Home

USER MANUAL - Radiant floor heating systems by Elektra and Ideal

image

Contents

1. 57558 09 03 18 11 03 13 58 Side 1 AR BJ Lagemummer 57558 09 03 USER MANUAL Type UCCG UCDG Installation Please note that although fairly simple the installation and connection of this line voltage thermostat and the entire floor radiant heating warming system should be performed and checked by the qualified professional if required by your national or local building and electrical codes and ordinances Do not install it unless you are completely familiar and competent with house wiring If improperly handled there can be a risk of 120 or 240 V electric shock hazard which may cause serious injury or death CAUTION Use only with electric radiant floor heating Begin by turning off power to the heating circuit at the main service panel Disconnect power supply before making wiring connections to prevent electrical shock or equipment damage Do NOT connect to voltage different from device rating This thermostat allows for either 117 120 VAC OR 230 240 VAC power supply Which one to choose depends on what voltage your floor heating mats are Never mix 230 240VAC and 117 120VAC components of any electrical system unless they are ALL rated for both voltages and RADIANT HEATING MATS NEVER ARE Special service CO ALR solderless connectors must be used when connecting with aluminum conductors otherwise a fire hazard can result This is NOT a typical low voltage thermostat although designed and made with every effort to be sa
2. J Version du logiciel touche OK VY pour quitter Temperature r elle du capteur S quence en quatre v nement La s quence d v nements en cours clignote les jours 1 5 d abord puis les jours 6 et 7 Pour la modifier appuyez sur la touche de d filement vers le haut UP A jusqu ce que les jours 1 6 clignotent puis le jour 7 ou jusqu ce que tous les sept jours clignotent S lectionnez la s quence d sir e en appuyant sur la touche OK Vv 5 2 4 v nements en 5 jours 2 v nements en 2 jours 6 1 4 v nements en 6 jours 2 v nements en 1 jour 7 0 4 v nements en 7 jours Maximum et minimum permis de la plage de temp rature On peut limiter la plage de temp rature r glable de 40 C 104 F afin de pr venir le r glage d une temp rature trop lev e ou trop basse Par exemple la temp rature d un rev tement de plancher de bois ne devrait pas d passer 80 F La limite de temp rature basse sert aux endroits o la temp rature d un plancher ne doit pas tomber sous la temp rature minimum r gl e R glage de la limite de temp rature lev e permise Utilisez les touches de d filement vers le haut UP A ou vers le bas DOWN V pour augmenter ou r duire la temp rature puis appuyez sur la touche OK V pour confirmer L afficheur montre LoLi Appuyez sur la touche OK V pour continuer R glage de la limite de temp rature basse permise Utilisez les tou
3. electrical codes and ordinances Do not install it unless you are completely familiar and competent with house wiring If improperly handled there can be a risk of 120 or 240 V electric shock hazard which may cause serious injury or death CAUTION Use only with electric radiant floor heating Begin by turning off power to the heating circuit at the main service panel Disconnect power supply before making wiring connections to prevent electrical shock or equipment damage Do NOT connect to voltage different from device rating This thermostat allows for either 117 120 VAC OR 230 240 VAC power supply Which one to choose depends on what voltage your floor heating mats are Never mix 230 240VAC and 117 120VAC components of any electrical system unless they are ALL rated for both voltages and RADIANT HEATING MATS NEVER ARE Special service CO ALR solderless connectors must be used when connecting with aluminum conductors otherwise a fire hazard can result This is NOT a typical low voltage thermostat although designed and made with every effort to be safe convenient to install and use this is a line voltage thermostat and safety precaution must be taken when working with all electrical devices operating directly with house current If you have more than one heating mat they should be connected to the thermostat as PARALLEL CIRCUITS and NOT SERIES CIRCUITS Thermostat breaks heating circuit on temperature rise Maximum load for this thermostat MUST
