1. pending upon the number of minutes avail able Scheduled Off PowerPanel Plus can be set to automatically shutdown the computer system at a user specified time scheduled off settings that are set to occur within seven days will be displayed Temperature This indicator displays the internal operating temperature of the unit If the temperature exceeds 158 F 70 C the indicator will change from green to red Load Level This indicator shows the of capacity of the battery outlets that is currently being used This indicator appears in green or gray but will turn red if the load ex ceed 90 Output Voltage This indicator shows the output voltage of the UPS Figure 2 Pow E zal Loa Schedule OP1000 2 300 Setup Model Version PowerPanel Plus Setup Window See Figure 3 UPS Self Test Allows the user to test the UPS without having to unplug the unit from the wall When Run is clicked the unit will switch to battery power and the unit will beep About This button will display information about the software as well as contact informa tion Advance This button opens the Advanced Setup Window Default Click this button to return the software to original factory settings Cancel This button exits the window with out saving changes OK This button exits the window and saves changes d Buzzer On yd Time between power failure and shutdown 30 sec ed Time between power failure an
2. Please contact CyberPower Systems Flash absence of AC power Electrical Wiring Fault This indicates a wiring a problem such as a bad ground missed ground or reversed wiring within the AC outlet User is Set Up None advised to disconnect all electrical equipment On Off from the outlet and have the outlet checked by an electrician CyberPower SPECIFICATIONS Input UPS Output AVR Max boost 12 of input voltage for output regulation while input voltage is from 10 to 30 Line Conditioning under nominal Regulation AVR buck 12 of input voltage for output regulation while input voltage is from 10 to 26 over nominal On Battery Output voltage 120 Vac 5 60HZ regulation 4ms typical including detection time On battery output Simulated Sine Wave Form wave form 1500VA 900W Full time Surge Protection Max Load 12 0 Amps Output Battery Battery type sealed Maintenance free lead acid battery Batteries Recharge Time 4 to 8 hours from total discharge Interface RS 232 and USB with Plug and Play interface Power On Electrical Wiring Fault AVR Using Battery LED Indicators Check Battery Output Recepta 3 Battery powered and full time surge protection cles 6 full time surge protection EXPECTED RUNTIME IN MINUTES Desktop PC with 15 Monitor 72 100 Desktop PC with 17 Monitor 56 80 Desktop PC with 21 Monitor 45 65 Tower PC with 21 Monitor 40 60 10 1500AVR HO G
3. outlet The battery is worn out Contact CyberPower Systems about replace ment batteries at tech cyberpowersystems com Mechanical problem Contact CyberPower Systems about at tech cyberpowersystems com Connect the serial cable to the UPS unit and an open serial port on the back of the computer You must use the cable that came with the unit The serial cable is not connected The serial cable is connected Check the back of the computer for an additional to the wrong port serial port Move the cable to this port The unit is not providing battery power Shutdown your computer and turn the UPS off Wait 10 seconds and turn the UPS back on This should reset the unit You must use the cable that was included with the unit for the software and the unit to be able to communicate The serial cable is not the cable that was provided with the unit 1500AVR HO Guaranteed Uninterruptible Power System DEFINITIONS FOR ILLUMINATED LED INDICATORS Xs lt A AVR Using Check Circuit Alarm Condition Fault Battery Battery Breaker PN E AVR is maintaining a consistent 120v level Flash 5 during a power sag eefe AVR AVR is maintaining a consistent 120v Onoff KAE least one piece of equipment from the UPS Wait 5 seconds reset the circuit breaker and turn the UPS on Overload Occurs in the Battery power Sup On Flas Lone plied Outlets Turn the UPS off and unplug at On Off On Off h Off On Off
4. than the three year limit CyberPower will as CyberPower elects as permitted by law repair replace 12 1500AVR HO Guaranteed Uninterruptible Power System or pay the Agreed Damage Amount defined below for the item s of your electronic equipment directly and properly connected to the product the Connected Equipment if that Connected Equipment is x damaged by AC power line transients spikes or surges on properly installed grounded and code compliant 120 volt power lines in the United States and Canada or by transients surges or spikes on standard telephone equipment lines or Base 10 100T Ethernet lines that are properly installed and connected a Power Disturbance and y is directly plugged into and properly connected to a Cyber Power Product in its original condition which is properly operated when a Power Disturbance passes through the CyberPower Product and y 1 exhausts the protection capacity of the CyberPower Product or y 2 damages the CyberPower Product This provision sets out the only liability of any character of CyberPower for direct indirect special consequential and or incidental damages under our Limited Warranty applies only to Connected Equipment and all such Liability is limited to the Agreed Damage Amount Making a Power Control Guarantee Claim To make a Warranty claim for damage to Connected Equipment under the Power Control Guarantee you must do the following 1 Complete and return t
