1. Reference channel 1341 2504 div 2504 div 250A div _ Time base J 10ms div Window position lt Reference channel 2242 4 28 2005 07 58 10 0 00 0 00 4 28 2005 07 58 12 0 00 0 00 4 28 2005 07 58 13 108 73 5164 22 4 4 28 2005 07 58 15 234 97 17272 46 4 28 2005 07 58 16 230 48 17286 48 4 28 2005 07 58 17 230 16 17257 27 4 28 2005 07 58 18 230 05 17304 57 4 28 2005 07 58 20 230 01 18088 88 4 28 2005 07 58 21 230 01 18389 40 4 28 2005 07 58 22 229 96 18398 59 00 V 0 4 som n7 ca 92 27 y Ready Eneray Net SpA Display of the measurements and graphs is broken down as follows There is a main window organised in cards with the instrument s configuration parameters and the settings of the measuring campaign The first card called Timelines displays the recording start and end date and time together with the relevant data acquisition time frequency time This time may take on values from a minimum of 0 to a maximum of 60 minutes 3600 seconds A campaign with a frequency time of 0 is characterised by a continuous succession of data structured in records each of which includes 60 periods of the measured signals In the case of a campaign having a frequency higher than 0 the single records again including 60 periods are saved with the set freque
2. a et EC EB ra Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 46 of 46 Vizzano 44 40044 Pontecchio Marconi Italy a Tel 39 051 6782006 39 051 845544 2 http www elcontrol energy net ener Y n el sales elcontrol energy net 6 System requirements PC compatible with 600MHz or higher processor Microsoft Windows 9x Se Me NT 4 0 2000 or XP 128 MB of RAM memory 512 recommended SVGA with 256 colours 1024x768 or higher resolution 512 MB of free hard disk space including program installation and the free space necessary for storing a minimum number of measuring campaigns CD DVD ROM drive CF reader external internal or PCMCIA e Pointing system or mouse Note all of the names are registered trademarks of the respective manufacturers Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 47 of 47
3. xti Ek Exi ERE NER EXER Paket dax ad Rabat ibi c ERR aac 17 SEE MEE coo gite tc ETE 18 3 1 5 2 Setting the number of tracks and the parameter associated with 18 3 1 5 3 Indicators of the current record and random record search 20 3 1 6 Grid with rms measurements in Excel style 21 3 1 6 1 Making a graph of a Set of 21 3 1 6 2 Exporting a set of measurements 22 ou _ _____________________ 22 3 1 8 Exporting the measurements a 23 3 2 TRANSIENTS CAMPAIGN e ME ule dU Sw du ad 24 3 2 1 VIO Mic 26 3 2 2 Ihe 26 3 2 3 voltage and current 26 3 2 4 with rms measurements in Excel 26 3 2 5 The transients o RETE 26 3 3 EIN501 60 CAMPAIGN m 27 3 3 1 EN50160 conformity frequency changes and voltage 28 3 3 2 EN50160 conformity harmonic voltage 29 33 3 _ ____ __ __ _
4. 112 ose ooo 5 18 2005 23 46 07 231 30 093 35438 46 0 36 oo 5 18 2005 23 46 08 231 33 093 TE 353 9 35 os oo 00 5 18 2005 23 46 09 231 32 0939 35388 34 e jos 5 18 2005 23 46 11 231 30 51 03 0 939 35411 00 5000 ooo uo 5118 2005 23 46 12 231 33 50 57 0 940 35374 56 50 00 118 038 000 ooo 511812005 23 46 13 231 31 51 03 0 939 ESSEEN 35407 94 5000 119 oss 5 18 2005 23 46 14 196 44 44 47 1 000 26207 03 60 54 120 0 00 oo 5 18 2005 23 46 17 131 79 100 veo B 83 12 120 5 18 2005 23 46 18 230 69 50 73 0 939 TH 35105 29 5000 121 00 0 00 5 18 2005 23 46 20 61 48 14 24 1 000 E 2524 55 250 00 121 039 O00 0 00 5118 2005 23 46 21 327 45 8002 1000 e poma oum 5 18 2005 23 46 22 317 43 o5 ES 4767273 49 99 i122 000 TUSCE TATE iuc 5018 2005 23 46 25 231 33 50 95 0 941 IN 1 50 00 124 040 000 0 00 5 18 2005 23 46 26 231 33 50 94 0941 35352 46 5000 126 ooo ES 5 18 2005 23 46 28 231 29 50 94 0 941 4 5000 128 osi ooo 11 3 1 6 1 Making a gr
5. 30 3 34 30 31 4 CUSTOMISING THE GRAPH 32 5 PRINTING DOCUMENT SS 33 5 1 INFORMATION ABOUT THE MEASURING CAMPAIGN 34 5 2 GRID WITH RMS MEASUREMENTS IN EXCEL 35 5 3 THE HARMONIC 36 5 4 THE VOLTAGE AND CURRENT 37 5 5 THE TIME TREND OF THE RMS MEASUREMENTS IH eene enne nnn i nna sn sensn se sensn snas nsns nnns 38 5 6 THE VECTOR METER EENKEER 39 5 7 THE TRANSIENTS G 40 5 8 THE VOLTAGE AND CURRENT WAVEFORMS 41 5 9 EN50160 CONFORMITY FREQUENCY CHANGES AND VOLTAGE 42 Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice of 3 Vizzano 44 40044 Pontecchio Marconi Italy a Tel 39 051 6782006 Fax 39 051 845544 2 http www elcontrol energy net ener n el sales elcontrol energy net 5 10 EN50160 CONFORMITY HARMONIC VOLTAGE ccccccee
6. Vizzano 44 40044 Pontecchio Marconi Italy am Icontrol Tel 39 051 6782006 Fax 39 051 845544 2 http www elcontrol energy net sales elcontrol energy net energy net PQ Studio User s Manual Rel PQS 0 2 Power Quality analysis software in Windows environment for the JUPITER professional analyser File Setup Options View Window Help 4 4 4 gt gt gt M 2J 100007 4 28 2005 07 58 18 250V div 250V dw _ ORNS RSS PO 00 4 Time base 2 HOms div Window pasition lt Reference channel V of 163 7 0 00 2504 d 0 00 oor 0 00 CH3 250A div 0 00 96 0 00 Time base agendis y 10ms div 0 00 0 00 96 Boe 0 00 96 Window position 0 00 0 00 0 00 4 28 2005 07 58 12 4 28 2005 07 58 13 5164 22 4 28 2005 07 58 15 17272 46 4 28 2005 07 58 16 17286 48 4 28 2005 07 58 17 17257 27 4 28 2005 07 58 18 17304 57 4 28 2005 07 58 20 18088 88 4 28 2005 07 58 21 18389 40 4 28 2005 07 58 22 18398 59 V 0 4 11 07 52 23 12120 amp 3 lt Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 1 of 1 Vizzano 44 40044 Pontecchio Marconi Italy Tel 39 051 6782006 39 051 845544
7. interarmornicc Mec sure 1 2 3 46 6 7 8 9 1011 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 20 30 31 1 Valore efficace di interarmeoni a V EMS calme of 2 th TIS 40 11 12 13 14 15 16 17 48 19 20 21 22 23 24 25 26 27 28 29 30 31 Gig interharmonic group spectrum uk 309 111315 4120 Frequenza Rel User s Manual Rel PQS 0 2 Frequency Hz P101 000 TIUCUH LY ITIUVUIT auurmo notice Page 14 of 14 Vizzano 44 40044 Pontecchio Marconi Italy Tel 39 051 6782006 39 051 845544 2 http www elcontrol energy net ener Y n el sales elcontrol energy net Gruppe interamienico 2 hi rias TII eroe EJ Spettro Armonico V3 13 20050530 000 MANUAL PHASE rm nr Sot mix intera rmonk intergrmopme sien ITI 1 di interarmenk a V BMWS caine ui MI in ee 102 1 56 7 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Gisg interharmonic subgroup spectrum Prequenza Hz Frequency Spectrum V3 13 20050428 000 TIMING Spectrum V3 13 20050428 000 TIMING 122456 7 9101112131415161718192021 22232425262728293031 12 5 6 7 8 9 10111213141516171819202122232425282728293031 00 V 12345 6 7 8 9101112131415161718 192021 2223242526
8. Italy Tel 39 051 6782006 39 051 845544 2 http www elcontrol energy net ener Y n sales elcontrol energy net 5 11 List of SAGS events Elcontral Energy Met SpA EMS01 60 Sags Eventa Durata Interruption 2775 _______ 3 342 5 Swell 449 ms Sell 374 Sell 125 Interruption 04705 2005 18 18 03 2008 Interruption 040572005 18 18 05 125ms O O P Interruption 125 ms oH SS 18 18 03 o 5 462 ms 11 ____ Interruption __ 0470572005 18 18 05 O o 125ms OZ o 12 Interruption 0405 2005 18 18 05 O fO O O dogal 13 1045 2005 18 18 05 O GE ms TEK 439ms 1 295 ________ Dip 1 0405 2005 18 18 08 1 59 Swel __ ___ SOUS 18 18 10 837 ms 1098 _________ __ Dip O 0405 2005 18 18 10 1 29 Swel O 0470572005 18 18 11 armaj 5 5 O 1 245 Dip SONS 18 18 13 150 2725 74 _______ _ O O P ma p ms 0452005 1818417 212 D OO S 13225 ______ 0415 2005 18 18 29 04 05 2005 18 18 29 1608 Po i PO 37 4 Dip 0452005 1818298 5 04572005 18 18 32 949 ms 04572005 18 19 32 25 0 ms L Dip 0405 2005 18 18 32 12 5 5 04 5 2005 18 18 32 12 5 L Lip 04512005 18 18 32 37 4 L Dip 0452005 18 18 32 37 4 __ 0452005 18 18 32 37 4
9. 4 Dp 0405 2005 18 18 32 25 0 ms Swel 041015720105 18 18 e 4 e 3 fa Dip 0410512005 18 18 26 1 9 stampata il OF 6005 16 14 07 Pag 1 Er red ER erg Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 44 of 44 Vizzano 44 40044 Pontecchio Marconi Italy Tel 39 051 6782006 39 051 845544 2 http www elcontrol energy net ener Y n el sales elcontrol energy net 5 12 SAGS events table Elcontral Energy Met SpA EMS0160 Pistudia Tabella Sanz Uims 0015 lt 05 ots 05 poset moe stampata il 70672005 16 15 51 1 rcd 1 Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 45 of 45 39 051 6782006 39 051 845544 Vizzano 44 40044 Pontecchio Marconi Italy http www elcontrol energy net sales elcontrol energy net energy net Ficontrol 5 13 SAGS array graph cL Ee ee Ede de L L o si n E Eg mn 5 5 amp 4 a stampata il OF 0672005 16 17 05
