Home

User Manual - SenseWear

image

Contents

1. pm pme y pe I l uliu Figure 17 Typically session start and end times are too broad for annotation purposes For example an Armband may be worn for three hours but the wearer was only exercising for the last 40 minutes You can refine annotation start and end times from the Add Annotation window figure 17 The Timestamp feature is used for highlighting a specific event in a data file as if you were keeping a diary of the data collected time and corresponding activity For greater accuracy in your annotations when using an Armband use the Status button figure 18 located on your Armband The Armband must be on body for a Timestamp to register For example if the wearer wants to add an annotation for the time they exercise they would press the Status button as they begin to exercise and when they finish The software allows you to view in detail the specific time of each Timestamped event and to add annotations Gfeonvmenra Status Button Figure 18 15 Creating Reports The SenseWear Software and SenseWear Professional Software allows you to create a report of the data figure 19a To create a basic report follow these simple steps 1 Open the data file 2 Go to the View amp Annotate Data screen and select the time period you would like to see on the report 3 The report includes the subject and clinician information plus any recorded notes Change these values from the My Data Properties page The My Dat
2. Total Energy Expenditure Lying Down t 23212 kJ Sea an 1 day 4 hrs 34 min Sleep amp 21 hrs 28 min Average METs PAL 1 4 1 3 Sleep Efficiency C 75 Active Energy Expenditure 1 5 METs 8579 kJ Physical Activity Duration 1 5 METs 17 hrs 47 min Number of Steps Total Distance 16913 steps 14 2 km dy My Data Properties 44 Graph Generate Report C gt Expor X Close Data File Figure 6 The date and time located to the left and right just above the selector indicate the total duration of the data file Inside the rectangle itself the beginning of each day midnight within this duration is marked by the date and a thin vertical light grey line Solid colored areas show periods when the Armband was on body and when the Armband was collecting data Thin horizontal grey lines show periods when the Armband was off body and not collecting data The shorter blue vertical lines indicate that the Timestamp Status button was pressed figure 7 You can highlight different time periods within the entire duration of the collected data with the time selector To select only one day from the time selector click anywhere on the day you wish to view The selector will automatically select that day midnight to midnight To select multiple complete days click on the first day you would like to view and shift click on the final day you want displayed To select start and end times drag the time selectors below the horiz
3. Height 0 0 centimeters 0 0 Weight 0 0 kilograms BSA 0 0 m WHO RMR pr kcal n US customary units on the armband Close Apply Figure 27 22 TIP The subject data under the Subject Info tab must be complete before you can save the Display Settings The Display Settings tab figure 28 will be editable if a compatible armband is connected such as model MF This tab will allow you to set initial message targets average METs and time format for the optional SenseWear Display Please refer to the SenseWear Armband and Display Manual for proper usage In addition to configuring the Display the targets and average METs will be included on generated reports by default SenseWear Professional E x View Settings Recent Data Files Retrieve View amp Annotate Configure Armband Data Armband Data Armband amp Display Subject Info Display Settings Armband Parameters Data Channels Initial Message Important This message is used to i with the correct armband This message should be unique and recognizable by the wearer Set Targets ee eee Calories burned Optional Activity Display ii Minute of Vigorous Physical Activity Average METs Time Display Format Clear All Figure 28 IMPORTANT Be sure to enter a unique and recognizable message in the Initial Message field This allows you to confirm that the Display is correctly paired with the Armband The Armband Parameters tab fig
