Home
Catalogue - bsa power
Contents
1. Powering Business Worldwide 2 Contents Corporate Overview LLuaunseanmseedeanenmmnmninie 3 Sustainable by Design srsvrvrnrnvnvnvnvnvnnevrnvnvnvnvrvsvrnenrnvnrnenenennnnnnnr 4 About Eaton s Solutions rsrsvsvrvrsrnvnnnnrnenvnnvnenenvrnrnrnennrnenennsnenenener 5 UPS Solution Overview srarrvrnrvvnrsvnrerenenrnvrveveverenerervererenevenvsvsvenevenenenne 6 Advanced Technologies ssrsvrvrnvnnrnvnnrnvnvrnenernrnennrnvnnenernenennvnennn 7 Hot Sync MG CN ONO EE neniani 8 ABM Technology 9 Energy Advantage Architecture Energy Saver System 10 Energy Advantage Architecture Variable Module Management SEE ccc ase deces ccc etccctcaunctcocacediencsdiceandstsesectdencediaceseteee 11 Protecting your investment snsnrnonnrnonnrnvnnvnvnnrnenvrnenernrnnnnenernene 12 Se E AA 12 dende SEM au 13 Series 3 Single Phase UPS rsrnrnrnvnvnnnnrnrnrnvnvsvsvnnenrnrnvnenenennnnnr 14 Mn Se 14 Eaton Ellipse ED Lunge de 15 Series 5 Single Phase UPS rsrrnrnvrnrnrnrnvnvnvsvsvnnevvnvnvnenenennnnner 16 FE 16 FONN 17 EA 110 ge EE EE east hte tested eee aa eerie 18 FP 20 FINN 22 Faton EE 24 Series 9 Single Phase UPS rsrnrnrnvnvnnrnrnrnrnvnvnvsvsnenrnrnvnenenennnnnr 26 Eaton E Series DX scscssiccacosnicsvadsecstansisoncasecestanesngnienneddionneisnealnccseasien 26 2 110112 E EE A 28 Eaton 9130 Tonehunsussmmucvqmsmeasmmed nunatddmk 30 FANT Rake 32 EON S EE arenes 34 EST
2. sags swells and transients e Analyse event severity according to IT standards e See your power quality at a glance Leverage Power Xpert Architecture to establish a unified management approach for your enterprise The solution is based on open standards so that devices can communicate It synchronises equipment clocks through a network time server so you can accurately correlate events at different points in the system Power Xpert Architecture lt s one of Eaton s powerful innovations in facility monitoring and management For additional information about Power Xpert Architecture and to download the product data sheets visit www eaton com powerxpert EATON CORPORATION UPS and Power Quality Products Catalogue Power Management Power and Energy Meters Power Xpert Meter 4000 6000 8000 Eaton s Power Xpert Meter series represents world class power monitoring that reduces day to day operating costs and helps avoid costly business interruptions The meters combine state of the art technology with an embedded Web server advanced power diagnostics data trending and performance benchmarking along with a twist n click LCD for simplicity and ease of use Features and Benefits e Free download of power Xpert Meter Profiler to trend and predict energy usage e Embedded Web Server e Automatic power quality analysis and trigger setting with built in ITIC performance curve Comprehensive power energy and d
3. Part Numbers 1500 2000 2200 3000 RT3U 3000 RT2U UPS 5PX1500iRT 5PX2000iRT 5PX2200iRT2UAU 5PX3000iRT3UAU 5PX3000iRT2UAU EBM 5PXEBM48RT 5PXEBM48RT 5PXEBM48RT 5PXEBM72RT3U 5PXEBM72RT2U www eaton com powerquality 1300 UPS UPS 25 26 Essential series 9 Power Protection F F S DX Features aton erf es e Double conversion topology assures maximum reliability e Wide input voltage range appropriate for the harshest electrical environments e Tested for generator compatibility e Standard Models for fixed run time performance e XL Models for customised long run time applications with fast recharging e Automatic bypass for fault tolerance e Built in maintenance bypass on 6 20kVA models e Optional SNMP communications provides remote network based monitoring e Cold start on battery power allows portable power e WINPOWER software monitors power conditions e Intuitive front panel LED user interface for consistent status indication e 6 20kVA models are parallelable for increased capacity and or redundancy Options Technology Series 9 Double Conversion On Line e SNMP Web Card Rating 1kVA 20kVA e Relay Card Voltage 230 240V e Modbus Card Backup Time Typical 5 min e External Maintenance Bypass Switch Configuration Tower e Extended Battery Cabinets The E Series DX UPS double conversion UPS affordably protects mission critical applications from downtime data loss and corruption
4. as specified by ANSI IEEE C62 41 1980 and is covered by the SECV Certificate of Suitability Number CS84292V Built to protect e Programmable logical controls PLC e Photographic equipment e Remote computer peripherals e Copiers and laser printers e Process control equipment e CNC machinery e Entire installations Specifications Ordering details 220 or 240 Volt AC Rated PartNumber Current Output i Enclosure ae oa Input Voltage Range 10 20 40 500 210 26 650 00 208 210 26 650 00 2 08 Protection ANSI IEEE C62 41 1980 A and B waveforms 210 26 710 00 suppressed to safe levels 1000 210 26 710 00 S 7 7 Nominal Voltage 220 or 240 Volt AC 2000 ere eo 1041 220 Volt In Out Hardwired Units Voltage Regulation 3 for 10 20 input 5 8 for 40 input Rated Part Current Weight kg Enclosure AC on off switch Output VA Number AMPS Cont Size Note 3 ontrol on off switc 7 500 20 44 650 Response Correction Return to regulation envelope within 30 msec Dynamic Response Continuous and smooth correction for input 2500 200 44 725 11 36 voltage fluctuations 200 of rated load for 10 seconds without EN j damage 500 of rated load for 10 msec 1 240 Volt Hardwired options available to order Electrical Noise Attenuation 2 Special voltage configurations available to order 60 dB typical 80 dB max 4kHz to 20 MHz 3 Enclosure sizes mm Size 3 195 H x 210 W x
5. e New unit delivered direct to the customer site nationally Eaton covers all logistics costs e Next Business Day Response onsite for hardwired single phase UPS systems 3 1kVA 11 kVA e Eaton to organise collection of the faulty unit for disposal if required Access Eaton customer service centre 5x8 NOOS NIWNOJ 2 Warranty Premium e Applicable for Eaton s hardwired single phase UPS systems 3 1kVA 11kVA e Available for 3rd or 4th year uplift e Same business day dispatch advance replacement e Next Business Day Response onsite e Startup Commissioning including basic UPS functionality operator training plus 1 x preventative maintenance visit with report per year conducted during business hours e Eaton to organise collection of the faulty unit for disposal if required Access Eaton customer service centre 24 x 7 e ig b Bo ee mi mi i lier GE EE Notes 1 Same business day dispatch of Eaton Single Phase UPS products up to 11kVA excludes Eaton 9155 amp MX Frame UPS with Advance Replacement and all logistics nationally e Softwired Eaton UPS lt 3kVA is the customers responsibility to re install e Hardwired Eaton UPS 3 1kVA 11kVA excludes Eaton 9155 amp MX Frame UPS replacement parts will be dispatched to site in advance or taken with the Service technician at the next business day onsite response e The cut off time for dispatch is 3 00 p m AEST AESDT
6. 1 and 3 Phase 40kA and 100kA Shunt Surge Diverter 1 Pole 60kA Integrated Surge Protection Device Internally HRC Fused 1 Pole 60kA Neutral Earth or Earth Earth Equipotential Clamp 50kA Series filter with Shunt Surge Diverter Class ll Cat C amp B 1 amp 3 Phase 63 80A 100kA Series Surge Filters Series Filter with Shunt Surge Diverter 1 Phase 5 32A 40kA Primary Series Filter with Shunt Surge Diverter 1 Phase 3 25A 25kA Primary EATON CORPORATION UPS and Power Quality Products Catalogue 10 Portable Surge Filter 1 Phase 10A amp 16A 25kA Primary and 140kA Primary 11 Single Phase Rack Mounted Filter PDU Power Conditioners Sola Power Conditioners Eaton s Sola ferroresonant products are proven technology In 1938 Sola was awarded the first patent for ferroresonant power conditioners the constant voltage transformer Since then our technology has remained at the forefront of ferroresonant power conditioning Today Eaton s Sola ferroresonant power conditioners supply sinewave output which is especially important for computer applications Whether you purchase a model 200 210 or 26 voltage regulator you can count on an average of 25 years service from your unit Every ferroresonant power conditioner is manufactured to exacting specifications and is subject to rigorous quality control The ferroresonant power conditioners protect equipment from all power problems other than
7. Yet invisible and fleeting power disturbances can be silent killers often going unmonitored and unnoticed With Eaton s Power Xpert Architecture the backbone of our PowerChain Management solutions you gain unprecedented visibility into the entire power system A framework to view your entire power system Power Xpert Architecture encompasses conditioned power in the data centre as well as unconditioned power coming into the facility Through hardware software and communication elements the architecture unites diverse power components across your enterprise into a single view old and new PDUs batteries and other critical equipment from multiple manufacturers So you can monitor control and manage the power system more effectively and efficiently as you correlate events across the power system drill into details for quick diagnosis and use tools to determine appropriate actions Software users view monitor and manage information Web Browsers view Power Xpert Software amp components PowerXpert Dashboards view the status of your power chain ata glance PowerXpert Server Core Software to help you model monitor and manage your power chain about their power chain A simple Web based interface helps you to e Understand energy usage patterns and baselines Reduce peak loads identify high energy users and realise energy savings e Find the real causes of issues including power event ghosts
8. 25 C to 55 C 1000m without derating Maximum 2000m 55dB 75 Load 60dB 100 Load IEC 62040 1 IEC 62040 2 IEC 62040 3 www eaton com powerquality 1300 UPS UPS 51 Premier Modular High Efficiency UPS Solutions 200 1100kVA AY D nar aa Ar OQ OK Features Delivers the highest reliability and availability for large mission critical systems by integrating a redundant multi module UPS including the System Bypass Module into a single pre wired unit Grows with changing power requirements with scalable architecture that allows you to add another 275 kVA module on site later for capacity or redundancy Eliminates the need to switch to bypass for service with concurrent serviceability One redundant 275 kVA module can be isolated and serviced while the other is online Provides unmatched power performance for efficiency input current harmonic distortion THD and power factor Ensures battery reliability with innovative ABM three stage charging system battery health checks optional temperature compensated charging and remote monitoring Lowers installation time and costs with small footprint and the flexibility to install against walls using top or bottom entry cabling and by eliminating the need to run inter unit cabling on site with pre wired configuration Integrates seamlessly with PowerXpert software to enable you to monitor and manage the UPS as well as the entire power system including all
9. 440 19 130 3U 700mm 23kg 3 1 Customer Service and Support Warranty 3 years electronics 2 years battery Runtimes are shown at 0 7 power factor Backup times are approximate and may vary with equipment configuration battery age temperature etc Part Numbers 9PX 6kVA 9PX 8kVA 9PX 11kVA UPS 1 1 9PX6Ki 7 3 Power Module 3 1 9PX6Ki31PM 1 1 9PX8KiPM 3 1 9PX8Ki31PM 1 1 9PX11KiPM 3 1 9PX11ki31PM EBM 1 1 9PXEBM180 3 1 9PXEBM240 9PXEBM240 9PXEBM240 HotSwap Maintenance Bypass 1 1 MBP6Ki 3 1 MBP11Ki31 1 1 MBP11Ki 3 1 MBP11Ki31 1 1 MBP11Ki 3 1 MBP11Ki31 Transformer Module Single Phase in out TFMR11Ki TFMR11Ki TFMR11Ki Supercharger with Rack Kit 1 1 N A 3 1 SC240RT SC240RT SC240RT 1 8m Battery Connection Cable 1 1 EBMCBL180 3 1 EBMCBL240 EBMCBL240 EBMCBL240 Battery Integration System BINTSYS BINTSYS BINTSYS Rack Kit 9RK 9RK 9RK www eaton com powerquality 1300 UPS UPS 37 Premier series 9 protection for centralised mission critical loads Product highlights Eaton 9 l 5 5 e Hot Sync redundancy e ABM providing up to 50 longer battery life time Active input power factor correction PFC providing 2 5 THD i harmonics e High 0 9 p f output rating for server and high computer loads e Market leading internal battery runtime e User friendly graphical LCD display with light blue back light e Web SNMP and ModBus monitor
10. 91 online 93 High Efficiency Mode 6000VA 95 online 98 High Efficiency Mode User interface LCD display LCD display showing both UPS meters and UPS settings LED Four LEDs UPS On UPS on Battery UPS on bypass Alarm Standard communication ports RS232 and USB as standard on all models Optional 1 Mini Slot for Network Card MS Relay Card MS or Network amp Modbus Card MS connectivity cards Environmental Operating temperature 0 C 40 C Storage temperature 15 C 40 C Altitude lt 3000 m Audible noise at 1 metre 700 3000VA lt 52 dBA 6000VA lt 55 dBA Certification Markings C Tick CE GS EMC EN62040 2 Emissions category C1 Immunity category C2 Battery Runtimes in minutes Standard Extended Battery Modules Load VA Watts Of Load Internal Batteries w 1 EBM w 2 EBM w 3 EBM w 4 EBM PW9130G700T 700 630 100 5 N A N A N A N A 350 315 50 14 N A N A N A N A PW9130G1000T XLAU 1000 900 100 6 31 51 82 100 500 450 50 19 68 111 192 246 PW9130G1500T XLAU 1500 1350 100 5 24 46 69 90 750 675 50 14 61 112 172 221 PW9130G2000T XLAU 2000 1800 100 11 44 79 115 162 1000 900 50 28 96 168 258 336 PW9130G3000T XLAU 3000 2700 100 6 21 51 66 93 1500 1350 50 15 60 100 169 215 PW9130G6000T XLAU 6000 5400 100 6 33 64 96 130 3000 2700 50 19 78
11. Dimensions H x W x D Weight UPS 440 19 130 3U 685mm 48kg 440 19 130 3U 685mm 48kg EBM 440 19 130 3U 645mm 68kg 440 19 130 3U 645mm 68kg Customer Service and Support Warranty 2 years warranty Runtimes are shown at 0 7 power factor Backup times are approximate and may vary with equipment configuration battery age temperature etc Part Numbers 9SX 5kVA 9SX 6kVA UPS UPS with Rack Kit 9SX5KIRT 9SX6KIRT EBM EBM with Rack Kit 9SXEBM180RT 9SXEBM180RT Power Module HotSwap Maintenance ByPass MBP6Ki MBP6Ki Transformer Module TFMR11Ki TFMR11Ki Supercharger with Rack Kit 1 8m Battery Connection Cable EBMCBL180 EBMCBL180 Battery Integration System BINTSYS BINTSYS www eaton com powerquality 1300 UPS UPS 35 Premier series 9 power protection for medium to high density rack environments Eaton 9 PX e The 9PX offers Serial USB and relay connectivity plus an extra slot for an optional card Ethernet Network Voltage Free Contact Relay or Modbus amp Network Eaton s Intelligent Power Software Suite compatible with all major OS including virtualisation software such as VMware and Hyper V is included with each UPS Availability and Flexibility e The internal bypass allows service continuity in case of internal fault a Maintenance Bypass Module is also available for easy UPS replacement without interruption to the critical load fo
12. Frame Total flexibility e Can be used as a free standing tower unit with casters or 19 rack mounted only 16U for Eaton MX Frame e LCD multilingual display with mimic and LEDs for rapid view of the UPS status diagnostics and event log e Outputs IEC 10A and 16A outlet sockets and hardwired outputs Built in Powershare system for remote reboot of the equipment connected sequential start up or load shedding while operating from battery to maintain the power to critical loads e Eaton MX Frame is compatible with three phase or single phase supplies e Backup time 10 mins up to 2 hours by adding 3U battery extension modules Minimum total cost of ownership TCO e More power with an output power factor of 0 9 e Eaton MX Frame is a modular system with 5 KVA sub modules paralleled to provide up to 20 kVA or 15 kVA with redundancy Technology Series 9 Double Conversion On Line Advanced protection for Rating 5 20kVA Scalable r Voltage 220 240 380 415 Vac 50 60 Hz a i a Backup time Typical 5 33 min internal extendable e Server clusters up to several hours Configuration Rack Tower convertible Pay as you grow The system rating can be easily scaled in 5kVA increments as your power requirements increase The MX frame is a modular system with 5kVA sub modules paralleled to provide up to 20kVA or 15kVA with redundancy Continuous power supply e Two front access hot swappables sub modules power and battery for ma
13. Mon Fri 2 Next Business Day response by Eaton Technician Authorised Agent for hardwired Eaton UPS gt 3kVA excludes Eaton 9155 amp MX Frame UPS to attend to fault is only applicable for locations within 100kms of Eaton Service Locations and or Service Agents Nationwide Additional travel charges apply for areas outside this range Includes basic disconnect re connect of UPS power tails as required Please contact your Eaton Representative for travel charges for a selected area 3 Disposal collection will take place during the time of delivery of a new unit or next business day Clients are to have Eaton products appropriately packaged and ready for collection to avoid additional transport charges 4 Initial Startup and Annual PM visits to be conducted during normal business hours and scheduled accordingly upon request from the customer Upon completion of the warranty registration customers will receive an email notification with our service center details requesting for scheduling to be made Customers will also be advise for PM visits to be scheduled within 8 9 months from date of installation 5 All Eaton UPS systems must be installed and operated in accordance with manufacturers documented operating procedures Failure to adhere to these procedures may void warranties 6 ESP registration can be done via the Eaton website at the register a product warranty portal Registration will be required within 30 days from date of ESP p
14. Output Voltage Maximum correction time 30msec 40 144V Superior High amp Low Line Performance Typical Model 200 or 210 Performance Features and Benefits e Superior Low Line Performance Specified performance is maintained for all loads 0 100 of nominal rating e Switchmode Computer Load Compatibility Able to support typical computer loads when input supply mains voltage is 50 below nominal e 240 Volt 230 Volt or 220 Volt Models Separate models to suit different nominal supplies or particular nominal output voltage requirements e 200 Overload Rated Suitable for use with computer start up overloads Units are output short circuit proof e On Site Configuration 7 5 to 18kVA units can be site configured as Single Phase or Three Phase operation if required e Selectable Voltages Hardwired 26 Series units have selectable input and output voltages e 5 Year Warranty Exceptional MTBF Mean Time Between Failure an optimum combination of performance to cost effective power conditioning www eaton com powerquality 1300 UPS UPS 65 500VA to 2500VA Portable Power Conditioners Designed and manufactured in Australia the Sola 200 210 portable Ol a 2 O 0 2 10 power conditioner provides smooth stepless control of output voltage to your computer or electronic system whilst attenuating harmful impulses surges and other power line disturbances The Sola 200 210 incorporates improved surge withstand capabilities
15. The double conversion architecture incorporates rectifier and inverter stages to completely isolate the output power from all input anomalies By adapting to a wide range of input voltages the E Series DX avoids battery usage during minor power fluctuations saving its capacity for times when utility power is completely lost Ideal for protecting e Computers and Peripherals e POS Equipment e PLC Systems e Security Systems 3kVA rear panel EATON CORPORATION UPS and Power Quality Products Catalogue Essential series 9 Power Protection Eaton E Series DX Technical specifications Capacity VA Watts 1000VA 700W 2000VA 1400W 3000VA 2100W 6kVA 4 2kW 10kVA 7kW 10kVA 7kW 15KVA 10 5kW 20kVA 14kW Standard Model EDX1000HA EDX2000HA EDX3000HA EDX6000HA EDX10000HA N A N A N A Internal Battery XL Model Large Charger N A N A EDX3000HXL EDX6000HXL EDX10KHXL EDX10KHXL31 EDX15KHXL31 EDX20KHXL31 External Battery Input Output Nominal Input Voltage 220 230 240Vac 1 Phase 240V preset on A models 230V on others 380 400 415Vac 3 phase Input Voltage Window 160 5V 296 5V at gt 80 load 176 276Vac at full load full load 50 60Hz Tolerance 46 56 0 5 Hz Low 54 64 0 5 Hz High Input Power Factor Frequency amp Frequency Range Nominal Output Voltage 220 230 240V 240V preset on A models 230V on others Output Voltage on 220 230 240V 240V preset on A models 230V on others Bat
16. and the user gets a notification of improper battery operation If it drops below this limit after the 10 day period charging is resumed without alarm In short the algorithm uses three charging stages in its operation Thus the batteries experience much less stress than in the case of traditional charging A typical battery charging cycle without power interruptions is shown in the graph below 15 00 UPS w ABM UPS w Trickle Charge ET e Qa 8 12 00 3 0 Alarm level x o Rue ov OG 2 a 900 Dg lt b gt E WE m 6 00 pa 0 12 18 24 30 36 42 48 54 60 66 72 Battery Age in month ABMO technology significantly increases battery service life www eaton com powerquality 1300 UPS UPS 9 10 Energy Advantage Architecture Energy Saver System Energy Advantage Architecture EAA The rising demand for highly available reliable and efficient power is a continuous challenge for data centre operators Higher energy efficiency helps to address increasing environmental regulatory and economic pressures Eaton has developed innovative and proprietary technologies that improve system efficiency without compromising on reliability under the Energy Advantage Architecture EAA umbrella Energy Saver System ESS is one of these technologies Maximised energy efficiency With 85 reduction in UPS energy losses ESS technology dramatically reduces energy consumption environmental impact and power costs without