10. s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 28 of 28 Vizzano 44 40044 Pontecchio Marconi Italy p Tel 39 051 6782006 Fax 39 051 845544 2 http www elcontrol energy net ener sales elcontrol energy net parameters does not fall within the 95 threshold the NOT PASSED message is given To the contrary the PASSED message is given only when all parameters pass it CRIE F L kg m mum NH 3 20160 Statistics 7009091 9 000 201 60 gt x Power Frequency L1 Power Frequency L2 Power Frequency L3 Supply V Variations L1 Supply Y Variations Le Supply V Variations L3 Supply V Unbalance 90 91 92 93 945 95 96 97 98 99 100 3 3 2 EN50160 conformity harmonic voltage The analysis is carried out on the harmonic distortion values of the voltages referring to the fundamental for each one of the three phases Also in this case the values are averaged over 10 minutes and the threshold is 95 of the time referring to the total recording duration If one of the parameters does not fall within the 95 threshold the NOT PASSED message is given To the contrary the PASSED message is given only when all parameters pass it 01 60 Harmonic V 200250478 000 50150 EN50160 compliance FAILED This manual is subject to modifications without prior notice HH M Rel
11. User s Manual Rel PQS 0 2 Page 29 of 29 Vizzano 44 40044 Pontecchio Marconi Italy a Tel 39 051 6782006 Fax 39 051 845544 2 http www elcontrol energy net ener Y n el sales elcontrol energy net 3 3 3 List of SAGS events A chronologically ordered list contains all of the SAGS events recorded in the measuring campaign There can be three types interruptions losses of voltage Dip or overvoltage Swell Every line depicts a different event and is characterised by the type the starting instant the duration and possibly by the maximum or residual voltage value expressed in absolute value By clicking on the buttons in the title bar you call up the event sorting function You sort in increasing order with the first click and in decreasing order with the second click Sags Events lt 200504 78 000 50160 gt Begin Duration Umax 4128 2005 08 02 53 99 9ms 4128 2005 08 02 53 1 145 4128 2005 08 02 53 1 515 4126 2005 08 02 54 2 675 4728 2005 08 03 05 1 115 4728 2005 08 03 05 1 515 412812005 08 03 06 1 305 4128 2005 08 03 08 25 0ms 4128 2005 08 03 08 25 00ms 4128 2005 08 03 08 1 205 4728 2005 08 03 08 1 445 4728 2005 08 03 09 adams 4728 2005 08 03 09 1z2 5ms 4128 2005 08 03 09 agams 4128 2005 08 03 09 1 315 4128 2005 08 03 10 31zms 12672005 08 03 10 1z 5ms 4728 2005 08 03 12 1 015 4728 2005 08 03 10 1 195 4728 2005 08 03 12 2 615 4728 2005 08 03 14 22 5 4728 2005 08 03 14 3 745 4
12. 160 amp 1409 lt 120 7 20 2005 10 25 00 Lnergy Net So As for the other types of campaign there is a main window that gives all the data regarding the instrument s configuration status The EN50160 card displays the parameters set by the user for carrying out the analysis and hence of the campaign Please refer to the JUPITER electrical energy quality analyser manual for more detailed explanations regarding the analysis limits and criteria 2005051 9 000 501 60 gt Unom phase neutral 55 Dips Threshold of Unom 2 Hysteresis of 2 Gwell Threshold of Unom 11 Hysteresis of Unom E Interruptions uoce Threshold af Unam E Hysteresis 2 of Unom En Act arg d The View menu and toolbars set themselves up for the campaign in question You can note that now five new views and a brand new control bar appear 2 BEI 3 31 EN50160 conformity frequency changes and voltage unbalance Here the result of the analysis concerning the time percentage referring to the duration of the entire Campaign is represented for which the frequency values averaged over 10 seconds remain within the tolerance threshold established by the regulations 95 The same applies to the changes and the power supply voltage unbalance however with an integration time equivalent to 10 minutes If one of the Rel User
13. 26 27 28 29 3 31 3 39 0 77 75 2 31 75 1 07 So 2 83 1 18 2 09 1 14 1 37 1 26 1 13 1 20 95 0 59 Eg L kri i Br 10 41 12 13 14 15 16 17 18 18 20 21 22 23 24 25 26 27 2829 50 31 ni 1 2 a 4 5 6 8 9 10 11 is possible to change display mode of the spectrum and of the relevant measurements using 5 bg Gg big big 5 s toolbar you choose between harmonic and interharmonic spectrum with the first 6 buttons whereas you change between linear scale or logarithmic scale only for the axis of the ordinates with the last button on the right shown with a yellow grid Some examples Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 13 of 13 Vizzano 44 40044 Pontecchio Marconi Italy E Icontrol Tel 39 051 6782006 Fax 39 051 845544 2 http www elcontrol energy net sales elcontrol energy net energy net Spectrum V1 11 20050428 000 TIMING 12 3334 16 16 1 19 20 2 22 23 24 24 27 27 29 29 31 2 24 98 7 8 9 1011 12 3314 18 18 17 18 18 22 2 2222 24 36 2 27 28 29 0 1 G harmonic spectrum Gruppo armonico Spettro Armonico V3 13 20050530 000 MANUAL PHASE Harmonic group EE 1 2 3 4 5 8 7 8 9 10 11 42 13 14 16 16 47 18 19 20 21 22 23 24 26 26 27 28 20
14. 30 31 ETT fifth barmonic current reu ue cj 1 1 179 d y Y lu 1 LA IK 21 1 RET zal Ay F UR 410 12 Ty T I 123 4 5 6 7 8 9 10 41 12 43 44 15 46 17 18 49 20 21 22 23 24 25 26 27 28 29 30 31 Frequenza Hz Gg harmonic group spectrum Frequency armonico Spettro Armonico MES 13 20050530 000 MANUAL 3 PHASE _ 1 Harmonic subgroup r4 E n G 12 0 0 00 v D 1 226 Ea 2 716 mV 3 785 mV 4 218 5 5 4 55 H 6 157 ri 7 1 23V 8 76 5 m 776 y 169 sort See 1 320 ud 209 wo 620mv 982m 0 118 1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17 18 18 20 21 22 23 24 25 26 27 28 29 30 31 BM g 137 oy 312 my 60 6 mV 372 mV B 140 a 184 mV 109 mV m 706 352 mV 548 mV m 179 LE 208 mV 198 mv 228 E i m 104 __ o M E u PERH 123 45 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 1 if 5 21 zz I SHI zx zr zuo dua My 155 Hi ao Gsg harmonic subgroup spectrum l Frequenza Hy Frequency Hz Gnippe interamienico Spettro Armonico v3 13 20050530 000 MAN AL 3 PHASE
15. 43 434 351 333 7V 331 4V 74 77A 74 66 79 724 d Window position 5 18 2005 23 49 48 812 358 359 3 358 5V 80 90A 80 78A 84 63A lt B 5 18 2005 23 50 00 822 402 331 5V 330 6V 75 994 74 66 78 494 5 18 2005 23 50 04 811 385 331 5V 331 4V 74 77A 75 89A 79 72 _ Reference channel 5 18 2005 23 50 11 141 332 2V 332 9V 74 77A 74 66 79 72 on Single Ready Elcontrol Energy Net Dc f The View menu and the toolbar now change appearance adapting themselves to this type of campaign the spectrum analysis trend and vector meter are no longer available A new button tied to the window with the list of the events previously mentioned is however enabled Por Por GP In going back to the configuration window peak value set as the trigger threshold is given in the Transients card together with the trigger sources for the voltages and currents 2005051 8 000 TRIGGER DARK Trigger source Trigger source Trigger mode These trigger sources can be enabled singly or together One important feature of this type of campaign is that events captured with trigger thresholds and different sources can coexist in the same record So every event is accompanied by the parameters with which it was detected and this information will be updated on this card at the time it is displayed Lastly the trigger mode se