5. that have previously been saved will be saved in their original location PowerPanel Plus is equipped with a Scheduled Shutdown feature that can automatically save and close open files and then shutdown the computer and UPS at a user specified date and time as well as start the computer at a user specified date and time Use of this feature is optional and is not required for the power failure shutdown to occur The use of the PowerPanel Plus software is optional The UPS unit will provide full surge suppression and battery backup without the software You must use the software if you wish to have the automatic shutdown feature Installation Guide Cyber Power UPS can provide surge suppression and battery backup without the software However if you need to schedule for UPS Auto shutdown then it is necessary to install the software Data Cable Optional Turn off your UPS Connect the serial interface cable to your UPS and the open serial port on the rear panel of the computer If you would like to use USB interface please connect the USB adapter with the Serial Cable then connect the USB to your computer See the figure 3 Plug the UPS into an AC outlet turn the UPS on and start your computer 4 Follow the instructions on the User s Manual to complete the installation For Windows 95 98 ME 1 Turn the UPS off and unplug it 2 Connect the serial interface cable to serial port on the UPS and an open serial port on the back o
6. auto assign names to any files that have not been previously saved and then save the file to the PCTemp folder which is located in the root directory of your C drive where C is the name of your main hard drive Once all open files have been saved and closed PowerPanel Plus will shut down the operating system Once the operating system is shutdown the UPS will turn off within 90 seconds Wait until the UPS has turned off before plugging the UPS back into the outlet Once the test has been completed plug the UPS back into the AC outlet and turn it back on You may then restart your computer Please allow 4 hours for the UPS to recharge before attempting another self test If you are not using PowerPanel Plus Have your computer and UPS turned on Unplug the UPS from the wall to simulate a power failure The UPS will begin beeping indicating a power failure Save and close any open files Shut down the operating system Once the computer system is shutdown turn the UPS off As the battery discharges the unit will beep more rapidly indicating that the battery is nearing discharge Once the test is complete plug the UPS back in to the AC outlet and start your computer Please allow 4 hours for the UPS to recharge before attempting an other self test O O EO D e REPLACING THE BATTERY CAUTION Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery Service the battery under the supervision of personnel k
7. for those item s You must return the product for inspection lf the damage to Connected Equipment is covered by the Power Control Guarantee CyberPower will in addition to Limited Warranty remedies for the CyberPower Product itself repair or pay the costs of repair or replace the Connected Equipment or at the option of CyberPower as permitted by law pay to the Initial Customer the Agreed Damage Amount up to the aggregate limits stated below for all item s of Initial Customer s Connected Equipment The Agreed Damage Amount for all items of Initial Customer s Connected Equipment shall be the lesser of the amount determined under Clause 1 or 2 below reduced by any amounts described in Clause 3 below 1 The fair market value of the Connected Equipment as established by the lower of a the average price the same or similar items are being sold for on E bay b the price list of Orion Blue Book on the date of occurrence or if such price list is no longer published a published or announced price list reasonably selected by CyberPower or c the lowest price the same or similar items can be purchased for in the United States or 2 The aggregate ceiling amount for all Connected Equipment CyberPower 1500AVR HO 40 000 00 13 CyberPower 3 The amount s of all payment you have or are entitled to receive from insurance other warranties extended warranties or from other sources or persons for the Connected Equipment or da
8. 1500AVR HO Guaranteed Uninterruptible Power System WHAT IS AVR This machine provides complete power protection open files and shutdown your computer system from utility power that is not always consistent during a utility power loss The CPS1500AVR HO features a high level of INCONSISTENT surge suppression 1500 Joules for power line Utility Power a Cyber Power surges and provides long lasting battery backup TAVR G with dual 9AH batteries for loss of utility power and T as oa ie voltage sags The CPS1500AVR HO ensures y as m consistent power to your computer system and 1 4 E E RA AA includes software that will automatically save your AUTOMATIC VOLTAGE REGULATOR The CPS1500AVR HO controls utility power voltage levels that can be inconsistent The incoming utility power may be at a damaging level to important data files but with the Automatic Voltage Regulation of the CPS1500AVR HO the computer will only experience a consistent voltage level An Automatic Voltage Regulator automatically increases low or decreases high voltage to a consistent computer safe 110v 120v The powerful dual 9AH batteries provide power only if the incoming voltage drops below 90v or increases above 145v DESCRIPTION 1500AVRHO 1 Power on Indicator This LED is illuminated when the utility condition is normal and the UPS outlets are providing clean power free of surges and spikes 2 Electrical Wiring Fault Indicato
