Home
PowerLog 6s User Manual
Contents
1. U Computer 4 atl Multifunctional Monitor amp Logger Powerlog 6S Program flow chart Logo Screen Inf Screen TY PERRO eee eer LOGSUERAT ENIS S N XXXXXXXXXX PowerLog PowerLog6os 4 Data Log o is shown in the upper right POWER ON EM Vor X X X www hillrc com 1988Kb 16h 34 Logs OFF corner blinkingly e Transfer data to USB port e Save data to the appointed Log File lt HOLD gt lt HOLD gt gt 3 Seconds gt 3 Seconds Monitor Watt monitor Cells monitor 003015mAh 20m 10 CELLS MODE Differencemy OdAuto Differenc OEach Voltage 10 50A 2 4 O87VEh4 162V NEA Ot lt MENU gt KARA a gt 3 Seconds Tachometer monitor TACHOMETER TORIC lt A gt V gt gt 3 Seconds RPN 1200 27 1025 8 30 7 00000297 2D6 Mae Zi MO Ie 3255 00000297d187 5995 0 19000us Max QO Lado ULLQNULL NULL IMM lt not used gt econas PWM monitor TEMP SENSOR LIST Note When you turn off the PowerLog6S it will remember the current screen and start from that screen when next turned on again lt TYPE gt lt MENU gt amp gt 3 Seconds gt 3 Seconds lt MENU gt 3 Select Main Menu SE gt 3 Seconds Details in next page Select Type Q ALARM SETTING Cells Voltag q CELLS VOLT ALARM MAX S SA
2. SY o TEM SETTING Temp Unit Ry Beep Tone LCD Screen RECORD INTERVAL Alarm Setting 0 25 3600Sec Rec Interval 2 SEC Start o Power Save OFahrenheit F BEEP TONE Mikey Tone WiHint Tone MlAlarm Tone START SETTING ViStart music Be Logo Screen MiInf Screen POWER SAVE SET ONot Save _ OBacklight OFF OSleep Mode Brightness Contrast ALARM SETTING Va Signal Outpu Activation TEMPERATURE UNIT Celsius C im D means if no operation on the button for 3 minutes the system will return to monitor screen automatically PWM ADJ RANGE SER 10 0 us MIN LUV URE MAX SEAU OMIE PWM AUTO SPEED Step Interval 5 0 ms PWM SIGNAL LEVEL High Level ly OLow Level ALARM OUTPUT Toggle NO By OToggle NC OHold NO OHold NC ALARM ACTIVATION MDelay Time EA MLogging MiPass Through Fy Multifunctional Monitor amp Logger Powerlog 6S Menu Operation 1 Select the menu items by lt A gt lt W gt buttons the selected item will be shown in white 2 Press lt gt to enter the submenu and hold lt gt for more than 3 seconds it will return to the superior menu Symbol Meanings total voltage of the pack n 0 6 the cell count the maximum voltage difference between the cells ERNE mmM ss jor the timer ss second mm minute hh hour o L O R Lower MIN limit alarm OVER Over MAX limit alarm DIFF Difference limit alar
3. PowerLog 6s Multifunctional Monitor amp Logger FA Multifunctional Monitor amp Logger Powerlog 6S Thank you for purchasing the PowerLog 6S Please read the User s Manual completely and attentively as it contains lots of specific operations and safety information PowerLog 6S is one compact multifunctional monitoring and logging meter adopting 32 bit ARM processor with 12 bit A D convertor to ensure the accurate measurement Specifications Input voltage range 4 5 60 0VDC Current measurement range 130A 130A continuance 40A 40A Cell voltage range 0 05 28 0VDC External temperature measurement range 55 C 125 C 67 F 257 F Pulse measurement range 10us 999999us Pulse width output range O 20ms 0 5us step Tachometer measurement range 0 99999 RPM Voltage resolution accuracy 0 001V 0 5 Current resolution accuracy 0 01A 5 Current loading of test 12mA Maximum voltage for alarm port SOVDC Current drain for alarm port lt 500mA Log files storage 16Mbit 33 hours 2 seconds logging interval Sample logging time interval 0 25 3600 seconds PC connect USB port Weight 29g Dimensions L X W X D 85X40X13mm 3 34 X1 57 X0 51 Special features PowerLog 6S allows bidirectional current sensing adopting 0 2 MQ current sampling resistor with low insertion loss 1 channel 0 60V voltage measurement 6 channels cells voltage measurement can not only
