Home
Sealevel Systems REL-32.PCI Manual
Contents
1. eeeeee eene nenne nen aee aea aea aea aea aee aee aea aee aee eee aea eaae 3 PHYSICAL hehehe sese sese 5 PROGRAMMING THE REL 32 PCL ccccccccocscssssssssssssscscsssccsscccscccscccscccscccscccscccscesscccscssees 6 PROGRAMMING FOR 5 0 6 PROGRAMMING FOR LINUX csceccssccccsscccsecccsccccssceuseccessceauecceucecsesseauecesssecsesceascceasseeauecceuceeae 6 DIGITAL VO INTERFACE 6 OUTPUT PORTS REED RELAY miee Fe DR EURO EDAM 6 CONNECTOR AND JUMPER PIN 2 2 020000 0000000000000 EELA ERRENA 6 JUMPER SETUP OPTIONS 0 00000 0 000000000000 7 OUTPUT PORTS REED RELAY PIN ASSIGNMENTS 8 POWER AND GROUND PIN ASSIGNMENTS 2 8 DB 78 FEMALE 55 00000 000000100 10 DIRECT HARDWARE CONTROL 0 0 000000000 010000000 11 READING THE OUTPUTS 2 0 bade uu 11 WRI
2. 4 rtisan tisan Technology Group is your source for quality Femoog Ge new and certified used pre owned equipment FAST SHIPPING AND SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT DELIVERY Experienced engineers and technicians on staff Sell your excess underutilized and idle used equipment TENS OF THOUSANDS OF at our full service in house repair center We also offer credit for buy backs and trade ins IN STOCK ITEMS www artisantg com WeBuyEquipment EQUIPMENT DEMOS HUNDREDS OF Instra REMOTE INSPECTION LOOKING FOR MORE INFORMATION MANUFACTURERS Remotely inspect equipment before purchasing with Visit us on the web at www artisantg com 7 for more our interactive website at www instraview com 7 information on price quotations drivers technical LEASING MONTHLY specifications manuals and documentation RENTALS ITAR CERTIFIED Contact us 888 88 SOURCE sales artisantg com www artisantg com REL 32 PCI User Manual Part Number 8007 SYSTEMS INCORPORATED www sealevel com PO Box 830 Liberty SC 29657 864 843 4343 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Table of Contents INTRODUCTION E c 1 OTHER SEALEVEL PCI DIGITAL I O PRODUCTS eese 000000070 1 BEFORE YOU GET STARTED 2 WHAT S INCLUDE ttum em Ie RUM EI MU 2 OPTIONAL esten ede a I e ene MI NI 2 SOFTWARE INSTALLATION
3. Inc 3 32 User Manual Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Linux Installation Note You MUST have root privileges to install the software and drivers 1 Login as root 2 Mount the CDROM by typing mount t iso4860 dev hdc cdrom Note Your cdrom may not be dev hdc it could be dev hda dev hdb dev hdd or if you have a SCSI drive dev sda dev sdb dev sdc etc You may mount the CDROM to any location the cdrom is just a common example 3 Next change to the directory where you mounted the CDROM Ex cd cdrom software SealO Other linux Note The syntax is case sensitive 4 Copy seaio tar gz to your home directory by typing cp seaio tar gz 5 Change to your home directory by typing cd 6 Unmount the drive and then Unzip and Untar the drivers and software by typing umount cdrom tar xvzf seaio tar gz 7 Change to the SeaIO directory by typing cd SealO 8 Now compile and prepare the drivers for use make install 9 With the system off and unplugged install your SealO PCI card 10 Plug system back in and boot Linux Login as root 11 Load the driver by typing SealO load The driver has enabled the card and is ready to use and you now have the option to run a test utility on it Skip to section Using the test software if you wish to do so at this time To set up Linux to automatically load the driver refer to a Linux manua
4. 3 relay 5 K21 is tied to the common Port 2 The common is tied to 5 volts The B side of port 2 relay 4 K12 is tied to the common Port 1 The common is tied to 12 volts The A side of port 1 relay 1 K1 is tied to the common The A side of port 1 relay 8 K8 is tied to the common Port 4 A GND com SEU aR 5V 12V 12345678 Port 3 Ath com 5V 12V 12345678 Port 2 A BHEEESEER GND sv B 1am 11mm 12V 12345678 Port 1 n GND E EEEIS EB 5V pssEEEEHNBN 12V 12345678 Sealevel Systems Inc 7 RE 32 PA User Manual Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Output Ports Reed Relay Pin Assignments Via standard 6 cable DB 78 Male to dual DB 37 Male connectors Part Number CA172 The DB 37 connectors are labeled Ports 1 2 and Port 3 4 Port 1 Port 2 Relay A Side Relay B Side Relay A Side Relay B Side Relay Port 1 A Pin Port 1 B Pin Relay Port 2 A Pin Port 2 B Pin 1 2 1 20 9 1 10 1 28 2 2 3 2 21 0 2 11 2 29 3 4 3 22 Kil 3 12 3 30 K4 4 5 4 23 2 4 13 4 31 5 5 6 5 24 5 14 5 32 K6 6 7 6 25 4 6 15 6 33 K7 7 8 7 26 5 7 16 7 34 K8 8 9 8 27 K16 8 17
