Home

KI6501 CWDM Power Meter User Manual

image

Contents

1. Use A V to scroll between available display pages See picture below for SCAN Mode User Interface User Manual KI6501 Optical CWDM Power Meter Revision 3 Page 12 of 27 INTERNATIONAL Fiber Optic Test Equipment Manufacturer KI6501 Opti cal CWDM Power Meter 12 01 01 12 00 CWDM Scan 1270 nm dBm 1290 nm dBm 1310 nm dBm 1330 nm dBm 1350 nm dBm 1370 nm dBm 1390 nm dBm 1410 nm dBm 1430 nm dBm 6 6 Measurement unit dB dBm selection Press dB dBm to toggle between the measurements units of dB and dBm in PM Power Meter Modes The displayed power will be become 0 00 dB when dB dBm is pressed see figure below 12 01 O1 62212 00 PM Auto 1270 mm 0 00 User Manual KI6501 Optical CWDM Power Meter Revision 3 Page 13 of 27 INTERNATIONAL Fiber Optic Test Equipment Manufacturer KI6501 Optical CWDM Power Meter 6 7 Graphical Display Mode Press Graph to display the wavelengths power values scanned at the optical input in graphical format see picture below for an example 12 01 01 G12 00 Press Graph again will switch the display to the multiple wavelength format shown in example of section 6 5 6 8 Saving Scanned Data in Instrument s Memory In SCAN Mode press Save to save the scanned optical input data into memory see below user interface Press ENTER to continue with the data saving process or press ESC to quit without saving A maximum of 1000 test data record f
2. 12 00 Menu SCAN Set 0 00 dBm dBm System Info Scan Display User Manual KI6501 Optical CWDM Power Meter Revision 3 Page 19 of 27 INTERNATIONAL Fiber Optic Test Equipment Manufacturer KI6501 Opti cal CWDM Power Meter 6 10 3 Auto Power Off Use this option to program the time elapsed before the instrument is automatically switched off after the last key press See picture below for this option s user interface Press ENTER use numerical keys to input a time between 5 600 minutes and press ENTER again to save setting or press ESC to return to Menu Option list without saving 12 01 01 G12 00 Menu 10 Minute Minute Data Format System Info Scan Display 6 10 4 Time Set option Use this option to set the date and time of the instrument See picture below for this option s user interface Use the numerical keys to enter the date and time and press ENTER to save setting or press ESC to return to Menu Option list without saving User Manual KI6501 Optical CWDM Power Meter Revision 3 Page 20 of 27 GFISHER DITAA EER Fiber Optic Test Equipment Manufact KI6501 Optical CWDM Power Meter 12 01 01 B 12 00 Menu LZ NANNA bt Ne tU Data Format System Info Scan Display 6 10 5 Data Delete option Use this option to delete selected test data records from instrument s internal memory See picture below for this option s user interface Use A V to highlight the tes
3. 16501 Optical CWDM Power Meter Revision 3 Page 4 of 27 INTERNATIONAL Fiber Optic Test Equipment Manufacturer KI6501 Optical CWDM Power Meter 3 Specifications Parameters Value Technical Calibrated A nm 1270 1290 1310 1330 1350 1370 1390 1410 1430 1450 1470 1490 1510 1530 1550 1570 90 1610 KE Channel spacing nm Measurement speed sec Measurement range dBm Measurement accuracy dB Damage level dBm Fiber type General Optical connector interface SC PC Display 2 8 Colour LCD with backlight 15 Number of channels 18 0 Display unit Display resolution Memory PC interface Battery type Battery life Auto off function Charging time Flat battery performance Unit works when charging a flat battery External power charging Via USB port Operate Storage Relative pr humidity 20 55 C 10 50 C 90 0 40 C Size Weight 155 x 78 x 34 mm 6 10 x 3 07 x 1 34 0 35 kg 0 77 Ib Note 1 At 20dBm 10 50 C 4nm from centre of pass band 9 5 125 fiber User Manual KI6501 Optical CWDM Power Meter Revision 3 Page 5 of 27 INTERNATIONAL Fiber Optic Test Equipment Manufacturer KI6501 Optical CWDM Power Meter 4 Safety Take appropriate eye safe precautions when handling live fibre Avoid condensation The instrument is resistant to normal dust and moisture however it is not waterproof If moisture gets into the instrument remove the batteries and dry it ou
