Accutrend® Plus - Quick Reference Guide
Contents
1. 33 3mmol L Cholesterol lt 3 88 mmol L gt 776mmol L When measuring tests on several people clean and disinfect the instrument with an alcohol wipe before each measurement Triglycerides lt 0 8mmol L gt 6 86mmol L Lactate lt 0 8mmol L gt 21 7mmol L blood cobas Life needs answers
2. Accutrend Plus Quick Reference Guide What you need e Accutrend Plus e Test strips amp related code strip e Lancing device e g Safe I Pro Plus e Alcohol wipe e Gloves e Tissue Place the instrument on a level vibration free surface and switch on by pressing the On Off button Check the display If no code has been stored in the in strument the display will look like this a code ee a2 a lA codenr gt 3g a Otherwise the last stored code will be displayed amp the screen will look like this fb 48 2L The meter will store the data of one code strip per test parameter To check other tests amp code numbers in the meter press the set key Lance the finger and milk site to produce a drop of blood Wipe off the first drop Milk the site again to form a large hanging drop of blood Note Lift the chamber flap and remove the test strip leave the flap open Apply the hanging blood directly to the reaction pad Do not touch the pad The application area must be completely covered with blood Insert the test strip back into the instrument A plausibility check must be performed for all glucose measurements See page 80 of the user s manual for instructions Protection against infections There is a potential risk of infection Medical staff and other persons using the Accutrend Plus instrument to perform measurements for more than one patient m
3. ust be aware that any object coming into contact with human blood is a potential source of infection If your test code is not displayed it will be necessary to insert the code strip for the test strip lot you wish to use Hold the code strip behind the black bar and with the chamber flap closed insert the code strip as far as it will go and remove it immediately Do this firmly with consistent speed If successful you will hear 1 beep If unsuccessful the screen will look like this A 8 S HAN Lift the chamber flap to clear the message or wait a few seconds and try again Close the chamber flap This starts the measurement amp countdown Cholesterol The meter will beep 4 secs out from displaying the result For Assistance Phone T hline 0800 363622 Remove a test strip from the container and close the container immediately Check it s appearance for discolouration Do not used if discoloured Choose the lancing site pref middle finger outer side and clean with alcohol wipe Dry with tissue Insert the test strip firmly with consistent speed as far as it will go If successful you will hear 2 beeps A flashing arrow indicates that the meter is now ready for you to open the chamber flap to apply the drop of blood At this stage keep it closed You have approx 2 minutes before the meter will auto off Interpretation of Hi or Lo results ee a tl lt 1 1 mmol L gt
Download Pdf Manuals
Related Search
Related Contents
télécharger ici Ring Modulator issue 3 Builder`s Guide La mise en place d`une institution représentative du IPdio Tune N° 74 - Croissy-sur MANUAL DE USUARIO - Componentes para automatismos J 1 Tout commence avec Dieu User Manual for the LMD Martian Atmospheric General Circulation USER INSTRUCTIONS - Flowserve Corporation Copyright © All rights reserved.
Failed to retrieve file