Event Link for Honeywell Galaxy 1.1 User Manual

image

Contents

1. 4nnnr a Figure 2 Field for entering the IP address for the Honeywell Galaxy Panel e Configure the Gateway IP address 56 4 01 3 and the subnet mask 56 4 01 4 e Configure the Ethernet reporting format to SIA level 4 highest level possible 56 4 02 1 e Set all the triggers on that are needed to be received as events in the Milestone Alarm Manager 56 4 02 1 1 e Configure the Alarm reporting Primary IP address 56 4 02 2 1 so the IP address matches the IP address of the computer running the Milestone XProtect Event Server e Configure the Primary Port Number 56 4 02 2 2 The port must be set to 10002 If use of another port is required please consult the Advanced configuration NB The firewall must allow TCP communication to the specified Port 10002 Create an account number necessary for the panel to send alarms 56 4 02 4 Configure the receiver to 1 Single 56 4 02 5 Configure the protocol to 1 TCP 56 4 02 8 Configure the remote access time to 4 Any time 56 4 03 1 and the mode to 1 Direct Access 56 4 03 2 e Configure the SIA Control IP Address 56 4 08 so the IP address matches the IP address of the computer running the Milestone XProtect Event Server Disable all encryption on the panel 56 4 09 1 0 to 56 4 09 4 0 Leave the Engineer mode by pressing Esc a number of times until the keypad displays the galaxy version Configure the Panel using the RSS applica
2. Logs Navigation Window nx futu DA Danish Denmark Help Dm SZ g Si 4 General Remote Access Reporting Triggers User Codes p s System Users Alarm Reporting Zones Format SIA hd Zones Level Assemble Zones Receiver SINGLE z Oupus dl Protocol TCP RIO Outputs Keypad Outputs Schedule Output HEP 100 Header Outputs Primary P Address 10 100 0 82 Group Mode Primary Port Number 10002 Group Parameters Group Communications Secondary P Address Secondary Port Number 0 i Links Alam Monitor C icati Alarm Monitor Internal Telecomms Port Number 0 External Telecomms ISDN Ethernet Intarnal BECH Account Number Figure 4 The Ethernet Reporting tab in the Honeywell RS v6 application In order to receive event notification for the Honeywell Galaxy Dimension Panel the Reporting settings must be configured as the following Format SIA Level 4 Receiver Single Protocol TCP Account e g 0 running the Milestone XProtect Event Server Primary IP Address e g 10 100 0 82 The IP address must match the IP address of the computer e Primary Port 10002 see Advanced configuration for how to select an other port on the Milestone XProtect Event Server NB The firewall must allow TCP communication to the specified Port e The Alarm Monitor section should be empty Ethernet Triggers tab Check all the events triggers that should be processed by the Milestone Honeywell Galax
3. eeeeeeeeseseees essen eene nnne nn snnm nn nnn n inta inan tasas nasa nn nns 15 Mapping of evernis 1 Licinia reete cue necc cre sue unnn nenna nnmnnn nannan nnmnnn aue ec eu ennan Es 16 www milestonesys com Page 3 Contents Setting up the Milestone XProtect Smart Client c eese 19 xus E H 20 GOUPS U M BR 20 EOD E 21 OD DEE 21 Example of generating a Milestone Event eese 22 TROUBLESHOOTING GUIDE 5 rarae ccn xs abico napa on ennu EE anc enu 24 The panel will not connect to the Honeywell Galaxy panel 24 No event are received E 24 KNOWN ISSUES T 25 ADVANCED CONFIGURATION ee ceeeeeeeeee nn 26 www milestonesys com Page 4 Contents Copyright Trademarks amp Disclaimers Copyright 2013 Milestone Systems A S Trademarks XProtect is a registered trademark of Milestone Systems A S Microsoft and Windows are registered trademarks of Microsoft Corporation All other trademarks mentioned in this document are trademarks of their respective owners Disclaimer This document is intended for general information purposes only and due care has been taken in its preparation Any risk arising from the use of this inform
