1. Skin Rejuvenation 1 Clean the operation position 2 With cold gel 3 E Light 480 Wavelength handle operation Spear head close to the skin epidermis the spot position next to a part to play From chin to cheek and forehead hit back and forth for 3 to 5 times 4 Apply a thick layer of cold gel 10 minutes clean is ok Repair the growth factor JU Acne Therapy 1 Clean the operation position 2 With cold gel 3 E Light 480 Wavelength handle operation Spear head close to the skin epidermis the spot position next to a part to play From chin to cheek and forehead hit back and forth for 3 to 5 times 4 Acne appear reddish is preferred 5 Apply a thick layer of cold gel 10 minutes clean is ok Repair the growth factor T Vascular Therapy 1 Clean the operation position 2 With cold gel 3 E Light 530 Wavelength handle operation Spear head close to the skin epidermis the spot position next to a part to play From chin to cheek and forehead hit back and forth for 3 to 5 times 4 Vascular become deep red 5 Apply a thick layer of cold gel 10 minutes clean is ok Repair the growth factor TX Note all items after 24 hours can not contact with hot water not exposure sauna cooperate to repair growth factor repair skin avoid backflow phenomenon of pigment E light hair removal procedures Step clean thoroughly clean the dirt or cosmetic treatment area in order to prevent the influence of skin absorption of light energy Step2 clip with o
2. according to the actual status apply to re send a completely new device back to our client B We won t supply maintaining guarantee if troubles as below a Disassembling the machine by self b Fall it without caution c Lack of reasonable keeping and protect d Not operate according to the user manual e Expendable reasons If changes of the design and specification of the machine we will not notice you in addition If any queries please feel free to contact with the local marketing company All in one we will try our best to serve you and also need your fully cooperation Thanks Accessories List Name number note Laser handle 1 E light handle The power cord Open the key Water injection funnel Eye mask The guest to use Safety glasses N The operator use Product name Purchase date deadline Seller Add Tel Customer Add Tel Repair date Reason f f f of the fault Repair content Maintain list
3. Color Gece 6 8 20 removal Color simple 7 5 8 0 panen oT 25 Color deep 6 8 7 4 Color simple 7 5 8 0 Therapy IPL POWER 15 began to add up 15 began to add up 15 began to add up 15 began to add up Wrinkle Partial white 7 a 3T 2S moderation 7 Partial black 6 0 6 5 15 began to add up 20 30 i Partial white 7 5 8 0 10 Rejuven 3T 2S moderation 7 0 7 5 20 i Partial black 6 0 6 5 30 10 20 30 Therapy moderation 7 0 7 5 Partial black 6 0 6 5 Note child pulse width reduction based on the first pulse width can be 0 5 such as the first pulse width is 7 0 pulse width should be 6 5 times pulse width is fixed in 5 0 no need to adjust E Light operating steps Wrinkle Removal 1 Clean the skin 2 Operating parts evenly cold gel 3 E Light 530 Wavelength handle operation Spear head close to the skin epidermis the spot position next to a part to play 4 Repeat 3 times until you see skin pigment deepen mentioned is preferred 5 Apply a thick layer of cold gel for 10 minutes or so clean Repair the growth factor gt Hair Removal 1 Trim the hair 1 2mm gt 2 clean 3 apply a layer of cold gel 4 E 3 640 Wavelength handle operation Spear head close to the skin epidermis the spot position next to a part to play gt 5 From 3 to 5 times See hair small roll or smell a Mao Jiao is ok 6 Apply a thick layer of cold gel 10 minutes clean is ok Repair the growth factor
4. Maintenance The term of maintaining guarantee is main device year and spare part 3 months from the date of purchasing according to the receipt Expendable is not included in it Others not included in maintaining guarantee or over the time we also supply to maintain and renew but need charges Please contact with the dealer if need change of purchasing the parts and easily expendable products A We will guarantee the quality of our equipment normally there is no quality problem 1 If there is a deficiency please email or call us on the reasons it would be best to dealt with by emailor telephone Because some of the problems are caused by using the machine in a wrong way 2 We suggest the client to take photos of the area where the problem occurs we will pass them to our technician our technician will give a satisfactory answer within 1 7 working days 3 If the problem comes from the spare part within the warranty we could consider in changing the spare part to our client which could be sent with his her next order If the next order is uncertain we could pay freight cost to send the spare parts 4 If the problem comes from the main device within the warranty we could advice our client to post the device back to our company for repair by ordinary post or we could re send a new one to our client If the cost of posting the problematic device back to BEST is more than the value of a new device BEST would take it into consideration
