CN2600 series Dual-LAN Terminal Server User`s Manual v2

image

Contents

1. 1 DCD CS 7 gt B RTS DTR 8 4 DSR RJ45 8 pins to Female DB25 RJ45 Port RJ45 Connector Female DB25 E Male E TAN DB25 ST RS 232 ici Device 8 pins 3 Cable Wiring 3 25 pins DSR 1 20 DTR RIS 2 5 CTS GND Ss 7 GND TxD 4 o o 333 RxD RD 5 lt 2 TxD DCD 66 78 DCD CTS 7 da RIS DTR 8 6 DSR RJ45 8 pins to Male DB25 RJ45 Port E RJ45 Connector Male DB25 Female 7 DB25 RS 232 CN 2600 i Device 8 pins Cable Wiring 25 pins DSR 1 6 DIR RTS 2 4 CTS GND E nend GND DD 4 gt 2 RxD RxD 5 3 3 xD DCD 6 lt 8 DCD 7 5 CTS sl DTR B TUT 20 DSR A 5 CN2600 Series User s Manual Serial Cables RS 422 4 Wire RS 485 RJ45 8 pins to Female DB9 RJ45 Port CN 2600 8 pins TxD TxD RxD RxD GND RJ45 Connector Female DB9 Cable Wiring NOD O1 BB OW N WD Ol RJ45 8 pins to Male DB9 RJ45 Port Device CN 2600 8 pins TxD TxD RxD RxD GND RJ45 Connector Male DB9 Cable Wiring NOD 0 E WO GO NOA RJ45 8 pins to Female DB25 RJ45 Port CN 2600 8 pins TxD TxD RxD RxD GND RJ45 Connector Female DB25 Cable Wiring NOOA OM WN A 6 Pinouts and Cable wiring Male DB9 Device RS 422 4 wire RS 485 9 pins RxD RxD TxD
2. Directly proceed with data transmission no connection required UDP Ethernet VY lt nweneececeee RS 232 422 485 Redundant COM LAN A Ethernet LAN B Data A CN2610 Serial tangi RTU The Redundant COM operation mode can be used to set up a redundant LAN between the serial devices connected to the CN2600 s serial ports and the host computer The redundant structure involves using the CN2600 s two LAN ports to set up two independent LANs that connect the CN2600 to the host computer If either of the two LANs fails the other LAN will continue transmitting packets between the serial devices and the host with the packets passing through the CN2600 In fact one of the biggest advantages of the CN2600 s Redundant COM mode is that the switching time is zero 4 5 CN2600 Series User s Manual Serial Port Operation Modes ATTENTION 1 If either LAN gets disconnected it will take at least 1 minute for the LAN to recover after reconnecting 2 If both LANs get disconnected you will need to re open your application software s COM port for data to transmit properly Dual host Redundant Data Acquisition System DRDAS Primary PC Backup PC LANA LAN B Primary RS 232 422 485 Remote Terminal Unit RTU The DRDAS operation mode provides a highly redundant network structure that takes advantage of the CN2600 s dual LAN ports dual IP addresse
3. A ATTENTION The serial parameters for the each serial port on the CN2600 should match the parameters used by the connected serial device You may need to refer to your serial device s user s manual to determine the appropriate serial communication parameters Baud rate default 115200 bps This field configures the port s baudrate Select one of the standard baudrates from the dropdown box or select Other and then type the desired baudrate in the input box ATTENTION If the port requires a special baudrate that is not listed such as 500000 bps you may can select the Other option and enter the desired baudrate into the text box The CN2600 will automatically calculate the closest supported baudrate The margin for error will be less than 1 7 for all baudrates under 921600 bps Data bits default 8 This field configures the data bits parameter Note If data bits is set to 5 bits stop bits will automatically be set to 2 bits Stop bits default 1 This field configures the stop bits parameter Note If data bits is set to 5 bits stop bits will automatically be set to 1 5 bits Parity default None This field configures the parity parameter Flow control default RTS CTS This field configures the flow control type FIFO default Enable This field enables or disables the 128 byte FIFO buffer The CN2600 provides FIFO buffers for each serial port for both the Tx and Rx signals Note however that you 7 2 CN26
4. E Console Root lt Ie Internet Information Server 7 8 retentd E s Default FTP Site Ep ADIL S 210p neal o d Default Web Site B 7g Administration W T im Default SMTP Sit wg Default NNTP Sit a 7 Microsoft Transaction S 6 Select Service Verify that the RADIUS ports assignments match your configuration Authentication 1645 or 1812 Accounting 1646 or 1813 7 Select Client and then click Add Enter the CN2600 s IP address in the IP address field Enter the CN2600 s RADIUS key in the password field This must match the RADIUS key that you set in the CN2600 console E iTO HG Aulhen uir alon n Hal a Prope AUE ralanti Howaserver U2 00 Info Host table Route table User table Quit 3 Examina7modi ry asyhe server advance configuratisr Se Ng Sa ETT ko menu Enter lect RADIUS server IP 132 168 265 107 RADIUS kay 123 UDP port 1 1645 2 1812 1 Enable RADIUS accounting yes SNHP community name public SNAP trap server IP address Ethernet IP forwarding no Routing protocol None TCP retransmission tineout L SIO data transfer timeout CN2600 Series User s Manual RADIUS Server 8 Click Apply 9 Right click RADIUS in the left information window and select Start You will now see that RADIUS is running Setting up Windows 2000 Hosts 1 Open Start gt Programs gt Administrative Tools gt Routing and Remote Access
5. File COM Mapping View Help mb BG 5 Remove S 6 Wade Setting mg Tea Ti Software Installation Configuration 132 166 534 111 132 166 354 111 132 166 354 111 132 166 354 111 132 166 534 111 132 166 354 111 132 166 354 111 132 166 354 111 961 967 Ponz 9354 9685 Port3 3153 3693 Port4 954 970 Port5 355 971 Porte 956 972 Port 257 2972 Port8 1568 9374 Porta 132 166 354 111 132 166 354 111 132 166 534 111 132 166 34 111 132 166 534 111 132 169 354 111 132 166 354 111 dod 45 Portl U S60 376 Port11 S61 37 Port1 2 962 978 Port 3 S63 579 Port 4 364380 Port 5 S65 29T Port16 otal COM Port 16 To re configure the settings for a particular serial port on the CN2600 select the row corresponding to the desired port and then click the Settings icon z COM Port Setting Port Number 2 Port s are Selected Basic Settings Advanced Settings Serial Parameters Security fw Auto Enumerating COM Number for Selected Ports COM Number COM3 curent inusel 7 Ar a l IZ Enable Redundant COM fF Mapping addiessi 192 168 354 111 EC flapping Paddrees2 17216 0112 7 On the Basic Settings page use the COM Number drop down list to select a COM number to be assigned to the CN2600 serial port that is being configured Select the Auto Enumerating COM Number for Selected Ports option to assign available COM numbers automatically in sequence to
6. 2 Right click Server Local and select Configure and Enable Routing and Remote Access Click Next to continue 3 Select Remote access server and click Next to continue a Routing and Remote Access li MM ll aa bh 25 Routing and Remote Access Server Setup Wizard Common Configurations TOU can select from several common configurations Internet connection server Enable all of the computers on this network to connect to the Internet Remote access server Enable remote computers to dial in to this network 7 Virtual private network YPN server Enable remote computers to connect to this network through the Internet C Network router Enable this network bo communicate with other networks Manually configured server Start the server with default settings Pstart Z Z TS Routing and Remote 4 Ee RHM O 4 Select Set up an advanced remote access server and click Next to continue 2 Routing and Remote Access Mel X In NM ee a CEB X3 Action S Routing and Remote Access Server Setup Wizard Remote Access Server Setup TOU can use a basic configuration or more advanced options to set up this remote ACCESS SEIVEr Select a configuration type based on the complexity of pour network Set up a basic remote access server Select this option to create a standalone server that will have simplified administrative control Setup an advanced remote access server Select this option to create a server
7. Browser Cookie Settings Verify that cookies are enabled for your browser If the cookies are disabled you will not be able to use the web console Cookies are only used for password transmission 1 For Internet Explorer enable cookies by selecting Internet Options from the Tools menu General Security Privacy Content Connections Programs Advanced m Home page I You can change which page to use for your home page Address nfisapifredir dil prd ie amp pver 6 amp ar msnhome Use Current Use Default Use Blank Temporary Internet files al Pages you view on the Internet are stored in a special folder for quick viewing later Delete Cookies Delete Files Settings m History A The Histon folder contains links to pages you ve visited for quick access to recently viewed pages Days to keep pages in history 20 Clear History fa Colors Fonts Languages Accessibility Cancel Apply 2 Select the Privacy tab There are six levels of privacy setting Block All Cookies High Medium High Medium Low and Accept All Cookies Users must select Medium High as the image shows or below to access the CN2600 web console General Security Privacy Content Connections Programs Advanced M Settings c Move the slider to select a privacy setting for the Internet Tell zone Medium High B
8. BC Port 4 Link quality report O Enable Disable a Port 5 Outgoing PAP ID aE Port 6 PAP password F T j i ES Incoming PAP check None LY Ports 7 dig Disconnect by None CJ Welcome Message F S P1 Ipa OPa CIP4 Ces CIP6 COP ips ao System Management Apply the above settings to H System Monitoring all ports Save Configuration HE Restart Submit Emt lt gt PPPD PPP on demand is used for dial in services since it provides PPP services only when receiving a request from a remote PC Destination IP address This is the IP address of the remote dial in dial out server Source IP address The Source IP address is IP address assigned to this serial port 6 25 CN2600 Series User s Manual Configuring Serial Port Operation Modes IP netmask The IP netmask defines the netmask also known as the subnet mask for the PPP connection TCP IP compression default No The setting of this field depends on whether the remote user s application requests compression Inactivity time default 0 ms This field specifies the idle time setting for auto disconnection A setting of O ms will cause the port to remain connected even if idle Link quality report default No Setting this field to Yes allows the CN2600 to disconnect a connection if the link noise exceeds a certain threshold Outgoing PAP ID This is the dial out user ID account PAP password This is the dial out user password Incoming PA
9. HS Restart w gt Submit NG Destination address 1 through 4 default None In UDP mode you may specify up to 4 ranges of IP addresses for the serial port to connect to At least one destination range must be provided ATTENTION The maximum selectable IP address range 1s 64 addresses However when using multi unicast you may enter IP addresses of the form xxx xxx xxx 255 in the Begin field For example enter 192 127 168 255 to allow the CN2600 to broadcast UDP packets to all hosts with IP addresses between 192 127 168 1 and 192 127 168 254 Local listen port default 4001 This is the UDP port that the CN2600 listens to and that other devices must use to contact the CN2600 To avoid conflicts with well known UDP ports the default is set to 4001 6 12 CN2600 Series User s Manual Configuring Serial Port Operation Modes A Packet length default 0 The Packet length setting refers to the maximum amount of data that is allowed to accumulate in the serial port buffer before sending At the default of 0 for packet length no maximum amount is specified and data in the buffer will be sent as specified by the delimiter settings or when the buffer is full When a packet length between 1 and 1024 bytes is specified data in the buffer will be sent as soon it reaches the specified length Delimiter 1 and Delimiter 2 default None When Delimiter 1 is enabled the serial port will clear the buffer and send the data to the
10. mocha a a Remove Apply Undo Setting COM Port 7 IF Address 1 IP Address 2 9 10 CN2600 Series User s Manual Software Installation Configuration 3 Click Rescan to search for CN2600 terminal servers From the list that is generated select the server that COM ports will be mapped to and then click OK ladd NPort Mi Rinas 19216834219 00 90 E8 10 51 68 192 168 386 219 Happing Redundant Ca Por IP Addjeis 2 det ata Pali Jak Command Bot Tatal Ports Alternatively you can select Input Manually and then manually enter the CN2600 s IP Address 1st Data Port 1st Command Port and Total Ports for the COM ports that will be mapped to Click OK to proceed to the next step Note that the Add NPort page supports FQDN Fully Qualified Domain Name in which case the IP address will be filled in automatically Add NPort 9 11 CN2600 Series User s Manual Software Installation Configuration 4 COM ports and their mappings will appear in blue until they are activated Activating the COM ports saves the information in the host system registry and makes the COM port available for use The host computer will not be able to use the COM ports until the COM ports are activated Click Yes to activate the COM ports at this time or click No to activate the COM ports later E aja Dm g Evit Add Hemove Undo EIH m COM18 A 1689 34 19 950 966 Port1 2 COM 9 192 168 534 419 951 967
11. B system Status fa Network Canne Sr Network Statis A Serial Data Loc Select all Clear log Refresh Routing Go to Routing under System Status to display the routing information mp Total Solution for Industrial Device Networking nG oc 7 Routing Bd Pot Fr Port 8 Current Routing er Port 3 Iface Destination Gateway HA Netmask Metric Flag Use TIS ptni 192 168 127 0 192 168 127 254 255 255 255 0 1 U 361 BG Port 12 GD Port 13 Y Port 14 TO Port 15 Gi Welcome Messag SIS System Managemer ny System Monitoring ef Serial Status 24 System Status L I Network Conne Gg Network Statis E Serial Data Loc Routing AI Dout State 8 18 CN2600 Series User s Manual System Management Settings Save Configuration Go to Save Configuration and then click Save to save the your submitted configuration changes to the CN2600 s flash memory The configuration changes will then be effective when the CN2600 is restarted If you do not save your changes before restarting they will be discarded Total Solution for Industrial Device Networking OI Main Menu r Save Configuration CI Overview R Basic Settings If you have submitted any configuration changes you must save the changes and restart KC aier they taka face Giek Sava to zaye the changes fn the NPore cooo Serial Port Settings SI System Management ao Misc Rd S gers i a Auto Warning Settings ae Mainte
12. CJ Overview a Basic Settings No Gateway Destination Netmask Metric Iface HQ Network Settings 2 it n C HE Serial Port Settings 1 203 67 56 254 3 kaiba 285 255 255 255 2 amg K ag System Management 1 lani M i ST Misc Network Settings 3 zm lani a Accessible IP List 4 pi lani i ks ae ae 5 a lant 8 8 Dons C CO Host Table 1 lani CJ Route Table 7 l E J ant Ga User Table 8 Ka a i i lani CJ Authentication Serve 9 fe lani i CJ System Log Settings 10 HA lani 9 eE Auto Warning Settings sa Fi Pwe S CJ Maintenance zz pam z T a ee BG Certificate He 7 S L r SIS System Monitoring 13 1 lani 7 CJ Save Configuration 14 Lop a lani M HE Restart 15 1 lani Y 16 1 lani 2 lt l 17 ii lani v Configuring Multiple Point Routes Web FTP E mail News s Server Server Ethernet 203 67 6 TCP IP 203 67 6 253 E Ces NP ort 6000 Gg Pouter 1 203 67 6 254 RS 232 RS 232 Modem 1 lt gt lt gt Modem 2 Internet Modem 3 ng s Modem 4 RS 232 RS 232 202 6 6 254 _ NPort 6000 201 2 2 254 _NPort 6000 pa 1 11 Series I Series as S Printer pa f MRP Printer pa MRP M Server 6 Server gt S 7 202 6 6 3 gt 7 201 2 2 1 Phone
13. File Edit View Favorites Tools Help 5 x Back O r x B A SI Search ST Favorites o LS E 2 Address http jji9z 168 127 2547 ED Total Solution for Industrial Device Networking E Main Menu E mail Alert CJ Overview R Basic Settings ae Network Settings ae Serial Port Settings Ag System Management ae Misc Network Settings oo Auto Warning Settings L Event Settings R Serial Event Settings N E mail Alert Mail Server Settings Mail server SMTP V My server requires authentication User name Password From e mail address To e mail address 1 C9 SNMP Trap ae Maintenance X Certificate SIE System Monitoring RL Save Configuration H Restart To e mail address 2 To e mail address 3 To e mail address 4 The E mail Alert settings configure how e mail warnings are sent for system and serial port events You may configure up to 4 e mail addresses to receive automatic warnings ATTENTION Consult your Network Administrator or ISP for the proper mall server settings The Auto warning function may not work properly if it is not configured correctly The CN2600 s SMTP AUTH supports LOGIN PLAIN and CRAM MD5S RFC 2554 Mail server This field is for your mail server s domain name or IP address User name This field is for your mail server s user name if required Password This field is for your mail server s password if required
14. Sees File Function View Help F e a pa ET E Exit SearchIP Ban da IP UntLocl Ipgrade No 7 Model MAC Address1 IP Address MAC Address2 IP Address2 Status O Search Result 0 fs The Searching window indicates the progress of the search Searching Searching for NPort Found 1 NPort s 5 second s left MAC Address IP Address1 MAC Address2 IP Address2 CN2610 16 00 90 E8 0E F4 0E 192 168 32 65 00 90 E8 0E F4 0F 192 168 34 65 9 5 CN2600 Series User s Manual Software Installation Configuration 2 When the search is complete all CN2600 servers that were located will be displayed in the NPort Search Utility window LO NPort Search Utility SEE File Function View Help F 2 C3 B E Exit Search Search IP No 7 Model MAC Address1 IP Address MAC Address2 IP Address2 1 CN2610 16 O0 90 E8 0E F4 0E 192 168 32 65 00 90 E8 0E F4 0F 192 168 34 65 To modify the configuration of the highlighted CN2600 click on the Console icon to open the web console This will take you to the web console where you can make all configuration changes Please refer to Chapter 5 Configuration with the Web Console for information on how to use the web console LOR NPort Search Utility File Function View Help P 2 4 x rf Exit Search Search IP Console Assign IP Upgrade No 7 Model MAC Address1 IP Address1 MAC Address2 IP Address2 CN2610 16 00 90 E8 0E F4 0E 192 168
15. Terminal BIN mode allows one session per port and is used for terminal applications that include file transfer features 4 8 CN2600 Series User s Manual Serial Port Operation Modes Reverse Terminal Applications Unix Windows NT jouja Go Router Server Server Reverse terminal applications are similar to terminal applications in that they involve using the CN2600 to manage the connection between a terminal and a server The difference is that with reverse terminal applications the terminal is connected through the network and the server is connected through the serial port rather than the other way around In practice a reverse terminal session typically involves a network administrator telnetting to a device that has a dedicated serial console port used specifically for configuration purposes For example many routers switches UPS units and other devices including the CN2600 have Console AUX or COM ports to which a terminal can be physically connected for console management With the CN2600 the device s console port can be connected to a serial port on the CN2600 allowing a network administrator to telnet to the device remotely through the network Although modern network equipment generally allows other options for remote configuration through the network there are situations in which it is necessary or desirable to configure a device by serial console e g for security reasons when using
16. auto detecting 10 100 Mbps Ethernet e 8 MB RAM 16 MB Flash ROM e Tx Rx LEDs for each serial port e System Status LEDs e Ethernet Status LEDs e 8 or 16 RJ45 RS 232 serial ports with up to 921 6 Kbps transmission speed e 2 KV Serial Line Protection for isolation models Software e ASCII Binary terminal modes with up to 8 Telnet and Rlogin sessions e Point to Point Protocol PPP and PPPD e Serial Line Internet Protocols SLIP and SLIPD e Dynamic auto recognition of Terminal SLIP or PPP e Dial on demand Dial out e CN2600 series Terminal Server Proprietary Protocol ASPP for TCP IP socket programming e RAW mode for transparent data transmission e Reverse Telnet e SNMP Agent for network management e Network protocols TCP IP UDP ICMP NetBEUI DHCP e Application protocols Telnet Rlogin Rtelnet RAW TCP RAW UDP WINS DRDAS DNS Multi Host e Security protocols RADIUS Dial back PAP CHAP Local user password e Real COM port drivers Windows 95 98 ME NT 2000 Windows XP 2003 Vista 2008 7 x86 x64 e Real TTY drivers Linux kernel 2 4 x 2 6 x e Fixed TTY Drivers SCO Unix SCO OpenServer UnixWare 7 UnixWare 2 1 SVR 4 2 QNX 4 25 QNX 6 Solaris 10 FreeBSD AIX 5 x e Static Routing RIP I II protocols e Windows like administrative CONSOLE utility from a fixed console port or by Telnet from a networked host e Password protection and extensive user verification functions e Easy firmware upgr
17. data transmission proceeds as follows The host requests a connection from the CN2600 which is configured for TCP Server mode Once the connection is established data can be transmitted in both directions between the host and the CN2600 TCP Client Mode In TCP Client mode the CN2600 can actively establish a TCP connection to a pre defined host computer when serial data arrives After the data has been transferred the CN2600 can automatically disconnect from the host computer by using the Inactivity time settings As illustrated in the figure data transmission proceeds as follows The CN2600 configured for TCP Client mode requests a connection from the host Once the connection is established data can be transmitted in both directions between the host and the CN2600 Serial Port Operation Modes ee T HeRR Ethernet TCP Server xo abang Request a connection RS 232 422 485 Proceed with data transmission O Request a connection Proceed with data transmission RS 232 422 485 CN2600 Series User s Manual Serial Port Operation Modes UDP Mode Compared to TCP communication UDP is faster and more efficient In UDP mode you can unicast or multi unicast data from a serial device to one or multiple host computers and the serial device can receive data from one or multiple host computers These traits make UDP mode especially suited for message display applications
18. prs Examine modify the ethernet LAN port settings Enter select ESC previous Menu State PEN EA EA PE Ready 3 11 4 Serial Port Operation Modes In this chapter we describe the various operation modes of the CN2600 CN2600 modes are grouped by type of application such as Device Control or Reverse Terminal The options include an operation mode that relies on a driver installed on the host computer and operation modes that rely on TCP IP socket programming concepts After selecting the proper operation mode please refer to Chapter 5 Configuration with the Web Console for detailed information on configuration parameters The following topics are covered in this chapter E E G E O Overview Device Control Applications gt Real COM Mode gt RFC2217 Mode Socket Applications gt TCP Server Mode gt TCP Client Mode gt UDP Mode Redundant COM Dual host Redundant Data Acquisition System DRDAS Terminal Applications gt Terminal ASCII Mode gt Terminal BIN Mode Reverse Terminal Applications gt Reverse Telnet Dial In Out Modes Disabled Mode CN2600 Series User s Manual Serial Port Operation Modes Overview The CN2600 network enables traditional serial RS 232 422 485 devices The serial device server is a special purpose computer equipped with a CPU and TCP IP protocols that can bi directionally translate data between the serial and Ethernet formats Your own computer will be able to access manage and con
19. 3 L SE HTTP console Enable Disable A Network Setti A ore ges HTIPS console amp Enable Disable HE Serial Port Settings TERA PTEE Telnet console Enable Disable oc System Management E 2 Le a X 55H console i OC Misc Network Settings SHS pisaba a Auto aming setings Reset button Always Enable Disable after 60 sec sa Maintenance LCM read only protection writable Read only Cl Console Settings an Submit 1 Firmware Upgrade a Configuration Import On this screen access to different CN2600 configuration console options HTTP HTTPS Telnet SSH can be enabled or disabled The CN2600 front panel known as the LCM Liquid Crystal Module may be configured for read only or writeable access In other words you can use the front panel to check console settings only read only access or to actually make changes to the settings writeable access Note that if the console is password protected and LCM is configured 8 10 CN2600 Series User s Manual System Management Settings for writeable access you will need to enter the password to submit any console setting changes Please refer to Change Password later in this chapter for more information on passwords Finally you may also enable or disable the reset button 3 NPort Web Console Microsoft Internet Explorer File Edit view Favorites Tools Help I Q 83k g D B fi pa Search 5 2 Favorites Dog Bl Ss Address http 192 1
20. 32 65 00 90 E8 0E F4 0F 192 168 34 65 I Search Result 1 NPort s 9 6 CN2600 Series User s Manual Software Installation Configuration Windows Driver Manager Installing NPort Windows Driver Manager The NPort Windows Driver Manager can be used with CN2600 serial ports that are set to Real COM mode The Driver Manager manages the installation of drivers which allow you to map unused COM parts on your PC to serial ports on the CN2600 These drivers are designed for use with Windows 95 98 ME NT 2000 XP 2003 Vista When the drivers are installed and configured devices that are attached to serial ports on the CN2600 will be treated as if they were attached to your PC s own COM ports If you are using the older version named Async Server Windows 2000 XP 2003 driver please refer to Chapter 9 Setting up Hosts for installation information Note that you may also download the latest Windows Driver Manager from Moxa s website 1 Click the INSTALL COM Driver button in the CN2600 Installation CD auto run window to install NPort Windows Driver Manager Once the installation program starts running click Yes to proceed 2 Click Next when the Welcome screen opens to proceed with the installation iG Setup NPort Windows Driver Manager Blei Welcome to the NPort Windows Driver Manager Setup Wizard This will install NPort Windows Driver Manager Ver1 2 on your computer tis recommended that you close all other applicati
21. Auto You may configure the network speed for the built in Ethernet connection on the CN2600 IEEE802 3 Ethernet supports auto negotiation of transfer speed However some switches hubs require that the communication speed be fixed at 100Mbps or 10Mbps Advanced Network Settings You can access Advanced Network Settings by expanding the Network Settings item in the navigation panel Advanced Network Settings is where the routing protocol and gratuitous ARP are configured E Main Menu ia r Network Settings Advanced CJ Overview CJ Basic Settings AE Network Settings CJ Basic Network Settings Oj Advanced Network Set OC Serial Port Settings H System Management HE System Monitoring Routing protocol None Gratuitous ARP Enabled Send period 10 1000 sec 4 Save Configuration HQ Restart What is RIP RIP Routing Information Protocol is a protocol used to manage routing information within a self contained network such as a corporate LAN Local Area Network or an interconnected group of such LANS By using RIP a gateway host with a router can send its entire routing table which lists all the other hosts it knows about to its closest neighbor host every 30 seconds The neighbor host in turn will pass this information on to its closest neighbor and so on until all hosts within the network have the same routing path information This state 1s known as network convergence RIP uses a hop count as a way of d
22. CN2600 Series User s Manual Configuration with the Web Console The CN2600 will play the role of a DNS client in the sense that it will actively query the DNS server for the IP address associated with a particular domain name The following functions on the CN2600 web console support the use of domain names in place of IP addresses Time Server Destination IP Address in TCP Client mode Mail Server SNMP Trap Server Destination Address in Pair Connection mode Primary Secondary Host Address in Terminal mode RADIUS Server and SMTP Server DNS server 2 This is an optional field The IP address of another DNS server may be entered in this field for times when DNS server 1 is unavailable PPPoE user account and PPPoE password For dynamic broadband networks such as xDSL or cable modem users must enter the username and password that they received from their ISP to establish network connection If a serial port on the CN2600 will be using PPPoE enter the account name and password in these fields WINS function default enable Enable or disable the WINS Windows Internet Naming Service server WINS server If a WINS Server is connected to the network enter the WINS Server s IP address in this field TCP IP uses IP addresses to identify hosts but users often use symbolic names such as computer names The WINS Server which uses NetBIOS over TCP IP contains a dynamic database to map computer names to IP addresses LAN speed default
23. CN2600 uses jumper settings or DIP switches to set the pull high low resistor values for each serial port To set the pull high low resistors to 150 KQ make sure both of the assigned DIP switches are in the OFF position This is the default setting To set the pull high low resistors to 1 KQ make sure both of the assigned DIP switches are in the ON position A ATTENTION Do not use the 1 KO setting on the CN2610 when using the RS 232 interface Doing so will degrade the RS 232 signals and shorten the maximum allowed communication distance 2 4 3 Initial IP Address Configuration When setting up the CN2600 for the first time the first thing you should do is configure its IP address This chapter introduces the different methods that can be used Please refer to Chapter 8 System Management Settings for more details about network settings The following topics are covered in this chapter LJ Static and Dynamic IP Addresses Q Factory Default IP Address LI Configuration Options gt Terminal Server Search Utility Web Console LCM Console Front Panel ARP Telnet Console VV VV Y Serial Console CN2600 Series User s Manual Initial IP Address Configuration Static and Dynamic IP Addresses Determine whether your CN2600 needs to use a static IP or dynamic IP address either DHCP or BOOTP PPPoE application e If your CN2600 terminal server is used in a static IP environment you will assign a specific IP address using on