17. cold aisle containment solution with or without a down flow chimney system e Increased ROI Modular building block design offers complete flexibility and room for growth increasing your initial Return on Investment ROI Features and Benefits e Variety of Door Models Choose from three styles of doors Single swing double swing caf style and sliding doors e Ease of Installation Field installable rack integrated and freestanding options available Rack Agnostic Flexible enough to install almost anywhere on any manufacturer s brand enclosure Improve Efficiency and Predictability Increases cold air intake efficiency from the bottom of the enclosure to the top within the cold aisle e Minimise Air Re mixing Cost effectively minimise air mixing between the hot and cold aisle while keeping the uniform cold air supply in front of the servers for a consistent temperature top to bottom Shown above Independent Containment System featuring End Of Row Cafe style doors and vertical blanking panels to accommodate third party enclosures www eaton com powerquality 1300 UPS UPS 55 56 Airflow management and racks Rack containment Eaton Heat Containment System HCS Eaton s HCS is a simple scalable and low cost solution to cool up to 25 kW or more per enclosure without the expense of adding supplemental CRAC units to your data centre This patented technology is available on Eaton s Paramou
18. compromising load protection Those outstanding energy savings typically recovers 100 of the UPS cost over a 3 5 year period No compromise on reliability In ESS mode the UPS safely provides mains current directly to load when the input is within the acceptable limits by its voltage and frequency If input power goes outside the preset limits by frequency or voltage the UPS switches to double conversion If input power is outside the tolerances of the system the UPS draws power from available battery modules Superior detection and control algorithms continuously monitor incoming power quality and allow the UPS to engage power converters in less than two milliseconds time when utility source goes out of pre defined limits by its voltage or frequency thus always providing secured power to the critical load while maximising efficiency In case of UPS detecting a fault condition while operating in ESS the UPS is capable to detect and determine whether the fault is caused by load or if it is upstream from the UPS A fault at the bypass source results in immediate switchover to the inverter a fault in the load keeps the UPS in Energy Saver System Proven Eaton technology ensures reliability and continuous load availability without compromising the protection of the supported equipment ESS allows for market leading 99 percent efficiency across the entire operating range Compared to conventional eco mode capabilities ava
19. increasing their efficiency by operating at a higher Delta T AT centre freeing up stranded assets and lowering operational costs locations and it is also field installable on third party enclosures HCS for third party racks Converting existing enclosures to the HCS allows you to eliminate the incremental capital expense associated with having to add more CRAC units or other supplemental cooling Features and benefits e Implement heat containment operations by building up from existing enclosures without having to re route or disconnect cables and power e By isolating the hot exhaust air from the cold supply air you can load over 25 kW of equipment in an enclosure Requires no additional air conditioners or other space consuming supplemental equipment at the perimeter of the data centre in row or overhead e Eliminates chaos airflow results in a more predictable operating environment allowing you to drive efficient energy use and create a reliable infrastructure for moves additions and changes Eaton s P Series enclosure with integrated HCS The HCS allows for your existing cable management without the interruption of re routing or disconnecting cables and power Shown here on Eaton s Paramount Enclosure System Optional fans 2 Chimney Tool less fan access door Chimney base EATON CORPORATION UPS and Power Quality Products Catalogue Airflow management and racks Enterprise class racks
20. line loss of 3 ie msec 2000 2605 2000M e CNC machinery e Programmable logical controls PLC e Photographic equipment e Entire installations 162 170 244 244 244 244 Typical Single Module Arrangement 68 EATON CORPORATION UPS and Power Quality Products Catalogue Support Tools and Programs Available E dm EASY KE WARD E FOR ME WHER DO 1 SIGN UP or r I gt KOLN al i et or a Power Quality Sales Web PQ Salesweb is a password protected website that contains Power Quality product information for Eaton channel partners of Eaton s power quality product portfolio The website has news product information marketing and sales tools you can benefit from in your daily Eaton sales To register go to website www pqsalesweb eaton com Access is granted upon approval of registration Eaton s PowerAdvantage rewards program Bigger rewards Better support Eaton s PowerAdvantage rewards program is an easy to use points based program which gives you access to a selection of over 3 000 fantastic products and experiences How does it work It s easy The more Eaton products you sell the more points you earn and the closer you get to some great rewards For more information once registered login to powerqu
21. mode 98 in Hi Efficiency Up to 95 in Online mode 98 in Hi Efficiency mode mode Crest factor short circuit current 3 1 90A 3 1 120A 3 1 150A Overload capacity 102 110 120s 110 125 60s 125 150 10s gt 150 500ms 102 110 120s 110 125 60s 125 150 10s gt 150 900ms Connections Input 1 1 Models Input 3 1 Models Qutput 1 1 Models Terminal block up to 10 mm Terminal block up to 16mm Terminal block 2 controlled groups of 4 IEC C13 10A 2 IEC C19 16A Terminal block up to 16mm Terminal block Qutput 3 1 Models Terminal block Qutput with optional HotSwap Maintenance Bypass 1 1 Models Terminal block 3 IEC C13 10A 2 IEC C19 16A Terminal block 4 IEC C19 16A Qutput with optional HotSwap Maintenance Bypass 3 1 Models Terminal block 4 IEC C19 16A Batteries 1 1 Models Typical backup times at 50 and 70 load 9PX 8 amp 11 KVA 1 Power Module 1 EBM 11 8 min 20 15 min 13 9min 9PX 1 EBM 8 amp 11 kVA Total 2 EBM 48 34 min 48 32 min 32 21 min 9PX 4 EBM 8 amp 11 kVA Total 5 EBM 170 120 min 140 100 min 100 70 min Batteries 3 1 Models Typical backup times at 50 and 70 load 9PX 6 8 amp 11kVA 1 Power Module 1 EBM 30 20min 20 15 min 13 9min 9PX 1EBM total 2 EBM 70 45min 48 32 min 32 21 min 9PX 4 EBM total 5 EBM 210 140 min 140 100 min 100 70 min B
22. operating costs by monitoring and tracking consumption from rack to branch right down to the individual server e Easily identify physical branch sections and related breakers through Colour coded sections Accurate V W A and kWhr measurement enables analysis and tracking e Enables you to see what your servers are doing Complete control and understanding e Control your power distribution and consumption e Build knowledge base of what is going on e Switch sequence outlets and outlet groups as well as individually monitor you have complete control Switched ePDU Switched ePDUs give control to the Data Centre manager be able to remotely shut off or restart equipment and ensure that it starts up in the correct sequence with the correct delays e Switching on and off control of individual outlets together with cycling and sequencing of outlets branch circuits and the ePDU as a whole e Monitoring Highly accurate monitoring of the ePDU as a whole for V W A and kWhr Also monitor temperature and humidity in the rack via optional sensors e Control Monitor over Ethernet or via Advanced LCD screen on the unit control via Ethernet Communication protocols include HTTP HTTPS DHCP SNMP v1 and v3 SNTP SMTP Telnet IPv4 amp IPv6 Basic ePDU Designed for reliable and cost effective power distribution Basic ePDUs have the form factor and outlet choices to meet your needs Designed for the Data Centre Al
23. performance in depth knowledge of customer applications continuous innovations and world class services Eaton solutions have been recognised by UPS users and industry experts for delivering highest customer value and satisfaction as well as for demonstrating most insight into customer needs among all UPS vendors Frost amp Sullivan Award for Customer Value and Satisfaction and Frost amp Sullivan Award for Product Line Strategy Eaton product and service range e AC UPS from 550VA up to 3500 kVA e DC systems of all sizes broad portfolio of rack based power distribution units ePDUTM e IT rack enclosures airflow management and heat containment systems e Software and connectivity products for power management and remote control e Technical support and maintenance e Complete power quality solutions Eaton products are manufactured in factories located in Finland USA China Taiwan India Morocco and New Zealand www eaton com powerquality 1300 UPS UPS 5 6 UPS Solution Overview Eaton s power management solutions are based on protecting the nine most common power problems present in any environment This unique approach makes your product selection decisions about power protection much simpler The nine power problems listed below are potentially harmful to both your data and your hardware Eaton s products offer three levels of power protection Series 3 Series 5 and Series 9 Based on t
24. s SA so US output remains within three percent of nominal voltage With a wide input voltage range the 9130 does not depend on batteries to smooth e Extended warranty plans out minor power fluctuations Batteries are conserved for those times when utility power is highly unstable or completely out If an outage occurs the 9130 transfers to battery with zero interruption in power making this an ideal UPS for sensitive and critical equipment e Mini Slot connectivity cards More real power for less cost High 0 9 output power factor enables the 9130 to provide its full power capability to modern IT equipment that may have a wide range of leading and lagging power factors With a 0 99 input power factor this UPS avoids the disturbances that some energy converters tend to cause Typical applications LF e Servers networking gear e Telecommunications VolP security systems e Medical systems e Diagnostics and medical screening e Patient record archives e Manufacturing systems e Chip fabrication e Pharmaceutical production e Chemical processing 32 EATON CORPORATION UPS and Power Quality Products Catalogue Premier series 9 protection for low density IT rack environments Faton 9130 Rack Technical Specifications Rating 1000VA 1500VA 2000VA 3000VA Part number PW9130G1000R XL2UAU PW9130G1500R XL2UAU PW9130G2000R XL2UAU PW9130G3000R XL2UAU Capacity VA Watts 1000 900 1500 1350 2000 1800 3000 2700
25. upstream and downstream switchgear Technology Series 9 VA Rating 200kVA 1100kVA at 0 9 p f Voltage 230 400 VAC 50 60Hz ce Backup 5 60 min An Eaton Green Solution Configuration Cabinet The Eaton 9395 uninterruptible power system UPS is a double conversion UPS that resolves all utility power problems and supplies clean continuous uninterruptible power to connected equipment Whether you re selecting a UPS for a branch office manufacturing floor medical facility or a large data centre there s a 9395 model that delivers just the right combination of performance and price for your needs Taking large system mission critical reliability to the next step The 9395 combines the reliability and redundancy of a multi module UPS into an integrated pre wired solution Built with up to 275 kVA building blocks the 9395 features N 1 internal redundancy which allows one 275 kVA module to automatically carry the load in the event the other module is out of service Advanced design delivers unequalled power performance The innovative design of the 9395 delivers the industry s best performance combination of efficiency input current distortion and power factor The 9395 operates at a high efficiency of up to 99 reducing utility costs and extending battery runtimes Higher system efficiency produces cooler operating conditions which reduces facility air conditioning cost extends the life of UPS components and increases overal
26. with Booster Fader Input voltage range 175V 275V Output voltage 240 V Frequency 50 60 Hz autoselect Connections Number of AUS outlets 6 Outlets with surge protection 3 3 and battery backup Outlets with surge protection only Batteries Typical backup times at 50 and 10 6 min 9 5 min 9 5 min 9 5 min 9 5 min 70 load Battery management Automatic battery test deep discharge protection cold start capable replaceable batteries Communication User Interface LED LCD Communication Port HID compliant USB port for automatic integration with most common operating systems Windows Vista 7 amp 8 Linux Mac OS X cable supplied Data line protection Tel Fax Modem Internet and Ethernet Standards Safety amp EMC IEC EN 62040 1 IEC EN 62040 2 CB Report CE mark C Tick Dimensions and Weight Dimensions H x W xD 250 x 87 x 260 mm 250 x 87 x 382 mm Weight 4 96kg 5 98kg 6 50kg 9 48kg 11 08kg Customer Service and Support Warranty 2 years warranty including batteries Part Numbers 550 700 850 1200 1600 5S 5S550AU 5S700AU 5S850AU 5 1200AU 5S 1600AU Battery run times are approximate and may vary with equipment configuration battery age temperature etc www eaton com powerquality 1300 UPS UPS 17 18 Superior series 5 performance Eaton 5SC Technology Series 5 Line Interactive Rating 500 1500VA Voltage 230 Vac Bac
27. your UPS they provide end to end power management for maximum uptime and data integrity Intelligent Power Manager software for extensive monitoring 13 and management Intelligent Power Protector and UPS Companion protection software provides graceful automatic shutdown of network devices during a prolonged power disruption preventing data loss and saving work in progress As part of Eaton s power network management system these two applications work together to deliver comprehensive power management and protection Intelligent Power Protector and UPS Companion shutdown software for extended power outages e Helps you avoid data loss by gracefully shutting down computers and virtual machines servers powered by an Eaton UPS during an extended power outage e Easy to use interface from any PC with a Web browser e Acquires UPS information through local or network communication and can be easily deployed on many computers e Can be remotely managed configured and updated with Eaton s Intelligent Power Manager e Can communicate with the protected device directly via USB or through the network via Web SNMP card Benefits for Virtualised Environments Intelligent Power Manager s Integration with vCenter helps data centre managers reduce infrastructure and operating costs while increasing productivity and operational responsiveness Intelligent Power Manager triggers vcenter s vMotion and SCVMMSs Live Migration application
28. 0 for 5 sec 125 for 1 min online 1000 for 5 msec bypass Overload capacity Efficiency 92 with computer load 93 with linear load LCD display Graphical LCD with blue backlight English German and Spanish languages extendable LED 4 LED for notice and alarm Standard communication ports 1 x RS232 for local support 2 x X Slot empty 1 x relay contact 1 x emergency power off input 2 x environmental input Optional External battery cabinets isolation transformer external mechanical bypass switch X Slot Web SNMP Modbus Jbus relay card RS232 port Hot Sync card www eaton com powerquality 1300 UPS UPS 45 Premier Rack Mount 3 Phase UPS for Data Centre amp IT Applications BI d U PS Typical applications aton a e Data centres with rack mount blade servers e Telecommunications Product highlights e Minimum efficiency of gt 98 in normal operation e Easy to install configure and deploy e Fits into standard 19 rack cabinets Hot swappable battery and electronics modules e Parallel for capacity redundancy e Hot Sync redundancy e Decentralised bypass ensures no single failure point ABM prolongs battery life by up to 50 Options e X Slot connectivity options Technology Double Conversion On Line On Demand i Rating 12 to 60 kW N 1 using 12 kW modules o ee Voltage 400 Vac 50 60 Hz Backup time 5 minutes typical extendable Configuration Rack mount Eaton BladeUPS i
29. 10A Rack 4 x IEC C13 10A 10A Rack 6 x IEC C13 10A 10A Rack 6 x IEC C13 10A Tower 2 x 10A AU individually Tower 2 x 10A AU individually Tower 2 x 10A AU individually Tower 2 x 10A AU individually switched switched switched switched Rack 2 x IEC C13 10A Rack 2 x IEC C13 10A Rack 2 x IEC C13 10A Rack 2 x IEC C13 10A individually switched individually switched individually switched individually switched Batteries Typical backup times for 50 and 70 load 9 5 5 mins 12 7 5 mins 12 7 5 mins 13 8 5 mins ABM amp Temperature compensated charging method user selectable Automatic battery test deep discharge protection to Battery management ti i attery manageme automatic recognition of external battery units 1 USB port 1 RS232 serial port and relay contacts USB and RS232 ports cannot be used simultaneously I mini terminal block for remote ON OFF or Remote Power Off Communications card slots 1 slot for NETWORK MS MODBUS MS or RELAY MS cards Operating conditions standards and approvals Operating temperature Models 650 850 amp 1550 0 C to 35 C Model 1550 0 C to 40 C Noise Level lt 40dBA Performance Safety EMC IEC EN 62040 1 1 Safety IEC EN 62040 2 EMC IEC EN 62040 3 Performance C Tick Approvals CE CB Report TUV C Tick Dimensions W x D x H Weight F R eel ee 150 x 345 x 230mm 7 8kg 150 x 345 x 230mm 10 4kg 150 x 345 x 230mm 11 1kg 150 x 445 x 230mm 15 6kg
30. 148 211 266 Run time chart provides typical information Battery runtimes are approximate and may vary with equipment configuration battery age temperature etc Longer run times available with Extended Battery Cabinets Please consult your sales representative for information www eaton com powerquality 1300 UPS UPS Premier series 9 protection for low density IT rack environments Eaton 9130 Rack Technology Series 9 Double Conversion On Line Product highlights Rating 1000 3000VA e Offers premium performance with a 0 9 power factor and Voltage 208 240Vac 95 efficiency Configuration Rack mount e Increases battery service life and system uptime with ABMO battery ae charging technology The newest Eaton addition the Eaton 9130 UPS resolves utility power problems and delivers superior power protection for IT and networking equipment medical systems manufacturing process control or anywhere critical equipment and applications require clean continuous power e Ensures data and system integrity with Intelligent Power software e Enables prolonged runtime of essential equipment during power outages by allowing for orderly remote shutdown of non critical systems or processes Double conversion design for superior power protection The 9130 is constantly monitoring power conditions regulating both voltage and Options frequency p Even when presented with the most severe power problems this UPS
31. 192 x 340x460 192 x 340x460 260x717x570 260 x 717 x 570 EL 0 XL Models a i 4 192 x 340 x 460 260x717x570 260x717x570 260x717x570 260x717x570 260x717x 570 Weight Standard 34 5 35 5 16 90 35 93 38 39 XL kg E Series DX internal battery models runtime chart Crono FDX2000HA EDXSOOOHA EDXGOOOHA EDXTO000HA Battery backup times are approximate and may vary with equipment configuration battery age temperature etc www eaton com powerquality 1300 UPS UPS 27 Superior series 9 protection for critical applications 28 Eaton EX Eaton EX Rack Tower versatility Technology Series 9 Double Conversion On Line Rating 1000 3000VA Voltage 208 240Vac Configuration Rack mount Tower convertible Maximum availability e Topology double conversion on line UPS with automatic by pass and power factor correction e Powershare the Eaton EX output sockets are individually controlled to provide load shedding to maximise the backup time and provide remote reboot and sequential start up as standard Continuous power supply Hot swappable batteries The HotSwap MBP Maintenance By Pass module allows the UPS to be replaced without interrupting the power supply Long backup times 1 to 4 EXB battery units can be added to the Eaton EX The Eaton EX 3000XL has a built in super charger for extra long backup times Minimum total cost of ownership e Easy operation the LCD gives you access to a wide ran
32. 2 95 fama forsse ms 2 fana orses fam 2 ra fame forsse 360 rs amass orse fa 3 re fame forsse 5 as messer Sarson 505 Notes 1 For units with nominal Ph N voltage of 220V specify 44 as in 200 44 730 for 3 18kVA units and 24 as in 200 24 822 for 22 5kVA model For units with nominal Ph N voltage of 230V specify 25 for 3 18kVA units and 35 for 22 5kVA 2 Units fitted with WIP 15 plug and 4 x 10 15 Amp screw sockets 3 Units fitted with input terminal block and 4 x 10 15 amp screw sockets 4 To avoid nuisance tripping of input circuit breakers we recommend the use of D curve or motor start type circuit breakers Current rating should be at least one size larger than input current stated on unit data plate See manual or consult your sales representative for further details 5 Enclosure Sizes mm Size 1 600 H x 400 W x 440 D Size 2 995 H x 525 W x 550 D Size 3 990 H x 800 W x 550 D Size 4 1236 H x 800 W x 550 D 6 3 Phase loads to be star connected only Power Conditioners NOT to be used for Delta loads www eaton com powerquality 1300 UPS UPS 67 Multi Voltage Hardwired Power Conditioners for Industrial Applications Sola 26 Multivolt Frequently power transformers are incorporated with process equipment to provide specific voltages for sensitive equipment Unfortunately outside interferences will vary the output from these transformers causing the sensi