4. Target Audience for this Document This document is aimed at system users and describes the integration between Honeywell Galaxy Dimension and Milestone Basic knowledge of the Milestone XProtect surveillance software is required High knowledge of the Honeywell Galaxy Dimension Panel usage is required www milestonesys com Page 2 Target Audience for this Document Contents COPYRIGHT TRADEMARKS amp DISCLAIMERS 5 eodd M Y 5 Hir urucm e 5 sise UE 5 GENERAL DESCRIPTIO DL nae ataai uu gege ege Genee 6 Juge DL d E 6 Solution oVervVieW D 6 acudelijlc 7 INSTALLATION e 8 Ei t 8 CONFIGURATION eegene indu ings Elsass er uS uS caiS nnmnnn dais 9 Honeywell Configuration eeeeeeeeeeieeeeese sienne nennen nena asina nasa natns nsn nass cn nn nennen nn enu 9 Configure the Panel using the Key Pad 9 Configure the Panel using the RSS application 10 EE ER mE 10 Ethernet Reporting 1aD 02220022029299009209 E nennen ennemis 11 Ethernet Triggers tab eet rette etae rerba rid dde hanes evi aad 12 Milestone VMS veri iecur LI IM dui UI ect 12 Panel Information EE 13 PANeIDeTAIS cC M 14 MIP SECUI a 14 OPERATION m 15 Setting up Milestone MAP
5. 1011 c6gltFinal SPARE aypa 1012 spot SPARE Custom SIA Schedule Output 1013 cBgltlntruder SPARE Activity Monitor EE ue 1014 cBgliHous24 SPARE Groups aj 1015 cgliSecuip010 SPARE Res Select System H m LE E ae ete Group Fara 1018 LOCA SPARE Group Communications E NEN Notes Links Communications Internal Telecomms External Telecomms poe Acc Name Milestone acc Num Panel Type Galaxy 520 Panel Version 6 50 Comm Medium Direct Comm Ste Figure 15 The General tab in the Honeywell RSS V6 application 2 Take notice to the No 1004 and the Function selected INTRUDER as they are to be used as part of the configuration on the Milestone VMS system These will naturally change based on the zone and the function configured Please note that this Zone is configured to Group A1 in this case meaning that group A1 must be in set state in order for this zone to trigger the intruder alarm 3 Here is the needed alarm definition in the Milestone VMS in order to trigger an alarm based on the intruder alarm from the Honeywell Galaxy Panel HoneyWell Galaxy Intruder Alert Honey Well Galaxy Intruder Alert This alam is originating from a HoneyWell Galaxy system l Smart Client Profiles Matrix D Rules and Events E Rules Time Profiles E Notification Profiles R User defined Events X Analytics Events Operator action required Time limit Events triggered Oth
6. 24 HOURS ATM 1 Burglary ATM 1 zone alarm 24 HOURS ATM 2 Burglary ATM 2 zone restored 24 HOURS ATM 2 Burglary ATM 2 zone alarm 24 HOURS ATM 3 Burglary ATM 3 zone restored 24 HOURS ATM 3 Burglary ATM 3 zone alarm 24 HOURS ATM 4 Burglary ATM 4 zone alarm 24 HOURS ATM 4 Burglary ATM 4 zone alarm 24 HOURS URGENT Burglary Urgent zone restored 24 HOURS URGENT Burglary Urgent zone alarm 8 0MIT FORCE OMT Panic Unomitted after rearm ALWAYS ALM CAUSE AC Power Cause of alarm ALWAYS ARC TEST Tamper Test ARC TEST ALWAYS FIRE Fire GUI Fire Button restored ALWAYS FIRE Fire GUI Fire Button alarm ALWAYS internal to tel Communication Tel module lost RS485 ALWAYS internal to tel Communication Tel module rest RS485 ALWAYS MEDICAL Medical GUI Medical Btton Restr ALWAYS MEDICAL Medical GUI Medical Btton Alarm ALWAYS RECEN SET Closing Previous alarm was within 5 mins of set CUS ZONE CUSTOM A Burglary Custom A zone rest CUS ZONE CUSTOM A Burglary Custom A zone alarm CUS ZONE CUSTOM B Burglary Custom B zone rest CUS ZONE CUSTOM B Burglary Custom B zone alarm ELEC ST BATT FUSE Communication Battery Fuse restored ELEC ST BATT FUSE Communication Battery Fuse blown ELEC ST BATT LOW Communication Battery Low restored ELEC ST BATT LOW Communication Mod Battery Low rest ELEC ST BATT LOW Communication Battery Low
7. ELEC ST BATT LOW Communication Module Battery Low ELEC ST CU BATT Communication Control unit batt restore ELEC ST CU BATT Communication Control unit Battery Low ELEC ST FUSE A2P Communication NFA2P Fuse restored ELEC ST FUSE A2P Communication NFA2P Fuse blown ELEC ST LOW VOLTS Communication Module Low Volts rest ELEC ST LOW VOLTS Communication Module Low Volts ELEC ST MEMORY OK Remote Log Test Power Up ELEC ST TROUBLE RF BATLOW Wirelesss RF Battery Low Restrd ELEC ST TROUBLE RF BATLOW Wirelesss RF Battery Low ELEC ST AC FAIL AC Power AC Fail zone restored ELEC ST AC FAIL AC Power Module AC fail restored ELEC ST AC FAIL AC Power AC Fail zone trouble ELEC ST AC FAIL AC Power Module AC fail trouble ELEC ST CU FUSE AC Power Control Unit fuse rest ELEC ST CU AC AC Power Control Unit AC restred ELEC ST CU AC AC Power Control Unit AC trouble ELEC ST FUSE AC Power Audio fuse restored ELEC ST FUSE AC Power Audio fuse trouble Examples of valid mappings between the Honeywell Galaxy event and Milestone Alarms INTRUDER 24 Hours Security gt Burglary Intruder zone alarm gt Burglary 24 hours zone alarm gt Burglary Security zone alarm Fire gt Fire Fire zone alarm Tamper Tamper Lid Tamper alarm Tamper gt Tamper AUX Tamper alarm Setting up the Milestone XProtect Smart Client In the Smart Client all the defined Panels including their subscribed Groups Zones Outputs can be vis
