Home
3000 Watt AC Inverter
Contents
1. Reason Solution Electrical interference from the inverter Add a ferrite data line filter on to the TV power cord PROBLEM Low battery alarm on all the time Reason Solution Input voltage below 10 5 volts Keep input voltage above 10 5 volts to maintain regulation Poor or weak battery condition Recharge or replace battery Inadequate power being delivered to the Use lower gauge wire inverter or excessive voltage drop Keep wire length as short as possible PROBLEM TV does not work Reason Solution TV does not turn on Contact TV manufacture to see if the TV is compatible with a modified sine wave 2008 Wagan Corporation All Rights Reserved Wagan and wagan com are trademarks used by Wagan Corporation 3000 Watt AC Inverter by Wagan Tech Specifications Name Description Input 12V 10 15V DC Output 115VAC Output waveform Modified Sine Waveform Continuous power 3 000 watts Surge power 6 000 watts Efficiency Approximately 90 No load Switch ON lt 0 6 ADC Switch OFF lt 0 2mADC Battery low alarm 10 5 0 5VDC Battery low shutdown 10 0 5VDC AC output sockets 2 US standard Power switch ON OFF control Dimensions 13 5in x Zin x 3 15in cm Net Weight 14 5 lbs kg Note All specifications are typical at nominal line half load and 77 F 25 C unless otherwise noted Specifications are subject to change wi
2. the full 10 hour run time It is important to add some extra battery capacity because as the batteries age they will lose Ah capacity Configurating The Battery Bank Six volt 220 Ah golf cart batteries were selected for these illustrations because they are generally readily available and relatively inexpensive They are deep cycle type and with regular recharging they have a relatively long life These batteries are flooded type they freely vent hydrogen and oxygen while under charging and heavy discharge They must be vented to outside air to prevent accumulation of explosive gases Battery Bank Diagram The diagram below shows inverter connections to a battery bank with recommended fuse protection Fe j INVERTER 6V 6V 6V 220Ah 220Ah 220Ah Safety Ground pA WAGAN www wagan com User s Manual Please read before using this equipment Fusing Requirements NOTE It is important that for this 3000 watt inverter has two ANL 300 ampere or equivalent main battery fuses be added to the positive battery cable as close as possible to the battery bank s positive terminal The fuse amperage rating must be sized to allow simultaneous operation of all the AC appliances to be powered allowing for the momentary high startup current requirements of inductive loads Use the recommended fuse block fuse holder and fuse or an electrical equivalent ANL type fuses and fuse holders
3. are readily available from marine supply dealers The fuses are very important to protect equipment batteries and personnel The fuses protect against battery explosion if the cables that connect to the inverter accidentally short READ AND COMPLY WITH THE WARNING BELOW EXPLODING BATTERIES CAN SPRAY MOLTEN LEAD HOT SULFURIC ACID AND OTHER METAL AND PLASTIC FRAGMENTS BATTERIES THAT ARE CHARGING OR UNDER HIGH DISCHARGE RATES PRODUCE EXPLOSIVE HYDROGEN GAS INTO THE SURROUNDING AREA BE SAFE FUSE THE BATTERY BANK AND MAKE SURE THE BATTERIES ARE PROPERLY VENTILATED DC Cable Gage Minimize cable losses by using the thickest wire available and the shortest practical length If the inverter and the battery are positioned within four feet of each other a minimum of 0 gage zero gage insulated copper wire should be used to make the connections If the distance is longer than 4 feet heavier wire will be required If insulated aluminum wire is used instead of copper wire 00 gage is a substitute for 0 gage copper wire Connecting The Inverter General information Loose connections will result in a severe voltage drop that can cause damage to connectors conductors and insulation and can cause sparking Reverse polarity connection will blow the fuses in the inverter and can permanently damage to the inverter Damage caused by reverse polarity will void the warranty Procedure 1 Make sure the cables are the proper gage and have the fu
