prompted Use the arrow keys to choose your letters Use key 6 to move the curser forward Use key 4 to change the type of character uppercase lovvercase number symbol Use key 3 to backspace e Use key 2 to confirm If no password is required the in touch will connect automatica