9. 4 fo Event Closed Application Information Data Record UPS communication can t establish UPS communication established UPS communication cant establish UPS communication established UPS communication cant establish UPS communication cant establish UPS communication cant establish UPS communication established UPS communication can t establish 2NN3N198 NASS N4 LIPS communication cant establish 38 UPS communication established 40 UPS communication cant establish 7 uCancel 6 5 4 5 4 3 Figure 6 7 Closed Application Information Option Button When this option is selected the log will display the names and locations of any files that were auto saved by the software 1500AVR HO Guaranteed Uninterruptible Power System TESTING YOUR UPS SYSTEM Once you have set up your UPS system you may wish to test it Make sure that the UPS has been charged for at least 4 hours before performing this test If you are using PowerPanel Plus 1 With your UPS and computer on open an application such as notepad 2 Enter some data into the application 3 Unplug the UPS from the AC outlet When a power failure occurs PowerPanel Plus will appear on the screen The outlet and battery symbols will change to indicate a power failure The countdown timer will move towards zero When the timer reaches zero the software will begin to save and close any open applications The software will
10. Off Set Beep least one piece of equipment from the UPS Wait 5 seconds reset the circuit breaker and turn the UPS on 5 during a power surge Utility Failure The UPS is providing battery MiA power to the Battery Power Supplied outlets Utility Failure The UPS is providing battery Rapid power The rapid beeps indicate the battery will Off Set Beeps run out of charge within a few minutes Overload Occurs in the Full time Surge Pro tection Outlets Turn the UPS off and unplug at Off Up Overload Occurs in the Battery power Sup Loh plied Outlets Turn the UPS off and unplug at Off Up a least one piece of equipment from the UPS Wait p 5 seconds reset the circuit breaker and turn the UPS on Weak Battery Recharge the battery for at least On Flas 8 hours If Check Battery is illuminated contact On Off h Off On Set None CyberPower Systems for battery replacement information On Flas On Off On Off h Off Flash On Flas On Off On Off h Off Flash On Flas On Off gt h Off On Off Scheduled Turn on If the two battery indicators are flashing in rotation the UPS is waiting to turn on as configured in the schedule Cold Start Disabled If the two battery indicators Thr are flashing at the same time the cold start has Set Up in been disabled The UPS will not start in the Flash Set Up Surge Protection Malfunction Lightning in duced power line surge has damaged the surge Off Set Off protect function
11. appear as a blue and white battery icon located in the system tray near the clock PowerPanel Plus Icon PT start ASKER ERO 0 com Operating Instructions PowerPanel Plus Main Menu See Figure 1 1 2 3 Log Click on the log button to open the Log 7 Status Bar The area display messages Window about the status of the software Power Click on the power button will exitthe 8 Schedule Click this button to open the software window Schedule Window Minimize Button Click this button to mini mize the software Setup Click the setup button to open the Setup Window Model This shows the model of the Cyber Power UPS that is being used Version This shows the hardware version UPS OK PowerPanel Plus Main Window Description See Figure 2 Figure 1 4 Battery Level This indicator displays the current charge on the battery The indicator will display a red color when a power failure Occurs Input Voltage This reading shows the current input voltage of the utility power The input normally appears in green but will turn red if the input voltage is not operating nor mally Frequency This indicator displays the fre quency of the utility power Scheduled On PowerPanel Plus can be scheduled to turn your computer system on This indicator displays scheduled on settings that will occur in the next seven days Final Countdown When PowerPanel Plus detects that the utility voltage is no
12. d initial warning 10 jer SEC Iyd Delay between warning messages PowerPanel Plus Advanced Setup See Figure 4 5 CyberPower 1 Low Battery Voltage This sets the low battery cut off level The user can slightly ex tend the UPS run time by adjusting this set ting High Voltage Failure Sets the upper level where the UPS will switch to battery Low Voltage Failure Sets the lower level where the UPS will switch to battery Battery Mode Output Voltage Sets the voltage that the unit will output when running on battery Default defaults Cancel changes Restores the settings to the factory Exits the window without saving 7 OK Exits the windows and saves changes 8 Cold Start When enabled the UPS can start in the absence of AC power battery life it is recommended disabled To maximize to keep this li Low ca en a sume Mode 7 J 1 pl E Cold Start a 6 Ile Failure ua ii Voltage Failure a a Mode Output Voltage 4 OO p PowerPanel Plus Schedule Menu See Figure 5 1 2 5 6 7 Special Setting This setting allows you to schedule a one time startup shutdown Schedule Display This area displays the days dates and times of any scheduled start ups and shutdowns Turn On Select the day date and time that you want the computer system to restart Can only be used in conjunction with a scheduled shutdown Del
13. e applicable aggregate ceiling amount 3 The Power Control Guarantee does not cover damage to Connected Equipment or apply if the Product has been operated in a failure mode or not in compliance with CyberPower operating in structions and manuals or if the Connected Equipment has been operated in a failure mode or not in compliance with the instructions and manuals of its manufacturer vendor The Limited Warranty and the Power Control Guarantee Do Not Apply Unless The Initial Customer 1 Has properly connected the Product and the Connected Equipment to properly wired and grounded outlets including compliance with electrical and safety codes of the most current electrical code ANS NFPA 70 without the use of any adapters extension cords of other connectors 2 Has provided a suitable and proper environment for use and installation of the Product and Con nected Equipment 3 Has properly installed and operated the CyberPower Product and Connected equipment 4 Has operated the Product at all times within the limitations on the Product s VA capacity as stated in this User Manual CyberPower Does Not Cover or Undertake Any Liability in Any Event for Any of the Following 1 Loss of or damage to data records or software or the restoration of data or records or the rein Sstallation of software 2 Damage from causes other than AC Power Line Transients spikes or surges on properly in Stalled grounded and code compliant 120 volt power lin