24. Config Import Config Export OpMode Connect Disconnect Authentication Fail Restart Auto Warning Settings Event Settings SI Main Menu Event Settings LI Overview S CI Basic Settings l System Event HAI Network Settings CJ Serial Port Settings Rea Star Cl Mail OTrap AS System Management varm Start C mail C Trap 8G Misc Network Settings Power 1 down C mail BG Auto Warning Settings Power 2 down C mail O Event Settings Network Event 3 5 CI Serial Event Setting Ethernet 1 link down C mail OTrap CJ E mail Alert Ethernet 2 link down TMa Otrap K H Itay Config Event i Ra AZV adla Console web text login auth fail C Mail O Trap BJ Certificate fiand ANA HE System Monitoring a Save Configuration Password changed C mail HE Restart On the Event Settings page you may configure how administrators are notified of certain system network and configuration events Depending on the event different options for automatic notification are available as shown above Mail refers to sending an e mail to a specified address Trap refers to sending an SNMP Trap Cold start This refers to starting the system from a power off state or after upgrading your firmware Warm start This refers to restarting the CN2600 without turning the power off Power down Power and Power refer to the built in power jacks If either power fails the CN2600 will attempt to send an e mail warning Network Event Etherne
25. D CJ Serial Port Status 6 o 0 o o C9 Serial Port Error CoL Z 2 i a p Serial Port Settings Go to Serial Port Settings under Serial Status to view a summary of the settings for each serial port 2 Total Solution for industrial Device Networking J Main Menu x ao 4 Serial Port Settings i yerview O Basic Settings Ml Auto refresh ALI Network Settings Flow Control o G2 Serial Port Settings Port Baud Rate Data Bits Stop Bits Parity RTS CTS XON XOFF DTR DSR FIFO Interface Giga System Management 1 115200 8 1 None ON OFF OFF Enable RS 232 Bey TO 2 115200 8 1 None ON OFF OFF Enable RS 232 PANGA TANA 3 115200 8 1 None ON OFF OFF Enable RS 232 ES Serial Status 4 115200 8 1 None ON OFF OFF Enable RS 232 CJ Serialto Network Ce 5 115200 8 1 None ON OFF OFF Enable RS 232 C9 Serial Port status 6 115200 8 1 None ON OFF OFF Enable RS 232 Gg SeriaiPortErrorca 7 115200 8 1 None ON OFF OFF Enable RS 232 i 8 115200 8 1 None ON OFF OFF Enable RS 232 1 E Serial Port Settings R System Status Network Connections Go to Network Connections under System Status to view network connection information wo Total Solution for Industrial Device Networking 1 CI Port Network Connections Port 7 H Port 8 Protocol Recy Q Send Q Local Address Foreign Address State G Porto TCR 0 O 192 168 127 254 9000 LISTEN B port 10 TCP o 0 192168 127 254 4900 LISTEN TCP 0 0 192 168 127 254 14900 LISTEN i
26. Desktop Place your CN2600 on a clean flat well ventilated desktop For better ventilation attach the 4 pads from the desktop kit to the bottom of the unit and leave some space between the CN2600 and other equipment Do not place equipment or objects on top of the unit as this might damage the Server ad Bottom of CN261 Pads Rackmount The CN2600 is designed to be mounted on a standard 19 inch rack Use the enclosed pair of L shaped metal brackets and screws to fasten your CN2600 to the rack cabinet Each L shaped bracket has 6 holes leaving two outer or inner holes available for other uses You have two options You can lock either the front or rear panel of the CN2600 to the front of the rack Locking the front panel is shown in the following figure L Shaped Metal Bracket SI o p J O o a f S k JL SL JL JL J JL JL 4 NG Rackmount rail N ad Wiring Requirements ATTENTION Safety First Be sure to disconnect the power cord before installing and or wiring your CN2600 Wiring Caution Calculate the maximum possible current in each power wire and common wire Observe all electrical codes dictating the maximum current allowable for each wire size If the current goes above the maximum ratings the wiring could overheat causing serious damage to your equipment Temperature Caution Be careful when handling the CN2600 When plugged in the CN2600 s internal components generate hea
27. Operation Modes Redundant COM E Main Menu a O Overview 0 Basic Settings Operation Modes Port 1 H Network Settings r vx L l 7 A ati Redundant COM w EN Serial Port Settings BUTTER i Bey Port 1 Max connection 1 ae CJ Operation Modes Ignore jammed IP Enable Disable Gg Communication P Allow driver control Enable Disable G3 Data Buffering Lo Connection goes down RTS O always low always high J Modem Settings DTR O always low always high le Port 2 Data Packing BE Port 3 Packet length 0 0 1024 BI Port 4 Ea Delimiter 1 00 Hex C Enable BO Ports BE port 6 Delimiter 2 00 Hex C Enable i Boy Port Delimiter process Do Nothing Processed only when Packing length is 0 BJ Ports Force transmit 0 0 65535 ms Wa boMG Messana PAPA AK Pt Ore Ops Mres Ors Ore mp Ops ar pply the above settings to System Management Pall ports HI System Monitoring CJ Save Configuration Fi Restart M lt gt Max connection default 1 This field is used if you need to receive data from different hosts simultaneously When set to 1 only one specific host can access this port of the CN2600 and the Redundant COM driver on that host will have full control over the port When set to 2 or greater up to the specified number of hosts Redundant COM drivers may open this port at the same time When multiple hosts Redundant COM drivers open the port at the same time the COM
28. Port 1 Application Mode TERM_BIN mode PPPD mode SLIPD mode Authentication type Apply the above settings to Total Solution for Industrial Device Networking Dial in out i Dynamic gt Enable O Disable Enable O Disable Enable Disable None Pi P2 p3 1p4 Ops Ps 17 OPs O All ports Dynamic mode integrates PPPD SLIPD and Terminal dial in services Dynamic mode automatically detects which remote connection mode is being used and provides corresponding services You can individually enable disable PPP SLIP Terminal services by selecting Yes or No next to the corresponding option Yes will enable that type of service No will disable it Authentication type default None This field allows you to configure the method used if any to verify a user s ID and authorization Verify the ID against the CN2600 User Table Verify the ID against the external RADIUS server Authentication is not required Disabled Mode Main Menu A Overview a G Basic Settings HE Network Settings ay Serial Port Settings EXSY Port 1 Cl Operation Modes CJ Communication P CJ Data Buffering Lo CJ Modem Settings ao Port 2 959 Port3 ag Port 4 S Ports YG Ports WS part 2 YG Pots J Welcome Message ao System Management a System Monitoring a Save Configuration E Restart a Operation Modes Port 1 Application Disable 1 gt Tot
29. TxD GND Female DB9 RS 422 4 wire RS 485 9 pins RxD RxD TxD TxD GND Male DB25 RS 422 4 wire RS 485 Device 25 pins RxD RxD TxD TxD GND CN2600 Series User s Manual RJ45 8 pins to Male DB25 RJ45 Port CN 2600 8 pins TxD TxD RxD RxD GND Serial Cables 2 Wire RS 485 RJ45 8 pins to Female DB9 RJ45 Port 8 pins Data Data GND RJ45 Connector Male DB25 Cable Wiring 2 4 4 E 2 D 6 8 5 6 3 G o RJ45 Connector Female DB9 RJ45 8 pins to Male DB9 RJ45 Port CN 2600 8 pins Data Data GND Cable Wiring 5 3 6 1 3 5 RJ45 Connector Male DB9 Cable Wiring 5 6 3 RJ45 8 pins to Female DB25 RJ45 Port CN 2600 8 pins Data Data GND E RJ45 Connector Female DB25 Cable Wiring A 7 Pinouts and Cable wiring 7 Female DB25 RS 422 4 wire RS 485 Device 25 pins RxD RxD TxD TxD GND Male DB9 CN 2600 2 wire RS 485 Device 9 pins Data Data GND Female DB9 2 wire RS 485 Device 9 pins Data Data GND Male l DB25 2 wire RS 485 Device 25 pins Data Data GND CN2600 Series User s Manual RJ45 8 pins to Male DB25 Pinouts and Cable wiring RJ45 Port l RJ45 Connector Male DB25 Female f DB25 3 2 wire RS
30. Windows NT Explorer A Find Administrative Tools Common z LE HyperSnap DX lan K Hel en SANTA CAN AIKO ad E nternet Connection Services for RAS gt Run fi Internet Service Man ager ES Microsoft Internet Information Server gt fc Microsoft NNTP Service E S Microsoft Transaction Server fo Microsoft SMTP Service E Product Documentation Intemet Service Manager HTML Release Notes 3 Windows NT 4 0 Option Pack Setup amp Log Off Administrator kap Shut Down Windows NT Server Go to Console Root gt Internet Information Server in the left pane Your computer s name should be visible Find your computer s name in the left panel and click on it after which you will see RADIUS in the right information window Si Microsoft Management Console iis Console Root Intemret Information Server rats mE E t r Console Window Help laj EE 3 7 Action 7 View es o Bs a KS MI DU Ap Nama T 7 1 Console Root E Intemet nformeation Server 9 Defaut ven Site T d Adminiatabton Wab Site ea Default SMTP Site Z Default NNTP Site H E MicrosoH Transaction Server Done A E 4 CN2600 Series User s Manual RADIUS Server 5 Right click RADIUS in the left information window and then select Properties ir Microsoft Management Console iis Console Root Internet Information Server rats Piel KI A19 x
31. browser Please refer to Chapter 5 Configuraton with the Web console for details on how to access and use the CN2600 web console LCM Console Front Panel The CN2600 only gives you the option to configure some settings through the front panel also known as the LCM Liquid Crystal Module console The LCM console can be configured for read only or writeable access Read only access allows settings to be viewed but not changed Factory default settings are for writeable access where configuration is allowed through the LCM console NOTE The wide temperature model does not have an LCM Display panel and push buttons The LCM description below applies only to standard temperature models 3 2 CN2600 Series User s Manual A ARP Initial IP Address Configuration ATTENTION If a password has been enabled for the CN2600 console and the LCM console is configured for writeable status the LCM console will require you to enter the password before allowing you access The password will not be required if the LCM console is configured for read only access The MENU button activates the main menu It is also used to cancel a selection and return to a previous menu The UP and DOWN buttons navigate between available options The SEL button confirms a selection or enters a submenu The IP environment Static DHCP PPPoE etc is configured under Main Menu gt Network setting gt IP config The IP address is configured under Main Men
32. cm lani 9 i E 6 F fi dt lani Y CJ Host Table r r C2 Route Table 7 kaa Laro x 4 User Table 8 it lani X z CJ Authentication Serve 9 E lani i System Log Settings 40 fe ani M ae Auto Warning Settings 14 Fi ani a AJ Maintenance S pa x T L T ma HO Certificate sp Coe af System Monitoring 13 1 lanl N fa Save Configuration a L H it lanl HE Restart 15 1 lani 16 t lani 7 2 G fe lant Generally connections to the Internet are handled by assigning a gateway server in the network settings rather than through the route table Configuring Routes to the Intranet 203 67 6 1 UNIX Server Ethernet 203 67 6 TCP IP 203 67 6 252 E P4 Router Lee B 203 67 6 253 NPort 6000 A Router Series 203 67 6 254 guia Ramer E O E Ethernet SS g 202 65 66 Internet 5 O O Notebook In this example dial in users can make requests to Intranet hosts 202 65 66 4 or 202 65 66 5 which are on network 202 65 66 xxx located outside network 203 67 6 xxx You will need to add a route entry for the next hop router 203 67 6 252 that delivers requests to network 202 65 66 xxx The metric hop in this case is 2 route hops 5 12 CN2600 Series User s Manual Configuration with the Web Console gt Total Solution for Industrial Device Networking SI Main Menu Route Table
33. command init q or reboot your UNIX operating system Adding an additional server 1 Modify the text file moxattyd cf to add an additional server The user can use vi or any text editor to modify the file For more configuration information look at the file moxattyd cf which contains detailed descriptions of the various configuration parameters 2 Find the process ID PID of the program moxattyd ps ef grep moxattyd 3 Update configuration of moxattyd program kill USR1 PID e g if moxattyd PID 404 kill USR1 404 This completes the process of adding an additional server 9 25 Pinouts and Cable This appendix covers the following topics LJ Port Pinout Diagrams gt gt gt gt RS 232 422 485 Male DB9 Pinouts RS 232 Male DB9 Pinouts RS 232 Male RJ45 Pinouts RS 232 422 485 Male RJ45 Pinouts Q Cable Wiring Diagrams gt VV Y Y Ethernet Cables Serial Cables RS 232 Serial Cables RS 422 4 Wire RS 485 Serial Cables 2 Wire RS 485 Pin Assignments for DB9 and DB25 Connectors CN2600 Series User s Manual Port Pinout Diagrams RS 232 422 485 Male DB9 Pinouts 12345 6789 RS 422 PIN RS 232 RS 485 4W 1 DCD TxD A 2 RXD TxD B 3 TXD RxD B 4 DTR RxD A 5 GND GND 6 DSR 7 RTS 3 CTS pi 9 maa YAN RS 232 Male DB9 Pinouts 12345 Pinouts and Cable wiring RS 485 2W Data B Data A GND CN2600 Series User s Manual Pinouts and Cable wir
34. commands will be accepted with the most recent command received taking precedence 6 3 CN2600 Series User s Manual Configuring Serial Port Operation Modes A Connection goes down default always high You can configure what happens to the RTS and DTR signals when the Ethernet connection goes down For some applications serial devices need to know the Ethernet link status through RTS or DTR signals sent through the serial port Use goes low if you want the RTS and DTR signal to change their state to low when the Ethernet connection goes down Use always high if you do not want the Ethernet connection status to affect the RTS or DTR signals Packet length default 0 The Packet length setting refers to the maximum amount of data that 1s allowed to accumulate in the serial port buffer before sending At the default of 0 for packet length no maximum amount is specified and data in the buffer will be sent as specified by the delimiter settings or when the buffer is full When a packet length between 1 and 1024 bytes is specified data in the buffer will be sent as soon it reaches the specified length Delimiter 1 and Delimiter 2 default None When Delimiter 1 is enabled the serial port will clear the buffer and send the data to the Ethernet port when a specific character entered in hex format is received A second delimiter character may be enabled and specified in the Delimiter 2 field so that both characters act as the delimiter to co
35. for ansi vt100 and press ENTER to continue cm Telnet 192 169 0 102 Terminal Server CN2658 8 2AC Console terminal type C1 ansi vtifW 2 ut52 1 3 5 CN2600 Series User s Manual Initial IP Address Configuration 3 Press N or use the arrow keys to select Network and then press ENTER E ee CN2656 8 2AC_ 1 6 Overview Basic TL Ne C uor k IEE Port System Monitor sAve Restart Exit Examine modify the ethernet LAN port settings Enter select ESC previous menu 4 Press B or use the arrow keys to select Basic and then press ENTER 0 x CN2650 8 2AC 6 1 0 Advanced Quit Examine modify basic network settings Enter select ESC previous menu CN2600 Series User s Manual 5 Use the arrow keys to move the cursor to IP address Use the DELETE BACKSPACE or SPACE keys to erase the current IP address and then type in the new IP address and press ENTER Note that if you are using a dynamic IP configuration BOOTP SHCP etc you will Initial IP Address Configuration need to go to the IP configuration field and press ENTER to select the appropriate configuration N2650 8 2AC Advanced Quit CN2Z658 8 2AC_ 8 1 8 BEE al Examine modify basic network settings ESC back to menu Enter select LAMI IP configuration LAMI IP address LANI Netmask LANI Gateway LAMI speed LAMI PPPoE user account LAN1 PPPoE password LANZ IP conf
36. haaa nabaha 5 10 Configuring Serial Port Operation Modes sss ssssssssssssesessssssssss vesse sss 6 1 Port Seo B aE eaa a 6 2 Device CONTOLAPPIICANON a daa ANAN AA AA 6 3 RECOM AY KA AA 6 3 REC2217 MOG naa AANI DAANAN 6 5 SOCKELAPP GATONG AA AA AA AA GAGANA 6 7 HRE BAN Lea T 6 7 GPC AIN PAA 6 9 UDP MOT AA ANAN NAA AA ANAN 6 12 Redundant COM ANAKAN nea eee antes Adela eer Sree tea nla Suen aides Aa dala oer Seacrest 6 14 TRIAS aNG NONA ALALA ATON ANAN NANANA 6 16 PRDAS Real COM aaa aaa nG ER nearer on nti en an a A 6 16 DRDAS TEP Ser Ver am ANAN GANTI a a 6 18 Terminal Appl CaO ns ai ana ANA AGA aaa ana 6 20 erin AS CU TERM ASO mana aNG 6 20 Terminal BIN TERM BIN maana aangal 6 22 Reverse E e TH PTT 6 23 Dial lIVOUCAPP eT 6 24 PPP NOJ Na 6 24 PPD NOG A na cesinaneens dacina ges eenecinek oe Sua ot oodles saueecestenctien sect asaces 6 25 SLIP MOUNT NAAN AA 6 26 SCIPO MONA mana 6 27 Dami Mode namna a AN NAA AA 6 28 Pisabled MOD aaa a ANA AA aNG 6 28 Additional Serial Port SettingS cccccsssseecssesseeeecenseeeseesseeeseeeneensees 7 1 POL COMMUNICAL ON Te L T 7 2 S15 ON MN T AN NBP 7 2 Port Data Bui erie T 7 3 P r GL AA 7 3 Welcome MESSAGE sama BANAAG AGA NAAN ANA S 7 4 System Management Settings ccccccssseeecesesseeeeenseeeeeessseeesensneesses 8 1 Mise NG IWOIK SCNT Sa AA E 8 2 ACCESSI DIC UP TiS TT 8 2 SO INIVIP A CCN Se TTT 8 3 Chapter 9 Host BA APA 8 4 B AE 8 5 AMINE NU CAT
37. if 8 Device Control RealCOM NI NE 1G serial Port Status Go to Serial Port Status under Serial Status to view the current status of each serial port Serial Port Status gt Buffering Total Solution for Industrial Device Networking E Main Menu x Serial Port Status CJ Overview a Basic Settings IZ Auto refresh YG Network Settings Port TxCnt RxCnt TxTotalCnt RxTotalCnt DSR DTR RTS CTS DCD Buffering H Serial Port Settings 1 0 0 0 0 9 2 3 gt 0 3 System Management 2 0 o D 9 3 4 o na System Monitorin 4 S Q d ER lt lt 5 LA AAN 4 o 0 0 o gt 2 3 o ES Serial Status 5 o o O 0 gt gt 0 CJ Serial to Network Cc 6 o 0 0 9 Q gt 0 CJ Serial Port Status 7 E L 0 D 3 3 I 0 Cj Serial Port Error CoL 9 g E H Wap i ka d o E Serial Port Settings Monitor port buffering usage bytes of each serial port 8 15 CN2600 Series User s Manual System Management Settings Serial Port Error Count Go to Serial Port Error Count under Serial Status to view the error count for each serial port 2 Total Solution for Industrial Device Networking 4 Main Menu Serial Port Error Count Overview E Basic Settings Fl Auto refresh HQ Network Settings ma ErrCnt i 0 s CJ Serial Port Settings Frame Parity Overrun Break H System Management 1 o 0 0 0 Bede este ae 2 0 0 0 0 DS ystem Monitoring 4 6 6 z S Serial Status 4 n o n n K Serial to Network Cc 5 0 0 0
38. larger than that of Force transmit time To prevent the unintended loss of data due to the session being disconnected it is highly recommended that this value is set large enough such that the intended data transfer 1s completed Auto Link Protocol If this field is set to None the CN2600 will not connect to the host automatically If Auto Link Protocol is set to Telnet or Rlogin the CN2600 will connect to the host automatically using the specified protocol Primary and Secondary host address If specified the fields designate permanent hosts to which the terminal will always be connected Telnet TCP port default 23 By default the Telnet TCP port number is set to 23 which is the default TCP port number for Telnet Terminal type default ansi Some older terminal applications may require that the terminal type be transmitted before the connection can be established You may need to refer to the server s documentation to determine the appropriate terminal type For most applications this setting will be unnecessary and will have no effect Max Sessions default 4 This setting allows you to configure the maximum number of sessions allowed for the serial port Change Session default 4T 0x14 This field defines the quick key to change a session Quit default E 0x05 This field defines the quick key to quit a session Break This field defines the quick key to send a break signal Interrupt This field defines the quick
39. multiple hosts are connected and one or more of the hosts stops responding as the port is transmitting data If you select No the port will wait until the data has been transmitted successfully to all hosts before transmitting the next group of data If you select Yes the port will ignore the host that stopped responding and continue data transmission to the other hosts Primary IP address The primary host s IP address If left blank then every host on the network cannot access the serial port Backup 1 IP address Backup host s IP address Backup 2 IP address Backup host s IP address Backup 3 IP address Backup host s IP address TCP Port TCP data port number Via the data port users can retrieve data through the async line 6 18 CN2600 Series User s Manual Configuring Serial Port Operation Modes A TCP port command port number Via the command port users can issue commands across the network to set the line s configuration parameters such as baudrate data bits flow control condition etc Connection goes down default always high You can configure what happens to the RTS and DTR signals when the Ethernet connection goes down For some applications serial devices need to know the Ethernet link status through RTS or DTR signals sent through the serial port Use goes low if you want the RTS and DTR signal to change their state to low when the Ethernet connection goes down Use always high if you do not want the Ethernet connec
40. need to restart the CN2600 You may view and modify your changes by selecting IP address at the Network setting menu again Press the menu button to exit out of the Network setting menu and return to the Main Menu Use the UP and DOWN buttons to select Save Restart and press SEL Use the UP and DOWN buttons to select Yes and press SEL to restart You may use the ARP Address Resolution Protocol command to set up an IP address for your CN2600 The ARP command tells your computer to associate the CN2600 s MAC address with an IP address Afterwards use Telnet to access the CN2600 and its IP address will be reconfigured 3 3 CN2600 Series User s Manual ATTENTION In order to use the ARP setup method both your computer and the CN2600 must be connected to the same LAN Alternatively you may use a cross over Ethernet cable to connect the CN2600 directly to your computer s Ethernet card Before executing the ARP command your CN2600 must be configured with the factory default IP address 192 168 127 254 and your computer and the CN2600 must be on the same subnet Initial IP Address Configuration To use ARP to configure the IP address complete the following 9 Obtain a valid IP address for your CN2600 from your network administrator 10 Obtain your CN2600 s MAC address from the label on the bottom panel 11 Execute the arp s command from your computer s MS DOS prompt as follows arp s lt P address gt lt MAC address g
41. port uses to listen to connections and that other devices must use to contact the serial port To avoid conflicts with well known TCP ports the default is set to 4001 Packet length default 0 The Packet length setting refers to the maximum amount of data that is allowed to accumulate in the serial port buffer before sending At the default of 0 for packet length no maximum amount is specified and data in the buffer will be sent as specified by the delimiter settings or when the buffer is full When a packet length between 1 and 1024 bytes is specified data in the buffer will be sent as soon it reaches the specified length Delimiter 1 and Delimiter 2 default None When Delimiter 1 is enabled the serial port will clear the buffer and send the data to the Ethernet port when a specific character entered in hex format is received A second delimiter character may be enabled and specified in the Delimiter 2 field so that both characters act as the delimiter to indicate when data should be sent 6 5 CN2600 Series User s Manual Configuring Serial Port Operation Modes A ATTENTION In order to enable a delimiter packet length must be set to 0 Delimiter 2 should only be enabled in conjunction with Delimiter 1 and never on its own otherwise there may be data errors Even when a delimiter is enabled the CN2600 will still pack and send the data when the amount of data exceeds 1 KB Delimiter process default Do Nothing The Delimite
42. send the data to the Ethernet port when a specific character entered in hex format is received A second delimiter character may be enabled and specified in the Delimiter 2 field so that both characters act as the delimiter to control when data should be sent ATTENTION In order to enable a delimiter packet length must be set to 0 Delimiter 2 should only be enabled in conjunction with Delimiter 1 and never on its own otherwise there may be data errors Even when a delimiter is enabled the CN2600 will still pack and send the data when the amount of data exceeds 1 KB Delimiter process default Do Nothing The Delimiter process field determines how the data is handled when a delimiter is received Delimiter 1 must be enabled for this field to have effect If Delimiters 1 and 2 are both enabled both characters must be received for the delimiter process to take place e Do Nothing Data in the buffer will be transmitted when the delimiter is received e Delimiter 1 Data in the buffer will be transmitted after 1 additional byte is received following the delimiter e Delimiter 2 Data in the buffer will be transmitted after 2 additional bytes are received following the delimiter e Strip Delimiter Data in the buffer is first stripped of the delimiter before being transmitted Force transmit default 0 ms This parameter defines how large a gap in serial communication the CN2600 will allow before packing the serial data in its inte
43. servers will be unable to access it using a fixed IP address With DDNS Dynamic Domain Name Server a remote server can access the CN2600 using its domain name instead of its IP address Overview The following is a summary of the process 1 The CN2600 sends a request for an IP address to the DHCP server At the same time it notifies the DHCP server of its desired server name CN2600 in the illustration according to the option 12 standard 2 The DHCP server replies with the IP address that is assigned to the CN2600 along with the domain name moxa com in the illustration and the IP addresses for the DNS server and gateway 3 Tf the CN2600 has authorization to update the DNS server it will register its FQDN Fully Qualified Domain Name with the DNS server The CN2600 s FQDN will be in the format server name domain name CN2600 moxa com in the illustration 4 If the CN2600 is not authorized to update the DNS server the DHCP server can be used to update the DNS server The DHCP server will register the DNS server with the PTR RR the record of request for a domain name with IP address DHCP Server DHCP Request A NPort 6000 Series Host name NP6000 S E DHCP Acknowledge My fully qualified domain Domain name moxa com name FQDN is NP6000 moxa com P A a Us R Lei ll ang A P DNS Server CN2600 Series User s Manual E8 DHCP
44. that stopped responding and continue data transmission to the other hosts Allow driver control default No This option determines how the port will proceed if driver control commands are received from multiple hosts that are connected to the port If No is selected driver control commands will be ignored If Yes is selected control commands will be accepted with the most recent command received taking precedence TCP port default 4001 This is the TCP port number assignment for the serial port on the CN2600 It is the port number that the serial port uses to listen to connections and that other devices must use to contact the serial port To avoid conflicts with well known TCP ports the default is set to 4001 Command port default 966 The Command port is the TCP port for listening to SSDK commands from the host In order to prevent a TCP port conflict with other applications the user can set the Command port to another port if needed Packet length default 0 The Packet length setting refers to the maximum amount of data that is allowed to accumulate in the serial port buffer before sending At the default of 0 for packet length no maximum amount is specified and data in the buffer will be sent as specified by the delimiter settings or when the buffer is full When a packet length between 1 and 1024 bytes is specified data in the buffer will be sent as soon it reaches the specified length Delimiter 1 and Delimiter 2 default N
45. the serial port is set to 1200 bps 8 data bits 1 stop bit and no parity In this case the total number of bits needed to send a character is 10 bits and the time required to transfer one character is 10 bits 1200 bits s x 1000 ms s 8 3 ms Therefore you should set the force transmit time to be larger than 8 3 ms so in this case it must be greater than or equal to 10 ms If it is necessary to send a series of characters in the same packet the serial device will need to send that series of characters within the specified force transmit time and the total length of data must be less than or equal to the CN2600 s internal buffer size 1 KB per port 6 17 CN2600 Series User s Manual Configuring Serial Port Operation Modes DRDAS TCP Server SI Main Menu s a Operation Modes E Overview P J Basic Settings Port 1 HS Network Settings ma at A icati DRDAS v E Serial Port Settings re eet 0693 port i Mode DRDAS TCP Server CJ Communication P Inactivity time 0 0 65535 ms CI Data Buffering Lo Ignore jammed IP O Enable Disable Te CJ Modem Settings Primary IP address H Port 2 l Backup 1 IP address HE Port 3 HE Port 4 Backup 2 IP address PY Port 5 Backup 3 IP address S HG Port 6 TCP port 4001 Bo Port 7 Cmd port 966 C Port 8 Connection goes down RTS Oalways low always high LI Welcome Message DTR Qalwayslow always high HJ system Management a Data Packing