16. 6782006 Fax 39 051 845544 2 http www elcontrol energy net sales elcontrol energy net energy net Find Record Date and Time mer 18 mag 2005 v 234602 m dB Im Number Find by record number Set the date and time of the desired record and press OK Positioning is also possible based on the corresponding number of the record To do this select the box Find by record no enter the desired record number and press OK Now all of the windows with the displayed measurements and graphs will be updated to the set record Lastly there is a scroll control on the right for quick moves 3 1 6 Grid with rms measurements in Excel style By selecting menu item View Records a window containing a grid in Excel style is displayed Its lines represent the campaign s records in chronological order whereas every column contains the rms value of the parameter shown in the first line Survey lt 20050518 000 MANUAL gt Date Time y PF cap V var Hz 1812005 23 46 01 231 31 35336 46 11868 93 50 00 1 08 034 5 18 2005 23 46 02 231 28 50 95 0 99 35354 70 50 00 109 000 000 5 18 2005 23 46 03 231 29 50 97 0 99 35354 35 PESEE 50 00 110 o35 ooo ooo 5 18 2005 23 46 05 231 30 50 96 0 941 5357 66 5000 11 036 5 18 2005 23 46 06 231 29 0 40 5
17. Cosphi value from the 1 to the 31 harmonic for each phase in percentage value XXX is a progressive number from 000 to 999 and is used in subdividing a very long campaign WXxXxX file with the samples of the waveforms of V and for each phase is a progressive number from 000 to 999 and is used in subdividing a very long campaign The character used as the field separator is Tab ASCII code 09 For the first three files every line corresponds to a record of the measuring campaign whereas every column contains the amplitude measurement value indicated in the first line On the other hand every record is saved on six lines for the file with export of the samples the first three correspond to the voltages V1 V2 and and the second three to the currents 11 12 and 13 Owing to the nature of this export the resulting file may come large in size It is therefore recommended to make several partial exports 3 2 Transients Campaign As you can see the campaign configuration window as well as the other graphic views are perfectly similar to those already described for the Timed type of campaign The differences are minimum and regard a supplementary view with the list of overvoltage and overcurrent events detected during analysis of the system Moreover some broken lines one vertical and two horizontal have been added in the oscillograms They depict the instant and the minimum and maximum trigger thresholds meant as
18. It concerns the frequency changes in voltage losses of voltage overvoltages between phase to phase short and long interruptions power supply unbalance and the harmonic spectrum of the voltage Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 27 of 27 Vizzano 44 40044 Pontecchio Marconi Italy a Tel 39 051 6782006 39 051 845544 2 g http www elcontrol energy net ener Y n el sales elcontrol energy net fie pip yew Window Help F 20050519 000 50160 248450160 Statistics lt 20050519 000 1501 60 1 150 8015010 Harmonie lt 20050519 000 1501 60 2386 221 venue Welt 92 95 973 07 222 ence L1 4 fua De X of Unom X of Uncen Powe Frequemey 12 ower Frequesey LI v 5 of Unom Hysteresis X of Uncen Men V Vattatians 1 of Unom X of Unom V 12 fupply V 13 Bins 52533323158 3235153255 Supply V Unbalance FP Sags vents 20050 517 000 1501 60 Duration Durabon 0 013 0 15 0 15 0 55 0 55 15 gt US lt 200 lt
19. enabled if the cursor is left for more than 2 seconds on a certain point of the graphs a small indicator with the measurement expressed in the units of measure indicated on the vertical and horizontal axes of the system of reference in that point is automatically displayed In our case the Volts or Amperes and the number of milliseconds will be measured starting from the beginning of the buffer Stars 2005051 3ISHASE Just use the Time base switch to increase or decrease resolution by time units Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 16 of 16 Vizzano 44 40044 Pontecchio Marconi Italy Tel 39 051 6782006 Fax 39 051 845544 2 http www elcontrol energy net sales elcontrol energy net energy net PB Waveform V1 V2 V3 Star lt 20050518 000 MANUAL All of the channels are grouped together in a single grid when you click on the Single grid control Just set the CH1 CH2 or switches to increase or decrease the amplitudes of the signals Changing the position of the display interval to another point of the record is simple with the Window position scroll bar This option is useful for searching for particular events 3 1 5 The time trend of the rms measurements You can enable a function called trend for the rms values that lets you plot t
20. energy net energy net the units of measure indicated on the vertical and horizontal axes of the system of reference in that point is automatically displayed Trend lt 20050518 000 MANUAL gt 44 Rec 12 5 18 2005 23 45 14 23 48 32 3 1 5 1 Recorder toolbar When the measurements trend window is displayed during a campaign the recorder function is enabled It lets you make the measuring campaign scroll by creating an animation as if it were a measurement in real time 4 44 4 gt gt is possible to move to the beginning or of the recording and perform a normal or fast forward rewind You can momentarily stop execution during reproduction by pressing the pause button Press the pause button again to resume execution of the measurements trend If there are other secondary views displayed together with the measurements trend they will be coupled with the recorder function i e if the trend is paused so will the other views When the pause function is enabled the secondary views display the first record in the display interval of the measurements trend 3 1 5 2 Setting the number of tracks and the parameter associated with a track You can customise the number of tracks or channels displayed in the trends window and the parameter associated with each track using menu item Configuration Trend Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without p
21. fnd L2 Harm Cosphi L2 Harm V L3 Harm V of fnd L3 Harm L3 Harm 1 of L3 Harm Cosphi L3 Note when you select a harmonic measurement of V or the Cosphi value you have to specify the harmonic order in the relevant input box The changes made are permanent meaning that the program saves them in the configuration register so as to be able to restore them in the future in another work session 3 1 5 3 Indicators of the current record and random record search Right under the main menu is a small window indicating the number date and time of the record currently displayed in the measurements and graphs windows 00137 30 05 2005 16 03 27 While there is a reproduction in progress the indicators are continuously updated with the information concerning the current record If the campaign is momentarily put in pause status the window keeps the last values displayed On the other hand the indicators stay empty when just the measurements are displayed unless you enter the pause status and use the recorder function You can position yourself on any point of the measuring campaign with the Find Record function When you press the button located to the left of the indicators a window like this one is displayed Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 20 of 20 Vizzano 44 40044 Pontecchio Marconi Italy E Icontrol Tel 39 051
22. 128 2005 08 03 19 1z2 5ms 4126 2005 08 03 14 4 355 4728 2005 08 03 19 462 4728 2005 08 03 19 37 5 4 26 2005 08 03 19 25 00ms 4128 2005 08 03 19 1z2 5ms 4128 2005 08 03 19 1z2 5ms 4728 2005 08 03 19 25 0ms 4126 2005 08 03 20 4728 2005 08 03 20 gaagmz 4128 2005 08 03 19 1 295 co 5 Bc IO UI 2 3 3 4 SAGS events table This is another SAGS display mode A set of time and voltage intervals is defined in a two dimensional table The voltage intervals are expressed in percentage referring to the rated Unom voltage Every box is increased by a unit when a certain event is comprised within the duration and voltage value interval depicted by that particular box In this way we get a mapping with the density of the SAGS events Sags Table lt 20050428 000 50160 gt Urms Duration 0 015 lt 0 15 0 15 lt 0 55 0 55 lt 15 1 lt 35 3s lt 205 205 lt 605 im lt 3m gt 200 0 ueque gs 7 T 0 0 160 lt 200 140 lt 160 120 lt 140 110 lt 120 Unom 60 lt 90 30 lt 60 15 lt 30 5 lt 15 0 lt 5 Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 30 of 30 Vizzano 44 40044 Pontecchio Marconi Italy 9 Tel 39 051 6782006 39 051 845544 2 http www elcontrol energy net sales el
