Home

4107Q-en standard

image

Contents

1. lt gt 255 CH3 Green 0 100 0 lt gt 255 CH4 Blue 0 100 0 lt gt 255 CH5 Strobe 0 100 0 lt gt 255 AR2S Chanel Function amp Effect DMX Value CH1 Dimmer 0 100 0 lt gt 255 CH2 Red 0 100 0 lt gt 255 CH3 Green 0 100 0 lt gt 255 CH4 Blue 0 100 0 lt gt 255 CH5 Cool White 0 100 0 lt gt 255 CH6 Strobe 0 100 0 lt gt 255 HSV Chanel Function amp Effect DMX Value CH1 HUE 256 colors 0 100 0 lt gt 255 CH2 Saturation 0 100 0 lt gt 255 CH3 Value 0 100 0 lt gt 255 PART 3 Display Panel Operation 3 1 Display panel menu instruction Del MODE UP DOWN ENTER MODE menu selection or return to previous menu UP press UP through the menu list to increase change the value of the current function DOWN press DOWN through the menu list to decrease change the value of the current function ENTER confirm amp quit out current function setting 10 3 2 DMX512 address set DMX Press MODE until d 001 and then press UP DOWN to set DMX address between d 001 d 512 press ENTER to save 3 3 ID address set ID Press MODE until ID OO use UP DOWN to select ID address between ID 00 ID 50 and then press ENTER to save If ID address is 0 the 9th channel will out of function 3 4 Auto program parameters set AUTO Press M
2. to use the original packaging in which the product left the factory Shields lenses or ultraviolet screens shall be changed if they have become damaged to such an extent that their effectiveness is impaired The lamp LED shall be changed if it has become damaged or thermally deformed PART 2 INSTALLATION 2 1 Mounting 2 1 1 Hanging The product can be mounted in a hanging position using the supporting bracket The bracket should be secured to the mounting truss or structure using a standard mounting clamp Please note that when hanging the unit a safetv cable should also be used 2 1 2 Upright The product can be mounted in an upright or sitting position using the supporting brackets NOTE The product can be mounted at anv angle and in anv position It is possible to further adjust the angle of the product using the two adjustment knobs located on the side of the fixture 2 2 SETTING UP WITH A DMX512 CONTROLLER 2 2 1 DMX512 ADDRESSING WITHOUT ID ADDRESSING e Connect the DMX512 controller to the units in series e Each unit has 10 DMX channels so the DMX Addresses should increase by increments of 10 e g 1 11 21 31 e The ID address has not been set so therefore when using the controller CH10 must be inactive CH10 0 4 e Each DMX Address may be used as many times as required e Any DMX address in the range from 001 to 512 may be used 2 2 2 DMX512 ADDRESSING WITH ID ADDRESS 6 Connect the DMX512 controller to t
3. ODE until AUTO to run preset programs 8 programs selectable The default situation is run all 8 preset programs in recycle and these programs could be turned off after some parameters are changed Press MODE until AUTO and then use UP to select 8 preset programs and use DOWN to set these 8 programs ON OFF 3 5 Master Salve machine set MASTER SLAVE Press MODE until MAST Master machine or SLAV Slave machine to enter Master Slave edit menu Press ENTER to select Master or Slave fixture 3 6 White Balance fine adjustment instruction UP j RIABBS Vv f ma Alea ogs m tt X oog JCE XUDD bid5b Wess j 3 7 Displav Menu instruction general E3 Py E gt E3 An ea CE ILI EJ Je Col LA FU 2 gt Eetjelelelenv LAY GC GE OE C OS e ae Return up menu No In main menu cI 12 Part 4 Troubleshooting Phenomenon Solution The fixture does not work No light out Check main power fuse amp power cable connection Measure main voltage on the main connector No display Check connection of display PCB Replace a new display No responding to DMX controller Check working mode setting on display is DMX mode or not Check whether the unit be s