46. total number of bits needed to send 6 19 CN2600 Series User s Manual Configuring Serial Port Operation Modes a character is 10 bits and the time required to transfer one character is 10 bits 1200 bits s x 1000 ms s 8 3 ms Therefore you should set the force transmit time to be larger than 8 3 ms so in this case it must be greater than or equal to 10 ms If it is necessary to send a series of characters in the same packet the serial device will need to send that series of characters within the specified force transmit time and the total length of data must be less than or equal to the CN2600 s internal buffer size 1 KB per port Terminal Applications Terminal ASCII TERM ASC MOIN ODI Main Menu 1 Overview CJ Basic Settings CJ Network Settings IT Serial Port Settings 55 Port1 a E Operation Modes CJ Communication P at oa Data Buffering Lo CJ Modem Settings BG Port 2 BC Pot3 BC Port 4 B Ports BG Port 6 G Port G Ports J Welcome Message HY System Management CJ System Monitoring 9 Save Configuration S Restart Operation Modes Port 1 Application Mode TCP alive check time Inactivity time Auto link protocol Primary host address Secondary host address Telnet TCP port Terminal Terminal type Max sessions Change session Quit Break Interrupt Authentication tvoe Automatic Login Auto login prompt Password prompt Login user nam
47. will install NFort Search Utility Werd 1 on your computer It i recommended that you close all other applications before continuing Click Next to continue or Cancel to exit Setup Click Next to install program files to the default directory or click Browse to select an alternate location l Setup NPort Search Utility Select Destination Location Where should MPort Search Utility be installed iJ Setup will install NPort Search Utiity into the following folder To continue click Next Ifyou would like to select a different folder click Browse NG Program Kiez vN Garta earch Browse Atleast 1 0 MB of free disk space is required Cancel 9 2 Software Installation Configuration CN2600 Series User s Manual Software Installation Configuration 4 Click Next to install the program s shortcuts in the appropriate Start Menu folder Ha Setup NPort Search Utility Select Start Menu Folder Where should Setup place the program s shortcuts je Setup will create the program s shortcuts in the following Start Menu folder To continue click Next IF you would like to select a different folder click Browse NPort Search Utility Browse Z Back Cancel 5 Click Next to proceed with the installation The installer then displays a summary of the installation options a Setup NPort Search Utility Ready to Install Setup if now ready to begin installing NPort Searc
48. 00 Series User s Manual Additional Serial Port Setings should disable the port s FIFO setting if the attached serial device does not have a FIFO buffer of its own This is because a serial device that does not have its own buffer may not be able to keep up with data sent from the CN2600 s FIFO buffer Interface default RS 232 You may configure the serial interface to RS 232 RS 422 RS 485 2 wire or RS 485 4 wire Port Data Buffering Log E Main Menu 2 Data Buffering Lo RE Overview genes Basic Settings HE Network Settings a Serial Port Settings B Port 1 Operation Modes CJ Communication P ca Bata Butferingita SJ Modem Settings BG Port2 SO Port 3 XO Port 4 Po Port 5 pie Port 6 BA Port 7 BC Ports E Welcome Message ao System Management ag System Monitoring a Save Configuration Restart Port 1 Port buffering 128K Serial data logging 128K Apply the above settings to IZ gt O Enable Disable O Enable Disable P1 C P2 Cp3 CIP4 Ops pe C P7 Clips CAI ports The CN2600 supports port buffering to prevent the loss of serial data when the Ethernet connection is down Port buffering can be used in TCP Server mode TCP Client mode and Pair Connection mode For other modes the port buffering settings will have no effect Port buffering enable default No You may enable port buffering by setting this field to Yes Serial data logging enable d
49. 32 connector on the Remote Terminal Unit RTU shown above must be set up with an RS 232 to RS 422 485 converter such as the Moxa TCC 1001 to convert RS 232 signals to RS 485 signals The connectors on the two CN2600 terminal servers will also need to use converters such as the Moxa TCC 1001 In this way users can take advantage of RS 485 s multi drop feature to share data with the secondary CN2600 4 7 CN2600 Series User s Manual Serial Port Operation Modes Terminal Applications Windows NT A TCP IP 1 a CN 2600 Telnet ee CI eo ele Terminal Terminal Terminal Terminal applications involve connecting terminals to UNIX or Windows servers over a network A terminal connects to the appropriately configured serial port the CN2600 and the CN2600 transmits information to and from a UNIX or Windows server over the network through its Ethernet port You may need to check with your network administrator to determine the appropriate terminal mode All terminal modes support fast keys as used in many terminal applications Please refer to Chapter 4 Introducing Serial Port Operation Modes for detailed information and configuration instructions Terminal ASCII Mode Terminal ASCII mode can handle up to 8 sessions per port with the ability to switch between sessions on the same terminal This mode is used for text based terminals with no file transfer capability or encryption Terminal BIN Mode
50. 485 CN 2600 ST Device 8 pins Cable Wiring E 25 pins Data 5 3 Data Data 6 8 Data GND 3 7 GND Pin Assignments for DB9 and DB25 Connectors Pin Assignments for DB9 Male and Female Connectors DB9 Male Connector DSR in RTS out CTS in CO NO DB9 Female Connector Pin Assignments for DB25 Male and Female Connectors DB25 Male Connector O 1 DCD in DCD in 1 2 RxD in TxD out 2 i sala kany 3 TxD out RxD in 3 8 RTS out 4 DTR out DSR in 4 9 5 GND GND 5 O DB25 Female Connector 1 RxD in 2 Ja TxD out 3 CTS in 4 RTS out 5 DTR out 6 GND 7 DED in 8 20 DSR in 13 29 A 8 B SNMP Agent with MIB II Simple Network Management Protocol agent software is built into the CN2600 The software supports cold warm start trap line up down trap and RFC 1213 MIB II The following table lists the standard MIB II groups as well as the variable implementations for the CN2600 Supported SNMP variables fifAdminStatus 5858 lipInDiscards 55 rempImEchos L lifOperStatus 5858 lipInDelivers 75353983 empInEchoReps lifLastChangg 58 B7 ipOutRequests 7 7 8 IcmpInTimestamps i ipOutDiscards IcmpTimestampReps L liflnUcastPkts ___ ipOutNoRoutes_ _____ IcmplnAddrMasks_ L ifnNUcastPkts ___ ipReasmTimeout _ IcmpOutMsgs L liflnDiscards ______ ipReasmReqds________ IempOutErrors L liflnErrors 55858 ipReasmOKs IcmpOutDestUnreachs lifInUnknownProtos lip
51. 68 127 254 4 EJs Total Saiution for industrial Device Networking Ping Test CJ Overview 9 CI Basic Settings SE Network Settings ws eo Serial Port Settings DegunaHnn A aa System Management BE Misc Network Settings S Auto Warning Settings BS Maintenance CJ Console Settings Gi Ping CO Firmware Upgrade Ping Destination You can ping an IP address from the CN2600 web console in order to test the Ethernet connection Enter the IP address or domain name in the Destination field to make sure that the connection is OK Firmware Upgrade 3 NPort Web Console Microsoft Internet Explorer jol x File Edit View Favorites Tools Help D pad 3 D E G9 p Search 2 7 Favorites o Li Ev Ss Address http 192 168 127 254 L Total Solution for inawstaal Device Networking pa Asam ey Firmware Upgrade CJ Overview CJ Basic Settings u Warning eo Network Settings Note Upgrade firmware will discard your un sayed configuration changes and restart BE Serial Part Settings the system 2723 system Management Select firmware file O SE Misc Network Settings a Auto Warning Settings PANATA EXSY Maintenance Submit E Console Settings CI Ping CJ Firmware Upgrade Cl Configuration Import O Canfinuratinn Fenn The CN2600 s firmware can be upgraded though the web console serial console or through NPort Search Utility If you have made any changes to your configur
52. Action view Tree E B root Sqg4qk 6nd Foal Scope 192 General DNS Advanced You can set up the DHCP server to automatically update name and address information on DHS servers that support dynamic updates M Automatically update DHCP client information in DNS Update DNS only if DHCP client requests C Always update DNS Discard forward name to address lookups when lease expires Dynamic Domain name Serve Scope 192 168 70 0 DN moxa com tw Properties ts that do not support dynamic update nfigured in TCP IP properties for EIver OF Cancel Apply The above screenshot shows how DHCP can be set up to update the DNS Currently the CN2600 supports DNS service as provided by DynDNS For detailed information on this option please visit https www dyndns com Configuration Pa ae aq BO Le is aq EL Port 9 Port 10 Port 11 Port 12 Port 13 Port 14 p Port 15 BC Port 16 CJ Welcome Message Bia System Management a Misc Network Settings E N Accessible IP List E SNMP Agent C2 DDNS 18 Host Table Ro Route Table N User Table Authentication Server o I System Log Settings Sl Auto Warning Settings a Maintenance Certificate ag System Monitoring N Save Configuration HA Restart DDNS Configuration DDNS Server address Host name Username Password Total Solution for Industrial Device Networking Enable Disable D
53. Be System Monitoring Save Configuration Packet length O 0 1024 BG Restart Delimiter 1 00 Hex Enable Delimiter 2 00 Hex C Enable Delimiter process Do Nothing Processed only when Packing length is 0 Force transmit o 0 65535 ms EPE E E P1 IP2 OP3 C P4 TIPS CIP6 OFP CPs CIAl ports a i TCP alive check time default 7 min This field specifies how long the CN2600 will wait for a response to keep alive packets before closing the TCP connection The CN2600 checks connection status by sending periodic keep alive packets If the remote host does not respond to the packet within the time specified in this field the CN2600 will force the existing TCP connection to close For socket and device control modes the CN2600 will listen for another TCP connection from another host after closing the connection If TCP alive check time is set to 0 the TCP connection will remain open even if there is no response to the keep alive packets Inactivity time default 0 ms This field specifies how long the CN2600 will wait for incoming and outgoing data through the serial port before closing the TCP connection The TCP connection is closed if there is no incoming or outgoing data through the serial port for the specified Inactivity time If this field is set to 0 the TCP connection is kept active until a connection close request is received Ignore jammed IP default No This option determines how the port will proceed if
54. CN2600 Series Dual LAN Terminal Server User s Manual Third Edition November 2010 www moxa com product MOXA 2010 Moxa Inc all rights reserved Reproduction without permission is prohibited CN2600 Series Dual LAN Terminal Server User s Manual The software described in this manual is furnished under a license agreement and may be used only in accordance with the terms of that agreement Copyright Notice Copyright 2010 Moxa Inc All rights reserved Reproduction without permission is prohibited Trademarks MOXA is a registered trademark of Moxa Inc All other trademarks or registered marks in this manual belong to their respective manufacturers Disclaimer Information in this document is subject to change without notice and does not represent a commitment on the part of Moxa Moxa provides this document as is without warranty of any kind either expressed or implied including but not limited to its particular purpose Moxa reserves the right to make improvements and or changes to this manual or to the products and or the programs described in this manual at any time Information provided in this manual is intended to be accurate and reliable However Moxa assumes no responsibility for its use or for any infringements on the rights of third parties that may result from its use This product might include unintentional technical or typographical errors Changes are periodically made to the information he
55. Device Networking Errsum SNoRoute ErrProta ErrPorts ErrPorts Opens 10 Sent Sent SDiscard Sent SDiscard ErrAddr Sent SEchoReg SEchoRply Sent Sent Resent Data logs for each serial port can be viewed in ASCII or HEX format After selecting the serial port and format you may click Select all to select the entire log if you wish to copy and paste the contents into a text file wp Total Solution for Industrial Device Networking A ag Port 6 RD Port AE Port 8 RD Porto ef Port 10 ef Port 11 ef Port 12 SIS Port 13 ef Port 14 ef Port 15 ef Port 16 CJ Welcome Messag bie system Managemer Bey System Monitoring ef Serial Status og System Status O Network Conne Gad Network Statis fi Serial Data Log ti System Log LW nating Serial Data Log Data Log ASCII Select port Port Select all Clear log Refresh 8 17 ASCIT HEX E CN2600 Series User s Manual System Management Settings System Log This option displays the system log You may click Select all to select the entire log if you wish to copy and paste the contents into a text file Total Solution for Industrial Device Networking HE porte YG Port7 PS Port 8 System Log BC Porto BC Port 10 NS Port 11 BC Port 12 BC Port 13 HE Port 14 BG Port 15 BC Port 16 Welcome Messag System Log Gg System Managemer ic System Monitoring YG Serial Status
56. E Port 2 BE Port3 BG Port4 E lS Port 5 8G Porto B Port7 E eE Port8 E CJ Welcome Message ngg System Management BG System Monitoring fa Save Configuration CJ Restart L Network Settings Basic LAN1 IP configuration LAN1 IP address LAN1 Netmask LANI Gateway LANI speed LANI PPPoE user account LAN1 PPPoE password LAN2 IP configuration LAN2 IP address LAN2 Netmask LAN2 Gateway LAN2 speed LAN2 PPPoE user account LAN2 PPPoE password DNS server 1 DNS server 2 WINS function WINS server A DHCP v Auto m Static 192 168 126 254 255 255 255 0 Auto E Enable Disable R a You can access Basic Network Settings by expanding the Network Settings item in the navigation panel Basic Network Settings is where you assign the CN2600 s IP address netmask Gateway and other IP parameters NOTE You must assign a valid IP address to your CN2600 before it will work in your network environment Your network system administrator should provide you with a unique IP address and related settings for your network First time users can refer to Chapter 3 Initial IP Address Configuration for more information 5 7 CN2600 Series User s Manual Configuration with the Web Console A IP configuration default Static You can choose from four possible IP configuration modes BOOTP server as
57. EM Console Eton Pane T 3 2 PA AA O AA AA AA uauceseinaaaes 3 3 Temet CONO PA OO 3 4 Seral CONSO Eaa a N dana O 1 2 3 9 Serial Port Operation Modes ss sssssssssssssessss essen 4 1 OVEN aa AA aaa AG 4 2 Device Control Applications aa AA AA NAGA 4 2 Real COM MOTEL maa eee kad agahan balad hd alba daa cada aah Nah ue bata 4 3 REC22L M00 Gp aka NANA a 4 3 KTTO N TRR pe Nana r RA haaa 4 3 TGP Server Mode aa DA a PAA Bs 4 4 TCRG MOJ AA AAP AGAPAN 4 4 UDP Moda ENE 4 5 Redundant CO Naka aaah NAA Aa kaa 4 5 Dual host Redundant Data Acquisition System DRDAS 11110777 7 7 7 7 7 a 4 6 Temal Ap WCAG ONS aa a ete cantare cuca see a AN eee add 4 8 Terminal ASCH MOC T 4 8 Tema BIN Ta TTT 4 8 Reverse Terminal Applic aon LT 4 9 Reverse Lo MET renn Reem me AA te nT ne Pee ND APA BABAY 4 9 Dial OU MOUE AGA AN AA AA 4 10 Ree L 0 16 TTT 4 10 Chapter 5 Chapter 6 Chapter 7 Chapter 8 Configuration with the Web Consolle cccecceeeeeeeeeeeeeeeeeeeeeeseeneeees 5 1 Using Your WED BLOW SED T 5 2 Browser COOKIE ETT 5 2 ASK SILC AA 5 3 Opening Me Web Ons Ole pama NAAN 5 4 Web Console Navi ation muah oducesntsusqueanaveagectnsauusoanasaheotonaaueneatoupesdaaqeuiacauesnectosaeutios 5 5 BASO S CLINGS aaa ann AANGAL maana nanana 5 6 COV Cl SE TTT 5 6 ST AMIS SeN TTT 5 6 ING CW OTK IS AA 5 7 Basie NENGKA INENG AAO NG NAAN E AA 5 7 Advanced NETWORK SeN Soraia ETE aala hatak saan 5 9 Conan nhe Route Tab amak leh dobeohor
58. Ethernet port when a specific character entered in hex format is received A second delimiter character may be enabled and specified in the Delimiter 2 field so that both characters act as the delimiter to indicate when data should be sent ATTENTION In order to enable a delimiter packet length must be set to 0 Delimiter 2 should only be enabled in conjunction with Delimiter 1 and never on its own otherwise there may be data errors Even when a delimiter is enabled the CN2600 will still pack and send the data when the amount of data exceeds 1 KB Delimiter process default Do Nothing The Delimiter process field determines how the data is handled when a delimiter is received Delimiter 1 must be enabled for this field to have effect If Delimiters 1 and 2 are both enabled both characters must be received for the delimiter process to take place e Do Nothing Data in the buffer will be transmitted when the delimiter is received e Delimiter 1 Data in the buffer will be transmitted after 1 additional byte is received following the delimiter e Delimiter 2 Data in the buffer will be transmitted after 2 additional bytes are received following the delimiter e Strip Delimiter Data in the buffer is first stripped of the delimiter before being transmitted Force transmit default 0 ms This parameter defines how large a gap in serial communication the CN2600 will allow before packing the serial data in its internal buffer for netwo
59. Fortz K 3 COM 20 192 168 354 219 952 968 Port3 L 4 COM 1 19216534 219 953 969 Port4 l S CDM22 192 168 34 219 954 970 Port ten b COM23 142 168 534 219 355 971 Porte L 7 CDM 24 192 168 34 219 966 972 Port7 L S CUM 25 152 168 354 219 957973 Porte L 9 COME 192 166 354 219 955 974 Port ld 10 COMey 192 168 534 219 969 975 Port U L 11 COM25 192 168 34 219 960 976 Port11 bi v 12 COM 192 162 354 719 961 977 Port12 AA 13 COM 20 192 168 34 219 962 978 Port1 3 LHAT 14 COMIT a 19916004 119 962 979 IPoA L s xij 3 16 L i Do you want to activate the COM Port now NG Total OM Port ve 5 In Windows XP a message is displayed during activation of each port indicating that the software has not passed Windows Logo certification Click Continue Anyway to proceed Hardware Installation HAN NPort Communication Port 1 has not passed Windows Logo testing to verify its compatibili with Windows XP Tell me w y this testing is important Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and passed Windows Logo testing Continue Anyway STOP Installation 9 12 CN2600 Series User s Manual 6 Ports that have been activated will appear in black e NPort Windows Driver Manager
60. From e mail address This is the e mail address from which automatic e mail warnings will be sent To e mail address 1 to 4 This is the e mail address or addresses to which the automatic e mail warnings will be sent 8 9 CN2600 Series User s Manual System Management Settings 3 NPort Web Console Microsoft Internet Explorer File Edit View Favorites Tools Help GG sa G g D E P ppa Search 17 Favorites o e TE Fl Ss Address E http 192 168 127 254 JE EJ s 18 x Total Saiution for industrial Device Netwerking en Den SNMP Trap CI Overview Basic Settings SNMP Trap HL Network Settings ae Serial Port Settings SNMP trap receiver IP B89 system Management Trap version yi v2c BG Misc Network Settings Trap community public BS Auto Warning Settings HE Event Settings IE e Submit CJ Serial Event Settings E E mail Alert 5 CJ SNMP Trap Bi Maintenance SNMP trap server IP Use this field to indicate the IP address to use for receiving SNMP traps Trap version default v2 Use this field to select the SNMP trap version Trap community default public Use this field to designate the SNMP trap community Maintenance Console Setting lt 4 NPort Web Console Microsoft Internet Explorer File Edit view Favorites Tools EN Address http mog 168 127 254 JE g Go Total Salutjon for Industrial Device Networking Cal Main Menu Console Settings CJ Overview
61. H SO Port 11 TCP 0 O 192168197 98490 o LISTEN EG Port 12 TCR o 0 192 168 127 254 443 LISTEN NG Port 13 TCP o O 192 168 127 254 29 LISTEN BEY Port 14 TCP g 0 192 168 127 254 22 LISTEN ee TCP g 0 192 168 127 254 950 LISTEN i TCP o O 192 168 127 254 951 LISTEN Ei Port 16 TCR o O 192 1698 127 254 952 LISTEN E 0 Welcome Message TCF U U 192 168 127 254 952 T LISTEN ea cy ctom Monkohha TCP o 0 192 168 127 254 955 E LISTEN SE TCP o 0 192168127254956 LISTEN OL Sala Stall TCP 0 0 1991681979841957 LISTEN EXSY System Status TCP o 0 192168127254959 LISTEN E Network Connecti TCP 0 0 1921681272854959 LISTEN a a AA oe TCR n Mo 1971AA127 2540AN ISTEN 8 16 CN2600 Series User s Manual Network Statistics System Management Settings Go to Network Statistics under System Status to view network statistics ea Port 6 A BOI port SIE Port 8 803 Porto HE Port 10 ae Port 11 HG Port 12 HE port 13 Efe Port 14 BG Port 15 ag Port 16 ii Welcome Message HL System Management ng System Monitoring Bo Serial Status oag System Status i Network Connecti i Network Statistics E Serial Data Log Serial Data Log Network Statistics ETHERNET PPP IP ICMP UDP TCP Received Received RDiscard Received RDiscard ErrHeader Received REchoReg REchoRply Received ErrHeader Received ErrHeader CurrEstab wp Total Solution for Industrial
62. Line Phone Line Ethernet a T T T Ethernet 20266 Ll 20122 lb Bf 4 M PC PC PC PC For multi location enterprises CN2600 servers can be placed in different branch offices and used as both multi point routers and as remote access servers When hosts e g the Web FTP and E mail News servers shown in the figure send requests to hosts on another network such as 202 6 6 xxx or 201 2 2 xxx the corresponding CN2600 delivers the request to the another CN2600 on the remote end 202 6 6 254 or 201 2 2 254 as the next hop router 5 13 CN2600 Series User s Manual Configuration with the Web Console For this example assume that Modem is connected to serial port 1 Modem 2 is connected to serial port 2 and PPP source and destination IP addresses of modems 1 2 3 and 4 are as follows Modem 1 203 67 6 250 202 6 6 250 Modem 3 202 6 6 250 203 67 6 250 Modem 2 203 67 6 249 201 2 2 249 Modem4 201 2 2 249 203 67 6 249 In this case you will need to add two entries to the routing table as shown in the following figure 34 Main Menu as Route Table CJ Demp vin Ca RANG Sanne Mo Gateway Destination Netmask Metric Iface Bi Nobwork Solen s S L 2023 67 6 254 210 06 06 0 255 255 255 355 1 porki Fi seral Port Settings e m 1 ports ka 2 774 Brtn Managemhank SA Misc Network Settings 3 1 kami je Ej Amena IP Lest 4 I lanl CI SNMP Agent 5 1 lani ae Sy DONS 1 lami x CI Host Table pa Pi ri L Route Tabli lani m E U
63. Maintenance fa Console Settings Submit m Ping 1 Firmware Upgrade fa Configuration Import fa Configuration Export fa Load Factory Default t Change Password HE Certificate Gina System Monitoring ANA ea This function will reset all of CN2600 s settings to the factory default values All previous settings including the console password will be lost If you wish to keep the CN2600 IP address netmask and other IP settings make sure Keep IP settings is checked off before loading the factory defaults Change Password Total Solution for Industrial Device Networking SI Main Menu Change Password LI Overview i Basic Settings A HQ Network Settings ner asswor H Serial Port Settings r aa EN System Management NRW BARSWANY ao Misc Network Settings Confirm password YG Auto Warning Settings B Maintenance ba an Submit I Console Settings T La Bing a Firmware Upgrade Ga Configuration Import fa Configuration Export a Load Factory Default E E Change Password Certificate l System Monitoring A Save Canfiniiratinn For all changes to the CN2600 s password protection settings you will first need to enter the old password Leave this blank if you are setting up password protection for the first time To set up a new password or change the existing password enter your desired password under both New password and Confirm password To remove password protection leave the New passwo
64. Manual TCP Socket 53 79 119 123 213 eane Pat Network Time Protocol IPX 160 to 223 Reserved for future use Kaea Remote Telnet Service Sun Remote Procedure Call Sunrpc Network News Transfer Protocol NNTP Network Time Protocol NTP SNMP Simple Network Mail Protocol SNMP Traps IPX used for IP Tunneling D 2 Well Known Port Numbers E RADIUS Server Managing diverse serial lines and modem pools for large numbers of users creates the need for significant administrative support Since modem pools are links to the outside world careful attention must be paid to security authorization and accounting This can best be achieved by managing a single database of users allowing authentication verifying user names and passwords as well as configuration of information that details the type of service to deliver to the user e g SLIP PPP Telnet and rlogin The CN2600 supports the RADIUS protocol which requires only one database for remote user management This appendix covers the following topics E D U U CU U What is RADIUS gt Definition gt Client Server Architecture Setting up the CN2600 gt Setting up the RADIUS Server IP Address gt Serial Port Configuration Setting up UNIX Hosts Setting up Windows NT Hosts Setting up Windows 2000 Hosts Setting up Windows 2003 Hosts CN2600 Series User s Manual RADIUS Server What is RADIUS Definition Remote Authentication Dial
65. N26501 16 2AC RS 232 Console Port CN26501 8 2AC CN2600 Series User s Manual Introduction Socket 7 Port AC Power Input Automatic detection of 100 240V 47 63 Hz AC power supply Power On Off Switch I indicates power on O indicates power off AC models only 8 pin RJ45 RS 232 port for console terminal connection LAN 1 8 pin RJ45 auto detectable 10 100 Mbps UTP port LAN 2 8 pin RJ45 auto detectable 10 100 Mbps UTP port 8 or 16 8 pin RJ45 or DB9 ports for DCE modem type connections Bottom Label The server s serial number and MAC address are printed on a label fixed to the bottom of the server The CN2600 has 2 LAN ports each with its own MAC address The MAC address is the unique hardware Ethernet address used to identify a network hardware product Write each of the two MAC addresses in the space provided below for future reference LAN 1 MAC address LAN 2 MAC address 2 Hardware Installation This chapter includes instructions on where and how to install the CN2600 dual LAN terminal server Both basic and advanced software configuration instructions are given The following topics are covered in this chapter Desktop Rackmount Wiring Requirements Connecting the CN2600 8 16 s Power Connecting to the Network Connecting to a Serial Device Connecting to the Console Port Adjustable Pull High Low Resistors for the RS 485 Port U U U CU U CU U U CN2600 Series User s Manual Hardware Installation
66. None v ogin assword P1 p2 OPa O P4 Ops Cl P6 CIP7 OPs O All ports Terminal Binary mode can be used to transfer files with XMODEM or ZMODEM You are only allowed to open one terminal session at a time when in Terminal Binary mode TCP alive check time default 7 min This field specifies how long the CN2600 will wait for a response to keep alive packets before closing the TCP connection The CN2600 checks connection status by sending periodic keep alive packets If the remote host does not respond to the packet within the time specified in this field the CN2600 will force the existing TCP connection to close For socket and device control modes the CN2600 will listen for another TCP connection from another host after closing the connection If TCP alive check time is set to 0 the TCP connection will remain open even if there is no response to the keep alive packets Inactivity time default 0 min This field specifies how long the CN2600 will wait for incoming and outgoing data through the serial port before closing the TCP connection The TCP connection is closed if there is no incoming or outgoing data through the serial port for the specified Inactivity time If this field is set to 0 the TCP connection is kept active until a connection close request is received ATTENTION Inactivity time should at least be set larger than that of Force transmit time To prevent the unintended loss of data due to the sessio
67. ON S CLV CL AY 8 6 SV StCM OS RTT 8 6 POW APIS SENOS prosop ooi ase a n e ba tat oouteoneuohsosnndaulouaneaptedebgente saugubsnbandguieass 8 7 Pent aT 8 7 K THH ST SCUDI S iaie tna a a E mehasieniarveee 8 8 E ma e e E E T OA 8 9 SNMP TrID AA AA 8 10 Mantang T H damn aaa ON O TOOT 8 10 Console Sc a T E e N 8 10 P a a eh nea AA 8 11 Fw at Upo AA 8 11 Con eurai e MPO EDO eener a A E ET A 8 12 Load Factory Derilis zrnin A E E E TET E 8 13 CHANGE Passworde oa r S estan E A ake cames ektnwigts 8 13 E e PA 8 14 Biherme SoL Cercate Mpi renc E A 8 14 Cer tii Cate Key De GA 8 14 ANAN NA 8 15 Seral O NETWORK C ONNE CHONS seridir deta anas DADAAN AGUA ANA NA pA E EEE 8 15 CPLA a a TTT 8 15 Serial RORO COUN 3 a NGI ANNA kakasa 8 16 senal Porn HIE H a A 8 16 AGA KGG NI CTIONS oriai ie AA 8 16 Network AA AA AA nels 8 17 SC AL DATE O TTT 8 17 SVU ETT 8 18 AA 8 18 Dave CONMCULAN ON nara maa T E A biktaa n3 8 19 RES maa anh NANA AA GANAN kakanan 8 19 REIES AA ent ane cesashehaeran 8 19 Restt TTT 8 20 Software lnstallationConhguratiion ssssssssessss sese ss sec sese ss sees ee neee 9 1 IOB ORL SAC AA 9 2 Imstalling NPort Search UND n E TTE ER 9 2 Configuring NPort Search Utility sese 9 4 Windows Diver Manaset makaka NA AD 9 7 Installing NPort Windows Driver Managert sss sese 9 7 Using NPort Windows Driver Manager sese sese 9 10 Windows Monitor Bs voesce eian KANAN AO AIN Aa AA akn 9 17 Installing the NPort Monitor Utility cccccssssssessseeeeec
68. P check default None This field allows you to configure the method used if any to verify a user s ID and authorization Verify the ID against the CN2600 User Table RADIUS Verify the ID against the external RADIUS server Authentication is not required Disconnect by default None If this field is set as DCD off the connection will be disconnected when the DCD signal is off If this field is set as DSR off the connection will be disconnected when the DSR signal is off SLIP Mode MOXA DI Main Menu A HE Overview Operation Modes a Basic Settings a Network Settings Port 1 EM Serial Port Settings Application Dial infout ag ET Port 1 Mode SLIP M 4 Operation Modes Destination IP address E Communication P CJ Data Buffering Lo CJ Modem Settings Source IP address IP netmask EY Porto TCP IP compression O Enable Disable Y Port3 Inactivity time O 0 65535 ms ao Port4 Disconnect by None BG ports P1 Ope Cp3 Cp4 Ops CPs Op7 OPs Hy Ports Apply the above settings to Fall ports 2 Port 7 BG Port 8 CJ Welcome Message OC System Management a System Monitoring E CJ Save Configuration HE Restart lt gt SLIP provides standard SLIP service for both dial in and dial out Destination IP address This is the IP address of the remote dial in dial out server Source IP address The Source IP address is IP address assigned to this serial port IP netmask T
