Home

BIOSTORE - Telenet Service

image

Contents

1. 630 630 82 94 1470 Bes 5 3 10 1 210 157 60 720 1565 CONSTRUCTION Austenitic stainless or white plasticized sheet exterior casing sides front panel door Austenitic stainless interior lining Back top and bottom of the exterior casing in corrosion proof galvanized sheet Austenitic stainless door liner Insulated body Monocoque type Radiused interior Polyurethane foam insulation 60mm thick Thermal break between inner and outer structure 5 adjustable legs or optional casters Anti condensation door frame heater freezing model Plain door Easily removable magnetic door seal Door with security lock 90 hold and self closing door TECHNICAL DATA Voltage 1 230V 50 Cycle Chilling Freezing Input power 700 W 1170 W Protection A aM 6 Delivered with a moulded plug The installer is responsible for protecting the appliance against overloads or electrical defects Ensure a circuit breaker or fuses are installed Chilling Freezing Refr power 555 W 750 W at 15 55 C at 30 55 Refrigerant R404A R404A Load See appliance instruction plate Compressor Hermetic Condenser Forced air Evaporator Ventilated double flow corrosion proof chilling model Ventilated for freezing
2. Mark logos Electric panel Electronic thermostat Profile end VT T 4 Lock pin Door switch Lighting D ee 4 Control panel switch fixing screws Instructions n 648270 Page 12 5 ELECTRICAL DIAGRAMS 5 1 CHILLING CABINETS N SE133 PRINCIPLE DIAGRAM M A On Off switch Tr transfo Th Thermostat Sd Probe Cp Compressor Vc Condenser fan Ve Evaporator fan Rev Evaporation heater IP Door switch for lighting according to model Lp Lighting lamp according to model CONNECTING DIAGRAM Instructions n 648270 Page 13 5 2 FREEZING CABINETS N SE135 PRINCIPLE DIAGRAM M A On Off switch Li Shunt between 7 and 2 on 1 door models e 4 2 Tr Transfo Th Thermostat Sd Probes KMgr Compressor contactor Vc Condenser fan Rd Defrost heater Re Flow heater Ve Evaporator fan IP Door switch according to model Lp Lighting lamp according to model Rp Door heater Cp Compressor Rev Evaporation heater 11915 1 T EZ TL Thermostat Instructions n 648270 Page 14 5 3 TWIN DOOR CABINETS N SE241 PRINCIPLE DIAGRAM M A h On Off switch Tr Transfo Th Thermostat SdA h upper temperature prob
3. 58 MFE2 cap evaporator housing S010PC58 MFE2 T E V evaporator housing So10PB58 MFES cap evaporator housing So10PD58 MFES T E V evaporator housing e S010PG58 MFE2 cap evaporator housing S010PH58 MFE2 T E V evaporator housing e e seseP70 Capilary 12 10 length 2 5 m 977 70 capilary 10 10 length 2 m wi NM MEN NI Er Ec p S980P70 Capilary 12 10 length 3m S978P70 Capilary 10 10 length 3 m e S972P70 Capilary 8 10 length 2 m e S157P15 33 10W evaporator fan e S158P15 evaporator fan S327P46 double flow evap housing cover e 8058 11 MF2 MFE2 evapo unit casing 5 059 11 MFES evaporator unit casing Instructions n 648270 Page 19 REFRIGERATING AND ELECTRIC EQUIPMENT 2 PART Toan a e a a 2x300 2x300 S140P15 MFE2 defrost heater SSS ae MFES defrost heater o e 8214P15 Flow heater _ e e e e S048P12 PVC flexible flow bend EE PVC fixed flow bend e so4P12 PVC flexible flow tube S200P11 Hot gas defrost water re evaporation tray e option option option option S330P11 Electric defrost water re evaporation tra n S142P15 PTC 12x180 heater cartridge F Pressure relief valve Ecc AERE mU HER 33 W door heater cable Teka oia
