1. Undertightening can cause the product to drop short circuit or malfunction Overtightening can damage screws and or the product causing the product to drop short circuit or malfunction Be sure to shut off the external power supply for the system in all phases before installing or removing the product Failure to do so may damage the product or cause the product to malfunction or fail Do not directly touch any conductive parts and electronic components of the product Doing so can cause the product to malfunction or fail Wiring Precautions Be sure to shut off the external power supply for the system in all phases before installation and wiring Failure to do so may cause an electric shock or damage the product After wiring attach the included terminal cover to the module before turning it on for operation Failure to do so may cause an electric shock Wiring Precautions Use applicable solderless terminals and tighten them within the specified torque range If any spade solderless terminal is used it may be disconnected when the terminal screw comes loose resulting in failure Check the rated voltage and terminal layout and then wire the product correctly Connecting a power supply with a different voltage rating or incorrect wiring may cause a fire or failure Do not install the control lines or communication cables together with the main circuit lines or power cables Keep a distance of 100mm 3 94 inches
2. by force majeure such as earthquakes lightning or wind and water damage 7 Failure caused by reasons unpredictable by scientific technology standards at shipment from our factory 8 Any other failure not attributable to us or which customer identifies not attributable to us 11 EXCLUSION FROM LIABILITY FOR OPPORTUNITY LOSS AND SECONDARY LOSS Regardless of the warranty period we shall have no liability for compensation for any damage caused by reasons not attributable to MEE any opportunity loss or lost profit caused by a failure of our products any damage or secondary damage caused by special circumstances whether or not foreseeable any accident any damage of other manufacturers products or any customer s work such as products replacement readjustment or launch of local machinery equipment etc 12 N FOR YOUR SAFETY This product has been manufactured as a general purpose product for general industry applications etc The product is not designed or manufactured to be used in equipment or systems in situations that can affect or endanger human life When considering this product for operation in special applications such as machinery or systems used in passenger transportation atomic power electric power aerospace or medical applications please contact your nearest Mitsubishi sales representative Although this product was manufactured under conditions of strict quality control the product shall be systematically provid
3. fire failure or malfunction The product must be installed inside the control panel Connect the main power supply to the product inside the control panel through a relay terminal block Only qualified service personnel with knowledge of protection against electric shock should replace and wire the product When connecting the product to the programmable controller check that the product configuration is correct The modules may be failure or malfunction if the configuration is incorrect Use the product with no pressure applied to its connector Failure to do so may cause a breakdown or disconnection Startup and Maintenance Precautions Do not touch any terminal while power is on Doing so can cause an electric shock or malfunction Be sure to shut off the external power supply for the system in all phases before cleaning the product or retightening the terminal screws the mounting screws of the connector or the fixing screws of the product Failure to do so may result in an electric shock or cause the product to fail or malfunction Undertightening can cause the product to drop short circuit or malfunction Overtightening can damage the screw and or product causing the product to drop short circuit or malfunction Startup and Maintenance Precautions N CAUTION Do not disassemble or modify the modules Doing so may cause failure malfunction injury or a fire Use any radio communication device such as a ce