8. Milestone VMS In order to use the plug in some settings must be configured using the XProtect Management Client Use Site Navigation and browse to MIP Plug ins gt Honeywell Galaxy Plug in gt Panels and add a new panel as shown here E System Log E Audit Log E Event Log E Rule Log H O Alarms G MIP Plug ins 3 0 Event Link for Honey Beie Bee Groups E Zones V Outputs Figur 6 The Honeywell Galaxy Plugin configuration in the XProtect Management Client Panel Information The following settings are required in order to establish connection to the Honeywell Galaxy system Name A unqiue identifier for the panel which is only used in the Milestone VMS IP Address The IP address of the remote Honeywell Galaxy system Port Number The port number used for communication with the Honeywell Galaxy system Pin The PIN code used for logging on to the Honeywell Galaxy system The P address must match the panels IP address KeyPad option 56 4 1 1 After the configuration press Connect to Panel and the plug in will retrieve the available zones groups and outputs from the Honeywell Galaxy system Note that the number of shown groups zones and outputs might exceed the number physically available on the Honeywell Galaxy system Please note that each panel must be given an unique IP Addr
9. Panel first Zones A zone is a representation of the Inputs or Alarms on the Honeywell Galaxy Dimension Panel There can be up to 520 zones The zones are named 1001 4158 A zone can be Enabled or Disabled Disabling a zone will set the zone in omit state on the Honenywell Galaxy system and will therefore ignore any alarm on that zone Enabling the zone will clear the omit flag again Outputs An output controls a device that can be activated or deactivated e g a Bell or a Horn There can be up to 256 outputs The outputs are named 1001 4154 An Output can be Activated or Deactivated Activating an output will trigger the output based on the settings configured on the Honeywell Galaxy Panel likewise will deactivate close an output Example of generating a Milestone Event In this example an intruder alarm will generate a Milestone event when intruder alarm triggers 1 Configure the intruder Zone on the Honeywell Galaxy Panel SE V6 App n Les Ele Edit View Connect Panel Communications Logs Help MSS Bim E ums EIDmEES T Sa Users aj 7 7 7 No Description Function P General Also Affects RF Zones User Codes E System Users E General Options al E ipti e Description Intruder gt MS Chime B Hash a Zones 1 Function INTRUDER Omit Star E Assemble Zones gt Outputs a 1007 SPARE Group Fat cM Fro Check RIO outputs We es ne Responso Tine e V
10. be a specific panel or All panels Alarm Definition Information I Alarm definition Enable 7 Name Intruder zone alarm Alert when a Intruder zone alarm is triggered gt Trigger Triggering event Honeywell Galaxy T Burglary Intruder zone alarm 7 Figur 10 Dialog for defining an alarm in the XProtect Management Client Mapping of events The follow event can be selected on the Honeywell Galaxy Panel and can be used for activation of alarms in the Milestone Alarm manager PA DURESS INTRUDER 24 Hours Security Custom zones Ser Fault Test Omit Tamper Setting Reset Cancel Module Comms Elec Status Menu Access Trouble Timers Log Zone Max Tag Zone Restoral Supervision Fault The zone events must be checked on the Honeywell Galaxy Panel in order for the Panel to send events to the Milestone Alarm Manager The zone events must be mapped to the individual zones in the Milestone Alarm Manager Tamper must be mapped to the panels The table beneat can be used to for mapping Honeywell Galaxy triggers to Milestone Event names Galaxy Trigger Function Galaxy Event Milestone Event Name 24 HOURS 24 HOURS Burglary 24 hour zone restored 24 HOURS 24 HOURS Burglary 24 hour zone alarm 24 HOURS ALARM EXT Burglary Alarm extend zone rest 24 HOURS ALARM EXT Burglary Extend zone alarm 24 HOURS ATM 1 Burglary ATM 1 zone restored
