Home
WPC-765/WPC-765E
Contents
1. Electrical shocks or fires may occur from overloading Do not touch the power source during a thunderstorm If your hands are wet do not touch the plug Use your thumb and index finger grip firmly on the power cord to disconnect from the electrical socket By pulling the power cord may result in damaging it If the unit is not going to be in use for an extended period of time remember to disconnect the unit Please use only the power cord provided by the dealer to ensure safety and EMC compliance Various Factors of Environment vi WPC 765 WPC 765E User s manual Do not insert objects into the openings Do not have liquids seep into the internal areas of the Mini PC unit Having liquids seep in or inserting objects into the unit may result in electric shocks from taking and or short circuiting the internal parts Do not place the mini PC unit in the presence of high moisture areas Do not install the mini PC unit in a wet environment Do not place near unit near heat generating sources Do not place the unit in a location where it will come in contact with fumes or steam Remember to keep the mini PC unit away from the presence of dust If water has flow in or seep in immediately disconnect the open frame unit Then contact a service technician for repairs Ventilation Spacing 1 Do not cover or block the openings on the top and back sides of the display unit Inadequate ventilation may cause overh
2. is dropped or damaged d If smoke or strange odor is flowing out of the operating unit e If the power cord or plug is damaged f When the functions of the unit are dysfunctional When replacement parts are needed for the mini PC unit make sure service technicians use replacement parts specified by the manufacturer or those with the same characteristics and performance as the original parts If WPC 765 WPC 765E User s manual unauthorized parts are used it may result in starting a fire electrical shock and or other dangers ISO 7000 0434 Caution consult ACCOMPANYING DOCUMENTS ISO 7000 1641 Follow operating instructions or Consult instructions for use A lii YO IEC 60417 5009 STAND BY IEC 60417 5031 Direct current a EU wide legislation as implemented in each Member State requires that waste electrical and electronic products carrying the mark left must be disposed of separately from normal household waste This includes monitors and electrical accessories such as signal cables or power cords When you need to dispose of your display products please follow the guidance of your local authority or ask the shop where you purchased the product or if applicable follow any agreements made between yourself The mark on electrical and electronic products only applies to the current European Union Member States WPC 765 WPC 765E User s manual ix When networking w
3. 65 WPC 765E can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the model WPC 765 WPC 765E as recommended below according to the maximum output power of the communications equipment for domestic purposes including domestic establishments Harmonie and those directly connected to the pe public low voltage power supply IEC 61000 3 2 Im network that supplies buildings used 6 WPC 765 WPC 765E User s manual Rated maximum Separation distance according to output power of frequency of transmitter transmitter m W 150 kHzto 80MHzto 800 MHz to 80 MHz 800 MHz 2 5 GHz d 1 2 F d 1 2 F d 2 3 F For transmitters rated at a maximum output power not listed above the recommended separation distanced in meters m can be estimated using the equation applicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE 1 At 80 MHz and 800 MHz the separation distance for the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people Guidance and manufacturer s declaration electromagnetic immunity The model WPC 765 WPC 765E is intended for use in the electromagnetic environment specified below
4. B CD DVD drive please connect USB CD DVD drive turn on computer power keep on pressing F11 key go into BIOS quick boot menu select USB CD ROM WAIT FOR 20 SECONDS then press enter system OS will boot up from USB CD DVD drive directly 12 WPC 765 WPC 765E User s manual Dimension WPC 765 Mount Screw type M4 WPC 765 WPC 765E User s manual 13 WPC 765E Mount Screw type M4 l CJ 2 Le i OF BY YE Quoi gt Se 14 WPC 765 WPC 765E User s manual System View Front View amp I O parts WPC 765 LANx 2 Microphone in RS232 422 485 DVI I RS232 x5 Reset USB x 4 USB 2 0 3 0 DC in Line out WPC 765 WPC 765E User s manual 15 16 Front View amp I O parts WPC 765E WPC 765 WPC 765E User s manual WPC 765 WPC 765E U ser s manua APPENDIX B Scrap Computer Recycling Ifthe computer equipments need the maintenance or are beyond repair we strongly recommended that you should inform us as soon as possible for the suitable solution For the computers that are no longer useful or work well please contact with worldwide distributors for recycling The worldwide distributors show on t
