1. to the control panel when Fig 2 General wiring diagram when switched input control Telephone number Enter the GSM numbers of mobile phones to which the module will send SMS messages and or will make calls Module parameters can be set or the state of Setting of operating parameters with a computer output OUT1 can be controlled by sending SMS messages only from phones having these numbers GSM numbers should be entered with international country code We recommend using program CG5config for setting up module CG5 operating parameters This will allow without the plus sign setting parameters of the equipment quicker and easier The program can be found on website www trikdis It o By checking boxes below the GSM numbers you can choose how each recipient will be alerted and which type 1 Connect the module CG5 with computer USB port Computer must have appropriate USB drivers of messages will be sent to them installed SMS SMS messages will be sent when appropriate input circuit is broken box E and Note If the module CG5 is connected to a MS Windows OS computer for the first time a new Found New Hardware Wizard restored box R window should open for installing new USB drivers This window means that a USB driver has to be installed in order to Call A call will be made to alert that appropriate input circuit is broken box E and connect to the module CG5 properly Download the USB driver file USB_COM inf from website www trikdis
2. GSM module CG5 F TRIKDIS Module components v 2 XX Trikdis JSC i Draugyst s st 17 Installation manual LT 51229 Kaunas Email info trikdis lt www trikdis It 1 Terminal block for external contacts 2 SIM card holder 3 USB port for setting up parameters 4 GSM antenna 5 indicator Network 6 indicator Data 7 indicator Power Safety requirements Liability restrictions Please read this manual carefully before using the security module CG5 Security module CG5 shall be installed and maintained by qualified personnel having specific knowledge regarding the functioning of GSM devices and safety requirements The device must be disconnected from power supply source before starting device installation Module CG5 shall be mounted in places with restricted access and in safe distance from any sensitive electronic equipment The device is not resistant to mechanical effects dampness and hazardous chemical environment Liability restrictions When buying the Device the Buyer agrees that the Device is a part of a security system of premises which sends messages about security system status The Device when installed does not diminish the probability of burglary fire intrusion or other p ET eeceet E A e L i E 12 V power supply clamp breach of premises Peon ene n nee eee Se ee ee 4 f COM l Common clamp f UAB TRIKDIS is not responsible for burglary fire o
3. It In the wizard window select the function Yes this time only and press the button Next When a new window Please choose your search and installation options will open press the button Browse and select the place where the file USB_COM inf was saved LP SMS messages will be sent when informing about disturbances in power supply chain Follow the remaining wizard instructions to finish USB driver installation restored box R Test Module shall send test messages to the recipient according to the time period set in 2 Start the program CG5config the field Test every ACK Module CG5 shall send confirmation about command execution to the recipient who 3 Select the program directory Settings eenen ad cons a In the drop down list Port select the port to which the module is ia a o i P 8 Press the button Save F6 and set configuration will be uploaded to Module CG5 Language English SAAN VEAN 2 Note specific port to which the device is connected is shown only when 9 Press the button Disconnect F8 and unplug USB cable the device is properly connected A set configuration file can be created with extention gst and saved in the computer by the pressing the In the drop down list Language select the desired software button Save F5 The file as a templet can be used in the future language 4 Press the button Connect Disconnect F2 F8 If you need to restore Module CG5 default parameters press the button Resto
4. ME 1234 YYYY MM DD 12 00 00 _ g IN3 ALARM Zone 3 RESTORE Zone 3 i 8 l PSW Setting of password IN4 ALARM Zone 4 _ RESTORE Zone 4 7 1 New PSW g New password 4 digit i Le send eae SEA i_ For example PSW 1234 4321 Event Event message Restore message r a o o o RESET a 1 a 1 Modul le reset eS aaa i LP Power Failure Power Failure restore i i i For example RESET 1234 i T Test PaRa A 7 SR rere tere sree ig Olga sella ae NA aa pir 8 hanes egnen enema e ncaa ees i i i 10 INFO Request for info about module state 441234567830 eee ees De erate 1 Forexample INFO 1234 eee SMS Call a i SLEEP Stop sending of SMS that have been unsent till RESET x z y i command 4 vu m 4 eee chee eee ee eee eee eee eee eet For example SLEEP 1234 eee v v M m m v v v v v v v m mM M Remote switching of PGM output OUT1 N Iv v a v v In order to change state of output OUT1 you need to send an SMS message to the SIM card GSM number of the z Module Examples of SMS messages are provided in the table below i Note All commands have to be written in capital letters oa SMS syntax Hoot ak ee Meaning nna Patabo tt 1 Zone alarm restore events can be described with a text Enter your texts in appropriate text boxes When input ae eee eee circuit is disturbed an SMS message will be sent with text from the appropriate text box Event message When e Saas se
