1. IR and Rod Thermometer Model SPK3 with Laser Take temps in close or at range Point the laser for 8 1 IR infrared temperatures or push the rod through ducts for dry bulb air temperatures T1 T2 mode works across both IR and Rod modes Features E Use for walk around or in duct checks E Max min Hold and T1 T2 functions E Hangs from duct walls or air register fins E Sharp narrow tip for insertion into duct work E Display flips IR ROD for easy viewing E Clips to your pocket or bag C E ey E Backlight and laser sight Specifications Probe length 94mm 3 75 long Operating environment 32 F to 104 F lt 90 RH Storage environment 14 F to 140 F lt 70 RH Battery 2 x AAA installed Battery life alkaline 40 hrs IR 750 hrs ROD Auto off 3 min 15 min T1 T2 mode IR range 20 F to 932 F 30 C to 500 C Best resolution 0 5 F 0 2 C Accuracy 4 F 2 C 20 F to 32 F 73 F lt 80 RH 3 F 1 5 C 32 F to 50 F calibrated 30cm 2 F 1 C 50 F to 104 F 3 F 1 5 C or 1 5 of rdg whichever is greater 104 F to 932 F Field of view D S 8 1 Response time 0 5 seconds Wavelength 8um to 14um Emissivity E 0 95 Rod range 40 F to 257 F 40 C to 125 C Best resolution 0 1 F 0 1 C Accuracy 1 F 0 5 C 32 F to 122 F 73 F lt 80 RH 2 F 1 0 C lt 32 F gt 122 F Fieldpiece Instruments Inc 2014 Response time 20 seco
2. T2 to lock in T2 and view T1 T2 4 Hold T1 T2 to exit Units Hold T1 T2 and M m to toggle F and C Max min 1 Press M m to begin recording maximum and minimum values 2 Press M m to cycle through maximum minimum and real time MAXMIN blinks values 3 Hold M m to clear recorded values and exit Battery Replacement When your meter s battery is low the laser and LCD brightness will dim Lob will display and meter will power off Open the bottom battery cover with a mini screwdriver and replace the 2 AAA batteries Infrared Test Tips The infrared sensor is very sensitive to ambient temperature changes For best accuracy do not quickly go from a hot truck to a cold basement It also helps to keep hands away from sensor When something is hot it radiates infrared IR energy The SPK3 collects infrared energy from a circular viewing area and measures the total amount of energy collected The SPK3 converts the total energy measured to a temperature Distance doesn t matter because the further you go from the target the increase in area seen by the sensor exactly balances the loss of energy collected from a given area If you want to get the temperature of something small such as a pipe you must get close enough so the pipe takes up the whole viewing area circle Otherwise the pipe and the background temperatures will be averaged into the reading Though for best results it s best to measure from at l
3. east 1 foot 30cm of your target The accuracy of many infrared temperature measuring systems is adversely affected by ambient temperature You need to be aware that if the target surface is reflective enough it may reflect infrared from other objects For example if you take a reading of a shiny metal surface the infrared energy of your face may reflect enough energy off the surface to affect the reading Emissivity of the target surface also affects the temperature reading For a given temperature the higher the emissivity the higher the reading The lower the emissivity the lower the reading Emissivity of a surface indicates how easy it is for the infrared to get out Emissivity for a dull black surface is high nearly 100 so it s easy for the infrared to get out Emissivity for a shiny surface can be much lower If the emissivity is low the measured temperature will be lower than actual For relative readings of the same kind of surface this isn t a problem For some applications it may be neces sary to spray dull black paint on the target to insure a more accurate reading For best accuracy use contact sensors thermocouples thermistors etc anytime you take a temperature measurement Infrared instruments should only be used when you aren t able to touch the surface to be measured Limited Warranty This meter is warranted against defects in material or workman ship for one year from date of purchase Fieldpiece w
4. ill replace or repair the defective unit at its option subject to verification of the defect This warranty does not apply to defects resulting from abuse neglect accident unauthorized repair alteration or unreasonable use of the instrument Any implied warranties arising from the sale of a Fieldpiece product including but not limited to implied warranties of merchantability and fitness for a particular purpose are limited to the above Fieldpiece shall not be liable for loss of use of the instrument or other incidental or consequential dam ages expenses or economic loss or for any claim of such damage expenses or economic loss State laws vary The above limitations or exclusions may not apply to you For Service In the USA call Fieldpiece Instruments for one price fix all out of warranty service pricing Send check or money order for the amount quoted Send the meter freight prepaid to Fieldpiece Instruments Send proof of date and location of purchase for in warranty service The meter will be repaired or replaced at the option of Fieldpiece and returned via least cost transportation Outside of the USA please visit www fieldpiece com for service contact information Fieldpiece Designed in USA
5. nds Metco in USA Model ii I Hl 6 MADE IN CHINA Description Use the SPK3 IR and Rod Thermometer to quickly mea sure surface temperatures or to check the dry bulb inside duct work It has an 8 1 field of view which means at 16 feet away you are seeing the average temperature of a 2 foot circle The backlit display automatically flips in ROD mode for hanging on duct walls WARNING A Never point the laser towards the eyes as permanent eye damage may occur Use extreme caution when using the laser Keep out of the reach of children Be careful around mirror surfaces since mirrors can reflect the laser Looking into the reflected laser is just as damaging as looking directly at the laser CE ce K WEEE Operation Press MEAS HOLD to power on into IR mode Press ROD to flip the display and view probe temp There is no OFF button Your SPK3 will turn off auto matically after 3 minutes 15 min in T1 T2 mode IR Infrared Mode 1 Hold the MEAS button while aiming the sensor at the surface you want to measure 2 The surface temperature will automatically be held on the display when MEAS is released ROD Thermistor Mode 1 Display flips so it can be seen when hanging 2 Press MEAS HOLD to freeze the display T1 T2 Works between both IR and ROD 1 Press T1 T2 to view T1 Note You must hold MEAS if in IR mode 2 Press T1 T2 to lock in T1 and switch to T2 3 Press T1