33. 240Vac Backup time Typical 5 min Ideal for protecting Configuration Powerboard style 14 2 ener 30 AS e Computers and peripherals e Broadband modems internet and TV Protection against power problems e The Eaton 3S UPS helps to protect your computer equipment in case of everyday events such as lightning strikes storms over demand on e IP telephony equipment e POS equipment the utility grid accidents and natural disasters knocking out power without warning Eaton 3S Technical specifications Rating VA W 550VA 330W 700VA 420W Model numbers 3S550AU 3S700AU Output connection 3 x Aust 3 Pin 10A outlets with battery backup and surge protection 3 x Aust 3 Pin 10A outlets with surge protection Characteristics Input voltage Output voltage Up to 161 284 V adjustable 240 V settable to 220 V 230 V or 240 V Frequency Input protection 50 60 Hz autoselect Resettable circuit breaker Features ECO Control No Line protection Tel fax modem internet Ethernet Battery Battery type Compact sealed lead acid replaceable Battery test Yes Cold start no mains power Yes Deep discharge protection Battery replacement indicator Runtime at 50 load Runtime at 70 load Communication Standards compliance Safety EMC EMC Dimensions and weight Dimensions Hx W xD Weight Warranty Warranty Yes Commun
34. 328 D 120 dB typical 140 dB max 2kHz to 1 MHz ke Input lead fitted with 15 Amp plug top all other units fitted with 10 Amp Output Harmonic Less than 3 THD on linear loads plug tops Distortion No greater than 5 on typical computer loads 5 Specific input leads and output sockets can be fitted to order Environmental Environmental o 0 to 95 non condensing wary Ses 66 EATON CORPORATION UPS and Power Quality Products Catalogue 3kVA to 22kVA Power Conditioners Sola 200 Specifications Voltage 220 230 or 240 Volt AC Refer Ordering Details for configuration options 10 20 40 ANSI IEEE C62 41 1980 A and B waveforms suppressed to safe levels 220 or 240 Volt AC 3 for 10 20 input 5 8 for 40 input AC on off switch Return to regulation envelope within 30 msec Continuous and smooth correction for input voltage fluctuations 200 of rated load for 10 seconds without damage 500 of rated load for 10 msec Electrical Noise Attenuation Transverse Mode 60 dB typical 80 dB max 4kHz to 20 MHz 120 dB typical 140 dB max 2kHz to 1 MHz Less than 3 THD on linear loads No greater than 5 on typical computer loads Dherating AMBION wna sm Frequency Input Voltage Range Protection Nominal Voltage Frequency Voltage Regulation Control Power Efficiency 90 Response Correction Time Dynamic Response Overloads Common Mo
35. 4 Hour Emergency Service Hotline AUST 1300 303 059 NZ 0508 697 378 ETN Powering Business Worldwide Eaton Australia Eaton Sales 1300 877 877 Eaton Service 1300 303 059 Eaton Industries Pty Ltd Electrical Sector 10 Kent Road Mascot NSW 2020 Australia 1300 UPS UPS 1300 877 877 www eaton com powerquality technology alliance el VMWare PARTNER Eaton New Zealand Eaton Sales 0508 328 6669 Eaton Service 0508 697 378 Eaton Industries Company Electrical Sector First Floor Enable House 106 Wrights Road Addington Christchurch 8041 NZ 0508 EATON NZ 0508 328 6669 www eaton com powerquality Due to continual product improvement specifications are subject to change without notice Printed in AUS 808PQ
36. 62 040 2 class A class B as option 4 kV IEC 61 643 UL 1778 and CSA 22 219 Operating temperature noise approvals guarantee 0 C to 40 C continuous 45 dbA 10 UL T V GS mark CB C Tick CE IEC 61 931 one year 11 1 Eaton MXs can be paralleled using ModularEasy 2 At 70 load 3 4 IEC C13 10A 2 m long cables for use with retention clips 8 cables for use with Eaton MX Frame 4 Frequency conversion for non paralleled units only 5 Economy mode 91 in normal mode 6 At 70 nominal rating with power factor 0 7 typical values after 3 charge discharge cycles with 3 5 years old batteries Weekly battery test without interrupting the load daily or monthly if required EXB compatible with 0 8 power factor loads 7 With Eaton MX Frame EXB 4 battery units 8 Solution Pac CD ROM supplied as standard 9 Applicable to US models 10 50 dbA above 5 kVA 11 Depending on the country see www eaton com powerquality Part Numbers MX Frame 15000 MX Frame 20000 Eaton MX Tower or rack mounting standard backup time MXF15KC05 MXF20KC05 Eaton MX EXB battery extension module M87103 Eaton MX EXB Rack Kit rail kit for 19 rack mounting M68002 1 with rack kit casters NMC card MXF15KC05 M68526 empty Eaton MX Frame 3 x M68524 3 x M68523 2 with rack kit casters NMC card MXF20KC05 M68526 empty Eaton MX Frame 4 x M68524 4 x M68523 www eaton com powerquality 1300 UPS UPS 41 Essential 3 Phase protection for IT a
37. BI EDX40K4EBI EDX40K4AUBI 815 470x710x1753 Eaton E Series DX 3 Phase Technical specifications m Toegenomen OO THD i lt 5 HE mode high 98 efficiency eee 2 EE Dual line input Supported LCD UPS status and operating instructions Input voltage output voltage current frequency charger voltage and current fault and warning display Type Maintenance free VRLA batteries Backup time Up to 15 min with internal batteries on 20 40kVA more with external batteries UPS operation status Battery Voltage 360 V 30x12 V 180 cells 20kVA Warning equipment 384 V 32x12 V 192 cells all oth del pe em Buzzer alarm and light double LED om i Rte 380 400 415 Vac L L 220 230 240 Vac L N RS 232 AS 400 RS485 service EPO interface for battery temperature sensor intelligent communications Three phase four wire ground rm fm Overload capability 125 10 minutes 150 1 minute Runtime for 20 40kVA UPS with internal batteries p f 0 7 typical IT server computer load 9Ah12V 2 x 30 Run time chart provides typical information Battery runtimes are approximate and may vary with equipment configuration battery age temperature etc www eaton com powerquality 1300 UPS UPS 43 Premier Three phase UPS for servers and industrial applications F t 93 D D Product highlights a ON e Hot Sync redundancy e ABM providing up to 50 longer battery life time Active input power factor correction PFC providi
38. Dimensions WxDxH mm 438x438x86 5 2U 438x438x86 5 2U 438x600x86 5 2U 438x600x86 5 2U Weight kg 16 0 19 5 29 0 295 Input connection IEC C14 10A IEC C14 10A IEC C14 10A IEC C20 16A Qutput connection 2 AUST 10A 2 AUST 10A 4 AUST 10A 4 IEC C13 10A 4 IEC C13 10A 4 IEC C13 10A 4 IEC C13 10A 3 AUST 10A 1 IEC C19 15A Operational 240Vac 200 208 220 230 selectable 700 1500VA 120 140 160 276 Vac at 33 66 100 0 7pf load 2000 3000VA 140 160 180 276 Vac at 33 66 100 0 7pf load Nominal input voltage Vac Input voltage range Operating frequency 50 60 Hz auto sensing tolerance 40 70Hz Input power factor 0 99 240Vac 200 208 220 230 selectable Nominal output voltage Qutput voltage regulation 2 Up to 130 for 10 seconds 130 150 for 2 sec 700 2000VA 90 online 93 High Efficiency Mode Overload capacity Efficiency 3000VA 91 online 93 High Efficiency Mode User interface LCD display LED Four LEDs UPS On UPS on Battery UPS on bypass Alarm LCD display showing both UPS meters and UPS settings RS232 and USB as standard on all models 1 Mini Slot for Network Card MS Relay Card MS or Network amp Modbus Card MS connectivity cards Standard communication ports Optional Environmental Operating temperature 0 C 40 C Storage temperature 15 C 40 C Altitude lt 3000 m Audible noise at 1 metre l
39. EN 36 FN 38 FN 40 3 Phase UPS ccasneaii 42 Eaton E Series Dvs 42 PIO 1 ES EE 44 Eaton BladeUPS nnssesesmmsssssseesseeevseeeseeesvesessesersseereeseessesssn 46 EG SE OE 48 EON og SE EE 50 Eaton Power Xpert 9395 Lanessensmmnnikenkhevmmeiieeiniede 52 Intelligent Power Distribution accecccscsssscsoccsssssssseeccessesssceseeees 54 Airflow management and racks rsrnvnvnvnnrnvnenvnvnvnvnvrnvnvnenvnvnens 55 Aisle COMENMEN uassvssseeerdera ee 55 Rack CONAN LS 56 Enterprise class racks csssssssscsescssscscssescscssseeesssscssesasesesseesasesaeenseees 57 Rack SST 57 Intelligent Power Software Suite ssscccsscssssssseccsssesssseseeee 58 Options to Manage and Monitor Your UPS ervrvrvrvrnrvnvnenen0 59 Eaton s Power Xpert ee eg EE 60 Power Management smsmsvvevsrsvrvevrvevrerrsrrrrrrrerenrrrsvorerrnrsrsvsrsvrnrnennn 61 Surge Protection Devices r rsrrnenvsvsvrvrvrnrnvnenenenvnvnnnnrnenenenennnenr 64 Surge Protection Equipment Overview swsrsrrnrnrsrnrsrnrnrsrnrsrsrnrsrnrnnn 64 Power Conditioners nenvrvrsrnvnvrnrnvnvnnrnvnvrernrnenenvrnrnennnnenenennsnenenener 65 Sola Power Conditioners rsrsrsrsrnrvrnrnrsrnrnrnvsrnrnrnrnrsrnrnrnrnvsrnrsrnrnvsrnrnnn 65 Sola 200 4 nee eee ete eee ne 66 Sla 0 67 Sola 26 Multivolt sssoronrvonrrorrnrrvererenrnervsvnverenerenvsnsvenerenenesvsnsvenevenssennen 68 SUP ee 69 SE EEE EN 69 EATON CORPORATION UPS and Power Quality Products Catalog
40. Eaton P Series enclosure system Our premier enclosure platform P Series not only supports an industry leading 1 000 kilograms of equipment in a fully welded frame but it is also designed to adapt to the ever changing requirements of the data centre through a scalable and modular approach Speed of deployment is essential to any company when considering time to market P Series modularity and building block design ensures quick reconfigurations and minimises downtime protecting your initial investment Features and benefits e Superior airflow control and management e Flexible platform allows for ever changing requirements protecting your initial investment e Industry leading weight capacity of up to 1 000 kilograms handles even the heaviest server equipment e Guaranteed compatibility with TIA EIA 310 D standard sized equipment e Eaton s patented Heat Containment System HCS cools up to 25 kW or more per enclosure without the expense of adding supplemental CRAC units to your data centre e Full complement of accessories to handle non rackmount devices e Industry leading cable access and management Eaton E Series enclosures Eaton s E Series enclosures provide high quality and advanced features at an affordable price Features and benefits e Lightweight but sturdy e Stylish contoured front door provides 2 649 22cm total open area Exceeds major IT equipment air flow requirements e Vendor neutral compatible with a
41. Output receptacles 2x ANZ 3 pin 10A sockets 3 x ANZ 3 pin 10A sockets Input Connection Fixed 1 5M 10A ANZ 3 pin input cord included Battery run time minutes Typical backup times for 1 PC 16 20 45 50 50 Typical backup times for 2 PC 6 8 20 26 26 Typical backup times for 3PC 7 10 10 Typical backup times for 4 PC 5 Start On Battery Unit can be started without being connected to AC utility power battery recharged is maintained even when UPS is off whilst connected to mains User Interface Visual 1 On Off Green LED button AC mode Steady on Battery mode flashing Audible Five audible alarms indicate operating modes refer user manual Communications management Power Management Software Eaton UPS Companion power management software downloadable via internet Connection Type 1 x USB port to front panel Approvals CE Marking C Tick Dimensions and weights 10 5 kg Warranty 12 Months Warranty Optional warranty uplifts Battery run times are approximate and may vary with equipment configuration battery age temperature etc 16 EATON CORPORATION UPS and Power Quality Products Catalogue Superior series 5 power protection for office servers Eaton 5 S The Eaton 5S UPS provides effective power protection even in disturbed electrical environments Voltage fluctuations are automatically corrected using an AVR device booster fader without needing the batteries The 5S not only provides a supply with battery bac
42. UPS Dimensions mm amp weight 438 x 364 x 43 2mm 1RU 438 x 509 x 43 2mm 1RU 438 x 509 x 43 2mm 1RU 438 x 554 x 43 2mm 1RU kg Rack 8 6kg 13 8kg 14 6kg 19 4kg Customer Service amp Support Warranty 3 years on electronics 2 years on batteries Part Numbers 5P Tower 5P650AU 5P850AU 5P1150AU 5P1550AU 5P Rack 5P650iR 5P850iR 5P1IBOR Runtimes are shown at 0 7 power factor Backup times are approximate and may vary with equipment configuration battery age temperature etc Communication ports www eaton com powerquality 1300 UPS UPS 21 Superior series 5 protection for low density IT tower and rack applications Eaton 5130 Technology Series 5 Line Interactive Options Rating 1250 3000 VA e Extended Battery Modules for longer run times Voltage 230 Vac Configuration Rack mount Tower convertible SNE e Extended warranty plans The 5130 resolves outages sags surges under voltage and over voltage conditions and supplies regulated power to all connected equipment This UPS is particularly well suited for protecting e IT and networking equipment such as routers switches servers wireless devices storage systems security systems and PC workstation clusters e Telecom equipment such as PBXs VoIP components and EDGE 3G WiMAX wireless networking equipment The 5130 is value priced but it delivers features you would normally expect to find in much higher priced systems such as load segment co
43. When operating in ESS mode the load is protected with inherent surge suppression When utility power quality is high ESS can reduce UPS power losses by 75 as it runs on double conversion only when needed The Eaton 93PM UPS is a high power density solution In a footprint of just 0 5 m2 it can provide full rated power and standard backup time with internal batteries Eaton s advanced charging algorithm prolongs battery service life significantly compared to traditional charging methods Automatic battery tests ensure any defects on batteries are detected and any failed blocks replaced on time Battery health data is available for viewing easily EATON CORPORATION UPS and Power Quality Products Catalogue through the display By being able to monitor the condition of batteries and view a history log of test data system maintenance can be better planned and scheduled ahead Typical applications e Data centres with rack mount blade servers e Telecommunications Product highlights e 96 7 efficiency in double conversion e gt 99 efficiency with Energy Saver System ESS e Standard 10 20 minutes full load runtime with internal batteries e Intelligent Power Manager allows you to monitor and manage your UPS system as an integral part of power infrastructure e Plugs into leading virtualisation management systems like VMware vCenter Microsoft SCVMM and Citrix XenCenter e Display shows power quality energy consumption and efficien
44. a key component of Energy Advantage Architecture Eaton VMMS technology maximises UPS efficiencies at low load levels while supplying the load with continuous double conversion power Most UPS installations are only loaded between 20 40 but UPSs are not optimally efficient when used at these lighter loads Existing method for increasing load percentage The existing approach to capturing efficiency from low load levels applied only to multi UPS parallel systems The system can increase the effective load percentage by putting entire UPSs into idle While this helps improve efficiency slightly it is limited to multi UPS parallel systems and flexibility to adapt to the load can only be done in the large steps of full UPS capacity The VMMS way VMMS optimally employs UPMs to achieve higher efficiencies in double conversion mode in order to maximise the load level on remaining active UPMs by setting UPMs that are not needed to ready state This is calculated according to VMMS load threshold of the UPMs 80 by default and the system configuration redundancy requirements This results in maximised energy savings VMMS is possible thanks to Eaton Power Xpert 9395 UPS modularity and VMMS applies even in single UPS systems Upon a load increase on critical bus all ready state UPMs are able to react quickly and revert to double conversion mode in less than 2 ms by connecting the existing PWM signals to the IGBT gates system with Ea
45. al LCD display provides clear information on the UPS s status and measurements on a single screen in seven languages Enhanced configuration capabilities are also available with easy to use navigation keys Meters energy consumption and provides kWh values through the LCD and Intelligent Power Software Load segment control enables prioritised shutdowns of nonessential equipment to maximise battery runtime for critical devices Load segment control can also be used to remotely reboot locked up network equipment or to manage scheduled shutdowns and sequential start ups The 5P offers Serial and USB connectivity plus an extra slot for an optional communication card including SNMP Web card or relay contact card Eaton s Intelligent Power Software Suite compatible with all major OS including virtualization software such as VMware and Hyper V Is included with each UPS Performance and Efficiency With an optimised electrical design the 5P can provide up to 98 efficiency contributing to lower cooling and utility costs When operating in battery mode the 5P provides a high quality output signal for any sensitive equipment connected such as active PFC power factor corrected servers Availability and Flexibility 5P is available as a tower or rack form factor to cater for varied deployment applications Stronger longer battery life Eaton ABM battery management technology uses an innovative three stage charging technique th
46. ality eaton com pp login asp cx 22 click on Eaton Salesweb and then rewards program quicklink to access website To register go to website www powerquality eaton com and click on icon Please allow some time for your access to be granted Become an Eaton gj Partner ANZ Designer Tool kit Eaton s Designer Tool Kit is a valuable online resource for consultants where you ll find specifications for our Electrical Power Quality equipment If you re running a project based around one of our UPS systems our Designer Tool Kit will help you plan it To register go to website www powerquality eaton com click on icon g er ToolKit NATSPEG NATSPEC manages a comprehensive national specification system endorsed by government and professional bodies NATSPEC the National Building Specification is for all building structures with specialist packages for architects interior designers landscape architects structural engineers service engineers and domestic owners AUS SPEC is the Local Government specification system for the life cycle management of assets Packages include Urban and Open Space Roadworks and Bridges Public Utilities and Maintenance NATSPEC is also responsible for the National BIM Guide and its associated documents Eaton is an approved NATSPEC Partner To download Eaton s branded worksection www natspec com au Products_Services branded_ws asp A branded worksection is a technical worksection produced in NATSPEC format in conjunc
47. at only recharges the battery when necessary so the battery experiences less corrosion and service life is prolonged by up to 50 Batteries can be hot swapped without ever having to shut down connected equipment With an optional hot swap maintenance bypass module you can even replace the entire UPS Advanced protection for e Servers e Switches e Routers e Storage devices EATON CORPORATION UPS and Power Quality Products Catalogue Premier high density series 5 protection for network devices Eaton 5P 1550 tower and rack 1 CGommunications card slot 2 Remotely switchable outlet groups 3 Remote On Off Remote Power Off terminal 4 USB Port 5 Serial Port 6 Primary outlet group 650VA 420W 850VA 600W 1150VA 770W 1550VA 1100W Tower or 1U Rack Line Interactive High Frequency Pure Sinewave Booster Fader 160V 294V adjustable to 150V 294V 47 to 70 Hz 50 Hz system 56 5 to 70 Hz 60 Hz system 40 Hz in low sensitivity mode 230 V 6 10 Adjustable to 200V 208V 220V 230V 240V 50 60 Hz 0 1 autosensing Tower Fixed line cord 10A Tower Fixed line cord 10A Tower Fixed line cord 10A Tower Fixed line cord 10A AU 1 8mtr Rack IEC C14 10A AU 1 8mtr Rack IEC C14 10A AU 1 8mtr Rack IEC C14 10A AU 1 8mtr Rack IEC C14 10A socket socket socket socket ce C13 Tower 2 x AU 10A 3 x IEC C13 Tower 2 x AU 10A 3 x IEC C13 Tower 2 x AU 10A 3 x IEC C13 10A
48. attery management ABMO and temperature compensated charging method user selectable automatic battery test deep discharge protection automatic recognition of external battery units Communication Communication ports 1 USB port 1 RS232 serial port USB and RS232 ports cannot be used simultaneously 4 dry contacts DB9 1 mini terminal block for remote On Off and 1 for Remote Power Off 1 DB15 for parallel operation Communication slot 1 slot for Network MS card ModBus MS or Relay MS cards Operating conditions standards and approvals Operating temperature 0 to 40 C continuous Noise level Safety lt 45dB 1 1 48dB 3 1 IEC EN 62040 1 UL 1778 1 1 CSA 22 2 lt 48dB 1 1 amp 3 1 lt 500B 1 1 amp 3 1 EMC performance IEC EN 62040 2 FCC Class A 1 1 IEC EN 62040 3 Performance Approvals CE CB report TUV UL 1 1 C Tick Dimensions H x W x D Weight UPS 440 19 130 3U 685mm 48kg 1 1 440 19 260 6U 700mm 84kg 1 1 440 19 260 6U 700mm 86kg 1 1 440 19 260 6U 700mm 88kg 3 1 440 19 260 6U 700mm 88kg 3 1 440 19 260 6U 700mm 88kg 3 1 EBM 440 19 130 3U 645mm 68kg 1 1 440 19 130 3U 680mm 65kg 440 19 130 3U 680mm 65kg 440 19 130 3U 680mm 65kg 3 1 Power module 440 19 130 3U 700mm 23kg 3 1 only 440 19 130 3U 700mm 19kg 1 1 440 19 130 3U 700mm 23kg 3 1 440 19 130 3U 700mm 21kg 1 1
49. bility e The new graphical LCD provides clear information on the UPS s status and measurements on a single screen in seven languages LCD display position can be adjusted to offer the best viewable angle for tower and rack usage e The 9PX can meter energy consumption kWh values can be monitored using the LCD or Eaton s Intelligent Power Software Suite Load segment control enables prioritised shutdowns of non essential equipment to maximise battery runtime for critical devices It can also be used to remotely reboot locked up network equipment or to manage scheduled shutdowns and sequential start ups 36 EATON CORPORATION UPS and Power Quality Products Catalogue Premier series 9 power protection for medium to high density rack environments Technical Specifications Rating kVA kW 6kVA 6kVA 5 4kW SkVA 8kVA 7 2kW 11kVA 11kVA 10kW Electrical Characteristics Technology On line double conversion with Power Factor Correction PFC system Input voltage range 1 1 models 176 276V without derating up to 100 276V with derating 3 1 models 305V 480V without derating up to 175V 480V with derating Output voltage THDU 200 208 220 230 240V 1 THDU lt 2 1 1 amp 3 1 200 208 220 230 240 250V 1 THDU lt 2 1 1 amp 3 1 Input frequency range THDI 40 70Hz 50 60Hz autoselection frequency converter as standard THDI lt 5 Efficiency Up to 94 in Online