4. e S043PR58 insulated stainless door e 5043 558 Insulated white top 1 2 door e e e S043PTS8 Insulated white bottom v2 door e S048PUSS Insulated s s top Yedoor e S043PV58 Insulated s s bottom 1 2 door LL e e S043PW58 Insulated s s top 1 2 door LL e e S043PX58 Insulated s s bottom 1 2door e S043PY58 Insulated white glass door _ e s043PZ58 insulated s s glass door Instructions n 648270 Page 17 CASING 2 PART SR SRB SR SRB SN SNB SN SNB SRR SRN CODE DESIGNATION 600 1300 600 1300 2x300 2X300 e e e e S122P01 door handle e e e e S123P01 Aluminium front profile e S124P01 E door handle top R or bottom e S126P01 TT profile for 1 2 doors e e e e s127P01 Door handle plugs e e e e s128P01 Front profile plugs e e e S408Pt1 PVC door handle cover e e e e S404pt1 PVC door handle cover Use e S384P11 PVC profile impression cover e e e S405P11 PVC front profile cover Eai a sos e Control panel label with logo Ur aja Nga a NE NZ lt ee Control panel label without logo BEE BONNET label 7 a Door magnetic seal e e e S401P11 Haf doormagneti seal ET Hat door magnetic seal E
5. Catchment container on the rear of the cabinet with automatic hot gas re evaporation Defrost water Complies with Electric safety Food hygiene EN 60 335 1 XP U 60 010 Complies with E C requirements lt Instructions n 648270 Page 4 1 3 SRR 2x300 and SRN 2x300 1 3 1 SRR 2x300 CONSTRUCTION H ni Austenitic stainless exterior casing sides front panel door 30 m Austenitic stainless interior lining 7 Back top and bottom of the exterior casing in corrosion 8 z proof galvanized sheet Austenitic stainless door liner Insulated body Monocoque type Radiused interior Polyurethane foam insulation 60mm thick Thermal break between inner and outer structure 4 adjustable legs or optional casters Anti condensation door frame heater freezing model 99 6855 1990 1590 685 5 Plain door Easily removable magnetic door seal Door with security lock 600 90 hold and self closing door eer I1 210 d 150 90 540 90 94 60 TECHNICAL DATA Voltage 1 230V 50 Cycle Chilling Freezing p Input power 700 W 1000 W Protection aM 4 aM 6 Delivered with a moulded plug The installer is responsible for protecting the appliance against overloads or electrical defects Ensure a circuit
6. lower lighting door switch SdA b lower temperature probe SdE b lower evaporator probe Rev evaporation heater Instructions n 648270 Page 16 6 SPARE PARTS 6 1 CASING SR SRB SR SRB SN SNB SN SNB SRR SRN CODE DESIGNATION 600 1300 600 1300 2x300 2X300 e e e e e e S070PO2 black plastic stand e e e e S359PM46 stainless steelfrontside e e e e S359PN46 Wnitefrontside l e e e S079PM42 siiffener 1 door galva front e S079PN42 stiffener 2 doors galva front e e e S079PO42 Stainless 1 door stiffener front J e S079PP42 Stainless 2 doors stiffener tront e S360PM46 Stainless 1 door control panel l e S860PN46 White 1 door control panel e S361PM46 Stainless 2 door control panel e S361PN46 White 2 door control panel e e S362PM46 control panel l e S880PM46 1 door s s control panel printer e S380PN46 1 D white control panel printer e S881PM46 2 door s s control panel printer e e SS81PN46 2 D white control panel printer I BCEE gt l e e S352P46 Central slides support LL e e s227P42 Slides support e e e e soi9P02 slides supportaxs LL e e S009Po2 Slides support axis SE sme e nn een e e
7. 1 S216P15 42 W half door heater cable PEPPER WE eee eee e e 15093 20 Freezer thermostat 809420 Fridge thermostat ILL e Le S188P20 Duo thermostat e e S189P20 Powersupply box for Duo unit rfr e e S210P15 On Off switch A option Lagere option option S128P15 E switch louer Half door switch Ceiling light E eee 15104 15 893010contacto H K22 E6 contactor ee el cable clamp BEE Power cord Instructions 648270 Page 20 BONNET DECLARATION DE CONFORMITE CONFORMITY DECLARATION HERSTELLERKONFORMITATSERKLARUNG TYPE TYP N DE SERIE SERIAL N FAB Nr Sn a nach i ae ae he a en cos BANA IYA Red ed em KA KANGA BA ee ah el Cet appareil est conforme aux dispositions de la directive Basse tension 73 23 CEE et de la directive Compatibilit lectromagn tique 89 336 CEE This appliance complies with the provisions of the low voltage directive EEC 73 23 and with the provisions of the electromagnetic compatibility directive EEC 89 336 Dieses Ger t entspricht nach den Bestimungen der niederspannung richtlinie EWG 73 23 und den Bestimmungen der elektromagnetischen Ubereinstimmung richtlinie EWG 89 336 Il est galement conforme aux dispositions de normes europ ennes harmonis es suivantes It i
