Home

to the User Manual

image

Contents

1. Good Husband Remote Lighting Lifter National Patent Number 0520069085 5 200520075680 X 200520075677 8 200520075679 7 International Patent Number T 2006 000409 Product Standard 0 QABC002 2005 Model CUIILELILS OBrief Introduction of Product 02 OStatement of Product s Quality 03 OPoints to Attention 05 DDJ 50 oSpecification and Technique Parameter 07 oBasic Components 09 DDJ 150 DDJ 250 OQptional Accessories 10 o nstruction for Installation 11 OInstruction for Operation 2 Dear Sir Madam Very thank you for selecting Good Husband Lighting Lifter We will provide you a modern comfort and safety environment Hope to receive your valuable opinion for our product and services A To ensure safe operation please read the manual carefully before using the lifter Please keep the instruction manual properly for further reference A Please entrust a professional technician to install the products to ensure safety Remote Lighting Lifter is a general lighting equipment which is not allow to use at the inflammable environment Note Please be tolerant that we will reserve the rights to make changes without notice Brief Introduction of Remote Lighting Lifter Remote lighting lifter is a general illumination equipm
2. 8 x 353 90 DDJ100 M6X60 a DDJiS0 MIOXI00 diOx390x90 _ Mins0 4 1 2 Tighten the nuts firmly to ensure the force balance of each bolt Please refer to Nut Tightening Force Moment Table 11 15 Instruction for Installation Nut Tightening Force Moment Table II Note The performance level of the Hexagon NO eae nut gt Grade 5 The performance level of the Hexagon Head Set Nut Screw M6 5 5N m screw gt Grade 6 8 Galvanized surface The surface should not be coated with Hexagon Head Set Nut Screw M8 15 5N m grease before tightening and the tightening force moment should not be lower than Hexagon Head Set Nut Screw MIO 26 4N m the reference data on this table 2 0 Roof beam installation refer to diagram 2 2 1 There is a connector in the middle of the lifter which is for steel pipe connection The wall thickness of steel pipe should be more than 3mm The across hole on the steel tube is drilled based on the bolt diameter 2 2 The connection of steel pipe and steel beam should be completed by qualified technicians to ensure the connection is reliable 3 0 Connection with 4 long screws refer to diagram 3 3 1 Make a square board according to the technique requirement of the attached diagram The connection of the square board and steel beam should be completed by qualified technicians to ensure the connection is reliable 16 Instruction for Installatio
3. little bit again Please release the two buttons when the steel wire rope goes down again At this moment the memory lower limit position of control unit has been set up successfully If there is other 22 Instruction for Operation operation applied suddenly during the steel wire rope going down the lower limit position of the wire will not be controlled by the main unit memory At this time the lower limit position should be controlled by people However the memory lower limit position of control unit will remain same and auto stop function is still effective when the lifter goes down next time 3 Reset memory function for lower limit position of remote control e Cancel the setup Please keep press DOWN button for around 8 10 seconds and release it when the lifter has reached its lower limit position After that press UP button on the remote control the lifter will reached its upper limit position and stop automatically At this time the memory setup has been cancelled Renew the setup The memory datum of the lifter will be renew if you reset it according to the instruction 2 4 Function for reset signal code Keep press up and down buttons for around 8 10 seconds and release it after the lifter is electrified within 5 seconds The lifter will go down if you press DOWN button on the remote controller At this time the instruction for signal code has been reset successfully You have to reset the m
4. ding and power leakage The stamped screws should be tightened and rechecked one by one to ensure the connection is fixed well when in the process of connection Warning Attention to Maintenance between Lifter and Lamp 1 After the lamp lifter stop later the lifter still contains electric please turn off the switch which control this lamp only then you may carry on in the maintenance work 2 There are not allow having the wet water greasy dirt coherences metal and so on appear at the electric conduction contact face while in maintenance 3 You should keep the tension with 5kg of the steel wire while in maintenance When the steel wire rope descend too long it will twist or loop itself and be able to affect of using the steel wire rope 20 Instruction for Operation Operation Instruction of Remote Controller md UP Key Press UP for one second when DOWN Key the lifter is in the state of stop The Press DOWN for one second lifter begins going up when the lifter is in the state of stop Press any key for one second The lifter begins going down when the lifter is going up The Press any key for one second lifter stops operating Remote Controller When the lifter 1s going down The lifter stops operating Battery Change of Remote Controller If the indicator becomes dim or is off when the power on change a new battery If the remote controller
