1. 2 5 Owx Ze H H v ge Pre EPX 420D 4CH Switeh Pack LATCHING RELAY 100 240V 59 60Hz 20A4x4 EPX 410D 420D 430D 810D 820D 830D EUM A Lite Puter 3 Operations 3 1 lnitialization Hold A and v at the same time and restart the device The LED screen shows Fe Press DMX to initialize the device KEE 3 2 DMX Address Setting Standard DMX console can output 512 channels and EPX 420D can use 4 continuous channels as the output channel The number of the first channel of these 4 continuous channels is start channel address Press DMX A or V to change DMX address For example change DMX address from 001 to 003 Note Press DMX once to check the DMX address 3 3 Channel Output Status In the main screen press lt or gt to enter channel status check First channel is on ON mode Second channel is on OFF mode EPX 410D 420D 430D 810D 820D 830D EUM A 7 Lite Puter 3 4 DMX IN Setting Press FCN to shift to DMX IN setting after initialization turns d OF Press A or V to adjust and DMX to confirm and back to time screen d 0F Receive DMX signal d HI Not receive DMX signal 3 5 Delay Time Setting Delay time is the time between channels to be reacted by the control signal For example if delay time is set as 0 5 second and EPX 420D received a signal to turn off all channels EPX 420D will turn off 1st channel immediately and then turn off 2 channel after 0 5 sec
2. 810D 820D 830D EUM A 13 Lite Puter 4 4 Primary Secondary Scene and Scene Overlap ON OFF Overlap Scene Function On usual when user recall a scene the previous scene will be replaced This function is to overlap output of SC5 5C6 to any other scene which means the previous scene should not be replaced but appears the effect of several overlapped scenes For example SC2 the first channel of EPX 420D is OFF SC5 the first channel of EPX 420D is ON When overlap SC5 to SC2 the first channel is ON Primary and Secondary Scene Function On usual press a scene button 1 6 on the control panel the corresponding scene will be recalled if you press the same button once again it will be the same scene When this function is on press a scene button the corresponding scene will be recalled and press the same button again another scene will be recalled Press the scene button to shift the two scenes alternatively These two scenes are recalled by the same button is the primary and secondary scene For example Channel 1 and 2 control curtain A Channel 3 and 4 control curtain B Primary scene 1 SC1 CH1 is ON CH2 is OFF CH3 is ON and CH4 is OFF Secondary scene 1S SC1S CH1 is OFF CH2 is ON CH3 is OFF and CH4 is ON Press SC1 button curtain A and B go up press the button again curtain A and B go down The curtain can t be stopped in the process of going up or going down NOTE when the current scene is OFF pre
3. Lite Puter User Manual EPX 410D 420D 430D 810D 820D 830D 4 8 Channel Switch Pack Series EPX 410D 420D 430D 810D 820D 830D EUM A Lite Puter Index tBerre INS LAM ANOT nen EE 3 2 IM OCI eege 3 Re 3 eer eren E 3 SEENEN 4 E FAC ONS E 5 2 9 Wiking Diagram One Channel EE 6 OO Ci e E 7 SAA MAIZ MON 7 3 2 DMX AOGKESS ee EEN 7 3 0 Channel VU P ESIA S da 7 SB DN SENO ak 8 3 0 Delay TIME Send ni ia 8 376 Channel Mode Se ING EE 8 3 7 Channe s Switching on Level Geng 9 E Ee De Bn EE 9 AEDA SV Sia acia A ii s 10 ZOE MO r atea sokl 10 sl IE lan eeng Lee EE 12 9 2 ZONE NUMDBEHSEMNY saka A Ee 12 ApS SCONE dV 6 ad A dE ala 13 4 4 Primary Secondary Scene and Scene Overlap ON OFF een rnrn 14 doba SS TG A E U O eg 15 4 5 1 Enable Disable Partition Function ccccccccccecceeeeeeeeeeeeeeeaeeseeeeeeeeesaaeaaeeeeeseeesaaaneeeeeees 16 A552 O SEMO 5352 k tet deta a Oral eae ee Lees 16 Billek War 9 EE 17 EPX 410D 420D 430D 810D 820D 830D EUM A 2 Lite Puter 1 Before Installation 1 Working environment Temperature 0 C 40 C Humidity 20 80 2 Please check EDX wiring guide on Lite Puter s website http www liteputer com tw tech_guide asp 2 Introductions 2 1 Features e EDX and DMX 512 e Din rail mounted e 4 channel dry contact for EPX 410D 420D 430D 8 channel dry contact for EPX 810D 820D 830D Each channel can be manually switched on off individually e Fad