69. P on demand is used for dial in services since it provides SLIP services only when receiving a request from a remote PC Destination IP address This is the IP address of the remote dial in dial out server Source IP address The Source IP address is IP address assigned to this serial port IP netmask The IP netmask defines the netmask also known as the subnet mask for the SLIP connection TCP IP compression default No The setting of this field depends on whether the remote user s application requests compression Inactivity time default 0 ms This field specifies the idle time setting for auto disconnection A setting of O ms will cause the port to remain connected even if idle Disconnect by default None If this field is set as DCD off the connection will be disconnected when the DCD signal is off If this field is set as DSR off the connection will be disconnected when the DSR signal is off 6 27 CN2600 Series User s Manual Dynamic Mode Configuring Serial Port Operation Modes J Main Menu CJ Overview ge Basic Settings ag Network Settings EY Serial Port Settings 929 Porti Operation Modes CJ Communication P CJ Data Buffering Lo 5 CJ Modem Settings HE Port 2 Gie Port 3 BG port 4 BG Port5 a Port 6 BC Port BG Porta E Welcome Message Si System Management oi System Monitoring CI Save Configuration HE Restart lt A Operation Modes
70. Port 1 AJ Network Settings v v l E i ati ice Cont v ES Serial Port Settings chatedra ora on ro Se tore Made Realcom lt E E Operation Modes TCP alive check time I7 ko 99 min CJ Communication P Max connection PE E 4 Data Buffering Lo Ignore jammed IP Enable Disable CJ Modem Settings Allow driver control Enable Disable SA Port2 Connection goes down RTS O always low always high i ag Port 3 DTR O always low always high BG a EN 4 Part 4 Data Packing HD Ports Paga HE Port 6 Packet length 0 O 1024 SE Port 7 Delimiter 1 00 Hex Enable ao Port 8 Delimiter 2 loo Hex C Enable II Welcome Message Delimiter process Do Nothing v Processed only when Packing length is D CJ System Management Force transmit 0 0 65535 ms PER P System Monitoring l pti Ere Ors Erpe Ers Ore Der Ope CJ Save Configuration Apply the above settings to arai orts HH Restart gt v w SE Select Operation Modes in the navigation panel to select and configure the mode for each serial port For CN2600 models with 2 or more serial ports you may use the checkboxes at the bottom of the window to apply the settings to one or more ports Application Select an application for the serial port from among the choices Your application will determine the modes that are available Mode Once you have chosen an application select the mode The available configuration settings will vary depending on the mod
71. RADIUS server Authentication is not required Auto login prompt default ogin Password prompt default assword Login user name Enter the terminal login ID here Login password Enter the password for the terminal login here Reverse Terminal Total Solution for Industrial Device Networking SY Serial Port Settings E Danian adas S Port 1 F CJ Operation Modes MAI 4 Communication Parameters erre a ication everse Termina 9 Data Buffering Log N Reverse Toni Ga Modem Settings Mode Reverse Telnet CJ Cipher Settings TCP alive check time 7 0 99 min Hi Port 2 Inactivity time fo O 99 min at Port 3 TCP port 4001 on T mapa Terminal gg Ports Authentication type None x H Port 6 HE Port7 Map keys lt CR LF gt CR LF lt l HE Ports pi Fp2 T p3 pA pS T P6 Ti p7 T Pg na Apply the above 0 Port 9 settings to PU pa T pio fF pii FT p12 p13 F pi4 pis P16 SG Port 10 T All ports H port 11 HG Port 12 v Port 13 Submit TCP alive check time default 7 min This field specifies how long the CN2600 will wait for a response to keep alive packets before closing the TCP connection The CN2600 checks connection status by sending periodic keep alive packets If the remote host does not respond to the packet within the time specified in this field the CN2600 will force the existing TCP connection to close For socket and device cont
72. ReasmFailss55S57M7BempOutTimeExeds L fifOutOctets 858 ipFragOKs 3S IcmpOutParmProbs L lifOutUcastPkts 85BlipFragFails 7 IcmpOutSrcQuenchs lifOutNUcastPkts _ ipFragCreates___IcmpOutRedirects L lifOutDiscards __fipAdEntAddr_ IcmpOutEchos O lifOutErrors 5 59 57 ipAdEntfIndex 8 lcmpOutEchoReps lifOutQLen 3S ipAdEntNetMask 5 8 IempOutTimestamps L lifSpecific 78585 lipAdEntBcastAddr 858 87 IcmpOutTimestampReps UU lipAdEnReasmMaxsize _ lompOutAddrMasks S IpNetToMedialflndex 8 IcmpOutAddrMaskReps L pNetToMediaPhysAddress O L 0pNetToMediaNetAddress po B838 pNetToMediaType O fpRoutingDiscards CN2600 Series User s Manual SNMP Agent with MIB II Po ftepAttempFails snmpInNoSuchNames snmpInGenErrs AtNetAddress tcpOutSegs snmpInTotalReq Vars po tepRetransSegs snmplnTotalSetVars po tepComnState 535353535393 snmpInGetRequests __ po ftepConnLocalAddress _ snmpInGetNexts tcpConnLocalPort snmpInSetRequests L tepComnRemAddress __ snmpInGetResponses po tepComnRemPort SS snmpInTraps po smmpOutBadValues Eu L snmpOutGetRequests po snmpOutGetNexts Ooo o snmpOutSetRequests L snmpOutGetResponses po snmpOutTraps L snmpEnableAuthenTraps B 2 C Dynamic Domain Name Server This appendix explains how to use the CN2600 with DDNS When the CN2600 receive its IP address from a DHCP Dynamic Host Configuration Protocol server remote
73. TION If you forget your password the ONLY way to configure the CN2600 1s by using the reset button to reset all settings and load the factory defaults If you have disabled the reset button in your CN2600 configuration you may still use it to load the factory defaults within the first 60 seconds that the CN2600 is powered on Remember to back up your configuration by exporting it to a file Your configuration can be easily restored by importing the file to the CN2600 This will save time if you have forgotten the password and need to reload the factory defaults 4 The CN2600 s web console will appear SI Main Menu l i a Welcome to Terminal Server CN2600 Series CO Overview CJ Basic Settings Model name CN2650 8 2Ac 1 Network Settings Serial No 0 FS Serial Port Settings Firmware version 1 0 Build 07091017 BG Port1 LAN1 IP address N A _ LAN1 MAC address 00 90 E8 12 69 87 PG Port2 LAN1 speed No link i GAS Port 3 LAN2 IP address 192 168 126 254 i HY Port 4 LAN2 MAC address 00 90 E8 12 69 88 By Port 5 LAN2 speed 100M Link L Up time O days 00h 24m 08s MM Aree CAD Serial port 1 115200 None 8 1 BH Port7 Serial port 2 115200 None 8 1 HE Ports Serial port 3 115200 None 8 1 Oj Welcome Message Serial port 4 115200 None 8 1 9 Ga System Management Serial port 5 115200 None 8 1 ae er Serial port 6 115200 None 8 1 ak bA Serial port 7 115200 None 8 1 4 Save Configuration Serial port 8 115200 None 8 1 HY Resta
74. Telnet 192 168 0 102 N2650 8 2AC CN2650 8 2NCB 1 8 System vT AA UA Restart the server ESC back to menu Enter select Warning ttt Restart system will disconnect all ports and clear all status value Enter continue ESC cancel Serial Console The CN2600 supports configuration through the serial console which is the same as the Telnet console but accessed through the RS 232 console port rather than through the network Once you have entered the serial console the configuration options and instructions are the same as if you were using the Telnet console The following instructions and screenshots show how to enter the serial console using PComm Terminal Emulator which is available free of charge as part of the PComm Lite suite You may use a different terminal emulator utility although your actual screens and procedures may vary slightly from the following instructions L Use a serial cable to connect the CN2600 s serial console port to your computer s male RS 232 serial port From the Windows desktop select Start gt All Programs gt PComm Lite gt Terminal Emulator The PComm Terminal Emulator window should appear From the Port Manager menu select Open or simply click the Open icon as shown below Bi PComm Terminal Emulator 3 9 CN2600 Series User s Manual Initial IP Address Configuration 4 The Property window opens automatically Select the Communication Parameter tab and then select the appropriat
75. aa System Management ao Misc Network Settings ag Auto Warning Settings BO Maintenance BG Certificate Select all submit ne System Monitoring ag Serial Status HE System Status O Save Configuration 9 24 Restart A Restart System E Restart Ports Nilo Os Da Os D6 OF G8 Eog Oio DiGi Ois 14715 16 8 20 9 Software Installation Configuration The following topics are covered in this chapter LJ NPort Search Utility gt Installing NPort Search Utility gt Configuring NPort Search Utility LJ Windows Driver Manager gt Installing NPort Windows Driver Manager gt Using NPort Windows Driver Manager LJ Windows Monitor Utility gt Installing the NPort Monitor Utility gt Using the NPort Monitor Utility Q Linux Real TTY Drivers Basic Procedures Hardware Setup Installing Linux Real TTY Driver Files Mapping TTY Ports Removing Mapped TTY Ports VV Y Y Y Y Removing Linux Driver Files Q The UNIX Fixed TTY Driver gt Installing the UNIX Driver gt Configuring the UNIX Driver CN2600 Series User s Manual NPort Search Utility Installing NPort Search Utility L Click the INSTALL UTILITY button in the Installation CD auto run window to install NPort Search Utility Once the program starts running click Yes to proceed 2 Click Next when the Welcome screen opens to proceed with the installation 3 Setup NPort Search Utility Welcome to the NPort Search Utility Setup Wizard This
76. able The CN2600 supports PPP SLIP and Terminal modes for dial in dial out access Regardless of which operating system is used you will always be able to use standard PPP dial up to establish a connection The CN2600 can also act as a router to connect serial ports to a WAN connection Routing protocols including static RIP I and RIP II can be adjusted to route different WAN connections Please refer to Chapter 5 Configuration with Web Console for detailed information and configuration instructions Disabled Mode You can disable any port on the CN2600 by setting the operation mode to Disabled 4 10 5 Configuration with the Web Console The web console is the most user friendly method available to configure the CN2600 With a standard web browser you have easy and intuitive access to all settings and options In this chapter we introduce the web console and go through the basic configuration options The same configuration options are also available through the Telnet and serial console This chapter covers the following topics Q Using Your Web Browser gt Browser Cookie Settings gt Trusted Site Settings gt Opening the Web Console Q Web Console Navigation LI Basic Settings gt Server Settings gt Time Settings LI Network Settings gt Basic Network Settings gt Advanced Network Settings gt Configuring the Route Table CN2600 Series User s Manual Configuration with the Web Console Using Your Web Browser
77. ade via Flash ROM Package Checklist All CN2600 dual LAN terminal servers are shipped with the following items e CN2600 dual LAN terminal server e AC power cord e Document and Software CD ROM e Quick Installation Guide English and Simplified Chinese versions e RJ45 Loopback Tester e Product Warranty Statement e Rackmount Kit includes 2 brackets and 8 screws e Desktop Kit includes 4 pads 1 2 CN2600 Series User s Manual Introduction Front Panel LCM Display Panel Push Buttons LED Indicators LAN Indicators CN2610 8 V4 Reset Button Ready LED Power Indicator CN2650 16 CN2610 16 V4 A v CN2610 8 2AC CN2610 16 2AC CN2650 8 CN2650 16 CN2650 8 2AC A M Ready On 6 6 666666 CN2610 16 2AC Terminal Server N2650 16 2A a O BT CN26501 8 Terminal Server CN26501 8 CN26501 16 N CN26501 8 2AC AN CN26501 16 2AC Terminal Server CN26501 16 2AC CN2600 Series User s Manual Introduction Buttons and LEDs Press the Reset button for 5 seconds to load factory defaults The CN2600 Reset Button will beep twice when the configuration has been reset LEDs Red Powerconnection SSOS S a Rear Panel Power Input 10 100 BaseT Ethernet Ports RJ45 Serial Ports CN2610 16 2AC CN2650 16 2AC CN2610 8 2AC CN2650 8 2AC Power Input 10 100 BaseT Ethernet Ports DB9 Serial Ports C
78. al Solution for Industrial Device Networking Apply the above settings to CAI ports When the Application is set to Disable the relevant port will be disabled 6 28 7 Additional Serial Port Settings In this chapter we describe additional serial port settings on the CN2600 The same configuration options are also available through the telnet and serial console This chapter covers the following topics Port Communication Parameters Serial Parameters Port Data Buffering Log Port Modem Settings Welcome Message U U CU U U CN2600 Series User s Manual Additional Serial Port Setings Port Communication Parameters E Main Menu a 2 oe K o Communication Parameters CJ Overview i Basic Ked Port 1 HL Network Settings EI Serial Port Settings Port alias BG Port 1 Serial Parameters Operation Modes Baud rate Hint 115200 Gao el pata bits T z Gd Data Buffering Lo Stop bits im E CJ Modem Settings Parity None Wi i mg Ador l i eo Gale Flow control RTS CTS ae FIFO Enable Disabl Fa Enable Disable BJ Port 4 i S Port 5 Interface RS 232 Y m pi Op2 Ops Ops Ops Ore Oper Ops i cd PAK Apply the above settings to BI Port CI All ports Ports JJ Welcome Message Af System Management H System Monitoring CJ Save Configuration H Restart lt gt Port alias This optional field allows you to assign an alias to a port for easier identification Serial Parameters A
79. ap CI Mail Trap H Maintenance All ports C Mail Trap Mai Trap HG Certificate H System Monitoring CJ Save Configuration HE Restart On the Serial Event Settings page you may configure how administrators are notified of each serial port s DCD and DSR changes Mail refers to sending an e mail to a specific address Trap refers to sending an SNMP Trap DCD changed A change in the DCD Data Carrier Detect signal indicates that the modem connection status has changed For example if the DCD signal changes to low it indicates that the connection line 1s down When the DCD signal changes to low the CN2600 will automatically send a warning to the administrator as configured on the Serial Event Settings page DSR changed A change in the DSR Data Set Ready signal indicates that the data communication equipment is powered off For example if the DSR signal changes to low it indicates that the data communication equipment is powered down When the DSR signal changes to low the CN2600 will automatically send a warning to the administrator as configured on the Serial Event Settings page ATTENTION SNMP indicates a change in DCD or DSR signals but does not differentiate between the two A change in either signal from to is indicated by link up and a change in either signal from to is indicated by link down 8 8 CN2600 Series User s Manual System Management Settings E mail Alert
80. ast or multi unicast of data to one IP or groups of IP addresses The CN2600 also supports console management applications including Reverse Telnet modes Reverse terminal modes enable you to connect to a server s console port through an IP network for remote control and or monitoring of that server Device Control Applications For device control applications the CN2600 offers the following modes Real COM and RFC2217 mode 4 2 CN2600 Series User s Manual Serial Port Operation Modes Real COM Mode The CN2600 comes bundled with Real COM m drivers for Windows 98 ME NT 2000 XP 2003 Vista systems and TTY drivers for sa Linux systems In Real COM mode the bundled drivers are able to establish a transparent connection between a host and a serial device by mapping the serial port on the CN2600 to a local COM TTY port on the host computer Real COM mode supports up to 8 simultaneous connections that enable multiple hosts to simultaneously collect data from the same serial device RS 232 422 485 One of the major conveniences of using Real COM mode is that it allows you to use software that was written for pure serial communication applications The Real COM driver intercepts data sent to the host s COM port packs it into a TCP IP packet then redirects it through the host s Ethernet card At the other end of the connection the CN2600 accepts the Ethernet frame unpacks the TCP IP packet and then transparently sends the
81. ation remember to save the configuration first before upgrading the firmware Please refer to Save Configuration later in this chapter for more information Any unsaved changes will be discarded when the firmware is upgraded To upgrade the firmware simply enter the file name and click Submit The latest firmware can be downloaded at www moxa com 8 11 CN2600 Series User s Manual System Management Settings Configurating Import Export The CN2600 can share or back up its configuration by exporting all settings to a file which can then be imported into another CN2600 3p Total Solution for Industrial Device Networking J Main Menu p Overview f Basic Settings ao Network Settings Configuration Import Confiquration Import Select configuration file Browse HL Serial Port Settings Browse Ere System Management IP configuration l Import all configurations including IP configurations SIE Misc Network Settings egg Auto Warning Settings Submit 2 Ta Maintenance O Console Settings i Firmware Upgrade Sr Configuration Import Sr Configuration Export To import a configuration go to System Management gt Maintenance gt Configuration Import Enter the configuration file path name and click Submit The CN2600 s configuration settings will be updated according to the configuration file If you also wish to import the IP configuration 1 e the CN2600 s IP address netmask gateway
82. ation with the Web Console Mace This is the network interface to which the packet must be sent A ATTENTION When a serial port is configured for PPP SLIP the Iface field must be set to that serial port for proper communication Configuring Routes to the Internet 203 67 6 1 UNIX Server Ethernet SER 203 67 6 oo D T TCP IP mon n S NPort 6000 Series Router 203 67 6 253 ka 203 67 6 254 gt Modem Internet Notebook In this example the Notebook PC dials into the CN2600 to request a connection to the Internet host at 210 48 96 9 which is not on the local network 203 67 6 xxx This causes the CN2600 to act as a router and send the datagram to the default next hop router 203 67 6 254 In this case we should add the gateway IP address of 203 67 6 254 to the routing table to handle hops to 210 48 96 9 5 11 CN2600 Series User s Manual Configuration with the Web Console gt Total Solution for Industrial Device Networking Main Menu 2 Y Route Table CJ Overview a Basic Settings No Gateway Destination Netmask Metric Iface HY Network Settings R _ paan HE Serial Port Settings 1 SILI 3 S 1 255 255 255 255 ti 3 Lang ag System Management 1 lani Mi ES Misc Network Settings 3 i lani L 4 Accessible IP List 4 pi lani CJ SNMP Agent xt a
83. be transmitted after 1 additional byte is received following the delimiter e Delimiter 2 Data in the buffer will be transmitted after 2 additional bytes are received following the delimiter e Strip Delimiter Data in the buffer is first stripped of the delimiter before being transmitted Force transmit default 0 ms This parameter defines how large a gap in serial communication the CN2600 will allow before packing the serial data in its internal buffer for network transmission 6 11 CN2600 Series User s Manual Configuring Serial Port Operation Modes As data is received through the serial port it is stored by the CN2600 in the internal buffer The CN2600 transmits data stored in the buffer via TCP IP but only when the internal buffer is full or as specified by the force transmit time When set to O the force transmit time is disabled and transmission is determined solely by the data in the internal buffer At 1 to 65535 the TCP IP protocol software will pack the serial data received after there is a gap in serial communication that exceeds the specified force transmit time The optimal force transmit time depends on your application but it must be at least larger than one character interval within the specified baudrate For example assume that the serial port is set to 1200 bps 8 data bits 1 stop bit and no parity In this case the total number of bits needed to send a character is 10 bits and the time required to transfer o
84. ceeeeeeeeeeeeeeeaeeeneees 9 17 Using the NPort Monitor Utility sese sss sees 9 20 Linux Real FIY Re 9 22 Bae Procedure AA PAA ANH 9 22 Hardware RH TT 9 22 Installing Linux Real TTY Driver Files 9 22 Mapping TEY e TTT 9 23 Removing Mapped TTY Ports sese 9 23 Removing Linux Driver RI 9 24 Appendix A Appendix B Appendix C Appendix D Appendix E The UNIX Fixed TTY DriveTr 0 0000000000040090 00 aaa 9 24 Fee T the UNIX DIVER TT 9 24 Controuriae the UNIX Din vers pehidscst rows ts risawatiadeadedssonsanh Seanad we sieawetcadeelemeboniashieas 9 25 Pinouts and Cable Wiring csccccessseecccesseeceeeseeeseensseeseeenseesoneneees A 1 Port Pinout RT A 2 RS 232 422 485 Male DB9 Pinout sss aaa A 2 R5232 Mae DBO len TT A 2 RS 232 Male RJ45 Pinout sss sss ss sees sss senenn ANA GN RA A 3 RS 232 422 485 Male RJ45 Pinouts sss sss ssss sss ss vesse senenn nnn ennenen A 3 Cable Wai B aaa LAOAG Aah Nanana k adie a eeatens A 4 Ethernet C ables TET A 4 Seral Cable RS 232 kaaa tessa NA AEEA EATA A A 4 Serial Cables RS 422 4 Wire RS 485 nenen nane A 6 Serial Cables 2 Wire RS 485 J abunda naanakan g ya gs A 7 Pin Assignments for DB9 and DB25 Connectors sss eee A 8 SNMP Agent with MIB lls ssssssss sss ssss sees ees sees enean eee eenn B 1 Dynamic Domain Name Server sss ssssss esse ss esse sse esse eee seene ennenen C 1 ONCE NA ANA NG GA AN NAGA nA C 1 COME CULATION AA AA C 2 Well Known Port Numbers e
85. cified Inactivity time If this field is set to 0 the TCP connection is kept active until a connection close request is received ATTENTION If used the Inactivity time setting should be greater than the Force transmit time To prevent the unintended loss of data due to the session being disconnected it is highly recommended that this value is set large enough so that the intended data transfer is completed Max connection default 1 This field is used if you need to receive data from different hosts simultaneously When set to 1 only a single host may open the TCP connection to the serial port When set to 2 or greater up to the specified number of hosts may open this port at the same time When multiple hosts establish a TCP connection to the serial port at the same time the CN2600 will duplicate the serial data and transmit it to all the hosts Ethernet data is sent on a first in first out basis to the serial port when data comes into the CN2600 from the Ethernet interface 6 7 CN2600 Series User s Manual Configuring Serial Port Operation Modes A Ignore jammed IP default No This option determines how the port will proceed if multiple hosts are connected and one or more of the hosts stops responding as the port is transmitting data If you select No the port will wait until the data has been transmitted successfully to all hosts before transmitting the next group of data If you select Yes the port will ignore the host
86. d for the delimiter process to take place e Do Nothing Data in the buffer will be transmitted when the delimiter is received e Delimiter 1 Data in the buffer will be transmitted after 1 additional byte is received following the delimiter e Delimiter 2 Data in the buffer will be transmitted after 2 additional bytes are received following the delimiter e Strip Delimiter Data in the buffer is first stripped of the delimiter before being transmitted Force transmit default 0 ms This parameter defines how large a gap in serial communication the CN2600 will allow before packing the serial data in its internal buffer for network transmission As data is received through the serial port it is stored by the CN2600 in the internal buffer The CN2600 transmits data stored in the buffer via TCP IP but only when the internal buffer is full or as specified by the force transmit time When set to 0 the force transmit time is disabled and transmission is determined solely by the data in the internal buffer At 1 to 65535 the TCP IP protocol software will pack the serial data received after there is a gap in serial communication that exceeds the specified force transmit time The optimal force transmit time depends on your application but it must be at least larger than one character interval within the specified baudrate For example assume that the serial port is set to 1200 bps 8 data bits 1 stop bit and no parity In this case the
87. data through the serial port to the attached serial device ATTENTION Real COM mode allows several hosts to have access control over the same CN2600 The drivers that come with your CN2600 control host access by checking the host s IP address Please refer to the Accessible IP List section in Chapter 8 System Management Settings for more details RFC2217 Mode RFC 2217 mode is similar to Real COM mode That is a driver is used to establish a transparent connection between a host computer and a serial device by mapping the serial port on the CN2600 to a local COM port on the host computer RFC2217 defines general COM port control options based on the Telnet protocol Third party drivers supporting RFC 2217 are widely available on the Internet and can be used to implement Virtual COM mapping to your CN2600 serial port s Socket Applications For socket applications the CN2600 offers the following modes TCP Server TCP Client and UDP 4 3 CN2600 Series User s Manual TCP Server Mode In TCP Server mode the serial port on the CN2600 is assigned a port number which must not conflict with any other serial port on the CN2600 The host computer initiates contact with the CN2600 establishes the connection and receives data from the serial device This operation mode also supports up to 8 simultaneous connections enabling multiple hosts to collect data from the same serial device at the same time As illustrated in the figure
88. de allows you to configure the authentication mode for read write access For each level of access you may configure the following User name Use this optional field to identify the user name for the specified level of access Authentication mode default Disable Use this field to select MD5 or SHA as the method of password encryption for the specified level of access or to disable authentication Privacy mode default Disable Use this field to enable to disable DES_CBC data encryption for the specified level of access Password Use this field to set the password for the specified level of access Privacy Use this field to define the encryption key for the specified level of access Please refer t to Appendix C Dynamic Domain Name Server for information on setting up DDNS on your CN2600 Host Table gt Total Solution for Industrial Device Networking Port 9 KI Baran Host Table Port 11 Port 12 Port 13 Port 14 Port 15 Port 16 Host Name Host IP Address z o T ac E E 1 9 eL System Management EXSY Misc Network Settings Welcome Message Accessible IP List SNMP Agent DDNS Host Table Route Table Poi User Table 3 CJ Authentication Server 9 System Log Settings HE Auto Warning Settings YM Maintenance Certificate Ef System Monitoring RL Save Configuration Submit H Restart o O sy Mm NAN KH N KA The Host Table may be used to simplify IP ad
89. dial up services In addition to dial up services PPP SLIP and Dynamic the CN2600 supports RADIUS settings for terminal applications and console management application You will see it as an option for Authentication type when configuring the port s operation mode Please refer to Chapter 7 Configuring Serial Port Operation Mode for detailed information and configuration instructions Setting up UNIX Hosts MOXA recommends the FreeRADIUS server for UNIX users FreeRADIUS is the premiere open source RADIUS server and is one of the top five RADIUS servers in use world wide It 1s effective for both embedded systems with small amounts of memory and for systems with millions of users It 1s fast flexible and configurable and it supports more authentication protocols than many commercial servers The server is released under the GNU General Public License GPL which means that it is free to download and install FreeRADIUS can be downloaded from the following website http www freeradius com E 3 CN2600 Series User s Manual RADIUS Server Setting up Windows NT Hosts L 4 Install Windows NT OPTION PACK 4 0 on the Windows NT server Open Start gt Programs gt Windows NT 4 0 Option Pack gt Microsoft Internet Information Server gt Management Console Manger Accessories jlntemet Explorer E Favorites K NPort Server Pro lt Startup CN Documents gt Books Online KB Command Prompt Eh Settings DJ
90. dicate a valid connection to the Ethernet in the following ways The top right corner LED indicator maintains a solid green color when the cable is properly connected to a 100 Mbps Ethernet network The top left corner LED indicator maintains a solid orange color when the cable is properly connected to a 10 Mbps Ethernet network Connecting to a Serial Device Use appropriately wired serial data cables to connect serial devices to the CN2600 s serial ports Connecting to the Console Port A console is a combination of keyboard and monitor that is used to configure settings and monitor the status of your system The console port can be used if a network is unavailable or you do not know the CN2600 s IP address To connect to the console port use a PC running UNIX or a PC with terminal emulation software e g HyperTerminal or PComm by Moxa parameter settings are baudrate 115200 bps parity check None data bits 8 stop bits 1 terminal type VT100 Use an RJ45 to DB25 or RJ45 to DB9 cable to connect the terminal to the console port 2 3 CN2600 Series User s Manual Hardware Installation Adjustable Pull High Low Resistors for the RS 485 Port In some critical environments you may need to add termination resistors to prevent the reflection of serial signals When using termination resistors it is important to set the pull high low resistors correctly so that the electrical signal is not corrupted The
