Home

ZN-DN312XE-M Manual

image

Contents

1. 01401 GANZ 20 ZN DN312XE M Installation Guide REVISION HISTORY MAN DATE M D Y Comments O1A 01 05 24 2012 First release version O1A 01 21
2. H 264 FULL HD NETWORK INDOOR DOME ZN DN312XE M Installation Manual AGA ZN DN312XE M Installation Guide INFORMATION TO USER RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK CONTACT QUALIFIED SERVICE PERSONNEL FOR INTERNAL PARTS This symbol is intended to alert the user the presence of un insulated dangerous voltage within the product s enclosure which may be sufficient magnitude to constitute an electric shock risk to persons This symbol is intended to alert the user the presence of important operating and maintenance servicing instructions within the guide manual O1A 01 ZN DN312XE M Installation Guide Table of Contents did uide 4 2 PACKAGE CONTENTS 5 3 PART NAMES 6 INSTALLATION nnie A E EEEE E e 7 AALS TEMPLO ert 8 4 2 Setting the Lens Position ui 9 4 3 Setting the Mage AttribUte nr nn ni a Ea estes 9 5 CONNEGTIONS TION ITE CD III 10 6 CONFIGURATION eie eren ep ron vea nueva res evan Reo eeu nic nia ne neo au een Les TA ATA 13 6 1 Set up network environment 13 6 2 View video on web 13 6 2 1 View video usin
3. Users may view the live streaming images on a web page using the device s IP address To have the correct IP address ready and access through a web page 1 Convert a MAC address to an IP address check the IP address on the IPAdminTool Refer to Appendix D Hexadecimal Decimal Conversion Table The MAC address is attached on the side or bottom of the device MAC address 00 13 23 01 14 B1 IP address 192 168 20 177 the Hexadecimal number to Decimal number 2 Open a web browser and enter the IP address of the device 3 Grant the Security Certificate Alert and install the ActiveX if those have not been completed yet 4 Wait for a few seconds while the web page loads The live streaming image is displayed 1 While the device is in use press the Reset button 2 Waitfor the system to reboot 6 4 Factory Default 1 Pressreset button and hold 2 Release the Reset button after LED blinks for 5 seconds 3 Wait for the system to reboot The factory default settings are described as below IP address 192 168 xx yy Network mask 255 255 0 0 Gateway 192 168 0 1 User ID root Password pass 01401 GANZ 15 ZN DN312XE M Installation Guide APPENDIX A SPECIFICATIONS Summary Camera Module Image Sensor 1 2 7 1080p CMOS CMOS Effective Pixels 1920x1080 Scanning system Progressive scanning Resolution 1920 x 1080 Min Color 1 0 lux F1 2 PRESITRICAL Illuminatio
4. Two way mono audio k RTSP HTTP protocol 10 100 Base T Ethernet Additional Features 01A 01 Micro SD card PoE supported Built in Video Content Analysis Internal fan SDK Software Development Kit provided ZN DN312XE M Installation Guide 2 PACKAGE CONTENTS The package contains main camera DC power adaptor DC jack cable 9 pin and 2 pin terminal blocks video out cable screws anchors hex wrench driver and clamping cores Unpack carefully and handle the equipment with care Camera DC power adaptor P SO X di DC Jack Cable Video out cable Screws and anchors A Quick installation guide Hex wrench driver A Clamping core To prevent electromagnetic interference The above contents are subject to change without prior notice Note 014 01 GANZ 5 ZN DN312XE M Installation Guide 3 PART NAMES Models herein and their appearance are subject to change without any prior notice Fan The fan and heater underneath the black panel are equipped dehumidify and extract heat from internal parts Reset button The reset button can be used for restarting the device or resetting back to Factory Default Refer to 6 3 Reset and 6 4 Factory Default for more details Reset button is located under PCB Visual standard output configuration switch The first switch SW1 sets the visual standard output fsystem Pressing this button conv