4. e time of each scene can be set e Upto 99 zones e Delay time setting 0 15 10S for each channel to avoid current surge e Connectable to ECP series control panels 2 2 Specifications 1 AC Input AC 100 240V 2 Output EPX 410D 10A per channel EPX 420D 20A per channel EPX 430D 30A per channel 3 Protocol DMX 512 EDX 4 Dimensions EPX 410D 420D 430D 162 W x 90 H x 61 55 D mm EPX 810D 820D 830D 234 W x 90 H x 61 55 D mm 5 Weight EPX 410D 420D 430D 0 60Kg EPX 810D 820D 830D 0 90Kg EPX 410D 420D 430D 810D 820D 830D EUM A Lite Puter 2 3 Dimensions gt WARNING 1 gt HIGH VOLTAGE 90 00 mm DMX FCN 4 H v Lite Puter EPX 420D 4CH Switch Pack LATCHING RELAY 100 240V 50 60Hz 20Ax4 EN E GIS lt lt lt 162 00 mm 61 55 mm WARNING tl gt ZN HIGH VOLTAGE OFF 1 2 8 DMX FCN lt gt v Lite Puter EPX 820D 8CH Switch Pack LATCHING RELAY 100 240V 50 60Hz 20Ax8 90 00 mm 234 00 mm 61 55 mm EPX 410D 420D 430D 810D 820D 830D EUM A Lite Puter 2 4 Functions DMX FCN af b v EPX 420D 4CH Switch Pack LATCHING RELAY 100 240V 50 60Hz 20Ax4 GND v DMX to set DMX address Channel ON OFF FCN function selection exit without saving lt gt a v e EDX DMX 512 EDX 12V indicator EDX DMX 512 signal indicator EPX 410D 420D 430D 810D 820D 830D EUM A Lite Puter 2 5 Wiring Diagram One Channel 1
5. ld be 01 01 01 05 01 09 01 13 separately STEP 1 In the main screen zone and start channel setting is shown as below Press A or v to change zone number up to 99 zone After setting press DMX to save STEP 2 Press right button once shift to start channel setting Press A or v to modify the start channel address up to 99 channel After setting press DMX to save For example change channel address from 02 to 03 EPX 410D 420D 430D 810D 820D 830D EUM A 12 Lite Puter 4 3 Scene Save and Recall STEP 1 In the main screen press 4 or gt to select a channel Here we select channel one STEP 2 Press A or v to set the level of channel 1 Here we press A to make the output of channel one to 100 STEP 3 Press lt or M to select other channel Repeat step 2 and 3 to edit the scene STEP 4 Press DMX LED shows lt means that the current scene is going to be stored in scene 01 STEP 5 Press A or v to select a scene number to store the current scene If you enabled Primary secondary scene function refer 4 4 you can select secondary scene to store the scene SE 15 Secondary Scene 1 STEP 6 Press DMX to save the scene When Primary Secondary scene is enabled refer 4 4 Secondary scene SC 1S SC6S can be edited or recalled when Primary Secondary scene is disabled only primary scene SC 1 SC6 can be edited or recalled EPX 410D 420D 430D
6. ntrolled by ECP panel in zone 2 Load 1 2 Load 3 4 fone 1 7 fone ECP Panel ECP Panel Zone 01 Zone 02 d CIC 4 Channel E E E E a e Ss EDXEPX Device CC FDX Signal EPX 410D 420D 430D 810D 820D 830D EUM A 15 Lite Puter 4 5 1 Enable Disable Partition Function STEP 1 Press FCN several times until LED shows It means partition function is disabled Press A to turn on partition function 4 5 2 Partition Setting STEP 1 Press FCN several times until LED shows It means that channel 1 belongs to zone 1 STEP 2 Press A or v to change the zone number which channel 1 belongs to Here we make channel 1 