4. hour rate In this example the user needs a one hour run time If the example battery is 220Ah 20 hour rate and the load is 220 amps that is 100 horizontal number of the Ah 20 hour rate Starting at the 100 horizontal point and looking up to the curve the results are that only 56 of the battery capacity is available This means that a higher battery capacity is required to get the desired run time one hour The curve also shows that a load of 200 of the 20 hour rate yields only 31 of the battery capacity The installer must carefully plan the capacity of battery bank or the run time may be seriously affected To the inexperienced installer several trial battery capacities may be required to make sure a large enough battery capacity is available to achieve the desired run time The curve can be applied to any lead acid battery under load providing that it has an Ah rating at the 20 hour rate 0 20 40 60 80 100 120140 160 180 200 2008 Wagan Corporation All Rights Reserved Wagan and wagan com are trademarks used by Wagan Corporation 3000 Watt AC Inverter by Wagan Tech Continuing with the previous example the 150 amp load will need to run for 10 hours so we begin configuration with a 1 500 Ah battery If the vertical is 1 500 and the horizontal is 150 amps the percentage of load on the battery is 10 The curve shows that the 1 500 Ah is derated to 90 of maximum This means that the battery will have to be 16 500 Ah for
5. maximum continuous wattage that the inverter has to supply 2 Estimate the number of hours the appliances will be in use between battery recharges This will vary depending on appliances For example a typical home use coffee maker draws 500 watts during its brew time of 5 minutes It maintains the temperature of the pot requiring 100 watts Typical use of a microwave oven is only for a few minutes Some longer operating time appliances are lamps TVs computers and refrigerator freezers 3 Determine the total watt hours of energy needed This is done by multiplying average power consumption in watts by hours of run time For example 1 500 watts for 10 hours 15 000 watt hours To get an estimate of the maximum current in amps that a battery bank must be capable of delivering to the inverter divide the load watts by ten For example a 1 500 watt appliance load will need 150 amps at 12 volts DC Using the 1 500 watts or 150 Amps for 10 hours example as above then 150 amps is needed for 10 hours This provides us with the basic amp hours Ah of battery that is required Ten hours at 150 amps equals 1 500 Amp hours Ah This answer is just a beginning because there are additional factors that determine actual run time These include AC appliance load and time in use basic Ah Cable gage and length cable losses Charge level of the batteries between use chargers have to be able to fully charge the batteries Tem
6. source including any AC power source Incorrect battery polarity will damage the inverter and void the warranty Keep this inverter in a dry environment Do not open the inverter there are no user serviceable parts inside WAGAN T E C TH www wagan com User s Manual Please read before using this equipment Load Considerations When an appliance with a motor starts it requires an momentary surge of power This surge of power is the starting load or peak load Once started the appliance requires less power to continue to operate This is known as the continuous load It is important to know the starting loads and the continuous loads of the appliances that are to be powered by the inverter Appliance power is rated in watts This information is usually stamped or printed on most appliances and equipment In some cases a tool will be rated in amperes To convert from amps to watts multiply Amps x 115 AC voltage Watts This formula yields an approximation of the continuous wattage load of that appliance The startup load of an appliance is a major factor of whether this inverter can power it Startup load is momentary With many appliances it is approximately twice the continuous load but some appliance startup loads can be as high as eight times the continuous load To determine if an appliance or tool will operate with this inverter run a test This inverter will automatically shut down
7. Determining Maximum Appliance Wattage Maximum AC appliance wattage is the first factor in planning battery and charging systems Some background Large microwave oven specifications list cooking power watts and appliance power Appliance power is the AC load the inverter has to supply Most other electrical tools appliances and audio video equipment have labels that list the unit s power requirements in watts If the tool or device is rated in amps multiply the amps by 115 115VAC to determine the watts For example a power tool rated at 4 amps will draw 460 watts Determine the wattage of each appliance you need to simultaneously operate Add all of the appliance wattages to obtain an estimated total watts number Remember to consider the startup surge that motorized appliances will cause Do not exceed the surge rating of this inverter 6 000 watts this can cause immediate overload shut down At 3 000 watts continuous output this inverter requires a DC power supply battery bank that can continuously supply 300 amps at 12VDC for the duration of the run time 2008 Wagan Corporation All Rights Reserved Wagan and wagan com are trademarks used by Wagan Corporation 3000 Watt AC Inverter by Wagan Tech Configuring The Battery Bank To determine the minimum battery ampere hour rating that you will need to operate appliances from the inverter and any DC appliances powered by the battery bank follow these steps 1 List the