5. IONS sneskred eden 4 Guidance and manufacturer s declaration electromagnetic emissions 6 Guidance and manufacturer s declaration electromagnetic immunity 7 Guidance and manufacturer s declaration electromagnetic immunity 9 MUNIE Len Mann en R let 9 Cleaning Disinfecting 11 Getting Started scene 12 System SEE Ups unes tn Rs s es 12 Dimension Sn Man A E 13 System VIENNE SANS A nn rs 15 Disconnect Devices sans 17 B Scrap Computer Recycling 18 xii WPC 765 WPC 765E User s manual Introduction Product Description The WPC 765 WPC 765E Mini PC are based on Intel 3rd generation Core i processor which can deliver faster graphic with higher CPU performance It accommodates one 2 5 SATA III hard disk drive and up to 8GB DDR3 SODIMM Fanless solution integrated multimedia functions and extensive expansion options make them the perfect platform upon which to build comprehensive lifestyle computing applications The WPC 765 WPC 765E is compact Giga LAN and selectable WLAN network compatible PC with full safety and medical approval and features to control a dedicated system with a wide variety of applications Combining the WPC 765 WPC 765E into your system can achieve both cost saving and efficient improvements Common applications include Surgical Radiology PACS Picture Archiving C
6. The customer or the user of the model WPC 765 WPC 765E should assure that it is used in such an environment Immunity IEC 60601 Compliance Electromagnetic test test level level environment guidance Electrostatic 6 kV 6 kV Floors should be wood discharge contact contact concrete or ceramic tile If ESD floors are covered with IEC y mM synthetic material the relative 61000 4 2 aN alt seal humidity should be at least 30 WPC 765 WPC 765E User s manual 7 Electrical fast transient burst IEC 61000 4 4 Surge IEC 61000 4 5 interruptions and voltage variations on power supply input lines IEC 61000 4 11 2 kV for power supply lines 1 kV for input output lines 1 KV line s to line s 2 kV line s to earth lt 5 UT gt 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles lt 5 UT gt 95 dip in UT for 5 sec 2 kV for power supply lines 1 kV for input output lines 1 kV line s to line s 2 kV line s to earth lt 5 UT gt 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles lt 5 UT gt 95 dip in UT for 5 sec Mains power quality should be that of a typical commercial or hospital environment Mains power quality should be that of a typical commercial or hospital environment Mains powe
7. WPC 765 WPC 765E Mini PC USER S MANUAL P N 205GOOOWPC7650 V1 0 Copyright 2013 All rights reserved All other brand names are registered trademarks of their respective owners The information contained in this document is subject to change without notice Version Change History Date Version Description Remark 2014 01 21 1 0 First release Cosa Huang ii WPC 765 WPC 765E User s manual Acknowledgments Intel 3rd generation Core i and Celeron are registered trademarks of Intel Corporation IBM PC AT PS 2 are trademarks of International Business Machines Corporation Microsoft Windows is a registered trademark of Microsoft Corporation RTL is a trademark of Realtek Semi Conductor Co Ltd C amp T is a trademark of Chips and Technologies Inc UMC is a trademark of United Microelectronics Corporation ITE is a trademark of Integrated Technology Express Inc VIA is a trademark of VIA Technology Inc Award is a registered trademark of Award Software International Inc PS 2 is a trademark of International Business Machines Corporation Intel is a trademark or registered trademark of Intel Corporation Microsoft Windows is a registered trademark of Microsoft Corporation Winbond is a registered trademark of Winbond Electronics Corporation All other product names or trademarks are properties of their respective owners WPC 765
8. WPC 765E User s manual iii FCC Class B This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential environment This equipment generates uses and can radiate radio frequency energy If not installed and used in accordance with this user manual it may cause harmful interference to radio communications Note that even when this equipment is installed and used in accordance with this user manual there is still no guarantee that interference will not occur If this equipment is believed to be causing harmful interference to radio or television reception this can be determined by turning the equipment on and off If interference is occurring the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment to a power outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Warning Any changes or modifications made to the equipment which are not expressly approved by the relevant standards authority could void your authority to operate the equipment To avoid risk