11. either using the Honeywell Galaxy Key Pad or the Remote Service Suite RSS Log in the Panel by entering the user pin code default 12345 on the Key Pad Press Enter a number of times until the key pad display shows the option menu Select the option menu 48 1 1 and press 1 Enter to enable the engineer access Press Esc until the option menu 10 setting reappears again Log in to the Panel using the Engineer pin code default 112233 Press Enter a number of times until the option menu is shown Configure the Ethernet remote Access mode to 3 Instant 47 4 1 and the Control Upload to 1 Eng Prog 47 4 5 Configure the Remote Maintenance to enable Code and Notice 47 4 6 2 2 1 e Configure the Restart language to English 51 17 3 1 e Configure the P address for the Honeywell Galaxy Dimension Panel 56 4 01 1 The Panel should be given a fixed IP address This IP address must match the P address in the Panel Information in the Milestone XProtect Manage Client Manage Application see Figure 2 Field for entering the IP address for the Honeywell Galaxy Panel s amp Milestone XP System Log Eq Panels General Settings Panel Details Audit Log lt p Panel 220 Name ES Groups Event Log Panel 220 Deeg IP Address Bowen 10 100 74 220 di MIP Plug ins enatis Ee Event Link for Honey Port Number El es Panels 10005 71 Groups PIN _ Zones 3 SS T Outputs
12. P The Primary IP Address and Port Number must match the IP Address of the computer running XProtect Event Server The Alarm Reporting Triggers must be enabled E g PA DUESS INTRUDER 24 Hours Security Fire Tamper Module Comms Elec Status Trouble Timers Fault An Alarm definition in the XProtect Management Client must be defined for the specific trigger The source of the Milestone event must match the trigger type Zone Group Panel Restarting the Milestone XProtect Event Server Known issues The Plug in does not support virtual zones 0011 0018 In rare cases the status monitoring in MAP will not reflect the state of the panel this can happen after adding a new panel Should this happen please restart the event server The Plug in does not support any encryption so all encryption KeyPad 56 4 09 1 56 4 09 4 must be set to off on the Honeywell Galaxy Panel The Plug in only supports communication in English when getting events from the Honeywell Galaxy panel KeyPad 51 17 3 1 Advanced configuration When installing the Event Link for Honeywell Galaxy plug in the configuration file EventLinkForHoneywellGalaxy dll config will be installed toghether with the plugin This file contains settings that under normal circumstances should not be altered The EventLinkForHoneywellGalaxy dll config file is a XML file that can manually be altered using a text editor like notepad lt xml versionz 1 0 encoding
13. ation rests with the recipient and nothing herein should be construed as constituting any kind of warranty Milestone Systems A S reserve the right to make adjustments without prior notification All names of people and organizations used in this document s examples are fictitious Any resemblance to any actual organization or person living or dead is purely coincidental and unintended This product may make use of third party software for which specific terms and conditions may apply When that is the case you can find more information in the file 3rd party software terms and conditions txt located in your Milestone surveillance system installation folder www milestonesys com Page 5 Copyright Trademarks amp Disclaimers General description Introduction This document describes the Event Link integration between Milestone XProtect and the Honeywell Galaxy Dimension 48 96 264 and 520 panels This integration supports groups zones and outputs on the Honeywell Galaxy box and on any connected RIO modules It provides the ability to listen to alarms on these and has the ability to enable and disable them In the same way it is possible to enable and disable the entire Galaxy panel If the panel is disabled the behavior on the Honeywell Galaxy system remains intact but control status monitoring and alarms are disabled in the Milestone VMS Enabling and disabling can be done through Milestone MAP icons for each of the types pan
