1. USER MANUAL AD203 amp AD204 EC Testers e Direct readings better resolution Automatic temperature compensation e Easy to read display www adwainstruments com Dear Customer Thank you for choosing an ADWA product Please read carefully this manual before starting operations For additional technical information please e mail us at sales adwainstruments com WARNING The enclosed product is intended for use by persons know ledgeable in safe laboratory practices Failure can result from surface damage improper pressure or temperature or use with improper chemicals Information concerning limitations of ADWA products can be obtained from ADWA Kft OPERATION 1 Remove the protective cap from the bottom of the tester 2 Press ON OFF button to turn the tester on 3 Place the tip of the tester into the sample to be measured 4 Record the conductivity value The tester will automatically compensate temperature variations 5 Press ON OFF button to turn the tester off CALIBRATION 1 Switch the tester on by pressing the ON OFF button 2 Place the tip of the probe into the calibration solution and wait for reading to stabilize For AD203 use the 1413 uS cm conductivity solution For AD204 use the 12 88 mS cm conductivity solution 3 Using the screwdriver supplied adjust the calibration trimmer on the back of the tester to match the calibration standard value
2. For AD203 1413 uS cm For AD204 12 88 mS cm 4 The tester is now ready to use ALWAYS USE A FRESH SOLUTION FOR CALIBRATION MAINTENANCE If readings became unstable clean the probe by rinsing it in alcohol for ten minutes If the reading fades or disappears batteries should be replaced BATTERY REPLACEMENT Open the battery compartment at the top of the tester Place the batteries noting the polarity listed in the battery compartment ACCESSORIES A70031P 1413 wS cm solution 20 ml sachet 25 pcs A70030P 12 88 mS cm solution 20 ml sachet 25 pcs OPERATION 1 Remove the protective cap from the bottom of the tester 2 Press ON OFF button to turn the tester on 3 Place the tip of the tester into the sample to be measured 4 Record the conductivity value The tester will automatically compensate temperature variations 5 Press ON OFF button to turn the tester off CALIBRATION 1 Switch the tester on by pressing the ON OFF button 2 Place the tip of the probe into the calibration solution and wait for reading to stabilize For AD203 use the 1413 uS cm conductivity solution For AD204 use the 12 88 mS cm conductivity solution 3 Using the screwdriver supplied adjust the calibration trimmer on the back of the tester to match the calibration standard value For AD203 1413 uS cm For AD204 12 88 mS cm 4 The tester is now ready to use ALWAYS USE A FRESH SO
3. LUTION FOR CALIBRATION MAINTENANCE If readings became unstable clean the probe by rinsing it in alcohol for ten minutes If the reading fades or disappears batteries should be replaced BATTERY REPLACEMENT Open the battery compartment at the top of the tester Place the batteries noting the polarity listed in the battery compartment ACCESSORIES A70031P 1413 wS cm solution 20 ml sachet 25 pcs A70030P 12 88 mS cm solution 20 ml sachet 25 pcs
4. SPECIFICATIONS AD203 Temp compensation Environment Battery Life Type Dimensions 0 to 1999 uS cm 2 full scale 0 to 50 C 95 relative humidit AD204 Resolution Accurac Temp compensation Environment Battery Life Type Dimensions ISTRAD203R1 06 09 0 00 to 19 99 mS cm 0 01 mS cm 2 full scale 0 to 50 C 95 relative humidit USER MANUAL AD203 amp AD204 EC Testers Direct readings better resolution Automatic temperature compensation e Easy to read display www adwainstruments com Dear Customer Thank you for choosing an ADWA product Please read carefully this manual before starting operations For additional technical information please e mail us at sales adwainstruments com WARNING The enclosed product is intended for use by persons know ledgeable in safe laboratory practices Failure can result from surface damage improper pressure or temperature or use with improper chemicals Information concerning limitations of ADWA products can be obtained from ADWA Kft SPECIFICATIONS AD203 Temp compensation Environment Battery Life Type Dimensions 0 to 1999 uS cm 2 full scale 0 to 50 C 95 relative humidit AD204 Resolution Accurac Temp compensation Environment Battery Life Type Dimensions ISTRAD203R1 06 09 0 00 to 19 99 mS cm 0 01 mS cm 2 full scale 0 to 50 C 95 relative humidit
Download Pdf Manuals
Related Search
Related Contents
warning AVERTISSEMENT - Le Proscenium - Octagon 取扱説明書 - TOTO SERVICE MANUAL DISHWASHERS - M Sony XM-N1004 Operating Instructions Instruction Manual MANUAL BBS-BR.cdr - Casa dos Bebedouros Model No: EY75A1/EY75A2 Copyright © All rights reserved.
Failed to retrieve file