4. shows Are you sure you want to empty and press lt gt to confirm and press any other button to cancel LogFilel File Transfer File Delete Delete the selected file Press lt gt the screen shows 00100 01230 Sirete 3 i esc Are you sure you want to delete and press lt gt to confirm and Transferred data press any other button to cancel 14 Multifunctional Monitor amp Logger Powerlog 65 e PWM Output Select PWM Output and press lt gt and the screen shows PWM OUTPUT lt A gt or lt W gt to select items press lt gt button to confirm press lt gt Manual DRS for more than 3 seconds to return Auto See details below Setting 1 PWM Output Manual Select Manual press lt gt and the screen shows PWM OUTPUT MANU lt A gt or lt W gt to increase decrease value press lt gt button to 1000 0 confirm press lt gt for more than 3 seconds to return The fourth line displays the value setting range If adjust range see Ae AU details as PWM SETTING gt PWM Adjustable Range Settings 2 PWM Output Auto Select Auto press lt gt and the screen shows PWM OUTPUT AUTO Pulse width increases automatically When reaching the Max value it 1000 0 shifts to the Min value This process goes round and round Press any button to start stop the process of automatic pulse increase The fourth line displays the value setting range If adjust range see details as
5. F Send graph as eMail Google Earth Export KIL FE Language Deutsch w CO 44 Donationware 19 close rs I a 2 Click Device gt Choose device and port SiLog ier YZ 7 0 Mm Corre ak Open port no recording FF capa 2 Open port 7 recording W Temp Internal 20 f Fy Multifunctional Monitor amp Logger Powerlog 6S 3 Choose Junsi PowerLog 6S from the list and then choose the correct communication Port EF n T VST 8 Fie Edt Dawe Graph Andy Took View Hap jac Al SEE Rhames aA We ewok gt PP start recorang hare p o aT y a el Temp Ext E Temp Ext Wam Power og BE F temp ta Type Cala logge FF Fuke Period TEE to Pos Pulse Width EEG FF Cell Ej E Aonais Hui aoid E miimi ti ee ae tol se FH ces Connechon cet Fle Edt Device Graph Anatysis Tocs wiew He tt pauna Soa RER AR E a lt work gt Terre Intareial E Teme Ext I W Temp Ext 2 f Tap Ext 3 ff Pulse Period ff Poe Puss Waihi E cel t W Celli ces W Celi x F ces z z i z lt W cle of gol Fojl Ea zo a Fr Power T amp E EL ind kj 7 5 Start the logging function of PowerLog see P11 or enter the menu of Log Files File Transmit see P14 Refer to the LogView online help for more information about its features and operation Ii
6. is applied with no load attached to the motor Number of Mode0 It works at the 2 wire mode suitable for the KV Modep OPERA OLE SKO aiaia magnet poles measurement of brushless motor 00953 KV value l Mode1 It works at the 3 wire mode suitable for the KV RPM Renem Voltage of motor measurement of both brushed and brushless motors Regarding the specific operations please refer to MAIN MENU gt Motor KV Meter P16 Wire Connection Methods of ModeO and Model as the picture below Brushless motor Brushed motor Battery 4 5 28V RPM senor Hall senor 1 2 3 4 5 6 PIN 7 MODE 1 Notes 1 When measuring KV on the Mode O the throttle settings of ESC needs to be set at the Max value 2 If the tested voltage is lower than 4 5V PowerLog needs auxiliary power supply ia EET e Data Logging When in Monitor status press lt W gt button for 3 seconds after it shows Start logging the will be shown alternatively at the upper right corner of the LCD screen In this status the system will transmit the data to USB port every X seconds this interval time X can be set by user himself details you can see Record Interval Time Settings in P17 and save these data to the current Log file See Log File Management in P14 If Logs OFF the system will not log file Press lt V gt for 3 seconds again the screen will show Stop logging and then exit Alarm
