Home
Anaheim Scientific H400 Anemometer with Temperature
Contents
1. Fig 1 into the Input Socket 4 8 Fig 1 2 Power ON the meter by pressing the Power Button 4 2 Fig 1 3 Select the desired air velocity unit of measure by pressing the unit Button 4 5 Fig 1 Select the desired temperature units by pressing the C F Button 4 6 Fig 1 4 Hold the Probe Handle 4 12 Fig 1 face the Vane Probe Head 4 11 Fig 1 to the air flow source to be measured The air velocity and temperature willboth be displayedon the LCD 5 Important note Ensure the yellow dot mark faces into the air flow source to be measured 4 3 Data Hold amp Data Record 1 Data Hold a During a measurement press the Hold Button 4 3 Fig 1 to hold the displayed value on the LCD The HOLD symbol will also be displayed on the LCD b Pressing the Hold Button 4 3 Fig 1 will release the data hold function 2 Data Record Max Min record the maximum and minimum readings press the REC Button 4 4 Fig 1 The REC symbol will be displayed on the LCD By pressing the REC Button 4 4 Fig 1 you can toggle through the Max and Min values b To delete the recorded values press and hold the Hold Button 4 3 Fig 1 for about3 seconds To stop using REC function press and hold the REC Button 4 4 Fig 1 for atleast 3 seconds 5 Auto Power Off Disable This instrument has a Auto Power Off function that can prolong
2. Yorba Linda CA 92887 www anaheimscientific com 714 921 9095 Include with the returned instrument your complete return shipping address contact name phone number and description of problem 9 Limited Two Year Warranty Anaheim Scientific w arrants to the original purchaser that its products and the component parts thereof w ill be free from defects in workmanship and materials for a period of two years from date of purchase from an authorized Anaheim Scientific distributor Anaheim Scientific will w ithout charge repair or replace at its option defective product or component parts Returned product must be accompanied by proof of the purchase date in the form of a sales receipt To obtain w arranty coverage in the U S A this product must be registered by completing the w arranty registration form on www anaheimscientific com within fifteen 15 days of purchase Exclusions This warranty does not apply in the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs The warranty is void if the serial number is altered defaced or removed Anaheim Scientific shall not be liable for any consequential damages including without limitation damages resulting from loss of use Some states do not allow limitations of incidental or consequential damages So the above limitation or exclusion may not apply to you This w arranty gives you specific rights and you may have other rights which vary f
3. battery The meter will shut off automatically if none of the buttons are pressed in approx 10 To disable this function select the memory record function during a measurement by pressing REC Button 4 4 Fig 1 6 RS232 PC Serial Interface Information This instrument has RS232 PC serial interface via a 35 mm terminal 4 12 Fig 1 The dat outputis a 16 digit streamwhich can be utilized for user s specific application 5232 lead wit the following connection will be required to link the instrument with the PC serial port Visit www anaheimscientific comto see any available downloadabk software for your instrument Meter PC 9W D Connector Center Pin Pin 4 3 5 mm jack plug Ground shield Pin 2 2 2K resister Pin 5 The 16 digit data stream will be displayed in the following format 15 014 013 D12 011 D10 D9 D8 D7 D6 D5 D4 D2 0100 eee ee ach digit indicates the following status ms 08 mpn 12 i Decimal Point DP position fromright to left 0 No DP 1 1 DP 2 2 DP 3 3 DP Display reading D1 LSD D8 MSD Example If the display reading is 1234 then D8 to 01 is 00001234 End Word m D12 amp D11 D8 to D1 po eee aud Rate arly ata DIF 7 Battery Replacement 1 When LCD display shows the 22h low battery symbol It is necessary to replace the battery The specifications listed for this instrument do not apply when the low
4. battery symbol is displayed 2 Open the Battery Compartment 4 9 Fig 1 by first loosening the Battery Cover Screws 4 14 Fig 1 3 Replace the batteries with good batteries noting the correct polarity Replace Battery Compartment 4 9 Fig 1 and Battery Cover Screws 4 14 Fig 1 Ensure the cover is securely fastened 8 Service Information Warranty Service Pease return the product in the original packaging with proof of purchase to the address below Clearly state in writing the performance problem and return any leads probes connectors and accessories that you are using with the device Non Warranty Service Return the product in the original packaging to the address below Clearly state in w riting the performance problem and return any leads probes connectors and accessories that you are using w ith the device Customers not on open account must include payment in the form of a money order or credit card For the most current repair charges please visit www anaheimscientific com and click on service repair Return all merchandise to Anaheim Scientific w ith pre paid shipping The flat rate repair charge for Non Warranty Service does not include return shipping Return shipping to locations in North American is included for Warranty Service only For overnight shipments and non North American shipping fees please contact Anaheim Scientific Anaheim Scientific 22820 Savi Ranch Parkw ay
