1. Battery needs to be replaced Problem Cause Solution Check the circuit protector on the rear of the UPS If it is tripped reset it and restart Overload the UPS UPS Short circuit For further help call your local distributor will Sola Hevi Duty representative or Sola not Hevi Duty Technical Services start 7 Battery disconnected Check for proper connection of battery or or is completely batteries discharged UPS not plugged in Plug in the power cord securely Circuit protector Reset the circuit protector and restart the tripped UPS UPS starts Power not available Have the mains checked by a qualified on battery at mains receptacle electrician but wili Wait until the voltage rises to an not switch to AC put vo tage appropriate level or have the mains checked by a qualified electrician Wait until voltage lowers to an AC overvoltage appropriate level or have the mains checked by a qualified electrician Overload Check the circuit protector on the rear of Short circuit the UPS If it is tripped reset it and restart the UPS If the problem persists disconnect some of the equipment from your UPS the UPS total wattage of your equipment must not shuts Internal UPS fault exceed the capacity of the UPS down For further help call your local distributor Fault Sola Hevi Duty representative or Sola Indicator Hevi Duty Technical Services Lit Make sure that the UPS is operating in a
2. Conducted Immunity EN61000 4 6 Harmonics EN61000 3 2 Flicker EN61000 3 3 Transportation ISTA Procedure 1A Battery Run Times Load 350VA 500VA 650VA 1000VA 408 ee 488 et 10 134 86 77 92 20 64 50 43 46 30 38 38 27 27 40 31 28 21 22 50 22 21 15 16 60 18 16 12 12 70 14 18 9 10 80 12 8 8 90 10 9 6 7 100 8 7 5 5 NOTE Approximate discharge times are in minutes and at 25 C 77 F with a resistive load 24 Product Warranty Registration To register for warranty protection Visit the Technical Support section of our Web site at http www solaheviduty com support index htm Click on the Warranty link and fill in the form This will register your product with Sola Hevi Duty For UPS purchasers The MultiLink software is available for down load in the Products section of our Web site under UPS http www solaheviduty com products UPS software index htm Contact us at 800 377 4384 or via e mail at tech sola hevi duty com with any questions 25 26 EGS SOLA HEVI DUTY Electrical Group EA Technical Support E E a 800 377 4384 International 847 268 6000 www solaheviduty com While every precaution has been taken to ensure accuracy and completeness in this manual Sola Hevi Duty assumes no responsibility and disclaims all liability for damages resulting from us
3. The Automatic Voltage Regulator AVR protects connected equip ment from power spikes and other abnormalities by raising an under voltage boost and lowering an overvoltage buck as needed This keeps the UPS output voltage within the connected equipment s toler ance and accommodates wide mains voltage fluctuations without uti lizing the batteries Bi Directional Converter In normal operation the Bi Directional Converter changes mains AC power into regulated DC power to float charge the battery system This converter is continuously charging the battery whenever the UPS is plugged into a power outlet and mains power is within acceptable limits even if the UPS is turned OFF When mains power fails the Bi Directional Converter draws energy from the battery and inverts it into a regulated stepped sinewave sup plying power for equipment connected to the orange receptacles Battery The S2K unit utilizes valve regulated nonspillable lead acid batter ies To optimize battery life operate the UPS in an ambient tempera ture of 20 25 C 68 77 F WHAT S INCLUDED The S2K unit is shipped with the following items Sola S2K user manual MultiLink software CD MultiLink serial cable 3 0m 10 ft USB cable 1 8m 6 ft RJ 11 cord 2 1m 7 ft Two 2 10A output power cords 2 0m 6 6 ft J MultiLink MultiLink Sola 92 software CD serial cable Unit 3 0m 10 ft USB cable RJ 11 cord T
4. 00 0 15 Battery Mode 0 se ars Be ee ok As we te Len 16 COMMUNICATIONS 000 cece cence ee eee eee 17 DB 9 Connector cym ee 17 Remote Shutdown Via the DB 9 Connector 18 6 6 18 648 18 Interface POM n Cot A GA 18 Data Line Protection 18 MAINTENANCE boone bO EO Pew eee 19 Cleaning the URS wae SA A wha FOR BAe es 19 19 Battery 19 Battery 20 TROUBLESHOOTING 21 Guide to Status Indicators lt 5 Gora aa kes Bee hae ves 21 Troubleshooting Chartcis c2 idede esrara ie eek ee ex 22 SPECIFICATIONS Oa se eee eae yh eee wed 23 Battery Run Times 0 0 ccs 24 Product Warranty 25 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important safety instructions that should be fol lowed during the installation and maintenance of the Uninterruptible Power System UPS and its batteries Please read this manual thor oughly before att