5. Inc 15 32 User Manual Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Appendix Silk Screen 8007 4 20 i 6 60 E n n X E oo 20 D n zm zo mm mm aon mm mm v 3 875 Sealevel Systems Inc 16 32 User Manual Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Appendix Compliance Notices Federal Communications Commission Statement FCC This equipment has been tested and found to comply with the limits for Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in such case the user will be required to correct the interference at the users expense EMC Directive Statement Products bearing the CE Label fulfill the requirements of the EMC direc
6. PCI provides four parallel Reed Relay output ports The ports are organized as 1 2 and 3 4 Output Ports Reed Relay Reed relays provide very high quality long life low power dry contact switch closures Reed relays are not suited for high current applications and can be destroyed by capacitive or inductive load switching The relays are normally open and close when energized Connector and Jumper Pin Out Each relay has two sides an A side and B side Each side is connected to two places the cable and the jumpers on the top of the board The tables on the following pages provide the pin outs for the two DB 37 cable ends and the onboard jumpers Sealevel Systems Inc 6 32 User Manual Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Jumper Setup Options The common on each port may be tied to ground 5 or 12 volts Either side of each relay may then be tied to the common The 8007 is shipped with all of the jumpers necessary for all possible configurations The jumpers are parked on the B side and are inactive until configured by the user An example configuration is shown below Port 4 The common is tied to ground GND The A side of port 4 relay 3 K27 is tied to the common The B side of port 4 relay 6 K30 is tied to the common Port 3 The common is tied to ground GND The A side of port 3 relay 2 K18 is tied to the common The A side of port
7. 64 843 4343 Our technical support is free and available from 8 00AM 5PM Eastern Time Monday through Friday For email support contact mailto support sealevel com Sealevel Systems Inc 14 32 User Manual Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Appendix B How To Get Assistance Begin by reading through the Trouble Shooting Guide in Appendix A If assistance is still needed please see below When calling for technical assistance please have your user manual and current adapter settings If possible please have the adapter installed in a computer ready to run diagnostics Sealevel Systems provides an FAQ section on its web site Please refer to this to answer many common questions This section can be found at http www sealevel com fag asp Sealevel Systems maintains a Home page on the Internet Our home page address is http www sealevel com The latest software updates and newest manuals are available via our FTP site that can be accessed from our home page Technical support is available Monday to Friday from 8 00 a m to 5 00 p m eastern time Technical support can be reached at 864 843 4343 RETURN AUTHORIZATION MUST BE OBTAINED FROM SEALEVEL SYSTEMS BEFORE RETURNED MERCHANDISE WILL BE ACCEPTED AUTHORIZATION CAN BE OBTAINED BY CALLING SEALEVEL SYSTEMS AND REQUESTING A RETURN MERCHANDISE AUTHORIZATION RMA NUMBER Sealevel Systems
8. 8 35 Port 3 Port 4 Relay A Side Relay B Side Relay A Side Relay B Side Relay Port 3 A Pin Port 3 B Pin Relay Port 4 A Pin Port 4 B Pin K17 1 2 1 20 25 1 10 1 28 8 2 3 2 21 K26 2 11 2 29 19 3 4 3 22 K27 3 12 3 30 K20 4 5 4 23 K28 4 13 4 31 K21 5 6 5 24 K29 5 14 5 32 22 6 7 6 25 K30 6 15 6 33 23 7 8 7 26 7 16 7 34 24 8 9 8 27 8 17 8 35 Power and Ground Pin Assignments Via standard 6 cable DB 78 Male to dual DB 37 Male connectors Part Number 172 18 36 37 12 Volts Sealevel Systems Inc 8 32 User Manual Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Optional 37 Female Pin Assignment In order to maintain compatibility with the existing ISA interface adapter Sealevel Item 3098 an optional 6 cable is offered with DB 78 Male to dual DB 37 Female connectors Part Number CA173 The DB 37 connectors are labeled Side A and Side B Side A Side B Pin Function Jumper Pin Function Jumper 1 Ground N A 1 Ground N A 2 Relay 2A PORT 1 A2 2 Relay 2B PORT 1 B2 3 Relay 4A PORT 1 A4 3 Relay 4B PORT 1 B4 4 Relay 6A PORT 1 A6 4 Relay 6B PORT 1 B6 5 Relay 8A PORT 1 8 5 Relay 8B PORT 1 B8 6 Relay 10A PORT 2 A2 6 Relay 10B PORT 2 B2 7 Relay 12A