23. 2 http www elcontrol energy net ener Y n el sales elcontrol energy net Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 2 of 2 Vizzano 44 40044 Pontecchio Marconi Italy a Tel 39 051 6782006 Fax 39 051 845544 2 http www elcontrol energy net ener Y n sales elcontrol energy net PQ Studio Power Quality analysis software in Windows environment for the JUPITER professional analyser Table of Contents 1 GENERAL DESCRIPTION ecaiixsun E icri rrr ar ri cir an 5 1 1 THE MAIN WINDOW s ENEA 5 1 2 TRE AINE 6 2 THE MEASURING 7 2 1 PRELIMINARY NOTES 7 2 2 ORGANISATION OF THE MEASURING CAMPAIGNS ON THE nnns 7 3 DISPLAY AND PROCESSING OF A MEASURING CAMPAIGN 9 3 1 TIED CAMPAL N n 9 3 1 1 ECRIRE 12 S12 The TAD RTI 12 3 1 3 harmonic and interharmonic 5 13 3 1 4 The voltage and current 5 aene 15 3 1 5 The time trend of the rms
24. 2728293031 interharmonic spectrum S interharmonic spectrum with logarithmic scale The last two figures display the detailed harmonic spectrum The coloured bars depict the classic harmonics whereas the grey bars depict the interharmonics The frequency for each harmonic order is the multiple of the fundamental frequency for example we will have 1 ord 50Hz 2 ord 100 Hz 39 ord 150Hz and so on for a 50Hz frequency Similarly it will be 1 ord 60Hz 2 ord 120Hz 34 ord 180Hz etc for 60Hz frequency The interharmonic values on the other hand increase in 5Hz steps for a fundamental frequency of 50Hz and in 6Hz steps for a 60Hz fundamental frequency If the logarithmic scale is applied exemplified here in the complete spectrum but just as valid for any one of the other graphs we quickly get a magnification of the lowest percentage values Note how in one case it is at 50 at half scale whereas in the other case it is at 1096 3 1 4 The voltage and current waveforms Here we have a complete series of views that allow us to observe the waveforms for all of the voltage and current inputs in different combinations in detail We ll start off explaining the operation by taking a single window as an example The same concepts are however applicable to all the other windows of this type A waveform view is nothing other than a small oscilloscope The control panel is shown on the left side and on the right are the actua
25. Lond ___25 __ _ _ 0029514 ___ 25 00 5 00047 10051 oss __ LL LI3smv 00047 Loud 31 428mv _ 000 stampata il OF E005 15 55 35 Pag 1 Ec en end d lor 1 PR Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 36 of 36 Vizzano 44 40044 Pontecchio Marconi Italy Tel 39 051 6782006 39 051 845544 2 http www elcontrol energy net ener Y n el sales elcontrol energy net 5 4 The voltage and current waveforms Elcontrol Energy Met SpA 3 PHASE recon TETIZE Diagramma delle forme d andas1 2 3 Star re cord 16 07 17 VV VV M o PANT ANT ANT C Ll stampata il OF 62005 16 01 20 1 m RI Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 37 of 37 Vizzano 44 40044 Pontecchio Marconi Italy Tel 39 051 6782006 39 051 845544 2 htt
26. User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 6 of 6 Vizzano 44 40044 Pontecchio Marconi Italy a Tel 39 051 6782006 Fax 39 051 845544 2 http www elcontrol energy net ener Y n el sales elcontrol energy net 2 The measuring campaigns 2 1 Preliminary notes As previously mentioned JUPITER allows various pieces of information that characterise the electrical phenomena to be stored in the measuring campaigns The measuring campaigns can be carried out in two different modes e Manual the user manually decides when to start and stop data acquisition e Automatic the user configures one or more campaigns in a list of campaigns The automatic campaign manager continuously controls the status of the above mentioned list automatically executing the Campaigns it contains In turn there are three very distinct tyoes of campaigns e Timed the records with the information about the samples of the voltage and current input signals are saved in regular time intervals a minimum of 0 continuous flow of data to a maximum of 1 hour 8600 seconds e Transient the transient type of overvoltage and overcurrent phenomena are captured in the single or repetitive event mode 50160 the records contain the results of the electrical energy quality analyses established by the EN50160 regulations frequency change in voltage losses of voltage overvoltag
27. a symmetrical peak value compared to the neutral Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 24 of 24 Vizzano 44 40044 Pontecchio Marconi Italy Tel 39 051 6782006 39 051 845544 2 http www elcontrol energy net ener gy n el sales elcontrol energy net File Setup Options View Window Help uu cou hr Aw fr 2 00002 5 18 2005 234901 2005051 8 000 TRIGGER Timings Instrument setup General EN50160 Transients 250V div 250v div 250V div Voltage Current Peak m Peak 100 Trigger source Trigger source Time base 1 ms div Trigger mode Window position Reference channel Single grid k Trigger time Peak Peak PeakI1 PeakI2 PeakI3 5 18 2005 23 48 59 346 330 0V 453 40 74 77A 74 66 78 494 5 18 2005 23 49 02 632 411 2V 387 1 91 93 111 34 116 5 5 18 2005 23 49 08 575 713 4V 472 20 74 77A 75 89 79 724 2504 div 5 18 2005 23 49 11 460 411 2V 381 1V 90 70A 108 9 115 24 J 250A div 5 18 2005 23 49 16 989 391 6V 366 8V 88 25 108 9 112 84 5 18 2005 23 49 23 755 414 20 383 3V 91 93A 111 3A 115 2 Time base 5 18 2005 23 49 30 552 408 2V 375 81 90 70A 110 1A 117 74 B 1 ms div 5 18 2005 23 49 37 314 403 7V 376 5V 90 70A 110 1 115 24 5 18 2005 23 49
28. aph of a set of measurements You can select from one to four parameters columns for a maximum of 5000 records with the mouse then the measurements selected will be graphically represented in just as many oscilloscope type of quadrants contained in a new window when you select the option Make rms graph from the contextual Selection menu In this context it is possible to change the way of plotting the measurements from histogram to trend and vice versa If the number of selected records is greater than the quadrant s graphic capability you can actuate scrolling of the parameters shown in both directions using the buttons found in the lower left hand corner lt and gt Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 21 of 21 Vizzano 44 40044 Pontecchio Marconi Italy 9 Tel 39 051 6782006 39 051 845544 2 http www elcontrol energy net sales elcontrol energy net energy net Drawing select data 94 01 UI ROE 33276 55523 46 26 Ml 46 01 eiie 0 _ 23 15 0 91 time 24801 time Drawing feet Histogram of Records pum Date Wie cuts CO Trend sample Rate mm 00 00 Moreover this window shows fields that give respectively e the date of the records currently depicted i
29. ard offers other information regarding the name of the campaign user notes if any and the of recording Timed Transient or EN50160 20050428 000 TIMING 34 The last two cards complete the instrument configuration overview with the parameters regarding the settings for EN50160 analysis and the threshold settings for detecting electrical overvoltage and overcurrent phenomena These cards do not affect a Timed type of campaign and shall be explained further on 20050428 000 TIMING _ 3 20050428 000 TIMING Timings Instrument setup 50160 Transients Unom phase neutral EJ Hnterconnecte E Dips Threshold of UnomE B Hysteresis of Unom B j Trigger source Trigger mode Threshold of 110 Hysteresis of 4 E nu T Rosae Threshold of 2 _ Hysteresis 2 of Unom E s 1d LI Lie vzn In addition to the main window secondary windows with the numeric and graphic measurements can be viewed when the user selects them The following views are automatically shown by default when this type of campaign is opened Harmonic Spectrum V1 l1 Harmonic Spectrum 2 12 Harmonic Spectrum V2 12 Voltage Waveforms V1 V2 V3 referring to neutral Star Current Waveforms 11 12 13 Vector Meter Trend of the rms measurements and an Excel style grid whose lines represent the m
