Home

DG-30 Digital Keypad / Proximity Entry system Operation User`s

image

Contents

1. 001 100 A Green light comes on This slot position is ready to register the card 1 Present card in front of the reader gt Yellow LED blinks beep gt enrolled completed gt repeat 2 Present card in front of the reader gt 3 audible beeps another card has already been input duplicate card B Red light comes on This slot already has a code registered 1 Press x x deletion gt Green light gt Enter the slot position code again gt Present the card in front of the reader gt same as Step A 2 Enter another slot card position Add PIN codes and deletion Enter the Programming mode Enter the slot position code 101 150 A Green light comes on This slot position code may register the PIN codes Input 5 digit PIN codes gt Yellow LED blinks beep gt enrolled gt repeat B Red light comes on This slot position code is registered 1 Press x gt deletion gt Green light gt Press the slot position code again gt Input 5 digit PIN codes gt same as Step A 2 Enter another slot card position Note 1 The codes 12345 or master code are not be used for PIN code l random codes gt gt gt gt gt 5 digit PIN codes Enter To Program Relocking Timer Enter the Programming mode A Relay 1 Press x10 Followed by the number of seconds the relay should open 05 5 seconds 01 99 seconds beep enrolled Press to exit from the programming mod
2. master is 12345 2 beeps and the Yellow LED will light up you are now in the programming mode 2 Note After 60 seconds if you have not entered any codes or data the system will automatically exit from the programming mode After 6 wrong attempts at the master code the lockout facility will operate Exiting from the program mode 1 Press to exit from the programming mode 2 Note After 60 seconds if you have not entered any codes or data the system will automatically exit from the programming mode After 6 wrong attempts at the master code the lockout facility will operate Selecting The User Format Enter the Programming mode Press 301 Followed By 01 This will set the system to be used as Wiegand 26 bit Slots 001 100 for cards tokens and slots 01 150 for PIN codes This will set the system to be used as Wiegand 34 bit Slots OR Followed By 02 001 100 for cards tokens and slots 01 150 for PIN codes OR Copyright Gianni Industries Inc All Rights Reserved P MU DG30 Ver A Publish 2004 08 26 Page 2 4 G EM GIANNI INDUSTRIES INC Followed By 03 This will set the system to be used as Slots 001 150 for PIN codes only Note When system format has the change there s a possibility the card stored would be invalid Please reset the system and input all cards tokens Add card and deletion Enter the Programming mode Enter the slot position code
3. or PIN codes attempted EPROM Non volatile memory System will retain all programs and codes after a total loss of power Output Dual relay N O N C Com Output free voltage contact gt Tamper switch Relay Activation Time x10 x20 E Strike Time 1 99 seconds adjustable m Strike mode Access Timer or Latch Color Dark gray Beige White Copyright Gianni Industries Inc All Rights Reserved P MU DG30 Ver A Publish 2004 08 26 Page 1 4 G EM GIANNI INDUSTRIES INC 3 The indicator signal chart Sound and LED indicator Red LED Power on Green LED Relay activated LED signal Tri color e low Entering the Program mode Tri color Red Slot position is registered Tri color Green Slot position is ready to register 1B Slot position is ready to register gt Effective card PIN eep codes gt Exit from the Program mode 2 Beeps Entering the Program mode Sound signal c Slot position is registered gt Data computing error gt other 3 Beeps f operation mistakes gt duplicate card 5 Beeps Master Code reset to Factory 12345 Factory Parameter list Format 26 bits Card register None Master Codes 12345 5 digits Strike Time 1 seconds Pressed key delay time Time Out 5 seconds Program mode delay time 60 seconds Invalid PIN Lock out time 60 seconds 4 Operation Instruction Enter Program Mode 1 Compose twice the master code Factory
4. G EM GIANNI INDUSTRIES INC 1 Product Characteristic HH HHH HHH HHHON Se oe oe i tn OF DG 30 Digital Keypad Proximity Entry system Operation User s Manual Allows up to 150 Proximity cards tokens or PIN codes Tamper Switch Included Door Reed Switch Input for Anti Trailing Fully Programmable via keypad and master code Extendable from keypad only to proximity controller Supports 26 or 34 bit Wiegand auxiliary reader Logical memory to prevent duplication Non Volatile Memory Invalid PIN Lock out Specifications Operating Voltage 12 Vdc Current Draw 60mA Max 12VDC Input request to exit time out reed switch contact auxiliary reader Relays Electric Current 2A MAX 30Vdc 0 4A 120Vac Memory Volume 150 PIN codes or 100 Proximity cards tokens and 50 PIN codes Format 26 or 34 bit Wiegand hexadecimal Relay 1 is controlled by 001 100 user slots Cards or PIN codes Relay 2 is controlled by 101 150 user slots PIN codes PIN codes 5 digit codes only Case Material ABS UL94V0 Operating Temperature 20 70 C Ambient Humidity 5 95 relative humidity non condensing Visual Signals E Red Power on E Green Relay activated E Tri color LED Yellow Program Mode Red The slot is registered gt Lock out Green This slot may register the card or PIN codes Factory Master Code 12345 Invalid PIN Lock out The system will shut down for 60 seconds while 32 codes of incorrectly Master Codes enrolled
5. e or program other operating B Enter 00 Sets the relay to latching mode Correct code entered opens the relay and the relay stays open until the correct code is entered again C Relay 2 Press x20 Followed by the number of seconds the relay should open 05 5 seconds 01 99 seconds beep enrolled Press to exit from the programming mode or program other operating D Enter 00 Sets the relay to latching mode Correct code entered opens the relay and the relay stays open until the correct code is entered again Changing the Master codes Enter the Programming mode Enter 00 Followed by the new 5 digit master code beep enrolled gt Enter to exit from the programming mode or program other operating Copyright Gianni Industries Inc All Rights Reserved P MU DG30 Ver A Publish 2004 08 26 Page 3 4 G EM GIANNI INDUSTRIES INC Reset to Factory m Master Code reset to Factory 12345 Insert the jumper RES1 gt 1 2 position gt 5 audible beeps gt Reset successful gt Return Insert the jumper to 2 3 position a Remove all stored information Insert the jumper RES1 gt 1 2 position gt 5 audible beeps Master Code reset to Factory 12345 gt after 5 seconds gt 5 audible beeps gt Remove all stored information gt Return Insert the jumper to 2 3 position Note If you only wish to reset the Master Code to the Factory default remove the jumper after exactly 5 a
6. udible beeps otherwise all cards codes will be deleted 5 Wiring diagram Auxiliary Reader Wiegand 26 or 34 bit Format Auxiliary Reader Data CLK Format Contact door reed switch i This reed switch is used to reset the re locking time to 0 second when the door is moved Using N O contact in case of door closed changeover to N C When door is moved N Ne LOCKING DEVICE Power Supply Note Tamper Switch To follow the precedent of Group 1 contacts Re set of all system parameter DG 30 controller and auxiliary reader distance must not exceed 20 meters the data will not transmit beyond this The suggested wire gauge is 22 26 AWG Using a Linear supply power recommended to prevent power reduction at the card reader The varistor or diode must be connected across the lock terminal electromagnet operated by the device The vartistor controls the overload produced by the strike coil EMP Egresses switch should be N O type Copyright Gianni Industries Inc All Rights Reserved P MU DG30 Ver A Publish 2004 08 26 Page 4 4