1. mains and set it in its lowermost position by pressing the Down button on the Easy Touch panel Press the Wheel button 2 to lower the wheels A AGAUTION Avoid being trapped beneath the pool when operating the lifting lowering system Ensure that there is free access around the pool Mark the pool s position with colored tape on the floor so thath the pool always can be placed at the same spot www fjordblink com 11 Remove the magnetic cover panels to gain access to the support feets Adjust the feets under the pool until there is 5 mm free space under each foot Tighten the counter nut in order to secure the stability of the pool 5 mm Calibrating of the lifting lowering system The pool s lifting lowering system must be calibrated before use to ensure correct functionality Press and hold the Up button and the Down button on the Easy Touch panel simultaneously The control box will emit a series of high pitched beeps Hold the two buttons down until the beeps stop approx 10 seconds Release the buttons Press and hold the Wheel button until the pool is all the way down The system will emit slow beeps while going down and change to fast beeps when fully down Release the button Press the Up button and the pool will raise The system is now ready to use www fjordblink com Outlet hose Remove
2. Medical Birth Pool is designed for delivery maternity wards or units and should be used only by healthy women giving birth naturally Models covered in this manual MILIEU 2014 and COMFORT 2014 The only differences between these two pools are the pool size and the location of their lifting lowering system Copyright Fjordblink ApS This manual contains information protected by copyright law No part of it may be reproduced or transmitted in any form without prior written permission from the copyright holder This manual is subject to change without further notice Version 1 1 03 2015 Original instructions Prepared by Technical Writer Ole Krog krogco dk www fjordblink com Symbols used in this manual The following symbols are used in this manual as well as the associated documentation supplied with the product CAUTION IMPORTANT NOTICE AN AN WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury It may also be used to alert against unsafe practices IMPORTANT indicates important information about handling and use of the product NOTICE is used to address practices not related to personal safety Feet crush hazard Take care to avoid injury to feets when in the vicinity of moving mechanical parts Electricity or potentiall
3. User manual Fjordblink Birth Pool and Water Supply Unit www fjordblink com Content Intended EEN 3 Symbols used in this manual nnn e o ov 4 Le EE 5 Product et EEN 6 Main features cau dees nn en a den ce a rr ewe GE 7 Water Supply Unit 0 u a we a a ne ae ped en Bee ss Ex 8 Easy Touch Panel vss au an nn eee ba bdo oo oe en Ehen 9 POL TO BEE 10 Moving the Birth Pool 2 2 2222er une e ee r rer ss os aa 10 Placing the Birth Pool i 50 5 eons a 00 ocean tod nr oso nern 10 Support feet adjustment s s s s ss oo 11 Calibrating of the lifting lowering system 12 OUNT NOSE 4 0 Ges ec a en an nn EE ZW Een RR eee a 13 Filling with Water 4 0 0 a a She ew chen sea 14 Overflow Sensor EE 14 The lifting lowering system nana aaa aa 15 Cleaning and disinfection LLL aaa te ete ee aa aa 16 DISINTECLION Goo de er arr ee chee ea Oo eee che weh 16 About the overflow sensor 2 cee ce ee ee wee et eee et os nee 18 In case of power failure LL et te ee te ee ee ete eee 19 Technical data lt es s bee ee a esas che eeu ae Gee eae se 5 21 Certifications sn a een a ea eeu nen ea ea eee a ee 22 Disposal and recycling 4 is eee eH we Bebe wb EERE Dee eS ex 23 www fjordblink com Intended use The Fjordblink Medical Birth Pool is a physiotherapeutic and medical relaxation pool for water births and can also be used for comfortable reclining and resting The Fjordblink
4. button in this position Remove the protection lid and turn the shaft at the top of the valve Hold on to the MAN button 20 www fjordblink com Technical data o Dimensions Lummen mocowronrzoa Weisht Weight empty 132 kg weight full 410 kg Capacity Ca 520 litres Ca 310 litres Discharge time 3 4 min 2 2 3 min Height adjustment e Hee Fibre lane tls seek OOOO Supply Unit www fjordblink com 21 Disposable hose Non disposable hose Kromm 38 mm inside Length Material Vulcano PU H 09 Etere Polyurathan Microorganism and hydrolysis resistant Working pressure 10 BAR 90 C Cleaning 40 C to 90 C can also resist 125 C over short time max 25 minutes Approvals FDA approved FDA 21 CFR 177 2600 EU approved 10 2011 EC Certifications FJORDBLINK Medical is certified according to DS EN ISO 13485 2012 Medical Devices AC 2009 Bureau Veritas and the product has been certified according to Directives EU Directive 2006 42 EC Machinery Annex I EMC Directive 2004 108 EC Low Voltage Directive 2006 95 EC Standards EN 61000 4 2 1995 A1 A2 EN 61000 4 3 2006 EN 61000 4 4 2005 EN 61000 4 5 1995 A1 EN 61000 4 6 1996 A1 EN 61000 4 8 1993 A1 EN 61000 4 11 2004 EN 55011 1998 A1 A2 Class B EN 55022 1998 A2 Class B EN 61000 3 2 2000 and EN 61000 3 3 1995 A1 EN 60601 1 1990 A1 1993 A2 1995 A13 1996 Medical electrical equipment Standard EN 60601 1 2
