Home
Quick Start Guide
Contents
1. Agilent Protocol Analyzer and Jammer for USB Quick Start Guide whee Agilent Technologies Notices Agilent Technologies Inc 2011 No part of this manual may be reproduced in any form or by any means including electronic storage and retrieval or transla tion into a foreign language without prior agreement and written consent from Agi lent Technologies Inc as governed by United States and international copyright laws Manual Part Number U4611 97000 Printed in Malaysia in October 2011 Edition First Edition October 2011 Agilent Technologies Inc 1900 Garden of the Gods Road Colorado Springs CO 80907 USA Sales and Technical Support To contact Agilent for sales and technical support refer to the support links on the following Agilent web resources www agilent com find product specific information and support software and doc umentation updates www agilent com find contactus world wide contact information for repair and ser vice Information on preventing damage to your Agilent equipment can be found at www agilent com find tips Declaration of Conformity Declarations of Conformity for this product is provided with the product shipment Warranty The material contained in this docu ment is provided as is and is subject to being changed without notice in future editions Further to the maxi mum extent permitted by applicable law Agilent disclaims all warrantie
2. This Quick Start Guide provides information to assist you with performing basic operations on Agilent U4611 USB 3 0 2 0 Protocol Analyzer and Agilent U4612 USB 3 0 Protocol Jammer Step 1 Installing the Software 1 Download the Agilent Protocol Tester software available for U4611 USB Analyzer and U4612 USB Jammer from the Agilent Web site at www agilent com find usb protocol 2 Once the application software install package is downloaded double click the Setup_ProtocolTester exe The installation of the needed drivers and other utilities for the use of the U4611 USB Analyzer or U4612 USB Jammer hardware should begin Microsoft Visual C Runtime if needed WinDriver from Jungo if needed Java Runtime Environment if needed 3 Depending on the method used to connect the host PC to U4611 USB Analyzer or U4612 USB Jammer hardware you may need to reboot the host PC ofits Agilent Technologies 1 Getting Started Step 2A Using Gigabit Ethernet 1 Power on and attach the U4611 USB Analyzer or U4612 USB Jammer hardware to company network or a GbE switch Access the Agilent Protocol Tester software Choose the U4611 USB Analyzer or U4612 USB Jammer hardware you wish to connect to a If the selected hardware is detected as In Use shown with a lock symbol click to determine who is currently using the hardware b Click OK You should now be able to set up your U4611 USB Analyzer or U4612 USB Jammer for
3. folder in the program directory where the Protocol Tester software is installed You can also access the online help by clicking Help and choosing the appropriate option from the Protocol Tester software For help with the more advanced features please read the manuals If your question is not answered feel free to contact Technical Support Support is available through Agilent s website www agilent com find contactus Agilent Protocol Analyzer and Jammer for USB Quick Start Guide 13 14 Copyright Agilent Technologies 2011 Printed in Malaysia October 2011 U 1 9 000 x 4 6 7
4. radiation turned on e CSA is the Canadian certification mark to demonstrate compliance with the Safety requirements The C tick mark is a registered trademark of the Spectrum Management Agency of Australia This signifies compliance with the Australia EMC Framework regulations under the terms of the Radio Communication Act of 1992 N10149 ISM GRP 1A classification according to the international EMC standard CE CE compliance marking to the EU Safety and EMC Directives ICES NMB 001 compliance marking to the Canadian EMC standard ISM GRP 1 4 General Safety The following general safety precautions must be observed during all Precautions phases of operation of this instrument Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design manufacture and intended use of the instrument Agilent Technologies Inc assumes no liability for the customer s failure to comply with these requirements Before operation review the instrument and manual for safety markings and instructions You must follow these to ensure safe operation and to maintain the instrument in safe condition General This product is a Safety Class 1 instrument provided with a protective earth terminal The protective features of this product may be impaired if it is used in a manner not specified in the operation instructions Agilent Protocol Analyzer and Jammer for USB Quick Start Guide