91. dress entry on the CN2600 console by assigning a Host Name to a Host IP Address When you assign a Host Name to a Host IP Address you may then use the Host Name for some fields on the console rather than entering the IP address Up to 16 entries can be stored on the Host Table 8 4 CN2600 Series User s Manual System Management Settings User Table NPort Web Console Microsoft Internet Explorer O2 SSS NPort Web Console Microsoft Internet NPort Web Console Microsoft Internet Explorer O2 SSS SIG x File Edit View Favorites Tools Help Q Back gt te Ee a LJ ip Address E http 192 168 127 254 E KJ co Total Solution for Industrial Device Networking 8G Porto B Port 10 BG Port11 B Port 12 B Port 13 B Port 14 BG Port 15 BG Port 16 C9 Welcome Message User Table User Name Password Phone Number zZ o oo System Management so Misc Network Settings CJ Accessible IP List 5 CJ SNMP Agent 3 G3 DDNS a Host Table fa Route Table I User Table E Authentication Server 9 System Log Settings o Auto Warning Settings Gia Maintenance Certificate ae System Monitoring o oOo N Oo NA fF U N re N Save Configuration Restart The CN2600 User Table may be used for to authenticate users for terminal or reverse terminal access and is useful if you do not have an external RADIUS server for authentication The CN2600 User Table stores up to 64 entries w
92. driver only provides a pure data tunnel no control ability The serial port parameters will use firmware settings instead of depending on your application program AP Application software that is based on the COM driver will receive a driver response of success when the software uses any of the Win32 API functions The firmware will only send data back to the driver on the host Data will be sent first in first out when data comes into the CN2600 from the Ethernet interface ATTENTION When Max connection is greater than 1 the CN2600 will use a multi connection application 1 e 2 to 4 hosts are allowed access to the port at the same time When using a multi connection application the CN2600 will use the serial communication parameters as defined here in the web console and all hosts connected to the port must use identical serial settings If one of the hosts opens the COM port with different serial settings data will not be transmitted properly Ignore jammed IP default No This option determines how the port will proceed if multiple hosts are connected and one or more of the hosts stops responding as the port is transmitting data If you select No the port will wait until the data has been transmitted successfully to all hosts before transmitting the next group of data If you select Yes the port will ignore the host that stopped responding and continue data transmission to the other hosts Allow driver control default N
93. e Login password Apply the above settings to Terminal lt Terminal TERM ASC 7 0 99 min 0 0 99 min None w 23 ansi dN ST AE None w ogin assword P1 pe ips CIP4 OPs O P6 C P7 Ces Call ports nG lt gt TCP alive check time default 7 min This field specifies how long the CN2600 will wait for a response to keep alive packets before closing the TCP connection The CN2600 checks connection status by sending periodic keep alive packets If the remote host does not respond to the packet within the time specified in this field the CN2600 will force the existing TCP connection to close For socket and device control modes the CN2600 will listen for another TCP connection from another host after closing the connection If TCP alive check time is set to 0 the TCP connection will remain open even if there is no response to the keep alive packets Inactivity time default 0 min This field specifies how long the CN2600 will wait for incoming and outgoing data through the serial port before closing the TCP connection The TCP connection is closed if there is no incoming or outgoing data through the serial port for the specified Inactivity time If this field is set to 0 the TCP connection is kept active until a connection close request is received 6 20 CN2600 Series User s Manual Configuring Serial Port Operation Modes ATTENTION Inactivity time should at least be set
94. e COM port for the connection COM1 in this example Configure the baudrate for either 460800 230400 115200 57600 38400 19200 or 9600 and then press OK I x Communication Parameter Terminal File Transfer Capturing m COM Options Pots Baud Rate 19200 Data Bits a x Parity None Stop Bits fi L m Flow Control p Output State P RTSATS DTR ON 1 OFF FP XONAXOFF RTS ON C OFF Cancel 5 From the Property window s Terminal page select ANSI or VT100 for Terminal Type and click OK 6 Press lt Enter gt key to bring out the console screen If the CN2600 has been set up for password protection you will be prompted to enter the password After you enter the password or if password protection was not enabled you will be prompted to select the terminal mode Press 1 for ansi vt100 and then press ENTER EB COM4 115200 Hone 8 1 Dnmli Terminal Terminal Server CN2650 8 2AC Console terminal type il amsi swtlO0 Z vt5 z 1 3 10 CN2600 Series User s Manual Initial IP Address Configuration 7 The main menu should come up Once you are in the console you may configure the IP address through the Network menu item just as with the Telnet console Please refer to steps 4 to 11 in the Telnet Console section to complete the initial IP configuration CL E COM4 115200 Hone 8 1 ANSI 3 CNZ650 8 2ac O 1 0 DTR Overview Basic NESE a Port System Monitor lt he Festart
95. e eeee eenn neee D 1 RADIUS SENG a ANNA E 1 KA T AS RADIS raran KNA BANNA NAA AA cious AA E 2 PCT Se E 2 CHIEU S CEVER EH La TT E 2 SECS Up NECN 2 GOO T E 2 Setting up the RADIUS Server IP AddreSS sss E 2 Sela PO RET EE ALON maa AA AA CABAGAN E 3 Sime UNIX HOS RTT E 3 Sene Up Windows NT HOSI E E taut E 4 Seneu Windows 2000 HOSS naaa a NAA ma NBA E 6 Sette Wp Window si2 O03 HOSTS T E 9 1 Introduction Moxa s CN2600 series of dual LAN terminal servers is available in models with 8 or 16 RS 232 or RS 232 422 485 ports and all models come with two 10 100 Mbps Ethernet LAN ports The CN2600 duaI LAN terminal servers are used to connect terminals modems printers and other asynchronous serial devices to LAN hosts The CN2600 dual LAN terminal servers comply with TCP IP and IEEE 802 3 specifications using standard Ethernet 10 100BaseT and twisted pair 10 100BaseTX cable as the data transmission medium NOTE In this manual we often refer to all terminal servers in the CN2600 series collectively as the CN2600 NOTE The wide temperature model does not have an LCM Display panel and push buttons The LCM description in this manual applies only to standard temperature models The following topics are covered in this chapter LJ Product Features gt Hardware gt Software Package Checklist Front Panel Rear Panel Bottom Label m e a CN2600 Series User s Manual Introduction Product Features Hardware e Dual LAN ports
96. e of the tools described in this chapter e If your CN2600 terminal server is used in a dynamic IP environment the IP address will be assigned automatically from over the network In this case set the IP configuration mode to DHCP DHCP BOOTP BOOTP or PPPoE A ATTENTION Consult your network administrator on how to reserve a fixed IP address for your CN2600 in the MAC IP mapping table when using a DHCP Server or BOOTP Server For most applications you should assign a fixed IP address to your CN2600 Factory Default IP Address The CN2600 is configured with the following default private IP addresses 192 168 126 254 and 192 168 127 254 Note that IP addresses that begin with 192 168 are referred to as private IP addresses Devices configured with a private IP address are not directly accessible from a public network For example you would not be able to ping a device with a private IP address from an outside Internet connection If your application requires sending data over a public network such as the Internet your CN2600 will need a valid public IP address which can be leased from a local ISP Configuration Options Terminal Server Search Utility You may configure your CN2600 with the bundled NPort Search Utility for Windows Please refer to Chapter 9 Software Installation Configuration for details on how to install and use Terminal Server Search Utility Web Console You may configure your CN2600 using a standard web
97. e that you have selected CN2600 Series User s Manual Configuring Serial Port Operation Modes Device Control Applications Real COM Mode MOXA SY Main Menu 3 A ka A Operation Modes LI Overview CJ Basic Settings Port 1 9 Network Settings v b atio Device Contro v EN Serial Port Settings adan 3 l Gg parr 1 Mode RealCOM E Operation Modes TCP alive check time 7 0 99 min CJ Communication P Max connection 1 3 9 Data Buffering Lo Ignore jammed IP Enable Disable ip s J Modem Settings Allow driver control Enable Disable an Port 2 Connection goes down RTS Oalways low always high Ha Port 2 DTR O always low always high HG c YA Port 4 Data Packing nG rate Packet th O b d acket len 0 BG Port g 0 1024 0G Pot 7 Delimiter 1 00 Hex Cl Enable eo Port 8 Delimiter 2 00 Hex Cl Enable BP CJ Welcome Message Delimiter process Do Nothing Y Processed only when Packing length is 0 CJ System Management Force transmit 0 0 65535 ms d ah ER Syster Manikang pi Ope Ops Er Ops Ore pr Ope CJ Save Configuration Apply the above settings to ies E CJAII ports T Restart v w R multiple hosts Real COM drivers open the port at the same time the COM driver only provides a pure data tunnel no control ability The serial port parameters will use firmware settings instead of depending on your application program AP Application software that 19 based on the COM driver will
98. ea Serial Port Settings o System Management _ submit Ae Misc Network Settings Ba 4uto Warning Settings Be Maintenance EMEY Certificate Ethernet SSL Certifica Gi Certificate Key Delete aE System Monitoring o Save Configuration Bi Restart Certificate Key Delete SSL certificate Delete keep 8 14 CN2600 Series User s Manual System Management Settings System Monitoring Serial to Network Connections Go to Serial to Network Connections under Serial Status to view the operation mode and status of each connection for each serial port All monitor functions will refresh automatically every 5 seconds gt Total Solution for Industrial Device Networking E Main Menu Serial to Network Connections CJ Overview im Basic Settings Ml Auto refresh S Network Settings Port OP Mode Connections kd mm serial Port Settings Y system Management sa System Monitoring 2 Device Control RealCOM SI Serial Status 1 Device Control RealCOM Pl Jl 9 k JI pit igi Jl Jl As NT HI VE PE TA LS Satial to Network Ge 3 Device Control RealCOM IC IC ji a Serial Port Status 4 Device Control RealCOM Jl Vt E 199 Serial Port Error Cav 1 L 1 l I T 0 Serial Port Settings lt Device Control RealCOM ae System Status 3 pit 1 Tt ea Save Configuration S ST L HE lf tL GQ Restart h PE JI d esta 7 Device Control RealCOM it Wa II i hit LI
99. ed local ports Connection control default Startup None This setting determines the parameters under which a TCP connection is established or disconnected The different options are given in the following table In general both the Connect condition and Disconnect conditions are given 6 10 CN2600 Series User s Manual A Configuring Serial Port Operation Modes A TCP connection will be established on startup and will remain active indefinitely A TCP connection will be established when any character is received from the serial interface and will remain active indefinitely Any Character A TCP connection will be established when any character is received Inactivity Time from the serial interface and will be disconnected when Inactivity time is reached DSR On DSR Off A TCP connection will be established when a DSR On signal is received and will be disconnected when a DSR Off signal is received DSR On None A TCP connection will be established when a DSR signal of NPort is On and will remain active indefinitely DCD On DCD Off A TCP connection will be established when a DCD On signal is received and will be disconnected when a DCD Off signal is received DCD On None A TCP connection will be established when a DCD On signal is received and will remain active indefinitely Packet length default 0 This field refers to the maximum amount of data that is allowed to accumulate in the se
100. efault No If this field is set to Yes the CN2600 will store data logs on the system RAM for all serial ports Note that this data is not saved when the CN2600 is powered off Each serial port is allotted 128 KB to store that port s log file Port Modem Settings 4 Main Menu pi CJ Overview RG Basic Settings ag Network Settings Ae Serial Port Settings 0G Port 1 E CJ Operation Modes 3 CJ Communication P CJ Data Buffering Lo J Modem Settings pig Port 2 G Port3 BA Part4 Modem Settings Port 1 Enable modem O Enable Disable Initial string Dial up JAT Phone number P1 p2 OPs CO P4 OPs Ci P6 CP Cips Apply the above settings to ClAll ports Modem settings are used for the Dial In Out modes These settings will have no effect on ports configured for other modes Enable modem default Disable 7 3 CN2600 Series User s Manual Additional Serial Port Setings Initial string Use this field to configure the initial string that the modem will use to establish the connection For example AT amp S0 1 for auto answer Dial up Use this field to configure the modem s Dial up AT command string Phone number Use this field to configure the number that the user uses to dial out Welcome Message gt Total Solution for industrial Device Networking E Main Menu ei Overview i Basic Settings H Network Settings nog Serial Port Settings Enable welcome
101. epends on whether the remote user s application requests compression Inactivity time default 0 ms This field specifies the idle time setting for auto disconnection A setting of O ms will cause the port to remain connected even if idle Link quality report default No Setting this field to Yes allows the CN2600 to disconnect a connection if the link noise exceeds a certain threshold Outgoing PAP ID This is the dial out user ID account PAP password This is the dial out user password Incoming PAP check default None This field allows you to configure the method used if any to verify a user s ID and authorization Local Verify the ID against the CN2600 User Table RADIUS Verify the ID against the external RADIUS server Authentication is not required Disconnect by default None If this field is set as DCD off the connection will be disconnected when the DCD signal is off If this field is set as DSR off the connection will be disconnected when the DSR signal is off PPPD Mode 4 Main Menu A HE Overview Operation Modes E Basic Settings ao Network Settings Port 1 EM Serial Port Settings Application Dial infout v IT Port 1 Mode PPPD CI Operation Modes Destination IP address CJ Communication P LES Source IP address Li Data Buffering La id s IP netmask 5 CI Modem Settings er eg Port 2 TCP IP compression O Enable Disable aE Port 3 Inactivity time iO O 65535 ms
102. er Setting up Windows 2003 Hosts Windows 2003 uses the IAS service instead of the RADIUS service For this reason you need to install the IAS service to use RADIUS with Windows 2003 The IAS service will not be installed by default 1 Open Start gt Add or Remove Programs gt Add Remove Windows Components 2 With Windows Components selected choose Networking Services Windows Components Wizard f Windows Components TOU can add or remove components of Windows To add of remove a component click the checkbox A shaded box means that only part of the component will be installed To see what s included in a component click Details Components O LR Management and Moritoring Tools E i x 7 ter oe NTT TR LI i Other Network File and Print Services DOMB J L Remote Installation Services 2 0 MB C 4 Remnhe Storane JAMA Description Contains a variety of specialized network related services and protocols Total disk space required 17 2 MB eee Space available on disk 1914 9 ME lt Back Cancel Help 3 Select Details and then select Internet Authentication Service Continue clicking OK until the installation is complete Networking Services x To add or remove a component click the check box A shaded box means that only part of the component will be installed To see what s included in a component click Details Subcomponents of Metworking Services O z Domain Name System DNS O m D
103. etc make sure that Import all configurations including IP configurations is checked off 9 Total Solution for Industrial Device Networking SY Main Menu a ee mye Configuration Export a Basic Settings ag Network Settings ao Serial Port Settings ES System Management Download Cia Misc Network Settings tA Auto Warning Settings ea Maintenance i d Console Settings CJ Firmware Upgrade Configuration Export oe Configuration Import MG Configuration Export a Load Factory Default _ CJ Change Password 49 Certificate ea System Monitoring To export a configuration go to System Management gt Maintenance gt Configuration Export and click Download A standard download window will appear and you will be able to download the configuration into a file name and location of your choice 8 12 CN2600 Series User s Manual System Management Settings Load Factory Defaults gt Total Solution for Industrial Device Networking SI Main Menu CI Overview 8 Basic Settings Click on Submit to reset all settings including the console password to the factory default Hi values To leave the IP address netmask gateway and WLAN profile settings unchanged CJ Network Settings make sure that Keep IP Settings is enabled HE Serial Port Settings Load Factory Default 724 System Management Reset to Factory Default H Misc Network Settings SIE Auto Warning Settings M Keep IP settings B
104. etermining network distance Other protocols use more sophisticated algorithms that also include timing After receiving a packet headed for a specific destination a network host with a router uses the routing table information to determine the next host to route 5 9 CN2600 Series User s Manual Configuration with the Web Console the packet to RIP is considered an effective solution for small homogeneous networks For larger more complicated networks transmitting the entire routing table every 30 seconds can bog down the network with a lot of extra traffic RIP 2 is an extension of RIP Its purpose is to expand the amount of useful information contained in RIP packets and to add security elements RIP 2 has become the standard version of RIP and the original RIP is no longer used Routing Protocol You may select which routing protocol if any your network will employ Gratuitous ARP In some applications you may need the CN2600 to send broadcast packets to update the ARP table on the server If you enable this function and set the send period the CN2600 will send periodically send broadcast packets at the specified time interval Configuring the Route Table You can access the Route Table by expanding System Management and then Misc Network Settings in the navigation panel The route table is where you configure how the CN2600 will connect to an outside network hey Mann Manu wa T Romi Talile J Overview LI Basit Set
105. field to have effect If Delimiters 1 and 2 are both enabled both characters must be received for the delimiter process to take place e Do Nothing Data in the buffer will be transmitted when the delimiter is received e Delimiter 1 Data in the buffer will be transmitted after 1 additional byte is received following the delimiter e Delimiter 2 Data in the buffer will be transmitted after 2 additional bytes are received following the delimiter e Strip Delimiter Data in the buffer is first stripped of the delimiter before being transmitted Force transmit default 0 ms This parameter defines how large a gap in serial communication the CN2600 will allow before packing the serial data in its internal buffer for network transmission As data is received through the serial port it is stored by the CN2600 in the internal buffer The CN2600 transmits data stored in the buffer via TCP IP but only when the internal buffer is full or as specified by the force transmit time When set to O the force transmit time is disabled and transmission is determined solely by the data in the internal buffer At 1 to 65535 the TCP IP protocol software will pack the serial data received after there is a gap in serial communication that exceeds the specified force transmit time The optimal force transmit time depends on your application but it must be at least larger than one character interval within the specified baudrate For example assume that
106. figure remote facilities and equipment over the Internet from anywhere in the world Traditional SCADA and data collection systems rely on serial ports to collect data from various kinds of instruments Since the CN2600 network enables instruments equipped with an RS 232 RS 422 or RS 485 communication port your SCADA and data collection system will be able to access all instruments connected to a standard TCP IP network regardless of whether the devices are used locally or at a remote site The CN2600 is an external IP based network device that allows you to expand the number of serial ports for a host computer on demand As long as your host computer supports the TCP IP protocol you will not be limited by the host computer s bus limitation such as ISA or PCI nor will you be limited by the absence of drivers for various operating systems In addition to providing socket access the CN2600 also comes with a Real COM TTY driver that transmits all serial signals intact This enables you to preserve your existing COM TTY based software without needing to invest in additional software Three different socket modes are available TCP Server TCP Client and UDP Server Client The main difference between the TCP and UDP protocols is that TCP guarantees delivery of data by requiring the recipient to send an acknowledgement to the sender UDP does not require this type of verification making it possible to offer faster delivery UDP also allows unic
107. full or as specified by the force transmit time When set to O the force transmit time is disabled and transmission is determined solely by the data in the internal buffer At 1 to 65535 the TCP IP protocol software will pack the serial data received after there is a gap in serial communication that exceeds the specified force transmit time The optimal force transmit time depends on your application but it must be at least larger than one character interval within the specified baudrate For example assume that the serial port is set to 1200 bps 8 data bits 1 stop bit and no parity In this case the total number of bits needed to send a character is 10 bits and the time required to transfer one character is 10 bits 1200 bits s x 1000 ms s 8 3 ms Therefore you should set the force transmit time to be larger than 8 3 ms so in this case it must 6 4 CN2600 Series User s Manual Configuring Serial Port Operation Modes be greater than or equal to 10 ms If it is necessary to send a series of characters in the same packet the serial device will need to send that series of characters within the specified force transmit time and the total length of data must be less than or equal to the CN2600 s internal buffer size 1 KB per port RFC2217 Mode O Main Menu CJ Overview Gg Basic Settings ALI Network Settings Operation Modes Port 1 icati i N Aa Sapa Back Serene Application Device Control BS Po
108. g Setup NPort Windows Driver Manage oj x Insta pi Software Installation AN The software you are installing has not passed Windows Logo testing to verify its compatibility with Windows XP Tell hi this testing is important I Continuing your installation of this software may impair either immediately or in the future Microsoft strongly recommends that you stop this installation now and Continue Anyway STOP Installation CN2600 Series User s Manual Software Installation Configuration 7 Click Finish to complete the installation of the CN2600 Windows Driver Manager Z Setup NPort Windows Driver Manager el Es Completing the NPort Windows Driver Manager Setup Wizard Setup has finished installing NPor Windows Driver Manager on your computer The application may be launched by selecting the installed icons Click Finish to exit Setup IZ Launch NPort Windows Driver Manager Using NPort Windows Driver Manager After you install the NPort Windows Driver Manager you can set up the CN2600 s serial ports as remote COM ports for your PC host Be sure the serial port s on your CN2600 are set to Redundant COM mode when using NPort Windows Driver Manager to map COM ports 1 Goto Start gt CN2600 series Windows Driver Manager gt CN2600 series Windows Driver Manager to start the COM mapping utility 2 Click the Add icon 2 NPort Windows Driver Manager x File COM Mapping View Help
109. gging in as root enter the directory usr lib npreal2 driver and then execute mxdelsvr to delete a server The syntax of mxdelsvr is mxdelsvr P Address Example cd usr lib npreal2 driver 9 23 CN2600 Series User s Manual Software Installation Configuration mxdelsvr 192 168 3 4 The following actions are performed when executing mxdelsvr 1 Modify npreal2d cf 2 Remove the relevant tty ports in directory dev 3 Restart the driver If the IP address is not provided in the command line the program will list the installed servers and total ports on the screen You will need to choose a server from the list for deletion Removing Linux Driver Files A utility is included that will remove all driver files mapped tty ports and unload the driver To do this you only need to enter the directory usr lib npreal2 driver then execute mxuninst to uninstall the driver This program will perform the following actions 1 Unload the driver 2 Delete all files and directories in usr lib npreal2 3 Delete directory usr lib npreal2 4 Modify the system initializing script file The UNIX Fixed TTY Driver Installing the UNIX Driver 1 Log in to UNIX and create a directory for the MOXA TTY To create a directory named usr etc execute the command mkdir p usr etc 2 Copy moxattyd tar to the directory you created If you created the usr etc directory above then execute the following commands cp moxattyd ta
110. gin using this function E 10
111. h Utility on your computer Click Install to continue with the installation or click Back if Vou want to review or change any settings Destination location C Program Files WPortSearch Start Menu folder MPort Search Utility G Lancel 6 Click Install to begin the installation The setup window will report the progress of the installation To change the installation settings click Back and navigate to the previous screen 9 3 CN2600 Series User s Manual Software Installation Configuration 7 Click Finish to complete the installation of Terminal Server Search Utility ie setup MPort Search Utility Completing the NPort Search Utility Setup Wizard Setup has finished installing NPort Search Utility on pour computer The application may be launched by selecting the installed icons Click Finish to exit Setup Configuring NPort Search Utility The Broadcast Search function is used to locate all CN2600 servers that are connected to the same LAN as your computer After locating a CN2600 you will be able to change its IP address Since the Broadcast Search function searches by MAC address and not IP address all CN2600 servers connected to the LAN will be located regardless of whether or not they are part of the same subnet as the host 9 4 CN2600 Series User s Manual Software Installation Configuration 1 Open NPort Search Utility and then click the Search icon lS NPort Search Utility
112. he installation To change the installation settings click Back and navigate to the previous screen 3 Setup NPort Monitor Utility Heady to Install Setup is now ready to begin installing NPort Monitor Utility on your computer Click Install to continue with the installation or click Back if uou want to review or change any settings Destination location C Program Kiez N Porth onitor Cancel 9 19 CN2600 Series User s Manual Software Installation Configuration 6 Click Finish to complete the installation of the NPort Monitor Utility fe Setup NPort Monitor Utility Completing the NPort Monitor Utility Setup Wizard Setup has finished installing N Port Monitor Utility on your computer The application may be launched by selecting the Installed icons Click Finish to esit Setup Finish Using the NPort Monitor Utility After you install the NPort Monitor Utility you can monitor the status of the IP address and MAC address for redundant LAN 1 and also for redundant LAN 2 1 Goto Start gt NPort Monitor Utility to start the monitor utility 2 Click the Search icon LS NPort Monitor Utility Function Run Help il K Exit Search Srat Stop Bb erer List MAC Address IP Address 9 20 CN2600 Series User s Manual Software Installation Configuration 3 Click Rescan to search for CN2600 terminal servers From the list that is generated select the server that you wi
113. he IP netmask defines the netmask also known as the subnet mask for the SLIP connection 6 26 CN2600 Series User s Manual Configuring Serial Port Operation Modes TCP IP compression default No The setting of this field depends on whether the remote user s application requests compression Inactivity time default 0 ms This field specifies the idle time setting for auto disconnection A setting of O ms will cause the port to remain connected even if idle Disconnect by default None If this field is set as DCD off the connection will be disconnected when the DCD signal is off If this field is set as DSR off the connection will be disconnected when the DSR signal is off SLIPD Mode 4 Main Menu CI Overview Operation Modes a Basic Settings Network Settings Port 1 gt E Serial Port Settings Application Dial infout v Titia Mana Supp lt _ Cl Operation Modes Destination IP address arang a ETT Source IP address i i gd Data Buffering Lo Et BA aY ee IP netmask CJ Modem Settings 3 ig E i o Dn egg Port 2 TCP IP compression O Enable Disable AE Port 3 Inactivity time oO 0 65535 ms aE Port 4 Disconnect by None ff AG port 5 diad SPEE pi Ore p3 Or Oms Or Orr Ops i pply the above settings to i ao Port 6 Call ports OO Port 7 BJ Port8 CJ Welcome Message ae System Management H System Monitoring CJ Save Configuration HE Restart lt gt SLIPD SLI
114. iguration LANZ IP address LANZ Netmask LANZ Gateway LANZ speed LAN2 PPPoE user account LANZ PPPoE password DNS server 1 DMS server 2 WINS function WINS server 192 168 686 182 255 255 255 0 L LHut o Static 192 168 126 254 255 255 455 0 Auto Enable 1 6 Press ESC twice to return to the previous page Press Y to confirm the modification N2650 8 2AC Advanced Quit BSE CH2650 8 2AC_H 1 8 Examine modify basic network settings Enter select ESC previous menu Warning tt You have modified the configuration without saving Would you save it now Y yes 7 Press ESC to return to the previous page 3 7 CN2600 Series User s Manual Initial IP Address Configuration 8 Press A or use the arrow keys to select Save and then press ENTER Press ENTER again to confirm the save command E BEE CN2658 8 2AC_ 1 8 ITE TT Basic Network Port System Monitor sve Restart Exit Save current configuration to flash ROM ESC back to menu Enter select 9 Press R or use the arrow keys to select Restart and then press ENTER E EI CN265 8 2AC_ 1 0 IS TTT T KAN O EE T Pe a a LU Restart EEA Restart the whole system or selected serial ports Enter select ESC previous menu 3 8 CN2600 Series User s Manual Initial IP Address Configuration 10 Press S or use the arrow keys to select System and then press ENTER to restart the CN2600 oe