50. ce Large LCD graphically displays UPS status and offers easy access to measurements controls and settings Connectivity With Eaton Mini Slot connectivity cards you can monitor manage and remotely shutdown UPSs across the network e Network Card MS Web SNMP Card allows you to connect your 93E UPS directly to the Ethernet network and the Internet e Network and MODBUS Card MS provides remote monitoring of a UPS system through a Building Management System BMS or Industrial Automation System IAS e Relay Card MS enables provides the essential dry contact interface between your Eaton UPS and any relay connected computer as well as a variety of industrial applications Software Eaton s Intelligent Power Software Suite incorporates two important applications for ensuring quality power and uptime monitoring and management of power devices across the network combined with automatic graceful shutdown when faced with an extended power outage e Monitor and manage multiple power devices across your network e Extend the uptime of dual powered servers with redundancy capabilities e Enable server shutdown and live migration events To learn more please visit www eaton com intelligentpower Applications e Small to medium data centres e Corporate e Telecom e Healthcare e Banking e Industrial e Education Government Essential protection for Data Centre and Industrial applications Faton 93E Technical Specificatio
51. cy trends e Data logging feature allows easy measurement monitoring and managing Options e Variety of connectivity card options e Environmental Monitoring Probe e Extended runtimes with line and match external battery cabinets e External maintenance bypass wall mountable e System Parallel Modules Door LEDs provide at a glance status indication e Energy Saver System An Eaton Green Solution Premier modular protection for high availability systems Eaton 93PM Technical Specifications General UPS output power rating 1 0 p f Efficiency in double conversion mode Efficiency in Energy Saver System ESS Field upgradeable Inverter rectifier topology Audible noise 30 40 50 80 100 120 150 160 200 kW Up to 97 gt 99 Yes Transformer free IGBT with PWM 30 50 kW lt 60 dBA 80 200 kW lt 65 dBA ESS operation lt 47 dBA Altitude max Input wiring Nominal voltage rating configurable Input voltage range Input frequency range Input Power Factor 1000 m without derating max 2000 m 3ph N PE 220 380 230 400 240 415 V 50 60 Hz High 20 rectifier input 10 bypass input Low 15 at 100 load 40 at 50 load without battery discharge 40 72 Hz 0 99 Input ITHD Soft start capability Internal backfeed protection Battery Battery type Charging method Temperature compensation Battery nominal voltage VRLA Charging current maximum Ba
52. de Output Harmonic Relative Humidity The extension of Sola ferroresonant power conditioners continues through to 22kVA These units are mostly suited to hardwired fixed installation applications for providing smooth stepless control of the output voltage attenuation of harmful impulses or surges and other power line disturbances Sola 200 power conditioners are ideally suited to provide protection in computer rooms regulation for scientific instrumentation plus protection and regulated power to sophisticated computer based factory process equipment To simplify installation all units are free standing and fitted with castors excluding 22kVA and jacking feet Connections are provided at the rear via a base plate cable entry to an isolation switch The flexibility of Sola 200 power conditioners is increased on units between 7 5kVA and 18kVA These units can be field configured for single phase or three phase operation Sola 200 power conditioners 3 to 22kVA incorporate approved surge withstand capabilities as required by ANSI IEEE C62 41 1980 Built to protect Remote computer peripherals copiers and laser printers process control equipment CNC machinery programmable logical controls PLC photographic equipment and entire installations Ordering details Configuration Enclosure Size Note 5 kVA far Phase ony fo waoe Phase only 100 5 faar Phase only 155 2 Part Number 5 wano isoon 155
53. eans Eaton products and services meeting the environmental standards of this p process earn the Eaton Green Leaf label Though all of our products helping gul customers utilise electrical power are designed to meet government standards and public expectations more efficiently while significantly improving for protecting the environment Green Leaf products and solutions go well beyond normal standards to provide exceptional benefit to our environmental performance customers and the environment We also care for the way our parts and materials are supplied Eaton is a part of Green Suppliers Network a network that helps its component suppliers to develop Lean and Clean manufacturing processes that result in reduced waste and saved money all while reducing their impact on the environment For more information on how Eaton is Sustainable by Design please visit www eaton com sustainability a An Eaton Green Solution 4 EATON CORPORATION UPS and Power Quality Products Catalogue About Eaton s Solutions Eaton offers the largest selection of power management and protection solutions available in the industry From the desktop to the data centre from AC powered to DC powered equipment Eaton is your one stop partner for all your power needs Eaton s Power Quality solutions provide the confidence that power problems will not disrupt your systems data and operation Delivered through more than 50 years of solid
54. ecifications 1500 Rating VA W 1500VA 1350W 2000VA 1800W 2200VA 1980W 3000VA 2700W Format RT2U rack tower 2U RT2U rack tower 2U RT2U rack tower 2U RT2U amp RT3U Electrical characteristics Technology Line Interactive High Frequency Pure Sinewave Booster Fader Input voltage and frequency ranges 160V 294V adjustable to 150V 294V 47 to 70 Hz 50 Hz system without using batteries 56 5 to 70 Hz 60 Hz system 40 Hz in low sensitivity mode Qutput voltage and frequency 230 V 6 10 Adjustable to 200V 208V 220V 230V 240V 50 60 Hz 0 1 autosensing Connections Input 1 IEC C14 10 A socket 1 IEC C14 10 A socket 1 IEC C20 16 A socket 1 IEC C20 16 A socket Qutputs 8 IEC C13 10 A 8 IEC C13 10 A sockets 8 IEC C13 10 A sockets 1 IEC C19 16 A socket 8 IEC C13 10 A sockets 1 IEC C19 16 A socket Remotely controlled sockets 2 groups of 2 x IEC C13 10 A Additional outputs with Hot Swap MBP 4 AUS 10A 1 IEC 16A sockets or 6 IEC 10 A sockets or terminal blocks HW version Additional outputs with FlexPDU 6 AUS 10A 1 IEC 16A sockets or 12 IEC 10 A sockets Batteries Typical backup times for 50 and 70 load 5PX 19 11 mins 16 8 mins 15 8 mins 14 9 mins 5PX 1 EBM 90 54 mins 66 39 mins 60 35 mins 66 38 mins 5PX 4 EBM 285 180 mins 231 138 mins 210 125 mins 213 131 mins Battery ma
55. ected equipment With an optional hot swap maintenance bypass module you can even replace the entire UPS e There is also the possibility to add more runtime with up to four external hot swappable battery modules able to run systems for hours if necessary The additional battery modules are automatically recognised by the UPS Ideal for protecting e Servers e Switches Routers e Storage devices Technology Series 5 Line Interactive Rating 1500 3000VA Voltage 230 Vac Configuration Rack mount Tower convertible The Eaton 5PX provides exceptional efficiency manageability and metering capabilities for IT managers Manageability e The new graphical LCD display provides clear information on the UPS s status and measurements on a single screen in seven languages Enhanced configuration capabilities are also available with easy to use navigation keys e For the first time in the industry the 5PX can meter energy consumption right down to the managed outlet groups kWh values can be monitored using the LCD or Eaton s Intelligent Power Software Suite Load segment control enables prioritised shutdowns of nonessential equipment to maximise battery runtime for critical devices Load segment control can also be used to remotely reboot locked up network equipment or to manage scheduled shutdowns and sequential start ups e The 5PX offers Serial and USB connectivity plus an extra Mini Slot for an optional communication card i
56. ective protection against damaging surges e The Ellipse ECO includes a high performance surge protection device that complies with IEC 61643 1 this device also protects data connections such as Ethernet internet and telephone lines Easy integration and installation e The Ellipse ECO comes with eight IEC outlets 1200 1600 models Two IEC to IEC and two IEC to Aust 3 pin adaptor cables supplied e The Ellipse ECO s extra flat design makes it easy to install in any office environment installation options include vertical box format below the desk horizontally under a monitor 19 rack mounted optional 2U kit and wall mounted optional kit e The Ellipse ECO is designed to be compatible with a wide variety of different computer models Eaton power management software is delivered as standard CD and USB cable supplied and is compatible with all major operating systems Windows 7 Vista XP Linux and Mac OS Complete peace of mind e Periodic battery self test ensures early detection of a battery that needs to be replaced e Easy to replace battery helps to extend UPS service life e Push button circuit breaker enables easy recovery from an overload or short circuit 1200VA 750W 1600VA 1000W Model Numbers EL1200USBIEC EL1600USBIEG Qutlets with surge and backup outlets with surge only Cables 4 4 IEC C13 10A 4 4 IEC C13 10A Input cable 1 x IEC IEC 10A output cable and 2 x IEC to Aust 3 Pin output adap
57. eights and row spacing It s self supporting structure allows for easy rack changes within the row Fire activated ceiling panels ensure quick row access for critical fire Suppression Independent Containment System ICS The culmination of Eaton containment strategies is its patent pending Independent Containment System ICS a free standing scalable sustainable and vendor neutral containment solution for high density computing environments Designed to provide maximum flexibility in all environments the ICS assembled within the footprint of a standard aisle is constructed with a tubular steel frame The frame s structure is designed to be freestanding and meets seismic NEBS Zone 4 standards Additionally it accepts a variety of Eaton s End of Row Doors including caf style swing and sliding models Features and Benefits e Scalable Design The ability to extend aisles with load growth makes the ICS an ideal solution for co location and other highly evolving data centre Design can support an overhead cable tray Containment Integrity Vertical blanking panels ensure airflow containment when racks are partially deployed within the row and are easily removed in sections to allow quick installation of new IT racks Rack Agnostic Ability to support virtually any brand of server or network rack in any depth height and size with on demand reconfiguration of the row e Cold Hot Aisle Compatible Easily deployed as a
58. emand measurements for 138 standard data points logged e At a glance view of power quality analysis with patented Power Quality Index gauge e Industry standard communication protocols to support a multitude of configurations and third party software HTTP FTP Modbus RTU Modbus TCP SNMP SMTP NTP COMTRADE e High storage capacity e ANSI C12 20 accuracy e CE certified Power Xpert Meter 2000 series Compact Power Quality Metering products The meters combine state of the art technology with waveform viewing data trending and performance benchmarking The embedded Web server enables users to surf to the meter over the Internet via a standard Web browser This platform offers adaptability such as field upgradeable firmware and optional digital inputs outputs and analog outputs Identify power quality problems to help Protect motors from damage e Preserve the integrity of processes and batches e Prevent blown capacitor bank fuses e Protect transformers and conductors from overheating IQ 250 260 series Metering products The IQ 250 and IQ 260 electronic meters provide capabilities you wouldn t normally expect in an affordable compact meter such as fast sampling rate and accurate metering for a full range of power attributes The meter can be configured either from the easy to read display or remotely accessible via a Power Xpert Gateway via included configuration software In addition built in slots allow f
59. en library interfaces monitor a multitude of different device types e Customisable graphic user interface GUI depicts any company or organisational topology in the initial design e Web browser access and remote notification enables easy system access without the need for additional client seat licenses EATON CORPORATION UPS and Power Quality Products Catalogue Power Management Energy Management System Upgrade Kit 42 circuits one panel or 84 circuits two panels 208 120V 380 220V 400 230V 415 240V Wall mounted standalone unit Monitoring Rating Configuration Millions of dollars a year are invested in power protection systems such as UPSs and generators but problems can still occur at the branch circuit level due to improper loading or inadequate monitoring You might not be able to see trouble coming until a circuit breaker trips and that s too late Systems go down Valuable data is lost and business comes to a standstill It can take hours to recover The EMS continuously measures the current on all breaker levels and warns you of impending trouble so you can take proactive steps Armed with these insights data centre and facilities managers can more effectively balance loads prevent overload conditions plan for future capacity needs and where applicable allocate energy cost among internal departments Extending the reach of the Energy Management System The EMS has always integrated with Eaton s
60. ending on style e EIA 310 D compliant for 19 equipment e Color black steel black plastic clear plastic e Available in tool less mechanically fastened clear and cable pass through styles Solid side panel A solid side panel kit qty 2 is available to further enclose your rack where end of row or single rack aesthetics is necessary Air Seal Kits Stop air leakage through small openings and gaps in the doors sides bottom or top of your enclosures Heavy duty fixed shelf Supports non rackmounted equipment Four point mounting and 400 pound weight capacity Environmental Rack Monitor Monitor Temperature amp Humidity at two points in a rack or small server room aswell as up to four contact sensor devices ie Water leak Vibration Door contact or Smoke www eaton com powerquality 1300 UPS UPS 57 58 Intelligent Power Software Suite EEE ok el ea I J e Eatons Intelligent V re ws g samme eee NN lap Bai p Saree ro dim pers fol vidt h ao quo Peek miii Power Software Suite Ge mes mua mm 2 a HETE MP kai D P bred a i Piei Fih iad uer E amp eth wht rae ATT 8 iat ere Incorporates two important applications for ensuring quality power H timi Utes as Fre e Ea ri Fs il 1 ia ahr wi and uptime monitoring and management of power devices across E 2 dte hore menter the network and automatic graceful shutdown when faced with an J summen veste
61. erms of replacement labour and shorter service cycle worn battery entails a risk of unexpected load loss In normal UPS operation back up power is needed only occasionally and the battery wearing rate depends strongly on how the full charge is being maintained Excess charging is detrimental under any operating circumstances Eaton has created ABMO Technology to extend the life of valve regulated lead acid batteries by applying sophisticated logic to the charging regime Using traditional trickle charge method batteries become subject to electrode corrosion and electrolyte dry out especially in standby service use due to continuous float charging ABM is essentially an addition of intelligence to the charging routine by preventing charging when it is not necessary thus significantly retarding wear out ABM provides an additional feature for monitoring battery condition and advance warning about the end of battery life upon detection of a weak battery Also it optimises the recharge time which is advantageous when there may be consecutive power outages within a short period ABM has been used for over fifteen years in our UPSs ranging from 1 to 160 kVA and is now applied in UPS up to 1100 kVA ABMO cycle and operation how does it work The basic idea about ABM is to leave a fully charged battery in rest mode for most of the time and then apply charge current only at certain intervals Initially in order to charge up a f
62. ffordable power protection for your personal computers home office and other electronic devices While packed with valuable features such as ANZ power receptacles and USB communications the compact size is ideal for limited office and home working spaces Features e Automatic Voltage Regulation AVR stabilises fluctuating power sources e Microprocessor control design ensures high reliability e Up to three ANZ receptacles allowing easy equipment connection e User replaceable batteries allow easy maintenance e Start on battery provides portable power capability Technology Series 5 Line Interactive e Eaton UPS Companion software monitors power conditions and Rating 650 850 1100 1500 2000VA pee Voltage 230V gracefully shuts down computer applications prior to battery depletion Backup Time Typical 5 min e Intuitive LCD panel annunciates UPS status at a glance Configuration Tower Ideal for protecting e Computers and Peripherals e POS Equipment 650 850VA 1100 2000VA BE Series Technical Specifications Technology Line Interactive Automatic Voltage Regulation Rating VA Watts 650VA 360W 850VA 480W 1100VA 660W 1500VA 900W 2000VA 1200W Model Numbers 5E650IUSB AU 5E850IUSB AU 5E1100IUSB AU 5E1500IUSB AU 5E2000IUSB AU Characteristics input output Input Voltage Window 170 280 Volts Output Voltage on Battery 230V Frequency 50 60Hz auto detection
63. g tolerance 47 70Hz Nominal output voltage 230 Vac 200 208 220 240 Selectable Qutput voltage range 230V 6 10 User interface LED 13 LED s bar graph load battery charge level and various status and alarms Standard communication ports RS232 and USB as standard on all models Optional 1 Mini Slot for Network Card MS and Relay Card MS connectivity cards Environmental Operating temperature 1250VA 0 C 40 C 1750 3000VA 0 C 35 C Storage temperature 15 C 50 C Altitude lt 3000 m Audible noise at 1 metre lt 45dBA Certification Battery Runtimes in minutes Half Load Full Load Battery Backup Times in minutes Half Load Full Load Run time chart provides typical information Battery runtimes are approximate and may vary with equipment configuration battery age temperature etc www eaton com powerquality 1300 UPS UPS 23 Premier efficient amp manageable protection for high end IT applications Availability and Flexibility Eaton 5 PX e The 5PX comes in a rack tower convertible cabinet pedestal and rail kits are included with all models at no extra charge e Stronger longer battery life Eaton ABM battery management technology uses an innovative three stage charging technique that only recharges the battery when necessary so the battery experiences less corrosion and service life is prolonged by up to 50 e Batteries can be hot swapped without ever having to shut down conn
64. ge of measurements and set up menus Remote supervision the Eaton Intelligent Power software suite offers a wide range of communication option including SNMP and HTML ModBus JBus and relay outputs EATON CORPORATION UPS and Power Quality Products Catalogue Total flexibility Eaton EX has unmatched Flexibility e Format EX 1000 to 1500 are available in RT2U convertible rack tower format compatible with short depth rack EX 2200 amp 3000 are available in RT2U format optimised for rack mounting or RT3U for tower or short depth racks e Connections with FlexPDU and HotSwap MBP the RT2U and RT3U models can be connected by sockets or terminal blocks They can be installed as required on the side or on top of the unit e Compatible with high power factor loads Eaton EX is rated for 0 9 power factor 1000 VA 900 W 1500 VA 1350 W 2200 VA 1980 W and 3000 VA 2700 W e Communication the EX includes both serial and USB ports plus remote On Off connector and an extra slot for optional communication cards Ideal protection for e Servers data storage and network equipment e Telephony VoIP e Medical equipment Industrial processes Superior series 9 protection for critical applications w 1 x USB port 1 x serial port remote ON OFF and emergency stop inputs 1 LCD Multilingual display 6 languages displays measurements displays alarms access to control and set up menus 4 EXB battery uni
65. gical choice for the required trending analysis and alarming systems Power Xpert Software is Web enabled open and time synchronised Using only a browser you can access the software from anywhere your network can reach including remotely Designed to communicate graphically with the broad range of Eaton and non Eaton devices Power Xpert Software uses industry standard protocols The software is available in two editions Professional and Enterprise puin Fie E es E rmm m wm e Geared towards end users with built in support for Eaton power distribution products such as switchgear UPSs breakers PDUs RPPs meters relays VFDs and MCCs among others e Eaton products connect with the software directly via an Ethernet connection while legacy devices use a Power Xpert Gateway to Web enable their communications e A subset of third party meters and devices are supported as standard via the gateway connection Power Xpert Software Enterprise Edition e Geared towards advanced power users system integrators and enterprises with heterogeneous device spectrum and system developers who can take advantage of the included SNMP and Modbus integration development utilities e Extensive support for third party devices via standard SNMP and Modbus TCP protocols e Large variety of ready made third party drop in drivers Power Xpert Reporting Standard reports include Energy Summary Report Energy Cost A