5. ages Take notice if time shown in the received Call duration is 20 seconds l SMS message corresponds to the time of SMS messages will include an event time stamp when the module internal clock is set with an SMS message the actual event Output OUT1 is open collector type and can commutate direct voltage up to 30 V and current up to 1 A If the output is set to Siren mode after disturbing the input circuits the output will be activated for two minutes Sending interval for periodic Test messages is from 1 to 240 hours Text of Test message can be customized Wiring diagrams Module monitors power supply voltage When voltage drops below 11 5 V a message informing about the drop in voltage is sent Message is also sent when voltage restores to 12 6 V 12 V COM Technical parameters 60 100 mA stand by mode Up to 250 mA transmitting mode Control panel terminals ON OFF iaei aa a SSS SS SSS Se aaa a constant input control mode 24 h is set mode Control panel is set Memory eee Up to 60 messages eee IPU a aaaaoooaoooaa 1 A1 NC NO EOL 2 2 KQ l aooooaoooooaa00n nni device Output aaa 1 OC type commutating up to 30 V voltage and current up to 1A __ _Test message sending interval ______ 05 240N eee eee Setting configuration Through the USB port or with SMS messages Operating environment ae J From 10 C to 50 C with relative air humidity 80 when 20 C 4 Fig 1 General wiring diagram
6. b SIM cord PIN code reduest must be Output can be controlled with an SMS message disabled Operating parameters can be set with a program CG5config or by sending SMS messages The location and dimensions of holes to be drilled in the casing for fastening the module and antenna 3 Fasten the module to the control panel metal casing by using M3x6 screws or an adhesive fastening tape Description of Device Operation Module CG5 can be set to operate in one of the two modes a Constant input control mode 24 h After the control panel has changed the state of its PGM output this causes module input circuit breaking Module CG5 immediately sends an SMS message with pre set content to a mobile phone When the input circuit state restores the module will send an SMS message about this event General wiring diagram is given in Fig 1 a 9 ee eee b Switched input control mode Control panel When operating in this mode input MCI functions 1 4 Screw the GSM antenna on as an input status controller While input MCI is connected with COM disturbances in inputs ee eel aie ee eae ae Eid es i ie dee ie oe ee 4 ne 5 Connect the Module to other security Possible Wiring diagrams are given in IN1 IN4 are ignored and SMS messages about them are not sent After the MCI input circuit has i i l l i system devices according to the schemes page 5 been broken the module CG5 will send an SMS message informing that the input
7. he new box Remember Then the Access code window will not open version of Module firmware will be displayed in status bar of the program CG5config Now you can set j _ Remember when connecting to the module for the next time additionally configuration according to the manner described in previous chapter If you don t need this press the button Disconnect F7 and unplug USB cable 6 Set the following parameters in the directory SMS reporting CG5config i m x Sarr Setting of operating parameters with SMS messages ___Discornectirzira __ Pean wiers onra saersi Some Module operating parameters can be set by sending SMS messages from authorised phone to the GSM He iaia number of the SIM card inserted in the Module If function ACK for confirming SMS commands is set Module o Access Code will send back SMS messages with confirmations that COMMAND OK Wrong COMMAND Wrong Account name CG5 PASSWORD Wrong DATA SMS syntax lt Command gt space lt Password gt spaces lt Data gt For example SETN 1234 PHONE1 37068700000 SMS text encoding fi ENGLISH WIN1252 7 Here SETN command Operation mode fi 24h NC x 1234 password 0 Remote control by SMS tl a EEE z PHONE1 37068700000 data Test time fo ah Note All commands in SMS message have to be written in capital letters SerNo i Command i Content Meaning aaan 1 SETL Setting of language ENG English i RUS Russian i LIT Lithuan