4. 70 O 1290 O 1270 X 1290 X 1350 O 1370 O 1350 X 1370 X 1351 O 1450 O 1351 X 1450 X 1510 O 15300 1510 X 1530 X 15900 16100 1590 x 1610 x O indicates the selected wavelengths X or indicates the unselected wavelengths To select the wavelength s press ENTER on the display below 00 01 016 12 00 SCAN Set All Scan select the wavelength X E e i ES x 1450 X 1470 X 1490 X 1530 X 15500 1570 X 1610 X Use A V to highlight the desired wavelengths from the available 18 wavelengths displayed in 2 pages Press ENTER to toggle ON select or OFF unselect the highlighted wavelength Press ESC to return to the option list of Menu User Manual KI6501 Optical CWDM Power Meter Revision 3 Page 18 of 27 INTERNATIONAL Fiber Optic Test Equipment Manufacturer 6 10 2 Offset option K16501 Optical CWDM Power Meter 12 01 01 B 12 00 Select Lambda 1270 f ete Press ENTER to toggle ON or OFF SW eo ee re ee oe EON Tee In PM Power Meter Modes the displayed power measurements of all wavelengths are offset by the value pre programmed in this option See picture below for this option s user interface Press ENTER use the numerical keys to input the desired offset values between 25 99 25 99 dBm Use A or V to select or sign Press ENTER to save the saving or press ESC to return to option list of Menu without saving 12 01 01 amp
5. INTERNATIONAL Fiber Optic Test Equipment Manufacturer KI6501 Optical CWDM Power Meter User Manual KI6501 series Optical CWDM Power Meter Warranty Information in this manual is given in good faith for the benefit of the user It cannot be used as the basis for claims against Kingfisher International or its representatives if accidental damage or inconvenience results from use or attempted repair of the equipment This Kingfisher International product is guaranteed against defective components and workmanship for a period of 1 year from the date of delivery unless specifically stated in the original purchase contract or agreement This warranty excludes optical connectors or incorrect use The warranty will be voided if the following instance happens 1 Dismantling the instrument 2 The instrument has been immersed in water or subjected to extreme environmental conditions Liability is limited solely to repair of the equipment User Manual KI6501 Optical CWDM Power Meter Revision 3 Page 1 of 27 INTERNATIONAL Fiber Optic Test Equipment Manufacturer KI6501 Optical CWDM Power Meter CONTENTS 1 SUNN Geek 3 2 Main Instrument Features rr nnnannnnnnnnnnnnnnnnnnnnennnnnnnnnnnnnnennnnnnnnnnnnnnnnnnnn 4 3 OC CICA ONS mrs 5 VNR 6 5 IASTUMENT LAV OE soseri EAE AEAEE REEE E EESE 7 6 Operation iNStructions savassemsrinma bedste 8 6 1 General functions of instrument Keys rrrrrrrrnnnrrrrrrrnnnnnrrvrrnnnnnrenn 8 6 2 Swi
6. Software enables stored test data to be downloaded to PC Applications of KI6501 CWDM Power Meter include the following e Wavelength selective Power Meter for systems with CWDM channel spacing e Quickly determine active channels e Diverse FTTx systems RFOG etc For application support please visit www kingfisherfiber com to see our comprehensive Application Notes written to support instrument users or an updated version of this manual FAQ can be found in the Support section of our website Look at ww kingfisherfiber com to find distributor and service centre details from the Contact Us section Otherwise if you are having difficulties