4. View Duration on body Start Time Tue May 18 2008 12 17 PM Wed May 20 2008 12 00 AM 11 hrs 43 min 11 hrs 40 min 99 696 Wed May 20 2009 12 00 AM Total Energy Expenditure Average METs Daty Avg Total Daily Avg 5023 5029 ouies 1 6 smy n EE Tue Tue Tue 30 METs 3 0 6 0 METs e jo P e 4124 steps 1655 pues 1 41 4124 L3 41 Annotation Key 1 SLEEP IN BED 2 EXERCISE ROAD BICYCLING 3 EXERCISE RUNNING 4 OPTIONAL OFFICE WORK 5 MOTORING PASSENGER Tue Physical Activity Duration Vigorous 3 0 METS 6 0 9 0 METS Dally Avg Tots Daty Avg Tots 1m4 min Omn 1 41 0 00 tat ES aoc Tue Tue Duration on body Daily Avg Total Daty Avg Total 11 rs 40 min 0 min 11 40 0 00 1140 icra ooo Tue Tue Partial Day Value is not representative of a 24 hour timeframe The information contained within this report is not to be used for diagnostic purposes The information contained within this report is not to be used for diagnostic purposes Figure 19a Figure 19b TIP To customize the reports go to the Reports tab under Application Preferences for additional options 16 Exporting Data The SenseWear Professional software allows you to export data in XLS or CSV format for Microsoft Excel and other data analysis applications Automatic Exporting of Data When data is retri
5. a Properties button is located in the bottom left of your screen figure 6 4 Click Generate Report to create a pdf report figure 19a SenseWear Professional software also allows you to create a report with more detail Figure 19b To create a more detailed report click the Graph button in the bottom left of your screen A window will open showing a graph of the data The current set of graphed data will be included in the detailed report Click the Data Chooser button to edit the data Go to the File menu from the toolbar at the top of the graph screen and select Generate Report from the drop down menu A report will be generated that includes a summary page followed by more detailed graphs and information on the succeeding pages mbi by mbi by SenseWear Report Created Thu Sep 30 2010 Page 10f2 D soov eots SenseWear Report Created Thu Sep 30 2010 Page 30f3 Or BODYMEDIA Hospital Organization Practice Department Clinician Physician Hospital Organization Practice Department Clinician Physician Subject Age Gender Weight Height Handed Smoker BMI Subject Age Gender Weight Handed Smoker 0124 Height BMI 0124 45 Male 142 0 Ibs 64 4 kg 5 10 178 cm Right No 20 33 45 Male 142 0 Ibs 64 4 kg 5 10 178 cm Right No 20 33 Duration on body 1 day 23 hrs 38 min 99 3 End Time Duration of View Fri May 22 2008 12 00 AM Start Time End Time Duration of
6. ble from sensewear bodymedia com Support SW User Guides IMPORTANT If you choose to use the export or SFTP Secure File Transfer Protocol functionality you do so at your own risk You are solely responsible for any disclosure of information resulting from use of this information Introduction Welcome to the BodyMedia SenseWear System The SenseWear System including the SenseWear Software allows you to retrieve and save physiological and lifestyle data collected by the SenseWear Armband Please read and follow these instructions before connecting the SenseWear Armband to your computer This manual explains the setup of the system step by step installing the software configuring the SenseWear Armband and collecting and retrieving data from the Armband Please read and follow these directions SenseWear Software To run the SenseWear Software or SenseWear Professional Software the minimum requirements for your PC are Pentium Ill or higher with at least 256 MB of RAM Windows XP Vista 7 32bit amp 64bit 8 64bit video resolution of 1024x768 or higher and a USB Universal Serial Bus port for the Armband connection To activate SenseWear Professional you will need to purchase the license key for an additional cost Please contact your distributor for details BodyMedia s SenseWear Professional Software e Retrieves and saves physiological and lifestyle data collected by the SenseWear Armband e Organizes graphs and exports it for fu