4. occurs in the external power supply or the product Failure to do so may result in an accident due to an incorrect output or malfunction 1 Configure external safety circuits such as an emergency stop circuit protection circuit and protective interlock circuit for forward reverse operation or upper lower limit positioning Configure a circuit to turn on the programmable controller and then the external power supply If the external power supply is turned on first an accident may occur due to an incorrect output or malfunction Design Precautions Do not bundle the control lines or communication cables together with the main circuit lines or power cables Keep a distance of 100mm 3 94 inches or more between them Failure to do so may result in a malfunction due to noise Installation Precautions Be sure to shut off the external power supply for the system in all phases before installation Failure to do so may result in an electric shock Use the product in an environment that meets the general specifications described in this User s Manual Failure to do so may result in an electric shock fire malfunction or the product damage or deterioration Securely fix the product with a DIN rail or mounting screws Incorrect mounting may cause the product to malfunction fail or drop When using the product in a vibration environment secure the product by screws Tighten the screws within the specified torque range
5. or more between them Failure to do so may result in malfunction due to noise Place the cables in a duct or clamp them if not dangling cables may swing or be inadvertently pulled resulting in damage to the product or cables or a malfunction due to poor connection Tighten the terminal screws within the specified torque range Undertightening can cause a short circuit fire or malfunction Overtightening can damage screws and or the product causing the product to drop short circuit or malfunction Tighten the connector screws within the specified torque range Undertightening can cause a short circuit fire or malfunction Overtightening can damage screws and or the product causing the product to drop short circuit or malfunction Connect the connector to the product securely Failure to do so may cause a malfunction When disconnecting a cable from the product do not pull the cable itself For a cable with connector hold the connector and pull it out For a cable connected to a terminal block loosen the terminal block screws before removing the cable Failure to do so may result in a malfunction or damage to the product or cable Before connecting the cables check the type of interface to be connected Connecting the cables to a wrong interface or erroneous wiring may cause the product or external devices to fail Prevent foreign matter such as dust or wire chips from entering the product Such foreign matter can cause a
6. Positioning Module Terminal Block Conversion Module FA LTBQ 75M User s Manual Thank you for purchasing the FA Goods product Before using the product please read this Users Manual and the relevant manuals carefully to ensure correct use MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED SAFETY PRECAUTIONS Always read these precautions prior to use Before using this product please read this User s Manual and the relevant manuals carefully and handle the product properly with full attention to safety The precautions presented in this manual are concerned with this product only For programmable controller system safety precautions refer to the user s manual of the programmable controller used In this manual the safety precautions are classified into two levels N WARNING and N CAUTION Indicates that incorrect handling may cause hazardous N WARNING conditions resulting in death or severe injury Indicates that incorrect handling may cause hazardous N CAUTION conditions resulting in minor or moderate injury or property damage Under some circumstances failure to observe the precautions given under A CAUTION may lead to serious consequences Always follow the precautions of both levels because they are important for personal and system safety Design Precautions Configure safety circuits external to the product to ensure that the entire system operates safely even when a fault
7. ed with backup and fail safe functions when it is used in facilities where breakdowns of the product are likely to cause a serious accident or damage MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED 1 13 5 Kudankita Chiyoda ku Tokyo Japan 102 8404 Our website URL http www mee co jp 50D FA9010 029 B Specifications subject to change without notice Published in June 2015