5. ANAHEIM SCIENTIFIC Division of BK PRECISION INSTRUCTION MANUAL Models H400 Anemometer Table of Content 1 Product IMtrOduction 3 THA FOAMS sii estivesissessavernceccasesavatierecciaceassaass 3 1 2 ApplicatonS 3 2 Safety 4 2 CAUNONS 4 2 2 Safety SYM bOB usdadietataselahensivind stubsihinacetes sa 4 3 SPC CAT ONS escciscscecessivssecssecsecersevesessistedecivvivsnaiece 5 4 Operation 6 4 1 Unit Diagram gece csi tects ec eres 6 4 2 Air Velocity Temperature Measurement 7 4 3 Data Hold Data 7 5 Auto Power Off Disable 7 6 RS232 PC Serial Interface Information 7 Battery 9 8 Service IMform ation 9 9 Warranty INfOrm ation 10 To see all available accessories and downloadable software please visit www anaheimscientific com 1 1 Features Measure both temperature and air flow Selectable C amp F measure ments Displays air flow in ms kmh mph knots amp ft min Two year warranty 2 2 Applications HVAC Energy aud
6. emperature sensor Precision thermistor Sampling Time of Data Manual Pushing the data loggerbutton once wil Logger save dataone time 1 2 10 30 60 600 1800 3600 Auto seconds Resolution 0 1ms gt 10ms k Air Velocity Temperature Measuring Range 0 to 50 C 32 to 122 F 0 01 208 C 15 S S Data Hold Display freeze 5 Operating Environment 32 to 122 F 0 to 50 C lt 80 6 Pieces of DC 1 5V Batteries UM4 AAA or Power Supply equivalent Weight approx 0 8505 387g Dimensions approx Main instrument 6 9 x 27 x 1 7 174 68x 42mm Sensor probe diameter 2 8 72mm Included Instruction manual battery carrying case Note Accuracy applicable in environments with RFI lt 3V M with Hz lt 30MHz and temperatures between 20 C to 26 C Specifications and information are subject to change without notice Please visit www anaheimscientific com for the most current product information 4 Operation Instructions 4 1 Unit Diagram Fig 1 4 1 LCD Display 4 9 Battery Compartment 4 2 Power Button 4 10 Stand 4 3 Hold Button 4 11 Vane Probe Head 4 4 Record MAX MIN Button 4 12 Probe Handel 4 5 Unit Button 4 13 Probe Plug 4 6 C F Button 4 14 Battery Cover Screw 4 7 RS232 Socket 4 15 Tripod Screw Mount 4 8 Probe Input Socket 4 2 Air Velocity Temperature Measurement 1 Insert Probe Plug 4 13
7. its Environmental experiments Building maintenance Agriculture 2 Safety Information A Read the follow ing safety information carefully before attempting to operate or service the meter Only qualified personnel should perform repairs or servicing not covered in this manual 2 1 Cautions DO NOT submerge the products mentioned in this manual in water any other types of liquids This product is not designed for use in medical applications The product can only be used to measure body temperature simply for reference 2 2 Safety Symbols Dangerous refer to this manual before using the meter A Conforms to requirements of European Union and European Fare Trade Association EF TA Battery levelis low Don t dispose this product as unsorted municipal waste This instrument conforms to the follow ing standards EN61326 Electrical equipment for measurement control and laboratory use 1EC61000 4 2 Electrostatic discharge immunify test 1EC61000 4 3 Radiated radio frequency electromagnetic field immunity test 1EC61000 4 8 Power frequency magnetic field immunity test 3 Specifications 5 Digit LCD with bar graph indicator Unit of Measurement ms meters per second kmh kilometer per hour ft min feet per minute knots nautical miles per hour mph mile h miles per hour Temp C F Data hold Sensor Structure Air velocity sensor Conventional twisted vane armand low friction ball bearing design T
8. rom state to state Anaheim Scientific 22820 Savi Ranch Parkw ay Yorba Linda CA 92887 www anaheimscientific com 714 921 9095 10 Anaheim Scientific 22820 Savi Ranch Par kw Yorba Linda CA 92887 U S A www anaheimscientific com Printed in Tawan Ver 1 0 0606 2006 Anaheim Scientific Corporation
Download Pdf Manuals
Related Search
Related Contents
Tandberg Data 3530-LTO tape drive Saeco Syntia Super-automatic espresso machine HD8838/04 Samsung SCH-S390 User Manual Sistema de Control Gubernamental SOA 038 Marmitek MegaCam 1 InFocus SP-CEIL-UNIV User's Manual Land based Aquaculture 2014 - 2015 Catalogue ASUS 1215P-MM27-BK netbook Mappus bleibt hart Copyright © All rights reserved.
Failed to retrieve file