66. he parameters defined by your application you can select an uninterruptible power system UPS from Power Power Sag Surge Power Failure Under voltage Over voltage Power Power Sag Surge Power Failure Power Failure Under voltage Over voltage Line Frequency Noise the series that best matches your power protection needs To provide maximum power protection Eaton offers a full line of Series 9 UPSs with both single phase and three phase models in the Series 9 family Within each Series Eaton has created 3 classes of products to provide Good Better and Best levels of features and performance and enable the best product fit for any application and budget AC to DC Rectifier DC to AC Inverter Battery F Buck Boost DC to AC Inverter Harmonic Distortion Switching Variation Transient e e Internal Static Bypass AC to DC Rectifier DC to AC Inverter Battery F EATON CORPORATION UPS and Power Quality Products Catalogue Advanced Technologies Eaton s three phase UPS products are based on the same technical platform including a similar internal topology common control hardware and algorithms standardised communications capabilities and a common user interface e UPS units behave in a uniform way and carry similar features e Product upgrades are easier as the process is identical e Improved service capabilities due t
67. hus preventing battery corrosion The exceptional ABM function prolongs the service life of batteries by up to 50 Typical applications e High capacity computers e Server rooms e Networks Process automation control equipment e Telecommunication applications e Offshore military and special projects 44 EATON CORPORATION UPS and Power Quality Products Catalogue Premier Three phase UPS for servers and industrial applications Eaton 9355 Technical Specifications me JJ Mode 9355 8 N 9355 10 N 9355 12 N 9355 15 N 9355 20 N MBS 9355 30 N MBS 9355 40 N MBS Capacity kVA kilowatts 8 7 2 10 9 12 10 8 15 13 5 20 18 30 27 40 36 Dimensions mm WxDxH 305 x 702 x 817 494 x 762 x 1684 Weight kg UPS without batteries 15 UPS with internal 1xBAT 165 UPS with internal 2xBAT N A UPS with internal 3xBAT N A UPS with internal 4xBAT Typical runtime with 1xBAT Typical runtime with 2xBAT Typical runtime with 3xBAT Typical runtime with 4xBAT Operational Nominal input voltage Vac 220 380 230 400 240 415 Vac three phase Input voltage range 175 305V 276 478V at 100 load 115 200V 276 478V at 50 load Operating frequency 50 60 Hz 45 to 65 Hz Input power factor Input current distortion 5 THD in normal network condition Nominal output voltage 380 400 415 three phase 2 static 5 dynamic at 100 load change lt 1 ms response time Output voltage regulation 15
68. i Hot Sync output In the absence of common bypass the processor makes subtle xf adjustment to the inverter frequency on the basis of output power level measurement in order to find a common frequency and load balance z among the units There exists as shown in Figure 2 a relationship Figure 1 Patented Hot Sync technology provides the highest availability for load between the power imbalance and the voltage phase difference 99 99 99 999 99 9999 Hot Sync technology allows full maintenance to be performed one by one on redundant UPS modules without an external maintenance bypass switch The critical load does not need to be disconnected from the conditioned power Scheduled or unscheduled maintenance can be perfomed with the load supported continuously by the UPS grade clean power Frequencies are continuously adjusted based on P1 and P2 Moiese out of phase Outputs are synchronised mules 1 fy N f I 1 q uPS 2 AN FY I 14 I Parallel Output Load Bus Figure 2 Well balanced load share is achieved by adjusting output frequencies thus the phase difference between parallel UPS output voltages is forced to zero 8 EATON CORPORATION UPS and Power Quality Products Catalogue ABM Technology Battery service life is a major contributor to UPS reliability Since batteries are electro chemical devices their performance gradually decreases over time Premature wear out means higher costs in t
69. ications port HID compliant USB port for automatic integration with most common operating systems USB cable supplied IEC 62040 1 IEC 60950 1 IEC 62040 2 CB Report CE mark C Tick A Tick IEC 62040 2 C Tick 86 x 140 x 335 mm 86 x 170 x 335 mm 2 9 kg 3 8 kg 3 year limited warranty on UPS 2 year limited warranty on battery and 25 000 Load Protection Guarantee Optional Warranty Uplifts Battery run times are approximate and may vary with equipment configuration battery age temperature etc EATON CORPORATION UPS and Power Quality Products Catalogue Premier series 3 UPS with Advanced Surge Reduction Eaton Ellipse ECO Technology Series 3 Standby Rating 1200 1600VA Voltage 230V Backup Time Typical 5 min Configuration Rack Tower lt O Ideal for protecting e Computers and Peripherals e Broadband Modems e P Telephony Equipment e POS Equipment 30 Eaton Ellipse ECO Technical specifications Rating VA Watts ECO CONTROL energy saving Energy efficient power protection for business computers e With an efficient electrical design and the EcoControl function which automatically disables peripherals when the master device is turned off the Eaton Ellipse ECO helps you make energy savings of up to 30 per cent compared to previous generation UPSs e As well as providing a power supply backed up by a battery to keep equipment operating during a power failure the Ellipse ECO also provides eff
70. idence with Eaton a global leader with e Along history of technology leadership to give you the best protection e The most complete line of hardware and software products to fit your needs e A world class services organisation to provide you with peace of mind We have a range of service contract offers that start from a basic preventative maintenance program and range to a comprehensive apply depending on the service program including all parts and labour these programs offer support to satisfy all your business requirements options include business or after hours support on site technical response within 2 or 4 hours supported 24 hours 7 days a week we also offer a customer service support number and remote monitoring service to satisfy your on demand needs These programs can extend to 5 years and beyond so this gives you peace of mind that your initial investment will be supported in the coming months and years Please do not hesitate to contact your local sales representative to discuss your service requirements EATON CORPORATION UPS and Power Quality Products Catalogue Protecting your investment Site inspections Consultative service that aims at securing the best possible operational environment for your UPS to ensure its fault free operation Installation Eaton s service engineers can help you set up and configure your entire UPS including its connections to your monitoring system and if desired to remo
71. ides remote monitoring via the Power Xpert Gateway Card which links Eaton and non Eaton equipment to the local area network or the Internet e Tracks and records more energy parameters and provides more standard features than alternative branch circuit monitoring systems from other vendors e Delivers real time and historical information for precision analysis troubleshooting power management billing and energy planning e Streamlines and unifies the management of diverse multi vendor power distribution systems i we ms ER gr shes www eaton com powerquality 1300 UPS UPS 63 Surge Protection Devices In nanoseconds a power surge can do major damage to sensitive That s why surge protection is so critical And why Eaton builds so much equipment and data It can come from anywhere and like a bullet you quality into our full line of surge protection products Eaton has a world only know it has been by the destruction left behind beating reputation for Power Quality and a full range of surge protection solutions covering every eventuality See 7 ta mr AR ee L Ee N Vit Faton SPHNSON ALOT OF UV OUINA WATT UT TI g a m N co o AN IN telle S Latan DO 6 Eaton DSF1 Series Power and Noise Filter with Shunt Surge Diverter 3 Phase 100 800A 80 240kA Shunt Surge Diverter 3 Phase 200kA Shunt Surge Diverter
72. ilable with legacy products ESS offers the best possible efficiency and the fastest transition times to double conversion when power disturbances occur UPS EFFICIENCIES aaa EATON UPS WITH ESS EATON UPS 90 UPS EFFICIENCY 80 70 50 60 100 UPS LOAD 70 80 20 30 40 90 Extensive configurability Eaton UPS with Energy Saver System features three configurable modes of operation e Standard double conversion mode the UPS operates as normal supplying power through the power converters e Energy Saver System the power converters are in ready state and the static bypass switch allows the UPS to supply mains power directly e High Alert mode the UPS automatically transfers from ESS to double conversion and in case of multiple reoccurring utility line disturbances it stays there for preconfigured time default 1 hour until it is safe to return to ESS UPS seamlessly executes transitions through different operating modes as needed This is only possible with transformer free topologies Availability ESS is available to all 93PM and PowerXpert 9395 UPSs Also parallel UPS systems support operation in ESS mode All earlier made installations can be upgraded with ESS capability EATON CORPORATION UPS and Power Quality Products Catalogue Energy Advantage Architecture Variable Module Management System Variable Module Management System VMMS Variable Management Module System VMMS is
73. ing capability e Intelligent Power Software Suite bundled e In built Maintenance Bypass Switch on 20 30kVA models optional on 8 15kVA models Options e System Parallel Cabinets for Hot Sync Capacity Redundancy Solutions e External Maintenance Bypass Switches e Extended Battery Cabinets e X Slot connectivity options e ViewUPS X remote monitoring panel e Preventative maintenance contracts Technology Series 9 Double Conversion On line Rating 8 30kVA Voltage 220 240 380 415 Vac 50 60 Hz Backup time Typical 5 33 min internal extendable up to several hours Configuration Cabinet Eaton 9155 are Series 9 UPS designed to protect high 0 9 p f rated critical computers and servers The centralised UPS protection is an essential part of IT infrastructure in today s IT telecom healthcare banking and industrial automation applications The 9155 features active input power factor control PFC and low 2 5 Total Harmonic Distortion current with IGBT rectifier technology The Eaton 9155 operate using the unique ABM function While traditional UPS charges batteries continuously ABM charges batteries only when necessary thus preventing battery corrosion The exceptional ABM function prolongs the service life of batteries by up to 50 Typical applications e High capacity computers e Server rooms e Networks e Process automation control equipment e Telecommunication applications e Offshore mi
74. intenance without load interruption e Automatic battery test test period can be set e Internal bypass built in to supply the load even if the UPS fails e Large input voltage and frequency ranges to avoid using the batteries unnecessarily 40 EATON CORPORATION UPS and Power Quality Products Catalogue Premier series 9 scalable UPS Eaton MX Technical Specifications MX Frame 15000 MX Frame 20000 Rating kVA kW 15 KVA 13 5 kW 20 KVA 18 kW Paralleling Maximum rating redundancy 15 KVA 10 KVA 5 KVA redundancy 20 KVA 15 KVA 5 KVA redundancy 5 KVA 2x5 KVA redundancy 10 KVA 2x 5 KVA redundancy Technology VFI SS 113 on line double conversion with power factor correction convection cooled static bypass switch ome S Output voltage and frequency THDU efficiency 200 208 230 240 250 V 50 60 Hz autoselect frequency converter as standard lt 2 97 Backup time 6 Eaton MX EXB MX 2 EXB MX 3 EXB 35 min 3 EXB 60 min 6 EXB 35 min 4 EXB 60 min 8 EXB 90 min 9 EXB 7 90 min 12 EXB Slots 1 Mini Slot MX or 2 Mini Slot MX Frame for Network Card MS Relay Card MS or Network amp Modbus Card MS connectivity cards Ports Remote Power off RJ11 5 output contacts DB9 setup via Solution Pac 8 USB and DB9 serial ports EXB detection RJ45 paralleling DB 15 Operating conditions standards and approvals Performance safety EMC surge protection IEC EN 62 040 3 IEC EN 62 040 1 1 IEC EN
75. ion clutter interference and frequency fluctuations With E series DX each phase is independently double converted and regulated In addition a PFC power factor control controller is used for real time control and data processing ensuring high availability at all times Further reliability is accomplished by introducing an intelligent charge mode which significantly prolongs service life of batteries Also the possibility to have dual feed on UPS input adds availability and increases reliability of the system As an added benefit IP21 compliant design makes E Series DX a perfect fit for industrial and other applications with harsh environmental conditions An optional filter is also available for further protection against the smallest damaging particles 42 EATON CORPORATION UPS and Power Quality Products Catalogue Essential 3 Phase protection for IT and Industrial applications Description kVA Model description Part number Net weight kg Dimensions WxDxH mm Eaton E Series DX 20 KVAB EDX20K4EB EDX20K4AUB 420 x 710 x 1245 Standard models with space for internal Eaton E Series DX 30 KVA B EDX30K4EB EDX30K4AUB 195 470 x 710 x 1753 de 40 Eaton ESeries DX 40 KVAB EDXAOK4EB EDX40K4AUB 195 470x710x1758 Eaton E Series DX 20 kVA BI EDX20K4EBI EDX20K4AUBI 420 x 710 x 1245 Standard models with internal batteries Eaton E Series DX 30 KVA BI EDX30K4EBI EDX3OK4AUBI 515 470x710x1758 stale 40 Eaton E Series DX 40KVA
76. itoring capability to Network Management Cards and Power Xpert Cards It is especially well suited for monitoring rack temperature and door status Operating system shutdown can be triggered if user defined thresholds are exceeded or contact closure status changes Power Xpert Gateway Card Power Xpert Gateway cards provide Web enabled real time monitoring of Eaton UPSs and PDUs through standard onboard Web pages Power Xpert Software or third party software As an integral part of the Power Xpert Architecture the cards provide a central point to connect UPS and PDUs to an Ethernet network via an X Slot communication bay ViewUPS X ViewUPS X remote display is an LCD panel that lets users view the status of the UPS from as far as 100 m ViewUPS X has also four status LEDs and an alarm sound The display is bundled with a dedicated X Slot card that also powers the display through the communication cable In addition to the remote display connection the card has also a SELV isolated relay port for connection to monitoring systems and AS 400 computers www eaton com powerquality 1300 UPS UPS 59 Eatons Power Xpert Architecture 60 Manage Power as a Strategic Asset Today the IT infrastructure is viewed and managed as a strategic business asset Clearly the quality of the electrical power that flows through facilities data centres and server rooms should be a factor when IT managers measure infrastructure performance
77. kup time Typical 5 min Configuration Cabinet The Eaton 5SC is designed to protect workstations small servers hubs routers PCs and other electronic equipment from power disturbances Ideally suited for small to medium sized businesses the 5SC UPS features both USB and serial ports to facilitate software communication To prolong battery service life the 5SC incorporates ABM Technology which increases battery service life optimises recharge time for quick recovery after power outages and provides advanced warning of the end of useful battery life In addition incoming voltage fluctuations are corrected so they do not affect the performance of connected equipment Unlike other competitive UPSs in its class which use a simulated sine wave the Eaton 5SC provides pure sine wave output during battery operation As a result the connected load continues to receive a quality electrical waveform and operates smoothly even during power outages To preserve data integrity the 5SC is bundled with Intelligent Power Protector which contains exclusive power management software featuring extensive power monitoring and control capabilities Backed by superior performance the 5SC UPS keeps your equipment up and running without interruption Typical applications e Small office servers e High capacity PCs and workstations Product highlights e Extends battery service life and provides advanced warning of the end of useful batter
78. kup to keep equipment operating during power cuts but also provides effective protection against damaging surges The 5S protects networked equipment from back door power surges coming through Ethernet internet or telephone lines The 5S s periodic automatic battery testing ensures early detection if a battery needs to be replaced The easy to replace battery helps to extend the UPS service life The 5S can be installed vertically over or under a desk or horizontally under a screen Its compact slimline form factor even allows it to be easily integrated into environments with space constraints The 5S features an HID compliant USB port for automatic integration with common operating systems Windows Mac OS Linux The 5S is also compatible with Eaton UPS Companion power management software All models come bundled with a USB cable for PC connection Reduce wasted energy consumption from standby power drain of ECO conTAOL connected peripheral equipment with ECO Control function 850 1600VA Technology Series 5 models Line Interactive Rating 550 1600VA Voltage 240 Vac Backup time Typical 4 min Configuration Tower Ideal for protecting e Workstations e Business Telephony e Network devices e Point of sale equipment Eaton 5S Technical Specifications Rating VA W 550VA 330W 700VA 420W 850VA 510W 1200VA 750W 1600VA 1000W Electrical Charecteristics Technology Technology Line Interactive AVR
79. l ePDUs including basic ePDUs are made of rugged aluminium or steel chassis and incorporate fully shrouded circuit breakers and switches they are designed to be highly reliable and designed to last Advanced Monitored ePDU Advanced Monitored ePDUs give the data centre manager the detailed information and understanding they need to efficiently and effectively run their data centre e Monitoring Highly accurate individual outlet monitoring branch circuit monitoring and the ePDU as a whole for V W A and kWhrs Also monitor temperature and humidity in the rack via optional sensors e Control Monitor and measure key properties and alerts remotely over Ethernet or via Advanced LCD screen on the unit Communication protocols include HTTP HTTPS DHCP SNMP v1 and v3 SNTP SMTP Telnet IPv4 amp IPv6 Monitored ePDU Monitored ePDUs monitor the current draw to allow for provisioning and load balancing of servers and to ensure current draw is not approaching breaker limits e Monitoring Monitor current on input and each branch circuit to ensure accurate load balancing e Control Monitor and measure remotely over Ethernet or via LED interface on the unit Transfer Switch The STS source transfer switch is a simple and effective solution to manage the redundancy provided by two independent power sources STS handles the automatic or manual transfer of your loads between two independent power sources without interrupting the suppl
80. l reliability availability and performance A new input circuit design keeps input current THD low and input power factor near unity without compromising overall efficiency Eaton s Energy Advantage Architecture 9395 features maximised energy efficiencies with Energy Advantage ESS Architecture EAA Variable Module Management System VMMS de optimises system efficiency at low load levels and Energy Saver System ESS allows dramatic increase in UPS efficiency without sacrificing load protection 52 EATON CORPORATION UPS and Power Quality Products Catalogue Premier Modular High Efficiency UPS Solutions 200 1100kVA Eaton 9395 UPS with redundant field installed module 275 kVA field upgradable UPS U can be added for redundancy p b 550 kVA Integrated system bypass Redundant 275 kVA module ISBM uninterruptible power system Eaton 9395 Technical Specifications pursing mensions tw 0 Wits a duo 225 fers foo ooo aso eso eoo e25 1100 zoowva rosorroerooomm sioka AOOKVA and 200KVA redundant 1890x880x1880mm 1390kg Up to 95 550 600kVA and 275 300kVA redundant 1890x880x1880 mm 1430 kg Parallel capability Upto 5 modules o to 5 modules Addani EE eee redundan x880x mm Audible noise 75 to 81 5dBA 1m model dependant il Altitude max 1000 m at 40 C 275 kVA field upgrade UPS U 740x880x1880 mm 600 kg 825 kVA 3710x880x1880 mm 3460 kg 1100 kVA 4450x880x1880 mm 3460 kg TT User benefit
81. latest generation of power distribution panelboards power distribution units and remote power panels Now a new Eaton Energy Management System Upgrade Kit is available to extend these branch circuit monitoring capabilities to existing equipment from Eaton or others With the EMS Upgrade Kit you bring the entire power distribution system under the support of the EMS Even if you have a mix of older equipment from other vendors you get the insights to effectively manage the edge of the power distribution system You will be able to track and analyse e Time stamped metering alarm event and statistical information e Peak loads along with current power and frequency minimums and maximums e Voltage and power monitored all the way down to the branch breaker level e Power quality metrics such as total harmonic distortion THD and power factor PF e Load profiling to make the best decisions for energy planning This information is shown for individual circuits each panelboard and at the equipment level equipment such as a power distribution unit PDU or remote power panel RPP to provide visibility at all levels in one system Features e Extends the branch circuit monitoring capabilities of the Eaton Energy Management System EMS to legacy and third party power distribution equipment e Monitors power conditions on individual breakers panels or at the equipment level three tiers of visibility within one unit e Prov