9. B78M to dual DB37M Cable m Sealevel Seal O Software CD Optional Items Depending upon your application you are likely to find one or more of the following items useful for interfacing the REL 32 PCI to real world signals All items can be purchased from our website http www sealevel com or by calling 864 843 4343 m DB 37 Male to DB 37 Female 6 Cable Part Number CA112 This cable extends the DB 37 connector on the CA172 cable additional six feet and is pinned one to one DB 37 Male Female Terminal Block Part Number 02 Break out serial and digital connectors to 37 screw terminals for easy field connection The 2 terminal block is designed with both DB 37 male and female connectors therefore it can be used with any DB 37 board regardless of the board s port gender m Cable and Terminal Block Kit Part Number KT101 For convenient and easier ordering the KT101 includes the 2 terminal block and 112 cable in a single kit Sealevel Systems Inc 2 32 User Manual Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Software Installation Windows 98 2000 XP Installation Do not install the Adapter in the machine until the software has been fully installed 1 2 3 Start Windows Insert the Sealevel Systems CD in to your CD drive If Auto Start is enabled for this drive the softwa
10. C 70 m Storage 509 105 C Power Requirements m 5VDC 560 mA Physical Dimensions m PCBLength 6 60 16 764 cm Height 4 20 10 668 cm including Gold fingers Manufacturing All Sealevel Systems Printed Circuit boards are built to UL 94V0 rating and are 100 electrically tested These printed circuit boards are solder mask over bare copper or solder mask over tin nickel Sealevel Systems Inc 12 32 User Manual Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Example Circuits Output Circuit Output Common Output Port Bit Sealevel Systems Inc 13 32 User Manual Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Appendix Troubleshooting Following these simple steps can eliminate most common problems 1 Install software first After installing the software then proceed to adding the hardware This places the required installation files in the correct locations 2 Read this manual thoroughly before attempting to install the adapter in your system 3 Use Device Manager under Windows to verify proper installation 4 Use the SealO Control Panel applet or the Device Manager s property page for card identification and configuration 5 If these steps do not solve your problem please call Sealevel Systems Technical Support 8
11. E 32 PA User Manual DB 78 Female Pin Assignment This table shows the pin assignments via the card edge connector Power and Ground Pin Assignments Via DB 78 Female card edge connector 18 36 37 55 73 74 19 56 12 Volts Sealevel Systems Inc 10 RH 32 PQ User Manual Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Port 1 Port 2 Relay A Side Relay B Side Relay A Side Relay B Side Relay Port 1 A Pin Port 1 B Pin Relay Port2 A Pin Port 2 B Pin 1 2 1 20 9 1 10 1 28 2 2 3 2 21 0 2 11 2 29 K3 3 4 3 22 Kil 3 12 3 30 K4 4 5 4 23 2 4 13 4 31 K5 5 6 5 24 5 14 5 32 K6 6 7 6 25 4 6 15 6 33 K7 7 8 7 26 15 7 16 7 34 K8 8 9 8 27 6 8 17 8 35 Port 3 Port 4 Relay A Side Relay B Side Relay A Side Relay B Side Relay Port3 A Pin Port 3 B Pin Relay Port4 A Pin Port 4 B Pin 1 39 1 57 25 1 47 1 65 K18 2 40 2 58 K26 2 48 2 66 K19 3 41 3 59 K27 3 49 3 67 K20 4 42 4 60 K28 4 50 4 68 K21 5 43 5 61 K29 5 51 5 69 K22 6 44 6 62 K30 6 52 6 70 K23 7 45 7 63 7 53 7 71 24 8 46 8 64 K32 8 54 8 72 Direct Hardware Control In systems where the users program has direct access to the hardware DOS the table below gives the mapping and functions that the R
12. EL 32 PCI provides Function Port Address Hex Port Type Available 1 0 Relay 1 Relay 8 2 Base 1 Relay 9 Relay 16 RW 3 Base 2 Relay 17 Relay 24 Relay 25 Relay 32 R W Read or Write Reading the Outputs The relay ports return the ones complement of the value that is currently being used to drive the relays When using the API the value is returned not the complement of the value Writing the Outputs The relays on a standard 8007 are normally open To close a relay a one must be written to the appropriate bit Register Description Address Mode 07 06 05 4 D2 Sealevel Systems Inc 11 32 User Manual Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Electrical Characteristics Features Specifications 32 SPST Reed relays Two DB 37 Male connectors CA172 cable Highly reliable 10 VA DIP reed relays utilized m Multiple adapters can reside in same computer PCI 2 1 Bus compliant Output Relays Contact Max Power Rating 10 W m Contact Voltage Maximum 100 VDC VAC m Contact Current Maximum A AC DC RMS Contact Resistance Initial 150 Rated Life Low Load 200 Million Closures e Maximum Load 100 Million Closures m Contact Speed e Operate 5 mS e Release 5 mS e Bounce 5 mS m Maximum Operating Speed 600 Hz Temperature Range m Operating 0