7. 2 seconds logging interval Support upgrading the hardware program by USB port Adopting HID protocol dispense with installing driver from PC plug and play The PowerLog 6S supports the Logview software and can display plot and analyze the data by it See detail information about Logview in the following website http www logview info 2 h F Multifunctional Monitor amp Logger Powerlog 6S Unpack inspection Standard items The following items are included in the package Contact your supplier if any items are missing CW USB5 10mm 12AWG Optional items The following items are not included in the package 3 at Multifunctional Monitor amp Logger Powerlog 6S External controls and connections U 8 2 3 9 10 11 1 Beep 2 Input T plug T1 3 Output T plug T2 4 Tachometer Sensor 5 LCD screen 6 Buttons 7 Pulse I O J1 8 Temperature Sensor Port J2 9 Multiple Voltage Input Port J3 10 Alarm Port 11 USB Port PowerLog 6S Connection Diagram Temperature sensor 2 or 5V Power it Pulse Input PWM Output Measures RPM vv LN r RPM I P BATT t Measures motor KV PACK __ 4 5 60V CDa Brushless Brushed motor DM O POWER 5 charger 654321 S i nn JL N an I oo an OR LOAD ESC oons on i I A I O1 0
8. PWM SETTING gt PWM Adjustable Range Settings 1000 0 2000 Ous 3 PWM Settings Select Setting and press lt gt and the screen shows PWM OUTPUT SET lt A gt or lt W gt to select items press lt gt button to confirm press lt gt Range a for more than 3 seconds to return Auto Speed evel See details below a PWM Adjustable Range Settings Select Range and press lt gt and the screen shows PWM ADJ RANGE Pulse width adjustable range settings STEPA KOORE Setting range a 2000 0 u STEP0 5 10000us MIN 0 20000us MAX 0 20000us b PWM Auto Speed Settings Select Auto Speed and press lt gt and the screen shows PWM AUTO SPEED The interval time settings of pulse width increment in PWM Output Step Interval AUTO mode AVS Setting range 5 0 5000 0ms c PWM Level Settings Select Level and press lt gt and the screen shows PWM SIGNAL LEVEL High Level High Level my user set OLow Level SS Se oo 20ms Low Level A user set 20ms AS Multifunctional Monitor amp Logger Powerlog 6S e Motor KV Meter Select Motor KV Meter press lt gt and the screen shows See SY Press lt A gt for 3 seconds the number of mode begins blinking and then press lt A gt lt W gt to adjust the value Press lt gt to confirm and lt A gt lt V gt return gt 3 Seconds gt 3 Seconds i Vode JETTE number of Press lt W gt for 3 seconds the
9. Remind If PowerLog detect the alarm events See Alarm Parameters Settings in P12 it will remind as below 1 The buzzer beeps every 4 seconds See Beep Tone Settings in P16 Alarm Tone is selected M 2 The corresponding value and alarm remind show alternatively Alarm Remind Information LOW Lower MIN limit alarm OVER Over MAX limit alarm DIFF Difference alarm T OVER Time over alarm 3 ALM port will output the presetting signal ALM port signal information ALM output port signal is open collector signal as showed below Aoun Please pay attention to the port voltage and current limit when you use lt 50V lt 500mA The following are ALM Output typical application VCC VCC Output t ALM ER ALM Level Output Relay Output 11 FA Multifunctional Monitor amp Logger Powerlog 6S Monitor Alarm Settings The system can have 8 sets alarm settings press lt A gt for 3 seconds to enter SELECT TYPE menu SELECT TYPE The item with is the current setting OLio E lt A gt or lt Y gt to select items and press lt gt button to confirm re Defaulted TYPEs are LiPo Lilo LiFe User1 5 LiFe I LiPo Operate the selected type settings a lt A gt or lt W gt to select the items press lt to enter the next step Rename i Alarm amp Trigger See details below e Change Present Alarm Type Select Select Press lt gt then the item will be with and the settings come in
10. and the screen shows CELL VOLT ALARM applies to the cell voltage in the Cells Monitor CELLS VOLT ALARM MAX ep a interface MIN SEO rd Setting range D Ma 0 05v m MAX 0 06v 28 0v MIN 0 05V 27 99V DIFF 0 01 27 95V 12 Multifunctional Monitor amp Logger Powerlog 6S 2 Pack Voltage Alarm Settings Select Pack Voltage press lt gt and the screen shows PACK VOLT ALARM PACK VOLT ALARM applies to the T plug voltage of Watt Monitor AX 60 00V Ww interface MIN HORNET D LFF RSOKN N SS Setting range 0 05V 60 00V MIN 0 00V 59 95V DIFF0 05V 60 00V 3 Monitor Time Over Settings Select Timer Over press lt gt and the screen shows TIME OVER ALARM TIME OVER ALARM applies to the Timer of Watt Monitor interface