7. dca1 2005 03 11 cardio arn SD bidca1 2005 03 11 cardio2 arn 2 n Sensewear Data Files swd v Cancel Figure 5 IMPORTANT SenseWear Software and SenseWear Professional Software are designed to work with MF SenseWear WMS armbands MF SW BodyMedia armbands and their data files The software does not support other Armbands The software does support existing data files that were recorded with SenseWear Pro3 armbands On the View amp Annotate Armband Data screen figure 6 the total duration of the file and on body data collection times is indicated on the interactive time selector figure 7 on the upper right of your screen The bottom half of the screen is a summary of the Lifestyle Indicators and Health Indicators By default the Lifestyle Indicators tab will be selected displaying a summary of the derived Armband data for the entire duration of the collected data file Clicking on the Health Indicators tab will Display a graph of any available biometric data blood pressure blood glucose or weight that have been manually entered 5j SenseWear Professional Recent Data Files Armband Maintenance Help Retrieve View amp Annotate Armband Data Subject Emily D Emily D 2009 05 18 swd Show sessions and timestamps FRI 15 MAY 17 13 MON 18 MAY 14 42 SAT 18 MAY SUN 17 MAY MON 18 M amp Friday 15 May 2 Saturday 1 Sunday 17 May Monday 18 May 4 21 min Lifestyle Indicators Health Indicators
8. els Timezone You can define from 2 to 5 activity levels and SenseWear will display the amount of time spent at each level Select the number of levels to define Label Note The information entered here only a r A uit intormatbon for new data Tres s and then Application Preferences Figure 23b NOTE Information entered in Clinician Info METs and Activity Levels of Application Preferences window are the default settings and will be applied to all new data files If you 20 want to change the information in a currently open data file only click the My Data Properties button at the bottom of your screen My Data Properties Notes Activity Levels Timezone Subject Info Clinician Info Clinician Physidan Organization ractice Department pe Note The intormabon entered here only applies to the current data T the default information for new data fies select Settings trom the menu ba and then Application Preferences Cancel Figure 24 Reports The Reports tab allows you to customize the generated reports figure 25 Check or uncheck the boxes to control what data appears in the reports EC Preferences eg General Data File Configure data fi Clinician Info Activity Levels Select Report options When generating a report for multiple days ignore partial days i e first and last iv Always indude Health Indicators in summary reports if ava
9. eved from a device a swd data file is saved At this time the data can also be automatically exported this feature is set in the Settings Preferences menu A SenseWear Professional license key allows for detailed data to be automatically exported Otherwise summary information is exported Exporting Data Exporting detailed data requires a SenseWear Professional license key To export a data file go to the View amp Annotate Data screen figure 6 Click the Export button located at the bottom of your screen When prompted name and save the xls or csv file To view the exported file double click on the file The detailed xls file will include five tabs Data Subject Info Summary Clinician Info and Legend The Data tab contains detailed data samples including raw measures derived values Timestamps and annotations The Subject Info tab includes the Subject s body information The Summary tab includes a day by day breakdown of derived information The Clinician Info tab includes notes and pertinent information about the data file for the clinician The data exported from SenseWear Professional also contains Blood Pressure Blood Glucose and Weight tabs if the data were entered manually The Legend tab includes a key to values used in the Data tab Application Preferences Application Preferences allow you to control the behavior of certain SenseWear Software and SenseWear Professional features Go to the menu bar at the top of your sc
10. gure 15 Annotating the Data The SenseWear Software allows you to make annotations to a data file For example if the data shows a spike in physical activity you can add an annotation that describes what the wearer was doing for that specific time period Annotations can be added to data files from the View amp Annotate Data screen figure 6 Check the Show Sessions amp Timestamps box figure 16 A list of Session Start and End times as well as any Timestamps will appear in the window below Subject 0124 0124_2009_05_22 swd Lina coaccnne ann fmoctamnc iv show sessions and timestamps Session Start 12 17 Begin OPTIONAL OFFICE WORK Session End 17 01 ENG OPTIONAL OFFICE WORK Session Start 17 04 Timestamp 24a 17 36 Begin MOTORING PASSENGER Timestamp 2b Timestamp 2c 22 55 Begin SLEEP IN BED Wednesday 20 May Timestamp 2e 07 47 Begin EXER ROAD BICYCLING Time insert 08 35 Figure 16 The Session Start and End times demarcate periods when the device was continuously on body To annotate either an entire session or an event within the session click on the Session Start time and Shift click on the Session End time Then click the Add Annotation button above and to the right of the Sessions and Timestamps window A list of annotations will appear figure 17 Choose one from the list and click OK 14 cETC Re Ti m m m m JL LYIN un OPTIONAL_OFFICE_WORK M A