please feel free to contact sales kingfisher com au for application support User Manual KI6501 Optical CWDM Power Meter Revision 3 Page 3 of 27 GFISHER INTERNATIONAL Fiber Optic Test Equipment Manufacturer KI6501 Opti cal CWDM Power Meter 2 Main Instrument Features Compact rugged amp light weight Simple to use Fast measurement speed Scan range of 18 calibrated wavelengths Larger sunlight readable backlit colour display Simultaneous 9 wavelengths loss display Tabular and graphical display modes Internal memory for 1000 test records Test data transfer via USB port Programmable auto shut off e External power charger via mini USB port LED indicator for battery charging status 12 months warranty Low cost User Manual K
7. accumulated on surface of the sensor this will in turn result in measurement inaccuracy 5 Consider leaving test cords connected to the instrument at all times This will prolong the life of the instrument s optical connector User Manual KI6501 Optical CWDM Power Meter Revision 3 Page 27 of 27
8. ile can be saved User Manual KI6501 Optical CWDM Power Meter Revision 3 Page 14 of 27 INTERNATIONAL Fiber Optic Test Equipment Manufacturer KI6501 Optical CWDM Power Meter 12 01 01 B 12 00 2012 08 01 12 00 00 J 1590 nm 1610 nm 6 9 Retrieving Data Save in Instrument Press Recall and the user interface below will be displayed 12 01 01 12 00 Data Store 120101 21 59 34 120201 08 06 15 120301 06 16 05 120601 12 Use A V to highlight the desired file in which data was saved followed by pressing ENTER The data will be retrieved and displayed on LCD as shown in picture below User Manual KI6501 Optical CWDM Power Meter Revision 3 Page 15 of 27 INTERNATIONAL Fiber Optic Test Equipment Manufacturer KI6501 Opti cal CWDM Power Meter 12 01 01 612 00 120601 17 01 00 1270 nm 1290 nm 1310 nm 1330 nm 1350 nm 1370 nm 1390 nm 1410 nm 1430 nm dBm dBm dBm dBm dBm dBm dBm dBm dBm Use A V to scroll between the available displays pages to read all data in the retrieved file Toggle Graph to display the retrieved data in graphical or tabular multiple wavelength format 6 10 Instrument Setup options Press Menu to display the available instrument setup options in the Menu Option List Pictures below show the Menu Option list in 2 display pages Use A V to scroll between available pages and to highlight the desired option Press ENTER to selec
9. ment Manufacturer KI650 1 Opti cal CW D M Power Meter 6 10 8 Scan Display option Use this option to program instrument to display work only with Scan Mode section 6 5 optical input scan result in the following options Display the scanned wavelengths detected with power values only OR Display all the wavelengths selected for scanning See pictures below for the user interface Use A W to toggle between AI and Measured and press ENTER to select the desired display mode Display mode Measured to display wavelengths detected with power values only Display mode All to display all wavelengths selected for scanning 12 01 01 B 12 00 12 01 01 EB 12 00 Menu Menu SCAN Set Data Format Data Format System Info Scan Display Scan Display User Manual KI6501 Optical CWDM Power Meter Revision 3 Page 23 of 27 INTERNATIONAL Fiber Optic Test Equipment Manufacturer KI6501 Optical CWDM Power Meter 6 10 9 PM Scan Mode option This option provides an alternative method to that in section 6 3 of programming PM Modes see section 6 4 to operate in Auto or Manual condition See picture below for the user interface Use A VW to toggle between Auto and Manual Press ENTER to save setting or press ESC to return to option list of Menu without saving 00 01 01 E312 00 Menu 6 10 10 Threshold option Use this option to program the threshold level which is visible when the scan