14. ed by the Limited Warranty the Power Control Guarantee provides protection for damage to equipment connected to the Product Connected Equipment subject to certain terms and limitations The Power Control Guarantee is not first dollar coverage CyberPower s obligation is reduced by any amounts that Initial Customer is entitled to recover from other sources regarding the Connected Equip ment including insurance other warranty or extended warranty coverage whether or not the Initial Customer makes a claim for recovery including but not limited to a claim under any applicable insur ance other warranty or extended warranty The Limited Warranty does not cover Connected Equipment but as is explained below to be covered under the Power Control Guarantee the Connected Equipment must have been damaged due to a failure of the Product The Connected Equipment must have been damaged due to a defect in materials or workmanship of the Product In the event of damage to the Connected Equipment your exclusive remedy and CyberPower s sole obligations are as follows for Connected Equipment If a the Product purchased and owned by you is defective in material or workmanship b the Limited Warranty requirements have been met except that the three year limitation of the Limited Warranty does not limit the Power Control Guarantee which is for the lifetime of the Product and c none of the limitations or exclusions on warranty coverage apply or
15. es in the United States and Canada tran sients Surges or spikes on standard telephone land lines PBX telephone equipment lines or Base 10T Ethernet lines when properly installed and connected This exclusion applies for example to fluctuations in data transmission or reception by CATV or Therefore transmission or fluctuations or by transients in such transmission 14 1500AVR HO Guaranteed Uninterruptible Power System 3 Damage from any circumstance described as excluded above with respect to the product 4 Damages from fire flood wind rain rising water leakage or breakage of plumbing abuse mis use or alteration of either the product or the Connected Equipment Exclusion of Consequential and Other Damages The sole and exclusive remedies of the Initial Customer are those provided by the Limited Warranty and Power Control Guarantee CyberPower excludes any liability for personal injury under the Limited Warranty and Power Control Guarantee CyberPower excludes any liability for direct indirect special incidental or consequential damages whether for damage to or loss of property EXCEPT FOR AND ONLY FOR the specific limited agreement of CYBERPOWER to provide certain warranty benefits regarding Connected Equipment under the CYBERPOWER Power Control Guarantee loss of profits business interruption loss of information or data NOTE Some States or Provinces do not allow the exclusion or limitation of incidental or con
16. ete Delete the selected item from the schedule Add Adds an item to the schedule Cancel This button is used to exit the log window without saving any changes OK This button is used to exit the shutdown window and save any changes Please note You must click Add to add the item to the schedule 8 Turn Off Select the day date and time that you want the system to shutdown This is op tional to use and has no effect on whether your computer will shut down during a power failure 9 Weekly Setting Allow you to schedule a shutdown startup based on the day of the week 9 8 Taiyi Shutdown 1 amp Special Setting i Weekly Setting EEIE H r Turn Off Year Month 203 eS i 5 sea TE Hour Minute Ban On Eel KRIE PowerPanel Plus Log Menu See Figure 6 1 Event Option Button When this option is selected the log will display different Power Panel Plus events such as power failure program start and program end Log Display This area displays the informa tion as selected by the Event Closed Appli cation Information or Data Record option button Clear Clears the selected log Cancel Exits the screen without saving any changes OK Exits the screen and saves any changes Data Record Option Button When selected the log will display a record of the items that are shown in the main window such as in put output voltage and temperature Select Functior
17. f the computer Note You must use the serial cable that was supplied with the unit Plug the UPS into an AC outlet turn the UPS on and then start your computer Windows will find new hardware Insert the PowerPanel Plus disk into the floppy drive then follow the on screen instructions When the installation is completed remove the floppy disk Oe a a a For Windows NT Click on Start point to Settings and then click Control Panel Double click on the UPS Icon Remove the check mark from the box labeled UPS is installed on and Click OK Acknowledge the message that the UPS is in an unknown state Exit to the desktop then shutdown your computer Turn the UPS off and unplug it Connect the serial interface cable to serial port on the UPS and an open serial port on the back of the computer Note You must use the serial cable that was supplied with the unit 8 Plug the UPS into an AC outlet turn the UPS on and then start your computer 9 Click on Start point to Settings and then click Control Panel 10 Double click on Add Remove Programs NOOR 3 CyberPower 11 Insert the PowerPanel Plus disk into the floppy drive and then click Install 12 Follow the on screen instructions 13 When the installation is completed remove the floppy disk For Windows 2000 NOORONM 8 9 Click on Start point to Settings and then click Control Panel Double click on Power Options On the UPS Tab click Se