5. F 122 PoE 0 C 50 C 32 F 122 F Operating Humidity Up to 85 RH Mechanical Condition Material Plastic ABS Color Ivory Dimension Housing 144 x 121 H mm Dome 100 0 mm Weight Approx 520g 01401 GANZ 17 ZN DN312XE M Installation Guide APPENDIX B POWER OVER ETHERNET The Power over Ethernet PoE is designed to extract power from a conventional twisted pair Category 5 Ethernet cable conforming to the IEEE 802 3af Power over Ethernet PoE standard The IEEE 802 3af 2003 standard allows up to 15 4 W power to device However 12 95W is the maximum available power as some power gets lost in the cable PoE has advantages over conventional power in such places where AC powers cannot be reached or expensive to wire The device s power consumption is 5 28 W or 5 40W when the fan is on Note For proper activation of 12V PoE the Category 5 cable must be shorter than 140m and conform the PoE standard PoE compatibility With non Power Sourcing Equipment PSE When it is connected with non PSE the power adaptor should be used With power adaptor Connecting both PSE and power adaptor do not cause any harms to the products Disconnecting power adaptor while it is operating does not stop operation The product continues to work without rebooting The PoE Power Class supported by the IP device is Class 0 Class Usage Minimum Power Levels Maximum Power Levels at Output at the
6. non vibrating surfaces If the stability is in doubt consult with safety personnel for reinforcements and then proceed with the installation Caution 01401 GANZ 7 ZN DN312XE M Installation Guide 4 1 Installation Template Installation template image s size scale in this installation guide is not 1 1 The correct size template design paper can be found inside the package separately Caution 01401 GANZ ZN DN312XE M Installation Guide 4 2 Setting the Lens Position Instruction below describes how to set the lens positions and manually adjust zoom and focus 1 Remove the dome cover 2 Adjust the lens to the desired position by manually moving its reinforced body upper lens shell or horizontal platform in the following directions A Rotate the lens B Pan the lens with C Tilt the lens with with upper lens shell reinforced lower body horizontal platform Connect to the web page of the device to see its real time image Refer to step 6 Configuration for details about using its web page 3 Configure each setting of 6 switches as below B Pan the lens with reinfprcedjawer body sw2 SW3 PAL NTSC TELE WIDE SWA SW5 SW6 FAR NEAR d Focus 4 3 Setting the Image Attribute Through the camera s webpage users can configure image settings The camera image s brightness contrast saturation and s
7. 160 C5 197 234 OD 13 32 50 57 87 7C 124 A1 161 C6 198 EB 235 OE 14 33 51 58 88 7D 125 A2 162 C7 199 EC 236 OF 15 34 52 59 89 7E 126 A3 163 C8 200 ED 237 10 16 35 53 5A 90 127 A4 164 9 201 238 11 17 36 54 5 91 80 128 AS 1165 202 EF 239 12 18 37 55 5 92 81 129 166 203 FO 240 13 19 38 56 5 93 82 130 7 167 CC 204 1 241 14 20 39 57 5E 94 83 131 A8 168 CD 205 F2 242 15 21 3A 58 5F 95 84 132 A9 1169 CE 206 F3 243 16 22 3B 59 60 96 85 133 AA 170 CF 1207 FA 244 17 23 60 61 97 86 134 171 208 5 245 18 24 30 61 62 98 87 135 172 01 209 F6 246 19 25 62 63 99 88 136 AD 173 02 210 7 247 1A 26 3F 63 64 100 89 137 174 03 211 8 248 1B 27 40 64 65 101 138 AF 175 04 212 F9 249 1C 28 41 65 66 102 8B 139 BO 176 05 213 250 10 29 42 66 67 103 8 140 1 177 D6 214 251 1 30 43 67 68 104 8D 141 2 178 7 215 252 1F 31 44 68 69 105 8E 142 B3 179 D8 216 FD 253 20 32 45 69 106 8 143 4 180 09 217 254 21 33 46 70 6 107 90 1144 5 181 DA 218 FF 255 22 34 47 71 6 108 91 145 B6 182 DB 219 23 35 48 72 6D 109 92 146 B7 183 DC 220 24 36 49 73 6E 110 93 147 B8 184 DD 221
8. PSE the Powered Device 0 Default 15 4W 0 44 to 12 95W 01401 GANZ 18 ZN DN312XE M Installation Guide Unit mm 01401 GANZ 19 ZN DN312XE M Installation Guide APPENDIX D HEXADECIMAL DECIMAL CONVERSION TABLE Refer to the following table when converting the MAC address of the device to the IP address Dec Hex Dec Dec Dec Hex Dec Dec Dec 00 0 25 37 74 6F 111 94 148 B9 185 DE 222 01 1 26 38 4B 75 70 112 95 149 BA 186 DF 223 02 2 27 39 4C 76 71 113 96 150 BB 187 EO 224 03 3 28 40 4D 77 72 114 97 151 188 E1 225 0414 29 41 4E 78 73 115 98 152 BD 189 E2 226 05 5 2 42 4F 79 74 116 99 153 190 227 06 6 2B 43 50 80 75 117 154 191 228 07 7 2C 44 51 81 76 118 9B 155 192 5 229 08 8 20 45 52 82 77 119 9C 156 1 193 230 09 9 2E 46 53 83 78 120 90 157 2 194 7 231 10 2F 47 54 84 79 121 9E 158 C3 195 E8 232 OB 11 30 48 55 85 7 122 9F 159 C4 196 E9 233 12 31 49 56 86 7 123