8. Immediately turn off appliances if this occurs If the inverter experiences the following conditions it will automatically shut down Overheat Overload and Ground Fault leakage to sense circuit 4 WAGAN T E H www wagan com User s Manual Please read before using this equipment Over Temp LED Internal high speed cooling fans automatically turn on when the inverter requires additional cooling The inverter may overheat when it is being used in a location that does not allow adequate ventilation If the continuous power requirement of the appliance s being operated exceeds 3 000 watts the inverter will overheat The Over Temp LED will turn RED and the inverter will automatically shut down If this occurs turn OFF the inverter and determine the cause of the overheat condition before turning the inverter ON Digital Display The inverter is equipped with a digital LCD display to diagnose system operations if there are problems The display will continuously change every 20 seconds to show DC input voltage nominal 12 5VDC AC output voltage nominal 115VAC Watts delivered to the AC load DC voltage reading is the measurement of the voltage between the DC input terminals of the inverter not the actual battery voltage During high wattage applications the display may show a lower voltage level than the battery because of the voltage drop that occurs between the input cables and the battery This voltage drop shoul
9. TACHING OR REMOVING CABLES If the flooded lead acid batteries are used as examples given in this document be sure that periodic checks of battery electrolyte levels are accomplished Follow battery manufacturer s instructions in keeping the electrolytes at the proper level Be sure to use pure distilled water when replacing evaporated electrolyte liquid Aboard A Vessel Or Vehicle Manufacturer supplied engine driven alternators can usually be replaced with one that can continuously deliver higher amperage This should be done at the outset Keep the batteries 2008 Wagan Corporation All Rights Reserved Wagan and wagan com are trademarks used by Wagan Corporation 3000 Watt AC Inverter by Wagan Tech charging when the vessel or vehicle engine is operating In the case of a vessel make sure that shore power is used to recharge the batteries whenever possible Operating Issues Television and Audio Suggestions Although all inverters are shielded and filtered to minimize signal interference some interference with your television picture may be unavoidable especially with weak signals However here are some suggestions that may improve reception First make sure that the television antenna produces a clear signal under normal operating conditions i e at home plugged into a standard 110 120VAC wall outlet Also ensure that the antenna cable is properly shielded and of good quality Change the positions of the inver
10. an Corporation 3000 Watt AC Inverter by Wagan Tech Rear Panel Fuses are on the side of the inverter Ground Terminal Positive DC Negative DC Input Terminal Input Terminal High Speed Cooling Fans High Speed Cooling Fans The fans automatically operates when the internal temperature of the inverter requires additional cooling Negative DC Input and Positive DC Input Terminals Both the Negative and Positive DC terminals are insulated to protect from accidental short circuits 4 WAGAN T E C TH www wagan com User s Manual Please read before using this equipment Ground Terminal This connection is for connecting to a 6 gage insulated ground wire Do not directly connect this ground connection to the Negative DC terminal This is described in the installation procedure Fuse Covers Mounted on side panels of the inverter these Fuse Covers are for gaining access to fuses that protect circuits internal to the inverter Planning the Inverter System Any large wattage inverter system requires planning before installation There are several steps to the planning process so the user must determine the following Maximum inverter wattage required Operating time run time needed between battery recharges Battery bank capacity in amp hours Charger requirement to charge batteries within a practical time Distance between battery bank and inverter