5. he Birth Pool s surface nice and shiny we recommend a regular polish with wax or SPA polish designed for acrylic surfaces IMPORTANT The Easy Touch panel must not be cleaned with alcoholic agents Disinfection The pool must be cleaned prior to disinfection An alcoholic disinfection agent min 80 vol should be used The alcoholic disinfection agent must be thoroughly applied with a disposable cloth Never use stronger solutions e g caustic soda You can also use Actichlor plus as a cleaning agent www fjordblink com Remove the pool s drain plug and clean it The drain plug can be autoclaved Clean the drain using a cleaning brush Put the drain plug back in place in the pool 3 Close the outlet valve Fill water in the bottom of the pool approx 10 cm Add a neutral cleaning agent 5 Use the cleaning agent to clean the sides of the pool using a soft cotton cloth 6 Open the outlet valve to let the water run out Rinse the pool thoroughly once again Disinfect the pool with Actichlor or an alcoholic disinfection agent min 80 vol Apply the liquid agent to pool s surfaces and let them dry If you use Actichlor One Actichlor tablet is dissolved in 1 liter of warm water The dissolution time is 10 15 min You can either use a bucket or 1 liter disposable bottles Remove the outlet hose and mount the outlet plug on the outlet flange If you use a non disposable hose it can be autocla
6. l information m Serial number XXXXXXX XXXXXX XX Item Supply Unit 2014 Voltage 230 V 1 two pole earth wired am Max fuse 10 A IP 55 CINE CE e XXXXXX DE gt A 5 AS e FJORDBLINK Medical ApS 7 OKI Vibelandsvej 8 J b ES DK 3200 Helsinge SAN Tel 45 40 74 05 23 Z A P Z gt J im b I A RI w gt Serial number XXXXXXX XXXXXX XX Item Milieu 2014 PN JP Voltage 230 V Frequency 50 HZ gt Max fuse 10 A Total Watt 690 Watt Poa Ce RZ rd MR SD l XXXXXX Full a H R 0 F w FJORDBLINK Medical ApS e ma sie Vibelandsvej 8 wW 6 BI 1 DK 3200 Helsinge oo es 4 gt e Tel 45 40 74 05 23 This product is CE marked in accordance with the European Medical Device Directive 93 42 EEC including amendments incorporated in Directive 2007 47 EEC It also complies with all relevant requirements in the Council Directive 2006 42 EC of 17 May 2006 on machinery and with Council Directive 2011 65 EC of 8 June 2011 on RoHS A declaration of conformity can be found at www fjordblink com The unit s unique serial number The units name Information about power supply and fuses Manufacturing date Manufacturers name and address www fjordblink com Main features Component Water Supply Unit Quick filler Birth Pool Support with adjustable feets Easy Touch Panel EH www fjo
7. nt on large quantities of sand And sand is also the main constituent of glass and thus also of fibreglass Fibreglass additionally contains polyester which can be used as an energy source in cement production thereby replacing the use of fossil fuels Electronics The electronic components should be collected separately and returned to the designated recycling service www fjordblink com 23 BURZ l Fjordblink Medical ApS Vibelandsvej 8 3200 Helsinge Denmark Tel 45 40 74 05 23 E mail postefjordblink com www fjordblink com FJORDBLINK Birth Pools Designed by midwives For midwifes www fjordblink com
8. owering system The Birth Pool can be adjusted 290 335 mm MILIEU 2014 COMFORT 2014 upwards and downwards to ensure the best working position for the midwife Press and hold the Up button to raise the pool and press and hold the Down button to CAU T O N lower the pool Motion stops when the button is released If the pool is resting on its wheels they will A u BEE GER an ne SEH Avoid being trapped beneath the pool when ensuring that the pool will stand firmly l VE operating the lifting lowering system Low position High position www fjordblink com 15 Cleaning and disinfection CAUTION Always read the material safety data sheet MSDS and supplied instructions for the cleaning or disinfecting agent and comply with instructions for safe use dilution rinsing drying handling and storage of the agent After use the pool must be drained immediately and rinsed with clean water Use the hand shower head on the Supply Unit to carefully clean and rinse the pool Regulate the water with the hand shower tap The pool must be cleaned with a neutral cleaning agent using a soft disposable cotton cloth The water used for cleaning must not be warmer than 55 60 C After cleaning carefully rinse the pool again with clean water Never use scouring cleaner or heavy alkaline cleaners and do not use razor blades or other sharp objects for cleaning To keep t
9. rdblink com Water Supply Unit Front Back PU za LD v N d E CN CF d A s SIb gt gt Mm OF 2 Component w CC o 9 reenen www fjordblink com Easy Touch Panel Component www fjordblink com Prior to use Check that the outlet is closed before filling water into the pool This is indicated by light in the water outlet button on the operating panel on the supply unit Check that the pool is level before activating the lifting lowering system and before filling the pool with water Do not move the pool without using the wheels or by means of other lifting tool Moving the Birth Pool The pool is equipped with wheels that can be activated by pressing the Wheel button on the Easy Touch panel when the pool is at its lowest position When the wheels are down the pool can be moved The wheels will lift automatically when you raise the pool so that it cannot be moved Placing the Birth Pool The Birth Pool should be placed on a stable level surface not more than 20 cm away from the Supply Unit Allow at least 50 cm free space between the pool and walls www fjordblink com Support feet adjustment Connect the pool to the