5. network hubs into orange receptacles Surge Prtecion Oniy Plug this type of equipment into black receptacles ONLY 27 Inkjet Scanner printer machine 3 The Sola S2K 230 VAC models are not supplied with an input power lead for connection to the mains supply Additional input output leads can be obtained from your dealer The input power cord must have a minimal cross sectional area of 1mm 10 4 Shut down the load equipment and turn off the mains supply Unplug the load equipment s power input cable from the mains sup ply socket and plug it into the UPS input socket Plug the power input cable into the mains supply socket Connect the supplied IEC 320 C14 output power cable between the load equipment input socket and one of the UPS AC output sockets Connect all load equipment to the UPS in this manner 5 Plug any computers and monitors into the orange battery backed up receptacles Other office machines that do not exceed the capacity of the UPS ink jet printers scanners and fax machines may be plugged into either of the two 2 black receptacles which provide surge protection only 6 Connect Phone Fax DSL Internet Modem devices to data line connectors Serial port for MultiLink cable connection Ee A 7 Press and release the ON OFF Alarm Silence button to turn on the UPS The UPS will beep and the Mains
6. High temp shutdown 0 C to 40 C 32 F to 104 F environment and that it has adequate ventilation NE Consult the MultiLink user manual or MultiLink shutdown contact your LAN administrator UPS not Overload Reduce load providing expected Battery not charged boa iR due to a recent outage Recharge battery time Replace battery 22 SPECIFICATIONS Model Number 2K350 5 S2K500 5 S2K650 5 S2K1000 5 Power Rating VA W 350VA 210W 500VA 300W 650VA 390W 1000VA 600W DIMENSIONS mm in Unit 116x196x222 116x196x222 116x358x222 116x358x222 WxDxH 4 6x7 7x8 7 4 6x7 7x8 7 4 6x14 1x8 7 4 6x14 1x8 7 Shipping 196x310x293 196x310x293 242x500x316 242x500x316 WxDxH 7 7xX12 2x11 5 7 7x12 2x 11 5 9 5x19 7x12 4 9 5x19 7x12 4 WEIGHT kg Ibs Unit 7 0 15 4 7 4 16 3 9 1 20 1 13 2 19 1 Shipping 8 2 18 0 8 5 18 7 11 2 24 7 15 3 33 7 INPUT AC PARAMETERS Surge Protection 660J Voltage Range Without Battery Operation 155VAC 291 VAC DIP switch selectable see DIP switch settings on page 14 Frequency Range 46 5 63 5 Hz 0 1 Hz OUTPUT AC PARAMETERS Output Receptacles 6 IEC 320 C13 Battery 4 IEC 320 C13 orange orange Battery backup surge protection 2 IEC 320 C13 black 2 IEC 320 C13 Surge protection black Surge protection Output Power Cables 2m 6 6 ft detach d IEC 320 C14 Wire Type
7. and releasing the main ON OFF button will start the UPS and an audible alarm sounds briefly The UPS is capable of starting on battery battery start When the UPS is on in either Normal or Battery mode pressing the main ON OFF button for more than two 2 seconds will shut down the UPS An audible alarm sounds briefly When a UPS alarm is active pressing and releasing the main ON OFF button will silence the active audible alarm whether mains power is present or not Once the alarm silence function has been activated all active audible alarms except for low battery overload or over tempera ture conditions will remain silenced until a new alarm con dition is detected NOTE Do not hold ON OFF button down for more than 2 seconds or the UPS will shut down 12 Status Indicators Mains Battery Fault There are three 9 status indicators on the front of the UPS Mains Battery and Fault as shown in the diagram below Each indicator illuminates to specify the status of the UPS see Troubleshooting section for details Mains Indicator Green Amber The Mains Indicator illuminates when the UPS is operating and sup plying power to connected loads green indicates Normal mode amber denotes Buck Boost mode Battery Indicator Green Amber The Battery Indicator illuminates to indicate the UPS is operating on battery green or to signify a battery warning amber Fault Indicator Red Green The Fault In