4. exceed a maximum of 80 F Low limitation is used where the temperature of the floor is required never to fall below the minimum set temperature Maximum allowed temperature setting Use the UP A or DOWN V button to increase or reduce and OK V button to accept Next is displayed LoLi Press OK V button to continue Minimum allowed temperature setting Use the UP or DOWN button to increase or reduce and OK V button to accept 51598 09708 18 11 03 13 59 Side 4 ay ae You can select either C or F scale and 12 or 24 hour clock as follows Press UP A or DOWN V button to change settings Confirm the required scale with the OK button v button Adaptive function This function enables the thermostat to calculate when it needs to switch ON so that the required temperature is reached at the set time With a start time of 07 00 therefore the thermostat may switch ON as early as 06 00 so that the desired temperature of 77 F is achieved by 07 00 Without this function set the thermostat will start to heat at the time you set Press the DOWN V button to switch between ON and OFF Press OK V button to confirm Press OK V button to end programming and to return to scheduled program Press the pin button for 3 secs and the thermostat returns to factory settings Time day and scale for time 12h 24h and temperature F C read out a
5. select the correct time and press OK button vV Then press the UP A or DOWN V button to select the correct day and press OK V button Press the UP A button to select time and temperature scale and press OK vV button Checking GFCI It is important that the GFCI has been checked for correct installation and function To check the GFCI Testing can only be performed if the thermostat has a heating demand Adjust the set point until the heating symbol SSS appears use the A to increase the heating demand Wait 10 secs to let the thermostat work according to the new set point Press the button TEST The test is conclusive if the red light on the thermostat lightens and the display signs disappear If this does not occur check the installation Press on RESET button to reset the GFCI The red light should disappear and the display will return to normal appearance Push OK accept button V to cancel the previously set temperature If the test fails check your heating cable and the thermostat The GFCI test should be carried out monthly If the GFCI trips in normal operation without pressing the TEST button there could be a ground fault To check whether it is a ground fault or a nuisance tripping press RESET If this cause the red light to shot off and not comes on again it was a nuisance tripping and the system is functioning If this cannot be done there is a ground fault Check your heating cable
6. NOT exceed 1920Watt 120V or 3840 Watt 240V otherwise a potential fire hazard exists WIRING Power supply Provide disconnect means and the whole line overload protection as required When using an existing wires check the old insulation for cracks nicks or frying and apply certified electrical tape where necessary to achieve adequate insulation or replace the wires in an approved manner Maximum load for particular circuit must not be exceeded In many cases a dedicated circuit or line has to be used Do not use on circuit protected by higher rated over current protection devices Some sustained fault conditions can cause product failure All wiring must comply with applicable codes and ordinances Programmation du produit Ce guide d utilisation contient des renseignements sur les mod les de thermostat avec disjoncteur de fuite a la terre int gr UCCG 9991 avec capteur de plancher 10 ft 3 m UCCG 9999 avec capteur de pi ce UCDG 9999 avec deux capteurs un capteur de pi ce et un capteur de plancher 10 ft 3 m Introduction Le thermostat est du type lectronique action par tout ou rien qui r gule la temp rature au moyen d un capteur NTC plac soit l ext rieur soit l int rieur du thermostat Il est dot d un disjoncteur de fuite la terre GFCI de classe A Le thermostat et le GFCI sont compatibles aux modes d alimentation 120 240 V 50 60 Hz Le thermostat peut activer le syst me de chauffage a des heures pr d termi