11. hat time figure 15 Cj Graph 06 23 2009 06 30 2009 o xX JUN 23 8 01 PM TUE JUN 30 12 08 AM WED JUN 24 THU JUN 25 FRIJUN26 SAT JUN 27 SUN JUN 28 MON JUN 29 ay June 24 June 25 04 34 AM Saturday Ju 7 04 34 AM Sunday Selected Time 01 day 03 hr 59 min 02 hr 55 min Tuesday June 30 01 00 AM 04 00 AM 07 00 AM 10 00 AM 01 00 PM 04 00 PM 07 00 PM 10 00 PM 01 00 AM 04 00 Ah Graph custom cr 5 Min Max Value Annotations Sleeping v Annotations ids Timestamps Motoring Walking v Activity Classifications Running Physical Activity 3 0 METs Elliptical Training Stationary Biking Bl Lying down Road Biking E Sleep Resistance Distance Eneray expenditure Step Counter Sensors if Ej Forward accel averi Total EE Active EE 3 0 METS Physical Activity 3 0 METS Ayerage METs Step Count Ave Spee Total Distance Lying Down Sleep includ ff bod 2 3664 kcal sso Y 4257 kcal 2 hrs 27 min 2 1 22369 13 4 miles 10hrs2min 8hrs 34 min estimate of 82 kcal Figure 15 13 Activity Classifications Activity Classifications can be selected in the data chooser This is a statistical analysis of the data that matches the recorded sensor patterns to activity Under steady state conditions the activity classifications indicate the activity from the set with the highest probability fi
12. icators window no changes will be applied to the data file until you click Save Changes After any type of edits you will receive a confirmation message after you select Save Clicking Cancel will undo any changes Keep in mind that manually entered data readings are subject to entry errors or typos Advanced Graphing of the Data The Graph button located on the bottom of the screen generates a detailed graph figure 11 of all the data collected and derived for the selected time frame Access to this feature requires a SenseWear Professional license key The values shown in the graph are approximate 10 Graph 19 05 2009 22 05 2009 Um File View Help iv Show sessions and timestamps WED 20 MAY THU 21 MAY Session Start 12 117 Begin OPTIONAL OFFICE WORK Session End 17 01 End OPTIOMAL OFFICE WORK Session Start 17 04 Timestamp 2a 17 36 Begin MOTORING PASSENGER Timestamp 2b 17 55 2 End MOTORING PASSENGER Timestamp 2c 22 55 Begin SLEEP IN BED Wednesday 20 May Timestamp 2d 06 23 2 Ene Timestamp 2e 07 47 G e Time insert 08 35 End EXERCISE ROAD BICYCLING Armband was worn 99 336 of the time 13 00 9 00 04 00 07 00 19 00 01 00 07 00 13 00 49 00 01 00 07 00 T T i iia i aia TT AM 1 a bl AP a Total EE Active EE 3 0 METs Physical Activity 3 0 METs Average METs Step Count Average Speed Total Distance Lying Down Sleep 36138 kJ Cre 40717 kJ 5 hrs 6 min 1 9 24870 6 1 kph 23 0 k
13. igure 30 Display Settings Armband Maintenance Help View amp Annotate Armband Data Configure Armband Parameters Forward accel peaks J Forward accel MAD iv Forward accel average v Forward accel point lv GSR average M Longitudinal accel peaks F Longitudir i Longitudinal accel a F Longitudinal accel point verage M Near body Temp average iv Proprietary ct R A Proprietary M Proprietary ct Iv Proprietar 4 A Proprietary channel 5 channel 2 v Proprietary channel 6 lv Proprietary channel 7 A Proprietary channel 8 MA Proprietary ct 19 iv Proprietary channel 10 iv Proprietary channel 11 Data collection duration estimate 0 days Armband amp Display Data Channels 1 Sample per min at 1 sample per min 1 sample per min at 32 sam ples per sec 1 sample per min 1 sample per min 1 Sample per min 1 Sample per min 32 samples persec 1 sample per min 1 sample per min at 1 sample per min 1 sample per min 1 Sample per min 1 sample per min 1 Sample per min at 1 sample per min 1 Sample per min 1 sample per min at 1 Sample per min 1 sample per min 3 hr 0 min Apply If you are not familiar with the low level physiological parameters the device collects we strongly recommend not changing this section If you need to clear memory from an Armband select Armband Maintenance figure 31 from the menu bar at the top of your screen and select the appro