8. as a diagnostic aid to the operator as shown below Guide to Status Indicators Fault Mains Battery Indicator Indicator Indicator Diagnosis 7 Audible Alarm A LY z Green Normal operation with mains power ON present no beep Green UPS is operating on battery beep every ON 10 seconds Battery test has been initiated no beep Amber __ UPS is operating in Buck Boost mode ON no beep z Green Amber Battery needs to be replaced long beep ON Flashing every minute a Amber Low battery warning beep every half Flashing second Green Green Overload warning load is gt 100 beep Flashing ON every half second Green __ sa Overload shutdown load exceeds UPS Flashing capacity 110 continuous beep Green Green Over temperature overtemp warning ON ON beep every 5 seconds Normal mode Green _ Green Over temperature overtemp warning ON ON beep every 5 seconds Battery mode Green _ z Over temperature overtemp shutdown ON long beep every 5 seconds Red Green UPS is on fault warning continuous Flashing ON beep Red z UPS has failed amp shut down continuous ON beep 21 Troubleshooting Chart If the UPS fails to operate properly turn off the unit and repeat the steps in the Installation section of this manual If the problem per sists refer to the chart below
9. the UPS can signal on battery and low battery using opto couplers When the UPS is operating in Battery mode it can receive a signal from the host com puter system that will shut down the UPS after gracefully shutting down the operating system on the host computer system when the remaining battery run time is low The timing of the signal depends on MultiLink s configuration settings This shutdown signal 5 12VDC must have a duration of at least 2 seconds for the UPS to be shut down DB 9 Pin Assignment Description Low Battery open collector UPS TxD typical RS 232 levels UPS RxD typical RS 232 levels Battery Mode Shutdown 5 12VDC 10 24 mA max Common Any Mode Shutdown short to Pin 5 Low Battery open emitter Mains Fail open emitter 2 3 4 5 6 7 8 9 Mains Fail open collector DB 9 Pin Assignment Collector to Emitter Open Collector Open Emitter Maximum voltage and current on Pins 1 7 8 and 9 is 55 VDC 10 0 mA 17 Remote Shutdown Via the DB 9 Connector The S2K unit can be shut down remotely by shorting Pins 5 and 6 or via Pins 4 and 5 of the DB 9 connector Shutdown Via Pins 5 amp 6 When Pin 6 is shorted to Pin 5 the UPS output is shut off regardless of what mode the UPS is operating in The UPS cannot be started as long as the pins are shorted When the short is removed the UPS out put can be enabled by press
10. 1mm HOSW F 3G Voltage Normal mode Nominal 220 230 240VAC 10 Voltage Battery mode 230VAC 8 Output Current 15 2 1A 2 8A 4 3A Waveform Battery mode Stepped Sinewave Frequency 50 Hz or 60 Hz auto sensing Normal batters modes gt 100 Overload Shutdown gt 110 BATTERY PARAMETERS Type Valve regulated nonspillable lead acid Quantity x Voltage x Rating 1 x12Vx7Ah 1 x12Vx9Ah 1 x12Vx9Ah 2 x12Vx7 5Ah Transfer Time 4 6 ms typical Backup Time At 25 C 77 F resistive loading with fully charged batteries Full Load 8 minutes 7 minutes 5 minutes 5 minutes Half Load 22 minutes 21 minutes 15 minutes 16 minutes Recharge Time 6 hours to 90 of rated capacity after full discharge into a resistive load 23 ENVIRONMENTAL Operating Temperature 0 C to 40 C 32 F to 104 F Storage Temperature 15 C to 40 C 5 F to 104 F Relative Humidity 0 to 95 non condensing Operating Elevation Up to 3000m 10 000 ft at 35 C 95 F without derating Audible Noise lt 40 dBA at 1 meter AGENCY Safety EN50091 1 1 CE compliance mark Surge EN61000 4 5 Level 3 Criteria A ESD EN61000 4 2 Level 3 Criteria A Susceptibility EN61000 4 3 Level 3 Criteria A Electrical Fast Transient Burst EN61000 4 4 Level 3 Criteria A Emissions EN50091 2 Class B
11. ES sow HEVI DUTY Electrical Group S2K UPS USER MANUAL SOLA S2K S p se i Line Interactive 350 1000 VA 230V TABLE OF CONTENTS IMPORTANT SAFETY 1 INTRODUCTION amp SYSTEM 5 Prone View of WPS rescat oci ted ae z dw od oe WE 6 Rear View of UPS eai kwi 2 7 MAJOR 8 Transient Voltage Surge Suppression TVSS amp EMI RFI Filters Seti RODE AA Ge tha 8 Automatic Voltage Regulator 0 0 0 0 8 Bi Directional 8 Battery ce Sis teat E gts Mee 8 WHAT S INCLUDED ea eee eRe eA 9 INSTALLATION ul oa oe obese ee eae 10 12 ON OFF Alarm 6 12 Status Indicators Mains Battery Fault 19 Mains Indicator 13 Battery Indicator 13 Fault Indicator Red Green 0 0 00 13 Location and Status of 13 Transfer Voltage Selectors DIP Switches 14 15 Normal Mode Se eae ds 15 Buck Boost