10. ned data is presented on graphical format Use the numerical keys to enter a new valid threshold value 40dBm 10 dBm and use A YW for or sign selection Press ENTER to save the new threshold setting See pictures below for examples User Manual KI6501 Optical CWDM Power Meter Revision 3 Page 24 of 27 INTERNATIONAL Fiber Optic Test Equipment Manufacturer KI6501 Opti cal CWDM Power Meter 12 01 01 B 12 00 Menu C ANI Minada ENNGNNNUNNNANNEENENGANEDENEGENEGENSASNyy x Previously programmed threshold 00 0Q rtree EE EE EE EE EE ed 30 00 dBm SOU Jegere NERE te a EEE ee gee oP eee eee Pee POPP OPO KEENE EEE EEE NE EEE EEE EET Previously programmed threshold q annan won oc 310 330 350 27 YAN Pieta 6 10 11 Graph Color This option provides choices of displaying graphical test result in different colour format See pictures below for the user interfaces Use A V to toggle between the available selections Single displays peak wavelengths in same color and Multi displays peak wavelengths in different colors and press ENTER to save setting of pres ESC to quit without saving User Manual KI6501 Optical CWDM Power Meter Revision 3 Page 25 of 27 GFISHER INTERNATIONAL Fiber Optic Test Equipment Manufacturer KI650 1 Opti cal CW D M Power Meter 00 01 01 amp 112 00 00 01 01 amp 12 00 7 Charging of In
11. other operation modes to this by pressing PM see picture below for instruments user interface User Manual KI6501 Optical CWDM Power Meter Revision 3 Page 10 of 27 rattle i KI6501 Optical CWDM Power Meter Fiber Optic Test Equipment Manufacture 12 01 01 8 12 00 PM Auto ai 1270 nm 6 49 PM Manual Mode Use this operation mode to manually select and display real time power values of the wavelengths available at the optical input See picture below for user interface of this mode 12 01 01 G12 00 PM METTE ie 1290 nm 11 07 In PM auto Mode press PM once to switch to PM Manual Mode Use A V to select the desired wavelengths for power values displays Press PM again to return the instrument to PM Auto Mode Revision 3 User Manual KI6501 Optical CWDM Power Meter Page 11 of 27 INTERNATIONAL Fiber Optic Test Equipment Manufacturer KI6501 Optical CWDM Power Meter 6 4 CWDM Mode Press CWDM to scan optical input once and display power values in single wavelength display mode See picture below for CWDM user interface 12 01 01 12 00 CWDM 1270 nm 1 00 Use A V to display the power values of other wavelengths scanned at the optical input 6 5 SCAN Mode When SCAN is pressed the wavelengths and their corresponding power values scanned at the optical input will be displayed in multiple wavelength format A max of 9 wavelengths can be displayed simultaneously
12. strument Link the mini USB connector on instrument See section 5 Instrument Layout to a PC s USB port or a USB charger using the provided USB cable The Charging Status LED see section 5 Instrument Layout will light up to indicate the status of charging as described below Red light charging in progress Green light fully charged This battery indicator BS displayed on instrument s LCD indicates that the instrument is being charged Note that when linked to an external power supply the instrument is still operable in the events that the internal battery has been totally discharged the internal battery has been removed User Manual KI6501 Optical CWDM Power Meter Revision 3 Page 26 of 27 INTERNATIONAL Fiber Optic Test Equipment Manufacturer KI6501 Optical CWDM Power Meter 8 Packaging Content Item Description Quantity KI 6501 Optical CWDM Power Meter User manual USB cable USB min USB CD Data Management Software Carry strap 9 Maintenance 1 Keep the sensor s surface in the optical connector clean and free of dust or other contaminant by cleaning them regularly 2 Do not use unclean or nonstandard adapters 3 Change adapter carefully if necessary and keep any spare adapter in dirt dust free environment 4 When the instrument is not in use keep the optical connectors covered with dust caps at all the time Exposing the sensor for a long period of time will allow dust to be