9. eating thus reducing the lifespan of the unit Unless proper ventilation is present do not place unit in an enclosed area such as a built in shelf Keep a minimum distance of 10 cm between the display unit and wall WPC 765 WPC 765E User s manual vil Cleaning the unit 1 Remember to turn off the power source and to unplug the cord from the outlet before cleaning the unit Carefully dismount the unit or bring the unit down from suspension to clean Please use a dry soft cloth to clean the unit Take a dry cloth and wipe the unit dry Remember to avoid having liquids seep into the internal components and areas of the mini PC unit Servicing Repairing Maintenance amp Safety Checks 1 viii If the unit is not functioning properly observe the performance level of the display closely to determine what type of servicing is needed Do not attempt to repair the mini PC unit on your own Disassembling the cover exposes users to high voltages and other dangerous conditions Notify and request a qualified service technician for servicing the unit To avoid risk of electric shock this equipment must only be connected to a supply mains with protective earth If any of the following situations occur turn the power source off and unplug the unit Then contact a qualified service technician a A liquid was spilled on the unit or objects have fallen into the unit b The unit is soaked with liquids c The unit
10. equipment in the patient environment and IEC 60XXX certified equipment outside of the patient environment If in doubt consult the technical services department or your local representative x WPC 765 WPC 765E User s manual Caution DO NOT LEAVE THIS EQUIPMENT IN AN UNCONTROLLED ENVIRONMENT WHERE THE STORAGE TEMPERATURE IS BELOW 20 C 4 F OR ABOVE 60 C 140 F THIS MAY DAMAGE THE EQUIPMENT The user is not to touch SIP SOPs and the patient at the same time The sound pressure level at the operator s position according to IEC 704 1 1982 is no more than 70dB A A Grounding reliability can only be achieved when the equipment is connected to an equivalent receptacle marked Hospital Only or Hospital Grade B Use a power cord that matches the voltage of the power outlet which has been approved and complies with the safety standard of your particular country C Caution This adapter Sinpro MPU101 105 is a forming part of the medical device Contact information 3F No 14 Prosperity Road II Science Based Industrial Park Hsinchu Taiwan 300 R O C TEL 886 3 5780000 E Mail Sales wincomm com tw WPC 765 WPC 765E User s manual xi Table of Contents ACKNOWIedOMENES ES nan lire iii PCG CISS Bis os Re ane iv Safety Instructions sata ia Getieacddniehtealeren de v Introduction css rer 1 Product DESCrIDEIOM Satin nn de 1 Package HSE a e ee 2 FEATURES iltre seere bkg ain e gens 3 SHECHICAT
11. he following website http www wincomm com tw contact aspx Note Follow the national requirement to dispose unit 18 WPC 765 WPC 765E User s manual
12. ith electrical devices the operator is responsible for ensuring that the resulting system meets the requirements set forth by the following standards EN 60601 1 IEC 60601 1 Medical electrical equipment Part 1 General requirements for safety EN 60601 1 1 IEC 60601 1 1 Medical electrical equipment Part 1 1 General requirements for safety Collateral standard Safety requirements for Medical electrical systems EN 60601 1 2 IEC 60601 1 2 Medical electrical equipment Part 1 2 General requirements for safety Collateral standard Electromagnetic compatibility Requirements and tests Accessory equipment connected to SSI the analog and digital interfaces gt 4 must be in compliance with the C US respective nationally harmonized IEC standards i e IEC 60950 for me data processing equipment IEC With Respect To Electric Shock 60065 for video equipment IEC Fire And Mechanical Hazard Only In Accordance With ANSI AAMI ES60601 1 61010 1 for laboratory equipment Can csA c22 2 No 60601 1 and IEC 60601 1 for medical equipment Furthermore all configurations shall comply with the system standard IEC 60601 1 1 Everybody who connects additional equipment to the signal input part or signal output part configures a medical system and is therefore responsible that the system complies with the requirements of the system standard IEC 60601 1 1 The unit is for exclusive interconnection with IEC 60601 1 certified