12. Indicator will illuminate green 8 Turn on connected equipment 9 Communication options see Communications section for details Option 1 Serial Communications Serial communications provides parametric data for example input voltage and battery voltage a Connect MultiLink serial cable included with the UPS to commu nications port b Install the MultiLink software the software and installation instructions as well as the user manual are on the CD included in the Sola S2K package Option 2 Contact Closure Communications Contact Closure communications provides on battery and low bat tery signals for orderly shutdown a Refer to the MultiLink user manual for instructions on making your own contact closure cable b Install the MultiLink software the software and installation instructions as well as the user manual are on the CD included in the Sola S2K package Option 3 USB Communications a Connect USB cable provided with the UPS to the USB ports on the S2K and your computer The S2K will work automatically with your built in power management software on Windows XP and 2000 and Mac OS 10 2 or later see USB Interface Port section for details 11 CONTROLS AND INDICATORS ON OFF Alarm Silence Button O OFF Alarm Silence 4 This button controls output power to the connected load and has three functions ON OFF Alarm Silence ON OFF Alarm Silence When the UPS is off pressing
13. NING ELECTRICAL PRECAUTIONS This UPS should not be supplied from electrical power sys tems of the IT Impedance 4 Terre type IEC 364 Elec trical Installation of Buildings The UPS must be earthed grounded at all times during operation Connect only to a mains supply socket outlet with an earth ground connection CAUTION Although your UPS has been designed and manufactured to assure personal safety improper use may result in electrical shock or fire To ensure safety please observe the following rules Turn off and unplug your UPS before cleaning Do not use liquid or aerosol cleaners A dry cloth is recommended to remove dust from the surface of your UPS Do not install or operate your UPS in or near water Do not place your UPS on an unstable cart stand or table Do not place your UPS in direct sunlight or near heat emitting sources Never block or insert any objects into the ventilation holes or other openings of the UPS Keep all vents free of dust accumulation that could restrict airflow Do not place the UPS power cord in any area where it may be damaged by heavy objects Placing magnetic storage on the top of the UPS may result in data corruption AN CAUTION BATTERY HANDLING PRECAUTIONS Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and required precautions Keep unauthorized personnel away from the batteries A battery can present a risk of elect
14. S OF OPERATION Normal Mode During Normal mode operation the S2K unit supplies conditioned computer grade power to the connected equipment mains power passes through the TVSS circuitry and the EMI RFI filters and then through the Bi Directional Converter to connected equipment When the UPS is in Normal mode the Mains Indicator illuminates green Mains Indicator Green The SZK unit continuously monitors the batteries to maintain them in a fully charged state The battery charger operates whenever AC power is present even if the UPS is switched off By default the UPS is set to perform an automatic battery test after it has been operating continuously for two 2 weeks The interval at which the UPS will perform a battery test can be configured via MultiLink Buck Boost Mode The Automatic Voltage Regulator AVR circuitry compensates for fluctuations in mains power such as voltage surges and sags When the SZK unit detects an abnormality it raises the undervoltage boost or lowers the overvoltage buck as needed The AVR operates automatically and maintains the output voltage to the connected criti cal equipment without utilizing the batteries When the UPS is in Buck Boost mode the Mains Indicator illumi nates amber Mains Indicator Amber A 15 Battery Mode The UPS switches to Battery mode in the event of an extreme voltage frequency condition or complete mains failure