7. ches de d filement vers le haut UP A ou vers le bas DOWN A pour augmenter ou r duire la temp rature puis appuyez sur la touche V pour confirmer 51598 09708 18 11 03 14 00 Side 8 prs ae Vous pouvez choisir d afficher la temp rature en degr s Celsius ou Fahrenheit et de diviser le jour en p riodes de 12 ou 24 heures de la fa on suivante Appuyez sur les touches de d filement vers le haut UP A ou vers le bas DOWN V pour modifier les r glages Confirmez l chelle ou la division du jour requise en appuyant sur la touche OK v Fonction adaptative Cette fonction permet au thermostat de calculer quel moment il doit se mettre en circuit pour que la pi ce soit la temp rature requise l heure r gl e Donc si le d but de la p riode de chauffage est r gl e 7 h il se peut que le thermostat se mette en circuit aussi t t que 6 h afin que la pi ce soit la temp rature requise de 77 F 7 h Si vous n activez pas cette fonction le thermostat lancera le syst me de chauffage l heure que vous avez r gl e Appuyez sur la touche de d filement vers le bas DOWN V pour commuter entre l activation et la d sactivation de cette fonction Appuyez sur la touche OK Vv pour confirmer Appuyez sur la touche OK V pour mettre fin la programmation et revenir l horaire programm Appuyez sur le bouton miniature pendant trois secondes et le thermostat revi
8. e La plage de temp rature est r glable de 40 C a 104 C Il est galement possible de mettre le chauffage hors circuit pour cet v nement en r duisant la temp rature a 40 F et en appuyant sur la touche V nouveau Heure et temp rature 4 R glages avanc s et lectures Appuyez simultan ment sur les touches de d filement vers le haut UP A et vers le bas DOWN V pendant trois secondes L afficheur montre INFO Appuyez sur la touche de d filement vers le haut UP A jusqu au sous menu recherch S lectionnez le sous menu en appuyant sur la touche OK Vv Surveillance de la consommation d nergie Le thermostat calcule son temps moyen de fonctionnement afin de vous permettre de surveiller la consommation d nergie Vous pouvez prendre les lectures suivantes du thermostat Temps total en circuit en pourcentage durant les 2 30 ou 365 derniers jours Calcul des co ts d exploitation par jour temps en circuit 100 x kW x co t du kWh x 24 h par jour Exemple Lecture 30 au cours des 365 derniers jours Puissance du syst me de chauffage 1 2 KW demandez l installateur Co t de l lectricit 0 20 US kWh Calcul 30 x 1 2 kW x 0 20 US kWh x 24 h 1 73 US par jour an Appuyez sur les touches de d filement vers le haut UP A ou 30 jours e vers le bas DOWN V pour afficher les diff rentes lectures 365 jours agg Vous ne pouvez effectuer aucun changement ici Appuyez sur la
9. e de limite pour emp cher que la temp rature du plancher ne soit trop lev e ou trop faible Le thermostat dispose d un bouton miniature identifi d un R qui vous permet de le r initialiser aux r glages de l usine Ces r glages sont num r s la fin de ce guide Il y a aussi de l espace afin que vous puissiez prendre en note votre propre horaire hebdomadaire 1 D but Touches Symboles de l affichage D N oe 2 Bouton miniature pour le Chauffage en circuit r glage de l horloge O O ad E Pourcentage de a Affichage temps en circuit OJ Microline F P Reset A s Remise aux r glages Symboles des quatre effectu s en usine v nements G T veil Ajustement vers le bas MEME E gds Nuit H OK acceptation Hors de la maison I Ch a maison Ajustement vers le haut A B C J K L M R initialisation Voyant rouge V rification Fonction Mode Heure et Num ro du disjoncteur indicateur de du disjoncteur d horloge Manual temp rature de jour de fuite la mise la masse de fuite la terre d fectueuse terre CN 51598 09708 18711703 13 59 Side 6 ay ar Activation du thermostat la premi re mise en alimentation l heure et le jour clignoteront et il faudra les r gler Apr s avoir r gl l heure et la date il est possible de s lectionner le mode d affichage des heures 12 ou 24 heures et l chelle de temp rature C ou F Si vous devez ult rieurement r gler l