11. arger battery bank is permissible to have two automatic battery chargers connected to the battery bank Regular Loss Of Commercial Power If the inverter system is used during commercial power outages that occur daily configure the charger system to replace energy during the time that commercial power is available Replacement of battery energy always requires more than was taken from the battery typically 130 In the example used earlier in this document the AC load ran for 10 hours If commercial power is available there are approximately 14 hours left in the day to do the recharging The following is an example of what is necessary to recharge a battery bank that has 16 500 Ah of capacity as in the example above and has been discharged to 10 5 volts discharged The charger has to replace 2 145 Ah 1650 x 1 3 Ah in 14 hours So the charger must charge at a rate of 153 Amps for 14 hours As this charge current is distributed among the batteries in the battery bank the current received by an individual battery is within its charge rating Be sure that the battery is well vented as the area will likely have accumulations of an explosive mixture of hydrogen and oxygen Follow all recommendations for use that are contained in the battery charger manual WARNING THERE IS DANGER OF EXPLOSION DO NOT CONNECT OR DISCONNECT CHARGER CABLES DIRECTLY AFTER BATTERY DISCHARGE OR RECHARGE MAKE SURE THAT THE BATTERY BANK AREA IS WELL VENTED BEFORE AT
12. ble end NOTE Connectors are not required to fasten cables to the inverter s Positive and Negative DC terminals The cable ends need to be stripped of insulation for approximately three quarters of an inch Be sure that the cable connector covers are on the cable so they can be reinstalled after the cables are connected Use a medium blade common screwdriver and loosen the cable connector screw Insert the Negative cable end into the terminal Tighten the screw to clamp the cable end Make sure you have a good secure connection Recheck and make sure the DC cable fuses are installed in the fuse holders CAUTION Making an initial connection between the positive cable and the inverter s positive terminal may cause a spark This is a normal and is a result of capacitors in the inverter starting to charge Because of the possibility of sparking it is extremely important that both the inverter and the battery bank be positioned away from any source of flammable fumes or gases Failure to heed this warning can result in fire or explosion Do not make the positive terminal connection immediately after the batteries have been charging Allow time for the battery gasses to vent to outside air Attach the positive cable end to the Positive DC connector on the inverter Make sure the connection is tight and secure Replace the connector covers and secure with the small retaining screws Turn ON 1 the inverter The display on the front pane
13. d not be excessive as this will seriously reduce run time This inverter will operate with an input voltage ranging from 11 to 15 Volts of direct current DC If the inverter input voltage level falls below 10 5 Volts DC an audible alarm will sound Should the voltage drop below 10 Volts DC the inverter will automatically shut down During charging from a generator solar panel or AC powered charger the battery voltage will be higher than when it is resting This inverter will shutdown if the input voltage is 15 Volts It will shut down automatically if this occurs However in some rare cases voltages greater than 15 may cause damage to the inverter Damage caused by excessive voltage input is not covered under warranty Two 115VAC Outlets Each outlet will supply 15 Amps 115VAC maximum for powering appliances Greater than 1 650 watts continuous power from an outlet may cause damage to the inverter and cause possible injury High Output AC Terminals There are three insulated terminals on the front panel of the inverter These terminals are for connecting 115 volt AC devices that require more than 15 amps to operate Other uses are for connection to distributed wiring that has multiple AC outlets Any wiring that is directly connected must be 10 gage or larger Facing the Front Panel terminals are Left Middle Right Neutral Hot Ground 2008 Wagan Corporation All Rights Reserved Wagan and wagan com are trademar
14. gA WAGAN Item no 20072 T EC H 3000 Watt AC Inverter User s Manual 3000 Watt AC Inverter by Wagan Tech Thank you for purchasing this 3000 Watt DC to AC Power Inverter by Wagan Tech With minimal care and proper treatment it will provide years of reliable service Carefully read understand and comply with all instructions before use Keep this manual for future reference About This Inverter This power inverter converts 12 volts direct current 12VDC to 115 volts alternating household current 115VAC It easily powers TV VCR combinations microwave ovens refrigerators and small air conditioners It also operates at highest efficiency up to 90 that results in longer running time and extended battery life compared to other inverters with this level of power output This inverter has the highest surge capability in its class Superior surge capability allows the inverter to start the most difficult motorized loads Advanced microprocessor controlled circuits run cooler and are more reliable than competing units General Instructions Keep the inverter away from any direct heat source or combustible materials Keep well ventilated this device generates heat Keep the inverter away from combustible gases Do not continuously operate any equipment over 3 000 watts This inverter is designed to operate from a 12 volt DC power source only Do not attempt to connect the inverter to any other power