8. 8 8 d3 Defrost duration O without 0 99 mn 30 45 d4 Defrost at powering O no 1 yes 0 1 0 0 95 Defrost delay at powering 0 31 mn 0 0 d6 Defrost locked display 0 no 1 yes 0 1 0 0 d7 Evaporator draining time 0 15 mn 4 2 5 d8 Alarm exclusion time after defrost 0 15 H 3 3 d9 Compressor time if d121 O no 1 yes 0 15 mn 4 0 0 1 dA Reading the ambient probe C 2 4 AO Alarm differential 1 15 2 2 2 A1 Low alarm relative to the set point O without 55 0 C 2 0 0 A2 High alarm relative to the set point O without 0 99 C 2 10 10 A3 Alarm exlusion at powering 3 0 15 H 2 3 4 0 240 mn 4 120 120 5 Buzzer delay upon malfunction if iO 40 1 without 1 120 mn 4 1 1 A6 Exclusion time if A1 and or A220 0 99 mn 15 15 A7 Delay time after the ventilation stops if A1 and or A240 0 240 mn 4 15 15 FANS Ventilation stop set point if A 1 and F7 3 or 4 Differential relative to F1 if A 1 and F7 3 or 4 Fan during defrost O without 1 forced suivant F7 Ventilation delay after defrost Fan set point O absolute 1 temperature related Ventilation running O without 1 forced 2 with compressor 3 as per F1 and F2 4 as pert F1 and F2 with compressor MULTIFUNCTION INPUTS 10 Action provoked O without 1 after defrost d5 2 reserved 0 5 4 0 0 3 compressor forced 4 compressor ventilation off 5 ventilati
9. addition the spare nylon washer code S024P07 supplied can be used to raise the door if the lock or door switch doesn t operate correctly This washer should be fitted between the hinge support and the door It is supplied selotaped to the top of lt gt N the cabinet Lower hinge support Instructions n 648270 Page 11 4 5 REVERSING THE DOOR OPENING DIRECTION NOTE this is only possible on single door units 1 Remove the door as shown in paragraph 4 3 2 Move the lower hinge support to the other side 3 Reverse the spring hinge and the Delrin hinge fixed with 17 x 4 8mm rivets 4 Reverse the door catch fixed with 17 x 4 8mm rivets The control panel can now be reversed 1 Remove the electric panel cover 2 x 4mm screws 2 Remove the control panel 3 Remove door lock pin using a flat 7mm spanner Fit to the other side only after having repositioned the electric panel 4 Remove the electronic thermostat to turn it over Disconnect the wires having marked the cables 5 Change the stop start the door and light switch to the other side The necessary cut outs are already there 6 Remove the electric panel so it can be fitted the other way round 7 Reverse the BIOSTORE badge by unclipping the blue profile Undo one of the two end plugs slightly 8 Unstick the BONNET badge to replace it with the new one supplied After the control panel has been put back in place refit the door as indicated in paragraph 4 3
10. ar Door clip e e e e 5053 01 Lock e e e e e e S129P01 Catch bol e e e e S098PM46 Hinge support bottom L top R e e e e S098PN46 Hinge support bottom R top L ele SttePot Central half door hinge support em Central half door hinge support EE pic tp eo Ms pin for hinge without return e e e so83P01 Sprung hinge e e e SOBPO Delrin hinge e e e e S024P07 Jaen washer 18 Instructions 648270 Page 18 6 2 REFRIGERATING AND ELECTRIC EQUIPMENT eur PE SE ee CODE DESIGNATION S183P40 60 TB Compressor e S184P40 ML 80 TB Compressor e e S077P40 CAE 24247 compressor e S243P40 CAJ 24462 compressor 92240 condenser 93240 condenser 103270 condenser S057P30 104270 condenser S071P40 EVR7A 230 condenser fan e S072P40 EVR10A 254 condenser fan S238P46 EVR7A 230 fan venturi S239P46 EVR10A 254 fan venturi S021P20 i5greXH9dryer E U W i Saeed ce 8074P20 4 EVHS3 1 4 solenoid valve III S009PL58 capillary evaporator housing S009PS58 capillary evaporator housing S009PM58 T E V evaporator housing soogPPse capillary evaporator housing 5009 58 T E V evaporator housing 8010