15. The battery system supplies power through the Bi Directional Converter to generate power for connected equipment When the UPS is in Battery mode the Battery Indicator illuminates green and an alarm sounds every 10 seconds A Battery Indicator Green When a low battery condition occurs the Battery Indicator changes to flashing amber and the alarm sounds every half second Low battery warning is defaulted to two 2 minutes but can be configured via Mul tiLink For more information refer to Troubleshooting section A Battery Indicator flashing Amber CAUTION Turning off the UPS while in either Normal mode or Battery mode will result in the loss of output power NOTE Once mains power is restored the UPS resumes normal operation At this time the battery charger begins recharging the battery The UPS is capable of OFF State charging i e with mains power the UPS will charge the batteries as long as it is plugged in 16 COMMUNICATIONS DB 9 Connector The UPS has a DB 9 9 pin female connector on the rear to allow UPS status communications with a computer system running MultiLink software The DB 9 is capable of supplying serial communication on battery and low battery signals MultiLink UPS monitoring and shut down software is shipped with the UPS along with a 3m 10 ft DB 9 cable required for running MultiLink When MultiLink is installed on the host computer
16. ake occasionally e Wipe the cover periodically with a dry cloth Maintaining Batteries The batteries are valve regulated nonspillable lead acid and must be kept charged to retain their design life The UPS continuously charges the batteries when connected to the mains supply even while the UPS is switched off When storing the UPS it is reeommended to plug in the UPS for at least 24 hours every four to six months to ensure full recharge of the batteries Battery Replacement AN CAUTION A battery can present a risk of electrical shock and high short circuit current The following precautions should be observed before replacing the batteries Remove rings watches and other metal objects Do not lay tools or other metal objects on top of the bat teries Ifthe battery replacement kit is damaged in any way or shows signs of leakage contact your local distributor or Sola Hevi Duty representative immediately Do not dispose of batteries in a fire The batteries may explode Dispose of old batteries according to local codes This UPS is equipped with internal hot swappable batteries that the user can replace without shutting down the UPS or connected loads NOTE Caution should be exercised when replacing the batteries because the load is unprotected from disturbances and power outages during this procedure 19 Battery Replacement Procedure Replacement requires removing the battery cover plate on
17. dicator illuminates when the UPS detects a problem red for an internal UPS fault green for overload and over temperature conditions Location and Status of Indicators Mains Indicator Green Normal operation Amber Buck Boost mode Fault Indicator Green Overload Over temperature Battery Indicator Red UPS fault Green On battery Amber Battery warning NOTE See Troubleshooting section for details 13 Transfer Voltage Selectors DIP Switches DIP Switches Rear of UPS Communication Port Battery Back up Surge Protection Phone Fax Modem Protection The two position DIP switch control on the rear panel shown above allows the operator to select the mains transfer voltage at which the UPS will switch to battery power DIP switch positions for each volt age setting are as follows DIP switch settings Left Right Nominal Mains Input Range Setting TUp TUp 230VAC 163 282VAC default 1 Up Down 220VAC 155 270VAC 4 Down Tup 240VAC 171 291VAC 4 Down 4 Down 230VAC 163 282VAC CAUTION Never change the voltage settings while the UPS is ON and powering connected loads Change DIP switches only when the UPS is OFF CAUTION To ensure protection of the connected equipment the DIP switch settings should match the nominal mains input voltage DIP switch settings not matching the nominal mains could potentially damage connected equipment 14 MODE
18. e of this information or for any errors or omissions 2003 Sola Hevi Duty All rights reserved throughout the world Specifications subject to change without notice Sola Hevi Duty name and logo are registered trademarks of EGS Electrical Group LLC Intellislot is a registered trademark of Emerson Network Power MultiLink is a trademark of Emerson Network Power All names referred to are trademarks or registered trademarks of their respective owners S2K2300503R0 Rev 1 7 03