30. c harmonic spectrum in the other cases only the V and values in absolute value will be listed e One section with the graphic display of the V and harmonic spectrum in percentage value compared to the fundamental You can alter the size of the above mentioned areas by dragging the vertical separation bar between the two sections with the mouse You can sort the measurements by value from lesser to greater by pressing on the buttons of the title of a given column in the left section By default they are sorted by number of harmonic order first column on the left When positioning the cursor on the graphs the Point and Measure function is enabled if the cursor is left for more than 2 seconds on a certain point of the graphs a small indicator with the measurement expressed in the units of measure indicated on the vertical and horizontal axes of the system of reference in that point is automatically displayed In our case it will be the percentage value of the harmonic component and the number of harmonic order with the relevant equivalent frequency I TTE ar aM pee h 3 y 1 4 7 F gt i 7 Spectrum 1 I1 20050428 000 TIMING ERES of db 100 0 31 25 8 76 0 00 10 4 1 02 95 11 6 0 68 5 78 0 82 5 4 90 96 a 1 12 54 567 8 amp 5 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
31. cecceccecceccecceccuccucceccuccuecsecuesaecuccuccaecassacsaeeaseass 43 5 11 LIST OF SAGS EVENTS 44 5 12 SAGS EVENTS TABLE sccsccececcecceccececcecceccecccececucsuceecuecuucecaeceesauaucuecacsueaeceecueaucaesacsetaesauauseesacseees 45 5 13 SAGS ARRAY GRAPH cscscceccececcccecceccccccuccececaececaccuceucuecsucecaececsuuaecsesuuaueaecsecueaucaesecsaeaecseaereeseceaees 46 6 SYSTEM REQUIREMENTS 2 ccccccssceccecnscnscnscecnscnscnscscnscnscnscscnscnsensnsensensesensenscnscsensenscnsnsensensenensensensenseas 47 Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 4 of 4 Vizzano 44 40044 Pontecchio Marconi Italy Q Tel 39 051 6782006 NIC ener y n el sales elcontrol energy net PQ Studio Power Quality analysis software in Windows environment for the JUPITER professional analyser 1 General description PQ Studio is a software application in Windows environment that lets you process the data recorded by the JUPITER professional analyser of electrical energy quality PQ Studio is able to repeat all analyses performed by JUPITER on the system It therefore lets you reconstruct waveforms energy data and the events that occurred during the measuring campaign JUPITER saves the measuring campaigns on a Compact Flash CF type of memory The data stored in it can later be transferred onto the PC for analysis creating and prin
32. control energy net energy net 3 3 5 SAGS array graph In this case it is a graphic display of the distribution of the events taken into consideration Every coloured dot symbolises a different event We can therefore identify the different areas populated with anomalous phenomena with a simple visual analysis The duration scale is represented in logarithmic scale in order to cover an extensive time interval The values are comprised between 1 thousandth of a second and 1000 seconds 16 6 minutes Sags Graph lt 200504 28 000 50160 gt Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 31 of 31 Vizzano 44 40044 Pontecchio Marconi Italy a Tel 39 051 6782006 Fax 39 051 845544 2 http www elcontrol energy net ener Y n sales elcontrol energy net 4 Customising the graph colours If you want to change the default setting of the graph colours click on any point of the graph with the right mouse button or select the menu item Options Colours A window that lets you freely select the colours of the different areas of the oscillogram appears such as panel colour track colour pen colour etc Note the same number of tracks of the graph that you are configuring is given on the colour configuration window Depending on the case at hand it may be a number from 1 to 4 Colors settings Example layout Co
33. e between phase to phase short and long interruptions power supply voltage unbalance 2 2 Organisation of the measuring campaigns on the CF Every measuring campaign is stored according to a common procedure there is a directory in the CF root directory that acts as a container of all the campaigns and is called Survey At this level and for every new measuring campaign a directory is created its name will have this type of form YYYYMMDD NNN AAAA A where YYYY year month e DD day e NNN progressive campaign number from 000 to 999 it serves to identify the same type of campaigns over the same day e AAAA A user defined descriptive label A campaign is made up of An srv file which is the actual campaign file where the parameters characterising it are saved This is the document file for the program It is a very small file and its file name is the same as the directory containing it One or more XXXX files where XXXX is a number from 0000 to 9999 where the records with the measurements or samples of the waveforms are saved Depending on the set acquisition frequency these files may reach dimensions of about one megabyte There may be a file with srx extension where some additional support data are saved Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 7 of 7 Vizzano 44 40044 Pontecchio Marconi Italy E Ico
34. easurements for each record Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 11 of 11 Vizzano 44 40044 Pontecchio Marconi Italy P r Q Tel 39 051 6782006 Fax 39 051 845544 2 http www elcontrol energy net sales elcontrol energy net energy net All views useful for analysing the campaign are accessible from the View menu or even more directly by using the toolbar ieee FS Note that a label with short description of the button pointed at appears when moving over the bar with the mouse 3 1 1 The rms measurements This window displays the main rms measurements both three phase and of the single phase such as voltage V current 1 cose frequency f active power P reactive power apparent power S power factor PF the four counters of active and reactive absorbed generated and inductive capacitive power Whaps Whgen the apparent power counter Vah and the average power factor PF avrg Also the current of the auxiliary channel is displayed in the lower right hand corner rms lt 20050428 000 TIMING gt ra Three phase B3 o n3 elegi arx Vm 5 8 5 EX EBEEE w w oen AL MENNERE SUM EECR C MEE 51 va gt VW x3 nu E ENIM Rete wh abs kWh
35. emainder 3 2 4 Grid with rms measurements in Excel style See paragraph 3 1 6 3 2 5 The transients list All of the events recorded during the measuring campaign are shown in a list in chronological order Every line corresponds to a different transient The progressive number of the event the date and time including the milliseconds of the trigger instant and a set of six values with the maximum voltage and current peaks Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 26 of 26 Vizzano 44 40044 Pontecchio Marconi Italy 9 Tel 39 051 6782006 39 051 845544 2 http www elcontrol energy net sales elcontrol energy net energy net detected during the entire manifestation of the phenomenon are listed in the columns These values are therefore not to be confused with the peak value that caused the trigger event By clicking on the first column the one with the progressive numbers of the transients you select the event you want to view it will be highlighted with a small red arrow All of the other views will be immediately synchronised with the relative information including the control window where the configuration parameters are given You can also skim through the list using the keyboard up arrow down arrow and the scroll control found in the toolbar The records with information about the samples are saved in