11. it continues to operate This means that during periods of heavy duty service or large scale or lengthy loading the front of the evaporator is not blocked by frost FREEZING CABINETS Ventilation is stopped in the following cases by switches actuated on door openings by the thermostat during defrost with a ventilation delay until 12 C 2 4 DEFROST The internal timer of the electronic thermostat sets up the start up and the end of the defrost On freezing cabinets defrost end is controlled at 5 C with a ventilation delay at 12 C The factory setting can be adjusted according to needs The operation can only be performed by the installer see instructions 2 5 DEFROST WATER COLLECTION A container on the back of the cabinet collects defrost water which is evaporated automatically by hot gas coil or a self regulating electric element on twin temperature units User manuel n 648270 Page 4 3 SERVICE IMPORTANT Before any cleaning operation ensure the appliance is switched OFF Do not clean the appliance with a water jet in order to avoid water spattering 3 1 INTERIOR LINING It is necessary to eliminate stains once per day To ease the complete cleaning of the interior lining the internal fitting can be easily disassembled shelves slides and slides supports 3 2 STAINLESS STEEL SURFACE Using warm water and soap or a non corrosive neutral detergent such as teepol or an equivalent product Careful
12. E FECHNIQUE REFRIGERATED CABINETS BIOSTORE STAINLESS EXT SR 600 SR 1300 SN 600 SN 1300 WHITE EXT SRB 600 SRB 1300 SNB 600 SNB 1300 2 DOORS SRR 2x300 SRN 2X300 TECHNICAL MANUAL USER MANUAL INSTRUCTIONS DOCUMENTATION BONNET GRANDE CUISINE Rue des Fr res Lumi re Z I Mitry Compans 77292 MITRY MORY cedex T l 01 60 93 70 00 Fax 01 60 93 70 43 FORM050B1 1 648270 05 06 USER MANUAL REFRIGERATED CABINETS BIOSTORE STAINLESS EXT SR 600 SR 1300 SN 600 SN 1300 WHITE EXT SRB 600 SRB 1300 SNB 600 SNB 1300 2 DOORS SRR 2x300 SRN 2x300 CONTENTS Important recommandations 1 Presentation of the control panel 2 Use a amp C N 3 Service BONNET GRANDE CUISINE Rue des Fr res Lumi re Z I Mitry Compans 77292 MITRY MORY cedex T l 01 60 93 70 00 Fax 01 60 93 70 43 User manuel n 648270 Page 1 IMPORTANT RECOMMENDATIONS This unit is designed for use in Restaurants or Catering facilities It is not intended for industrial Installation should be undertaken by a refrigeration engineer Avoid installing the unit near major sources of heat or in direct sunlight Note that too high an ambient temperature can reduce performance The compressor condenser must be cleaned regularly every 3 to 6 months by a refrigeration engineer Do not modify the electrical connection made during installation particularly the earth con
13. and not stacked If moving the appliance without its pallet it must be carried and not pulled 2 3 UNPACKING AND INSTALLATION 2 3 1 LOCATION When choosing the location make sure that there is sufficient air circulation around the appliance to allow correct cooling of the condenser and compressor Do not install near a source of heat 2 3 2 UNPACKING Follow the instructions supplied with the unit 2 3 3 CONNECTIONS See paragraph 1 Technical data ELECTRIC The unit is fitted with a plug which should not be removed This appliance must be EARTHED see important recommendations The supply should incorporate a suitable fuse or circuit breaker DEFROST WATER The melt water collection container can be replaced by a direct connection to drain 20mm pipework Instructions n 648270 Page 6 3 OPERATION 3 1 GENERAL REQUIREMENTS Ensure that the condenser fan and evaporator are not obstructed If the appliance has been laid down during transport or handling wait 24 hours before use to allow refrigerant oil to return to the compressor For units with grills fit the runners to their supports 3 2 CONTROL PANEL LAYOUT See USER MANUAL 3 3 THERMOSTAT CONFIGURATION FRIDGE MODEL FREEZER MODEL Set button Led compressor running Decrease button Led defrost running Increase button Led evaporator fan running There are 2 configu