19. empting to install or operate this UPS Read all safety installation and operating instructions before operat ing the UPS Adhere to all warnings on the unit and in this manual Follow all operating and user instructions This equipment is designed for Commercial Industrial or Residential use Sola Hevi Duty neither recommends nor knowingly sells this product for use in life support applications or with other designated critical devices This equipment can be installed and operated by individuals without previous training AN WARNING A SAFETY PRECAUTIONS There are no user serviceable parts inside this UPS except the internal battery pack Refer all UPS service to quali fied service personnel Do not attempt to service this prod uct yourself Output receptacles on the UPS are electrically live if the UPS is switched on even if the UPS is not plugged into a Mains supply The ON OFF button on the UPS does not electrically isolate the internal parts Some components are live even when Mains power is disconnected To isolate the UPS switch off the UPS first then unplug it from the Mains Opening or removing the cover may expose you to lethal voltages within this unit even when it is apparently not operating and the input wiring is disconnected from the electrical source Observe all CAUTION and WARNING statements in this manual and on the unit Failure to do so may result in serious injury or death Never work alone WAR
20. ing the ON OFF Alarm Silence button Shutdown Via Pins 4 amp 5 While the UPS is operating on battery with no battery test in progress a 5 12 VDC signal for 2 seconds or longer is required to sig nal a shutdown Signals for less than 2 seconds are ignored After Pin 4 receives the shutdown signal a 2 minute shutdown timer inside the UPS begins a countdown The timer cannot be stopped If mains power returns during the 2 minute timer countdown the shut down timer continues until the end of 2 minutes and then the UPS turns off By default autorestart is enabled so the UPS will restart after 10 seconds If autorestart is disabled via MultiLink software the UPS remains off until a manual restart USB Interface Port The S2K unit has a USB interface port for communication that will work with most power management software and provide UPS sta tus and management of the automatic orderly shutdown of the com puter The S2K s USB communications meets HID standard version 1 11 Data Line Protection Connectors Data line IN amp OUT connectors are located on the rear of the UPS and provide transient voltage surge suppression TVSS for Phone Fax DSL Internet Modem devices 18 The Sola S2K UPS requires very little maintenance Follow these practices to prevent problems Cleaning the UPS The following will help ensure trouble free operation for years Vacuum dust from the ventilation int
21. l in a clean environment free from conductive contaminates moisture flammable liquids gases or corrosive substances Provided are a MultiLink cable and a USB cable for connection to a computer Do not use the MultiLink cable for other applications Store in a safe place if not required at this time When using the communication features on this UPS ensure the cabling connected to the DB 9 or UPS communications ports are kept separated from the power leads to the UPS input and output INTRODUCTION amp SYSTEM DESCRIPTION Congratulations on your choice of the Sola S2K series Uninterruptible Power System UPS It provides filtered AC power to sensitive elec tronic equipment and other critical loads The S2K unit is a line interactive UPS designed for an office environ ment It provides perfect power protection for PCs point of sale sys tems network and similar electronic equipment It offers a configurable input voltage window allowing you to precisely match your equipment s input power Three communications options are available serial connection contact closure and USB The S2K unit is available in four 4 sizes 350 500 650 and 1000VA at 120 VAC and 230 VAC Sola S2K models are available for 120 VAC and 230 VAC supply volt ages and loads Please verify that this model matches your AC Mains and load voltage requirements Front View of UPS Power ON OFF Alarm Silence SOLA Mains Indicator Green A
22. mber Fault Indicator Red Green Battery Indicator Green Amber For details see Controls and Indicators section Rear View of UPS 3508 500VA Models DB 9 port Orange output receptacles Battery backup surge protection Battery cover plate on rear of 350 amp 500VA models x 650 amp 1000 VA Models nore DB 9 port Orange output receptacles Battery backup surge protection NOTE Bottom two receptacles __ on 1000VA models only a 650 amp 1000VA models Battery cover plate bottom of unit for DIP switches Data Line Protection Connectors 2 Phone Fax DSL internet Modem devices Black output receptacles 2 Surge protection only Input circuit protector DIP switches Data Line Protection Connectors 2 Phone Fax DSL internet Modem devices Black output receptacles 2 Surge protection only Input circuit protector For details see Installation section Controls and Indicators section Communications section MAJOR COMPONENTS Transient Voltage Surge Suppression TVSS amp EMI RFI Filters These UPS components provide surge protection and filter electro magnetic interference EMI and radio frequency interference RFI They minimize surges or interference present in the mains line and keep the sensitive equipment protected Automatic Voltage Regulator