4. ORE OPERATION PLEASE CONFIRM THAT THE POWER SUPPLY STATED ON THE PRODUCT IS THE SAME AS THE MAINS POWER SUPPLY IN YOUR AREA This product must be installed by a qualified professional Always operate the equipment as described in the user manual A minimum distance of 0 5m must be maintained between the equipment 5 and combustible surface The product must always be placed in a well ventilated area Always make sure that the equipment is installed securely DO NOT stand close to the equipment and stare directly into the LED light source Always disconnect the power supply before attempting and maintenance Always make sure that the supporting structure is solid and can support the combined weight of the products The earth wire must always be connected to the ground Do not touch the power cables if your hands are wet ATTENTION This product left the place of manufacture in perfect condition In order to maintain this condition and for safe operation the user must always follow the instructions and safety warnings described in this user manual Avoid shaking or strong impacts to any part of the equipment Make sure that al parts of the equipment are kept clean and free of dust Always make sure that the power connections are connected correct and secure If there is any malfunction of the equipment contact your distributor immediately When transferring the product it is advisable
5. et as SLAVE Check DMX address settings Check DMX cable and it s connection Try to use another DMX console Signal error while use DMX Check whether DMX cables be connected well or not Check whether the DMX cable has to be terminated with a terminator to reduce signal errors If not please Solder a 120 ohm 1 4W resistor between pin 2 DMX and pin 3 DMX into a 3 pin XLR plug and plug it in the DMX output of the last fixture Part 5 Maintenance The cleaning of internal must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture s optics ix Clean with soft cloth using normal glass cleaning fluid ix Always dry the parts carefully jix Clean the external optics at least every 20 days yx Clean the internal optics at least every 30 60 days Up to vary products Please ask professional technical to clean waterproof products and make sure the fixture will be reassembled well for waterproof 13
6. he units in series e Each unit has 10 DMX channels so the DMX Addresses should increase bv increments of 10 e g 1 11 21 31 e Each DMX Address may be used as many times as required Any DMX address in the range from 001 to 512 may be used e Each DMX address may carry up to 50 separate ID addresses ID should be set in the menu on each unit in ascending values i e 1 2 3 e ID addresses are accessible from Ch10 on the DMX512 controller Example DMX ADDR 001 DMX ADDR 001 DMX ADDR 001 DMX ADDR 010 DMX ADDR 010 DMX ADDR 010 ID ADDR 01 ID ADDR 02 ID ADDR 03 ID ADDR 01 ID ADDR 02 ID ADDR 03 DMX512 CONTROLLER The figure above shows a simple DMX lavout which has used three units at each DMX address The three units have different ID addresses which allows the user to collectivelv control the whole group of units at that DMX address by setting CH10 to 0 4 or to control each unit independently by first selecting the DMX address and then by using CH10 to locate the target ID address 2 2 3 DMX channel list STAG Chanel Function amp Effect DMX Value CH1 Dimmer 0 100 0 lt gt 255 CH2 Red 0 100 0 lt gt 255 CH3 Green 0 100 0 lt gt 255 CH4 Blue 0 100 0 lt gt 255 CH5 Cool White 0 100 0 lt gt 255 0 lt gt 5 No function 6 lt gt 40 Red 41 lt gt 76 Green CH6 Color Macro 77 lt gt 112 Blue 8 preset color effect 113 lt gt 148 Yellow 149 lt gt 184 Cyan 185 lt g