115. ing RS 232 Male RJ45 Pinouts EEEE 1 8 KE Cs PTR out RS 232 422 485 Male RJ45 Pinouts MITT T TT 1 8 RS 422 PIN RS 232 RS 485 4W RS 485 2W 1 DSR 2 RTS TxD B 3 GND GND GND 4 TXD TxD A 5 RXD RxD B Data B 6 DCD RxD A Data A 7 CTS S DTR A 3 CN2600 Series User s Manual Pinouts and Cable wiring Cable Wiring Diagrams Ethernet Cables Straight Through Cable NG Ti RJ45 Plug Pin 1 ME Cable Wiring N QO L N QO L Cross Over Cable NG T RJ45 Plug Pin 1 IE Cable Wiring N O L DM AN Serial Cables R5 232 RJ45 8 pins to Female DB9 RJ45 Port RJ45 Connector Female DB9 Male DB9 ET RS 232 8 pins Cable Wiring 9 pins DSR 1 4 DTR RTS 2 8 CTS GND 3 _ 5 GND TxD 4 ______ gt 2 RD RD 5A 3 TxD DCD 6 lt 1 DCD CTS 7 lt ____Y7 RTS DIR 8 6 DSR A 4 CN2600 Series User s Manual Pinouts and Cable wiring RJ45 8 pins to Male DB9 RJ45 Port RJ45 Connector Male DB9 3 Female DB9 Fi zm RS 232 8 pins Cable Wiring 9 pins DSR 1 6 DTR RTS 2 7 CTS GND 3 5 GND TxD 4 3 RxD RxD 5 2 E TxD DCD 6 lt
116. inga AI Network Settings s v z Server name CN2650 8 2AC_0 EN Serial Port Settings HE Port 1 Server location ae Port 2 Time Settings HA Port 3 Time zone 24 hour GMT Greenwich Mean Time Dublin Edinburgh Lisbon London HE Port 4 Local time 2000 ji y2 14 l59 15 Modify ET ii S Port s Time server BG Port 6 BG port 7 80 porte O Welcome Message BC System Management HE System Monitoring CJ Save Configuration HH Restart Server name This is an optional free text field for your own use it does not affect operation of the CN2600 It can be used to help differentiate one CN2600 server from another Server location This is an optional free text field for your own use it does not affect operation of the CN2600 It is useful for assigning or describing the location of a CN2600 In a network environment of multiple servers this can be a valuable aid when performing maintenance Time Settings The CN2600 has a built in Real Time Clock for time calibration functions Functions such as Auto Warning Email or SNMP Trap can add real time information to messages Before making any adjustments to the time first select the correct time zone and submit the change The console will display the real time according to the time zone To modify the real time clock click on Modify next to the Local time field Once you submit the new time the CN2600 s firmware will modify the GMT time according to your time zone and
117. ings when the CN2600 is powered on However the program can redefine the serial parameters to different values after the program opens the port via Win 32 API COM Port Setting E 0 x Port Number 1 Port s are Selected Basic Settings Advanced Settings Serial Parameters Security FP Aol Selected Ports FT hese options will be saved on registry and used on few applications such as serial printer driver In general case You can ignore these settings Baud Rate asn i itt Parity None Data Bits ls g Stop Bits i 9 Flow Control None 11 Click the Security tab to configure security settings Select the Enable Data Encryption option to enable data to be encrypted when transmitted over the COM ports After selecting the encryption option select the Keep connection option to start encrypting COM port communications immediately without restarting the COM ports If your application will open close a COM port frequently and the CN2600 1s only used for one host you can enable this option to speed up the opening closing time However this will result in your host tying up the COM port so that other hosts cannot use it Select the Apply All Selected Ports option to enable the security settings to be applied to all COM ports z COM Port Setting Port Number 1 Port z are Selected Basic Settings Advanced Settings Serial Parameters Security PU Appl AlliSelected Ports F Enable Date Encyphen E keep Gonnech
118. ions on adding the site to the local intranet zone instead Important adding this web site to the Trusted sites zone will lower the security settings for all content from this web site for all applications including Internet Explorer You may also directly access the list of trusted sites through Internet Options in the Tools menu of Internet Explorer Select the Security tab then click on the Trusted Sites icon and on the Sites button General Security Privacy Content Connections Programs Advanced Select a Web content zone to specify its security settings 8 amp Internet Local intranet Restricted sites Trusted sites Trusted sites This zone contains Web sites that you Sites trust not to damage your computer or data Security level for this zone Custom Custom settings To change the settings click Custom Level To use the recommended settings click Default Level Custom Level Default Level Cancel Apply 2 In either case the window below should appear showing the list of sites that you have configured Internet Explorer to trust Add the IP address of your CN2600 here the factory default LANI IP address is 192 168 127 254 and default LAN2 IP address is 192 168 126 254 5 3 CN2600 Series User s Manual Configuration with the Web Console You can add and remove Web sites From this zone All Web sites in this zone will use the zone s securit
119. ith fields for User Name Password and Phone Number CN2600 Series User s Manual System Management Settings Authentication Server ENT Internet anire File Edit view Favorites Tools Help CO pad x 3 x E Ti p Search iy Favorites o o E L Ss Address le http 192 168 127 254 lt EJ co 1915 Total Salutjon for industrial Device Natwarking BJ Porto S aa ST Port 10 Authentication Server B03 Port 11 A T1 Configuration ENG Port 12 Gy Por13 RADIUS server IP ngg port 14 RADIUS key ar acy Port 15 UDP port 1645 7 BG Port 16 RADIUS accounting C Enable Disable E Welcome Message ES System Management mapa Z SI Misc Network Settings H Accessible IP List CJ SNMP Agent 3 prus A Host Table a Route Table g5 User Table A Authentication Server E B System Log Settings HH Auto Warning Settings RADIUS server IP If you are using a RADIUS server for user authentication enter its IP address here RADIUS key If you are using a RADIUS server for user authentication enter its password here UDP port default 1645 If you are using a RADIUS server enter its UDP port assignment here RADIUS accounting Use this field to enable or disable RADIUS accounting System Log Settings No Total Solution tor Industrial Device Networking J Main Menu Syst Loo Betti stem Log Settings Overview N k CJ Basic Settings Event Group Local Log Summary H Network Setu
120. key for program termination Authentication type default None This field allows you to configure the method used if any to verify a user s ID and authorization Verify the ID against the CN2600 User Table RADIUS Verify the ID against the external RADIUS server Authentication is not required Auto login prompt default ogin Password prompt default assword Login user name Enter the terminal login ID here Login password Enter the password for the terminal login here 6 21 CN2600 Series User s Manual Terminal BIN TERM BIN Vireo SI Main Menu CJ Overview SE Basic Settings HE Network Settings SY Serial Port Settings BG Poti 35 J Operation Modes CJ Communication P piga Data Buffering Lo A CJ Modem Settings BC Port2 B Port 3 OC Port4 BG Ports G Port 6 BG Port7 XO Ports CJ Welcome Message aa System Management HE System Monitoring CJ Save Configuration HE Restart lt gt Operation Modes Port 1 Application Mode TCP alive check time Inactivity time Auto link protocol Primary host address Secondary host address Telnet TCP port Terminal Terminal type Quit Authentication type Automatic Login Auto login prompt Password prompt Login user name Login password Apply the above settings to Configuring Serial Port Operation Modes Terminal v Terminal TERM BIN 7 0 99 min 0 0 99 min None 23 ansi PE
121. l COM mode 2 Install the Linux Real tty driver files on the host 3 Map the NPort serial port to the host s tty port Hardware Setup Before proceeding with the software installation make sure you have completed the hardware installation Note that the default IP address for the CN2600 is 192 168 127 254 NOTE After installing the hardware you must configure the operation mode of the serial port on your CN2600 to Real COM mode Installing Linux Real TTY Driver Files 1 Obtain the driver file from the included CD ROM or the MOXA website at http www moxa com Log in to the console as a super user root Execute cd to go to the root directory Copy the driver file npreal2xx tgz to the directory Execute tar xvfz npreal2xx tgz to extract all files into the system Execute tmp moxa mxinst a O For RedHat AS ES WS and Fedora Corel append an extra argument as follows tmp moxa mxinst SP1 9 22 CN2600 Series User s Manual Software Installation Configuration The shell script will install the driver files automatically 7 After installing the driver you will be able to see several files in the usr lib npreal2 driver folder gt mxaddsvr Add Server mapping tty port gt mxdelsvr Delete Server un mapping tty port gt mxloadsvr Reload Server gt mxmknod Create device node tty port gt mxrmnod Remove device node tty port gt mxuninst Remove tty port and driver files At this point you
122. ll force the existing TCP connection to close For socket and device control modes the CN2600 will listen for another TCP connection from another host after closing the connection If TCP alive check time is set to 0 the TCP connection will remain open and will not send any keep alive packets Ignore jammed IP default No This option determines how the port will proceed if multiple hosts are connected and one or more of the hosts stops responding as the port is transmitting data If you select No the port will wait until the data has been transmitted successfully to all hosts before transmitting the next group of data If you select Yes the port will ignore the host that stopped responding and continue data transmission to the other hosts Primary IP address The primary host s IP address If left blank then every host on the network cannot access the serial port Backup 1 IP address Backup host s IP address Backup 2 IP address Backup host s IP address Backup 3 IP address Backup host s IP address Connection goes down default always high You can configure what happens to the RTS and DTR signals when the Ethernet connection goes down For some applications serial devices need to know the Ethernet link status through RTS or DTR signals sent through the serial port Use goes low if you want the RTS and DTR signal to change their state to low when the Ethernet connection goes down Use always high if you do not want the Ethernet c
123. ll monitor and then click OK Searching N Pois Searching Found 1 NPort s remaining 4 seconds Model MAC address 1 Ki CH2610 16 00 90 E82 0E F4 0E 19216222118 00 50 E 2 0E F4 0F 192 168 356 188 x Cancel 4 The monitoring information will appear on the Monitoring page Select the IP address from the left hand side that you would like to monitor and then click the Start icon CS Bort Monitor hry Fil 2 2 kat Sez SoablvIP Shai C H Tarh Un z x tig Dehe Seling a VSL Lah VP VE Sir Idie Heedet CHa mm Poder Te 194 TER 9 185 HAD Adhere GUSLEROE FADE HERE FLF Parnecbcan Li nie Genre arena 3 Cime 1 5 The status will be listed as On Line which means that all of the port numbers with LAN 1 and LAN 2 IP addresses will appear on the page If your maximum connections is 2 the monitor s connection 2 will show the LAN IP address 9 21 CN2600 Series User s Manual Software Installation Configuration Bi Na a Lina Model CNZEIG YE Earn TAg D 197 TEH 1 HAD Adder HII EREE ELIE GSES E HA IE I isat tail Laret 1 reena T paeen Linux Real TTY Drivers Basic Procedures Follow these instructions to map a CN2600 serial port to a Linux host s tty port 1 Set up the CN2600 After verifying that the IP configuration works and you can access the CN2600 by using ping telnet etc configure the desired serial port on the CN2600 to Rea
124. local time settings ATTENTION There is a risk of explosion if the real time clock battery is replaced with the wrong type The CN2600 s real time clock is powered by a lithium battery We strongly recommend that you do not attempt replacement of the lithium battery without help from a qualified Moxa support engineer If you need to change the battery please contact the Moxa RMA service team Time zone default GMT Greenwich Mean Time This field shows the currently selected time zone and allows you to select a different time zone Local time This field shows the time that you last opened or refreshed the browser To set the local time for the CN2600 click on the Modify button then submit your changes in the screen as shown below 5 6 CN2600 Series User s Manual 3 Time Settings Modify time settings Date yy mm dd Time hh mm ss 2006 5 fao B fas as Submit Close Configuration with the Web Console Time server The CN2600 uses SNTP RFC 1769 for auto time calibration You may enter a time server IP address or domain name in this optional field Once the CN2600 is configured with the correct time server address it will request time information from the time server every 10 minutes Network Settings Basic Network Settings OI Main Menu CJ Overview Basic Settings ag Network Settings E CJ Basic Network Settings E CJ Advanced Network Set ag Serial Port Settings E Port 1 E H
125. locks third party cookies that do not have a compact privacy policy Blocks third party cookies that use personally identifiable information without your explicit consent i 4 Blocks first party cookies that use personally identifiable information without implicit consent Sites Import Advanced Default M Pop up Blocker Prevent most pop up windows from appearing IV Block pop ups Settings Cancel Apply ATTENTION If you are not using Internet Explorer cookies are usually enabled through a web browser setting such as allow cookies that are stored on your computer or allow per session cookies 5 2 CN2600 Series User s Manual Configuration with the Web Console Trusted Site Settings For Windows 2003 users you may need to add the CN2600 s IP address to your browser s list of trusted sites 1 If you see the following window while attempting to view the web console click on Add to modify the list of trusted sites x Content from the Web site listed below is being blocked by the Internet Explorer Enhanced ose Security Configuration http 44192 168 127 254 PEPAY H PAAANO Learn more about Internet Explorer s Enhanced Security Configuration If you trust this Web site you can lower security settings for Add the site by adding it to the Trusted sites zone If you know this Web site is on your local intranet review help for instruct
126. me and the total length of data must be less than or equal to the CN2600 s internal buffer size 1 KB per port TCP Client Mode OI Main Menu o A Operation Modes CI Overview CJ Basic Setti o asic Se ings PAWA EJ Network Settings aa E Applicatio Socket N Ely Serial Port Settings pA By port i Mode TCP Client 0 Operation Modes TCP alive check time 7 0 99 min CJ Communication p Inactivity time 0 0 65535 ms CJ Data Buffering Lo Ignore jammed IP O Enable Disable F CJ Modem Settings Destination address 1 Port 4001 HG Port2 r ry Destination address 2 Port 4001 HC Port 3 i HE Port 4 Destination address 3 Port 4001 AJ Port 5 Destination address 4 Port 4001 HE Port 6 Designated local port 1 5010 _ BG Port Designated local port 2 5011 A Ports Designated local port 3 5012 LJ Welcome Message gt i Designated local port 4 5013 AJ System Management EG System Monitoring Connection control Startup None v E Save Configuration Data Packing HC Restart Packet length O 0 1024 Delimiter 1 00 Hex C Enable Delimiter 2 00 Hex Cl Enable Delimiter process Do Nothing v Processed only when Packing length is 0 Force transmit 0 0 65535 ms i P1 Cpe ips 1 p4 Ops C P6 O P7 Cpe Apply the above settings to CJ All ports v a a TCP alive check time default 7 min This field specifies how long the CN2600 will wait for a response to keep alive packets before clo
127. message O Enable Disable BG Porti BE Port 2 BG ports 2 Part4 BO ports BO Port 6 BA Port7 SE Ports Welcome Message ae System Management a System Monitoring CJ save Configuration HE Restart Welcome Message Welcome Message Message You can enable and enter a welcome message to greet dial in or terminal users For ports configured for other modes the welcome message will not apply 7 4 8 System Management Settings In this chapter we describe additional server settings on the CN2600 The same configuration options are also available through the telnet and serial console This chapter covers the following topics E M gt gt gt gt gt gt gt isc Network Settings Accessible IP List SNMP Agent Settings DDNS Host Table User Table Authentication Server System Log Settings Q Auto Warning Settings gt gt gt gt Event Settings Serial Event Settings E mail Alert SNMP Trap LJ Maintenance gt VV Y Y gt Console Setting Ping Firmware Upgrade Configurating Import Export Load Factory Defaults Change Password LJ Certificate gt gt Ethernet SSL Certificate Import Certificate Key Delete System Monitoring Serial to Network Connections Serial Port Status Serial Port Error Count Serial Port Settings Network Connections Network Statistics Serial Data Log System Log VV V VV VV V Y Routing Save Co
128. n but it must be at least larger than one character interval within the specified baudrate For example assume that the serial port is set to 1200 bps 8 data bits 1 stop bit and no parity In this case the total number of bits needed to send a character is 10 bits and the time required to transfer one character is 10 bits 1200 bits s x 1000 ms s 8 3 ms Therefore you should set the force transmit time to be larger than 8 3 ms so in this case it must be greater than or equal to 10 ms If it is necessary to send a series of characters in the same packet the serial device will need to send that series of characters within the specified force transmit time and the total length of data must be less than or equal to the CN2600 s internal buffer size 1 KB per port 6 6 CN2600 Series User s Manual Socket Applications TCP Server Mode Configuring Serial Port Operation Modes SI Main Menu a DJ Overview CJ Basic Settings Operation Modes Port 1 HE Network Settings a JE j A at EXSY Serial Port Settings pplication Mode BG Port 1 CJ Operation Modes Ab CJ Communication P NG Data Buffering Lo bE Modem Settings TCP alive check time Inactivity time Max connection Ignore jammed IP 7 S Port 2 Allow driver control 8G Ports iti pant BJ Port 4 Bey Port 5 Cmd port BG ports Connection goes down 0G Port CJ Ports Data Packing J Welcome Message HG System Management SE S
129. n being disconnected it is highly recommended that this value is set large enough so that the intended data transfer is completed Auto Link Protocol If this field is set to None the CN2600 will not connect to the host automatically If Auto Link Protocol is set to Telnet or Rlogin the CN2600 will connect to the host automatically using the specified protocol Primary and Secondary host address If specified the fields designate permanent hosts to which the terminal will always be connected 6 22 CN2600 Series User s Manual Configuring Serial Port Operation Modes Telnet TCP port default 23 By default the Telnet TCP port number is set to 23 which is the default TCP port number for Telnet Terminal type default ansi Some older terminal applications may require that the terminal type be transmitted before the connection can be established You may need to refer to the server s documentation to determine the appropriate terminal type For most applications this setting will be unnecessary and will have no effect Quit default E 0x05 This field configures the quick key used to disconnect the link between the current terminal session and the remote host It is not necessary for binary communication Authentication type default None This field allows you to configure the method used if any to verify a user s ID and authorization Verify the ID against the CN2600 User Table RADIUS Verify the ID against the external
130. nance HE Certificate a System Monitoring ae Serial Status Hi System Status R Save Configuration Restart Restart System Go to Restart System under Restart and then click Restart to restart the CN2600 Ensure that you save all your configuration changes before you restart the system or else these changes will be lost gt Total Solution for Industrial Device Networking 4 Main Menu i Restart System 189 Overview a Basic Settings a Network Settings ao Serial Port Settings Clicking Restart will disconnect all serial and Ethernet connections and reboot the Ey System Management i s DEE SATON s Da Y g NOTE Unsaved configuration changes will be discarded and data currently in the BC Misc Network Settings middle of transmission may be lost E caim Auto Warning Settings E ae Maintenance Perag O Certificate ao System Monitoring Ef Serial Status HG System Status fa Save Configuration HS Restart i Restart System CJ Restart Ports 111 Warning 8 19 CN2600 Series User s Manual System Management Settings Restart Ports Go to Restart Ports under Restart and then select the ports to be restarted Click Select All to select all the ports Click Submit to restart the selected ports Total Solution for Industrial Device Networking 4 Main Menu E Restart Ports gm Overview a Basic Settings Restart the selected serial ports Bo Network Settings SE Serial Port Settings Select Ports
131. nance Read write password C Hi Certificate Read write privacy l ae mode a System Monitoring v Read write privacy CJ Save Configuration CJ Restart z Submit lt SNMP To enable the SNMP Agent function select the Enable option and enter a community name e g public Read community string default public This is a text password mechanism that is used to weakly authenticate queries to agents of managed network devices Write community string default private This is a text password mechanism that is used to weakly authenticate changes to agents of managed network devices Contact name The optional SNMP contact information usually includes an emergency contact name and telephone or pager number Location Use this optional field to specify the location string for SNMP agents such as the CN2600 This string is usually set to the street address where the CN2600 1s physically located SNMP agent version The CN2600 supports SNMP V1 V2 and V3 8 3 CN2600 Series User s Manual System Management Settings Read only and Read write access control DDNS The following fields allow you to define user names passwords and authentication parameters for two levels of access read only and read write The name of the field will indicate which level of access it refers to For example Read only authentication mode allows you to configure the authentication mode for read only access whereas Read write authentication mo
132. ne character is 10 bits 1200 bits s x 1000 ms s 8 3 ms Therefore you should set the force transmit time to be larger than 8 3 ms so in this case it must be greater than or equal to 10 ms If it is necessary to send a series of characters in the same packet the serial device will need to send that series of characters within the specified force transmit time and the total length of data must be less than or equal to the CN2600 s internal buffer size 1 KB per port UDP Mode Main Menu Operation Modes A CJ Overview R Basic Settings Port1 H Network Settings Application Socket v ER Serial Port Settings Mode UDP E PI ores Destination address 1 Begin End Port 4001 5 G3 Operation Modes EE WA Destination address 2 Begin End Port 4001 LI Communication P gt x Data Buffering Lo Destination address 3 Begin End Port 4001 a odem Settings Destination address 4 Begin End Port 4001 BC Port2 Local listen port 4001 EL Port 3 Data Packing PB NEE Packet length o 0 1024 Go acket len 2 BO ports x HE part 6 Delimiter 1 00 Hex Enable AJ Port Delimiter 2 00 Hex Cl Enable ay Port 8 Delimiter process Do Nothing Processed only when Packing length is 0 CJ Welcome Message Force transmit o 0 65535 ms HQ System Management a ae a P1 F P2 p3 F P4 Ops CO P6 C P7 Cpe H System Monitoring Apply the above settings to ie S l CIAll ports CJ Save Configuration p
133. nes how the port will proceed if multiple hosts are connected and one or more of the hosts stops responding as the port is transmitting data If you select No the port will wait until the data has been transmitted successfully to all hosts before transmitting the next group of data If you select Yes the port will ignore the host that stopped responding and continue data transmission to the other hosts Destination address 1 through 4 default None Specifying an IP address allows the CN2600 to connect actively to the remote host At least one destination must be provided TCP port default 4001 This is the TCP port number assignment for the serial port on the CN2600 It is the port number that the serial port uses to listen to connections and that other devices must use to contact the serial port To avoid conflicts with well known TCP ports the default is set to 4001 A ATTENTION Up to 4 connections can be established between the CN2600 and hosts The connection speed or throughput may be low if any one of the four connections is slow since the one slow connection will slow down the other 3 connections A ATTENTION The Destination IP address parameter can be the IP address domain name or the name defined in the host table For some applications the user may need to send the data actively to the remote destination domain name Designated local port 1 through 4 default 5010 through 5013 Use these fields to specify the designat
134. nfiguration Restart gt Restart System gt Restart Ports CN2600 Series User s Manual System Management Settings Misc Network Settings Accessible IP List Accessible IP List TF Enable the accessible IP list Disable will allow all IP s connection request 4 Port 13 No Active IP Address Netmask CJ Port 14 4 Port 15 CJ Port 16 CJ Welcome Message L Ka ES System Management EHI Misc Network Settings CJ Accessible IP List 9 SNMP Agent DONS CJ Host Table CJ Route Table CJ User Table CJ Authentication Server CJ System Log Settings a Auto Warning Settings SH Maintenance YC Certificate AJ System Monitoring CJ Save Configuration 4 Restart oon vd wo AUN UL CL D U Mo Wa O Mv Bo Gn Ka Bo Ma Da The CN2600 uses an IP address based filtering method to control access to its serial ports The Accessible IP list allows you restrict network access to the CN2600 Access is controlled by IP address When the accessible IP list is enabled a host s IP address must be listed in order to have access to the CN2600 You may add a specific address or range of addresses by using a combination of IP address and netmask as follows To allow access to a specific IP address Enter the IP address in the corresponding field enter 255 255 255 255 for the netmask To allow access to hosts on a specific subnet For both the IP address and netmask use 0 for the last digit e g 192 168 1 0 and 255 255 255 0 To all
135. ngs i System C System Cold Start System Warm Start Power Down 4 Serial Port Settings a Man n sa a a S hea eis Network D DHCP BOOTP PPPoE Gat IP Renew NTP Mail Fail NTP Connect Fail IP Conflict Network Link Down IT Misc Network Settings Gy Accessible IP List Config o Login Fail IP Changed Password Changed Config Changed Firmware Upgrade SSL Certificate Import Config Import Config Export CJ SNMP Agent CJ DONS OpMode g Connect Disconnect Authentication Fail Restart TJ Host Table I Route Table User Tabie CJ Authentication Serve System Log Settings 4 Auto Warning Settings Maintenance PJ Certficate TM system Monitoring CJ Save Configuration 1 Restart System Log Settings allows the administrator to customize which network events are logged by the CN2600 Events are grouped into four categories known as event groups and the administrator selects which groups to log under Local Log The actual system events that would be logged for each system group are listed under summary For example if System was enabled then System Cold Start events and Power Down events for 2AC model would be logged CN2600 Series User s Manual System Management Settings System Cold Start System Warm Start Power Down I DHCP BOOTP PPPoE Get IP Renew NTP Mail Fail NTP Connect Fail DHCP Fail IP Conflict Ethernet Link Down Confi Login Fail IP Changed Password Changed Config Changed Firmware 8 Upgrade SSL Key Import
136. ntrol when data should be sent ATTENTION In order to enable a delimiter packet length must be set to 0 Delimiter 2 should only be enabled in conjunction with Delimiter 1 and never on its own otherwise there may be data errors Even when a delimiter is enabled the CN2600 will still pack and send the data when the amount of data exceeds 1 KB Delimiter process default Do Nothing The Delimiter process field determines how the data is handled when a delimiter is received Delimiter 1 must be enabled for this field to have effect If Delimiters 1 and 2 are both enabled both characters must be received for the delimiter process to take place e Do Nothing Data in the buffer will be transmitted when the delimiter is received e Delimiter 1 Data in the buffer will be transmitted after 1 additional byte is received following the delimiter e Delimiter 2 Data in the buffer will be transmitted after 2 additional bytes are received following the delimiter e Strip Delimiter Data in the buffer is first stripped of the delimiter before being transmitted Force transmit default 0 ms This parameter defines how large a gap in serial communication the CN2600 will allow before packing the serial data in its internal buffer for network transmission As data is received through the serial port 1t is stored by the CN2600 in the internal buffer The CN2600 transmits data stored in the buffer via TCP IP but only when the internal buffer is