23. rical shock and high short circuit current The following precautions should be observed when working on batteries Remove watches rings and other metal objects e Use tools with insulated handles Do not dispose battery or batteries in a fire The battery may explode Do not open or mutilate the battery or batteries Released electrolyte is harmful to skin and eyes It may be toxic When replacing the battery use same number and type of battery as the suitable recommended type of battery listed in specification table in back of this manual Handle transport and recycle batteries in accordance with local regulations WARNING If your UPS demonstrates any of the following conditions turn off and unplug your UPS from the outlet and contact your local distributor Sola Hevi Duty representative or Sola Hevi Duty Technical Services The power cord is damaged Liquid has been spilled on the UPS The circuit breaker or fuse opens frequently The UPS does not operate in accordance with the user manual Electromagnetic Compatibility The Sola S2K series complies with the requirements of the EMC Directive 89 336 EEC and the pub lished technical standards Continued compliance requires installa tion in accordance with these instructions and use of Sola Hevi Duty approved accessories only Environmental Operate the UPS in an indoor environment only in an ambient temperature range of 0 C to 40 C 82 F to 104 F Instal
24. the back or bottom of the UPS No tools are needed To replace the batteries 1 Remove the bat Figure 1 Figure 2 tery cover plate on the back bot tom of the UPS Figure 1 Pull the white tabs towards you to remove the battery from the UPS Figure 2 N w Disconnect the insulated con Figure 3 Figure 4 nectors from the battery termi nals Figure 3 4 Insert a new battery pack and push the connectors onto the battery ter minals black to black amp red to red Figure 4 NOTE There may be a small spark at the battery terminals when reconnecting the connectors This is normal and will not harm you or the UPS Push the battery Figure 5 Figure 6 pack into the UPS Figure 5 6 Reattach the battery cover plate Figure 6 20 TROUBLESHOOTING The information below indicates various symptoms a user may encounter in the event the S2K unit experiences a problem Use this information to determine whether external factors caused the prob lem See Troubleshooting Chart for suggested remedy 1 The Fault indicator illuminates indicating the UPS detected a problem Mains Indicator Fault Indicator Indicator Battery 2 An alarm sounds alerting that the UPS requires attention The alarm can be silenced except for low battery overload warning and over temperature warning conditions Mains and or Battery indicators may be illumi nated
25. wo 2 10A output 1 8m 6 ft 2 1m 7 ft power cords 2 0m 6 6 ft INSTALLATION This UPS is designed for data processing equipment Maximum load must not exceed that shown on the UPS rating label Do not connect equipment that could overload the UPS or draw half wave current from the UPS for example electric drills vacuum cleaners laser printers or hair dryers Your total load earth leakage current must not exceed 3 5 mA Most data processing equipment meets this require ment if you use no more than two pieces of equipment If uncertain about your load consult your local distributor Sola Hevi Duty repre sentative or Sola Hevi Duty Technical Services 1 Visually inspect the UPS for freight damage Report damage to the carrier and your local distributor Sola Hevi Duty representative or Sola Hevi Duty Technical Services 2 Decide where to place the S2K unit Find a location that is near an easily accessible mains outlet Install the UPS indoors in a con trolled environment where it cannot be accidentally turned off Place it in an area of unrestricted airflow around the unit away from water flammable liquids gases corrosives and conductive contaminants Maintain a minimum clearance of 100mm 4 inches on each side of the UPS Maintain an ambient temperature range of 0 C to 40 C 32 F to 104 F NOTE UPS operation in temperatures above 25 C 77 F reduces battery life Plug computers monitors amp