82. litary and special projects 38 EATON CORPORATION UPS and Power Quality Products Catalogue Premier series 9 protection for centralised mission critical loads Eaton 9155 Technical specifications 10 kVA 12 kVA 20kVA 30kVA 9155 10 S 9155 10 N 9155 12 N 9155 20 N MBS 9155 30 N MBS Capacity kVA kilowatts 8 72 10 9 12 108 15 13 5 20 18 30 27 Dimensions WxDxH mm 305x702x817 305x702x817 305x702x817 305x702x817 494x762x1684 494x762x1684 305x702x1214 305x702x1214 305x702x1214 305x702x1214 e Weight kg UPS without batteries UPS with internal 1xBAT UPS with internal 2xBAT UPS with internal 3xBAT UPS with internal 4xBAT Typical runtime UPS 1xBAT 15 min 10 min 8 min 5 min N A ween am m O aom tome fom fm N models 220 380 230 400 240 415 Vac three phase 175 305V 276 478V at 100 load 115 200V 276 478V at 50 load 5 THD in normal network condition Nominal output voltage 220 230 240VAC single phase Output voltage regulation 2 static 5 dynamic at 100 load change lt 1 ms response time Overload capacity 150 for 5 sec 125 for 1 min online 1000 for 20 msec bypass ports 1x relay contact 1 x emergency power off input 2 x environmental input Optional External battery cabinets isolation transformer external mechanical bypass switch X slot Web SNMP Modbus Jbus Relay Hot Sync cards www eaton com powerquality 1300 UPS UPS 39 Premier series 9 scalable UPS Eaton MX
83. ll 19 standard IT equipment e Depth adjustable 19 vertical mounting rails e U numbers printed on rails e Quick release and field reversible doors e Overall height on casters just under 2 metres fits through standard doorway e Two piece side panels provides easy access to interior e Available in flatpack or fully assembled cabinet e Quick assembly time approximately 30 minutes Specifications e Overall dimensions 600W or 800W x 1000D x 1950H e Useable height 42U Load rated to 1 000 kg static e Standard EIA 310D IEC 60297 2 e Material high grade cold and hot rolled steel all materials RoHS compliant e Finishing 5 stage iron phosphate pre treatment followed by tough scratch resistant powder coat paint Rack accessories Blanking panels Blanking panels provide a quick easy and cost effective solution to optimise air circulation within an enclosure while maintaining high aesthetics Eaton offers blanking panels in a variety of styles including tool less mechanically fastened clear and with cable pass through options in steel as well as plastic The width meets EIA 310 D standards and they come in various heights depending on style Most panels are bulk packed in quantities of 10 and 100 Features and benefits e Significantly reduces re circulation of hot exhaust air to the equipment inlet e Adds to the overall aesthetics of the data centre e 1U 2U 3U 4U 5U 6U 7U 8U and 20U dep
84. llocation Report Power Quality Report Branch Circuit Report Capacity Summary Report Event Summary Report Joint Bae Eili Power Guay Repost ite Commission JCAHO a Report Highlighted features meim oam re nn tt stilla unnnnnnn e Helps quality for LEED EE credits ir mme e Reporting hierarchies ad i organise device data Demi am pt kl Ta dar ra EP nl Cle Pu in VP ss Fm ad i ra TET l Hi iis es m AE e e Microsoft Excel integration for further kis analysis rn 1 e Web browser access NER sn e Connect to multiple databases Hi simultaneously pa x 1 5 E 8 00000 EE E EE Ss oF 3 ey Foreseer Services provide vendor independent power and energy infrastructure integration solutions that help companies reduce energy consumption and unplanned downtime due to the failure of critical power environmental safety or security systems Features and Benefits e Turns data into Distributed scalable architecture is tailored to meet organisational needs e Offered in three main categories Foreseer Software Services Foreseer Project Management Services and Foreseer Engineering Services e High performance trend analysis and forecasting tools assess equipment performance through cause analysis impact analysis capacity planning preventative maintenance assessments and trending e Extensive multi vendor device driv
85. lt 2 Input frequency range THDI 40 70Hz 50 60Hz autoselection frequency converter as standard THDI lt 5 Efficiency Crest factor short circuit current 3 1 90A 3 1 90A Overload capacity 102 110 120s 110 125 60s 125 150 10s gt 150 500ms Connections Input Terminal block up to 10 mm Outputs Terminal block 2 controlled groups of 4 IEC C13 10A 2 IEC C19 16A Batteries Typical backup times at 50 and 70 load 9SX 13 10 min 11 8 min 9SX 1 EBM 60 40 min 48 34 min 9SX 4 EBM 220 150 min 170 120 min Battery management Communication automatic recognition of external battery units ABM and Temperature compensated charging method user selectable automatic battery test deep discharge protection Communication ports block for remote On Off and 1 for remote power Off 1 USB port 1 RS232 serial port USB and RS232 ports cannot be used simultaneously 4 dry contacts DB9 1 mini terminal Communication slot 1 slot for Network MS card ModBus MS Relay MS or Industrial Relay cards Operating conditions standards and approva Is Operating temperature 0 to 40 C continuous Noise level lt 45dB lt 45dB Safety IEC EN 62040 1 UL 1778 CSA 22 2 EMC performance IEC EN 62040 2 FCC Class A IEC EN 62040 3 Performance Approvals CE CB report TUV UL C Tick
86. n ideal UPS for sensitive and critical equipment More real power for less cost High 0 9 output power factor enables the 9130 to provide its full power capability to modern IT equipment that may have a wide range of leading and lagging power factors With a 0 99 input power factor this UPS avoids the disturbances that some energy converters tend to cause Typical applications e Servers networking gear e Telecommunications VoIP security systems e Medical systems e Diagnostics and medical screening e Patient record archives e Manufacturing systems e Chip fabrication e Pharmaceutical production e Chemical processing EATON CORPORATION UPS and Power Quality Products Catalogue Product highlights e Offers premium performance with a 0 9 power factor and 95 efficiency e Increases battery service life and system uptime with ABMO battery charging technology e Enables prolonged runtime of essential equipment during power outages by allowing for orderly remote shutdown of non critical systems or processes e Ensures data and system integrity with Intelligent Power management software Options e Extended Battery Modules for extended run time and Extended Battery Cabinets for even longer run time e External Battery Charger Unit for fast charging of long run time Extended Battery Cabinets e Hard wiring kits for fixed installations e Interlocked Maintenance Bypass Switches e Mini Slot connectivity cards e Extended
87. nagement ABM amp Temperature compensated charging method user selectable Automatic battery test deep discharge protection automatic recognition of external battery units Interfaces Communication ports 1 USB port 1 RS232 serial port and relay contacts USB and RS232 ports cannot be used simultaneously 1 mini terminal block for remote ON OFF and Remote Power Off Communications card slots 1 Mini Slot for Network Card MS Relay Card MS and Network amp Modbus Card MS connectivity cards Operating conditions standards and approva Is Operating temperature 0 to 40 C Noise Level lt 45 dBA lt 45 dBA lt 45 dBA lt 50 dBA Performance Safety EMC IEC EN 62040 1 1 Safety IEC EN 62040 2 EMC IEC EN 62040 3 Performance C Tick Approvals CE CB report TUV Dimensions W x D x H Weight UPS Dimensions mm 441 x 522 x 86 2 2U mm 441 x 522 x 86 2 2U mm 441 x 522 x 86 2 2U mm 441 x 647 x 86 2 RT2U mm 441 x 497 x 130 7 RT3U mm UPS Weight kg 27 6 kg 28 5 kg 28 5 kg 38 08 RT2U 37 33 RT3U Dimensions of EBM same as UPS Weight of the EBM 32 8 kg 32 8 kg 32 8 kg 46 4kg RT2U 44 4kg RT3U Customer Service amp Support Warranty 3 years on electronics 2 years on batteries Runtimes are shown at 0 7 power factor Backup times are approximate and may vary with equipment configuration battery age temperature etc
88. ncluding SNMP Web card or relay contact card Eaton s Intelligent Power Software Suite compatible Rack Tower versatile with all major OS including virtualisation software such as VMware and Hyper V is included with each UPS Performance and Efficiency e With an optimised electrical design the 5PX can provide up to 99 efficiency reducing cooling and utility costs e With a power factor of 0 9 the 5PX delivers more real output power It powers more servers than other UPSs with equivalent VA ratings and lower power factors The 5PX is compatible with all modern IT equipment Intuitive LCD display for ease e When operating in battery mode the 5PX provides a high quality output of configuration and management waveform for any sensitive equipment connected such as active PFC power factor corrected servers 24 EATON CORPORATION UPS and Power Quality Products Catalogue Premier efficient amp manageable protection for high end IT applications Eaton 5PX 3000i RT2U 1 Graphical LCD display Clear information on UPS status and measurements Enhanced configuration capabilities Available in 7 languages 2 Panel for batteries replacement Hot swappable 3 1 USB port 1 serial port remote ON OFF and remote power OFF inputs 4 External battery EBM connector 5 g IEC 10A 1 IEC 16A sockets with energy metering including 4 programmable sockets 6 Mini Slot for connectivity cards Eaton 5PX Technical Sp
89. nd Industrial applications s Typical applications Eaton E Series DX e Computers and Peripherals e POS Equipment e PLC Systems e Security Systems Features e On line double conversion topology assures maximum reliability e High Frequency technology allows a compact design that delivers perfect sine wave output e Intuitive front panel LCD user interface for consistent status indication e 0 8 Power Factor output e Internal battery option for short run times e Tested for generator compatibility e Automatic bypass for fault tolerance e Built in maintenance bypass switch e Parallelable for N X capacity amp redundancy e WINPOWER software monitors power conditions Options e SNMP Web Card e Modbus Card e External Maintenance Bypass Switch e Extended Battery Cabinets Technology Series 9 Double Conversion On Line Rating 20kVA 40kVA Voltage 380 415 Vac 50 60Hz Backup Time Typical 5 14 min internal extendable up to several hours Configuration Tower The Eaton E Series DX is a three phase double conversion uninterruptible power supply UPS and is available in 20 30 and 40kVA output power ratings Its design fits perfectly to any environment where uninterrupted power feed is required to secure critical equipment s continuous operation The E Series DX UPS provides a perfect solution for power protection and solves power quality problems such as surges spikes voltage fluctuations harmonic distort
90. ng 2 5 THD i harmonics e High 0 9 pf output rating for server and high computer loads e Market leading internal battery runtime e User friendly graphical LCD display with light blue back light e Web SNMP and ModBus monitoring capability e Intelligent Power Software Suite bundled e In built Maintenance Bypass Switch on 20 40kVA models optional on 8 15kVA models Options e System Parallel Cabinets for Hot Sync Capacity Redundancy Solutions e UPS Centre distribution cabinets for small computer room applications e External Maintenance Bypass Switches e Extended Battery Cabinets e X Slot connectivity options e ViewUPS X remote monitoring panel e Preventative maintenance contracts Technology Series 9 Double Conversion On Line Rating 8 40 kVA Voltage 380 415 Vac 50 60 Hz Backup time Typical 5 33 min internal extendable up to several hours Configuration Cabinet Eaton 9355 are Series 9 UPS designed to protect high 0 9 p f rated critical computers and servers The centralised UPS protection is an essential part of IT infrastructure in today s IT telecom healthcare banking and industrial automation applications The 9355 features active input power factor control PFC and low 2 5 Total Harmonic Distortion current with IGBT rectifier technology The 9355 operate using the unique ABM function While traditional UPS charges batteries continuously ABM charges batteries only when necessary t
91. ng method Eaton s service engineers keep your batteries as good as new changing them when necessary and disposing of the old batteries in an environmentally sound fashion When the batteries are changed all cabling is also be replaced to prevent problems through oxidisation Finally the battery system is tested under normal operating conditions System upgrades During maintenance visits our service engineers analyse the load and performance of your UPS and if necessary suggest changes to accommodate new needs You will never find yourself running an obsolete or undersized system Spare parts Entering an Eaton service agreement guarantees you the use of only the best quality factory approved spare parts Authorised Eaton s service representatives stock the most often needed spares and their stocks are quickly replenished from Eaton s strategically located regional logistics centres The cost of spares is included in all Powertrust Service Plan options On line Remote Service Your UPSs can link directly to Eaton s regional Service Centre via the Web Remote monitoring software residing on Eaton s computers will keep an eye on your UPS status sounding an alarm immediately if its monitored parameters are out of the ordinary The remote monitoring system can only link into your UPS It has absolutely no access to your business data Alarms received are relayed by mobile phone to Eaton s duty engineer who takes action immediately The remo
92. ns Rating OVA 100kVA 120kVA 160KVA 200KVA 300KVA A00KVA 93E80U MBS 93E100N MBS 93E120N MBS 93E160U 1B 93E200N IB 93E300U IB 93E400N IB Capacity kVA kilowatts 80 72 100 90 120 108 160 144 200 180 300 270 400 360 Dimensions WxDxH mm 600 x 800 x 1880 1600 x 820 x 1880 Input connection Dual Input Hardwired 190 330V 276 478V at 100 load 161 201V 276 478V at 50 load mwe farm Input current distortion lt 5 THDi at rated input load 102 125 for 10 min Overload capacity 126 150 for 1 min gt 151 for 150 msec 1000 for one cycle bypass Efficiency up to 94 98 5 in HE High Efficiency Mode LCD display Graphical LCD with blue backlight Standard communication ports 2 x Mini Slot MS 1x Emergency Power Off input 3x Building Alarm inputs 1x RS232 In built Hotsync Options External battery cabinets and racks system parallel cabinets external maintenance bypass top cable entry sidecar for 80 200kVA Mini Slot SNMP Web HUB ModBus Relay card 1000m above sea level Maximum 2000m with 1 de rating per each additional 100m above 1000m Audible noise at 1 metre lt 65dB 75 Load for 80 120 kVA lt 70dB 75 Load for 160 200 kVA lt 73dB 75 Load 300 400 kVA In the interests of continuous product improvement all specifications are subject to change without notice www eaton com powerquality 1300 UPS UPS 49 Premier modular protection for high availability systems 50 Ea
93. nt and Vantage S2 enclosure systems and can also be field retrofitted to most manufacturers enclosures The HCS contains and directs the heat exhaust of your IT equipment through the chimney that is attached to the top rear of the enclosure The hot air is then ducted to your existing CRAC units through a plenum ceiling or high air returns Active Airflow Manager Eaton s HCS pressure based system with active airflow when combined with best practices improves performance metrics considerably Allocating the correct amount of airflow at known intake locations is the key to reducing energy consumption while increasing equipment performance Best practices such as blanking panels proper perforated tile placement and the reduction of bypass airflow must be employed to ensure desired results Features and benefits e SNMP managed device with user friendly Web interface e Controller continuously monitors pressure differentials to ensure that air entering the enclosure and server is properly removed e Local LEDs indicate fan status including fan fail and over temperature e Manage up to 64 peer active Airflow Managers via Ethernet e Two integrated temperature sensors with e mail alert capabilities e Redundant power input C13 plug type is required for each input 90 240 Vac supplied by enclosure PDU s e Controller is ROHS compliant e Utilisation as your capacity demands grow e Dramatically increasing the reliability of the data centre
94. nter is the backbone of your business This is why we offer innovative mission critical solutions that obtain higher availability systems improve efficiency and offer flexible scalable solutions that meet the specific needs of your business Switch wih to Eaton 1300 UPS UPS 1300 877 www eaton Soa aie quality aupqsales eaton com Eaton also provides solutions to protect your equipment from hazards and outages that can cause million dollar losses Follow us on social media to discuss the latest product updates and support information tlin E Eaton is dedicated to ensuring that reliable efficient and safe power is available when it s needed most With unparalleled knowledge of electrical power management across industries experts at Eaton deliver customised integrated solutions to solve our customers most critical challenges Our focus is on delivering the right solution for the application But decision makers demand more than just innovative products They turn to Eaton for an unwavering commitment to personal support that makes customer success a top priority For more information visit www eaton com electrical Eaton ANZ support footprint CAIRNS TOWNSVILLE QLD GLADSTONE BRISBANE ACT SA NSW CANBERRA NEWCASTLE ADELAIDE A gt SYDNEY vic AUCKLAND MELBOURNE SALES N MANUFACTURING t SERVICE TAS LAUNCESTON WELLINGTON meen CHRISTCHURCH 2
95. ntrol hot swappable battery modules long battery runtime options multiple communication options high output power factor and high power density all in a sleek modern package Features e Protects connected equipment from five of the most common power anomalies failures surges sags under voltage and over voltage e Provides more real wattage in less space with a 0 9 power factor to protect more equipment and leave more room to expand IT systems e Offers the choice of rack mount or tower installation with space saving 2U or 3U reduced depth packages including internal batteries e Enables prioritised shutdown of non essential equipment during outages to maximise battery runtime for critical devices with PowerShare e Maximises availability with extended battery runtime options hot swappable batteries optional maintenance bypass remote monitoring and power management software 22 EATON CORPORATION UPS and Power Quality Products Catalogue Superior series 5 protection for low density IT tower and rack applications Eaton 5130 Technical Specifications Rating 1250VA 1750VA 2500VA 3000VA 3000VA XL2UAU XL2UAU XL3UAU Qutput connection 8 IEC C13 10A 8 IEC C13 10A 1 IEC C19 16A 1 IEC C19 16A 1 IEC C19 16A 8 IEC C13 10A 8 IEC C13 10A 8 IEC C13 10A Operational Nominal input voltage Vac 230 Vac 200 208 220 240 Selectable Input voltage range 160 294 Vac Operating frequency 50 60 Hz auto sensin
96. o usage of common spare parts and accessories across product families and standard service tools e Similarity of service training and documentation guarantee that customers in all countries receive the same high level of service Lower total cost of ownership The transformer free technology used in Eaton UPSs with small and lightweight filter inductors high performance IGBTs in both inverter and rectifier and advanced control algorithms brings improved performance and value Compared to legacy UPS topology designs a transformer free UPS is typically only 50 the weight and occupies just 60 the footprint Low input THD lt 5 at full load and high input power factor gt 0 99 are supported down to nearly 10 load without the need for an additional input filter In addition full load efficiency can reach up to 97 e High efficiency Less weight e Smaller footprint www eaton com powerquality 1300 UPS UPS 7 Hot Sync Technology The number one function of a UPS is to supply continuous conditioned reliable electricity to critical loads In the case of a single unit reliability can be increased by modular design where redundant internal modules can take over each others tasks if one of the modules fails To further increase reliability a true parallel configuration can be employed where two or more units share the load A failed unit is isolated while the remaining ones continue to support the critical load Com
97. on Maximise your available power e Utilise all your available power through Intelligent Power monitoring Ensure you have the power you need where you need it e Combinations of IEC C13 C19 and local sockets e Manage your moves and changes in the data centre and redistribute your power Know what power is available for you to add servers or capacity or if you are reaching capacity Maximum availability e Designed for the data centre environment and to fit in any industry standard rack e Rugged Aluminium chassis with multiple mounting options e Available in OU Vertical and 1U or 2U horizontal options e High quality components and state of the art technology and circuitry Managed ePDU Managed ePDUs offer the data centre managers the maximum functionality fully Intelligent Power distribution for complete understanding and control of Data Centre power distribution including e Monitoring highly accurate individual outlet branch circuit and full ePDU monitoring for V W A and kWhrs Also monitor temperature and humidity in the rack via optional sensors e Switching individual outlet sequencing of outlets with delays or cycling enables remote reboot of equipment e Control Monitor and control remotely over Ethernet and via Advanced LCD screen on the unit Communication protocols include HTTP HTTPS DHCP SNMP v1 and v3 SNTP SMTP Telnet IPv4 amp IPv6 Manage your power consumption e Control your