14. at 30 55 C sl LE Se Refrigerant R404A R404A S E Load See appliance instruction plate Z Compressor Hermetic Condenser Forced air Evaporator Ventilated double flow corrosion proof 1990 1590 1470 H D b gt eae gt gt gt i s gt 2 86 540 86 94 60 592 60 x S 720 RIX S S 1565 x m Defrost water chilling model Ventilated for freezing Catchment container on the rear of the cabinet with automatic hot gas re evaporation Complies with F Electric safety Food hygiene Complies with E C requirements DO EN 60 335 1 XP U 60 010 Instructions n 648270 Page 3 50 ee groupe 1 2 1 SRB SR 1300 and SNB SN 1300 SRB SR 1300 142 920 50 870 250 1990 1590 EAM 630 82 94 58 1470 gt T T L 157 60 1304 1565 250 1990 1590 150 61 lt
15. breaker or fuses are installed 721 INNA Chilling Freezing 1 3 2 SRN 24300 Refr power 320 W 450 W at 15 55 at 30 55 920 Refrigerant R404A R404A 720 50 870 30 groupe Load See appliance instruction plate Compressor Hermetic Condenser Forced air G m Evaporator Ventilated double flow corrosion proof chilling model Ventilated for freezing Defrost water Collection tray located in the back of the 7 cabinet with automatic re evaporation L D re of defrost water by self regulated heater 25 W i N 99 6855 1990 1590 N 685 5 Complies with Electric safety EN 60 335 1 D 0 I UL J Food hygiene XP U 60 010 So vi 56 d em i7 Complies with E C requirements 150 60 600 60 60 NG INNA 721 a d ES Instructions n 648270 Page 5 2 INSTALLATION 2 1 GENERAL REQUIREMENTS The appliance must be installed modified and repaired by a specialized engineer in accordance with current regulations 2 2 HANDLING The appliance must be handled with suitable lifting equipment transported on its original pallet
16. e Ev h upper solenoid valve KA compressor contactor Veh upper evaporator fan Lp h upper lighting lamp Ip h upper lighting door switch Cp Compressor Vc condenser fan M A b lower On Off switch K2C compressor relay 2 EV b lower solenoid valve Ve b lower evaporator fan KbE lower lighting relay Lp b lower lighting lamp Ip b lower lighting door switch SdA b lower temperature probe SdE b lower evaporator probe Rev evaporation heater erem So EE mu ul KC Alim 22123 22 2 Unit de Puissance bas V Sd Sd 7 A SITES CIT SdEb gt DER Thermostat LJ UJ J Ev h Ve h Rev Ve b Ev b Ve Instructions n 648270 Page 15 5 4 TWIN DOOR CABINETS PRINCIPLE DIAGRAM CONNECTING DIAGRAM N SE242 M A h On Off switch Tr Transfo Th Thermostat SdA h upper temperature probe Ev h upper solenoid valve KA Compressor contactor Veh upper evaporator fan Lp h upper lighting lamp Ip h upper lighting door switch Cp Compressor Vc condenser fan M A b lower On Off switch K2C compressor relay 2 EV b lower solenoid valve KD defrost relay Rd defrost heater Re flow heater KV fan relay Ve b lower evaporator fan KbE lower lighting relay Lp b lower lighting lamp Rp door heater Ip b
17. emoving the screws Instructions n 648270 Page 10 4 3 REPLACING THE DOOR gt H gt IL e d 2 Zz A 2 E L H 2 5 2 T e JA DIR H WY 1 WP 1 Door re assembly 1 Remove screw 6 which holds the control panel to the side of the top housing 2 Remove the M5 axis 4 by unscrewing it 13 Remove the hinge support 3 by undoing the 2 screws 5 4 Lift the door 1 to raise it off the lower hinge support Note in the event that the sprung hinge 2 is disarmed use the hinge support 3 to turn it 120 in the direction the door opens 1 Once confident that the sprung hinge 2 is armed position the door onto the lower hinge support with the door in the closed position Lift the control panel slightly to ensure that the square axis of the sprung hinge 2 is correctly located 2 Engage the upper hinge support 3 onto the square axis of the sprung hinge 2 Turn the hinge support so that the holes line up Tighten with the screws 5 3 Refit the M5 axis 4 then the control panel fixing screw 6 4 4 ADJUSTING THE DOOR Ensure that the door is central to the cabinet 6mm from each edge of the door and 12mm between doors on two door cabinets To adjust the door position the lower hinge support can be moved to the left or the right of the unit In