9. e amp LAN connection This is a RJ45 LAN connector for 10 100 Base T Ethernet Connect a LAN cable LED LED Green Orange When the device is powered on both LEDs blink for a second Then the orange LED turns on initially for a while and eventually green LED turns on when the device is ready 6 12V DC Power A 12 DC power connector is required for this device 12V Black Red 01401 GANZ 12 ZN DN312XE M Installation Guide 6 CONFIGURATION 6 1 Set up network environment The default IP address of your IP device is 192 168 XXX XXX Users can identify the IP address of the device from converting the MAC address hexadecimal numbers which is attached to the device Please make sure the device and the PC are on the same area network before running the installation If the area network between the PC and the device is different change the PC s settings as described below address 192 168 Subnet mask 255 255 0 0 Internet Protocol TCP IP Properties UL General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically O Use the following IP address IP address 10 10 Default gateway Use the following DNS server addresses Preferred DNS server Al
10. erts the video output standard to NTSC PAL or Off Video output audio and IO terminal connector A 9 pin terminal block is included in the device package Connect this terminal block into this connector for cable connection of video output audio input output and digital input output Refer to 5 1 Connector for more details LAN connector This is a RJ45 LAN connector for 10 100 Base T Ethernet Micro SD card slot It is a memory card slot for external storage Power Adaptor Connector DC 12V The camera requires a DC 12V 1A power adapter 01401 GANZ 6 ZN DN312XE M Installation Guide 4 INSTALLATION 1 Place the installation template x paper that is included in the package gt on the desired installation surface 2 Drill three holes in correct positions based on the template paper and insert anchor blocks into the holes 3 Place the camera body and match three alignment holes with three anchor blocks Fasten the camera with screws 4 Connect all the required cables to the camera 5 Adjust the lens position Detailed information can be found in 4 2 Setting the Lens Position 6 Place the dome cover on the main body of the camera Dome cover has three alignment holes that match camera body s alignment holes 7 Once properly placed insert 7 alignment screws into the three holes zati of the body and fasten them up To prevent products from damaging place the camera on stable and
11. g IPAdmin Tool riiit ii iiie i ii a 14 6 2 2 View video using IP address 15 15 6 4 Factory Default parar A ieue DA DE 15 APPENDIX A SPECIFICATIONS ai cecsiscssivssesvsnnsdevessvsdvevanvedans 16 SUMAI sete aeterne hu t n E E E LEE ntes 16 Electrical Characteristics x eoo tae eoo reae eae erae a e ea eR E aea oaaae daaa 17 Environment GonditlOnia eco adatta rana ada eeu auno de a eeu ea uno Cede a o 17 Mechanical Condition 17 APPENDIX B POWER OVER ETHERNET creen eene eee eene nnn nennen eese enn n nnns 18 POE compatibility rrr rere reo yag EY ANA 18 Power classification iii 18 APPENDIX C 19 APPENDIX D HEXADECIMAL DECIMAL CONVERSION 20 REVISION HISTORY al E 21 01401 GANZ 3 ZN DN312XE M Installation Guide 1 FEATURES Camera Full HD indoor dome IP camera Vandal proof High quality compression in real time streaming 1 2 7 High Quality CMOS Image Sensor True Day Night ICR and WDR Improved color rolling suppression Streaming Dual streaming mode De interlacing on DSP Burnt in text Unicast Multicast Video Audio Networ Video compression H 264 MJPEG 25 30FPS 1080p PAL NTSC Audio compression G 711 uLaw aLaw PCM Analog video out for external monitors Video motion detection
12. harpness are adjustable through the image settings Setup Video amp Audio Camera 01401 GANZ 9 ZN DN312XE M Installation Guide 9 CONNECTIONS VIDEO DO DI AUDIO 1 1 D Audio input output The camera has a mono audio input and a mono audio output Due to low audio output power an amplified speaker is recommended for enhanced sound Do not connect a headphone or earphone directly to the camera AUDIO Out Amp Speaker Analog video output connection Connect a display device such as a monitor to the video output connector and check if the camera is properly streaming the images 8 Sensor DI connection The camera provides 1 channel D I It can be connected to either a voltage type sensor or a relay type sensor as the following figures Settings can be done through the camera s webpage Input voltage range OVDC minimum to 5VDC maximum Max 50mA Input voltage threshold 1 5V 01401 GANZ 10 ZN DN312XE M Installation Guide Do not exceed the maximum input voltage or relay rate Caution Internal Interna Output of Sensor DI ne Output of Sensor DI FOSSA Relay Type Voltage Type Alarm DO connection Only the relay type is supported Relay Rating Max 24VDC 50mA Do not exceed the maximum relay rating Caution Internal Device Relay Type 01401 GANZ ZN DN312XE M Installation Guid