5. the model of the U4611 USB Analyzer hardware that you purchased there are a variety of different test scenarios and cabling needed to monitor traffic Below are some diagrams of typical test setups silent U46114 B AB USB 3 0 Device USB 3 0 2 0 Analvzer Figure 1 U4611 USB Analyzer Setup Diagram If you want your USB 3 0 device to come up as a USB 2 0 device plug the included USB 2 0 extender cable into the device side Step 4 Setting Up U4611 USB Analyzer for Recording a Trace The U4611 USB Analyzer settings menu is used to determine the type of recording method trigger position in the buffer buffer size and speed of the ports The U4611 USB Analyzer supports the following three different methods for Stop Mode e Manual Stop This will cause the U4611 USB Analyzer to continually record traffic until either the Stop button is clicked or the Manual Trigger button on U4611 USB Analyzer is pressed e Stop when full This will cause the U4611 USB Analyzer to record traffic until the specified buffer size is full e Trigger This allows specification of an event or a series of events Agilent Protocol Analyzer and Jammer for USB Quick Start Guide Getting Started 1 The Trigger Position slider is only used when the Trigger mode is specified and allows the user to determine how much traffic is captured before and after the trigger event Buffer size is used to specify how large of a trace is desired Step 5 Setti
6. 3 Environment Conditions Before Applying Power Ground the Instrument Do Not Operate in an Explosive Atmosphere Do Not Remove the Instrument Cover Environmental Information All Light Emitting Diodes LEDs used in this product are Class 1 LEDs as per IEC 60825 1 This instrument is intended for indoor use in an installation category II pollution degree 2 environment It is designed to operate at a maximum relative humidity of 95 and at altitudes of up to 2000 meters Refer to the specifications tables for the ac mains voltage requirements and ambient operating temperature range Verify that all safety precautions are taken The power cable inlet of the instrument serves as a device to disconnect from the mains in case of hazard The instrument must be positioned so that the operator can easily access the power cable inlet When the instrument is rack mounted the rack must be provided with an easily accessible mains switch To minimize shock hazard the instrument chassis and cover must be connected to an electrical protective earth ground The instrument must be connected to the ac power mains through a grounded power cable with the ground wire firmly connected to an electrical ground safety ground at the power outlet Any interruption of the protective grounding conductor or disconnection of the protective earth terminal will cause a potential shock hazard that could result in personal injury Do not operate th
7. Trigger example You can add additional events to the state for an OR and new states for an AND In the following example the U4611 USB Analyzer is looking for a UAS Command IU followed by a UAS Sense IU O Mew Wait for drag events here wait for 1 of those events n Mars Storage TU UAS SENSE TU Add sdlected event drag ewents here Then Trigg Add action New Wait for drag events here Figure 4 Trigger example Agilent Protocol Analyzer and Jammer for USB Quick Start Guide Getting Started 1 In this example note the Then action in State 1 as Branch to State 2 In State 2 a UAs Sense IU is specified to cause the trigger There are other options and actions that can be used to create more thorough triggers and live counters For more information refer to the Agilent Protocol Analyzer and Jammer for USB User s Manual that gets installed with the Agilent Protocol Tester software After you have configured the U4611 USB Analyzer settings filters and triggers click the pr button to start the Start Capt data capture using U4611 USB Analyzer Step 7 Monitoring the Status After stating the capture you can monitor its status by clicking the et Status button Status All capture related information is shown in the Status page Capturing Triggered 1 U46114 Analyzer SM 13912015 Filt
8. e instrument in the presence of flammable gases or fumes Operating personnel must not remove instrument covers Component replacement and internal adjustments must be made only by qualified personnel Instruments that appear damaged or defective should be made inoperative and secured against unintended operation until they can be repaired by qualified service personnel This product complies with the VWEEE Directive ZU02 96 EC marking requirements The affixed label indicates that you must not discard this electricals electronic product in domestic household waste Product Category WTR reference fo fhe equioment fyoes In fe WEEE Orective Annex l this product is gassed as a Monitoring and Control instrumentation product Do not dispose in domestic household waste To return unwanted products contact your local Agilent office or see wan agilent comfenvironmentiproduct for more information Agilent Protocol Analyzer and Jammer for USB Quick Start Guide Agilent Protocol Analyzer and Jammer for USB Quick Start Guide 1 Getting Started Step 1 Installing the Software 5 Step 2A Using Gigabit Ethernet 6 Step 2B Configuring Ethernet 6 Step 2C Using PCI Express 7 Step 3 Connecting Your U4611 USB Analyzer in a Test Setup 8 Step 4 Setting Up U4611 USB Analyzer for Recording a Trace 8 Step 5 Setting Up Filters 9 Step 6 Setting Up a Trigger 9 Step 7 Monitoring the Status 11 Step 8 Viewing the Trace 12