15. in the event of an output overload so there is no danger of damaging either the inverter or the equipment When lit two LED indicators signal a reason why the inverter is shut down This inverter may not properly operate some appliances with either speed control features or dimmer controls Some appliance GFCI power cords will not operate properly while powered by this inverter Again the only way to be sure of proper operation is to try it If an appliance within the 3 000 watt range will not operate properly and the LED indicator turns ORANGE in color from GREEN it s likely that the inverter system does not have the required output to operate that appliance SAFETY WARNING THE INVERTER OUTPUT CAN BE LETHAL IMPROPER USE OF THIS INVERTER MAY RESULT IN PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE 2008 Wagan Corporation All Rights Reserved Wagan and wagan com are trademarks used by Wagan Corporation 3000 Watt AC Inverter by Wagan Tech Front Panel The Front Panel view shows the inverter s ON OFF Switch Indicators direct wiring High Current Terminals four AC Outlets and optional Remote Switch Connector LED Display Over Temp LED T REMOTE uf Remote ON OFF Overload ei LED Two 115V ON OFF Switch AC Outlets OUTPUT AC 115V 60Hz High Output Terminals ON OFF Switch This switch controls operation of the inverter Error LED Shutdown LED This indicator turns RED as the inverter shuts down
16. ks used by Wagan Corporation 3000 Watt AC Inverter by Wagan Tech Neutral and Ground are bonded inside the inverter to comply with the National Electric Code NEC requirement that any AC source must have a Neutral to Ground connection Remote On OFF Switch Connection An optional cable and switch assembly provides a convenient Remote On Off feature Contact your dealer for ordering information Power Inverter Output Waveform This inverter s AC output is a Modified Sine Wave MSW 115 volts AC The comparison of Modified Sine Wave and household AC is shown in the figure below Sine Wave Modified Sine Wave MSW This modified sine wave has a root mean square RMS voltage of 115 volts Most ordinary AC voltmeters are calibrated to read average voltage and assume that the AC waveform will be a pure sine wave These meters will not correctly read MSW voltage and will display about 20 to 30 volts too low Any multi meter identified as TRUE RMS will accurately read MSW correctly With this inverter however you can rely on the digital display for accurate AC readings Inverter Output Characteristics Sense Line The high output terminals and outlets of this inverter are wired differently from household wiring The ground connection the round connection on an outlet is a sense line that will shut down the inverter if a short circuit to ground occurs The two blade connections on an outlet are ho
17. l should show 10 5 to 15 volts depending on the voltage of the power source When the voltage reading does not fall within this range check the connections of the wires to the terminals on the power source and the inverter to make sure they are secure Also check the voltage of the power source Make certain that the Over Temp or Error LED Indicators are not lit Turn OFF 0 the inverter The Error and Over Temp LEDs may briefly flash This is normal The audible alarm may also sound a short chirp This is also normal When you have confirmed that the appliance to be operated is turned off plug the appliance into one of the two AC Outlets on the front panel of the inverter Turn the inverter on Turn the appliance on WAGAN T E C H www wagan com User s Manual Please read before using this equipment Note If an extension cord is used from the inverter to the appliance limit the extension cord length to 50 feet or less Make sure that the cord is properly rated to carry the appliance load Charging The Battery Bank It is not the purpose of this Inverter User s Guide to provide detailed information regarding battery charging systems However the user should try to augment any charging system with either wind power or solar power These can continue to operate during power outages and they also reduce recharge time If automatic AC powered battery chargers do not provide enough charging current for a l