36. heir trend over time The figure below represents the default window with the trends of 4 channels voltage V current 1 active power P and the three phase power factor PF In this case the scale factor for the ordinates is automatic and it keeps the signal always at the maximum resolution 80 of the full scale As for the x axis the following consideration applies it is fixed and corresponds to 60 samplings expressed in the measuring campaign frequency time When the frequency time is equal to 0 a value equivalent to 1 second is forced so the time display window will be 60 x 1 60 seconds 1 minute If for example the frequency time were to be 5 minutes the interval would be equivalent to 60 x 5 300 minutes 5 hours When the last plotted value exceeds 95 of the display time interval the tracks are moved to the left deleting the oldest data so the displayed data always correspond to the last 60 x sampling time seconds When positioning the cursor on the graphs the Point and Measure function is enabled if the cursor is left for more than 2 seconds on a certain point of the graphs a small indicator with the measurement expressed in Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 17 of 17 Vizzano 44 40044 Pontecchio Marconi Italy P r Q Tel 39 051 6782006 Fax 39 051 845544 2 http www elcontrol energy net sales elcontrol
37. l oscillograms How many and which signals will be displayed will depend on the type of view selected There are 7 different combinations V1 V2 V3 star V1 V2 V3 delta 11 12 13 1 11 2 12 V3 I3 and 14 auxiliary channel Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 15 of 15 Vizzano 44 40044 Pontecchio Marconi BO Italy P CO r Tel 39 051 6782006 39 051 845544 2 http www elcontrol energy net ener n sales elcontrol energy net Waveform 1 2 3 Star lt 20050518 000 MANUAL gt 2 250474 gt 2 Time Window position gt 149 37 48msec Reference channel Single grid Gan The control panel is made up like this three switches for changing the gain or amplitude 5 for each channel a common switch for changing the time base a scroll bar for positioning 7 250V div the display area or window inside the record remember that a record is equivalent to 60 Time base periods of the fundamental frequency and a switch for combining all the channels in a single grid In this case it will be necessary to select the corresponding channel in order to be able to use the Point and Measure function a track Reference channel Single ond When positioning the cursor on the graphs the Point and Measure function is
38. lor Selection Plot NI Plot area EB Gnd 1 Ans a Text Panel 7777 e Select the channel you want to configure by pressing the button CH1 CH2 CH3 e Select the area whose colour you want to change by pressing one of the buttons found in the Colour selection group A window like this appears Colore Color di base NIE Colon personalizzati 8 8 B B B B B D efinigci calori personalizzati gt gt Annulla e Select the desired colour and press e Repeat the preceding steps for the other areas to be modified Lastly press the OK button in the configuration window of the graph colours The changes made will be shown on the original graph Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 32 of 32 Vizzano 44 40044 Pontecchio Marconi Italy a Tel 39 051 6782006 Fax 39 051 845544 2 http www elcontrol energy net ener Y n el sales elcontrol energy net 5 Printing documents The program lets you print all of the measurements and previously illustrated graphs on both black and white and colour printers for paper filing and for filling in system analysis reports You can print with the paper in either portrait or landscape orientation without distinction It is also possible to get a print preview on the screen for all prints before actually printi
39. n the oscillogram total number of selected records e the recording frequency of the records Frequency The recording times of the first and last record currently shown on the graph are shown at the ends of the quadrant s abscissa When positioning the cursor on the graphs the Point and Measure function is enabled if the cursor is left for more than 2 seconds on a certain point of the graphs a small indicator with the measurement expressed in the units of measure indicated on the vertical and horizontal axes of the system of reference in that point is automatically displayed 3 1 6 2 Exporting a set of measurements To export data select the records to be exported with the mouse press the right mouse button and then select the option Export from the contextual Selection menu The records in the selected range will be automatically exported while displaying a window of this type Measures export Export setup Range _ lcontrol Energy Net POStudio Survey For more details consult the paragraph 3 1 8 3 1 7 The vector meter The fundamental parameters of the voltages between phase and neutral and of the currents are depicted on this page in vector mode i e in module and phase The panel on the right side of the graph lists the voltages and currents with the respective modules and phase angles and farther down the cosine of the Rel User s Manual Rel PQS 0 2 This man
40. ncy Note as every record includes 60 periods irrespective of the basic frequency it results that if the frequency time is equal to 1 sec it as well corresponds to continuous acquisition 20050428 000 TIMING In returning to the description of our cards we find a first part regarding configuration of the JUPITER analyser in the second card called nstrument Configuration In particular the transformation ratios of the voltage current and auxiliary channel inputs the type of current sensor Clamp on Flexible or TA any Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 10 of 10 Vizzano 44 40044 Pontecchio Marconi Italy Icontrol Tel 39 051 6782006 Fax 39 051 845544 2 http www elcontrol energy net sales elcontrol energy net energy net reversal of the current sensors the type of connection with two three or four wires the nominal frequency for the harmonic analysis and the enabling of the auxiliary input and scale extended for the voltage inputs are given Also the version of the JUPITER firmware is indicated All of this information illustrates the conditions in which the measuring campaign was performed EA 20050428 000 TIMING _ al PT Ratio r nvertion a F Ta E e AUX Ratio E m puo Extended V ok Scale um E RUM SC Rel a The Main c
41. ng The printer management criterion is the Windows environment standard The print preview and print refer to the currently selected window i e the one in the foreground characterised by the active title bar So before printing click on the desired window or select it using the Window command of the main menu A few print examples are shown below Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 33 of 33 Vizzano 44 40044 Pontecchio Marconi Italy Tel 39 051 6782006 39 051 845544 2 http www elcontrol energy net ener Y n el sales elcontrol energy net 5 1 Information about the measuring campaign Elcontral Energy Met SpA MANUAL 3 PHASE Informazione campagna me Configurazione dello strumento Si 0 00 01 01 F 0 01 511100123 stampata il 0672005 15 53 26 Pag 1 ned ER PR Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 34 of 34 Vizzano 44 40044 Pontecchio Marconi Italy Tel 39 051 6782006 39 051 845544 2 http www elcontrol energy net ener Y n el sales elcontrol energy net 5 2 Grid with rms measurements in Excel style Rel User s Manual Rel PQS 0 2 This manual is subject to modifica
42. ntify the number of the records of the desired export interval Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 23 of 23 Vizzano 44 40044 Pontecchio Marconi Italy Icontrol Tel 39 051 6782006 Fax 39 051 845544 2 http www elcontrol energy net sales elcontrol energy net energy net Measures export Export setup O Bange C Programmi Energy Net POStudio Survey Progress is displayed during export and the Export button becomes Stop The operation may even last a few minutes depending on the type of campaign and its duration You may however stop its process at any time by pressing the Stop button The export files are created in the directory indicated in the relevant input box The directory where the measuring campaign resides is presented by default The export files are divided into four types and can be distinguished based on their file extensions e with the same rms measurements contained in the Excel style of grid XXX is a progressive number from 000 to 999 and is used in subdividing a very long campaign e file with the measurements of V and and of the Cosphi value from the 1 to the 31 harmonic for each phase in absolute value XXX is a progressive number from 000 to 999 and is used in subdividing a very long campaign e file with the measurements of V and and of the