13. of electric shock this equipment must only be connected to a supply mains with protective earth Do not modify this equipment without authorization of the manufacturer iv WPC 765 WPC 765E User s manual Safety Instructions Intended use The WPC 765 765E is intended to serve as a mini PC which is designed for general purpose for hospital environment It shall not be used for life supporting system Greeting amp Setup Thank you for purchasing the WPC 765 WPC 765E unit We wish that this unit will be durable and reliable in providing your medical application needs Please follow the instructions below to ensure the unit continues to have high performance Unpacking After opening the carton there will be a mini PC unit with an accessory box Examine the contents to see if there are damages to the unit and if all accessories are present Setting up Please read this manual carefully and remember to keep this manual for future reference Safety Instructions amp Cleaning The unit has undergone various tests in order to comply with safety standards Inappropriate use of the open frame unit may be dangerous Please remember to follow the instructions below to insure your safety during the installation and operating process Transporting amp Placement of unit 1 When moving the unit on a cart be very cautious Quick stops excessive forces and uneven surfaces may cause the cart to overturn thus risking the unit to fall
14. ommunication Systems LIS Lab Information Systems and Electronic Medical Record The WPC 765 WPC 765E are definitely your perfect choices WPC 765 WPC 765E User s manual 1 Package list Before you begin installing your Medical Station please make sure that the following items have been shipped e The WPC 765 or WPC 765E Mini PC unit e One DVD containing user manual chipset drivers e Power Adapter x 1 Mf Sinpro type model MPU101 105 e Power cord Hospital grade used US type or other type in UK EU etc 2 WPC 765 WPC 765E User s manual Features Intel 3rd Generation lv y Bridge Core i7 i5 i3 CPU True Fanless design for 0 C 40 C operating temp Medical 60601 1 3rd edition certification Rugged SECC aluminum metal enclosure Rich COM ports for control applications Mini PCl e sockets for WLAN amp other add on expansions 16 GB maximum memory for dual channel DDR3 SODIMM Flexible customization for specific application requests WPC 765 WPC 765E User s manual Specifications Hardware Specifications Support Ivy bridge Intel Core i7 i5 i3 rPGA CPU Socket Type Processor 35W max Support Core i7 3632QM 6M Cache 2 20 GHz Core i5 3210M 3M Cache 2 50 GHz Core i3 3110M 3M Cache 2 40 GHz Intel HM76 PCH BIOS 4Mb AMI Flash BIOS Intel integrated HD Graphics 4000 by Ivy bridge Realtek ALC262 Audio Codec 2 2 watts power Audio amplifier Marvell 88E8071 Giga LAN x 2 T
15. r quality should be that of a typical commercial or hospital environment If the user of the model WPC 765 W PC 765Erequire s continued operation during power mains interruptions it is recommended that the model WPC 765 WPC 765E be powered from an uninterruptible power supply or a battery WPC 765 WPC 765E User s manual Power 3 A m 3 A m Power frequency magnetic frequency fields should be at levels 50 60 Hz characteristic of a typical location in a typical commercial or hospital environment magnetic field IEC 61000 4 8 NOTE UT is the a c mains voltage prior to application of the test level Guidance and manufacturer s declaration electromagnetic immunity The model WPC 765 WPC 765E is intended for use in the electromagnetic environment specified below The customer or the user of the model WPC 765 WPC 765E should assure that it is used in such an environment Immunity Compliance Electromagnetic environment guidance level Portable and mobile RF communications equipment should be used no closer to any part of the model WPC 765 WPC 765E including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Recommended separation distance Conducted RF d 1 2 JF IEC 61000 4 6 d 1 22 P 80 MHz to 800 MHz d 2 8 P 800 MHz to 2 5 GHz Radiated RF IEC 61000 4 3 where Pis the maximum output power rating of the transmitter in wat
16. ser s manual Cleaning Disinfecting Steps 1 Wipe the WPC 765 WPC 765E with a dry clean cloth 2 Prepare agent per manufacturer s instructions or hospital protocol Cautions Do not immerse or rinse the WPC 765 WPC 765E and its peripherals If you accidentally spill liquid on the device disconnect the unit from the power source Contact your Biomed regarding the continued safety of the unit before placing it back in operation Do not spray cleaning agent on the chassis Do not use disinfectants that contain phenol Do not autoclave or clean the WPC 765 WPC 765E or its peripherals with strong aromatic chlorinated ketone ether or Esther solvents sharp tools or abrasives Never immerse electrical connectors in water or other liquids WPC 765 WPC 765E User s manual 11 Getting Started System Set Up The following is a summary of the steps in setting up the system for use 1 You can fix the system to a mounting fixture using the screw holes on the sides of the system 2 Make any required external connections such as the display keyboard and LAN 3 Plug the appropriate end of the power cord into the power connector on the rear of the system and the plug to an electrical outlet 4 Waiting for 3 seconds then press the power switch on the system once to turn on the system power 5 If necessary run the BIOS SETUP programs to configure the system Caution In order to boot up system from US