14. ilable Alwave inchide data fram the Gence Wear dieniav in renorte ff availahle iv Always include data from the SenseWear display in reports if available Cancel Apply Figure 25 21 Using the Software to Configure an Armband and Display You can use the SenseWear Software or SenseWear Professional Software to personalize the Armband to a specific wearer to configure the data to be collected to configure the associated sampling rates and also configure the targets if you have the optional SenseWear Display To begin click Configure Armband amp Display figure 26 and after connecting the Armband via the USB cable click Retrieve Configuration 3 SenseWear Professional File View Recent Data Files Armband Maintenance Help Retrieve _m View amp Annotate Configure Armband Data Armband Data Armband amp Display To configure an armband connect it via the USB cable and click Retrieve Configuration Figure 26 From the first tab Subject Info figure 27 you will see the subject data if any is currently stored on the Armband To edit this information for a new wearer simply modify the fields and click Apply 3 SenseWear Professional File View Settings Recent Data Files Armband Maintenance Help Retrieve A View amp Annotate Configure Armband Data 2 Armband Data Armband amp Display Subject Info Display Settings Armband Parameters Data Channels Current Age Date of Birth Mae 1 BMI
15. lp Retrieve View amp Annotate Configure Armband Data Armband Data w Armband amp Display Figure 1 Connect the USB cable to the Armband and to one of your computer s USB ports Then click Retrieve Data to transfer data from the Armband to your PC A window will pop up figure 2 requesting you to enter a file name Enter a name and click Continue The data file will be saved in your default directory Case Conunue Figure 2 If you want to change the location of your default directory click Browse and select a new destination directory IMPORTANT After the Armband data has been successfully retrieved and saved to a data file the data is cleared If you want the data to remain on the Armband unselect the Clear Armband for next use checkbox before clicking Continue If the Armband was not configured prior to wearing you will receive a pop up window figure 3 after the data has been retrieved The window will prompt you to enter the wearer s Subject Info and other important information needed to derive accurate lifestyle information The subject information MUST be entered to ensure that the software can accurately analyze the raw data collected by the Armband See Step 2 Armband Configuration in the SenseWear Software section above Notes Timezone Subject Info Clinician Info In order to accurately interpret the data you are retrieving please specify the following body parameters of the wearer Q nar
16. m 21hrs 53 min 17 hrs 35 min estimate of 166 kJ Figure 11 To edit the time period selected use the time selector box at the top of your screen Edit the data and lifestyle information you want to see in the graph with the Data Chooser window figure 12 If the Data Chooser window does not open automatically click the Data Chooser button figure 13 on the left side of the window Check the box next to the menu items you wish to include in the graph figure 14 11 Thursday 25 June 06 19 12 21 Fridav 2 Sunday Monday Tuesday 30 June 07 00 08 00 09 00 Graph custom e Min Max Value Annotations Iv Annotations Max E Timestamps Activity Classifications Physical Activity 3 0 METs E Lying down a caa JE Energy expenditure Skin temp average Min Total EE Active EE 3 0 METs Physical Activity 3 0METs Average METs Step Count 1531 kcal 4e52fftoov 4403 kcal 1 hr 50 min estimate of 14 kcal Figure 12 Session Start 06 59 Time insert 09 00 Begin C 10 40 Session End 14 44 Session Start 14 4 05 47 d Annotations Figure 13 12 Graph custom Min Max Annotations Tiestarnps Iv Activity Classifications JE Physical Activity 1 5 METs Lying down Positioning the mouse over a graph line displays the time and positioning the mouse over an activity bar displays the duration and label of the activity at t