18. h the arrows buttons 2 or 3 Press both arrows buttons 2 and 3 for 4 sec Press the arrows buttons 2 or 3 To see and then modify the value of the selected parameter el 1 having selected parameter PA To adjust the value 19 The first parameter of level 2 is displayed 0 To select the parameter to change Then press SET button 1 and adjust with To see and then modify the value of the the arrows buttons 2 or 3 selected parameter To exit press both arrows at the same time buttons 2 and 3 for 4 secs or wait at least 50 secs without touching anything Instructions n 648270 Page 8 3 3 3 PARAMETERS BOARD Presettings Code Parameters Mini Maxi U Chilling Freez i PA Password _ _ Toseto 19 55 9 T PROBE Probe type 1 PTC 3 NTC Ambient probe calibration 8 pts to correct 19 Evaporator probe calibration 8 pts to correct 19 Unit of temperature 0 F 1 C Evaporator probe activation O n0 1 yes Differential minimal value of the set point maximal value of the set point Delay at powering Delay after start Delay after stop Compressor if faulty probe O OFF 1 ON Delay ON OFF 0 0 1 3sec Compressor cycle duration if probe faulty Percentage of C5 if probe faulty dO Defrost time O without 0 99 H 8 9 di Defrost type O Elect 1 Hot gas 0 1 4 0 0 d2 Defrost end temperature 55 99 2 4
19. ly rince and dry the appliance Never use Javell water even when highly diluted Never rub stainless steel with metal wool if necessary use only scotch brite or an equivalent product Fingerprints in particular can be easily removed by rubbing with a cloth soaked in alcohol 3 3 PERIODICAL CLEANING Magnetic door seal can be removed to ease the cleaning In order to maintain the refrigerating capacity and to ensure the longevity of the compressor it is necessary to clean regularly every 3 or 6 months the condenser This operation must be carried out by the installer User manuel n 648270 Page 5 INSTRUCTIONS REFRIGERATED CABINETS BIOSTORE STAINLESS EXT SR 600 SR 1300 SN 600 SN 1300 WHITE EXT SRB 600 SRB 1300 SNB 600 SNB 1300 2 DOORS SRR 2x300 SRN 2x300 CONTENTS Important recommendations 1 Technical data 2 Installation 3 Operation 4 Intervention and repair 5 Electrical diagrams o O A C N 6 Spare parts BONNET GRANDE CUISINE Rue des Fr res Lumi re Z I Mitry Compans 77292 MITRY MORY cedex T l 01 60 93 70 00 Fax 01 60 93 70 43 Instructions n 648270 Page 1 IMPORTANT RECOMMENDATIONS When installing the appliance ensure that there is adequate circulation and air volume to cool the condenser and compressor Avoid installing the appliance near major sources of heat or in direct sunlight Note that too high an ambient temperature can red
20. on off it Multifunction contact type if i020 O NO 1 NF 4 0 SERIAL PORT FOR DATA EXCHANGE Li Unit address 1 E L2 Unit compressor L4 Baud 021200 122400 2 T CO 32 9600 Configuration parameters at level 1 Configuration specific to SN shada Unit according to configuration of the 8 parameter Configuration parameters specific to freezing model Parameters bottom compartment DUO Instructions 648270 Page 9 4 INTERVENTIONS AND REPAIRS IMPORTANT Before any operation ensure the appliance is switched OFF 4 1 ACCESS TO COMPRESSOR UNIT Cleaning the condenser can be done from the top of the cabinet without dismantling the control panel Access to the compressor is easier if the entire control board assembly is removed in this case the top of the door must be supported because the hinge must be removed to get the control panel off 4 2 EVAPORATOR ACCESS Take out the rubber elbow from housing and push back the flow tube to the outside giving a quarter turn to get out the external drain trap from vaporizer fixed to the back of the cabinet As for freezing cabinets take out flow resistance to avoid hazards Make sure to put it correctly while reassemblying it into the flow tube On the freezer cabinets with the ABS housing this is removed by unclipping it using a screwdriver or flat bladed tool or completely r