18. from the batterys Install the replacement battery by connecting the red wire to the positive terminal of the battery and connecting the black wire to the negative terminal of the battery Slide the battery back into the compartment 10 Replace the outlet cover and the 6 retaining screws 11 Recharge the unit for 4 8 hours to ensure the UPS performs expected runtime REMINDER Batteries are consider HAZARDOUS WASTE and must be disposed of properly Contact your local government for more information about proper disposal and recycling of batteries oe aS Sh 9 TROUBLE SHOOTING Full time surge protection outlets stop providing power to equipment The UPS does not perform expected runtime The UPS will not turn on PowerPanel Plus is inactive all icons are gray Circuit breaker has tripped due to an overload Turn the UPS off and unplug at least one piece of equipment Wait 10 seconds reset the circuit breaker by depressing the button and then turn the UPS on Battery not fully charged Recharge the battery by leaving the UPS plugged in Battery is slightly worn out Contact CyberPower Systems about replace ment batteries at tech cyberpowersystems com The on off switch is designed Turn the UPS off Wait 10 seconds and then to prevent damage by rapidly turn the UPS on turning it off and on The unit is not connected to The unit must be connected to a 110 120v 60Hz an AC outlet
19. he CyberPower Warranty card or provide reasonable proof of purchase for example a sales receipt that establishes you as the original end user consumer purchaser of the Product 2 Call CyberPower at 952 403 9500 or 877 297 6937 toll free write to CyberPower at 5555 12th Ave East Suite 110 Shakopee MN 55379 or e mail CyberPower at clains cyberpowersystems com within ten 10 days of the date of the event for which you wish to make a claim for warranty service 3 When you contact CyberPower identify the Product the Purchase Date and the item s of Con nected Equipment Have information on all applicable insurance or other resources of recov ery payment that are available to the Initial Customer and the name of the power utility supplier for the location of the Connected Equipment and Request a Return Materials Authorization RMA 4 Pack and ship the product to CyberPower and if requested the item s of Connected Equipment a repair cost estimate for the damage to the Connected Equipment and all claim forms that Cyber Power provides to you Show the RMA number on the shipping label or include it with the product Initial Customer shall prepay all shipping costs must pay the cost of the repair estimate and is responsible for packaging and shipment CyberPower s Duties CyberPower will inspect and examine the Product and the item s of Connected Equipment or at CyberPower s election your written statement and repair cost estimate
20. lect In the UPS Selection Dialog Box under Manufacturers click None Exit to the desktop and shutdown the computer Turn the UPS off and unplug it Connect the serial interface cable to the UPS and an open serial port on the back of the computer Note You must use the serial cable that was supplied with the unit Plug the UPS into an AC outlet turn the UPS on and then start your computer Windows will find new hardware 10 Insert the software disk into the floppy drive and follow the on screen instructions 11 When the installation is completed remove the floppy disk For Windows XP Home and Professional DAWN 00 NI Click on Start and then click on Control Panel Double click on Power Options then click on the UPS tab Set the manufacturer to None Exit to the desktop and shutdown your computer Turn the UPS off and unplug it Connect the serial interface cable to serial port on the UPS and an open serial port on the back of the computer Note You must use the serial cable that was supplied with the unit Plug the UPS into an AC outlet turn the UPS on and start your computer Windows will find new hardware Insert the PowerPanel Plus disk into the floppy drive 10 Follow the on screen instructions 11 When the installation is completed remove the floppy disk When the installation is completed the PowerPanel Plus software will appear on your screen for a few seconds and then minimize It will
21. m defects in material and workmanship for three years from the date of original purchase subject to the terms of this Limited Warranty Any Implied Warranty of Merchantability or for Fitness for a Particular Purpose if applicable to the Product is limited in duration to the period of ownership by the Initial Customer This provision shall NOT create any Implied Warranty or Merchantability or of Fitness for a Particular Purpose that would not otherwise apply to the Product NOTE Some States do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you To be covered you must still be the owner of the Product at the time of the failure that results in the claim made under this Limited Warranty 11 CyberPower Exclusive Remedies Under Limited Warranty Your exclusive remedy and CyberPower s sole obligations are as follows for the Product lf a the CyberPower Product you purchased and still own is defective in material or workmanship under this Limited Warranty or any applicable warranty imposed by law and b all Limited Warranty requirements have been met CyberPower will repair or replace the Product if it proves to be defective in material or workmanship during the Warranty Period Making a Limited Warranty Claim To make a Limited Warranty claim on a Product you must do the following 1 Complete and return the CyberPower Warranty Registration Card or provide reasonable proof of pu