9. er Settings Applying filter USE 3 0 100 E Pre trigger data E Trigger E Post trigger data E Stop Curent 49 mA Voltage JaA V Fort Active Host Device Power Speed 55LFPS SSlink GbE Packet Run 6 Ero Trig d Analysis 2 0 SUSP QUser cfg o mow LS FS HS 55 Sequencer State Sequencer 1 State 1 Figure 5 Status page Agilent Protocol Analyzer and Jammer for USB Quick Start Guide 11 1 12 Getting Started The LEDs displayed in the Status page replicate those found in the front of the U4611 USB Analyzer hardware allowing for easy monitoring of Link status The pie charts see Figure 5 above show the status of the buffer and pre post data if specified This example displays how much data was captured before and after the trigger point If the desired amount of data is captured and the U4611 USB Analyzer is still running click the on button Stop Capt After either clicking the Stop Capture button or if the Analyzer has finished filling up the buffer it will automatically upload and display the trace Step 8 Viewing the Trace There are several different viewing options for a trace The following is a list of these viewing options e Protocol View shows the precise timing relationship between each DWORD in the trace e Transaction View shows each fully populated command in the order it was initiated a Spreadsheet View shows extens
10. ive decoding of link commands protocol packets commands ACKs etc in time ordered occurrence e Histogram shows a high level time based graphical representation of user specified events e Frame Details shows selected frame in the format used by USB specifications e ioe Data Viewer shows the selected Data Frame payload in several different formats E Statistics shows performance and other link command related measurements Agilent Protocol Analyzer and Jammer for USB Quick Start Guide Getting Started 1 Each of the above listed button corresponds to a different view of the traffic and multiple views can be shown and manipulated at the same time Double click on any event in any of the views and it will sync the rest of the views with the event You can also search and or hide show events in the trace using the different buttons below 0 Qs I D Quick Search allows the user to type the desired search term e Advanced Search provides a way to search for sequences of events either within a frame or across multiple frames and events e Quick Hide bar allows for quick hiding of selected primitives and link events o Advanced _ Advanced Filter provides a way to show or hide detected addresses or sequences of events Advanced Options Further information on both the U4611 USB Analyzer and U4612 USB Jammer hardware and software is available in the Online help and User guide in the Doc
11. n Restricted Rights as defined in FAR 52 227 19 c 1 2 June 1987 U S Govern ment users will receive no greater than Limited Rights as defined in FAR 52 227 14 June 1987 or DFAR 252 227 7015 b 2 November 1995 as applicable in any technical data Safety Notices This manual provides these notices CAUTION A CAUTION notice denotes a haz ard It calls attention to an operat ing procedure practice or the like that if not correctly performed or adhered to could result in damage to the product or loss of important data Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met A WARNING notice denotes a hazard It calls attention to an operating procedure practice or the like that if not correctly per formed or adhered to could result in personal injury or death Do not proceed beyond a WARNING notice until the indicated condi tions are fully understood and met Safety Summary Safety Symbols Indicates warning or caution If you see this symbol on a product you must refer to the manuals for specific Warning or Caution information to avoid personal injury or damage to the product Frame or chassis ground terminal Typically connects to the equipment s metal frame A Indicates hazardous voltages and potential for electrical shock a Indicates that antistatic precautions should be taken Indicates hot surface Please do not touch A Indicates laser