10. endra aux r glages effectu s en usine Les param tres d heure de jour d affichage des heures 12 ou 24 heures et d chelle de temp rature F ou C sont aussi r initialis s et doivent tre r gl s de nouveau comme c est d crit la section Activation du thermostat R glage en usine Heure et temp rature des quatre v nements i 08 00 Avec capteur de plancher 77F 250C 68 F 20 C ee 68 F 20 C 59 F 15 C SS 81 F 27 C 72 F 22 C S Capteur int gr EE quatre v nements oe Limites sup rieure et inf reure de 131 F 41 F temp rature chelle 24H F Commande ma En circuit adaptative 6 Codes de d rangement Plage de t mperature 5 40 C 40 to 104 F EO D fectuosit interne remplacez le thermostat Plage de t mperature ambiante E1 Capteur interne court circuit ou d connect remplacez le thermostat Thermostat de 0 40 C 32 104 F E2 Capteur externe court circuit ou d connect GFCO ER sani 35 65 C 31 149 F 7 Fiche technique ELEKTRA TRADING SERVICE US CAN Source d alimentation 120 240 V c a 50 60 Hz ul Marynarska 14 Ideal Heating LLC Charge 16A maximum charge r sistive 02 674 Warszawa service ideal heating com Puissance 2 6 2 e ee eee eee es 1 920 W 120 V c a Poland 3 840 W 240 V c a Tel 48 22 843 32 82 GFG PR ewe kets Classe A e mail office e
11. ent Dans le cas contraire v rifiez l installation Appuyez sur la touche RESET pour r initialiser le disjoncteur de fuite la terre Le voyant rouge devrait s teindre et l affichage revenir la normale Appuyez sur la touche d acceptation Vv pour annuler le r glage de temp rature pr c dent Si le test choue v rifiez le c ble chauffant et le thermostat Le test du disjoncteur de fuite la terre devrait tre effectu mensuellement Si le disjoncteur se d clenche en mode de fonctionnement normal sans qu il soit n cessaire d appuyer sur la touche TEST cela pourrait indiquer la pr sence d une mise la masse d fectueuse Pour v rifier s il s agit d une mise la masse d fectueuse ou d un d clenchement intempestif appuyez sur la touche de r initialisation RESET Si le voyant rouge s teint et qu il ne se rallume pas il s agissait d un d clenchement intempestif et le syst me fonctionne correctement Dans le cas contraire il y a effectivement une mise la masse d fectueuse V rifiez le c ble chauffant le c ble du capteur et le thermostat puis remplacez la pi ce d fectueuse 2 Usage quotidien du thermostat p Mode d horaire divis en quatre v nements Le jour type a t divis en quatre v nements Lorsque le thermostat est en mode de quatre v nements il r gle automatiquement la temp rature de la pi ce requise l heure tablie Le thermostat de s rie commande quatre v nements par jour sur u
12. fe convenient to install and use this is a line voltage thermostat and safety precaution must be taken when working with all electrical devices operating directly with house current If you have more than one heating mat they should be connected to the thermostat as PARALLEL CIRCUITS and NOT SERIES CIRCUITS Thermostat breaks heating circuit on temperature rise Maximum load for this thermostat MUST NOT exceed 1920Watt 120V or 3840 Watt 240V otherwise a potential fire hazard exists WIRING Power supply Provide disconnect means and the whole line overload protection as required When using an existing wires check the old insulation for cracks nicks or frying and apply certified electrical tape where necessary to achieve adequate insulation or replace the wires in an approved manner Maximum load for particular circuit must not be exceeded In many cases a dedicated circuit or line has to be used Do not use on circuit protected by higher rated over current protection devices Some sustained fault conditions can cause product failure All wiring must comply with applicable codes and ordinances Product program This user manual covers following thermostats with built in GFCI UCCG 9991 Incl floor sensor 10 ft 8m UCCG 9999 With built in room sensor UCDG 9999 With 2 sensors built in room sensor and incl floor sensor 10 ft 8m Introduction The thermostat is an electronic on off thermostat for control of temperature by means of an NTC senso
13. he thermostat controls the temperature within the room and use the externally temperature sensor as limit sensor avoiding too high or too low temperatures in the floor construction The thermostat has a pin button marked R allowing you to reset the thermostat to factory settings These are listed at the end of this manual with space for you to record your own weekly schedule 1 Getting started Buttons Display symbols D N 2 Pin button Heating on amp adjust of clock O fr E Monitoring of mn Display switch on time F P Reset to factory 4 event setting symbol G Wake Adjustment down CCE ET q Night H OK accept U Out I Cha Home Adjustment up A B C J K L M Reset of GFCI Red light Test of GFCI Clock Manual Time and Day indicating function mode temperature number ground fault Type UCCG UCDG 51598 09708 18711703 13558 Side 2 ay ar Setting the thermostat into operation First time power is connected the clock and day will be flashing and must be set After setting of time and day selection of time scale 12 h or 24 h and temperature scale C or F can be selected If you need to adjust the time of the thermostat at a later date insert a pin into the hole for setting of time and day Adjustment must be made for summer and winter time Setting of time and temperature scale can also be done under advanced settings and read out see 4 Press the UP A or DOWN V buttons to