43. ntrol Tel 39 051 6782006 Fax 39 051 845544 2 http www elcontrol energy net sales elcontrol energy net energy net For example let us suppose that the CF memory has been recognised by the operating system as a new unit with the letter F then the structure of the files will be as follows Survey 20050406 000 Manual Campaign 20050406 000 Manual Campaign srv 20050406 000 Manual Campaign 0000 20050407 000 Manual Campaign 0001 20050408 000 Manual Campaign 0002 20050409 000 Manual Campaign n 20050409 000 Manual Campaign srv 20050409 000 Manual Campaign 0000 20050410 000 Manual Campaign 0001 20050110 000 Automatic Campaign 20050110 000 Automatic Campaign srv 20050110 000 Automatic Campaign 0000 20050111 000 Automatic Campaign 0001 20050112 000 Automatic Campaign 0002 20050113 000 Automatic Campaign 0003 At this point a small clarification becomes necessary Up until now it has been said in an entirely general way that a measuring campaign 15 a set of binary data organised in records As is easy to imagine what is contained will depend on the nature of the campaign A record is made up of the samples for each input signal 3 under voltage and 4 under current for a total of 60 signal periods which at the frequency of 50 Hz are equivalent to 1 2 seconds of recording or 1 second at 60 Hz is now impor
44. nts list Elcontral Energy Met SpA TRIGGER Lista dei transienti L2 M s nus1585561759 4105 3888 agg v 7354A ragg Af 26234 LB 1405 2005 18 56 36 214 3939 v 3549 v Rea v 72324 r466 Af 9512 A L8 1405 2005 18 56 49 084 5370 9788 raag Af 220 9 a5 554 9145 2005 18 57 514 12563 v 415 v 4157 4 101854 stampata il OF 6005 16 05 22 Pag 1 TI d TR tT Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 40 of 40 Vizzano 44 40044 Pontecchio Marconi Italy Tel 39 051 6782006 Fax 39 051 845544 2 http www elcontrol energy net ener Y n sales elcontrol energy net 5 8 The voltage and current waveforms transients Elcontral Energy Net SpA TRIGGER PirStudia recon OOS Diagramma delle forme d andas1 H Dabs econ 12212 stampata il OF 06005 15 08 31 1 cr d ee Tce Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 41 of 41 Vizzano 44 40044 Pontecchio Marconi BO Italy E Icontrol Tel 39 051 6782006 Fax 39 051 845544 2 http www elcontrol energy net sales elcontrol energy net energ
45. p www elcontrol energy net ener Y n el sales elcontrol energy net 5 5 time trend of the rms measurements Elcantral Energy Met SpA 3 PHASE Diagramma dei trend stampata il OF 6005 16 31 19 1 eri s ee ee 4 2 Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 38 of 38 Vizzano 44 40044 Pontecchio Marconi Italy Tel 39 051 6782006 39 051 845544 2 http www elcontrol energy net ener Y n sales elcontrol energy net 5 6 The vector meter Elcontrol Energy Met SpA 3 PHASE recon TETIZE Vettorimetra Dabs record XYDEZTIS 16117 17 Vv 220 1 900 wa S2 4 220 210 77 1 358A 8538 IZ 48 24 3226 5 47 1967 20581 0 994 ind cose 0 991 ind 583 976 ind V Unbalance 0 4 57 SU 15 004 diy stampata il OF 6005 16 02 44 1 CAT quae cen beens de eee eee Mee eee Heed TT TS Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 39 of 39 Vizzano 44 40044 Pontecchio Marconi Italy Tel 39 051 6782006 39 051 845544 2 http www elcontrol energy net ener Y n el sales elcontrol energy net 5 7 The transie
46. rior notice Page 18 of 18 Vizzano 44 40044 Pontecchio Marconi Italy 9 Tel 39 051 6782006 39 051 845544 2 http www elcontrol energy net sales elcontrol energy net energy net Trend settings Channel 1 Harm Order H T Enable 1 bm Channel 2 Harm Order Enable Channel 3 Pow Harm Order Enable Channel 4 n 4 Order Enable Cancel The number of tracks displayed may vary from a minimum of 1 up to a maximum of 4 Select the box Enable to enable disable a channel To change the parameter associated with a channel select it in the box regarding the desired channel The possible parameters are V Thd ref V fnd L1 Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 19 of 19 Vizzano 44 40044 Pontecchio Marconi Italy 9 Tel 39 051 6782006 39 051 845544 2 http www elcontrol energy net sales elcontrol energy net energy net Thd ref V rms L1 Thd ref fnd L1 Thd ref rms L1 Thd ref V fnd L2 Thd ref V rms L2 Thd ref fnd L2 Thd ref rms L2 Thd ref V fnd L3 Thd ref V rms 13 Thd ref fnd L3 Thd ref rms L3 Harm V L1 Harm V of fnd L1 Harm L1 Harm 1 of fnd L1 Harm Cosphi L1 Harm V L2 Harm V of fnd L2 Harm L2 Harm 1 of
47. sequence Indication of the current record may not coincide with the progressive number of the transient above all if there are events captured in the Automatic trigger mode Transients lt 2005051 8 000 TRIGGER gt BUE Trigger time Peak Peak Peak PeakI2 PeakI3 511812005 23 48 59 346 473 0 330 0 4537 74 77 7466A 78 490 511812005 23 49 02 632 427 41l zv 387 1 91 934 111 54 116 54 511812005 23 49 08 575 451 24 Tl3 4V 472 24 75 89 79 725 511812005 23 49 11 460 424 0V 411 2v 381 1v 9 0 106 9 115 24 6 18 2005 23 49 16 983 4037 391 6v 3566 8v 56 254 108 9 112 84 511812005 23 49 23 755 42 14 414 383 2V 91 934 111 34 115 24 6 18 2005 23 49 30 552 419 5y 4 8 2Vv 90 70 110 14 117 74 511812005 23 49 37 314 424 403 7 35 90 704 110 14 115 24 1 3 4 5 6 B 5 18 2005 23 49 43 434 351 0v 333 7V 331 4V 74 77 amp 74 66A 79 5 18 2005 23 49 48 812 50 04 359 991 356 5 B0 90A 80 78 B4 534 5 18 2005 23 50 00 822 4 2 2vV 331 5v 330 0V 75 994 7466A 78 494 5 18 2005 23 50 04 811 355 0v 331 5V 331 4V 74 77 75 094 79 724 5 18 2005 23 50 11 141 335 2V Jda gY 33A 4 77 7 3 3 EN50160 Campaign An analysis of the quality of the electrical energy according to the EN50160 regulations is conducted with this type of record
48. so the appropriate icons in the toolbars are enabled e File operations associated with the opening closing printing and print preview of a measuring campaign file Configuration command for configuring the trend of the rms measurements real time measurements trend Options setting of colours for the different graphs waveform harmonic spectrum trend View display selection of the numeric measurements and graphs different tool bars and the status bar Window set up of the arrangement of windows or to call up a certain window in the foreground 2 display of the window with the program information and online help Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 9 of 9 Vizzano 44 40044 Pontecchio Marconi Italy a Tel 39 051 6782006 Fax 39 051 845544 2 http www elcontrol energy net ener Y n sales elcontrol energy net File Setup Options View Window Help ux m co 44 4 gt gt gt aJ 00007 4 28 2005 075818 6 Gs Gig Gisa eR en 20050428 000 TIMING Timings instrument setup General EN50160 Transients 250v div 250V div 250V div _ 10ms div UR PERTH 00 Y Time base 4 E rroa nuaran Window position
49. t during the campaign is given Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 25 of 25 Vizzano 44 40044 Pontecchio Marconi Italy 39 051 6782006 39 051 845544 2 http www elcontrol energy net sales elcontrol energy net energy net e Single the event is made up of just one record regardless of the phenomenon s duration e Automatic the event is made up of one or more records that completely contain the entire phenomenon 3 2 1 The rms measurements paragraph 3 1 1 3 2 2 The THD measurements See paragraph 3 1 2 3 2 3 The voltage and current waveforms Some broken lines one vertical and two horizontal have been added in the oscillograms They depict the instant and the minimum and maximum trigger thresholds meant as a symmetrical peak value compared to the neutral When the events in the list of transients are skimmed through the record interval containing the trigger instant is always displayed The duration of this interval depends on the time base set on the control panel to the left of the oscillograms If the outline conditions so permit at least the 20ms preceding the trigger instant are displayed 2 BOM A div 2 25 2 250 Adiv Time base n ms div Window position Reference channel Single grid The same characteristics described in paragraph 3 1 4 apply to the r