13. PORT 2 A4 7 Relay 12B PORT 2 B4 8 Relay 14A PORT 2 A6 8 Relay 14B PORT 2 B6 9 Relay 16A PORT 2 8 9 Relay 16B PORT 2 B8 10 Relay 18A PORT 3 A2 10 Relay 18B PORT 3 B2 11 Relay 20A PORT 3 A4 11 Relay 20B PORT 3 B4 12 Relay 22A PORT 3 A6 12 Relay 22B PORT 3 B6 13 Relay 24A PORT 3 8 13 Relay 24B PORT 3 B8 14 Relay 26A PORT 4 A2 14 Relay 26B PORT 4 B2 15 Relay 28A PORT 4 A4 15 Relay 28B PORT 4 B4 16 Relay 30A PORT 4 A6 16 Relay 30B PORT 4 B6 17 Relay 32A PORT 4 8 17 Relay 32B PORT 4 B8 18 12 V N A 18 12 V N A 19 5V N A 19 5V N A 20 Relay 1A PORT 1 A1 20 Relay 1B PORT 1 B1 21 Relay 3A PORT 1 A3 21 Relay 3B PORT 1 B3 22 Relay 5A PORT 1 A5 22 Relay 5B PORT 1 B5 23 Relay 7A PORT 1 A7 23 Relay 7B PORT 1 B7 24 Relay 9A PORT 2 A1 24 Relay 9B PORT 2 B1 25 Relay 11A PORT 2 25 Relay 11B PORT 2 B3 26 Relay 13A PORT 2 A5 26 Relay 13B PORT 2 B5 27 Relay 15A PORT 2 A7 27 Relay 15B PORT 2 B7 28 Relay 17A PORT 3 A1 28 Relay 17B PORT 3 B1 29 Relay 19A PORT 3 29 Relay 19B PORT 3 B3 30 Relay 21A PORT 3 A5 30 Relay 21B PORT 3 B5 31 Relay 23A PORT 3 A7 31 Relay 23B PORT 3 B7 32 Relay 25A PORT 4 A1 32 Relay 25B PORT 4 B1 33 Relay 27A PORT 4 33 Relay 27B PORT 4 B3 34 Relay 29A PORT 4 A5 34 Relay 29B PORT 4 B5 35 Relay 31A PORT 4 A7 35 Relay 31B PORT 4 B7 36 Ground N A 36 Ground N A 37 Ground N A 37 Ground N A Sealevel Systems Inc Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com R
14. TING THE OUTPUTS 11 REGISTER DESCRIPTION 2 11 ELECTRICAL 1 1 555 12 LEEATURES 2 uer ran M i e E 12 SPECIEICATIONS tret tue eter 12 EXAMPLE CIRCUITS esesvsssscccsiscssccssscsescsescsssesesssesesesesosssosssssssoessecesoessoscsdsesscssosesesssseossssssosssess 13 APPENDIX A TROUBLESHOOTING 14 APPENDIX HOW GET ASSISTANCE 15 APPENDIX SILK SCREEN 8007 PCB ccccscccscccscscscscscscscccssccscscscccccccccccscceseseees 16 APPENDIX COMPLIANCE NOTICES 17 FEDERAL COMMUNICATIONS COMMISSION STATEMENT 2 0 000000000002 17 WARRANTY icssisceccscdccsccsocscccesssccoccsscccoscsscesoccsoccovccds ccesccesccoccs scseccsosccoceds scosecebesvecss ssecesoosocesoocs 18 Sealevel Systems Inc 32 User Manual SL9082 Revision 7 2006 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Introduction The REL 32 PCI provides 32 reed relays that can switch power data or other electronic signals for control applications The outputs provide high quality long life low current 10 Watt maximum dry contact switch closures Reed relays are well suited for low current applications The relays a
15. ed and manufactured at its Liberty South Carolina facility allowing direct control over product development production burn in and testing Sealevel Systems Inc hereafter Sealevel warrants that the Product shall conform to and perform in accordance with published technical specifications and shall be free of defects in materials and workmanship for life In the event of failure Sealevel will repair or replace the product at Sealevel s sole discretion Failures resulting from misapplication or misuse of the Product failure to adhere to any specifications or instructions or failure resulting from neglect or abuse are not covered under this warranty Warranty service is obtained by delivering the Product to Sealevel and providing proof of purchase Return authorization must be obtained from Sealevel Systems before returned merchandise will be accepted Authorization is obtained by calling Sealevel Systems and requesting a Return Merchandise Authorization RMA number The Customer agrees to insure the Product or assume the risk of loss or damage in transit to prepay shipping charges to Sealevel and to use the original shipping container or equivalent Warranty is valid only for original purchaser and is not transferable Sealevel Systems assumes no liability for any damages lost profits lost savings or any other incidental or consequential damage resulting from the use misuse of or inability to use this product Sealevel Systems wi