8. ian eee bee cece eee e ee doce ceeeeeeeeeee j For example SETL1234ENG lee 2 SETN Entering of recipients telephone numbers PHONE1 3 70xxx 1 GSM number Save access code Read after connection Restore defaults settings Restore F11 PHONE2 370xxx ane GSM number PHONE3 370xxx 3 GSM number Dev CG5v2 SN 000594 Ver 2 50 Connected 4 GSM number For example SETN 1234 PHONE1 37068700000 Deleting of recipients telephone numbers PHONE4 3 70xxx Access code Default access code 1234 must be changed to one known by you and other authorised persons only This code is used for setting operating parameters of the PHONE1 DEL 1 GSM number module and or to control the state of output OUT1 with SMS messages When PHONE2 DEL 2 4 GSM number changing the password enter a desired four digit sequence PHONE3 DEL 3 GSM number th Account name If desired enter the name of the object Account name will be included in SMS PRONES DEL 4 GSM number ee oh eee eee ee dees eee ee ee _ For example SETN 1234 PHONEI DEL LL er 3 SETE Distributing of messages by their type SMS text encoding Select the format of SMS text encoding in the drop down list TEST s Enabling sending of Test message Operation mode Select the desired module CG5 operating mode either 24 h or Control panel f there ae g aire e avout i is set NO or NC type all five inputs will respect
9. ient microcontroller I is functioning properly i Power supply is not sufficient lt 11 5 V microcontroller is properly functioning I I I I a I I I I NR ee he ee aa ee eee Mee wise Ne pig Fe gs yin cg ee ee ee 71 I I I a Package contents Programming mode Sends SMS messages if one of the input circuits is broken at least T Every SMS message contains exact event time stamp E auaiasaiaia aa uae Jetececes PL Eee a eer rrr a ontact a service provider in order to receive a SIM card We do not recommend using pay as you go SIM cards turn The Module CG5 1 pc LScoS2 oS Sa Soe coa SSS See ee nee eee e eer eee ee rene SSS see See Se ese GSM antenna of straight type 1 pc Two sided adhesive tape 10 cm 1 pc Module installation Actions Notes i GSM module CG5 e A EE E A ab Set Module operating parameters by Follow instructions given in chapter CG5 is a device which sends SMS messages with text to 1 4 mobile phones about disturbing the security using the CG5config configuration Setting operating parameters with a system of the premises Features software installed in a computer computer page 5 a Supports texts about events are set with Lithuanian Latin or Russian characters 2 Insert an activated SIM card User can be alerted about the sending of SMS messages with a phone call Power supply voltage control LED indication about aevice operation status and GSM signal strength
10. ively become either NO or NC If there SMS i Enablingcallingireventhapoens is set EOL type inputs IN1 IN4 will become EOL 2 2kQ and the input MCI NC Enabling SMS sending if event happens Output Select the desired output OUT1 operating mode If you connect a siren to the output For example SETE 1234 PHONE1 TEST ON ACK ON select the option Siren If you would like that after receiving a command with SMS PENERE ee eee eran Sree eee Soe ee L 4 TXTA Setting of object name message the module would change the state of its output select the option Remote trol by SMS e e n 2 eee D a SC I e L PEES l 5 l TXTE i Customising of SMS with alarm text Test time Enter a desired time period according to which the module will send a periodic Z1 lt Text gt Z41 Z6 input number message with text entered in the row Test i p aeeoe i i _ AE EEA E A E _For example TXTE 1234Z1 ALARM in Zonet ls Call When event occurs module will call to User pre set number of times g IXTR i Customising of SMS with restore text 7 Choose the directory SMS reporting and set desirable parameters used for reporting pee Ad EOnpuCnumber 2 Lee eee eee ened gO ec _For example TXTR 1234 Zi Restore Zoned an Input _ Event message Restore message i 7 i TIME i Setting of internal clock i Settings IN1 ALARM Zone 1 RESTORE Zone 1 toa ee Firmware IN2 ALARM Zone 2 RESTORE Zone 2 SEBES S en eee eee ESEE gS SEESE aF or ape TI
11. me sia aaas De a eee 1234 default password Instead input circuit is restored from the text box Restore message Texts which describe events in power supply OUTBUT 1234 PULSECOOE Output tu macau pai on ONcreriera mecca of this enter your chain can be entered in the box LP There can be entered desirable text which will be included in periodic Note Output state can be switched only when operating mode of the Module is set as 24h and output operating mode is set message in the box Test as Remote control by SMS