98. onal card Modbus Network or Relay 9SX also provides Remote Power off function Eaton s Intelligent Power Software Suite is included with each UPS Product highlights e Provides clean continuous power to protect critical equipment and applications from power related downtime data loss corruption and process interruption e Saves valuable rack space by delivering up to 6000VA 5400W in only 3U e Provides deployment versatility by offering rack and tower installation options with rail kits and pedestal provided Increases availability with hot swappable batteries and power module and an optional external maintenance bypass e Offers extended battery runtime options to power essential systems for more than an hour during an outage e Simplifies UPS monitoring and management with a bright LCD user interface and Intelligent Power Software Suite Options e Mini Slot connectivity cards e Extended battery modules 3U high e Extended warranty plans Premier series 9 protection for medium density rack environments Technical Specifications Rating KVA kW 5kVA 5kVA 4 5kW 6kVA 6kVA 5 4kW Electrical Characteristics Technology On line double conversion with Power Factor Correction PFC system Nominal voltage 200 208 220 230 240V Input voltage range 176 276V without derating up to 100 276V with derating Qutput voltage THDU 200 208 220 230 240V 1 THDU
99. or upgrades to input output option cards 10 250 260 Features Comprehensive metering e High end accuracy e Large easy to read display Local or remote configuration e Industry standard communication protocols Modbus e Mix and match input output options e Field upgradeable 10 100 series Metering products Providing the first line of defense against costly power problems Eaton s IQ 100 electronic power meters can perform the work of an entire wall of legacy metering equipment utilising today s technology Eaton s IQ 100 meters use 24 bit AD converters that sample at more than 400 samples per cycle and meet ANSI C12 20 standards for accuracy of 0 5 percent With such high performance measurement capability these meters can be confidently used for primary revenue metering and submetering applications Applications e Utility and commercial metering e Substations industrial facilities power generation sites and campuses e Submetering e Load studies and voltage recording e Analog meter replacement www eaton com powerquality 1300 UPS UPS 61 62 Power Management gt V GR O maLa aam ua OWer At ert somware Power Xpert Software enables you to manage the complexities of large system deployments from one desktop on one screen Web enabled hardware devices are fine in limited numbers but as the number of components grows or becomes more complex Power Xpert Software is the lo
100. petitive UPS products on the market utilise centralised or distributed load sharing technology with a Master Slave principle which introduces a risk of single point failure The absolute reliability of a UPS system can be reached with patented Eaton Hot Sync parallel load sharing technology Figure 1 e Available for both single and three phase products to meet any mission critical need up to 3 5 MVA 400V systems e Easy and modular parallel UPS system upgrade with additional Capacity or redundancy e Eliminates single point of failure Hot Sync technology is designed for parallel redundant N 1 systems to satisfy 24 7 applications It can also be used in parallel capacity systems ek Hot Sync to benefit from scalability for customers ever increasing load demands Hot Sync eliminates single point of failure with the ability to 20 EA synchronise and support critical loads independently of other UPS Utility modules in the system UPS modules can share loads without any communication wiring to the outside world No common logic i The secret here is a patented built in digital signal processor DSP Failure probability year algorithm running continuously in each unit It drives the UPS outputs SUS tes toward synchronisation and takes care of load sharing If there is a O M Modular UPS PE 10 hi Parallel redundant UPS common bypass available it is used as valid synchronisation source for F
101. power demands fe An Eaton Green Solution 46 EATON CORPORATION UPS and Power Quality Products Catalogue Premier Rack Mount 3 Phase UPS for Data Centre amp IT Applications BladeUPS Scalability Meet current and changing requirements with modular architecture The building block of the Eaton BladeUPS system is a 6U rack mount module that provides 12 kW of backup power protection The system expands easily to provide maximum results As your data centre grows the system s modularity plays a key role in optimising your capital planning and deployment Using the patented and field proven Hot Sync paralleling technology up to six BladeUPS modules can be paralleled for extra capacity or redundancy providing 60 kW of redundant backup power protection in one 19 inch rack Patented load sharing control intelligently distributes the workload among modules without requiring direct synchronisation links among them Any module can provide backup support for any other with no interruption or downtime For instance in a redundant system you could perform full maintenance on any module without any interruption of conditioned power to the protected IT equipment YEAR 1 YEAR 3 YEAR 5 INITIAL INSTALL EXPANSION FURTHER EXPANSION BladeUPS Redundant N 1 configuration Parallel Bar for Six 12 KW UPS modules share B paralleling UPS the load equally If a UPS modules module is removed from ude service the remaining mod
102. r 1 rein je Saree El pm m extended power outage G og mi man m e anora OS D m Sty Ti ad ream mm is indre ie fe Sree LA 3 fa mi lat frre mar Gi is bh tae PE oe oma eed poo we EEE a 6 et TT TE Gt ra Tee Tee Se bre ae sil d at F T v mm ene an Fingern 18 ud 5 0c00000000a000 La IE Bee Gee A fl Intelligent Power Manager supervisory software lets you monitor and manage multiple power and environmental devices across the network from a single interface giving you up to the minute information on the status of power in your network It also works seamlessly with VMware s vCenter Server and vMotion as well as Microsoft s SCVMM and Live Migration e Monitor and manage multiple power and environmental devices from any Internet browser or your vCenter dashboard e Auto discovery provides fast installation by automatically detecting devices on the network e Mass upgrading of firmware capability reduces network management card setup and maintenance time e Shutdown agent management enables safe shut down of servers e Multiple password protected access levels and support for secure communications e All the functionality of an enterprise class monitoring solution for free or at a fraction of the cost e Support for up to 10 devices included at no charge additional capacity may be purchased ren eee ec pe es ee Use each software independently or as a powerful combination Together with
103. r easy replacement of the UPS without powering down critical systems e The Eaton 9PX can be paralleled to achieve twice the power of unitary product using Eaton s proprietary Hot Sync technology Stronger longer battery life Eaton ABM battery management technology uses an innovative three stage charging technique that extends battery life by up to 50 e More run time can be added with up to 12 external hot swappable battery modules able to run systems for hours if necessary The additional battery modules are automatically Technology Series 9 Double Conversion On line recognised by the UPS Rating 6 11 kVA Voltage 1ph 1ph in out 230 Vac 200 250 Vac 3ph 1ph in out 380 415 220 240 Vac Backup time 5 240 minutes Configuration Rack mount Tower Convertible Performance and Efficiency Double conversion topology The Eaton 9PX constantly monitors power conditions and regulates voltage and frequency e With up to 95 efficiency in online double conversion mode and 98 in high efficiency mode the 9PX provides the highest efficiency level in its class to reduce energy amp cooling costs e With a 0 9 power factor the 9PX delivers 28 more power than other UPS in it s class It powers more servers than other UPSs with equivalent VA ratings and lower power factors e With a RT Rack tower versatile form factor the 9PX is the most compact solution in its class delivering up to 5 4kW in only 3U and 10kW in only 6U Managea
104. rshare sockets Additional outputs with HotSwap MBP Additional outputs with FlexPDU Battery Typical backup times for 50 and 70 load 6 except for Eaton EX 3000 XL 5 18 min 12 min 13 min 9 min 17 min 12 min 15 min 10 min EX 1 EXB 75 min 50 min 50 min 35 min 85 min 60 min 60 min 40 min EX 4 EXB 250 min 200 min 180 min 120 min 285 min 200 min 190 min 150 min Battery management Automatic weekly test period adjustable using LCD display or in software supplied automatic recognition of external battery units gt continuous maximisation of backup time deep discharge protection m Indicators and display 3 x LEDS adjustable multilingual display display of measurements access to control and set up menus Warranty Optional 3 years warranty depending on the country please visit www eaton com powerquality 1 Maximum rating with EXB battery units Eaton EX 1000 800 W Eaton EX 1500 1200 W and Eaton EX 3000 2400W 2 Lower limits for lt 20 lt 33 lt 66 gt 66 of nominal power VA For active output power greater than 0 7 and 0 8 nominal rating the lower limit is 180V and 190V respectively 3 Derated by 15 when used as a frequency converter 4 USB and RS232 serial ports cannot be used simultaneously 5 Except Eaton EX 3000 XL UPS with high speed charger without built in batteries for custom configurations ask us for details 6 Runtimes are shown at 0 7 power factor Backup times are appro
105. s S included User benefits B Control panel LCD 8 lines x 40 characters Input characteristics Optional Voltage Remote display panel Optional Voltage range 15 20 F Buildings alarm inputs 2 galvanic isolated Frequency range Serviceability Input current distortion 3 5 in nominal load condition Back side against wall installation Standard Sanaa 6 Internal backfeed Yes except on 200 400kVA models Integrated maintenance bypass Protection Input breaker Output characteristics in line and match cabinets Voltage MC Communications 0 7 lagging to 0 8 leading Internal N 1 redundance capable Field upgradeable N System bypass module Power factor Regulation Inverter Voltage THD Load power factor range Battery Software compatibility Power Xpert Communication cards Two communication bays standard Maximum of four communication bays with the communication expansion option The following connectivity options can be installed at any time VRLA AGM 480 V Battery types Battery voltage Temperature compensation ConnectUPS Web SNMP xHub Modus card Relay imertace Card Use for Optional AS400s Industrial Relay Card 5A 120V Hot Sync CAN Bridge Card provides CAN communications isolated RS 485 port Environmental Monitoring Probe EMP Charging method Advanced battery management technology www eaton com powerquality 1300 UPS UPS 53 54 Intelligent Power Distributi
106. s the first product on the market to offer a Online Double Conversion On Demand power technology This innovative design takes into consideration the design capabilities of the actual computer power supplies in such a manner that the UPS furthers that capability in order to provide an extremely efficient and robust protection solution without generating additional heat The BladeUPS is a rack mounted three phase input and three phase output uninterruptible power system Each 12kW module can be paralleled to achieve a maximum 60 kW N 1 system Paralleling can be accomplished for either redundancy or capacity purposes Each 12 kW module is identical and can be converted from a single stand alone UPS to a system capable of being paralleled by simply changing the power cord The BladeUPS is designed for computer data centre installations Paralleling of the BladeUPS modules takes place in the BladeUPS bar which is mounted separately in the rear of the IT rack This bar provides the required input and output power connections for 4 or 6 BladeUPS modules Each BladeUPS bar comes equipped with fully rated input and output lugs within a designated wiring area The protected load can be connected to the wiring section or distributed output can be taken in 12 kW increments from the locking output connector on the rear of the BladeUPS module A single BladeUPS module can be connected to the BladeUPS bar with additional modules installed to meet future
107. s to transparently move virtual machines from a server affected by a power interruption to an available server on the network ensuring data integrity and zero downtime technology alliance E vmware PARTNER EMC Microsoft EATON CORPORATION UPS and Power Quality Products Catalogue Options to Manage and Monitor Your UPS Network Management Cards Network Card MS ConnectUPS Web SNMP card Network Card MS and ConnectUPS Web SNMP cards are a complete UPS monitoring control and shutdown solution in a networked IT environment In case of alert the Web SNMP card can notify users and administrators through e mail and SNMP traps In case of a prolonged power failure the protected computer systems can be shut down ina graceful manner with Intelligent Power software The unique three port switching hub on the X Slot model provides additional network connections Industrial Network Cards ModBus cards Network amp Modbus Card MS and X Slot Modbus cards connect the UPS to industrial and building management systems using ModBus RTU protocol Power Xpert Cards Relay Cards Relay AS400 cards Relay Card MS Minislot Industrial Relay Card and X Slot Relay cards are an easy connection to IBM AS 400 series computers as well as industrial and building management systems Other Devices Environmental Monitoring Probe Environmental Monitoring Probe EMP adds temperature humidity and two contact closure mon
108. t 52 dBA Certification Markings C Tick CE GS EMC EN62040 2 Emisions category C1 Immunity category C2 Battery Runtimes in minutes Standard Extended Battery Modules Load VA Watts Of Load Internal Batteries w 1 EBM w 2 EBM w 3 EBM w 4 EBM PW9130G1000R XL2UAU 1000 900 100 6 31 51 82 100 500 450 50 19 68 111 192 246 PW9130G1500R XL2UAU 1500 1350 100 5 24 46 69 90 150 675 50 14 61 112 172 221 PW9130G2000R XL2UAU 2000 1800 100 6 33 59 88 119 1000 900 50 17 72 129 183 260 PW9130G3000R XL2UAU 3000 2700 100 3 18 34 53 69 1500 1350 50 9 45 84 122 165 www eaton com powerquality 1300 UPS UPS 33 34 Premier series 9 protection for medium density rack environments Eaton 9SX Technology Series 9 Double Conversion On Line Rating 5 6kVA Voltage 230Vac 200 240Vac Configuration Rack mount Tower convertible Performance and Efficiency e Double conversion topology The Eaton 9SX constantly monitors power conditions and regulates voltage and frequency e With up to 94 efficiency in online double conversion mode the 9SX provides the highest efficiency level in its class to reduce energy amp cooling costs e With a 0 9 power factor the 9SX delivers 28 more power than UPS in its class It powers more servers than other UPSs with equivalent VA ratings and lower power factors Availabili
109. t connector 5 EXB units recognised automatically 6 8x IEC 10A sockets including 4 x Powershare programmable sockets and 1 x IEC 16A socket 7 Mini Slot connectivity card slot 8 Mountings for HotSwap MBP and FlexPDU 2 Panel for batteries replacement Hot swappable Eaton EX Eaton EX Technical Specifications 1000 RT2U 1500 RT2U 2200 3000 3000 XL 1000 VA 900 W1 1500 VA 1350 W 1 2200 VA 1980 W 3000 VA 2700 W 1 RT2U tower rack 2U RT2U tower rack 2U and RT3U tower rack 3U Rating VA W Format Electrical characteristics Architecture On line double conversion with automatic by pass and power factor correction Input voltage and frequency ranges without using batteries 100 120 140 160 V 2 to 284V 40 to 70 Hz 100 120 160 184 V 2 to 284V 40 to 70 Hz 230 V adjustable to 200 208 220 240 250 V 50 60 Hz auto select or frequency converter mode 3 230 V adjustable to 200 208 220 240 V 50 60 Hz auto select or frequency converter mode Output voltage and frequency 1 x IEC C14 10A socket 1 x IEC C20 16A or terminal block on HotSwap MBP HW Hard Wired 8 x IEC C13 10A sockets 1 x IEC C19 16A socket 2 groups of 2 x IEC C13 10A on Eaton EX Input 6 x IEC C13 10A sockets 2 independent groups 2 1 x IEC C13 10A sockets 4 x Aust 3 pin or 6 x IEC 10A sockets or terminal blocks HW version 6 x Aust 3 pin or 12 x IEC 10A sockets Outputs Remotely controlled Powe
110. te monitoring is an ideal enhancement to your service package Ask your Eaton representative for details Extended Service Plans ESP Extended Warranty and Service Plans for Eaton Single Phase UPS Eaton s Extended Service Plans ESP are a suite of warranty uplift and enhanced service plans tailored to suit Eaton s Single Phase UPS portfolio in most deployment applications ESP provides cost effective amp hassle free extended warranty and service enhancements for Eaton s single phase UPS products for up to 4 years from date of purchase or commissioning Just set and forget when you purchase an ESP as Eaton partners with YOU simplifying the post sales support process of your critical power infrastructure When you purchase an Eaton ESP product a range of additional support benefits are opened up to you including e Warranty extension e Advance replacement e Streamlined logistics Contract customer status amp priority service Strategically designed for the most critical of IT assets our premier level of cover Warranty Premium additionally includes start up commissioning plus an annual preventative maintenance visit for the duration of the ESP ESP is an ideal customer care solution in today s ALWAYS ON business environment Eaton ESP overview 1 Warranty Standard e Applicable for Eaton s single phase UPS systems up to 11kVA e Available for 3rd or 4th year uplift e Same business day dispatch advance replacement
111. te monitoring system Commissioning Our service engineers help you start up your UPS and make sure it works as intended performing all necessary checks before turning the system over to you Preventative maintenance Equipment cleaning inspection of installation and operation environment mechanical inspection measurements and adjustments battery condition check system check event log analysis necessary action and eventual repairs Usually performed once a year unless otherwise agreed Reports After each maintenance visit whether regular or emergency you receive a full written report on the fault and steps undertaken to repair it 24 hour telephone support 24 hour 365 days a year access to Eaton s support engineers for immediate help on your UPS system Available free of charge to all Service plan customers Extended warranty For a small fee you can extend the warranty of your UPSs incrementally up to 5 years for all single phase product range Power quality analysis As time goes by the loads on both your UPS and the mains may change Eaton s service engineers can analyse the quality of the power being fed to your equipment and suggest remedies if necessary Battery analysis and replacement Because batteries are the most important part of a UPS we pay particular attention to their condition Only rigorously tested high quality batteries are used in Eaton UPSs Battery life is optimised through our ABMO battery chargi
112. tery Overload performance 108 5 to 150 5 for 30 secs 105 130 for 10 mins 2130 for 1 sec up to 130 continuous on bypass Input Connection C14 10A C14 10A C20 16A Hard Wired Output receptacles 4 IEC C13 10A 6 IEC C13 10A 4 IEC C13 10A Hard Wired amp Hard Wired Battery Battery Quantity Type 3x 12V 7 2Ah 8x12V 7 2Ah 8x12V 7 2Ah 20x 12V 20 x 12V 9Ah N A Standard 7 2Ah Battery Quantity XL 3x 12V 8 x 12V 8 x 12V 20 x 12V Re charge time to 90 8 hours capacity lt 7 hours XL Models dependant on battery capacity Start On Battery UPS can be started without being connected to AC utility power User Interface Visual LED mimic diagram with 4 x LEDs for Utility Bypass Inverter amp Battery Status 5 LED Bar Graph for Load and Battery Capacity Fault LED Control Two buttons for On Off and Test Alarm Silence Communications management Power Management WinPower power management software included on CD Software Connection Type Standard RS232 DB9 Connectivity slot Intelligent Slot for optional SNMP card AS 400 Relay Card Modbus Card Operating Temperature 0 C 40 C Humidity 5 95 Non Condensing Noise Level 1m lt 50dBA lt 50dBA lt 50dBA lt 55dBA Standards IEC61000 4 2 Level 4 IEC61000 4 3 Level 3 IEC61000 4 4 Level 4 IEC61000 4 4 Level 4 IEC62040 1 EN55022 Class B CE Mark Dimensions amp Weights W x H x D mm Standard Models 145 x 220 x 400
113. the complete loss of power They excel at tightly regulating the voltage providing superior noise attenuation and are ruggedly designed to withstand the harshest electrical environments Possessing no moving parts ferroresonant power conditioners are virtually maintenance free What is Ferroresonance Simply put ferroresonance is the property of a transformer design in which the transformer contains two 2 separate magnetic paths with limited coupling between them The output contains a parallel resonant tank circuit and draws power from the primary to replace the power delivered to the load Note that resonance in ferroresonance is similar to that in linear circuits with series or parallel inductors and capacitors where the impedance peaks at a particular frequency In a non linear circuit such as a ferroresonant transformer resonance is used to reduce the changes in supply voltage and provide more constant voltage to the load A magnetic device is non linear Its reluctance changes abruptly above a certain magnetic flux density At this point the magnetic device is defined as being in saturation The design of the ferroresonant transformer allows one magnetic path to be in saturation while the other is not As a result further change in the primary voltage will not translate into changes in the saturated or secondary voltage and voltage regulation results 40 336V 240V Normal Voltage Input Voltage Range