16. l concerning your specific distribution for help Sealevel Systems Inc 4 2 User Manual Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Physical Installation The adapter can be installed in any 5V PCI expansion slot Do not install the Adapter in the machine until the software has been fully installed 1 Turn off PC power Disconnect the power cord 2 Remove the PC case cover 3 Locate an available 5V PCI slot and remove the blank metal slot cover 4 Gently insert the PCI adapter into the slot Make sure that the adapter is seated properly 5 After the adapter has been installed the cables should be routed thru the opening in the bracket This bracket also features a strain relief function that should be used to prevent un expected cable removal 6 Replace the screw you removed for the blank and use it to secure the adapter into the slot This is required to ensure FCC Part 15 compliance 7 Replace the cover 8 Connect the power cord The REL 32 PCI is now ready for use Sealevel Systems Inc 5 32 User Manual Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Programming the REL 32 Sealevel s Seal O software is provided to assist in the development of reliable applications for the Sealevel Systems family of digital I O adapters Included on the Seal O CD are drive
17. ll not be liable for any claim made by any other related party This warranty applies to Sealevel manufactured Product Product purchased through Sealevel but manufactured by a third party will retain the original manufacturer s warranty Sealevel Systems Incorporated 2779 Greenville Highway P O Box 830 Liberty SC 24857 USA 864 843 4343 FAX 864 843 3067 www sealevel com email support sealevel com Technical Support is available Monday Friday from 8 a m to 5 p m Eastern time Trademarks Sealevel Systems Incorporated acknowledges that all trademarks referenced in this manual are the service mark trademark or registered trademark of the respective company Sealevel Systems Inc 18 32 User Manual Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com 4 rtisan tisan Technology Group is your source for quality Femoog Ge new and certified used pre owned equipment FAST SHIPPING AND SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT DELIVERY Experienced engineers and technicians on staff Sell your excess underutilized and idle used equipment TENS OF THOUSANDS OF at our full service in house repair center We also offer credit for buy backs and trade ins IN STOCK ITEMS www artisantg com WeBuyEquipment EQUIPMENT DEMOS HUNDREDS OF Instra REMOTE INSPECTION LOOKING FOR MORE INFORMATION MANUFACTURERS Remotely inspect equipment before purchasi
18. ng with Visit us on the web at www artisantg com 7 for more our interactive website at www instraview com 7 information on price quotations drivers technical LEASING MONTHLY specifications manuals and documentation RENTALS ITAR CERTIFIED Contact us 888 88 SOURCE sales artisantg com www artisantg com
19. r functions for use in accessing the I O as well as helpful samples and utilities Programming for Windows The Seal O API Application Programmer Interface provides a variety of useful high level function calls implemented in a Windows dynamic link library DLL The API is defined in the help file Start Programs SealO SealO Help under Application Programmers Interface This help file also includes detailed information dealing with installation removal of the software and information about latency logic states and device configuration For C language programmers we recommend using the API to access the REL 32 PCI If you are programming in Visual Basic using the ActiveX control included with Seal O is advised Samples and Utilities A variety of sample programs and utilities both executable and source code are included with Seal O Further documentation on these samples can be found by selecting Start Programs SealO Sample Application Description Information about where the files are physically stored on your disk is also included in this same file Programming for Linux Seal O for Linux consists of two major parts a kernel module and a library The kernel module is a simple IO pass through device allowing the library to handle the more sophisticated functions provided to Seal O users It is provided in a tarball format and can easily be compiled and included in the kernel build Digital 1 Interface The REL 32