5. E Light Laser Beauty System User manual RL EL Before Using 1 Check that the machine s electrical supply is connected correctly to the power supply before using 2 Before starting the machine fill up the water tank with distilled water by attaching the funnel Into the Water Inlet Hole and adding distilled water 3 Use only distilled water Do Not use mineral water or tap water Note Trying to operate the machine without water is Prohibited In the case of running without water 1f Cryo head shatters the user bears the cost 4 Fill the distilled water into the machine by the Water Outlet Hole and fill until water starts to overflow out from the Over Flow Hole water capacity 3 4 liters 5 Disassembling this machine is Prohibited without the manufacturers prior permission 6 Put the working handle on fixture avoid broken after operation if the machine monitored temperature is rising or if water purity is compromised 7 Check and change cooling water every month more frequently if the machine is being used heavily or the funnel Into the Water Inlet Hole and adding distilled water 8 Allow the water pump to run for one minute before commencing client service 9 Ensure the machine electrical supply is earthed This product does not belong to medical please don t use for disease treatment E light laser parameter Th Protect haw manage of The first pulse width interval project i l 6 8 7 4 Hair ST 25
6. er mouth vent plug removal it is strictly prohibited in a heat source for operation laser operating steps project Power frequen cy RR black handle 550mm Add energy begins to according to 4 5 the strength up 1064 The silver circle lenses 550mm Add energy begins to according to 4 5 handle gt the strength up 532 Gilver fang lenses handle 550mm Add energy begins to according to 4 5 the strength up Multifunctional machine Therapy Mode Power EE sl B Direct Light 2 I A Laser project operation skill 1064mm handle 1 Adjusting the energy begins to used laser alignment operation areas about 10 cm 2 A place next to a part to treat until see micro ooze blood Repair the growth factor 532mm handle 1 Adjusting the energy begins to used laser alignment operation areas about 10 cm 2 Aplace next to a part to treat until see micro ooze blood Repair the growth factor Black doll handle 1 Spray machine spray for 10 minutes or apply moisturizing film for 10 minutes 2 Clean the treatment position 3 Evenly medical carbon powder 8 10 minutes or so let it absorbed into the pore 4 Adjusting the energy begins to used laser alignment operation areas about 10 cm A place next to a part to treat until the toner into smoke disappear 4 Cleaning with foam cleanser twice Repair the growth factor Note 1064mm 532mm handle treatment cannot touc
7. h water in 48 hours vervet doll spear 24 hours disappeared after treatment do not contact with hot water and used with repair of growth factors The advantage of the laser system 1 adopt the gem tuning Q mode 10 20 ns pulse width 2 patent seismic ceramic diffuse gun good stability 3 special YAG crystal excellent single pulse energy of up to 200 mj multiple pulse energy is up to 1200 mj 532 nm laser dispel red base 1064 laser dispel black base whiten and tender skin vervet doll treatment head with carbon powder treatment 4 dedicated high quality accessories such as pulse xenon lamp high power laser pump to ensure the quality of the instruments and continuous workability Scope of application of laser systems Is mainly used to remove part of endogenous pigmentary skin lesion exogenous pigmentary problems and traumatic pigmentation of the skin 1 endogenous skin pigmentary lesions nevus of ota ITO hemorrhoids Mongolia spot zygomatic department brown blue nevus coffee spot treatment has the certain difficulty need more than one course of treatment repeatedly and poor patients postoperative satisfaction seborrheic keratosis against border nevus melanosis blue nevus pigmentation after inflammation part of chloasma 2 exogenous pigment skin problems tattoos eyebrow tattoo tattoo lip lines and the treatment of traumatic tattoo pigment skin lesions such as have good clinical effect After sale Service And
8. ne time pruning tools clip hair removal parts of the hair stay 2 3 mm long hair shaft Clip before you clean your skin where the hair removal with physiological saline Step3 operating in the area of hair removal apply a thin layer of cold gel cooling effect that protect skin Step4 daub after treatment to repair the growth factor repair skin or to daub a layer of cold gel hair removal parts will produce a tiny red spot had mild burning sensation this is belongs to the normal reaction usually at the end of the treatment with 1 2 hours will disappear Acne therapy Wrinkle Removal wrinkle removal 5 er Vascular therapy Skin r on Hair Removal E light spot operating procedures 1 Clean 2 apply cold gel medium not gel blot out the more the better a thin layer can 3 seta good clean energy operation 4 Toning 5 apply the membrane sea bath or collagen 6 daub fiber growth factor 7 Embellish skin on the other hand the essence cream etc 8 If burns can choose ice The interface diagram and parameters adjustment Instrument operation procedures 1 must use distilled water or pure water add water to vent out of the water 10 days in water at a time 2 every time after adding water spear should be placed on the ground the water cycle for five minutes 3 instrument temperature should not exceed 50 C 50 C after the instrument shall stop working and change of water 4 operation and instruments of wat