18. nnection with the sale of our products There shall be no claims for defects or failure of performance or product failure under any theory of tort contract or commercial law including but not limited to negligence gross negligence strict liability breach of warranty and breach of contract Warranty Performance During the above one 1 Year warranty period a product with a defect will be replaced with a comparable model when the product is returned to WAGAN Corporation with an original store receipt The replacement product will be in warranty for the balance of the one 1 Year warranty period Updated August 2008 PAGAN www wagan com 2008 Wagan Corporation All Rights Reserved Wagan and wagan com are trademarks used by Wagan Corporation
19. perature of the batteries colder batteries provide fewer amps Age and condition of the batteries older batteries lose Ah capacity Compliance with turning off unnecessary AC loads Use of DC appliances and compliance with turning off unnecessary DC loads Derating The Battery Bank Most lead acid batteries have a rating expressed in amp hours Ah The most common rating of Ah is at the 20 hour rate NOTE Despite several internet explanations there is no relationship between Cold Cranking Amps CCA and Ampere Hours Ah For example if a 20 Ah battery is discharged at a 1 amp rate is will take 20 hours to discharge that battery The terms charged and discharged relate to actual battery voltage This means that the output voltage of a nominal 12 volt battery starts at 13 2 volts WAGAN T E C H www wagan com User s Manual Please read before using this equipment fully charged then drops to 10 6 volts discharged If the load on the battery causes the battery to discharge faster than the 20 hour rate the capacity Ah of the battery is measurably reduced derated Derating is a major run time factor The curve below can help to determine what the battery bank can deliver under load The results are used to estimate how much additional battery capacity is needed to achieve the desired run time The left vertical numbers of the curve represents percentage of the battery capacity at the 20
20. r RMA and return instructions Each item returned will require a separate RMA After you have received the RMA and the return instructions from WAGAN Corporation please follow the instructions and send the item with PREPAID SHIPPING along with all of the required documentation a complete explanation of the problem your name address and daytime phone number WAGAN Corporation will at its option replace or repair the defective part A Returned Merchandise Authorization number RMA is REQUIRED when sending in any defective item WAGAN Corporation is not responsible for any item s returned without an official Returned Merchandise Authorization number The item s must be returned with prepaid shipping WAGAN Corporation is not responsible for any shipping charges incurred in returning the item s back to the company for repair or replacement This warranty is void if the product has been damaged by accident in shipment unreasonable use misuse neglect improper service commercial use repairs by unauthorized personnel or other causes not arising out of defects in materials or workmanship This warranty is effective only if the product is purchased and operated in the USA and does not extend to any units which have been used in violation of written instructions furnished Warranty Disclaimers This warranty is in lieu of all warranties expressed or implied and no representative or person is authorized to assume any other liability in co
21. se holders as close to the battery bank s Positive terminal 2 Install the fuses in the Positive cables 3 Make sure the ON OFF switch located on the front panel of the inverter is in the OFF 0 position Disconnect any remote switch from the connector on the front panel 2008 Wagan Corporation All Rights Reserved Wagan and wagan com are trademarks used by Wagan Corporation 3000 Watt AC Inverter by Wagan Tech 10 Ll 13 14 15 Locate the Ground Lug Terminal at the rear of the inverter Connect an insulated 6 gage copper wire to the terminal The other end of the ground wire is connected to a proper grounding point Use the shortest practical length of wire Connect this wire to the chassis of your vehicle or to the grounding system in your boat In a city the ground wire can connect to a metal cold water pipe that goes underground In remote locations the ground wire can be connected to an earth ground This can be an attachment to a 6 foot long copper clad metal rod driven into the ground In the unlikely event of a short circuit operating the inverter without proper grounding can result in electrical shock Do not directly connect this ground wire to the Negative DC Terminal Remove the insulating DC Connector Covers by unscrewing the small metal retaining screws Set the screws aside Slide the insulating covers on the respective cables so the wide end of the cover is facing the near ca