13. t carefully for at least one hour before using it again Storage The equipment can be stored at the specified temperatures and relative humidity Protect the unit from temperature extremes that may cause condensation within it Make sure to switch off the instrument whenever it is not in use Keep the optical connector covered with the dustcover at all time User Manual KI6501 Optical CWDM Power Meter Revision 3 Page 6 of 27 GFISHER INTERNATIONAL Fiber Optic Test Equipment Manufacturer KI6501 Opti cal CWDM Power Meter 5 Instrument Layout Color LCD Display Optical Connector Mini USB connector INTERNATIONAL Charging status LED ALNVEYVM Gi9vAY SI 1V3S l GIOA Ws Instrument keys User Manual KI6501 Optical CWDM Power Meter Revision 3 Page 7 of 27 INTERNATIONAL Fiber Optic Test Equipment Manufacturer KI6501 Optical CWDM Power Meter 6 Operation instructions 6 1 General functions of instrument keys Backlight ON OFF Instrument ON OFF LCD display backlight AUTO MANUAL Power Meter Mode CWDM Scan amp present dBm in single wavelength display mode SCAN Scan amp present dBm in multiple wavelength display mode dB dBm Toggle between measurement units Present scanned dBm wavelength in graphical format Save Save scanned data to instrument s memory ENTER Enter ESC Cancel quit Instrument Setup Scroll up Scroll down Retrieve saved data from ins
14. t data record file to be deleted and press ENTER to select the file Press ENTER to confirm that Data will be deleted or press ESC to quit without deleting and return to the file list display Press ESC to return to Menu Option list 12 01 01 B 12 00 Data Delete 120601 120501 120401 120301 120201 120104 120103 120102 120101 File list display v Data will be deleted LZUIVI 1U UU 12 01 01 B 12 00 Data Delete JJ 120102 08 01 15 User Manual KI6501 Optical CWDM Power Meter 120101 00 00 00 v Revision 3 Page 21 of 27 GFISHER INTERNATIONAL Fiber Optic Test Equipment Manufacturer KI650 1 Opti Cal CW D M Power Meter 6 10 6 Data Format option Use this option to delete all test record files saved in instrument s internal memory See picture below for user interface of this option Press ENTER to confirm that All data will be deleted or press ESC to return to Menu Option list without deleting any record file See picture below 12 01 01 12 00 Menu SCAN Set All data will be deleted Dye Belfast System Info Scan Display v 6 10 7 System Info option Use this option to display the instrument s system information see picture below 12 01 01 G12 00 System Info PN KI 6501 SN 12GXX 000001 HW V2 1 FW V1 0 0 User Manual KI6501 Optical CWDM Power Meter Revision 3 Page 22 of 27 INTERNATIONAL Fiber Optic Test Equip
15. t the highlighted option User Manual KI6501 Optical CWDM Power Meter Revision 3 Page 16 of 27 INTERNATIONAL Fiber Optic Test Equipment Manufacturer KI6501 Opti cal CWDM Power Meter 14 09 260 14 39 14 09 260 14 40 Menu Menu Scan Set Offset Graph Color Auto Power Off lime Set Data Delete Data Format System Info Scan Display PM Scan Mode Menu Option list page 1 2 Menu Option list page 2 2 6 10 1 SCAN Set option This option provide user with the choice of turning the All Scan function ON or OFF See picture below for the user interface When All Scan is ON Selected is OFF The instrument scans its optical input for all 18 wavelengths despite of the wavelengths selected in Select Lambda option see section 6 10 2 When All Scan is OFF Selected is ON The instrument scans its optical input for the wavelengths selected only Use A V to highlight Selected or All Scan and press ENTER to ON When All Scan is ON Selected will be automatically set to OFF and vise versa User Manual KI6501 Optical CWDM Power Meter Revision 3 Page 17 of 27 GFISHER INTERNATIONAL Fiber Optic Test Equipment Manufacturer KI6501 Opti cal CWDM Power Meter 12 01 01 B 12 00 12 01 01 gt 12 00 SCAN Set SCAN Set All Scan ON A e m a Selected Selected Press ENTER to Selected Lambda Selected Lambda 12