10. second edition 2002 Medical electrical equipment Electromagnetic compatibility EMC parts of EN 1970 2000 Adjustable beds for disabled persons and EN 60601 2 38 1997 A1 2000 Particular requirements for the safety of electrically operated hospital beds EU Directive 2004 108 EC Electromagnetic Compatibility EU Directive 93 42 EEC Medical Devices Approvals CE marked Class 1 Medical Devices EU Directive 93 42 EEC Protection class www fjordblink com Disposal and recycling The unit contains reusable materials There are no known hazards or risks associated with disposal of the product All components can be discarded after having been cleaned and disinfected When disposing of the product we recommend that it be disassembled and broken down into different waste groups for recycling or combustion The following table provides information on the recycling and handling of the product Recyclable components Steel Steel can be recycled by being melted down and included as a secondary material in the production of new steel Acrylic Acrylic as a plastic is recyclable It is considered a Group 7 recyclable Use plastic sorting and recycling systems where they are locally available otherwise incinerating plastic has the added benefit of generating energy which can be used for for example combined heat and power production Material Fibreglass Fibreglass can be recycled and used in cement production Cement is depende
11. the outlet plug and mount the outlet hose before filling water into the pool Attach the outlet hose between the Birth Pool and the Water Supply Unit The outlet hoses comes in two different versions A disposable hose for single use and a non disposable hose that can be autoclaved The non disposable hose can easily be removed again without the use of tools Just unscrew the two outlet flanges The disposable hose uses a push fit connection on the hose flanges 13 www fjordblink com Filling with water Attach the quick filler to the rim of the pool Open the water filler tap and adjust the water temperature using the mixing tap a Overflow sensor The Birth Pool is equipped with sensors that prevent overflow The sensors maintains the water s level and ensure constant circulation of fresh warm water The overflow sensors will open the outlet valve automatically when the water level reaches the pre chosen maximum When the water level drops to the pre chosen minimum approx 4 centimeters below the maximum the outlet valve will automatically close again If the outlet valve opens before the water level has reached its maximum please see section About the overflow sensor The outlet valve can be controlled manually by pressing the outlet button amp on the supply unit Light in the outlet button indicates that the outlet valve is closed www fjordblink com The lifting l
12. ved Pour the Actichlor solution into the drain so that it fills the pool s drain tubes Let the solution remain in the tubes until the pool is prepared for the next user www fjordblink com 17 About the overflow sensor The birth pool s overflow sensor is placed behind the left side panel 8 cm from the top rim of the pool The overflow sensor has a 5 seconds delay so that it doesn t react on random movement like waves and persons that are passing by or touching the pool However if you sit leaning against the side where the sensor sits or put your hand or foot exactly in front of the sensor the outlet valve may open unintentionally If this should happen simply sit in a different way or remove your hand or foot from the sensor area www fjordblink com In case of power failure If the power fails while the pool is filled with water it must be drained manually Always disconnect the power A before removing the pool s side panels o Unplug the power connector from the Supply Unit before touching the outlet valve under the pool Remove one of the side panels on the pool by pulling carefully down at the end of the pool The panel is attached to the pool frame with small springs Loosen the springs carefully 19 www fjordblink com Set the valve on manual MAN by turning the button on the valve Hold the
13. y dangerous voltage www fjordblink com Safety e Read and understand the manual completely before use Keep the manual close to the unit e Comply with this manual to avoid accidents involving serious personal injury e Never use or handle this product in other ways than are specified in this manual as this can put your safety at risk and cause damage to the product e Make sure that everyone who is to install or use the product and its systems has the neces sary information and access to this manual CAUTION e Please comply with these instructions to avoid the product becoming damaged or de stroyed e Do not perform repairs disassembly or assembly operations extensions re adjustments or modifications to this product These must be carried out by Fjordblink or persons autho rized by Fjordblink only e Never use the product if it is defective or damaged Do not use a defective product before it has been repaired NOTICE e The information in this manual is based on correct fitting and installation of the product in accordance with our Assembly instruction e Fjordblink cannot be held liable if the product is used in any way which differs from that described in this guide e Fjordblink reserves the right to amend this manual without prior notice www fjordblink com Product labels The product labels are placed on the back of the Water Supply Unit and on the lower part of the Birth Pool CE Additiona