belonging to zone 4 by pressing A 3 times STEP 3 Press gt to select start channel of the zone 0 1 means the start channel is 1 STEP 4 Press A or v to select a start channel number STEP 5 Press 4 twice to select channel digits Then press A once to select channel 2 It shows that channel 2 belongs to zone 1 STEP4 Repeat step 2 3 45 to set zone number and start channel of each channel EPX 410D 420D 430D 810D 820D 830D EUM A 16 Lite Puter Limited Warranty 1 Lite Puter is only responsible for the product itself 2 Lite Puter guarantees to keep Lite Puter s from manufacturing defects within a year since the distributing date 3 Lite Puter does not offer on site service If the defects appears in Lite Puter s product
7. oads are turned on for some time By changing channel mode from switch to fade mode can solve this issue If you want the switching loads to be turned on when dimmable loads are turning to 80 you can simply change the channel mode to fade mode 3 6 and make switching on value to 80 3 7 In some applications turning switching loads on instantly might be preferable Setting channel mode as switching mode would be better 3 8 Software Version Check In the main screen press FCN in succession to check the software version EPX 410D 420D 430D 810D 820D 830D EUM A 9 Lite Puter 4 EDX Systems EDX EPX devices can work either in DMX 512 mode or EDX mode DMX 512 Mode EDX EPX devices can be controlled by DMX 512 controllers EDX Mode EDX EPX devices can be recalled its stored lighting scenes by connecting to ECP scene control panels Please refer EDX wiring guide on Lite Puter s website http www liteputer com tw tech guide asp 4 0 EDX Mode EDX is a protocol specifically designed for architectural and environmental lighting applications EDX EPX dimmers switches or devices are able to store scenes in themselves Each EDX EPX device or ECP panel can be specified by a zone number The scenes stored in EDX EPX devices can be recalled by ECP panels with the same zone number For example EDX EPX devices configured as zone 1 can be controlled recall scenes by ECP panel configure as zone 1 EDX EPX devices configured a
8. ond and then turn off 3 channel after 1 second and then turn off 4 channel after 1 5 second The function is to avoid large surge current if all relays activated simultaneously STEP 1 On the main page press FUNC eight times to enter delay time setting It means the delay time is 0 0 second STEP 2 Press A or V to change delay time range from 0 0S 10S STEP 3 Press DMX to save or press FCN to cancel 3 6 Channel Mode Setting There are two modes for channel status shown as below Switch Mode only two status 0 and 100 Fade Mode the value can be adjusted from 0 to 100 EPX 410D 420D 430D 810D 820D 830D EUM A 8 Lite Puter 3 7 Channe s Switching on Level Setting STEP 1 In the main screen press FUNC to enter the switch on value setting It means the channel will be switched on when its level is 52 STEP 2 Press A or v to set the switching on level from 10 to 90 STEP 3 After setting press DMX to save The switching off level is 5 lower than switching on level For example if switching on level is 90 the switching off level will be 85 By default the channel mode refer 3 6 is switch mode In switch mode If you press up down buttons or recall a scene on an ECP panel it will instantly turn on the channels in EDX If the ECP panel also controls other dimmable loads it might be not desirable to have some switching lamps instantly turned on but other dimmable l