22. t The sense line triggers shutdown if either hot terminal the two flat connections on an outlet has an electrical path to the sense line If this happens it is reasoned that there must be a short circuit to ground and the inverter will shut down The inverter s ERROR LED will light to indicate this shutdown condition The sense line can shut down the inverter with a leakage of 5 mA or less WAGAN T E C H www wagan com User s Manual Please read before using this equipment This sense line action is a safety function similar to GFCI However GFCI is a mechanical interruption not an electronic shut down GFCI and the sense line can activate with a leakage of 5 mA or less Automatic shutdown is an important safety feature especially in applications near water Note that some older appliance power cords or outlets may have the ground pin connected to the neutral connection This connection will keep the inverter in a shut down condition The appliance ground connection must be isolated from the neutral plug connection for the inverter to operate CAUTION CONNECTING THE SENSE LINE TO GROUND OR TO EITHER HOT TERMINAL WILL KEEP THE INVERTER IN A SHUTDOWN CONDITION Terminal and Outlet Diagram Ground Neutral Neutral ot Hot Ground Household Hot Hot Sense ot Hot Sense Inverter 2008 Wagan Corporation All Rights Reserved Wagan and wagan com are trademarks used by Wag
23. ter antenna cables and television power cord Isolate the television its power cord and antenna cables from the 12 volt power source by running an extension cord from the inverter to the television set Coil the television power cord or install a clamp on ferrite choke available from electronic parts suppliers Note Some inexpensive audio systems may have a slight buzzing sound when operated with the inverter This is caused by insufficient filtering in the audio system The only solution to this problem is to get a sound system with a higher quality power supply Troubleshooting PROBLEM Low or no output voltage Reason Solution Poor contact with battery terminals Clean terminals thoroughly Using incorrect type of voltmeter to test Use true RMS reading meter output voltage PROBLEM Inverter Shutdown Reason Solution Battery voltage below 10 volts Recharge or replace battery Equipment being operated draws too much Use a higher capacity inverter or do not use power this equipment gawaan www wagan com User s Manual Please read before using this equipment Reason Solution Inverter is too hot thermal shut down mode Allow inverter to cool Check for adequate ventilation Reduce the load on the inverter to rated continuous power output Unit may be defective See warranty and call customer service PROBLEM TV interference
24. thout notice Disposal Of Inverter Electronic products are known to contain materials that are toxic if improperly disposed Contact local authorities for disposal and recycling information pa WAGAN www wagan com VVSV6 VO piomADH 0 1di 5 1 s os ou Biuo eu Jo 4S eIueue T UPS B8OLE Ados p Im Buojo uuoj uolipiisiB ajajdwos eu row uollpiodioo NyOYM AJUDIIDM siy B DAYDD O spuoind Jo skop QE u UlHA BOIAIOS JOWOJSND UYY peieysiBel eq Isnui sionpoid Uo DIOdJOD NYOYM O W l l l lll lD ii s oe us ewpu 9104S Pf ie won sselppo IDu 7 epos diz eos Bulow N ce uw 2 5 x D Q D g 5 a E pm g o O lt lt dioS NVOVM 104 AJUDIHIDM papu AW IDAII9D sp d ra Detach and return left portion to the address above WAGAN Corp Limited Warranty All WAGAN Corporation products are warranted to the original purchaser of this product Warranty Duration This product is warranted to the original purchaser for a period of one 1 Year from the original purchase date to be free of defects in material and workmanship WAGAN Corporation disclaims any liability for consequential damages In no event will WAGAN Corporation be responsible for any amount of damages beyond the amount paid for the product at retail In the event of a defective item please contact WAGAN Corporation at 800 231 5806 to obtain a Returned Merchandise Authorization numbe
Download Pdf Manuals
Related Search
Related Contents
Motores MAX-40LA & 46LA MANUAL DE INSTRUÇÕES PDFファイル Supplément Integrated Lights Out Manager (ILOM) 3.0 Guía docente abreviada de la asignatura: Optimización I User`s Manual, PNC-2300A (English) Users` Manual automóvil guía de inicio rápido User`s Manual - Reliable Measuring Systems Copyright © All rights reserved.