17. to the ground 2 If the mini PC unit does fall to the ground immediately turn the power off and disconnect cords Then contact a service technician for repairs Continual use of the unit may result cause a fire or electric shock Also do not repair the unit on your own WPC 765 WPC 765E User s manual y Having two or more people transporting the display unit is recommended In addition when installing the unit by suspending it also requires two or more people Before suspending the unit make sure the material used for suspension is sturdy and stable If not properly suspended the display unit may fall and cause serious injury to people standing nearby as well as to the unit itself If you wish to mount the display unit remember to use only the mounting hardware recommended by the manufacturer Electrical and Power Source Related 1 This mini PC unit must operate on a power source as shown on the specification label If you are not sure what type of power supply used in the area consult your dealer or local power supplier The power cords must not be damaged Applied pressure added heat and tugging may damage the power cord The power cord must be routed properly when setup takes place We advise that this aspect measure is to prevent people from stepping on the cords or while the unit is suspended to prevent flying objects from getting tangled with the unit Do not overload the AC outlets or extension cords
18. ts W according to the transmitter manufacturer and dis the recommended separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey should be less than the compliance level in each frequency range Interference may occur in the vicinity of equipment marked with the following symbol gt NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people WPC 765 WPC 765E User s manual 9 Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the model WPC 765 WPC 765E is used exceeds the applicable RF compliance level above the model WPC 765 WPC 765E should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as reorienting or relocating the model WPC 765 WPC 765E b Over the frequency range 150 kHz to 80 MHz field strengths should be less than V m 10 WPC 765 WPC 765E U
19. wo 1066 1333 1600 MHz DDR3 SODIMM socket emory support dual Channel non ECC up to 16GB Serial ATA SATA3 300 MB s transfer rate x 1 WDT Generates system reset 256 segments 0 1 2 255 sec min Storage HDD 2 5 SATA HDD drive bay x 1 Expansion slots PCI E PCI E x 16 expansion slot x 1 Generation 3 0 52 pin card edge type compatible to PCI Express Base specification 2 0 x 1 3 3V loaded 0 75A 0 25A 1A 1 5V loaded 0 375A Mini PCIe External 1 0 USB 2 0 x 2 USB 3 0 x 2 RS232 x 5 RS232 RS422 RS485 x 1 RJ 45 x 2 Gigabit Ethernet oe phone jack connector 2 line out and 4 WPC 765 WPC 765E User s manual DVI D x 1 or DVI D x1 CRT x1 option via Y output cable Power Adapter Input Voltage AC 100 240 V 1 25 0 5A 47 63 Hz Output Voltage DC 12V 8 33A MTBF 100 000 hrs operation at 25 C Mechanical Specifications i Aluminum heatsink and SECC with black Architecture coating Mounting Holder Bracket mounting mechanism WPC 765 294 6 188 61 mm Dimension WxHxD WPC 765E 294 6 188 96 2 mm WPC 765 3kg w o power adapter Net Weight WPC 765E 3 8kg w o power adapter Packing Filler Environmental Specifications Operating 0 C to 40 C 32 F 104 F Temperature Storage Transportation 20 C to 60 C 4 F 140 F Operating 10 to 90 40 C non condensing Storage Transportation 10 to 90 non condensing Operating 15g 0 53 o
20. z 11 ms half sine wave Vibration Non operating 50g 1 76 oz 11 ms half sine wave Humidity Operating 5 17 Hz Amplitude 0 117 500HZz Acceleration 1 0G Non operating 10 55Hz 0 15g 55 500Hz 2 0g Operational up to 3000 m 9842 feet Altitudes Shipping up to 12192 m 40000 feet WPC 765 WPC 765E User s manual 5 700 1060 hPa Operation Pressure 186 1060 hPa Storage 186 1060 hPa Transportation Guidance and manufacturer s declaration electromagnetic emissions The model WPC 765 WPC 765E is intended for use in the electromagnetic environment specified below The customer or the user of the model WPC 765 WPC 765E should assure that it is used in such an environment Compliance Electromagnetic environment guidance RF emissions The model WPC 765 WPC 765E CISPR 11 uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment The model WPC 765 WPC 765E is suitable for use in all establishments RF emissions CISPR 11 Voltage fluctuations flicker emissions IEC 61000 3 3 Recommended separation distances between portable and mobile RF communications equipment and the model WPC 765 WPC 765E The model WPC 765 WPC 765E is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the model WPC 7
Download Pdf Manuals
Related Search
WPC 765/WPC 765E
Related Contents
25/06/2013 : 2.262 Service Manual - E Assembly Montaje K 2.21 OneTouch ® Diabetes Management Software Version Philips AZ9345 User's Manual A Quick Guide to WRX Tuning with the UTEC CB Predictor™1.6 Copyright © All rights reserved.
Failed to retrieve file