14. heure du thermostat ins rez un objet pointu dans l orifice pour r gler l heure et le jour de nouveau II faut aussi ajuster le thermostat en fonction de l heure d hiver et de l heure d t On peut galement r gler le mode d affichage des heures et l chelle de temp rature dans les r glages avanc s voir la section 4 Appuyez sur les touches de d filement vers le haut UP A ou vers le bas DOWN V pour r gler l heure puis appuyez sur la touche OK V Appuyez sur les touches de d filement vers le haut UP A ou vers le bas DOWN V pour r gler le jour puis appuyez sur la touche OK V Appuyez sur la touche de d filement vers le haut UP A pour r gler le mode d affichage des heures et l chelle de temp rature puis appuyez sur la touche OK V V rification du disjoncteur de fuite la terre GFCl Il est important de v rifier l installation et le fonctionnement du disjoncteur de fuite la terre Test du disjoncteur Pour v rifier le fonctionnement du disjoncteur il faut qu il y ait une demande de chauffage au thermostat R glez la demande de chauffage au thermostat jusqu ce que le symbole SSS s affiche Servez vous de la touche A pour augmenter la demande Patientez dix secondes pour laisser le thermostat s adapter la nouvelle demande puis appuyez sur la touche TEST Le test est concluant si le Voyant rouge du thermostat s allume et que les signes sur l affichage disparaiss
15. lektra pl seuil e d clenchement r gl a 5 mA www elektra pl CT
16. n es pour des jours diff rents de la semaine Il est possible de r gler quatre p riodes appel es v nements des temp ratures diff rentes chaque jour Un horaire par d faut qui convient la plupart des installations a t programm en usine A moins que vous ne modifiiez ces r glages le thermostat fonctionnera selon ce programme par d faut Si vous r glez le chauffage une temp rature plus basse lorsque la pi ce est inoccup e vous couperez les co ts d nergie sans r duire le confort Le thermostat est muni d une fonction adaptative qui modifie automatiquement l heure de d but de la p riode de chauffage afin que la temp rature d sir e soit atteinte l heure que vous avez r gl e Apr s cinq p jours la fonction adaptative sait quand activer le syst me de chauffage Le mod le de thermostat UCCG 9991 est muni d un capteur de temp rature externe que l on place normalement dans le plancher De cette fa on le thermostat contr le la temp rature du plancher et non celle de la pi ce Le mod le de thermostat UCCG 9999 est dot d un capteur de temp rature int gr Dans cette configuration le thermostat contr le la temp rature de la pi ce Le mod le de thermostat UCDG 9999 est dot d un capteur de temp rature int gr et d un capteur de temp rature externe Dans cette configuration le thermostat contr le la temp rature l int rieur de la pi ce et utilise le capteur de temp rature externe comme une sond
17. ne p riode de cinq jours et deux v nements par jour sur une p riode de deux jours Voir en page 3 pour la programmation Mode d horaire divis en ae Le symbole de l horloge et un des quatre symboles d v nement amp amp 1 s afficheront quatre v nements Voir en page 3 pour la programmation Mode confort Fonctionnement prioritaire temporaire Pour contourner temporairement le r glage de temp rature du programme en quatre v nements appuyez sur les touches de d filement vers le haut UP A ou vers le bas s AV x 9s Le DOWN Y pour afficher la temp rature et appuyez sur les touches de nouveau pour augmenter ou r duire la temp rature L affichage clignotera pendant cinq secondes puis reviendra au mode d affichage de l heure Le r glage de temp rature prioritaire subsistera jusqu l activation du prochain v nement automatique programm Annulation du mode confort Pour annuler l tat prioritaire appuyez sur la touche OK V deux reprises Mode manuel Fonctionnement prioritaire permanent Durant les cong s par exemple il est possible de contourner l horaire du programme en quatre v nements Appuyez sur la touche OK VY puis sur les touches de d filement vers le haut UP A ou vers le bas DOWN V pour r gler la temp rature d sir e L appareil maintiendra la temp rature de la pi ce ce niveau de fa on permanente Annulation du mode manuel Pour annuler l tat