22. mage to such equipment so that CyberPower s maximum liability shall be reduced to reflect all such other payments or sources of recovery lf CyberPower replaces the connected equipment or pays to the Initial Customer the Agreed Damage Amount the Initial Customer shall transfer all item s to CyberPower without warranty by the Initial Customer but free of lien or other interest CONDITIONS COMMON TO THE LIMITED WARRANTY AND THE POWER CONTROL GUARANTEE The Limited Warranty and the Power Control Guarantee are the only and the exclusive express war ranty of CyberPower with respect to the Product This exclusion of other express warranties applies to written and oral express warranties LIMITATION THE LIMITED WARRANTY AND THE POWER CONTROL GUARANTEE DO NOT COVER The Limited Warranty and the Power Control Guarantee are intended to exclusive rights and remedies and replace any other rights to the extent allowed by law 1 As to the CyberPower Product the limited warranty does not cover or apply to misuse modifica tion operation or storage outside environmental limits for the Products in transit in shipment or in storage damage or deterioration improper operation or maintenance or use with items or equip ment not designed or intended for use with the product 2 As to Connected Equipment the Power Control Guarantee covers only damage within the spe cific terms of the Power Control Guarantee to Connected Equipment and only up to th
23. n serial port on the computer If you are not going to use the software you do not need to con nect the cable 3 With the UPS unit off and unplugged connect your computer monitor and any externally powered data storage device Zip drive Jazz drive Tape drive etc into the battery power supplied outlets Plug your peripheral equipment printer scan ner speakers into the full time surge protection outlets DO NOT plug a laser printer copier space heater vacuum or other large electrical device into the UPS The power demands of these devices will overload and possibly damage the unit 4 To protect a fax telephone or modem line connect a telephone cable from the wall jack outlet to the in jack of the UPS Connect a telephone cable the out jack on the UPS with the CPU icon to the modem port of the computer The out jack with the telephone icon can be used to protect a tele phone or fax machine line 5 Plug the UPS into a 2 pole 3 wire grounding receptacle wall outlet Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical demands e g refrigerator copier etc Avoid using extension cords If used the extension cord must be rated for 15 amps 6 Depress the power switch to turn the unit on The power on indicator light will illuminate 7 If an overload is detected an audible alarm will sound and the unit will emit one long beep To correct this turn
24. nowledgeable of batteries and their precautions CAUTION Use only the specified type of battery See your dealer for replacement batteries CAUTION The battery may present risk of electrical shock Do not dispose of battery in a fire as it may explode Follow all local ordinances regarding proper disposal of batteries CAUTION Do not open or mutilate the batteries Released electrolyte is harmful to skin and eyes and may be toxic CAUTION A battery can present a high risk of short circuit current and electrical shock Take the following precautions before replacing the battery 1 Remove all watches rings or other metal objects 2 Only use tools with insulated handles 3 Do not lay tools or metal parts on top of battery or any terminals 4 Wear rubber gloves and boots 5 Determine if the battery is inadvertently grounded If inadvertently grounded remove source of ground CONTACT WITH GROUNDED BATTERY CAN RESULT IN ELECTRICAL SHOCK The likelihood of such shock will be reduced if such grounds are removed during installation and maintenance applicable to a UPS and a remote battery supply not having a grounded circuit wnerPower TO REPLACE THE BATTERYS Turn off and unplug all connected equipment Turn the UPS off and unplug it from the AC power source Turn the UPS upside down Remove the 6 retaining screws Turn the UPS right side up and remove the outlet cover Remove the batterys from the compartment Disconnect the battery wires
25. r This LED indicator will illuminate to warn the user that a wiring problem exits with the AC outlet such as bad ground miss ground or reversed wiring If this is illuminated the user is advised to discon nect all electrical equipment from the outlet and have an electrician check the outlet to insure proper wiring 3 AVR Indicator This LED indicates that the UPS is operating in automatic voltage regulation mode 4 Using Battery This illuminates during utility failure indicating that the battery is supplying power to the battery power supplied outlets 5 Check Battery This illuminates indicating a weak battery If the indicator is still illuminated after allowing the unit to charge for 12 hours replace the battery according to the instructions in the Replacing the Battery section of this manual 6 Power Switch can be used as a master on off switch for equipment connected to the battery power supplied outlets 7 All outlets Designed for AC Adapters Allows six AC power adapter blocks to be plugged into the UPS without making adjacent outlets inaccessible 8 Coaxial Cable Surge Protection Connect the coaxial cable from your cable antenna dish source to one of the surge protector s video connectors market IN With another section of coaxial cable connect the surge protectors corresponding video connector marked OUT to the appropriate jack on your tv vcr other device 9 Communication Protection Ports Communi cation pro