8. le to us occurs within the terms of the product warranty we shall replace the product free of charge via your local sales office e Terms of warranty The terms of the product warranty shall be one 1 year from the date of purchase or the delivered day to the designated place eScope of warranty 1 The scope of warranty shall be limited to normal use based on the usage conditions methods and environment the specifications or safety precautions of the product etc defined in the instruction manuals 2 The following conditions are not covered with the warranty and subject to charge the product replacement even if the valid warranty period remains 1 Failure resulting from inappropriate storage or handling carelessness or negligence by customer or failure caused by customer s hardware or software design 2 Failure caused by unapproved modifications etc to the product by customer 3 Failure that could have been avoided if when our product was assembled into customer s device safeguards defined by legal regulations applicable to customer s device or functions or structures considered standard by the industry had been provided 4 Failure recognized as preventable if the consumed products specified in instruction manuals etc were normally maintained or replaced 5 Replacement of consumable parts relays etc 6 Failure caused by external factors beyond anyone s control such as fires or abnormal voltage and failure caused
9. llular phone or PHS Personal Handy phone System more than 25cm 9 85 inches away in all directions from the programmable controller this product Failure to do so may cause malfunction Shut off the external power supply for the system in all phases before mounting or removing the module Failure to do so may cause the module to fail or malfunction or damage After the first use of the product do not mount remove the module and the cable more than 50 times IEC 61131 2 compliant respectively Exceeding the limit of 50 times may cause malfunction Startup and maintenance of a control panel must be performed by qualified maintenance personnel with knowledge of protection against electric shock Lock the control panel so that only qualified maintenance personnel can operate it Before handling the module touch a grounded metal object to discharge the static electricity from the human body Failure to do so may cause the module to fail or malfunction Disposal Precautions N CAUTION When disposing this product treat it as industrial waste Transportation Precautions Avoid the shock that exceeds the shock resistance described in the general specifications during transportation as the product is a precision device Failure to do so can cause the product to fail if halogen based materials fluorine chlorine bromine iodine etc infiltrate into our products the products will be damaged Halogen based materials are
10. mplifier When connected to Mitsubishi Electric Corporation MR J4 Series Install the connector securely to the PLC module with mounting screws Connection cable between positioning module and conversion module FA CBL Q 7 Insert the connector fully to connect it securely Manual pulsar all external signals Programmable controller module QD75M1 or others 7 EXTERNAL CONNECTION EXAMPLE Note The Manual pulse generator please use HR HDPO1 manufactured by Mitsubishi Corporation 1 When the QD75M connection PULSER B PULSER B a PULSER A Connection example Manual pulse generator 2 When the QD75MH connection TBI 112 3 4 5 6 7 819 h10 PULSER B PULSER B PULSER A PULSER A m P5 SG SG EMLCOM EM O O O O gt E ipams Connection example Manual pulse generator 3 When the QD77MS connection TBI 1 2 3 4 5 6 7 8 9h10 I 1 co ao lt c lt c mei faai fani Oo 5 aa ME Ee Connection OOOO example B A Manual pulse generator cut ccc Input signal TB2 112 13 4 5 6 7 8 2 STOP 1 STOP 2 D0G 1 DOG Input signal 2 RLS 1 RLS 2 FLS 1 FLS NC NC NC NC Input signal 10 8 APPLICABLE SOLDERLESS TERMINALS Pipe Rn Ye Applicable Non insulated Insulated Non insulated Insulated Manufacturer l l wire size solderless termi
11. nal solderless terminal solderless terminal solderless terminal 1 25Y 3 TGV 1 25Y 3 R1 25 3N TG 1 25 3N TGV 1 25Y 3N 2 Nichifu Co Ltd 9 3 17 25mm R1 25 3 5N TG 1 25 3 5N TGY1 25Y 3L NTM TGn1 25Y 3 5 Ae 3 TGY2Y 3 V N 1 25 2 0mm R2 3N TG X2 3N 2Y 3 5S TGY2Y 3 58 1 25 B3A Japan Solderless 9 3 1 25mm 1 25 MS3 V1 25 MS3 a Terminal Co Ltd 1 25 C3 5A JST vemss 2 N3A 4 25 2 0mm 25 2 0mm 2 2MS3 0 V2 v2MS3 2 M3A V2 N3A gt R1 25 3ML RAV1 25 3ML VD1 25 3L VDAV1 25 3L Nippon Tanshi 0 3 1 25mm R123 coy AA VD1 25 3 5SS VDAV1 25 3 5SS Co Ltd _ VD1 25 3 5S VDAV1 25 3 5S HE VD2 3S NTK A i RAV2 3SL i VDAV2 3 5SS 1 25 2 0mm R2 3SL RAP2 3SL o D Solderless terminal dimensions Unit mm Round non insulated Round insulated solderless terminal solderless terminal Y non insulated Y insulated solderless terminal solderless terminal e Terminal block pet Unit mm 7 62 1 22 6 4 _ 8 84 11 9 PRECAUTIONS 1 For wiring to the terminal block refer to the manual of the connected programmable controller module published by Mitsubishi Electric Corporation 2 Ground the FG wire provided with the cable in the same manner as the programmable controller module Note that the bunched up extra wire without grounding may act as an antenna possibly introducing noise 10 COVERAGE OF WARRANTY If any fault or defect hereinafter referred to as failure attributab