14. el groups zones and outputs The icons will also indicate any unhandled alarms waiting for acknowledgement and will show the current status of the icon disabled enabled Please note that if an alarm is acknowledged in the Milestone VMS the alarm will still remain open on the Honeywell Galaxy system Solution overview The depth of the layout in the XProtect Management Client Application is minimized to 3 Honeywell Galaxy Dimension Panel X Groups Zones Outputs The delivery is a plug in that will run in the XProtect Event Server and also have a configuration part that runs in the XProtect Management Client Application All communication between the XProtect system and the Honeywell Galaxy panel will go through the Event Server Prerequisites e The Honeywell Galaxy Dimension panel must be equipped with an Ethernet interface Serial cable connections are not supported e The Honeywell Galaxy Dimension panel must be setup to use English Installation The installation package consists of two files EventLinkForHoneywellGalaxyInstaller x86 en US msi 32 bit installer for 32 bit operating systems EventLinkForHoneywellGalaxyInstaller x64 en US msi 64 bit installer for 64 bit operating systems Run the appropriate installer based on the operating system The plug in must be installed on the computer where the XProtect Event Server is running and on all computers running the XProtect Management Client After the
15. er Related cameras Related map Initial alarm owner Initial alarm priority Initial alarm category Events triggered by alam Figure 16 The Alarm Definition dialog in the XProtect Management Client Please note that the Sources should match with the setup on the Honeywell Galaxy Panel in this case Zone 1004 has been selected as source The Triggering event in this case Burglary Intruder zone alarm should also match with the function defined on the zone Activating the zone configured in step one on the Honeywell Galaxy Panel will now generate an event in the VMS system Troubleshooting Guide The panel will not connect to the Honeywell Galaxy panel The Sia Control SIA IP Address must match the computer running XProtect Event Server The Module Config IP Address must match the IP Address specified in the Milestone Plug in In the Milestone Plug in the Port Number must be set to 10005 The encryption MUST be disabled on the Honeywell Galaxy Panel The Honeywell Galaxy panel MUST configured for English language KeyPad 51 17 3 1 The firewall must be off or must be open for communication on the ports e g 19919 10002 and 10005 The Honeywell Galaxy panel must be on the same subnet as the computer running the Milestone XProtect Event Server The License is exceed No event are received The Alarm Reporting must be set to SIA Level 4 Protocol TC
16. ess Furthermore encryption on the Honeywell Galaxy Dimension system is not supported Panel Details In the Groups Zones and Outputs tabs enable the groups zones and outputs that should be subscribed allowing the plug in to control a group zone or output Only subscribed Groups Zones and Outputs will be available for Milestone MAP functionalities z M Du O a Z 1002 A3 1003 ELCHE 3 1004 A5 1005 A F 106 m Z e a e F las 3 g a DL vj D mn 7 1002 EI jg 1012 F 00 B3 1013 1004 B4 1014 B5 1015 1911 B6 E hne Fi qwe e Fi em 10 Cj 18 O ms C 104 Figure 7 Dialog for configure subscription of individuel groups zones outputs Group A1 A4 and B1 Zone 1001 1004 and 1011 Output 1001 and 1011 are subscripted and can be shown on the MAP After the configuration of General Settings and Panel Details is complete remember to save MIP security Users that are part of the administrators group will always have access to the panels groups zones and output in Milestone MAP Other users must be given access using MIP security Milestone MIP security is configured using the XProtect Management Client LI c eng Analytics Events Generic Events Ge Security 5 Roles System Dashboard Q System Monitor Current Tasks I Configuration Reports R Server Logs Security settings for System Log Z Enable Audit Log 7 Disable E