5. emory function for remote control lower limit position otherwise it is ineffective Instruction for Operation Warnings After the lifter set up the height of lower limit position the lower limit position of the lifter will not be controlled by the main unit memory if the artificial operation halts the lifter suddenly while it is going down At this time the lifter should be controlled by people and you have to pay attention to the safety People cut off the electricity suddenly while the lifter is operating and it will cause the signal code lost and malfunction People cut down the heavy until the machine stop suddenly while the lifter is operating and it will cause the lifter malfunction The installers have to read the instruction manual carefully before install the remote lighting lifter Please contact us for further information if any problem or query Email lightingliftter gmail com Tel 0086 592 8067637 24 Three Commitments We perform three commitments repair replace and refund According to the relevant stipulation in Protection Law for Consumer s Rights and Interest our company will provide you the service based on your warranty card and purchase invoice 1 This product is fully warranted against defective materials and manufacturing fault for a period of 12 months from the date of purchase 2 Examples of the foregoing but without limitation are a Products damaged during installation or incor
6. ent which is easy to install safety and convenient when in use and etc Besides that it is also allowing you easy to clean and maintain the lamps which were hanging at the higher place It can be recognized as a modern decoration design and practical equipment which is worth to popularize The lifter is composed of Mechanism Driving Parts and Electronic Control Circuits ECC The electronic control circuit contains a remote control unit The manual function of the wireless remote control is ascend amp descend stop pause However the auto function of the wireless remote control is able to stop when the lifter is in the lower limit position amp upper limit position or when the lifter is carrying weight over maximal loading capacity or weightless The lifter has mechanical safe mechanisms to secure the chandelier when not in operation or during power failure and can be programmed to automatically stop at the optimum lowered position You no need to destroy your beautiful decoration or modify any original circuit even though you would like to install the lifter against the lamp that has been installed on the ceiling Remote Lighting Lifter is general lighting equipment which is not allowed to use at the inflammable environment Statement of Product s Quality The trademark of Good Husband and the DDJ series of remote lighting lifter which 18 manufactured by our company is accord with the safety for electronic product of China laws a
7. er Diagram4 2 The center place of the lower part of the lifter is equipped with a bar There are 2 screws and nuts on the bar which for center distance adjustment This connection method is suitable for the lamp with the weight of less than 50kg Diagram 5 Bolt Cushion Slide Connection Bar Cushion Ring Diagram 4 Diagram 5 13 Instruction for Installation 3 There is a faceplate at the lower part of the lifter which is provides multi holes for the bolt connection This is suitable for the bigger ceiling mounted This connection method is suitable for the lamp with the weight of less than 100kg The attachment is optional accessories Diagram 6 Bolt Faceplate for Connection Cushion Nute Diagram 6 14 Instruction for Installation The requirements and caution of the connection of upper part of the lifter 1 0 Tightened with expansion bolt s Please refer to Diagram 1 1 1 All drilled holes should be handled strictly according to the technique requirements on the Drilled Hole Specification for Concrete slab 1 The spare holes are located on the square board of the lifter for special condition use if there is reinforced when you are drilling the holes Drilled Hole Specification for Concrete Slab Table 1 Diameter of Specification of Depth of Drilled Hole and Quantity of Expansion Bolt Drilled Hole Distance of Hole Bolts mm mm mm DDJ50 M6X60
8. g the ring to avoid people is hurt You have to stretch the steel wire rope first before you carry on the connection testing Instruction for Installation IV The requirements and caution for the connection of the lower part of the lifter and the lamp 1 The attached U shape ring may be connected firmly to the lamp by the installer Please refer to diagram 4 The specifications for the bolts must be accord with the following M10 bolt is used for the lamp with the weight of less than 150kg M12 bolt is used for the lamp with the weight of less than 150 250kg bolts have to accord with the criterion of Hexagon Head Set Nut Screw with Grade C GB T5780 1986 2 Place the attached bar into the center screw position for the lower part of lifter by the installer then tighten the bolts and nuts Move the nut which is slide on the bar to the proper bolt hole of the lamp Tighten the screw according to the requirements of Nut Tightening Force Moment Table II Please refer to diagram 5 3 Assemble the attached faceplate into the center hole position for the lower part of lifter by the installer then tighten the bolts and nuts Make sure the bolt holes and faceplate slots are properly in place Tighten the nuts according to the requirements of Nut Tightening Force Moment Table II Please refer to diagram 6 4 The decoration cover should be installed after the upper part of the lifter is complete and qualified before the lower part of t