12. r alain ae ire a aati ak BRE Sar ER a el E GSM network status Yellow flashing Number of yellow flashes represent GSM UAB TRIKDIS is not responsible if GSM GPRS Internet services are not provided to the Buyer and or User of the Device or signal strength were cancelled and any direct or indirect damages were incurred thereof YellowON oe SMS message is being sent aaa i UAB TRIKDIS is not responsible for any direct or indirect damages incurred by the Buyer and or User of the Device due to loss o Indicator Data displays o 7 l l Green ON l l l l l l l l l l l l l l l l lt l i Memory contains unsent messages l l l l l l i of electricity data buffer status i Red ON Messages are unable to be sent wee ee ee eB ee ee ee X X eB e e eB ee eB ee ee ee ee UAB TRIKDIS is not liable if Device firmware versions were not updated by the Buyer and or the User on time ___ Red flashing j___ Module configuration is incorrect wee eee ee ee ew ew eB Se ew ew ew ee eB ee eB ee ee ee eB ee ee ___ Red flashing rapidly SIM carderror 22222222222 User manual of the Device can contain technical inaccuracies grammatical or typographical errors UAB TRIKDIS reserves the pvr rr rrr rrr errr rrr rte i aa Indi rP ispl right to correct update and or change information in the installation manual NAICALOF POWET eels all power supply status functioning of microcontroller and programming status Power supply is suffic
13. r any other breach of Buyer s and or User s premises and is not liable for D INL N4 nT Input clamps NC type oo any direct or indirect damages incurred thereof Bo OUTDO a Output clamps OC type ep a When buying the Device the Buyer agrees that the Device supplied by UAB TRIKDIS fully meets his requirements for i ee com o 7 Common clamp ae intended use E MCL __ Programmable input clamp __ UAB TRIKIDIS provides no guarantees that the Device shall function as declared if the Device is installed and used not according to its original purpose user manual and relevant electronic and technical conditions UAB TRIKDIS is in no way associated with GSM GPRS Internet service providers operators thus UAB TRIKDIS is in no way Light indication responsible for any defects in Device operation if they have occurred because of the loss of GSM GPRS Internet connection or eee eee eee eee eee Adeeeeeredeasee users es ereeasesee ere bereeeeebeteeeeeGeeeeeGeees because of other defects in the service provider network a LED __________ Operation tee eases Description l Indicator Network l Green flashin l Is registering to GSM network i UAB TRIKDIS has no control and is not responsible for the prices and marketing of network services provided by the Ee eee Seti eee Spe a ame 1 displays connection with Green ON 1 Connection to GSM network at presentis GSM GPRS Internet service providers laa i
14. re F11 and press the button Confirm when request window newly opens Module CG5 default operating parameters can be restored any When the module CG5 is connected to a computer module LED time before unplugging the USB cable Fle Devices About indicator Power should flash green and yellow in turn and CG5config status bar should indicate connection status Beige alee ice li Connected Further information about the connected module Module firmware version updating should be displayed in status bar SMS reporting When the manufacturer adds new features to the Module CG5 firmware of the previously bought CG5 can be Settings Dew CG3 Module type updated Firmware l SN 000143 Module serial number 1 Download the latest CG5_xxx prg update file from the website www trikdis lt Ver 2 0 Firmware version installed in the module 2 Connect the Module CG5 to a computer and start the CG5config program Select the directory Firmware 5 Press the button Read F7 in program CG5config and select the downloaded update file CG5_xxx prg x Enter your access code and press the button OK in the opened 3 Firmware update will start after pressing the button Start F9 Wait until Progress bar reaches 100 z window Access code default access code is 1234 then press the button Disconnect F8 and unplug the USB cable If you want CG5config to remember your access code check the 4 Plug the USB cable back in and press one by one the buttons Connect F2 and Read F7 T
15. s are Under siven below Control and disturbances in inputs N1 N4 circuits will no longer are ignored When circuits of beeps E Sac see nsec yess seesenaeseseaesaeen ee AARAA AARAA eee et et et et et ete ete ate et a eee eee eee ee eee ate ee E the inputs N1 N4 are broken module will send messages about these events 6 Switch on the security system power Output OUT1 can be used to connect a siren Siren is activated when the module CG5 registers an event supply l Switching off mode Under Control deactivates the siren as well Switching on the mode Under Control is a a ee E a a al 1 i ffici i Light indication i fi Ilow flashes of indi N k Module CG5 has five NC NO EOL 2 2 kQ type inputs When operating in 24 h mode module MCI input is the SHUUICHI ACCO ain TO LIEMEINAICANGN ee wal ne weleator ee a If GSM signal strength is not sufficient fifth 24 hour managed input and when operating in Control panel mode it operates as a controller for the i i i use other antenna type i other four inputs SRON APEERE EEA SEEE E T E A eee SMS messages can be sent to 1 4 mobile phones It is possible to configure how User can be alerted and what 8 Set the Module internal clock Send SMS message to the Module with type of messages should be sent to every phone information about time Module can 1 9 times call to every chosen phone from the list to alert Users about events in security system 9 Check if the module sends SMS mess