17. installation has completed restart the XProtect Event Server and any open XProtect Management Client License These licenses are obtained by updating the XProtect VMS SLC with MIP components EventLinkForHoneywellGalaxy BaseLicense and EventLinkForHoneywellGalaxy PanelLicense When the update is acquired the XProtect VMS must be reactivated online or offline Event Link for Honeywell Galaxy requires two license components A EventLinkForHoneywellGalaxy Base License a base license for using the plug in Initially a trial period of 30 days is granted A EventLinkForHoneywellGalaxy License a license specifying the number of panels to work with Two additional panels may be used for a period of 30 days NB When activating or loading a license with XProtect Enterprise VMS Save and Apply configuration must be selected in order to notify the entire system of the updated license This is selected from either the File menu or the toolbar alternatively when closing the Management Application set Save and Apply configuration as exit action d MIP Plug ins MIP Plugin Version Developed by License Name License Mode Information Analytics Events 3 0 1177 0 Milestone Systems A S Figur 1 A plug in supporting 5 panels Configuration Honeywell Configuration Configure the Panel using the Key Pad In order to use the plug in a number of settings must be configurated on the Honeywell Galaxy Dimension Panel The configuration can be done
18. out office addresses phone and fax numbers visit www milestonesys com m e The Open Platform Company
19. tion General tab S V6 Application File Edit View Connect Panel Communications Logs Help Hb Pel eii SE SS E RA Via an a 4 General Remote Access Reporting Triggers User Codes System Users Module Config Comm Fail Zones _ IP Address 10 100 74 220 Number Of Attempts 3 Zones Gateway P Address 10 100 1 1 Assemble Zones Line fail Network Mask 255 255 0 0 Network Available Oupus dl RIO Outputs eue deiere Signal Primary Keypad Outputs PE Ew Schedule Output 7 FI Aam M Header Outputs Hours Alam Report F Alam Mon E UNES aj Minutes 0 Remote Access 7 SIA Control LI Interval 0 hours Group Backup Module of X Group Parameters Group Communications Heartbeat SIA Control Links aj Hours 0 SIA IP Address 10 100 0 81 Links Minutes 30 Communications Internal Telecomms External Telacomms ISDN Ethernet Internal RS232 Figure 3 The General Tab in the Honeywell RSS V6 application In the General Tab configure the following Module Config block IP Address must matches the IP address of the computer running the Milestone XProtect Event Server Gateway IP address Network mask Site Name Sia Control block e SIA IP address must match P address of the Milestone XProtect Event Server hosting the Event Link for Honeywell Galaxy plug in Ethernet Reporting tab File Edit View Connect Panel Communications HO O S6li2alS BNE SSE
20. tus Details Figur 12 The context menu for a Group or Zone The right click menu for outputs is very similar but has activate deactivate instead of enable disable Please note that all icons on map will show the known status of the Honeywell Galaxy Panel If the icons are grayed out the object in question will be deactivated or disabled Enabling groups directly on the Honeywell Galaxy Panel will also be reflected by the map icon as illustrated here Disabled group Figure 13 A disabled GroupEnabled group Figure 14 An enabled Group Panels Panels can be Enabled or Disabled Disabling a panel will stop any Milestone control of Groups Zones Output and prevent Milestone alarms from being created originating from the Honeywell Galaxy Panel The events will still perform normally on the Honeywell Galaxy Panel Groups A group is a collection of Zones and Outputs There can be up to 32 groups on the Panel The Groups are named A1 A8 B1 B8 D1 D8 Groups can be Enabled or Disabled Disabling a group will unset the group on the Honeywell Galaxy Panel unsetting a group will cause most Honeywell galaxy alarms to be disabled Enabling a group will move the group to Set state on the Honeywell Galaxy Panel thereby resuming normal behavior Please note that in some cases it s not possible to Set a group i e if there are open alarms tampers or similar Should that be the case these matters must be resolved on the Honeywell Galaxy
21. ualized Startup the Smart Client go to Alarm Manager and configure a new map using the Setup m Milestone XProtect Smart Client 30 08 2013 11 36 24 Lead Live Playback Sequence Explorer System Monitor se gt XProtect lt Setup gt gt gt gt B lt S C lt S Enter fitter V Show navigation tree L 5 m Panel 220 Panel 222 e do XZ Event Link for Honeywe e 100 Max rows to fetch 4 t Panel 222 E mat Data Source Alarm ii Q o x GE 3 A 1002 em x z aiin X OL 8 T D 1 G wwe TL 71g La C dh Mil BG 5 LI 1x Mig p H 1 Alarms Reports D Quick Filters E Time PriorityLevel State Level State Name Message Source Y New 0 Y In progress 0 Y On hold 0 Y Closed 20 Servers d DKWS PS 03 Figure 11 Alarm Manager dialogue in the Milestone XProtect Smart Client Simply drag the objects of interest to the MAP layout When done click setup again and the Honeywell Galaxy integration is now ready for use The Panel s Group s and Zone s can now be controlled by the right click menu this is the right click menu for items of type panel group or zone v Acknowledge Alarms Q Disable Alarms gt 9 Ignore Status r Center Map Here Zoom In 098 Zoom Out Zoom to Standard Size Home Sta