12. ng Up Filters Filter settings are used to filter out specified patterns while capturing traffic and maximizing the buffer usage To set a filter select the checkbox of the type of data that you want to capture and deselect the checkboxes of the type of data that you do not want to capture For example to filter out USB 2 0 SOFs NAKs CSPLITs NYETs Bus States and USB 3 0 Pings ITPs and SKPs use the settings displayed in the following screen ee a riyar ae Figure 2 Filter settings Step 6 Setting Up a Trigger If Trigger is selected in the Analyzer Settings page the Trigger button should be available to click If the button is greyed out it means that Trigger is not selected as the Stop Mode option For setting up a basic trigger navigate to the desired trigger event and click and drag it to the sequencer pane Make sure Trigger is selected in the Then listbox Note the option to Agilent Protocol Analyzer and Jammer for USB Quick Start Guide 1 10 Getting Started change any of the specified fields to match a specific event The example below shows a trigger event on a UAS Command IU In this example you can expand the sign displayed with the UAS Command IU to edit individual field values to narrow down the Command IU matches n Mass Storage IU UAS COMMAND IU Add selected event drag events here Then Trigger Add action New Wait for drag events here Figure 3
13. on the U4611 USB Analyzer or U4612 USB Jammer hardware Power on the host PC This is for proper Windows Kernel initialization Open the Agilent Protocol Tester software Choose the U4611 USB Analyzer or U4612 USB Jammer hardware you wish to connect to If the selected hardware is detected as In Use shown with a lock symbol click to determine who is currently using the U4611 USB Analyzer or U4612 USB Jammer hardware Click OK For using PCI ExpressCard adapter with laptop 1 Verify that the laptop has an ExpressCard port as it is not compatible with CardBus or PCMCIA Install ExpressCard adapter into ExpressCard slot in the laptop Connect a PCIe cable from the host laptop to the U4611 USB Analyzer or U4612 USB Jammer hardware Power down the host laptop before powering up the U4611 USB Analyzer or U4612 USB Jammer hardware Power on the U4611 USB Analyzer or U4612 USB Jammer hardware Then power on the host laptop This is for proper Windows Kernel initialization Agilent Protocol Analyzer and Jammer for USB Quick Start Guide 1 Getting Started 6 Open the Agilent Protocol Tester software 7 Choose the U4611 USB Analyzer or U4612 USB Jammer hardware you wish to connect to 8 If the selected hardware is detected as In Use shown with a lock symbol click to determine who is currently using the hardware 9 Click OK Step 3 Connecting Your U4611 USB Analyzer in a Test Setup Depending on
14. s either express or implied with regard to this manual and any information contained herein including but not lim ited to the implied warranties of mer chantability and fitness for a particular purpose Agilent shall not be liable for errors or for incidental or consequen tial damages in connection with the furnishing use or performance of this document or of any information con tained herein Should Agilent and the user have a separate written agree ment with warranty terms covering the material in this document that conflict with these terms the warranty terms in the separate agreement shall con trol Technology Licenses The hardware and or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license Restricted Rights Legend If software is for use in the performance of a U S Government prime contract or sub contract Software is delivered and licensed as Commercial computer soft ware as defined in DFAR 252 227 7014 June 1995 or as a commercial item as defined in FAR 2 101 a or as Restricted computer software as defined in FAR 52 227 19 June 1987 or any equivalent agency regulation or contract clause Use duplication or disclosure of Software is subject to Agilent Technologies standard commercial license terms and non DOD Departments and Agencies of the U S Gov ernment will receive no greater tha
15. use Step 2B Configuring Ethernet When using a direct connection or a switch that does not support DHCP you may need to change your TCP IP setting in Windows to connect to the Agilent Protocol Analyzer and Jammer for USB hardware 1 Open the Network Connections and right click Local Area Connection and then click Properties Click TCP IP and then click the Properties button Specify IP address as 10 0 0 1 and subnet mask as 255 0 0 0 and then click OK You should now be able to connect to the U4611 USB Analyzer or U4612 USB Jammer When you need to set up a static IP 1 Use the method described above to connect to U4611 USB Analyzer or U4612 USB Jammer hardware Right click the U4611 USB Analyzer or U4612 USB Jammer and select Modify Static IP Specify the desired static IP address and click OK To check the current IP address of U4611A B or U4612A press and hold the trigger button for 3 seconds and then release it The IP address will be displayed one digit at a time on the 7 segment LED Agilent Protocol Analyzer and Jammer for USB Quick Start Guide Getting Started 1 Step 2C Using PCI Express For using PCI Express x4 adapter card with desktop or server PC 1 2 Install PCI Express x4 adapter into the host PC Connect a PCIe cable from the host PC to the U4611 USB Analyzer or U4612 USB Jammer Power down the host PC before powering up the U4611 USB Analyzer or U4612 USB Jammer hardware Power