20. re normally open and will close when energized The REL 32 PCI is PCI 2 1 bus compliant REL 32 PCI is designed to be used with a variety of Operating Systems including Windows 98 NT ME 2000 XP Linux and DOS The 5 API Application Programmer Interface included on CD with the REL 32 PCI provides a variety of useful high level function calls implemented as a Windows dynamic link library DLL and as a Linux kernel module and library In addition to the API Seal O includes sample code and utilities to simplify software development Other Sealevel PCI Digital 1 O Products PIO 24 PCI P N 8008 24 TTL Inputs Outputs PIO 32 PCI P N 8010 32 TTL Inputs Outputs PIO 48 PCI P N 8005 48 TTL Inputs Outputs PIO 96 PCI P N 8009 96 TTL Inputs Outputs DIO 16 PCI P N 8002 8 Reed Relay Outputs 8 Opto isolated Inputs REL 16 PCI P N 8003 16 Reed Relay Outputs DIO 32 PCI P N 8004 16 Reed Relay Outputs 16 Opto isolated Inputs ISO 16 PCI P N 8006 16 Opto isolated Inputs PLC 16 PCI P N 8011 8 Form C Relay Outputs 8 Opto isolated Inputs OSealevlSystems Inc IL RH 32PQUserManud Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Before You Get Started What s Included The REL 32 PCI is shipped with the following items If any of these items is missing or damaged please contact Sealevel for replacement m REL 32 PCI Adapter m CA172 6 D
21. re will automatically launch Otherwise point your browser to the Index htm on the root directory of the CD Select Install Software Select the Part Number for your adapter from the listing Select Windows 98 ME NT 2000 XP setup file will automatically detect the operating environment and install the proper components Next depending on your browser select the Run this program from its current location or option Follow the information presented on the screens that follow A screen may appear with the declaration The publisher cannot be determined due to the problems below Authenticode signature not found Please select the Yes button and proceed with the installation This declaration simply means that the Operating System is not aware of the driver being loaded It will not cause any harm to your system During setup the user may specify installation directories and other preferred configurations This program also adds entries to the system registry that are necessary for specifying the operating parameters for each driver An uninstall option is also included to remove all registry INI file entries from the system Windows NT Card Installation After accomplishing the above steps bring up the Control Panel and double click on the SeaIO Devices icon To install a new card click Add Port Repeat this procedure for as many 5 cards as you wish to install Sealevel Systems
22. tive 89 336 EEC and of the low voltage directive 73 23 EEC issued by the European Commission To obey these directives the following European standards must be met EN55022 Class A Limits and methods of measurement of radio interference characteristics of information technology equipment EN55024 Information technology equipment Immunity characteristics Limits and methods of measurement EN60950 IEC950 Safety of information technology equipment including electrical business equipment Warning This is a Class A Product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures to prevent or correct the interference Always use cabling provided with this product if possible If no cable is provided or if an alternate cable is required use high quality shielded cabling to maintain compliance with FCC EMC directives Sealevel Systems Inc 17 32 User Manual Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Warranty Sealevel s commitment to providing the best I O solutions is reflected in the Lifetime Warranty that is standard on all Sealevel manufactured products We are able to 6 offer this warranty due to our control of manufacturing quality and the historically high reliability of our products in the field Sealevel products are design
Download Pdf Manuals
Related Search
Related Contents
Samsung ST-524J Manual de Usuario Bulletin de droit nucléaire n° 91, Volume 2013/1 User manual - Check 取扱説明書 Philips BTD7170 Friedrich CP05C10 User's Manual KEW 5410 - 計測器ワールド(日本電計株式会社) Tout ce que vous avez toujours voulu savoir sur le DRC Bedienungsanleitung Copyright © All rights reserved.
Failed to retrieve file