21. ration levels Level 1 Password access to level 2 code PA Differential setting code rO To calibrate the ambient probe code 1 not fridges To calibrate the evaporator probe code 6 not fridges To read the evaporator probe temperature code dA not fridges Level2 From level 1 to select and modify the parameters password protected see parameter table Instructions n 648270 Page 7 3 3 1 SIGNALS AND ALARMS EO probe is defective or the temperature is flashes on the display and the buzzer sounds intermittently because the ambient outside the set limits flashes on the display and the buzzer sounds intermittently because the evaporator flashes on the display and the buzzer sounds intermittently due to a parameter data E1 probe is defective not on fridges E2 memorization fault switch off and on again 15 temperature flashes on the display and the buzzer sounds intermittently if the units temperature is outside the limits set parameters A1 or A2 Flashing LEDs indicate a delayed start for the corresponding function 3 3 2 PARAMETER CONFIGURATION ACCESS TO LEVEL 1 Press both arrows buttons 2 and 3 for 4 sec PA appears in the display Press the arrows buttons 2 or 3 To select the parameter to change Then press SET button 1 and adjust with the arrows buttons 2 or 3 ACCESS TO LEVEL 2 starting from lev Press and hold SET button 1 and adjust wit
22. s in compliance with the following harmonized standards Und entspricht ebenfalls der folgenden Europaischen Norme EN 60335 1 S curit des appareils lectrodomestiques et analogues Safety of houseold and similar electrical appliances Elektrische Ger te f r den Hausfebrauch und hnliche Zwecke DIRECTION GENERALE G n ral Manager Betriebsleiter keal FORMO55A1 1 Si ge Social BONNET GRANDE CUISINE Rue de Fr res Lumi re Z I de MITRY COMPANS 77292 MITRY MORY CEDEX T l 0160937000 Fax 0160937043 S A S au capital de 1 600 000 Euros RCS MEAUX B 319 053 005
23. se of the risk of dammaging the refrigerating equipment 1 2 CONTROL PANEL a U A Electronic On Off switch regulator 1 3 USING THE ELECTRONIC CONTROL THERMOSTAT FRIDGE MODEL FREEZER MODEL Set button Led compressor running Decrease button Led defrost running Q Increase button Led evaporator fan running The digital electronic thermostat indicates the temperature detected by the ambient probe To display the set temperature press Set button 1 Change this setting by continuing to press on the Set button and pressing the arrows 2 and 3 to decrease or increase the temperature setting A manual defrost can be started by pressing button 3 To silence an audible alarm pressing button 2 stops the buzzer User manuel n 648270 Page 3 2 USE 2 1 GENERAL REQUIREMENTS At first operation or after a long stop a prefunction cycle must be launched Goods must only be loaded when the temperature set by the thermostat has been reached Do not store food products in any way likely to hinder the air circulation which ensures the correct distribution of cold air inside the appliance 2 2 LOADING The loading must be made leaving a space of approximately 15 mm between each product to ease air circulation 2 3 VENTILATION CHILLING CABINETS Ventilation is deliberately permanent When the doors are opened