50. tant to establish that the entire PQ Studio application is broken down into measurement records The movements within the recording the graphs calculations and everything else are based these packets of information Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 8 of 8 Vizzano 44 40044 Pontecchio Marconi Italy E Icontrol Tel 39 051 6782006 Fax 39 051 845544 2 http www elcontrol energy net sales elcontrol energy net energy net 3 Display and processing of a measuring campaign To open and view a measuring campaign file select the File Open menu item A first window that lets you select the desired measuring campaign directory is shown Deoa in 9 d p m 3 20050504 000 ENS50160 3 20050504 000 TRIGGER 9 20050530 000 MaNUAL 3 PHASE 0 20050601 000 4MP Nome fie File di Campagna srv we Double click on the desired campaign A second window is shown select the campaign file and press Open Nome 20050530 000 MANUAL 3 PHASE Api File di sr When opening program automatically recognises the type of measuring campaign selected Timed Transient or EN50160 and opportunely displays several windows with the views of the measurements and graphs 3 1 Timed Campaign As you can see the Main menu changes and takes on the structure described below al
51. ting reports filing and other important functions The program envisages only the OFF Line operating mode 1 it does not interact by communicating with the instrument In order to transfer the measuring campaigns you have to first remove the memory from JUPITER always remembering to turn off the instrument beforehand By using a proper external CF memory reader or a PCMCIA adaptor data can be copied onto the hard disk using the Copy Paste function of Windows Explorer It is also feasible to open the files directly from the CF The organisation and types of measuring campaigns will be looked at in detail farther on It is possible to analyse two or more campaigns at the same time The only limitation is the PC s computing power available memory and disk space The default language can be selected in real time by changing the international settings for the numbers currency date and time etc The program configures itself with the local international settings with the first execution 1 1 The main window The application presents the following first window POStudio File Options View Help wa See Bea 77272005 111326 Net Spa Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 5of 5 Vizzano 44 40044 Pontecchio Marconi Italy E Icontrol Tel 39 051 6782006 Fax 39 051 845544 2 http www elcontrol energy net sales elcontrol energ
52. tions without prior notice Page 35 of 35 Vizzano 44 40044 Pontecchio Marconi Italy Tel 39 051 6782006 39 051 845544 2 http www elcontrol energy net ener Y n el sales elcontrol energy net 5 3 The harmonic spectrum Elcantral Energy Met SpA 3 PHASE Pra studio recon TETIZE Spettro dalla 1a alla armonica L1 0 cor SDS TOS 15 07 17 100 1 Z 4 5 5 8 3 10 11 12 13 14 15 1 di 1 1 0 zi 22 Z3 24 25 26 23 X3 dd 1 OT Ted 2 3 4 5 6 8 1 11 12 14 14 1 16 1 18 1 0 z1 22 Z3 Z4 S 5 uz zm 23 __ __ __ ___ L0 Ll 0994 ___ 0055 002 2505 0493 ___ __ _ 00047 ______ ___ __ _ 24347 60 37 ___5 __ 0055 ______ ___5 _ Ld 494 00047 10051 __ _ 248 0015 ______ L 14 Ss4mv ______ ___15 __ _ 00455 ______ ____15 __ isemv __ __ 0045 00047 10051 ___ __ ___ 23 000
53. ual is subject to modifications without prior notice Page 22 of 22 Vizzano 44 40044 Pontecchio Marconi Italy P r 9 Tel 39 051 6782006 Fax 39 051 845544 2 http www elcontrol energy net sales elcontrol energy net energy net phase angle between 1 V2 l2 and 13 with the relevant indication of the type of load inductive or capacitive Lastly the unbalance of the three phase voltage system expressed in a percentage is displayed Values close to 0 indicate a balanced system Phasor lt 70050518 000 MANUAL 3PHASE gt V LIinbalance 0 3 3 1 8 Exporting the measurements into a text file You can export the data recorded in a measuring campaign into a text file which can later be imported by other data processing programs like Excel for example Select menu item File Export to start the export A window where you can set the export mode part or all of the measuring campaign and the export interval expressed in number of records Is displayed Measures export O Range From 1 Icontrol Energy Net POStudio Survey To export the entire campaign select and press Export If the other hand you want to export just a part select Interval set the first record number in the box From and last record number in the box To and then press Export use the grid view of the measurements in Excel style View Records to ide
54. wh abs wh abs varh ind varh ind ind Wh gen 1 1 Wh gen Wh gen varh cap varh cap varh cap Ah Vh avg FF avg PF avg gt 3 1 2 The THD measurements We can identify three boxes one for each phase giving the total harmonic distortion factor Total Harmonic Distortion Factor THD of the voltage signals THDV and of the current signals THDI compared to the fundamental and to the total rms value Consult the user s manual supplied with the instrument for more details THD 20050428 000 TIMING gt THD Li THD L2 THD L3 ref V ref V fnd ret V fnd 5 60 ELSE au ref rms 565 ref V rms 475 OM cin BESRE et lind 550 ref frd ref rms ref rms ref rns Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 12 of 12 Vizzano 44 40044 Pontecchio Marconi Italy Tel 39 051 6782006 Fax 39 051 845544 2 http www elcontrol energy net ener Y n el sales elcontrol energy net 3 1 3 The harmonic and interharmonic spectrums These windows one for each phase are made up of two sections placed side by side horizontally e section with the numeric display of the V and measurements and of the Cosphi value from the 1 to 31 harmonic in absolute and percentage value compared to the fundamental display of the percentage values and Cosphi are valid only for the classi
55. y net 5 9 EN50160 conformity frequency changes and voltage unbalance Elcontral Energy Met SpA ERST 60 50160 Certificato conformit Conformit EN50160 NON SUPERATA Oey um cer 100 stampata il 0672005 16 11 37 Pag 1 Er Frequeaza Li 12 L3 v L1 Wear ete Ame loue 2 v L3 SbIBiclame rip v Aline AT 91 IFE Zn c Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 42 of 42 Vizzano 44 40044 Pontecchio Marconi Italy E Icontrol Tel 39 051 6782006 Fax 39 051 845544 2 http www elcontrol energy net sales elcontrol energy net energy net 5 10 EN50160 conformity harmonic voltage Elcontral Energy Met SpA ERST 60 ENS0160 Certificato conformit Conformit EN50160 NON SUPERATA 2 J t 5 T 2 10 12 13 E 5 1 WT 19 2 stampata il OF 0672005 16 12 55 Pag 1 Er Rel User s Manual Rel PQS 0 2 This manual is subject to modifications without prior notice Page 43 of 43 Vizzano 44 40044 Pontecchio Marconi
56. y net energy net is made up of a title main menu and toolbars for quickly accessing the application s most important functions There is also a work area where the different windows with the instruments measurements graphs etc are displayed etc and a status bar with the system clock 1 2 The menu File operations associated with the opening printing and print preview of a measuring campaign file Options setting the default language View display selection of the different tool bars and status bar 2 display of the window with the program information and online help A series of icons depicting the tool bars are underneath the main menu They are divided into five types main view control measurement trend control recorder function record position harmonic spectrum mode and EN50160 The user can freely enable disable their display using the View command of the main menu lt is also possible to customise the position of each bar by proceeding as follows with the mouse point in the area adjacent to a toolbar s buttons and move the cursor with the left mouse button pressed The selected toolbar disengages from its original position and is dragged along with the cursor s movements the toolbar is drawn in the new position when the left mouse button is released The toolbar can be left fluctuating in a given point of the screen or can be once again hooked on to any one of the four borders of the main window Rel