9. please deliver the product to local distributors or to Taipei headquarters 4 The warranty does not cover a Any fault caused by false usage imprudence collision inadequate installation or adjustment insufficient ventilation or improper repairs b Force majeure factors flooding earthquake thunder volcanic eruption tsunami or other factors beyond Lite Puter control c The cost of installing reinstalling adjusting repairing or reprogramming the product d Other products or devices which are offered by Lite Puter or not by Lite Puter 5 Lite Puter does not warrant the product will operate without interruption or being free of error Taipei Lite Puter Enterprise Co Ltd 11F No 189 Ganggian Rd Neihu Dist Taipei Taiwan 11494 Tel 886 2 2799 8099 Fax 886 2 2799 3828 Website www liteputer com tw E mail sales liteputer com tw Shanghai Building B5 No 298 Lane 3509 Hongmei S Road Shanghai China 201108 Tel 86 21 5440 8210 Fax 86 21 6497 8079 Website www liteputer com cn E mail sales_china liteputer com tw EPX 410D 420D 430D 810D 820D 830D EUM A 17
10. s zone 5 can be controlled recall scenes by ECP panel configure as zone 5 Figure 1 One EDX EPX device with one ECP scene panel FOX EPX Device Zone 01 FCP Panel Zone 01 FDX Signal EPX 410D 420D 430D 810D 820D 830D EUM A 10 Lite Puter Figure 2 Multiple EDX EPX devices with ECP scene panels FOX EPX Device EDXEPX Device Zone 01 Zone 02 FCP Panel FCP Panel fone 01 Zone 02 DID ILI CA C CA C LL ES CL ES Er EH ILI EDX Signal ECP scene panel 1 controls EDX EPX device 1 ECP scene panel 2 controls EDX EPX device 2 If there are both DMX 512 and EDX signal present DMX 512 signal has the highest priority EPX 410D 420D 430D 810D 820D 830D EUM A 11 Lite Puter A 5I ID CH Each EPX EDX series device must have a ID number When one device s working alone there is no need to adjust the ID number but when several devices working together each device must have a different ID number STEP 1 In the main screen press FCN to enter ID number setting STEP 2 Press A or v to change the ID number Press A twice to change ID number from 001 to 003 STEP 3 Press DMX to save Definition of zone The device must set the zone number before use which consists of two parts one is the zone number and another is the start channel address For example There is 4 EPX 420D 16 channels in total in the first zone the zone number of each device shou
11. ss any scene button 1 6 then the primary scene SC1 6 will be recalled first STEP 1 In the main screen press FUNC three times to enter function setting A FSUF Overlap scene primary and secondary scene function are both off B FSU Overlap scene function is ON C FSGe Primary and secondary scene function is ON EPX 410D 420D 430D 810D 820D 830D EUM A H Lite Puter STEP 2 Press A or v to select from Scene ON OFF or Scene Overlap ON OFF STEP 3 After setting press DMX to save NOTE After initialization the default setting of these two functions is OFF 4 5 Partition Setting Generally all channels on EDX EPX devices can be only set to only 1 zone Please refer 3 2 To make EDX EPX devices more flexible you can assign each channel on EDX EPX devices to different zones by using partition function For example you assign channel 1 2 on EPX 420D to partition 1 and channel 3 4 on EPX 430D to partition 2 There are 2 control panels ECP 106 connected to EPX 420D one is set to zone 1 the other is set to zone 2 If scenes are recalled by ECP 106 of zone 1 only channel 1 2 on EPX 420D will change their dimming levels If scenes are recalled by ECP 106 of zone 2 only channel 3 4 on EPX 420D will change their dimming levels Figure Channel 1 and 2 on EDX EPX device in zone 1 channel 1 and 2 are controlled by ECP panel in zone 1 Channel 3 and 4 on EDX EPX devices in zone 2 channel 3 and 4 are co