137. nvironment For correct gateway IP address information consult the network administrator ATTENTION In dynamic IP environments the firmware will try to get the network settings from the DHCP or BOOTP server 3 times every 30 seconds until network settings are assigned by the DHCP or BOOTP server The first try times out after 1 second the second after 3 seconds and the third after 5 seconds If the DHCP BOOTP server is unavailable the firmware will use the default IP address 192 168 127 254 netmask and gateway settings DNS server 1 This is an optional field If your network has access to a DNS server you may enter the DNS server s IP address in this field This allows the CN2600 to use domain names instead of IP addresses to access hosts Domain Name System DNS is the way that Internet domain names are identified and translated into IP addresses A domain name is an alphanumeric name such as www moxa com that it is usually easier to remember than the numeric IP address A DNS server is a host that translates this kind of text based domain name into the actual IP address used to establish a TCP IP connection When the user wants to visit a particular website the user s computer sends the domain name e g www moxa com to a DNS server to request that website s numeric IP address When the IP address is received from the DNS server the user s computer uses that information to connect to the website s web server 5 8
138. o This option determines how the port will proceed if driver control commands are received from multiple hosts that are connected to the port If No is selected driver control commands will be ignored If Yes is selected control commands will be accepted with the most recent command received taking precedence 6 14 CN2600 Series User s Manual Configuring Serial Port Operation Modes A Connection goes down default always high You can configure what happens to the RTS and DTR signals when the Ethernet connection goes down For some applications serial devices need to know the Ethernet link status through RTS or DTR signals sent through the serial port Use goes low if you want the RTS and DTR signal to change their state to low when the Ethernet connection goes down Use always high if you do not want the Ethernet connection status to affect the RTS or DTR signals Packet length default 0 The Packet length setting refers to the maximum amount of data that 1s allowed to accumulate in the serial port buffer before sending At the default of 0 for packet length no maximum amount is specified and data in the buffer will be sent as specified by the delimiter settings or when the buffer is full When a packet length between 1 and 1024 bytes is specified data in the buffer will be sent as soon it reaches the specified length Delimiter 1 and Delimiter 2 default None When Delimiter 1 is enabled the serial port will clear the buffer and
139. older generation equipment or as a backup configuration method when the network is down CN2600 reverse terminal modes allow the use of the CN2600 User Table or a RADIUS server for identity verification purposes Please refer to the Misc Network Settings section in Chapter 8 System Management Settings for instructions on setting up the CN2600 User Table Reverse Telnet Reverse Telnet mode is widely used for device management in telecommunication control rooms The system waits for a host on the network to initiate a connection Since TCP Server mode does not assist with conversion of CR LF commands reverse terminal applications that require this conversion should use Reverse Telnet mode 4 9 CN2600 Series User s Manual Serial Port Operation Modes Dial In Out Modes Web Server E mail Server i p TCP IP 55555555 DUE Series 7 Router Modem PPP SLIP PPP Dialout Dialin Dialin Internet Notebook The CN2600 provides dial in dial out access for ISPs and enterprises that need a remote access solution When a user at a remote site uses a PPP dial up connection to access the CN2600 the CN2600 plays the role of a dial up server but also ensures that the user has legal access to the network by verifying the user s identity with the CN2600 User Table or a RADIUS server Please refer to the Misc Network Settings section in Chapter 8 System Management Settings for instructions on setting up the CN2600 User T
140. ommunication the CN2600 will allow before packing the serial data in its internal buffer for network transmission As data is received through the serial port it is stored by the CN2600 in the internal buffer The CN2600 transmits data stored in the buffer via TCP IP but only when the internal buffer is full or 6 8 CN2600 Series User s Manual Configuring Serial Port Operation Modes as specified by the force transmit time When set to O the force transmit time is disabled and transmission is determined solely by the data in the internal buffer At 1 to 65535 the TCP IP protocol software will pack the serial data received after there is a gap in serial communication that exceeds the specified force transmit time The optimal force transmit time depends on your application but it must be at least larger than one character interval within the specified baudrate For example assume that the serial port is set to 1200 bps 8 data bits 1 stop bit and no parity In this case the total number of bits needed to send a character is 10 bits and the time required to transfer one character is 10 bits 1200 bits s x 1000 ms s 8 3 ms Therefore you should set the force transmit time to be larger than 8 3 ms so in this case it must be greater than or equal to 10 ms If it is necessary to send a series of characters in the same packet the serial device will need to send that series of characters within the specified force transmit ti
141. on Redundant COM does not support security function 9 16 CN2600 Series User s Manual Software Installation Configuration 12 To save the configuration to a text file select Export from the COM Mapping menu You will then be able to import this configuration file to another host and use the same COM Mapping settings in the other host 4 NPort Windows Driver Manager 15 x File COM Mapping view Help F gih add Ctrl M eg rl E5 Ex HIE Remove Ctrl D Apply Undo Setting Sie SI Setting CC aaa E PE rts 192 168 127 254 951 967 Pot2 192 168 126 254 951 967 3 m 192 166 127 254 952968 Porta 192 169 126 254 952 962 4 Undo CHIZ 192 169 127 254 953 969 Portd 192 169 126 254 953 969 F Peon m 192 168 127 254 954 970 Por5 192 169 126 254 954 970 S dpi 192 168 127 254 55 971 PonB 192 168 126 254 955 971 7 Import 192 168 127 254 956 972 Port7 192 168 126 254 956 972 o TETO 192 168 127 254 957 973 Pot8 192 169 126 254 957 973 Total COM Fort 8 at Windows Monitor Utility Installing the NPort Monitor Utility The NPort Monitor Utility is used to monitor the status of redundant COM mode connections The utility is designed for use with Windows 95 98 ME NT 2000 XP 2003 V ista 1 Click the INSTALL Monitor Utility button in the CN2600 Installation CD auto run window to install the NPort Monitor Utility Once the installation program starts running click Yes to proceed 9 17 CN2600 Se
142. one When Delimiter 1 is enabled the serial port will clear the buffer and send the data to the Ethernet port when a specific character entered in hex format is received A second delimiter character may be enabled and specified in the Delimiter 2 field so that both characters act as the delimiter to indicate when data should be sent ATTENTION In order to enable a delimiter packet length must be set to 0 Delimiter 2 should only be enabled in conjunction with Delimiter 1 and never on its own otherwise there may be data errors Even when a delimiter is enabled the CN2600 will still pack and send the data when the amount of data exceeds 1 KB Delimiter process default Do Nothing The Delimiter process field determines how the data is handled when a delimiter is received Delimiter 1 must be enabled for this field to have effect If Delimiters 1 and 2 are both enabled both characters must be received for the delimiter process to take place e Do Nothing Data in the buffer will be transmitted when the delimiter is received e Delimiter 1 Data in the buffer will be transmitted after 1 additional byte is received following the delimiter e Delimiter 2 Data in the buffer will be transmitted after 2 additional bytes are received following the delimiter e Strip Delimiter Data in the buffer is first stripped of the delimiter before being transmitted Force transmit default 0 ms This parameter defines how large a gap in serial c
143. onnection status to affect the RTS or DTR signals Packet length default 0 The Packet length setting refers to the maximum amount of data that is allowed to accumulate in the serial port buffer before sending At the default of 0 for packet length no maximum amount is specified and data in the buffer will be sent as specified by the delimiter 6 16 CN2600 Series User s Manual Configuring Serial Port Operation Modes A settings or when the buffer is full When a packet length between 1 and 1024 bytes is specified data in the buffer will be sent as soon it reaches the specified length Delimiter 1 and Delimiter 2 default None When Delimiter 1 is enabled the serial port will clear the buffer and send the data to the Ethernet port when a specific character entered in hex format is received A second delimiter character may be enabled and specified in the Delimiter 2 field so that both characters act as the delimiter to control when data should be sent ATTENTION In order to enable a delimiter packet length must be set to 0 Delimiter 2 should only be enabled in conjunction with Delimiter 1 and never on its own otherwise there may be data errors Even when a delimiter is enabled the CN2600 will still pack and send the data when the amount of data exceeds KB Delimiter process default Do Nothing The Delimiter process field determines how the data is handled when a delimiter is received Delimiter 1 must be enabled for this
144. ons before continuing Click Next to continue or Cancel to exit Setup Ka CN2600 Series User s Manual Software Installation Configuration 3 Click Next to install program files to the default directory or click Browse to select an alternate location Select Destination Location Where should NPort Windows Driver Manager be installed 4 Click Next to install the program s shortcuts in the appropriate Start Menu folder Select Start Menu Folder Where should Setup place the program s shortcuts CN2600 Series User s Manual Software Installation Configuration 5 Click Next to proceed with the installation The installer then displays a summary of the installation options na Setup NPort Windows Driver Manager Ready to Install Setup is now ready to begin installing NPort Windows Driver Manager on your computer Click Install to continue with the installation or click Back if you want to review or change any settings Destination location C Program Files N Part Dn Manager Start Menu folder NPort Windows Driver Manager Be cack ma Cro 6 Click Install to begin the installation The setup window will report the progress of the installation To change the installation settings click Back and navigate to the previous screen In Windows XP a message will appear indicating that the software has not passed Windows Logo testing Click Continue Anyway to finish the installation i
145. ow unrestricted access Deselect the Enable the accessible IP list option Refer to the following table for more configuration examples 192 168 0 1 to 192 168 255 254 192 168 0 0 255 255 0 0 192 168 1 1 to 192 168 1 126 192 168 1 0 255 255 255 128 192 168 1 129 to 192 168 1 254 192 168 1 128 255 255 255 128 8 2 CN2600 Series User s Manual System Management Settings ATTENTION The Accessible IP List will not be used if you configure the serial port for DRDAS Real COM mode or DRDAS TCP Server mode In this case the Primary IP address three Backup IP addresses and filtering method from the DRDAS configuration will be used SNMP Agent Settings Total Solution for Industrial Device Networking AJ Port 9 aj 3 SNMP Agent Settings AE Port 10 KS te pota Configuration Port 12 SNMP Enable Disable aE Port 13 ba HE Port 14 Read community string public BJ Port 15 pawan community agay PE Port 16 Contact name FS c KC c 9 CJ Welcome Message Location oO AI System Management l SS Misc Network Settings SNMP agent version Mvi NM v2 F v3 CJ Accessible IP List Read only user name CJ SNMP Agent Read only E S authentication mode DONS Read only password CJ Host Table SE Read only privacy CJ Route Table mode CJ User Table Read only privacy CJ Authentication Server Read write user name J System Log Settings Read write HG Auto Warning Settings authentication mode 9 Mainte
146. r usr etc cd usr etc 3 Extract the source files from the tar file by executing the command tar xvf moxattyd tar The following files will be extracted README TXT moxattyd c source code moxattyd cf an empty configuration file Makefile makefile VERSION TXT fixed tty driver version FAQ TXT 4 Compile and Link For SCO UNIX make sco For UnixWare 7 make svr5 For Unix Ware 2 1 x SVR4 2 make svr42 9 24 CN2600 Series User s Manual Software Installation Configuration Configuring the UNIX Driver Modify the configuration The configuration used by the moxattyd program is defined in the text file moxattyd cf which is in the same directory that contains the program moxattyd You may use vi or any text editor to modify the file as follows ttyp1 192 168 1 1 950 For more configuration information view the file moxattyd cf which contains detailed descriptions of the various configuration parameters NOTE The Device Name depends on the OS See the Device Naming Rule section in README TXT for more information To start the moxattyd daemon after system bootup add an entry into etc inittab with the tty name you configured in moxattyd cf as in the following example ts 2 respawn usr etc moxattyd moxattyd t 1 Device naming rule For UnixWare 7 UnixWare 2 1 x and SVR4 2 use pts n1 For all other UNIX operating systems use ttyp 7 Starting moxattyd Execute the
147. r process field determines how the data is handled when a delimiter is received Delimiter 1 must be enabled for this field to have effect If Delimiters 1 and 2 are both enabled both characters must be received for the delimiter process to take place e Do Nothing Data in the buffer will be transmitted when the delimiter is received e Delimiter 1 Data in the buffer will be transmitted after 1 additional byte is received following the delimiter e Delimiter 2 Data in the buffer will be transmitted after 2 additional bytes are received following the delimiter e Strip Delimiter Data in the buffer is first stripped of the delimiter before being transmitted Force transmit default 0 ms This parameter defines how large a gap in serial communication the CN2600 will allow before packing the serial data in its internal buffer for network transmission As data is received through the serial port it is stored by the CN2600 in the internal buffer The CN2600 transmits data stored in the buffer via TCP IP but only when the internal buffer is full or as specified by the force transmit time When set to 0 the force transmit time is disabled and transmission is determined solely by the data in the internal buffer At 1 to 65535 the TCP IP protocol software will pack the serial data received after there is a gap in serial communication that exceeds the specified force transmit time The optimal force transmit time depends on your applicatio
148. rd and Confirm password boxes blank 8 13 CN2600 Series User s Manual System Management Settings ATTENTION If you forget the password the ONLY way to configure the CN2600 is by using the reset button on the CN2600 s casing to load the factory defaults Before you set a password for the first time it 1s a good idea to export the configuration to a file when you have finished setting up your CN2600 Your configuration can then be easily imported back into the CN2600 if you need to reset the CN2600 due to a forgotten password or for other reasons Please refer to the section on Configuration Import Export earlier in this chapter for more details Certificate Ethernet SSL Certificate Import ap Total Solution for Industrial Device Networkin J Main Menu i Overview f Basic Settings a Network Settings Ethernet SSL Certificate Import Installed Certificate l E Issued to 192 168 127 754 TTG Serial Port Settings Issued by 192 158 127 254 o System Management Valid from 20274473 to 20377442 E ag Misc Network Settings a Auto Warning Settings ae Select SSL Wo AL Maintenance certificate key file _ Browse oo Certificate C2 Ethernet SSL Certifica Ccupme CJ Certificate key Delete SIS System Monitoring E Save Configuration BME Restart Certificate Key Delete mp Total Solution for Industrial Device Networkin cal Main Menu CJ Overview E Basic Settings Y Network Settings Gal
149. receive a driver response of success when the software uses any of the Win32 API functions The firmware will only send data back to the driver on the host Data will be sent first in first out when data comes into the CN2600 from the Ethernet interface ATTENTION When Max connection is greater than 1 the CN2600 will use a multi connection application 1 e 2 to 8 hosts are allowed access to the port at the same time When using a multi connection application the CN2600 will use the serial communication parameters as defined here in the web console and all hosts connected to the port must use identical serial settings If one of the hosts opens the COM port with different serial settings data will not be transmitted properly Ignore jammed IP default No This option determines how the port will proceed if multiple hosts are connected and one or more of the hosts stops responding as the port is transmitting data If you select No the port will wait until the data has been transmitted successfully to all hosts before transmitting the next group of data If you select Yes the port will ignore the host that stopped responding and continue data transmission to the other hosts Allow driver control default No This option determines how the port will proceed if driver control commands are received from multiple hosts that are connected to the port If No is selected driver control commands will be ignored If Yes is selected control
150. rein to correct such errors and these changes are incorporated into new editions of the publication Technical Support Contact Information www moxa com support Moxa Americas Moxa China Shanghai office Toll free 1 888 669 2872 Toll free 800 820 5036 Tel 1 714 528 6777 Tel 86 21 5258 9955 Fax 1 714 528 6778 Fax 86 21 5258 5505 Moxa Europe Moxa Asia Pacific Tel 49 89 3 70 03 99 0 Tel 886 2 8919 1230 Fax 49 89 3 70 03 99 99 Fax 886 2 8919 1231 Chapter 1 Chapter 2 Chapter 3 Chapter 4 Table of Contents INIKOQUCHON aaa EAEE 1 1 Product TTT 1 2 IS a AA NANANA ANNA NAA AA 1 2 NA AA es 1 2 Package CNEEkI TTT 1 2 AA ane T 1 3 Rear Panglaaaan ania NAAN AA AA ANA AA 1 4 Se 10 AA On eae 1 5 Hardware INSTA ATION 23ANG AA 2 1 IDESKUOD kagaanan LAKAD O Nak A E GG AASA NAIA BALAI ROON MANANANGGAL a 2 2 a Nero tye eee ome ES ter EA ere cee R Tee E ce 2 2 WALKING Re QUIECINCIS TTT 2 2 Connecting the CN2600 8 16 s Power sss esse 2 3 Conmecuns tohe NC UWOEK TT 2 3 Connecune toa Serial DON AN aa naaa 2 3 Connecting to the Console Port 71177777770 2 3 Adjustable Pull High Low Resistors for the RS 485 Port 1 1 01111 2 4 Initial IP Address ConfiQuration ccccccessseeeccesseeeceessseeeeenseesseneeeees 3 1 Static and Dynamic IFAdUES Se Se 3 2 Factory Derah IP AddTOSS airn E AANO 3 2 Connon AA 3 2 Terminal Server searc KUO anen A NAA NIRA NAA 3 2 WED CONL01 GA maana aa ee a ore 3 2 L
151. rial port buffer before sending At the default of O for packet length no maximum amount is specified and data in the buffer will be sent as specified by the delimiter settings or when the buffer is full When a packet length between 1 and 1024 bytes is specified data in the buffer will be sent as soon it reaches the specified length Delimiter 1 and Delimiter 2 default None When Delimiter 1 is enabled the serial port will clear the buffer and send the data to the Ethernet port when a specific character entered in hex format is received A second delimiter character may be enabled and specified in the Delimiter 2 field so that both characters act as the delimiter to indicate when data should be sent ATTENTION In order to enable a delimiter packet length must be set to 0 Delimiter 2 should only be enabled in conjunction with Delimiter 1 and never on its own otherwise there may be data errors Even when a delimiter is enabled the CN2600 will still pack and send the data when the amount of data exceeds 1 KB Delimiter process default Do Nothing The Delimiter process field determines how the data is handled when a delimiter is received Delimiter 1 must be enabled for this field to have effect If Delimiters 1 and 2 are both enabled both characters must be received for the delimiter process to take place e Do Nothing Data in the buffer will be transmitted when the delimiter is received e Delimiter 1 Data in the buffer will
152. ries User s Manual Software Installation Configuration 2 Click Next when the Welcome screen opens to proceed with the installation Setup NPort Monitor Utility alsia Welcome to the NPort Monitor Utility Setup Wizard This will install NPort Monitor Utility er 1 0 on your computer kis recommended that you close all other applications before continuing Click Next to continue or Cancel to exit Setup 3 Click Next to install program files to the default directory or click Browse to select an alternate location iG Setup NPort Monitor Utility Select Destination Location Where should MPort Monitor Utility be installed CJ Setup will install N Fort Monitor Utility into the following Folder To continue click Hest IF you would like to select a different folder click Browse E Fra qra i Files MA Portbdonitor Atleast 1 1 ME of free disk space is required 9 18 CN2600 Series User s Manual Software Installation Configuration 4 Click Next to proceed with the installation The installer then displays a summary of the installation options o Setup NPort Monitor Utility Select Additional Tasks Which additional tasks should be performed Select the additional tasks you would like Setup to perform while installing N Hort Monitor Utility then click Next Additional icons 5 Click Install to begin the installation The setup window will report the progress of t
153. rk transmission As data is received through the serial port it is stored by the CN2600 in the internal buffer The CN2600 transmits data stored in the buffer via TCP IP but only when the internal buffer is full or as specified by the force transmit time When set to O the force transmit time is disabled and transmission is determined solely by the data in the internal buffer At 1 to 65535 the TCP IP protocol software will pack the serial data received after there is a gap in serial communication that exceeds the specified force transmit time The optimal force transmit time depends on your application but it must be at least larger than one character interval within the specified baudrate For example assume that the serial port is set to 1200 bps 8 data bits 1 stop bit and no parity In this case the total number of bits needed to send a character is 10 bits and the time required to transfer one character is 10 bits 1200 bits s x 1000 ms s 8 3 ms Therefore you should set the force transmit time to be larger than 8 3 ms so in this case it must be greater than or equal to 10 ms If it is necessary to send a series of characters in the same packet the serial device will need to send that series of characters within the specified force transmit time and the total length of data must be less than or equal to the CN2600 s internal buffer size 1 KB per port 6 13 CN2600 Series User s Manual Configuring Serial Port
154. rnal buffer for network transmission 6 15 CN2600 Series User s Manual Configuring Serial Port Operation Modes DRDAS DRDAS Real COM J Main Menu Application DRDAS v S Overview Mode DRDAS Real COM CI Basic Settings H Network Settings EI Serial Port Settings TCP alive check time 7 0 99 min Ignore jammed IP O Enable Disable Primary IP address EXSY Port1 Cj Operation Modes Backup 1 IP address 3 CJ Communication P Backup 2 IP address l i CJ Data Buffering Lo Backup 3 IP address Se Soden Settings Connection goes down RTS Oalways low always high S Port 2 DTR always low O always high IG Port 3 3 ae a Data Packing BI Port Hy Port 5 Packet length o 0 1024 HG ports Delimiter 1 00 Hex Cl Enable BG Port Delimiter 2 00 Hex Enable ao nee Delimiter process Do Nothing Processed only when Packing length is 0 CJ Welcome Message Force transmit 0 0 65535 ms YH System Management em P1 P2 ips CIP4 OPs C P6 Cp ips HI System Monitoring Apply the above settings to CJ Save Configuration CAII ports HS Restart M 3 TCP alive check time default 7 min This field specifies how long the CN2600 will wait for a response to keep alive packets before closing the TCP connection The CN2600 checks connection status by sending periodic keep alive packets If the remote host does not respond to the packet within the time specified in this field the CN2600 wi
155. rol modes the CN2600 will listen for another TCP connection from another host after closing the connection If TCP alive check time is set to 0 the TCP connection will remain open even 1f there is no response to the keep alive packets 6 23 CN2600 Series User s Manual Configuring Serial Port Operation Modes Inactivity time default 0 min This field specifies the idle time setting for auto disconnection A setting of O min will cause the port to remain connected even if idle TCP port default 4001 This is the TCP port number assignment for the serial port on the CN2600 It is the port number that the serial port uses to listen to connections and that other devices must use to contact the serial port To avoid conflicts with well known TCP ports the default is set to 4001 Authentication type default None This field allows you to configure the method used if any to verify a user s ID and authorization Verify the ID against the CN2600 User Table RADIUS Verify the ID against the external RADIUS server Authentication is not required Map keys lt CR LF gt default CR LF This specifies how the ENTER key is mapped from the Ethernet port through the serial port lt CR LF gt carriage return line feed 1 e the cursor will jump to the next line and return to the first character of the line carriage return i e the cursor will return to the first character of lt CR gt the line line feed 1 e the c
156. rt Web Console Navigation In the CN2600 web console the left panel is the navigation panel and contains an expandable menu tree for navigating among the various settings and categories When you click on a menu item in the navigation panel the main window will display the corresponding options for that item Configuration changes can then be made in the main window For example if you click on Basic Settings in the navigation panel the main window will show a page of basic settings that you can configure You must click on the Submit button to keep your configuration changes The Submit button will be located at the bottom of every page that has configurable settings If you navigate to another page without clicking the Submit button your settings will not be retained Changes will not take effect until they are saved and the NPort is restarted You may complete this in one step by clicking on the Save Restart option after you submit a change If you need to make several changes before restarting you may save your changes without restarting by selecting Save Configuration in the navigation panel If you restart the CN2600 without saving your configuration the CN2600 will discard all submitted changes 5 5 CN2600 Series User s Manual Configuration with the Web Console Basic Settings You may access Basic Settings in the navigation panel Server Settings EJ Main Menu CO Overview Basic Settings A Basic settinas SarierSep
157. rt 1 Mode RFC2217 lt i E Operation Modes TCP alive check time 7 0 99 min 35 C9 Communication P TCP port 4001 Data Buffering Lo Data Packing E E Modem Settings ENS a lt Packet length 0 KO 1024 BO Port2 ae BE Porta Delimiter 1 00 Hex Cl Enable Port 4 Delimiter 2 00 Hex C Enable RG Port5 Delimiter process Do Nothing Processed only when Packing length is 0 i a Port 6 Force transmit 0 ko 65535 ms i pa dna BAKING pt Bee Ores Hr Bes Ore Mp ps HQ Ports Apply the above settings to Call ports 2 Welcome Message HA System Management H System Monitoring l CI Save Configuration H Restart lt gt TCP alive check time default 7 min This field specifies how long the CN2600 will wait for a response to keep alive packets before closing the TCP connection The CN2600 checks connection status by sending periodic keep alive packets If the remote host does not respond to the packet within the time specified in this field the CN2600 will force the existing TCP connection to close For socket and device control modes the CN2600 will listen for another TCP connection from another host after closing the connection If TCP alive check time is set to 0 the TCP connection will remain open even if there is no response to the keep alive packets TCP port default 4001 This is the TCP port number assignment for the serial port on the CN2600 It is the port number that the serial
158. rver o Routing and Remote Access BI a te ee ee a4 Me AN Routing and Remote Access Server Setup Wizard Action Address Range Assignment Tou can specity the address ranges that this server will use to assign addresses to remote clients the Type a starting IP address and either an ending IP address or the number of Ad addresses in the range F Start IF address l i 55 End IP address Number of addresses Back Hents Cancel start a aie TS Routing and Remote B 05 PM 7 Select Yes I want to use a RADIUS server and click Next a Routing and Remote Access Miel In M2 al o em a BA Routing and Remote Access Server Setup Wizard Managing Multiple Remote Access Servers You can manage all of Your remote access servers centrally A Remote Authentication Dial ln User Service RADIUS server provides a central authentication database for multiple remote access servers and collects accounting Information about remote connections Do you want to set up this remote access server to use an existing RADIUS server No l don t want to set up this server to use RADIUS now Yes want to use a RADIUS server Windows provides a RADIUS solution called Internet Authentication Service 145 as an optional component that you can install through Add Remove Programs lt Back Cancel start 8 TS Routing and Remote A Ee 2 12 PM E 8 CN2600 Series User s Manual RADIUS Serv