13. inistrator account case sensitive as below ID root Password pass 4 Click the installation warning message on the view page and click the Install button in the warning message box If the page does not respond after the installation refresh the page N Internet Explorer Security Warning Do you want to install this software Mame Publisher Cap Co E more options While files from the Internet can be useful this file type can potentially harm your computer Only install software from publishers you trust What s the risk 5 Install the setup exe file by clicking the link shown on the main page Please install program setup exe 6 Follow the instructions of the dialog boxes and complete the installation File Download Security Warning Do you want to run or save this file Name setup exe Type Application 293KB From 192 168 208 245 jin se Ces While files from the Internet can be useful this file type can potentially harm your computer If you do not trust the source do not run or save this software What s the risk 01A 01 ZN DN312XE M Installation Guide 7 When the dialog box appears to request user name and password enter the default value for the administrator account case sensitive as below ID root Password pass 8 Refresh the page and check if the live streaming images are successfully displayed on a monitor 6 2 2 View video using IP address
14. n BW 0 001 lux F1 2 AGC Control Auto s 3 0 9 0mm Vari Focal F1 2 Remote Zoom Focus Control One click AF Day amp Night Removal IR Cut Filter Video Compression Format H 264 and MJPEG Selectable per Stream Number of Streams Dual Stream Configurable Resolution Compression FPS Motion Detection 1920x1080 1280x720 800x450 480x270 320x180 25 30fps 1080p Built in Burnt in Text Digital Video stream overlay text Output Analog video output for installation only Audio Input output 1 1 channel Compression Format G 711 Function Digital Input output 1 1 channel RS 485 Not supported Network 10 100 Base T Power over Ethernet PoE Supported TCP IP UDP IP HTTP RTSP RTCP RTP UDP RTP TCP Protocol SNTP mDNS UPnP SMTP SOCK IGMP DHCP FTP DDNS SSL v2 v3 IEEE 802 1X SSH SNMP v2 v3 SD Slot 1 Micro SD slot Micro SD Card is not included 01A 01 ZN DN312XE M Installation Guide Electrical Characteristics Power Source DC 12V PoE IEEE802 3af Class 0 Power Consumption 1100mA Heater On Video Output 1 Vp p 750 Composite Audio Input Linein 1 43Vp p Min 1 35Vp p max 1 49 Vp p 39 KO Audio Output Lineout 46mW Power 16 Q D I Max 50mA 9 5VDC TTL level 4 5V threshold D O Max 500MA 24VAC or 1A 12VDC On state resistance 50 O max continuous Operating Range Operating Temperature DC12V 0 C 50 32
15. temate DNS server Internet Protocol TCP IP Properties e General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically O Use the following IP address 110 173 IP address 192 168 110 179 Subnet mask TR A A Subnet mask 255 255 d 0 Default gateway Use the following DNS server addresses Preferred DNS server Altermate DNS server 6 2 View video on web page By accessing the IP address of the device through a web browser users can view the live streaming images Users also may use the IPAdminTool to access the webpage of streaming images 01A 01 ZN DN312XE M Installation Guide 6 2 1 View video using IPAdmin Tool IPAdminTool automatically scans all of the products including encoders and cameras on the network and displays product s information including product name IP address MAC address firmware information and devices uptime IPAdminTool is provided with SDK at the following SDK path SDK root BIN TOOLS AdminTool To use the IPAdminTool and view the live video on a web page 1 Start IPAdminTool Currently connected devices names and status appear on the list Right click on the desired device and select Web view 3 When the dialog box appears to request user name and password enter the default value for the adm

Download Pdf Manuals

image

Related Search

Related Contents

IceRod CX Cryoablation Needles - Instructions for  NL - G A R A N T I E B E D I N G U N G E N      5 - SEW-Eurodrive  Manual - IndustryIQ  Harbor Freight Tools 10,000 PSI Pneumatic Hydraulic Pressure Pump Product manual  Handbuch - Trio Solar  

Copyright © All rights reserved.
Failed to retrieve file