18. prioritaire permanent appuyez sur la touche OK V une fois et l appareil reprendra la programmation automatique 51598 09708 18 11 03 14 00 Side 7 di KE V Heure et temp rature des quatre v nements Appuyez sur la touche OK V pendant trois secondes pour commencer la programmation Pour chaque v nement il faut r gler l heure de d but de Jours 1 5 la p riode de chauffage et la temp rature Vous pourriez par exemple d sirer que le chauffage Gr Heure et temp rature commence 7 h dans la matin e et que la temp rature s l ve 77 F Appuyez sur la touche OK V pendant trois secondes pour afficher l heure de d but de la p riode de chauffage R glez l heure 7 h l aide des touches de d filement vers le haut UP A ou vers le bas DOWN V Appuyez sur la touche OK VY pour confirmer La temp rature s affiche R glez la 77 F l aide des En p 24 Heure et temp rature touches de d filement vers le haut UP A ou vers le bas 7 DOWN V Appuyez sur la touche OK Vv pour confirmer R p tez ces tapes pour le deuxi me v nement Ch Heure et temp rature Heure et temp rature Ces r glages sont valides pour les jours 1 5 qui sont affich s R p tez les tapes ci dessus pour programmer les jours 6 et 7 Il n y a que deux v nements pour les jours 6 et 7 qui sont habituellement le samedi et le dimanche Heure et temp ratur
19. r either placed externally or internally in the thermostat The thermostat has integrated a Ground Fault Circuit Interrupter GFCI Class A The thermostat and the GFCI is a dual model suitable for 120 240 V 50 60 Hz supply p The thermostat is capable of switching on your heating system at pre determined times on different days of the week It is possible to set 4 periods called events each day with different temperatures From factory a default schedule is programmed suitable for most installations Unless you change these settings the thermostat will operate to this default program Working with lower temperatures during times that the room is unoccupied will lower your energy costs without reducing the comfort The thermostat has an adaptive function that automatically changes the start time of a heating period so that the desired temperature is reached at the time that you set After 5 days the adaptive function has learned when the heating must be switched on The thermostat type UCCG 9991 has an external temperature sensor that is normally placed in the floor construction In this configuration the thermostat controls the temperature of the floor and not the temperature within the room The thermostat type UCCG 9999 has a built in temperature sensor In this configuration the thermostat controls the temperature of the room The thermostat type UCDG 9999 has a built in temperature sensor and an externally temperature sensor In this configuration t
20. re also reset and must be set according to Setting the thermostat into operation pren faune perse ferme era fors orare fee Frat us ssr 20c 59 F 15 C 08 00 ee srr 2rc 72 F 22 C 68 F 20 C 59 F 15 C Hi Low temp 131 F 41 F Adaptive control 6 Failure codes EO Internal failure replace thermostat E1 Built in sensor short circuit or disconnected replace thermostat E2 External sensor short circuit or disconnected 7 Technical data SUDDIY sis oe bo eae ee wen 120 240 Vac 50 60 Hz L d sok xs eewsiaets 16A maximum resistive load POW Lois sn da de Gaay de 1 920 W at 120 Vac ELEKTRA TRADING 3 840 W at 240 Vac ul Marynarska 14 GFCO 1 14 ni Class 5 mA trip level 02 674 Warszawa Temperature range 5 to 40 C 40 to 104 F Poland Amb Temperature range Tel 48 22 843 32 82 Thermostat 0 to 40 C 32 to 104 F e mail office elektra pl GFCO siiisaidenses 35 to 65 C 31 to 149 F www elektra pl SERVICE US CAN Ideal Heating LLC service ideal heating com 575589 09703 18711703 13 59 Side 5 di KL Fran ais Installation Please note that although fairly simple the installation and connection of this line voltage thermostat and the entire floor radiant heating warming system should be performed and checked by the qualified professional if required by your national or local building and