159. s and dual MAC addresses DRDAS uses a backup PC that is set up to take over when the primary PC fails The CN2600 s dual host redundant configuration sends serial data to 4 IP addresses on the network Users select a Primary IP and 3 Secondary IPs When the Primary IP fails the backup IPs take over by using the switching library refer to Chapter 12 for more details With this kind of redundant setup if one of the secondary IPs tries to send commands to the serial device the commands are discarded by the CN2600 since only the Primary IP is allowed to conduct bi directional transmission The backup IPs are only allowed to receive data from the CN2600 4 6 CN2600 Series User s Manual Serial Port Operation Modes NOTE Primary PC Backup PC Primary Backup Remote Terminal Unit RTU This type of highly redundant setup 1s implemented with two CN2600 terminal servers as shown above in the structure diagram All aspects of the system are backed up including the PC hosts the networks and the CN2600 terminal servers The entire system will continue operating in the following situations 1 When the Primary PC and LAN A fail at the same time the backup PC and LAN B will take over 2 When the Primary PC and the Primary CN2600 fail at the same time the backup PC and the backup CN2600 will take over 3 When LAN A and the Primary CN2600 fail at the same time LAN B and the backup CN2600 will take over The RS 2
160. selected serial ports Note that ports that are in use will be labeled accordingly 9 13 CN2600 Series User s Manual Software Installation Configuration STOP Port Number 2 Port s are Selected Basic Settings Advanced Settings Serial Parameters Security W Auto Enumerating COM Number for Selected Parts COM Number COM3 current in usel CAPSE lF7 f2 Enable Redundant COM C happnaolP addiessi 19216834111 C happnolP addiessa 172160117 8 Enable Redundant COM which enables the 2 LANs automatically is the default If Disable Redundant COM is selected Real COM mode will be used and either LAN can be selected for mapping the IP address NOTE Before configuring the driver for Redundant COM mode you must first configure the corresponding port of the CN2600 s firmware for Redundant COM mode 9 Click the Advanced Settings tab to modify Tx Mode FIFO and Flash Flush ioj Port Number 1 Port s are Selected Basic Settings Advanced Settings Serial Parameters Security FP ppl Selected Poke The FIFO settings will overwrite the Firmware setting Ts Mode HiPerfomance FIFO Enae Network Timeout 5000 me 500 20000 IZ Auto Network Re Connection T Return error if network is unavailable Jw Fast Flush Only flush local buffer Tx Mode Hi Performance is the default for Tx mode After the driver sends data to the CN2600 the driver immediately issues a Tx Emp
161. ser Table a 1 lami o IST Bu hnn 11H Sore n 1 bml tt CI System Log Setting 10 1 bml Auto Warg Sottimgs ct i ani 7 RA Maintenance 12 1 anli Ble Ch AI System Monitoring d 3 lani 7 D Save Conbgurihon 14 1 lanl i Restart 15 1 land 5 14 6 Configuring Serial Port Operation Modes In this chapter we explain how to configure the individual serial port modes This chapter covers the following topics LI Port Setting Basics LI Device Control Applications gt Real COM Mode gt RFC2217 Mode LI Socket Applications gt TCP Server Mode gt TCP Client Mode gt UDP Mode LJ Redundant COM LY DRDAS gt DRDAS Real COM gt DRDAS TCP Server LJ Terminal Applications gt Terminal ASCII TERM_ASC gt Terminal BIN TERM_BIN Q Reverse Terminal Q Dial In Out Applications PPP Mode PPPD Mode SLIP Mode SLIPD Mode Dynamic Mode LI Disabled Mode VV VV Y CN2600 Series User s Manual Configuring Serial Port Operation Modes Port Setting Basics Fach serial port on the CN2600 can be configured independently To configure the operation mode and settings for a port expand Serial Port Settings in the navigation panel then expand the port that you would like to configure Individual port settings are grouped into four categories in the navigation panel Operation Modes Communication Parameters Data Buffering Log and Modem Settings DI Main Menu 3 d Ai 4 Operation Modes LI Overview h Basic Settin R Basic Sath
162. signed IP address 1f the DHCP server does not respond IP Address LAN1 default 192 168 127 254 LAN2 default 192 168 126 254 Enter the IP address that will be assigned to your CN2600 All ports on the CN2600 will share this IP address An IP address is a number assigned to a network device such as a computer as a permanent address on the network Computers use the IP address to identify and talk to each other over the network Choose a proper IP address that is unique and valid in your network environment Netmask default 255 255 255 0 Enter the subnet mask A subnet mask represents all of the network hosts at one geographic location in one building or on the same local area network When a packet is sent out over the network the CN2600 will use the subnet mask to check whether the desired TCP IP host specified in the packet is on the local network segment If the address is on the same network segment as the CN2600 a connection is established directly from the CN2600 Otherwise the connection is established through the given default gateway Gateway Enter the IP address of the gateway if applicable A gateway is a network computer that acts as an entrance to another network Usually the computers that control traffic within the network or at the local Internet service provider are gateway nodes The CN2600 needs to know the IP address of the default gateway computer in order to communicate with the hosts outside the local network e
163. sing the TCP connection The CN2600 checks connection status by sending periodic keep alive packets If the remote host does not respond to the packet within the time specified in this field the CN2600 will force the existing TCP connection to close For socket and device control modes the CN2600 will listen for another TCP connection from another host after closing the connection If TCP alive check time is set to 0 the TCP connection will remain open even 1f there is no response to the keep alive packets Inactivity time default 0 ms This field specifies how long the CN2600 will wait for incoming and outgoing data through the serial port before closing the TCP connection The TCP connection 6 9 CN2600 Series User s Manual Configuring Serial Port Operation Modes is closed if there is no incoming or outgoing data through the serial port for the specified Inactivity time If this field is set to 0 the TCP connection is kept active until a connection close request is received A ATTENTION Inactivity time should at least be set larger than that of Force transmit time To prevent the unintended loss of data due to the session being disconnected it is highly recommended that this value is set large enough so that the intended data transfer is completed ATTENTION Inactivity time is ONLY active when Connection Control see below is set to Any character Inactivity time Ignore jammed IP default No This option determi
164. sponds through the network either accepting or rejecting the connection attempt If the CN2600 receives the accept message from the RADIUS server the remote user is allowed to access the network Otherwise the CN2600 will either terminate the connection or attempt to connect again after a specified duration of time Setting up the CN2600 Setting up the RADIUS Server IP Address E 2 CN2600 Series User s Manual RADIUS Server Total Solution for Industrial Device Networking BO port 9 G Port 10 i 4 Gou Configuration 8 BNG Port 12 Port 13 RADIUS server IP GHG Port 14 RADIUS key B Port 15 UDP port 1645 7 B Port 16 RADIUS accounting C Enable Disable CJ Welcome Message Seem Managamant a EXSY Misc Network Settings E CJ Accessible IP List 0 SNMP Agent C2 pons CJ Host Table 18 Route Table fa User Table CJ Authentication Server CJ System Log Settings BJ Auto Warning Settings Y Maintenance HQ Certificate Gia System Monitoring CJ Save Configuration SGH Restart Authentication Server RADIUS server IP This is the IP address of the RADIUS server RADIUS key This is the password that is used to access the RADIUS server IUS server UDP port This is the RADIUS server s assigned UDP port RADIUS accounting This field enables or disables RADIUS accounting Serial Port Configuration RADIUS is an effective authentication method for
165. t For example C gt arp s 192 168 200 100 00 90 E8 04 00 11 12 Next execute a special Telnet command by entering the following exactly telnet 192 168 200 100 6000 When you enter this command a Connect failed message will appear as shown below c Command Prompt BS 1 TA s 192 168 206 100 00 90 e8 62 50 69 D Ndtelnet 192 168 266 168 6668 onnecting To 192 168 2606 166 Could not open connection to the host on port 6 MOB Connect failed 13 After the CN2600 reboots its IP address will assigned to the new address and you can reconnect using Telnet to verify that the update was successful Telnet Console Depending on how your computer and network are configured you may find it convenient to use network access to set up your CN2600 s IP address This can be done using Telnet A ATTENTION Figures in this section were taken from the CN2600 s Telnet console 3 4 CN2600 Series User s Manual Initial IP Address Configuration 1 From the Windows desktop select Start gt Run and then type telnet 192 168 127 254 in the Run window for LAN 1 or telnet 192 168 126 254 for LAN 2 If your IP address is different from the default setting use your IP address instead Click OK Type the name of a program folder document or Internet resource and Windows will open it for pou Oper telnet 192 168 127 254 Cancel Browse 2 The console terminal type selection is displayed as shown Enter 1
166. t and consequently the board may feel hot to the touch 2 2 CN2600 Series User s Manual Hardware Installation You should also observe the following common wiring rules e Use separate paths to route wiring for power and devices If power wiring and device wiring paths must cross make sure the wires are perpendicular at the intersection point NOTE Do not run signal or communication wiring and power wiring in the same wire conduit To avoid interference wires with different signal characteristics should be routed separately e You can use the type of signal transmitted through a wire to determine which wires should be kept separate The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together e Keep input wiring and output wiring separate e Where necessary it is strongly advised that you label wiring to all devices in the system Connecting the CN2600 8 16 s Power Connect the CN2600 s 100 240 VAC power line to its AC connector If the power is properly supplied the Ready LED will show a solid red color until the system is ready at which time the color changes to green Connecting to the Network Connect one end of the Ethernet cable to the CN2600 s 10 100M Ethernet port and the other end of the cable to the Ethernet network There are 2 LED indicators located on the top left and right corners of the Ethernet connector If the cable is properly connected the CN2600 will in
167. t1 and Ethernet refer to the built in Ethernet ports These settings configure the CN2600 to change the status of the relay output and alarm LED if the specified connection goes down Console web text login auth fail This field refers to a failed attempt to log in to a password protected CN2600 console IP changed With this option selected the CN2600 will attempt to send an e mail warning before it reboots after an IP address change However the CN2600 will reboot with the new IP address regardless of whether or not the e mail transmission is successful Password changed With this option selected the CN2600 will attempt to send an e mail warning before it reboots with a new console password If the CN2600 is unable to send an e mail message to the mail server within 15 seconds it will still reboot without sending the e mail 8 7 CN2600 Series User s Manual System Management Settings Serial Event Settings E Main Menu a A Port Event Settings Hipo ots Serial Port Event DCD changed DSR changed HE Serial Port Settings G LI Mail CTrap mail LTrap Bey Ea Manageo Port 2 Cl Mail Trap O Mail C Trap BC Misc Network Settings pie C mail Trap C Mail C Trap EY Auto Warning Settings Port O mail Ctrap O mail C Trap E 9 Event Settings Port 5 LI Mail Trap mail Trap Serial Event Settings Port 6 CI Mail C Trap CI Mail C Trap Z CJ E mail Alert Port 7 C Mail C Trap O Mail C Trap CJ SNMP Trap Port 8 Cl Mail Tr
168. te that Auto Network Re Connection must be enabled in order to use this function Fast Flush only flushes the local buffer For some applications the user s program will use the Win32 PurgeComm function before it reads or writes data After a program uses this PurgeComm function the CN2600 driver will continue to query the CN2600 firmware several times to make sure no data is queued in the CN2600 firmware buffer rather than just flushing the local buffer This design is used to satisfy some special considerations However it may take more time on the order of several hundred milliseconds than a native COM1 due to the additional time spent communicating across the Ethernet This is why PurgeComm works significantly faster with native COM ports on the PC than with mapped COM ports on the CN2600 In order to accommodate other applications that require a faster response time the new CN2600 driver implements a new Fast Flush option By default this function is enabled If you have disabled Fast Flush and find that COM ports mapped to the CN2600 perform markedly slower than when using a native COM port try to verify if PurgeComm functions are used in your application If so try enabling the Fast Flush function and see if there is a significant improvement in performance 9 15 CN2600 Series User s Manual Software Installation Configuration 10 The Serial Parameters page shown in the following figure shows the default sett
169. that will have advanced administrative features such as remote access policies or if you plan to add this server bo a domain Back Cancel start Z E Routing and Remote A GHE 1 56PM E 6 CN2600 Series User s Manual RADIUS Server 5 6 Select TCP IP protocol then click Next to continue o Routing and Remote Access Im De geal ae em 2x Routing and Remote Access Server Setup Wizard Action Tree l Remote Client Protocols Routing The protocols required for remote client access must be available on this server Verity that the protocols required on this server for remote clients are listed below Protocols Yes all of the required protocols are on this list No need to add protocols es Aistart Routing and Remote A Ee 2 01 PM Specify your IP address as shown on the following screens Routing and Remote Access Ir ee dl a mr vs Routing and Remote Access Server Setup Wizard IP Address Assignment TOU can select the method for assigning IP addresses to remote clients How do vou want P addresses to be assigned to remote clients 7 Automatically IF you use a DHCP server to assign addresses confirm that itis configured properly IF you do not use a DHCP server this server will generate the addresses 4 Back Cancel Pstart Z E Routing and Remote A BS 203 PM CN2600 Series User s Manual RADIUS Se
170. tings H Network Settings Hi Serial Port Settings BS System Managemant Sita Mie Nebsork Settings CJ Accessible LP List CI SNMP pam i DOS Host Tabla CJ Route Table CJ sear Tabla DO Authanteartion Sara L Srstem Log Sekine 10 XZ Auto Warning Settings AI Mastenanns M Ghbrway Destinatinn Netmask MibibriE Had land lani lani lani lani lani bani land o w BN h b hM v lan lana lani r lani HE Cerbheate 3 HGJ System Monitoring 1A lani CI Saya Conhguraton 14 lani HS Restart 15 land land land land land lant lani lani lami lani lanl lanl land land land lani lani S Kal la rel ted lad dl a lia Tee a e l tel ca ea a a ee Tel ia fm rea l al wal a lka Ta el ral rel lao 9 1 A21 GR K GG k K lab IW Kaka Had kaki LJ AK AA AAE 2 to IRJ d I Gb AA a LE IW VK ik HG lani 3 Submit at You are allowed up to 32 entries in the route table For each entry you must provide information on the gateway destination netmask metric hops and interface Gateway This is the IP address of the next hop router Destination This is the host s IP address or the network address of the route s destination Netmask This is the destination network s netmask Metric Enter the number of hops from the source to the destinationto allow the CN2600 to prioritize the routing of data packets if more than one router is available 5 10 CN2600 Series User s Manual Configur
171. tion status to affect the RTS or DTR signals Packet length default 0 The Packet length setting refers to the maximum amount of data that is allowed to accumulate in the serial port buffer before sending At the default of 0 for packet length no maximum amount is specified and data in the buffer will be sent as specified by the delimiter settings or when the buffer is full When a packet length between 1 and 1024 bytes is specified data in the buffer will be sent as soon it reaches the specified length Delimiter 1 and Delimiter 2 default None When Delimiter 1 is enabled the serial port will clear the buffer and send the data to the Ethernet port when a specific character entered in hex format is received A second delimiter character may be enabled and specified in the Delimiter 2 field so that both characters act as the delimiter to control when data should be sent ATTENTION In order to enable a delimiter packet length must be set to 0 Delimiter 2 should only be enabled in conjunction with Delimiter 1 and never on its own otherwise there may be data errors Even when a delimiter is enabled the CN2600 will still pack and send the data when the amount of data exceeds 1 KB Delimiter process default Do Nothing The Delimiter process field determines how the data is handled when a delimiter is received Delimiter 1 must be enabled for this field to have effect If Delimiters 1 and 2 are both enabled both characters must be receive
172. ty response to the program Under Classical mode the driver will not send the Tx Empty response until after confirmation is received from the CN2600 s serial port This causes lower throughput Classical mode is recommended if you want to ensure that all data is sent out before further processing 9 14 CN2600 Series User s Manual Software Installation Configuration FIFO If FIFO is Disabled the CN2600 will transmit one byte each time the Tx FIFO becomes empty and an Rx interrupt will be generated for each incoming byte This will result in a faster response and lower throughput Network Timeout You can use this option to prevent blocking if the target CN2600 is unavailable Auto Network Re Connection With this option enabled the driver will repeatedly attempt to re establish the TCP connection if the CN2600 does not respond to background check alive packets Return error if network is unavailable If this option is disabled the driver will not return any error even when a connection cannot be established to the CN2600 With this option enabled calling the Win32 Comm function will result in the error return code STATUS NETWORK UNREACHABLE when a connection cannot be established to the CN2600 This usually means that your host s network connection is down perhaps due to a cable being disconnected However if you can reach other network devices it may be that the CN2600 is not powered on or is disconnected No
173. u gt Network setting gt IP address After the address has been entered you will need to restart the CN2600 under Main Menu gt Save Restart The following instructions explain how to set the CN2600 s IP address through the LCM console L PA Press MENU to activate the Main Menu The first line of the display indicates the current menu and should read Main Menu The second line indicates the current selection and should read Server setting Use the UP and DOWN buttons to select Network setting Press SEL to enter the Network setting menu In the Network setting menu select IP config Don t forget to press SEL to confirm your selection In the IP config menu use the UP and DOWN buttons to select the option that matches your IP environment static DHCP etc Press SEL to confirm your choice You may also press MENU to cancel your selection and return to the previous submenu You should be back in the Network setting menu From the Network setting menu select IP address Use the UP and DOWN buttons to modify the digit currently selected by the blinking cursor Press SEL to move to the next digit Continue modifying the IP address until all digits have been entered If you make a mistake press MENU to cancel all changes and return to the Network setting menu You cannot go back one digit Once you have finished modifying the IP address your changes are saved but not in effect In order for your changes to take effect you will
174. up User Service or RADIUS is the standard for centralizing the authentication authorization and accounting of remote access users Here is a brief description of how RADIUS works When a user dials in to a remote access device that device communicates with the central RADIUS server to determine if the user is authorized to connect to the LAN The RADIUS server performs the authentication and responds with the result either accept or reject If the user is accepted the remote access server routes the user onto the network if not the server will terminate the user s connection The RADIUS server also provides accounting services if supported by the remote access server With RADIUS a network manager or ISP only needs to maintain a single central database against which all remote user authentications take place This greatly eases the management burden associated with administering a large number of dial in users Client Server Architecture RADIUS is a type of client server software Communication servers such as the CN2600 play an active role whereas RADIUS servers are passive When a remote host is connected to the CN2600 the host is prompted to enter a user ID and password After receiving the user ID and password the CN2600 sends the information to a defined RADIUS server Up to this point the remote user is still unable to access the network The RADIUS server compares the user ID and password with its internal database and re
175. ursor will jump to the next line but not move lt LF gt horizontally Dial In Out Applications PPP Mode MOXA 4 Main Menu A CJ Overview Operation Modes a Basic Settings acy Network Settings Port 1 HI Serial Port Settings Application Dial in out IT Port 1 Mode IPPP fw E Operation Modes Destination IP address B 7 CJ Communication P f HB Source IP address LI Data Buffering Lo Poa 4 IP netmask Modem Settings ant H O Opi egg Port 2 TCP IP compression O Enable Disable O port 3 Inactivity time o 0 65535 ms BG Port 4 Link quality report O Enable Disable HE Port 5 Outgoing PAP ID maa ap an a Port 6 PAP password i Bl T A a POR Incoming PAP check None BI Ports U E 7 Disconnect by None v CJ Welcome Message pez A j P1 Clipe ips C P4 Ops TIP6 CIP ips L System Management Apply the above settings to HE System Monitoring Call ports CJ Save Configuration HG Restart w lt gt PPP provides standard PPP service for both dial in and dial out Destination IP address This is the IP address of the remote dial in dial out server 6 24 CN2600 Series User s Manual Configuring Serial Port Operation Modes Source IP address The Source IP address is IP address assigned to this serial port IP netmask The IP netmask defines the netmask also known as the subnet mask for the PPP connection TCP IP compression default No The setting of this field d
176. will be ready to map the terminal server serial port to the system tty port Mapping TTY Ports Make sure that you set the operation mode of the desired CN2600 serial port to Real COM mode After logging in as a super user enter the directory usr lib npreal2 driver and then execute mxaddsvr to map the serial port on the target terminal server to the host tty ports The syntax of the mxaddsvr command is as follows mxaddsvr Terminal Server IP Address Total Ports Data port Cmd port The mxaddsvr command performs the following actions 1 Modifies npreal2d cf 2 Creates tty ports in directory dev with major amp minor number configured in npreal2d cf 3 Restarts the driver Mapping tty ports automatically To map tty ports automatically you may execute mxaddsvr with just the IP address and number of ports as in the following example cd usr lib npreal2 driver mxaddsvr 192 168 3 4 16 In this example 16 tty ports will be added all with IP 192 168 3 4 with data ports from 950 to 965and command ports from 966 to 981 Mapping tty ports manually To map tty ports manually you may execute mxaddsvr and manually specify the data and command ports as in the following example cd usr lib npreal2 driver mxaddsvr 192 168 3 4 16 4001 966 In this example 16 tty ports will be added all with IP 192 168 3 4 with data ports from 4001 to 4016 and command ports from 966 to 981 Removing Mapped TTY Ports After lo
177. y settings Add this Web site ta the zone http 1192 168 127 254 Web sites http ITP update microsoft com https update microsoft com http windowsupdate microsoft com https windowsupdate microsoft com http jigo microsoft com http msdn microsoft com S Require server verification https for all sites in this zone Close After adding the CN2600 s IP address as a trusted site you should be able to view the web console by entering the CN2600 s IP address in your browser s address bar Opening the Web Console Open your web browser and enter 192 168 127 254 in the website address line This is the default IP address for the CN2600 1f a new address has been assigned enter the new address instead Press ENTER to load the page A ATTENTION The examples and figures in this chapter use the CN2600 factory default IP address of 192 168 127 254 If you have assigned a different IP address to your CN2600 be sure to adjust accordingly when following these directions Please refer to Chapter 3 Initial IP Address Configuration for details on how to configure the IP address 3 Enter the console password if prompted This will not apply if you did not enable password protection for your CN2600 The password will be transmitted with MD5 encryption over the Ethernet Web Console Login Lemans Password 5 4 CN2600 Series User s Manual Configuration with the Web Console ATTEN
178. ynDns or g C 2 CN2600 Series User s Manual Dynamic Domain name Serve DDNS default Disable Use this field to enable or disable DDNS Server address default DynDns org Currently DynDns org is the only option available for Server address Host name In this field use the name that you created on www dyndns com The CN2600 will update the DynDNS server with this host name Username This is the user name used for update authentication Password This is the password used for update authentication C 3 D Well Known Port Numbers In this appendix we provide a list of well known port numbers that may cause network problems 1f you set the CN2600 to one of these ports Refer to RFC 1700 for well known port numbers or to the following introduction from the IANA The port numbers are divided into three ranges the Well Known Ports the Registered Ports and the Dynamic and or Private Ports The Well Known Ports range from 0 through 1023 The Registered Ports range from 1024 through 49151 The Dynamic and or Private Ports range from 49152 through 65535 The Well Known Ports are assigned by the IANA and on most systems can only be used by system processes or by programs executed by privileged users The following table shows famous port numbers among the listed well known port numbers For more details please visit the IANA website at http www iana org assignments port numbers Kaea xam CN2600 Series User s
179. ynamic Host Configuration Protocol DHCP Sene Authentication Service HUMD C REC over HTTP Proxy 0 0 MB O A Simple TCP IP Services 0 0 MB O JB windows Internet Name Service WINS 0 5 ME Description Enables authentication authorization and accounting of dial up and VPN users IAS supports the RADIUS protocol Total disk space required 14 6 ME Details Space available on disk 1914 5 MB Cancel E 9 CN2600 Series User s Manual RADIUS Server 4 After the installation is complete click Administrative Tools and run the Internet Authentication Service This will open the following window Internet Authentication Service File Action View Help 3 a ene Welcome to Internet Authentication Service Ha Remi New m Cnr Use Internet Authentication Service 145 to authenticate Refresh authorize and account For dial up YPN wireless and Ethernet connections to your network You can also configure LAS to Forward authentication requests to any access server that is compatible with Remote Authentication Dial In User Service RADIUS Help To configure 145 to read the remote access properties of user accounts in Active Directory on the Action menu click Register Server in Active Directory For more information about setting up 145 deployment scenarios and troubleshooting see Help New dient PP 5 Select New RADIUS Client to add a new RADIUS client You will then be able to be
180. ystem Monitoring ia Save Configuration Packet length Delimiter 1 Delimiter 2 HJ Restart Delimiter process Force transmit Apply the above settings to lt Socket E TCP Server 7 0 99 min 0 0 65535 ms liv Enable Disable Enable Disable 4001 966 RTS O always low always high DTR O always low always high 0 0 1024 00 Hex Cl Enable 00 Hex Cl Enable Do Nothing Processed only when Packing length is 0 o 0 65535 ms P1 Flpa C p3 Cip4 Ops C P6 CIP COPs O All ports v TCP alive check time default 7 min This field specifies how long the CN2600 will wait for a response to keep alive packets before closing the TCP connection The CN2600 checks connection status by sending periodic keep alive packets If the remote host does not respond to the packet within the time specified in this field the CN2600 will force the existing TCP connection to close For socket and device control modes the CN2600 will listen for another TCP connection from another host after closing the connection If TCP alive check time is set to 0 the TCP connection will remain open even 1f there is no response to the keep alive packets Inactivity time default 0 ms This field specifies how long the CN2600 will wait for incoming and outgoing data through the serial port before closing the TCP connection The TCP connection is closed 1f there is no incoming or outgoing data through the serial port for the spe