17. o sopymenre SenseWear User Manual SenseWear Software Version 8 BodyMedia SenseWear 8 0 Software Manual TABLE OF CONTENTS e Introduction 2 e SenseWear Software 2 e Retrieving Data to Your Computer 3 e Viewing and Analyzing the Data 5 e Viewing and Editing Health Indicators 8 e Advanced Graphing of the Data 10 e Annotating the Data 14 e Creating Reports 16 e Exporting Data 17 e Application Preferences 17 e Using the Software to Configure an Armband and Display 22 e Troubleshooting Information 26 IMPORTANT This product is not to be used as the sole basis for medical diagnosis care or treatment Read the entire SenseWear device Manual including the section on CAUTIONS before using the SenseWear system N WARNING Be careful not to over tighten the strap of the SenseWear Armband while on your arm If you feel constriction or loss of circulation at any time loosen the adjustable strap and readjust it to a more comfortable setting If you experience pain bruising swelling or discoloration of the arm discontinue use and consult a physician N CAUTION You must clean and disinfect the SenseWear Armband and Display before distributing them to a new user Information on how to properly clean and disinfect can be found in the Care Instructions section of the SenseWear Armband amp Display Manual CAUTION When giving an Armband to a user the SenseWear Quick Start Guide must also be provided Availa
18. ontal box You can then move the selected time period by dragging the bar between the widgets All values for these selected times will be automatically updated Click the Show Sessions and Timestamps checkbox under the Subject ID on the upper left of your screen for a chronological list of all on body sessions and Timestamps The list will appear in the window below the Subject ID Clicking on a specific day or time on the list will also highlight that item in the interactive time selector SUN 17 MAY MON 15 MAA Figure 7 TIP To select only one day from the interactive time selector Figure 7 simply position your mouse on top of the day you wish to view and click You can then drag the selected area to move this 24 hour time period Viewing and Editing Health Indicators The Health Indicators tab figure 8 will display all biometric readings within the date range of the data file These manually entered readings are displayed in the graph You can customize the graph by using the legend Clicking the arrow icon next to each reading type will reveal options to change the unit of measure used for that reading If there is no biometric data only Energy Expenditure will be graphed and displayed in the legend Lifestyle Indicators Health Indicators Figure 8 To add edit or delete a reading click on the Update Health Indicators button The Update Health Indicators figure 9 window will pop up with 3 tabs Blood Glucose Blood Press
19. or may not receive visual confirmation of the installation Double click the Armband icon on your desktop to open the SenseWear Software Click Configure Armband amp Display at the top of the screen Click Retrieve Configuration Enter the appropriate information in the Subject Info tab Click Apply at the bottom of the window Leave the Armband plugged in until the battery LED Light Emitting Display is blinking green to indicate a full charge 10 Detach the Armband from the USB cable o ON ou The Armband is now ready for data collection Reference the SenseWear Armband and Display Manual for instructions on how to wear the Armband Step 3 Data Retrieval 1 If using SenseWear Professional insert the license key into an available USB port on your computer before starting the software Double click the SenseWear icon on your desktop to open the SenseWear Software Click the Retrieve Armband Data button Click Retrieve Data Name and save your file np Wn Retrieving Data to Your Computer To start the program plug in the license key if you have one into a USB port and double click the SenseWear icon on your desktop The main screen figure 1 will appear as shown There are three buttons at the top under the menu bar Retrieve Armband Data View amp Annotate Armband Data and Configure Armband amp Display Retrieve Armband Data will already be selected File View Settings Recent Data Files Armband Maintenance He
20. port data Cancel Apply be Figure 21 Clinician Info In this tab figure 22 enter information specific to the clinician and organization that manages all data files Preferences E General Data File Clinician Info Activity Levels 3j Configure data file r spital Organization Cancel Apply eaae Figure 22 METs SenseWear Software only From the METs tab figure 23a you can set the threshold value used for determining physical activity C My Data Properties Subject Info Clinician Info Notes METs Timezone You can customize the METs level for the physical activity detection algorithm The default is 3 0 METs MFT the r Se a Vm imne current Cai e set u uais om t Note The information entered here only 30D applies t the default information for new data files select Settings from the menu bar and then Application Preferences Cancel Figure 23a Activity Levels SenseWear Professional only You can specify from two to five Activity Levels and SenseWear Professional will determine the amount of time spent at each level figure 23b An Activity Level is simply a METs range defined by an upper and lower value Note the upper value of the first Activity Level 1 5 METs when using the default settings is also used as the threshold value for determining physical activity C My Data Properties Subject Info Clinician Info Notes Activity Lev