9. he lifter is installed Instruction for Installation V The connection of power supply and caution 1 Connect the live neutral and earth wire of the input supply to the corresponding points with the voltage of Ac220 240V Please refer to the diagram 7 2 You have to connect the power supply and lower conductor of the lifter according to wiring diagram 8 Please connect the live wire LA if the power of the lamp is lower There lot of live wires when the power of the lamp 15 higher Please divide the wires into two groups and connect them into L1 and L2 separately Nu oed Lower Conductor Live Wire Red Live Wire Blue Ground Wire nd o a ROO lt Black N Connected with Naught Wire Junction Box 1 2 N 3 IG KI QED Qa XS Ke RO amp SA SSS IG T 24 Blue L2 Connected with Live Wire KS gt lt I Connected with the Cable of the Lamp Wiring Diagram for Power Supply Input Wiring Diagram for Power Supply Output Diagram 7 Diagram 8 19 Instruction for Installation 3 Please make sure the exposed wires which are corresponding to the terminal are properly in place while you connect the wires so as to prevent them from contacting the metal conductor surroun
10. is ineffective or is not sensitive please change the battery The battery size is 23A12V Instruction for Operation 1 Operation Instruction of Remote Controller UP Press UP button on the remote control to raise the steel wire rope The operation is ineffective if you press any key to stop within 2 seconds At this time the lifter will not operate Test for the upper limit position The switch of the upper limit position will switch off and the lifter will stop automatically when the steel wire rope going up until the upper limit position At this time the operation is ineffective if you press UP button again e DOWN Press DOWN button on the remote control to descend the steel wire rope Press any key to stop it If the steel wire rope going down to the lower limit position which you setting before and stop automatically At this moment the operation is ineffective if you press DOWN button again 2 Memory function setup for lower limit position of remote control Instruction 2 Setup the lower limit position of remote control Press DOWN button on the remote control to descend the steel wire rope for around 5 seconds when you turn on the lifter When the steel wire rope goes down to the required herght please keep press DOWN button until the lifter stop automatically After that please use another hand to press UP button on the remote control when the steel wire rope goes up a
11. n 3 2 The lengths of the screws are subject to the size of decoration spaces Assemble with 4 long screws to adjust the upper cover board of the lifter in proper level position then tighten the nuts Please refer to diagram 3 4 0 Connection reliability test must be applied when completing the upper part installation of the lifter The test weight should be 1 5times of the rated load Lift up the heavy with the acceptable weight first when testing The lifter will not operate when it is overweight Please press the key when there 15 height of 20mm away from the ground Then add another half as much as the weight and hang it for 5 minutes The upper part of the lifter is qualified if it is hung well You have to recheck the installation process if it is not hung well when testing untilit 1s qualified AImportant Warning The operators have to wear the safety helmet during operation When the lifter is in use people should keep the distance of at least 2 meters to stand or pass underneath a load You have to use the steel tube which the length is 2m to carry the heavy by 2 persons when you would like the lifter become heavier This is to prevent from dropping off due to the unqualified concrete slab strength AImportance The lifter must have more than 5kg weight on the steel wire rope on the installation before start only then it may descend When the lifter is fully earthed you have to pay attention to the steel wire rope after releasin
12. nd regulations of environmental protection and conform to the common laws and regulations of Europe MD 98 37 EC LVD 2006 95 EC The process of product s manufacture and management of quality control is adopting by ISO9000 2000 All products have been passed by the strict safety testing and accord with the product s standard to ensure safety operation Remote Lighting Lifter Q QABC002 2005 Please read the instruction manual carefully before install and using the lifter just to assure product safety operation According to our country rules of product s quality are the law responsibilities that have to bear by manufacturer seller and the person in charge when they violate the rules of product s quality If the damages of property or personal injury due to the defect of product so our company will bear the responsibilities with compensation according to the cost of product All products of our company have been passed to quality control If the damages occurred due to agent s fault management which are improper transportation dismantle or operation reasons so the agents have to bear the responsibilities Statement of Product s Quality products of our company have been passed to quality control If the damages of property or personal injury due to the improper installation and checking so the installer have to bear the responsibilities himself products of our company have been passed to quality control If the damages of proper