26. rchase for example a sales receipt that establishes you as the Initial Customer the original end user consumer purchaser of the Product and prove that the Product was purchased within three 3 years of the event for which you want to make a claim for warranty service 2 Call CyberPower at 952 403 9500 or 877 297 6937 toll free write to CyberPower at 5555 12th Ave East Suite 110 Shakopee MN 55379 or e mail CyberPower at clains cyberpowersystems com within ten 10 days of the event for which you want to make a claim 3 When you contact CyberPower identify the Product the Purchase Date and request Return Ma terials Authorization RMA information from CyberPower 4 Pack and ship the Product to CyberPower as instructed in your RMA Show the RMA code on the shipping label or include it with the Product You MUST prepay all shipping costs and you are responsible for packaging and shipment CyberPower will inspect and examine the Product within ten 10 days of receipt If the Product is not as warranted CyberPower will repair or replace the Product and return it to you at CyberPower s expense or if CyberPower is unable to or decides not to repair or replace the Product if defective within a reasonable time CyberPower will refund to you the full purchase price you paid for the Product pur chase receipt showing price paid is required POWER CONTROL GUARANTEE lf you are the Initial Purchaser and the Product is still cover
27. sequential damages so the above limitation may not apply to you DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT OR OTHER HIGH RISK ACTIVITIES CyberPower does not sell the Products for use in high risk activities The Product is not designed or intended for use in hazardous environments requiring fail safe performance including the operation of nuclear facilities aircraft navigation or communication systems air traffic control weapons systems life support or medical applications or for use in any circumstance in which the failure of the Product could lead directly to death personal injury or severe physical or property damage or that would affect operation or safety of any medical or life support device collectively High Risk Activities CyberPower expressly disclaims any express or implied warranty of fitness for High Risk Activities CyberPower does not authorize use of any of its products use in any High Risk Activities ANY SUCH USE IS IMPROPER AND IS A MISUSE OF CYBERPOWER PRODUCTS The Limited Warranty and the Power Control Guarantee are governed by the laws of the United States and the State of Minnesota without reference to conflict of law principles The application of the United Nations Convention of Contracts for the International Sale of Goods is ex pressly excluded Contact Information CyberPower s address is 5555 12th Ave East Suite 110 Shakopee MN 55379 and its phone number is 952 403 9500 or 877 297 6937
28. t operating normally the final countdown will begin When the countdown reaches zero Power Panel Plus will save and close any open files and then shut down the operating system in an intelligent and orderly manner Approximate Backup Time This indicator shows the approximate amount of backup time that is available based upon the battery ca pacity and the load on the system This indi cator can appear in red yellow or green de UPS is Installed On This shows the current port that the UPS is using The port assigned to the UPS needs to be used exclusively for the PowerPanel software Buzzer On This toggles the audible alarm on and off Play Sound Voice is being played when the UPS is turning on or facing a power outage Time between Power Failure and Shut down This is the user controllable delay be tween when the power fails and the software Starts the shutdown process If unchecked the unit will run on battery until the low battery signal is received 2 minutes of backup time remaining and then start the shutdown proc ess Time between Power Failure and Initial Warning This setting determines the delay between when the power fails and the first audible alarm Delay between Warning Messages User adjustable setting for the delay between the audible alarms that occur during a power fail ure 1500AVR HO Guaranteed Uninterruptible Power System T 8 9 10 T 8 10 11 12
29. tection ports will protect any standard modem fax machine or telephone 10 Serial Port to PC This port allows connection and communication from the DB 9 serial port on the computer to the UPS unit The UPS communicates its status to the PowerPanel Plus software This interface is also compatible with the UPS service provided by Windows 95 Windows 98 Windows Me Windows NT Windows 2000 Windows XP and Mac OS X 11 Full time Surge Protection Outlets All outlets on the unit provide surge suppression for con nected equipment 12 Re settable Circuit Breaker The circuit breaker provides circuit overload and fault protec tion 13 Battery Power Supplied Outlets Provides three batter supplied outlets for connected equip ment and insures temporary uninterrupted opera tion of your equipment during a power failure INSPECTION The box should contain the following 1 PowerPanel Plus software floppy disk 1 serial interface cable DB 9 1 serial to USB cable 1 telephone communication cable 1 user s manual 1 warranty registration card 1 UPS unit CyberPower HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 1 Make sure that the total Volt Amp VA re 3 If the power requirements of your equipment quirements of your computer monitor and pe are listed in units other than Volt Amps VA ripheral equipment does not exceed 1500VA convert Watts W or Amps A into VA by do 2 Insure that the equipment pl