21. priate command from the list Settings Recent Data Files Armband Maintenance onfigure Armband Data mband amp Display Clear Data amp Subject Info Figure 31 IMPORTANT Do not select Reboot Armband unless instructed to do so by a BodyMedia representative or your Technical Support Specialist Unnecessary reboots of the device can result in data loss Troubleshooting Information For troubleshooting information please visit sensewear bodymedia com 26 a 5 eobvMeptR BodyMedia Inc One Gateway Center 420 Fort Duquesne Blvd Suite 1900 Pittsburgh PA 15222 USA www bodymedia com e ver Emergo Europe Molenstraat 15 2513 BH The Hague The N therande 201 Sussex Street Sydney NSW 2000 Australia Asia Pacific Authorized Representative Emergo Asia Pacific Level 20 Tower II Darling Park CE 0086 Copyright 2014 BodyMedia Inc 2014 03 17 EN
22. reen Click Settings and select Application Preferences from the drop down menu A window will appear with the following five tabs General The General tab figure 20 allows you to select how date time height and weight values should be displayed and entered and how energy expenditure values should be displayed When selecting how the energy expenditure value is displayed you can choose to include or exclude off body estimates in the total energy expenditure results 17 Clinician Info Activity Levels Reports General Data File estimate of 655 kcal Figure 20 TIP Accurate energy expenditure values can only be calculated for periods when the Armband is worn on body The SenseWear Software includes an estimate of energy expenditure while the Armband is off body By default the option to include off body estimate is selected in the General tab This feature is most effective when off body periods are short and sedentary and the energy expenditure is approximately 1 0 METs Data File The Data File tab figure 21 allows you to customize the format for naming the data file when retrieving data from the Armband 18 Preferences w Clinician Info Activity Levels Reports General Data File lefault filename format for SenseWear Data Files YYYY DE M M um ubje cp YYYY SubjectiD bjectiD YYYY DD MM mE T LJ LIL MIN AS gs SubjectiD DD MM YYYY dformat JQP 2013 06 20 swd J Automatically ex
23. rther analysis e Offers an extra level of customization to configure the data collection channels of an Armband and the criteria used for Activity Level reporting In order to ensure proper data retrieval please read and follow these instructions before connecting the SenseWear Armband to your computer Step 1 Installation 1 Download the SenseWear Software from sensewear bodymedia com 2 Runthe downloaded installer program 3 Afterafew seconds the installation wizard appears Follow the instructions on your screen 4 Before starting SenseWear Professional insert the license key into an available USB port on your computer Windows will detect the new hardware and load the appropriate drivers You may or may not see a visual confirmation it depends on your version of Windows During installation you may receive a pop up window indicating that you do not have the proper authorizations to install this product If you receive this message contact your Administrator or IT Department for assistance Step 2 Armband Configuration Follow this procedure to configure the Armband before wearing it 1 Before starting the software insert the license key into an available USB port on your computer 2 Plug the USB cable into an available USB port on your computer 3 Plugthe opposite end of the USB cable into the Armband Windows will detect the new hardware and load the appropriate drivers Depending upon your version of Windows you may