12. nnot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual 2015 MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED 1 INTRODUCTION This User s Manual describes the specifications and others of the terminal block conversion modules used in combination with Mitsubishi Electric Corporation positioning modules 2 GENERAL SPECIFICATIONS ltem Specifications Operating ambient O to 55 C temperature Storage ambient 25 to 75 C temperature Operating ambient a 5 to 95 RH no condensation humidity Storage ambient Re 5 to 95 RH no condensation humidity JIS B 3502 IEC61131 2 Under 5 to 8 4Hz 10 times each in X Y Vibration resistance intermittent mma Vaa 8 4 to 150Hz a and Z directions Under 5 to 8 4Hz continuous A Compliant with JIS B 3502 and IEC61131 2 147m s 15G 3 times each in X Y and Z directions Conforming standards Frequency Acceleration Shock resistance Operating No corrosive gas atmosphere Operating altitude Installation location 2 000m or lower Inside the control panel Overvoltage 2 Il or lower category Pollution level 2 or lower 1 Do not use or store the module under the atmospheric pressure greater than that at an altitude of Om 2 Indicates the section of the power supply to which the equipment is assumed to be c
13. often included in fumigant which is used to sterilize or disinfest wooden packages Prevent residual fumigant components from being infiltrated into our products or use an alternative sterilization or disinfection method heat disinfection etc Additionally use the wooden package made of woods sterilized and protected against insects as a measurement REVISIONS The manual number is given on the bottom left of the last page September 2011 March 2014 June 2015 S0D FA9010 029 S0D FA9010 029 A S0D FA9010 029 B First edition Added or modified parts 4 CONNECTED TARGET MODEL PLC MODULE CONNECTION CABLE 6 INSTALLATION METHOD 7 EXTERNAL CONNECTION EXAMPLE 9 Gratis Warranty Terms and Gratis Warranty Range 10 Exclusion of Opportunity Loss and Secondary Loss from Warranty Liability mAdded or modified parts SAFETY PRECAUTIONS REVISIONS 1 INTRODUCTION 2 GENERAL SPECIFICATIONS 3 PERFORMANCE SPECIFICATIONS 9 PRECAUTIONS a Modified English sentences SAFETY PRECAUTIONS 2 GENERAL SPECIFICATIONS 3 PERFORMANCE SPECIFICATIONS 6 INSTALLATION METHOD 8 APPLICABLE SOLDERLESS TERMINALS 10 COVERAGE OF WARRANTY 11 EXCLUSION FROM LIABILITY FOR OPPORTUNITY LOSS AND SECONDARY LOSS FOR YOUR SAFETY Japanese manual number 50D FA9010 014 This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation ca
14. onnected between the public power grid and the machinery within the premises 3 This is a guideline indicating the degree of the generation of conducting substances in the environment in which a device is used 3 PERFORMANCE SPECIFICATIONS aa nani FA LTBQ75M Number of supported axes 2 axes 2 units used for 4 axes Rated voltage 24 VDC CLASS 2 Input Rated current signals Used voltage 4 5 to 26 4 VDC CLASS 2 range M3 screws 7 62 mm pitch ee Applicable wire 0 5 to 1 25mm Tightening torque Terminal screw tightening torque range 50 to 75N cm 5 2 to 7 6kgf cm 4 CONNECTED TARGET MODEL PLC MODULE CONNECTION CABLE PLC Module Model Cable Model between Module Model Connected Devices PLC Module QD75M1 QD75M2 QD75M4 MELSEC Q QD75MH1 External devices Series QD75MH2 FA CBL Q7 FA LTBQ75M Connection signals connector type QD 75MH4 For terminal block conversion QD77MS2 Note 1 Note 2 QD77MS4 Note 1 Note 2 QD77MS16 Note 1 Note 2 Note 1 The following signals to connecting differential output type of manual pulse generator Incremental synchronous encoder will not use QD77MS HAH HAL HBH HBL Note 2 Units shall use to be replaced with signal names as the following FA LTBQ75M QD77MS Terminal names Signal names o asn wm o ms f e 5 EXTERNAL DIMENSIONS Unit mm DIN rail center 6 INSTALLATION METHOD Connection example of PLC positioning module and servo a
Download Pdf Manuals
Related Search
FA LTBQ75M
Related Contents
Wiley Professional Papervision3D Chapter 6 - AutomationDirect separatore di linea per sistema duo line buffer for duo system /9 Cliccate qui per un nuovo Listen Technologies LA-319 User's Manual 取扱説明書 mode d`emploi ordinateur de pulvérisation 4000 Télécharger le mode d`emploi de la CCI PCS-G50 Copyright © All rights reserved.