30. the UPS off and unplug at least one piece of equipment from the battery power supplied outlets Wait 10 seconds Make sure the circuit breaker is depressed and then turn the UPS on 8 Your UPS is equipped with an auto charge feature When the UPS is plugged into an AC outlet the battery will automatically recharge 9 To maintain optimal battery charge leave the UPS plugged into an AC outlet at all times 10 To store your UPS for an extended period cover it and store with the battery fully charged Re charge the battery every three months to insure battery life POWERPANEL PLUS SOFTWARE INSTALLATION GUIDE 2 1500AVR HO Guaranteed Uninterruptible Power System Overview PowerPanel Plus is designed for use with Windows 95 Windows 98 Windows Me Windows NT Windows 2000 Windows XP and Mac OS X For Mac OS X software can be downloaded from www cyberpowersystems com downloads him The latest versions can be also downloaded from the website PowerPanel Plus works in conjunction with the UPS to provide full protection of valuable computer systems applications and data In the event of a power failure PowerPanel Plus automatically saves and closes open files under auto assigned file names or existing files names after software controlled delay The computer and UPS are automatically shutdown to conserve battery power Files with auto assigned names will be saved under C PCTemp where C is the name of your main hard drive Files
31. the terms of the Limited Warranty or the Power Control Guarantee or the State or Province may impose additional obligations or additional implied warranties To the extent necessary to comply with those laws the terms of the Limited Warranty and the Power Control Guarantee should be read to adjust to those requirements only to the extent necessary to comply with such local law lf you are an Initial Customer you are asked to read the following terms and conditions carefully before using the Product By using the Product you consent to be bound by and become a party to the Limited Warranty and Power Control Guarantee If you do not agree to the terms and conditions of the Limited Warranty and Power Control Guarantee you should return the Product for a full refund prior to using it REGISTRATION CyberPower requests that you complete and return the Warranty Registration Card enclosed with the Product or register the Product at its website www cyberpowersystems com to establish that you are the Initial Customer of the Product and therefore entitled coverage under the Limited Warranty and the Power Control Guarantee Registration is not required for Limited Warranty coverage but note if you do not complete a registration card you will be required to provide proof of purchase as described below to have the benefits of this Limited Warranty LIMITED WARRANTY CyberPower warrants to you the Initial Purchaser that the Product will be free fro
32. toll free CyberPower is the warrantor under this Limited Warranty You may also contact CyberPower on the Internet at www cyberpowersystems com 15
33. uaranteed Uninterruptible Power System Limited Warranty and Power Control Guarantee In purchasing CPS1500AVR HO in the United States or Canada the original end user receives a Limited Warranty and CyberPower s Power Control Guarantee from Cyber Power Systems USA Inc for ease of reading referred to as CyberPower The Limited Warranty and the Power Control Guar antee are intended to be the original end user s exclusive rights and remedies The Limited Warranty and the Power Control Guarantee are separate all though they are related Limited Warranty The original end user referred to as the Initial Customer receives an express limited warranty referred to as the Limited Warranty for the CPS1500AVR HO purchased from CyberPower referred to as the Product The Limited Warranty is for the Product itself The terms of the Limited Warranty are explained below Power Control Guarantee CyberPower also provides the Initial Customer with protection in the event that the Product is not free from defects in materials and workmanship and certain equipment con nected to the Product is damaged the Power Control Guarantee The Power Control Guarantee protects the Initial Customer for damage to equipment plugged into the Product The terms of the Power Control Guarantee are explained below The Limited Warranty and the Power Control Guarantee are subject to the terms set forth below Addi tionally State or Provincial law may adjust
34. ugged into the ing the calculations below Note The below three battery power supplied outlets does not equation only calculates the maximum amount exceed the UPS units rated capacity of VA that the equipment can use not what is 1500VA 900W for CPS1500AVR HO If typically used by the equipment at any one rated unit capacities are exceeded an over time Users should expect usage require load condition may occur and cause the UPS ments to be approximately 60 of below unit to shut down or the circuit breaker to trip value TO ESTIMATE POWER REQUIREMENTS Watts W x 1 67 VA or Amps A x 120 VA Add the totals up for all pieces of equipment and multiply this total by 6 to calculate actual require menis There are many factors that can affect the amount of power that your computer system will require The total load that you will be placing on the battery powered outlets should not exceed 80 of the unit s Capacity HARDWARE INSTALLATION GUIDE 1 Your new UPS may be used immediately upon receipt However recharging the battery for at least four hours is recommended to insure that the battery s maximum charge capacity is achieved Charge loss may occur during shipping and storage To recharge the battery simply leave the unit plugged into an AC outlet The unit will charge in both the on as well as the off position 2 If you wish to use the software connect the enclosed serial interface cable to the serial port on the UPS and an ope
Download Pdf Manuals
Related Search
Related Contents
Manual 3. 検体について 【用法・用量(操作方法)】 1. アルミパックの開封 2. ミント Manual de Instalação GreatCall Jitterbug Touch User Guide Silent 12000H - Accessoires véhicules de loisirs et plein-air d`information Extron electronic 26-613-XX User's Manual Instruction Manual Manuel d`instructions Manual de Digitus PCI Serial interface card Copyright © All rights reserved.