24. t 3LUDJect Mata aE Dirt Date oT oru Figure 3 The software will display a message that you have successfully retrieved data in a pop up window figure 4 The retrieved data will be displayed automatically Figure 4 Viewing amp Analyzing the Data Data from the Armband will immediately be displayed after it is retrieved If you would like to view a previously saved data file choose Open Data File or go to File on your menu bar and select Open Data File A window figure 5 will open up to your default directory Double click on the data file you wish to open D bidad1_2005_02_17_cardio2_armband swd D bidad1_2005_02_28_weights1_armband swd D bidad1 2005 02 28 weights2 armband swd CD bidad1 2005 03 03 circuitl armband swd mi bidad1 2005 03 03 circuit2 armband swd D bidall_2005 02 24 cardiol_armband swd d bidall 2005 02 24 cardio2 armband swd D bidal1 2005 02 25 weightsl armband swd CJ bidal1 2005 02 25 weights2 armband swd D bidall_2005 02 28 circuitl_armband swd SD bidal1 2005 02 28 circuit2 armband swd oD bidat1 2005 03 04 cardiol_armband swd SD bidat1 2005 03 04 cardio2 arrr SD bidat1 2005 03 09 weights ar SD bidat1 2005 03 09 weights2 ar a bidat1 2005 03 11 circuitl arrr D bidat1_2005_03_11_circuit2_arrr D bidbr1_2005_03_04 cardiol_arrr CD bidbr1 2005 03 04 cardio2 arm a bidbr1 2005 03 07 weights ar SD bidbr1 2005 03 07 weights2 ar CI bidbr1 2005 03 10 circuit arm a bidbr1 2005 03 10 circuit2 arr SD bi
25. ure 29 allows you to verify the date and time of the Armband clock It also allows you to check the hardware version serial number battery level and memory capacity 23 SenseWear Professional Settings Recent Data Files Armband Maintenance Help Retrieve View amp Annotate Configure Armband Data Armband Data Armband amp Display Subject Info Display Settings Armband Parameters Data Channels 21 Jun 2015 Firmware Version Serial Number Battery Life Available memory Epo ch Timezone Offset GMT 4 00 Figure 29 IMPORTANT If you have an Armband and it is not synchronized with your PC clock a message may suggest that you synchronize the clocks If your PC clock time is the correct time we recommend doing this by clicking the Apply button IMPORTANT If using the optional SenseWear Display be sure to have your PC clock set with the same time zone of the location you will be using the Display Because data is displayed in 24 hour increments this will ensure the accuracy of the data Please refer to the SenseWear Device Manual for proper usage The SenseWear Professional software includes the Data Channels tab feature figure 30 This tab lets you configure the data channels to be collected and the sampling rates used by each channel 24 3 SenseWear Professional Recent Data Files Retrieve Armband Data Subject Info High Rat SE Den un a Research je Custom Channel Configuration F
26. ure and Weight Select the tab of the reading type you wish to update C Update Health Indicators Blood Glucose Blood Pressure JE 3 04 2008 07 00 105 mg dL E 29 04 2008 12 00 110 mg aL Jf 23 04 2008 20 00 120 mg dL JIT 30 04 9008 100 ma di JUI TI UO LUY Jur Cancel Figure 9 To manually enter a new reading click on the Add button A pop up window will appear for you to enter date time and a reading You can also select a unit of measure for blood glucose and weight Keep in mind that each type of reading must have the same unit of measure and can only be changed if there are no existing readings To edit select the biometric reading by clicking anywhere in the row of the reading you wish to change and click Edit The Edit window figure 10 will appear with the date time and reading in editable fields Once editing is complete click Save Changes and then Save Blood glucose readinas must be in the range i 17 Mau WING 12 i2 May ZUU6 Us Time Reading save Changes Cancel Figure 10 To delete a reading click anywhere in the row of the reading you wish to remove and click Delete A confirmation message will appear To remove more than one reading at a time hold down the Shift or Control key to select additional readings Clicking OK will apply all changes to the data file and update the health indicator graph TIP Although all updates will appear in the Update Health Ind

Download Pdf Manuals

image

Related Search

Related Contents

Guide méthodologique  Samsung BCD-183E 用户手册  Modulated Speed Rotator User Manual  Prolongación del mango HVLP Extensão do manípulo  TURBINE FLOWMETER - Hoffer Flow Controls, Inc  Soleus Air HR1-08R-21 User's Manual  Utilidades - OKI Support  FS4438 DPv1.2 State Analysis Probe User Manual    SYNCRON - Prodance  

Copyright © All rights reserved.
Failed to retrieve file