114. tion with Eaton Branded worksections provide specifiers with an alternative to the generic worksection where a particular product has been selected at the design stage www eaton com powerquality 1300 UPS UPS 69 70 EATON CORPORATION UPS and Power Quality Products Catalogue Pi seu h bi wee ia A T i TOT sr I ET pk kb kb ak as dd dd J E e E oe E L 4 nj mam i j E i Ty repre sw ea FYN EE ai O ey M A a a iry ih 7 dm 4 ag iy RE F hi Le tA EEEE E TITT TT oy TD 2 1 FYYYTTTTTTET bce lah tkd gle dd dad ad disk bil i i if y aji r r r r Pe r r r J kb EEE RAGA AEG LKR ke ea k ka KAGGE Fe a a a i Ka ak be see EEE mn PENNE Meh by hehehe eta ry Ty NYTTET ka t r RLE tf i EE Patt ct MAYA 184 T E U p i LE m k hi ae i ee PS BI d Bek I TY j pg p E F p I q Vi 5 J J gu CN 4 Go G f V N y T JE N 2 Fo e I DD ALT r 7 A vr va J LICITIGV d B Powering Business Worldwide A re a e E Va FAYANC THAT ON l 1 Ss I JD ia D L CA be m ee e Cf i effici mi m A ent anqa At Eaton we know that your data ce
115. tive equipment to malfunction or fail The Sola 26 range of power conditioners provide an immediate answer to this inconvenience by suppressing and isolating power line interference and regulating the output voltage to 5 These hardwired power conditioners provide the unique feature of selectable input tap for greater versatility and output voltage taps are also provided These features make the Sola 26 power conditioner the ideal choice for a regulated power supply where a three phase source is provided without a neutral line The Sola 26 power conditioner provides superior noise rejection exceeding 120 dB common mode and 60 dB transverse mode noise rejection By nature of design this product is a true ultra isolation device The Sola 26 is available from 500VA through to 15kVA as a panel mounting hardwired unit specifications Built to protect Remote computer peripherals 500 5000VA Models Field selectable e Copiers and laser printers 110 120V or 220 240 or 380 415V e Process control equipment 1 5 15KVA Models Field selectable 220 240V or 380 415V Field Selectable 110 120 220 240 Volts AC 5 for an input line variation of Orderina details 15 5 8 for 40 input 3 Part N Heigh Output Harmonic Distortion Less than 3 THD on linear loads No d MN 9 i H mm greater than 5 on typical computer loads 85 at full load 2605 0500M 2605 1000M Dropout No loss of output for
116. ton 93PM Technology Series 9 Double Conversion On Line Rating 30 50kW at 1 0 p f Voltage 230 400VAC 50 60 Hz Backup 10 20 min internal extendable up to several hours Configuration Cabinet Introducing the Eaton 93PM UPS helping you to combat the costs of energy and the ever increasing power demands of IT infrastructure Featuring industry leading operating efficiency of 96 7 and world class intelligent software solutions the 93PM is the surest way to secure the continuity of your mission critical applications All this compactly in 0 5 m2 On line double conversion topology ensures the UPS output is not affected by any abnormalities in the utility power and keeps critical load equipment protected against all common power problems With Eaton 93PM UPS modern multi level converter technology ensures that in double conversion no energy is wasted and the UPS operating efficiency is top of market 96 7 resulting in significant savings in operational costs Energy Saver System delivers superior gt 99 efficiency Even small increases in UPS efficiency can quickly translate into thousands of dollars realised in more real power and lower cooling costs Energy Saver System enables gt 99 efficiency across the typical UPS operating range In ESS the load is powered securely through the static bypass line with double conversion available on demand with typical 2 ms transition time in the event of any abnormality on supply source
117. ton modular 9395 UPS and VMMS Full system efficiency potmized according to the load level hi ee oe E m LILLA TALK OY UPS UPM in idle mode i Extensive Configurability Customers can decide how to configure their system establishing the number of redundant UPMs and the maximum load level per UPM VMMS can be used in single multiple UPM and multi UPS Power Xpert 9395 systems e Single 9395 units from 550 kVA to 1100 kVA e Distributed parallel systems Xx275 Xx550 Xx825 Xx1100 e SBM centralised bypass system Earlier installations can also be upgraded with VMMS Applications Applications where VMMS is particularly efficient e Redundant N 1 and 2N systems Lightly loaded lt 45 load level e Critical data centres especially when UPS feeds dual corded servers e Any applications where load varies frequently Availability VMMS is available to all 9395 UPSs All earlier made installations can be upgraded with VMMS capability www eaton com powerquality 1300 UPS UPS 11 12 Protecting vour investment Only Eaton is authorised to perform service using Eaton diagnostic software to calibrate start up reset communications and perform critical service repairs Service contracts are your best value compared to the cost and risk of time and material Downtime and lost data are priceless Please do not wait until there is an emergency to realize the value of having a service contract Place your conf
118. tor cables included Characteristics Nominal Input Voltage 230V Output Voltage 230V Adjustable to 220 230 240 Frequency 50 60Hz Autoselect Input Protection Resettable Circuit Breaker Features ECO Control Yes up to 30 energy savings Line Protection Telephone Fax Modem Internet Ethernet Battery Battery Type Replaceable Sealed Lead Acid Cold Start Yes Deep Discharge Protection Yes Battery Replacement Indicators LED and Audible Runtime at 50 load 10 min 11 min Runtime at 70 load 6 min 6 min Communication Standards Safety EMC Surge Protection Dimensions H x W x D Weight Customer Service and Support Warranty Warranty Accessories Communications port HID compliant USB port for automatic integration with most common operating systems USB cable included IEC 62040 1 IEC 60950 1 IEC 62040 2 CB Report CE mark C Tick A Tick IEC 61643 1 305 x 81 x 312 6 7kg 305 x 81 x 312 7 8kg 3 year limited warranty on UPS 2 year limited warranty on battery and 25 000 Load Protection Guarantee Optional Warranty Uplifts 19 Rack Kit ELRACK Wall Mount Kit ELWALL Battery run times are approximate and may vary with equipment configuration battery age temperature etc www eaton com powerquality 1300 UPS UPS 15 Essential series 5 Power Protection The 5E line interactive uninterruptible power system UPS provides Eaton D a
119. ttery start capability Qutput wiring 30 kW lt 4 5 40 200 kW lt 3 Yes Yes VRLA ABM technology or Float Optional 432 V 36 x 12 V 216 cells or 480 V 40 x 12 V 240 cells Note Strings with different battery voltage may not be paralleled 30 50 kW 16 5 A 80 100 kW 33 A 120 150 kW 49 5 A 160 200 kW 66 A Yes 3ph N PE 220 380 230 400 240 415 V 50 60 Hz Nominal voltage rating configurable Output UTHD Rated output power factor lt 1 100 linear load lt 5 reference non linear load 1 0 Permitted load power factor Overload on inverter Overload when bypass available Accessories options 0 8 lagging 0 8 leading 10 min 102 110 60 sec 111 125 10 sec 126 150 300 ms gt 150 On battery mode 300 ms gt 126 Continuous lt 125 10 ms 1000 Note Bypass fuses may limit the overload capability External battery cabinets with long life batteries External maintenance bypass switch integrated manual bypass up to 150kW and MiniSlot connectivity Web SNMP ModBus Jbus Relay Communications MiniSlot Network SNMP interface Serial ports Relay inputs outputs Environmental Operating temperature Storage temperature Altitude Audible noise at 1 metre Compliance with standarts Safety CB certified EMC Performance 3 communication bays Yes standard Built in host and device USB 5 relay inputs and dedicated EPO 1 relay output 0 C to 40 C
120. ty and Flexibility e The internal bypass allows service continuity in case of internal fault Batteries are hot swappable from the front panel without powering down critical systems With its rack tower versatile form factor the 9SX can be installed in any environment rack kit provided as standard on RT versions Stronger longer battery life Eaton ABM battery management technology uses an innovative three stage charging technique that extends battery life by up to 50 More runtime can be added with up to 12 external hot swappable battery modules able to run systems for hours if necessary The additional battery modules are automatically recognised by the UPS EATON CORPORATION UPS and Power Quality Products Catalogue Manageability The new graphical LCD provides clear information on the UPS s status and measurements on a single screen in seven languages LCD display position can be adjusted to offer the best viewable angle for tower and rack usage The 9SX can meter energy consumption kWh values can be monitored using the LCD or Eaton s Intelligent Power Software Suite Load segment control enables prioritised shutdowns of nonessential equipment to maximise battery runtime for critical devices It can also be used to remotely reboot locked up equipment or to manage scheduled shutdowns and sequential start ups The 9SX offers Serial USB and relay 4 dry contacts connectivity plus an extra slot for an opti
121. ue Corporate overview Powering Business Worldwide Founded in 1911 Eaton is a diversified industrial manufacturer and a global leader in various industrial markets including e Electrical systems and components for power quality distribution and control e Hydraulics components systems and services for industrial and mobile equipment e Hydraulics fuel and pneumatic systems for commercial and military aircraft e Intelligent truck drivetrain systems for safety and fuel economy e Automotive engine air management systems powertrain solutions and specialty controls for performance fuel economy and safety Eaton has approximately 102 000 employees worldwide and sells products to customers in more than 175 countries www eaton com powerquality 1300 UPS UPS 3 Sustainable by Design Sustainability has always been at the heart At Eaton we apply the ISO 14001 an international environmental fE te fine hi h management system on site and R amp D certification to all of our facilities of Eaton s business t j Means meeting the In addition to clearly demonstrate and communicate the environmental current needs of our society while enabling value of the products to customers and consumers Eaton has developed a rigorous evaluation process based on the guidelines of international future generations to meet their own needs organisations such as the International Standards Organisation ISO Sustainable design for our products m
122. ules seamlessly support the load without interruption 42U Eaton Enclosure Three 12 kW UPS Total Rack modules 36 kW Space 24U of backup power L m 12 kW 6U electrical a Eaton wire way BladeUPS occupies 6U of space 12kW 36kW or 24kW N 1 60kW N 1 Battery runtimes are approximate and may vary with equipment configuration battery age temperature etc Runtimes at 0 7 pf www eaton com powerquality 1300 UPS UPS 47 48 Essential protection for Data Centre and Industrial applications Eaton 93E Technology Series 9 Double Conversion On Line Rating 80 400 kVA at 0 9 p f Voltage 230 400VAC 50 60 Hz Backup Typical 5 60 min extendable up to several hours Configuration Cabinet The Eaton 93E UPS delivers superior power protection for ever expanding loads in today s space constrained data centres Facilitating a lower total cost of ownership TCO through a combination of energy efficiency high reliability and a compact footprint the 93E is an ideal solution for small to medium sized data centres and other applications desiring highly reliable power protection Energy efficient design With a transformer free design and sophisticated sensing and control circuitry the 93E is capable of achieving up to a 98 efficiency rating making it one of the most energy efficient UPSs in its class and it still provides maximum load protection Unlike most high efficiency UPSs the 93E e Pro
123. ully or partly discharged battery the charger starts at a constant current appropriate for the battery type used When the battery voltage reaches a set level the operation is changed to float mode using a constant but lower voltage thus providing an optimum recharge time The battery is kept at this voltage for 24 hours until it comes to the first test point This takes approximately one minute and during this period voltage drop measurements are taken while loading the battery giving an indication of battery condition The float charging is continued for an additional 24 hours plus a period equal to 1 5 times the constant current charging time before the rest mode is initiated At this point the charging is discontinued for a maximum of 28 days as if the batteries were Battery ff test 48 hours 1 5xchg time Chg time max 28 days Float mode Rest mode constant voltage Charge mode constant current Battery voltage during ABMO charging process Charge Time mode e Predictive and automatic diagnostics of Battery Health e Significant extension of battery life compared to traditional charging method e Optimisation of battery recharging time with dual mode charging method Automatic battery charge voltage compensation within 0 to 50 C temperature range disconnected During the first 10 days the battery voltage is continuously monitored and if it drops below 2 1 V cell the ABM re starts in charge mode
124. urchase A confirmation email will be provided to the customer upon registration for further information and scheduling details where applicable Superior series 3 power protection for office and home computer equipment e In the event of a total blackout the unit provides sufficient battery backup time to last through most power outages e The 700VA model saves up to 30 energy through its EcoControl function which automatically disables peripherals when the master device such as a computer is turned off e The 3S also protects telephone broadband and Ethernet line from back door power surges Eaton 35 e The shutdown software makes it possible to automatically save your work and shut down your application without losing any data Once the power is restored you can continue working exactly where you left off Easy integration and installation e Attractive design and glossy finish make the 3S a perfect fit for the modern office environment e The 3S comes with a fixed input cable and 6 Australian outlets for easy connection of typical computer configurations with peripherals e The 3S features a HID compliant USB port cable supplied for automatic integration with common operating systems Windows Mac OS Linux Compact unit fits on or under your desk or can be mounted on a wall Technology Series 3 Standby m Te Rating 550 amp 7O0VA ECO conTROL Easy to replace battery helps to extend UPS service life Voltage
125. vides surge suppression for the load e Detects the location of faults utility or load and takes the appropriate action e Switches to double conversion operation in less than 4ms High system efficiency reduces utility cost extends battery run times and ensures cooler operating conditions Real compatibility Active power factor correction PFC provides 0 99 input power factor and lt 5 ITHD thus eliminating interference with other critical equipment in the same network and enhancing compatibility with generators The 93E is optimised for protecting modern 0 9 p f rated IT equipment without the need to oversize Eaton UPS and Power Quality Products Catalogue True reliability Patented Eaton Hot Sync technology makes it possible to parallel up to four UPSs to increase availability or add capacity The technology enables load sharing without any communication line thus eliminating single point of failure Compact amp serviceable design Small footprint occupies minimal floor space e Up to 35 smaller than similar competitive solutions e 600mm wide UPS cabinet 80 200kVA models enables seamless in row integration with IT racks The 93E is easily and quickly serviced to provide the highest level of availability with Mean Time to Repair MTTR lt 30 minutes With its Easy Capacity Test feature the 93E can test its entire power train under full load stress without the requirement of an external load User Interfa
126. warranty plans Premier series 9 Tower UPS for all critical applications Eaton 9130 Tower Technical Specifications 1 IEC C13 10A 1 IEC C19 16A Rating 700VA 1000VA 1500VA 2000VA 3000VA 6000VA Part number PW9130G700T XLAU PW9130G1000T XLAU PW9130G1500T XLAU PW9130G2000T XLAU PW9130G3000T XLAU PW9130G6000T XLAU Capacity VA Watts 700 630 1000 900 1500 1350 2000 1800 3000 2700 6000 5400 Dimensions WxDxH mm 160x355x250 160x383x250 160x435x250 214x410x345 214x410x345 242x542x575 Weight kg 12 2 14 5 19 0 34 5 34 5 75 5 Input connection IEC C14 10A IEC C14 10A IEC C14 10A IEC C14 10A IEC C20 16A Hard Wired Output connection 4 AUST 10A 4 AUST 10A 4 AUST 10A 5 AUST 10A 5 AUST 15A Hard Wired Operational Nominal input voltage Vac 240Vac 200 208 220 230 selectable Input voltage range 700 1500VA 120 140 160 276 Vac at 33 66 100 0 7pf load 2000 3000VA 140 160 180 276 Vac at 33 66 100 0 7pf load 6000VA 120 140 160 180 276V 25 50 75 100 0 9pf Load Operating frequency 50 60 Hz auto sensing tolerance 40 70Hz Input power factor 0 99 Nominal output voltage 240Vac 200 208 220 230 selectable Qutput voltage regulation 2 Overload capacity 700 3000VA Up to 130 for 12 seconds 130 150 for 2 sec 6000VA Up to 130 for 120 seconds 130 150 for 30 sec Efficiency 700 2000VA 90 online 93 High Efficiency Mode 3000VA
127. ximate and may vary with equipment configuration battery age temperature etc 7 compatible with 600 mm deep rack Part Numbers EX RT3U excludes rack kit M68400 M68402 XL M68404 EX RT2U includes rack kit M68182 M68184 M68401 M68403 EX EXB M68186 includes rack kit M68186 includes rack kit M68405 M68405 EX Rack Kit 2U 3U M68441 M68441 www eaton com powerquality 1300 UPS UPS 29 30 Premier series 9 Tower UPS for all critical applications Eaton 9130 lower Technology Series 9 Double Conversion On Line Rating 700 6000VA Voltage 208 240Vac Configuration Tower The Eaton 9130 UPS resolves utility power problems and delivers superior power protection for IT and networking equipment medical systems manufacturing process control or anywhere critical equipment and applications require clean continuous power Double conversion design for superior power protection The 9130 is constantly monitoring power conditions regulating both voltage and frequency Even when presented with the most severe power problems this UPS s output remains within two percent of nominal voltage With a wide input voltage range the 9130 does not depend on batteries to smooth out minor power fluctuations Batteries are conserved for those times when utility power is highly unstable or completely out If an outage occurs the 9130 transfers to battery with zero interruption in power making this a
128. y life with ABM Technology e Delivers smooth continuous power with pure sine wave output Regulates power fluctuations with Buck and Boost voltage regulation e Hot swappable batteries e LCD provides at a glance indication of status and important parameters e Minimises downtime with hot swappable batteries e Communicates with Intelligent Power Protector software via serial and USB ports e Provides investment protection with a two year limited warranty Options e Extended warranty plans EATON CORPORATION UPS and Power Quality Products Catalogue Superior series 5 performance Eaton 5SC Technical Specifications Capacity VA Watts 500 350 750 525 1000 700 1500 1050 4 IEC C13 10A 6 IEC C13 10A 8 IEC C13 10A 8 IEC C13 10A Ol fom fem fam Qutput voltage regulation 230V 6 10 Adjustable to 220V 230V 240V 50 60 Hz 0 1 autosensing Overload capacity 120 5 min 150 10 sec Battery Runtimes in minutes me mm mw Je Ja fr 8 EK owen G o o o a a T a a a T a map Er a E E Cum pp pp Battery run times are approximate and may vary with equipment configuration battery age temperature etc www eaton com powerquality 1300 UPS UPS 20 Premier high density series 5 protection for network devices Eaton 5P Technology Series 5 Line Interactive Rating 650 1550VA Voltage 230 Vac Backup time 5 10 minutes Configuration Rack and Tower mount Manageability The graphic
129. y of power lt 6 milliseconds Either of the two sources may be designated as the preferred source with the other becoming the alternate source In the event of a failure transfer from one to the other is automatic and instantaneous EATON CORPORATION UPS and Power Quality Products Catalogue Airflow management and racks Aisle containment Industry studies indicate that an estimated 60 of the cool air supplied to traditional data centres is wasted because it bypasses the intended IT equipment and returns directly to the hot air intake of the CRAC Adopting a cold or hot aisle containment strategy increases air efficiencies allowing a significant reduction of cold air supply translating to longer hardware life and valuable energy savings Eaton s solutions can be equally effective for both hot and cold aisles in the data centre Rack Integrated System End of Row Doors create more efficient cold aisles by blocking an obvious cold air escape route and entry for hot air re circulation and air mixing This allows you to set a higher overall temperature within the data centre thus saving energy and extending hardware life Eaton s ceiling system is comprised of clear panels made from materials with multiple ratings including UL94 V 0 ASTM E 84 FM4910 or antistatic These panels mount easily to the top of Paramount Vantage S2 and third party enclosures The ceiling system is modular and scalable to accommodate differences in rack h
Download Pdf Manuals
Related Search
Related Contents
カタログPDF Guide utilisateur de QGIS Mode d`emploi du Sérum Physiologique Physiologischen warning - Hawkins Equipment Samsung Monitor LED de 24" con diseño acabado en negro brillante Manual de Usuario here to Ultimate Box User Manual pdf User`s Manual Customer should know the following: 第Ⅴ編 ユーザマニュアル Copyright © All rights reserved.