7. i Ghine 4107Q Quad Color Spot USER MANUAL Thank vou verv much for choosing our product For safetv purpose please read this manual carefully before your operation This manual included installation and using information Please install and operate it according to this manual 4107Q V2 0 20120318 Indexing Part 1 Product GENERAL 1 1 PRODUCT INTRODUCTION 1 2 PRODUCT FEATURES 1 3 TECHNICAL SPECIFICATIONS 1 4 EXPLODED VIEW 1 5 DIMENSION 1 6 SAFETY WARNING PART 2 INSTALLATION 2 1 MOUNTING 2 2 SETTING UP WITH A DMX512 CONTROLLER 2 2 1 DMX512 ADDRESSING WITHOUT ID ADDRESS 2 2 2 DMX512 ADDRESSING WITH ID ADDRESS 2 2 3 DMX CHANNEL INSTRUCTION PART 3 DISPLAY PANEL OPERATION 3 1 DISPLAY PANEL MENU INSTRUCTION 3 2 DMX512 ADDRESS SET DMX 3 3 ID ADDRESS SET ID 3 4 AUTO PROGRAM PARAMETERS SET AUTO 3 5 MASTER SLAVE MACHINE SER MAST SLAVE 3 6 WHITE BALANCE FINE ADJUSTMENT INSTRUCTION 3 7 DISPLAY MENU INSTRUCTION GENERAL PART 4 TROUBLESHOOTING PART 5 MAINTENANCE Part 1 Product 1 1 Product introduction This product is designed for outdoor use Suitable applications include wash or effect lighting for architectural stage or nightclub applications This product can also be installed for use in signage and advertising using the dynamic functions available with DMX512 control Direct input of DMX512 signal allows the units to be controlled from any DMX512 controller This p
8. roduct can be operated as a single unit or in multiple units for large applications 1 2 Product Features Optical system 1 256 grades electric adjustable mini within 100ms Strobe at same step speed adjustable strobe Cooling system Heat cycle cooling system with strong direct air Operation mode Standard DMX512 signal 3 4 5 6 10 channels 8 modes Intelligent ID addressing separately Intelligent ID group addressing Auto mode Master Slave Mode Display panel 4 LED digital display DMX address code test or play auto programs Auto mode 8 preset color change programs 1 3 Technical Specifications Voltage AC90 250V 50 60Hz IP rating IP65 Power 130W Light Source 12PCS 10W RGBW Quad Color LED Lifespan around 50 000 hours rated by led lamp factory Beam angle 20 30 40 60 up to order Net Weight 4 2kg Size 180 260 300mm 1 4 Exploded view 4 5 6 N kal ITEM DESCRIPTION ITEM DESCRIPTION 1 Glass cover 9 Side cover 2 Lens panel 10 Arm screw 3 Lens 11 Metal case 4 Led lamp 12 Displav PCB 5 Led lamp plate 13 Waterproof signal connector Metal plate for power 6 supply 14 Waterproof power connector 7 Power supply 15 bracket 8 Main PCB 16 1 5 Dimension B kd EJ o kl e R e 205 00 1 6 Safety Warning IMPORTANT ALWAYS READ THE USER MANUAL BEF
9. t 220 Purple 221 lt gt 255 White GH eb 0 lt gt 255 Strobe speed from slow to fast 0 lt gt 5 No function 6 lt gt 36 Program 1 37 lt gt 68Program 2 69 lt gt 100 Program 3 CH8 Auto program 8 programs 101 lt gt 132 Program 4 133 lt gt 164 Program 5 165 lt gt 196 Program 6 197 lt gt 228 Program 7 229 lt gt 255 Program 8 Program run speed CH9 from slow to fast 0 lt gt 255 0 lt gt 4 No Function CH10 ID address 0 50 Group 5 lt gt 255 D 1 50 ARC Chanel Function amp Effect DMX Value CH1 Red 0 100 0 lt gt 255 CH2 Green 0 100 0 lt gt 255 CH3 Blue 0 100 0 lt gt 255 ARC2 Chanel Function amp Effect DMX Value CH1 Red 0 100 0 lt gt 255 CH2 Green 0 100 0 lt gt 255 CH3 Blue 0 100 0 lt gt 255 CH4 Cool White 0 100 0 lt gt 255 ARCD Chanel Function amp Effect DMX Value CH1 Dimmer 0 100 0 lt gt 255 CH2 Red 0 100 0 lt gt 255 CH3 Green 0 100 0 lt gt 255 CH4 Blue 0 100 0 lt gt 255 AR2D Chanel Function amp Effect DMX Value CH1 Dimmer 0 100 0 lt gt 255 CH2 Red 0 100 0 lt gt 255 CH3 Green 0 100 0 lt gt 255 CH4 Blue 0 100 0 lt gt 255 CH5 Cool White 0 100 0 lt gt 255 ARCS Chanel Function amp Effect DMX Value CH1 Dimmer 0 100 0 lt gt 255 CH2 Red 0 100 0

Download Pdf Manuals

image

Related Search

Related Contents

BILAN THROMBOSE  Istruzioni per l`uso  FICHE PRODUIT SUPRALAINE  MANUAL DE USUARIO DEL ECONOMIZADOR  CyberPower CP-H420PS Computer Drive User Manual  フロンガス分析器 品番 URI-700H 混合冷媒の比率が分かる!  edital de pregão presencial nº 048/2007/sad  Xerox® Device Agent Guia do Usuário  Samsung LED Business Monitor 24"  ESP180 Time Stamp User Manual  