16. tching Instrument ON OFF rrrnrrrnnrnnnrrrnnnnnnnrrnnnrrnnnnnnnnsrnnnnnnnnn 9 6 3 PM Power Meter Mode ccccccccsseeeeeeeeeeeeeeeeeaeeeeeeeeeaeeeeeeeeas 10 TM 12 Be CAN MOT EE 12 6 6 Measurement unit dB dBm selection rvrrrnnrrnverrnnnvrrvrnnnnnerveen 13 6 7 Graphical Display Mode rrnnrrnnnnnnnronnrnnnnnvnnnnnnnnnennnnnnnnnennnnnnsnnenn 14 6 8 Saving Scanned Data in Instrument s Memory ccceeeeees 14 6 9 Retrieving Data Save in Instrument rrrrrnnnnnnnnnrovrnnnnrnrnnnnnnnnnnn 15 6 10 Instrument Setup options eee ecccccecceeseeeeeeeeeeeeeeseeeeeeeeeeeeseaas 16 7 Charging of Instrument avsssesssmdgennenendeneee 26 8 Packaging Content ssssununnununnnnnnnunnnnnnnnnnnnnnnnnnnnnnnennnnnnnnnnnnnnnnnnnnnnnnnnnnn 27 9 MAMENANG vr 27 User Manual KI6501 Optical CWDM Power Meter Revision 3 Page 2 of 27 INTERNATIONAL Fiber Optic Test Equipment Manufacturer KI6501 Opti cal CWDM Power Meter 1 Summary KI6501 is an easy and economical handheld CWDM Power Meter for testing multi A single mode fiber optic systems It scans and stores the absolute or relative power levels of all 18 CWDM A in 0 8 seconds Test data can be viewed in graphical or numerical form and reference values can be stored for easy loss testing The instrument has good ergonomics which features a large sunlight readable and backlit colour display and a well laid out and easy to use front panel Data Management
17. trument s memory User Manual KI6501 Optical CWDM Power Meter Revision 3 Page 8 of 27 INTERNATIONAL Fiber Optic Test Equipment Manufacturer KI6501 Optical CWDM Power Meter 6 2 Switching Instrument ON OFF To switch ON instrument press and hold Backlight for 2 seconds The instrument will be defaulted to PM Auto Auto Power Meter Mode upon initialization see pictures below for instrument displays Battery charge indicator Date 12 01 0F GBe12 00 PM Auto When the instrument is switched ON its LCD backlight can be toggled ON or OFF by pressing Backlight Backlight will turn off automatically approx 30 seconds after the last key press To switch OFF instrument press and hold Backlight for 2 seconds The instrument will switch OFF a few second after the display shown below User Manual KI6501 Optical CWDM Power Meter Revision 3 Page 9 of 27 INTERNATIONAL Fiber Optic Test Equipment Manufacturer KI6501 Optical CWDM Power Meter 6 3 PM Power Meter Mode Power Meter can be operated either in PM Auto Mode or PM Manual Mode PM Manual mode displays real time power measurement values PM Auto Mode In this operation mode the instrument automatically scans the optical input and displays the wavelength along with its corresponding measured power value which has been detected with the highest level of power The instrument is defaulted to PM Auto Mode upon power ON otherwise it can be switched from

Download Pdf Manuals

image

Related Search

Related Contents

1507/1503 Insulation Testers  取扱説明書 - 東芝キヤリア株式会社  ICEMOBILE Prime 4.5 User Manual  Chauffages à granulés pf 100 de harman  Control Center and Archive Player  ARCTIC Alpine 64 GT  LELY Discovery 90 SW Nettoyeur d`étable mobile  Télécharger l`article  DeLOCK 4GB USB 2.0 Nano  La culture intensive de saules en courtes rotations  

Copyright © All rights reserved.
Failed to retrieve file