13. nspection Points to Attention CAUTION OF OPERATION Warning 1 The lifter only can be operated when it is carrying heavy 2 Don t clean the steel wire rope with water or corrosive cleaner the steel wire rope can be damaged 3 Examine the steel wire rope regularly while in the process of cleaning lamps for any rusty corrosive or damaged 4 Please apply a coat of anti rust grease on the steel wire rope after cleaning the lamps 5 Please entrust a professional technician for its maintenance Specification and Technique Parameter Specification Overall Size Standard Lifting Lengthened Rated Load kg LOO P Lifting Height Max m yy 0x 33020 4 13 Dozo 201300 10 17 10 DDJ 250 250 450x450x110 25 __6 12 Specification and Technique Parameter Technique Parameter er ae a oe fot Swi _ Power Consumption of Lifter W Illumination Power Consumption kw s m Illumination Rated Current A Basic Components qu amp ampp Lighting Lifter s Remote Controller Expansion Bolt AO 2 E Connection Cable for the Lamp Diagram for Basic Components Optional Accessories Diagram for Optional Accessories Note The optional accessories should be conformed to the specifications of connection structure
14. of ceiling lamp m SR 0 IF NS NY Connection Part s for the Lamp Connection Faceplate for the Lamp KI lt gt gt lt gt NG Connector M Decoration Cover Instruction for Installation Diagrams for Installation I How to connect the upper part of remote lighting lifter Choose one 1 The lifter can be installed directly on the ceiling concrete slabs with 4 expansion bolts This is suitable for lifter rated load below 150kg Diagram 1 Expansion Bolt Cushion Cushion Spring Cushion Cushion Nut Spring Cushion Nur Diagram 1 Diag Diagram 2 11 Instruction for Installation pa There is a fixed connector at the center of the upper cover board with a column drilled an across hole on the out cylinder This connector may be connected with the ceiling beam easily This is suitable for lifter rated load below 150kg Diagram 2 There are four corners at the upper cover board of the lifter which is assembling 4 full threaded screws The space between lifter and ceiling is adjustable according to the sunshade height This is suitable for lifter rated load below 250kg Diagram 3 Connection Board 727 Cushion Diagram 3 Instruction for Installation II How to connect the lower part of remote lighting lifter 1 The lamp should be linked with the ring at the center of the lower part of the lift
15. rect method of installation or poor installation or improper transportation done by unqualified personnel b The damage occurred is due to the disassembly by the users or the repair agents non appointed by our company c The users alter the information of purchase invoice or there is no warranty card and purchase invoice when servicing is required d Damage as a result of fire flood abnormal voltage or natural disaster e The damage occurred due to alteration in any way to the product by any unauthorized technician or improper operation f The damage occurred is due to the irresistible factors 3 We are pleased to provide you the whole life service even if it is not the free charge service items Please keep the warranty card and purchase invoice properly The warranty period is subject to the issuing date of the purchase invoice 25 UY qu WARRANTY CARD No 0000001 Address Dee UU _ mm 26 UY qu WARRANTY CARD No 0000001 Address Dee UU _ Err 21 Good Husband Lighting Lifter Makes Cleaning Simple and Convenient Add Maofu Xiayang Industry Area Houmao Community Fujian Province China Tel 86 592 8067637 PC 362000 E mail lightinglifter qmail com Http www remotelightinglifter com 28
16. ty or personal injury due to the user s improper operation so the users have to bear the responsibilities itself Form for the responsibilities of product s quality include repair replace reduce prices remuneration fine make an investigation of the criminal and etc Points to Attention CAUTION OF INSTALLATION Please refer to the diagrams first so as to avoid the damage occurred by improper installation and connection 2 When you complete the installation of the lifter the lifter must have more than 5kg weight on 3 the steel wire rope the installation the lifter will not operate When the lifter is in use people should keep the distance of at least 2 meters to stand or pass underneath a load to avoid the accident occurred The lifter is not allowed to operate when over carrying capacity The lifter should be tested before use The ways of inspection are as follows a To check whether the connection between lifter and the expansion bolt of the ceiling is fixed well and whether the ceiling is with its strong carrying capacity b To check whether the power connection is accord with the requirement and earth wire is reliable c Press DOWN button on the remote control to descend the steel cable first for around 60 seconds then press any key to stop After that press UP to raise the steel cable Please refer to the pagel5 article 4 0 of the installation instruction for other i

Download Pdf Manuals

image

Related Search

Related Contents

TPC Catalog - international sales and marketing  Samsung GT-S3650W Инструкция по использованию  The S300. The Perfect Choice.  . MAXTM  USER MANUAL  Nexacro Platform 14 / Getting Started Tutorial  3Com 3CR990-FX-97 Network Card User Manual  登録ロゴ使用の手引き - 高圧ガス保安協会 ISO審査センター  Sonatic Duo  1 - SimmaRent  

Copyright © All rights reserved.
Failed to retrieve file