22. utf 8 gt configuration configSections configSections lt appSettings gt add keyz TcpServerPort value 19919 gt add key HoneyerllGalaxyEventServerPort value 10002 add key LogLevel value 2 gt lt appSettings gt lt configuration gt TcpServerPort Specifies the port used by the plug in for communication between the XProtect Management Client plug in and the Event Server plug in Default value 19919 HoneyerllGalaxyEventServerPort Specifies the port number used by the TcpServer receiving event from the Honeywell Galaxy panels If for some reason it is not possible to use the default port number of 10002 the number can be changed in the configuration file If this settings is changed the port number will also have to be changed in the Honeywell Galaxy configuration see Configure the Panel using the Key Pad or Configure the Panel using the RSS application LogLevel Specifies a level of log messages to output to the configuration file Default log level is 2 Log level can be increased to either 3 or 4 The higher the log level is set the more detailed information will be written to the log Changes made to the configuration file requires the plug in hosting application Milestone XProtect Event Server Milestone XProtect Management Client or Milestone XProtect Management Application to be restarted before they will take affect Milestone Systems offices are located across the world For details ab
23. vent Log V Manage V Read EJ Rule Log DO Alarms E de MIP Plug ins H D U Servers Ig Matrix 9 Alarms d mP Figur 8 Setting full rights for a panel on Corporate Not having Manage and Read means that the panel will not be shown in the MAP Element Selector Not having Enable will make it impossible to enable the panel and not having Disable will stop disabling ability Groups and zones have similar settings thus allowing a more fine grained control Outputs have Activate Deactivate instead of Enable Disable Operation Setting up Milestone MAP In order for event alarms to be monitored in the Milestone Alarm Manager the Honeywell Galaxy events must be mapped to a Milestone Alarm and a source Panel Group Zone The mapping is done in the Alarms Alarm Definitions inside the XProtect Management Client CH 3 Alarms Alarm Definitions Alarm Data Settings f Sound Settings f MIP Plun ins Figur 9 Alarm Definitions entry in the XProtect Management Client Select the Honeywell Galaxy in the Triggering event dropdown box and choose an event for the dropdown Depending on the selected event choose one or more sources The sources could either be specific panels groups zones and or all panels groups zones The source must match the event type so to trigger a zone alarm the source must either be a specific zone e g 1001 or All Zones The source for LID and AUX Tampers should
24. y Plug in Edit View Connect Panel DA Danish Denmark Communications Logs Help Missa o E SS EL ERES EIU 1 A Navigation Window ax rr C General Remote Access Reporting Triggers User Codes System Users Zones f Alarm Monitoring Trigger Alarm Reporting Trigger Zones V PA DURESS V PA DURESS Assemble Zones Wi INTRUDER E INTRUDER 4 WI 24 HOURS WI 24 HOURS E V SECURITY V SECURITY RIO Outputs V CUSTOM ZONES CUSTOM ZONES Keypad Outputs V FIRE V FIRE d Schedule Output V SET FAULT TEST V SET FAULT TEST Header Outputs Ei OMIT Z OMIT NI TAMPER V TAMPER Gous V SETTING V SETTING Group Moda V RESET CANCEL V RESET CANCEL Group Parameters V MODULE COMMS V MODULE COMMS Group Communia V ELEC STATUS V ELEC STATUS i V MENU ACCESS V MENU ACCESS Sf v TROUBLE TIMERS v TROUBLE TIMERS Links 7 LOG ZONE V LOG ZONE WE d V MAX TAG V MAX TAG Communications al V ZONE RESTORAL V ZONE RESTORAL Internal Telecomms V SUPERVISION V SUPERVISION External Telecomms v FAULT V FAULT ISDN Ethernet Tntarnal m z Acc Name Milestone Acc Num Panel Type Galaxy 520 Panel Version 6 50 Comm Mediun Figure 5 The Ethernet Triggers tab in the Honeywell RSS v6 application