24. tinuity circuit The supply cable that is fitted is a specific part and should only be replaced with an original part Ensure that the plug is easily accessible In the event of problems with the electrical circuit only the installer or the manufacturer should intervene Observe hygiene guidelines by regularly cleaning the following interior fittings door seal interior lining Do not use corrosive or acidic products Water splashing can cause damage To avoid the risk of splash damage do not clean with a hose or high pressure spray Do not locate the unit where it is exposed to the elements Reference to the label NF FOOD HYGIENE Certified by AFAQ AFNOR Certification 11 Avenue Francis de Pressens 93571 SAINT DENIS LA PLAINE Cedex France The label NF FOOD HYGIENE complies with the NF031 requirement The main certified characteristics are Cleaning qualification Refrigerating performances f the installation the use or the service is modified the appliance will lose the right to use the label NF FOOD HYGIENE SPECIFICATION AND CHARACTERISTICS IN THIS DOCUMENT MAY BE SUBJECT TO BE MODIFIED WITHOUT PRIOR NOTICE User manuel n 648270 Page 2 1 PRESENTATION OF THE CONTROL PANEL 1 1 IMPORTANT The thermostat does not cut off the general power of the appliance If the appliance is not used during a long time power must be cut off with the On Off switch the plug or the disconnector becau
25. uce performance There must be earth continuity between the appliance and the mains connections The supply cable that is fitted is a specific part and should only be replaced with an original part Ensure that the plug is easily accessible The installer should ensure that the electrical connection is suitably protected by an appropriate fuse or circuit breaker see rating plate Ensure that the appliance is switched OFF before any intervention on the electrical or refrigeration circuits and during cleaning The compressor condenser must be cleaned regularly every 3 to 6 months Water splashing can cause damage To avoid the risk of splash damage do not clean with a hose or high pressure spray Do not locate the unit where it is exposed to the elements After any intervention ensure that the original installation guidelines are respected to avoid any form of risk Reference to the label NF FOOD HYGIENE Certified by AFAQ AFNOR Certification 11 Avenue Francis de Pressens 93571 SAINT DENIS LA PLAINE Cedex France The label NF FOOD HYGIENE complies with the NF031 requirement The main certified characteristics are Cleaning qualification Refrigerating performances f the installation the use or the service is modified the appliance will lose the right to use the label NF FOOD HYGIENE SPECIFICATION AND CHARACTERISTICS IN THIS DOCUMENT MAY BE SUBJECT TO BE MODIFIED WITHOUT PRIOR NOTICE Instr
26. uctions n 648270 Page 2 1 TECHNICAL DATA 1 1 SRB SR 600 and SNB SN 600 CONSTRUCTION 1 1 1 SRB SR 600 Austenitic stainless or white plasticized sheet exterior casing sides front panel door Austenitic stainless interior lining RENI Back top and bottom of the exterior casing in corrosion 8 proof galvanized sheet 3 Austenitic stainless door liner Insulated body Monocoque type el E Radiused interior TB Polyurethane foam insulation 60mm thick Thermal break between inner and outer structure 4 adjustable legs or optional casters Anti condensation door frame heater for freezing cabinet Plain door 1 Easily removable magnetic door seal RSC Door with security lock T 197 90 hold and self closing door Door opening can be reversed 60 592 60 EI TECHNICAL DATA si TNI Voltage 14230V 50 Cycle Chilling Freezing Il g Input power 1470 W 700 W 7 A Protection aM A aM A Delivered with moulded plug The installer is responsible for protecting the appliance against overloads or electrical defects Ensure a circuit breaker or ad fuses are installed 1 1 2 SRB SR 600 x es Chilling Freezing 1 ee E real Refr power 321 W 555 W at 15 55 C

Download Pdf Manuals

image

Related Search

Related Contents

WithStrings SensorUtils Manual 1. Description SensorUtils is a utility  ASTRO WHITE-COLOR- user manual V1,1 - COMPLETE  guide de la petite enfance  bdiGDB User Manual    Sesam 2011 DVD Release Notes  Telereef Controller - User Manual  warning  Les conditions d`engagement de la Bundeswehr dans des  (2014-07-22 Gewährleistungszertifikat FR V07)  