21. the sensor cable and the thermostat Exchange the defective part 2 Daily use of the thermostat 4 event clock mode The day has been split into 4 events describing a typical day When the thermostat is in 4 event mode it will automatically adjust the temperature according to the required temperature to the required time As standard the thermostat has 5 days with 4 events and 2 days with 2 events Programming see 3 4 event clock mode The clock function symbol and one of the 4 event symbols amp fm q will be indicated Programming see 3 Comfort mode Temporary override To temporarily override the temperature in the 4 event schedule program press the UP or DOWN V button mz AV X once to show the temperature and press again to increase or decrease the temperature The display will flash for 5 seconds and will then revert to the time The override will operate until the next programmed event when the unit will resume the automatic program Cancel comfort mode To cancel the override state press the OK V button twice Manual mode Permanent override During holidays the scheduled 4 event program can be overridden Press the OK V button and then the UP A Sd V AV x 5 secs or DOWN V button until the override temperature is set The unit will now operate to this temperature permanently Cancel manual mode To cancel the permanent override state press the OK V button once and
22. the unit will resume automatic function 51598 09708 18 1170 13 59 ide 3 di KE 3 Programming 4 event time and temperature For each event the start time and required temperature must be Day 1 5 a set For example in the morning you wish the heating to start at Time and temperature 07 00 and the temperature to rise to 77 F Press OK V button for 3 seconds and the start time is displayed Change this to 07 00 with the UP or DOWN V button Press OK V to confirm The temperature is now displayed Change this to 77 F with the UP A or DOWN V button Press OK V button for 3 secs to begin programming Ch Time and temperature li Time and temperature Press OK V button to confirm This action can now be repeated for the second event These settings will be valid with days 1 5 showing on the L Time and temperature display To program the days 6 and 7 repeat the above Days 6 l and 7 are usually Saturday and Sunday and only have two events The temperature can be set within the range of 40 to 104 F It Time and temperature is also possible to select the heating OFF at that event by i ji reducing the setting to 40 F and then pressing the V once more Time and temperature 4 Advanced settings and read out is Z Press both UP and DOWN V buttons together for 3 seconds INFO is displayed Press UP bu
23. tton until you reach the desired sub menu Select the sub menu with the OK V button Monitoring of energy consumption The thermostat calculates average time it has been switched on allowing you to monitor your energy consumption In the thermostat you can read out Total switch on time in percentage in the latest 2 days 30 days or 365 days Calculation of operational costs per day switch on time 100 x kW x kWh price x 24 h per day Example Read out 30 in the latest 365 days Size of heating system 1 2 kW ask the installer Cost of power 0 2 USD kWh Calculation 30 100 x 1 2 KW x 0 2 USD kWh x 24 h 1 7 USDper day 2 days 30 days Press UP or DOWN V button to show the different readouts 365 days No changes can be made here Use the OK Vv button to end Software version Actual sensor temperature V 4 event sequence The present event sequence flashes Days 1 5 followed by days 6 7 To change press the UP 4 button until you Pr have days 1 6 and then day 7 flashing or all 7 days are flashing Select the required sequence with the OK V button 5 2 4 events in 5 days 2 events in 2 days 4 events in 6 days 2 events in 1 day 4 events in 7 days Max and min allowed temperature range The temperature setting range of 40 to 104 F can be limited to prevent a too high or too low temperature being selected For example a wood floor covering should not be allowed to

Download Pdf Manuals

image

Related Search

Related Contents

Gitzo GT3530LSV User's Manual  SRMC4 CN1105L/H002 0 2015年07月  poudre de renovation verso.ai  User Manual User Manual  Handleiding  USER MANUAL EdU Click FC  

Copyright © All rights reserved.
Failed to retrieve file