Minutes 0 99999 When monitor time is over the set value it alarms T OVER 120 M Setting range 0 99999 minutes 4 Current Alarm Settings Select Current press lt gt and the screen shows CURRENT ALARM CURRENT ALARM applies to the Current of Watt Monitor interface MAX RUN 0 C TA Bo le i MAX 129 0A 130 0A MIN 130 0A 129 5A DIFF0 5A 260 0A 5 Power Alarm Settings Select Power press lt e gt and the screen shows POWER ALARM POWER ALARM applies to the Power of Watt Monitor interface MAX ES UN F DRE 156000 og Seting tange MAX 7799W 7800W MIN 7800W 7799Ww DIFF1W 15600W 6 Capacity Alarm Settings Select Capacity press lt gt and
11. measure 1 6S Li NiIMH NiCd Pb battery individual voltage but also measure 6 channels 0 05 28V voltage 4 channels temperature measurement 1 channel internal temperature measurement and 3 channels external temperature measurement Propeller RPM measurement adopting non contact optical sensing user settable blade number PWM signal measurement frequency period pulse width duty cycle Applicable to remote control channel signal measure and monitor PWM output manual and auto mode auto mode is able to break in servos electronic speed controllers R C switches etc Motor KV measurement The 2 wire mode is suitable for the KV measurement of brushless motor while 3 wire mode is suitable for the KV measurement of both brushed and brushless motors Small size with multiple functions backlight 128764 lattices LCD and Buzzer Tone Reminder the interface can be operated smoothly It can be set Cells Voltage Pack Voltage Timer Over Current Power Capacity Temperature RPM Period and Pulse Alarm What s more the extra alarm output can be linkage controlled by the users It has 8 sets default monitor alarm settings which can be selected for different battery packs PowerLog 6S has been 100 calibrated before it enters to the market at the same time it supports the calibration by users themselves The logging interval can be set by users different needs PowerLog 6S has a 16Mbit flash storage which can log offline data in 33 hours
12. number of magnet poles begins Ode giiUDC mY 1 npase magnet poles blinking and then press lt A gt lt Y gt to adjust the value Press lt gt to ORD 00953 KV value confirm and return RPM RPE USS Motor voltage Setting range MODE 0 1 POLES 2 30 Motor voltage 0 05 28V System Settings Select System press lt gt and the screen shows SYSTEM SETTING lt A gt or lt W gt to select items press lt gt button to confirm press lt e gt Temp Unit J for more than 3 seconds to return Beep Tone See details below LCD Screen Alarm Setting Rec Interval Starte Power Save 1 Temperature Unit Settings Select Temp Unit press lt gt and the screen shows TEMPERATURE UNIT lt A gt or lt W gt to select the items press lt e gt button to confirm and the gt item will be with press lt gt for more than 3 seconds to confirm the OFahrenheit F amendment and return Select Celsius C the temperature unit is Celsius C Select Fahrenheit F the temperature unit is Fahrenheit F 2 Beep Tone Settings Select Beep Tone press lt gt and the screen shows BEEP TONE lt A gt or lt W gt to select the items and press lt gt to shift select W L key Tone ES press lt gt for 3 seconds to confirm the amendment and then return Mint Tone Select Key Tone the buttons tone open MAlarm Tone Select Hint Tone the status tone open Select Alarm Tone the
13. to cancel the sensor which becomes lt not used gt when press lt 4 gt it displays 11 on the right side of the item Press lt A gt lt W gt to alter the sequence and press lt gt to save it Temperature sensor adopts DS18B20 Programmable Resolution 1 Wire Digital Thermometer and the details can refer to http www maxim ic com datasheet index mvp id 2812 The connections to PowerLog as the picture Erda sl T Enpe Pe fi i OUT N _ T Fra g a e A BOTTOM VIEW Every DS18B20 has a unique ID number Under the temperature monitor mode when a S N 000002983990 new sensor connects to it the system will check the ID number of the new sensor ftv automatically as picture 00000297d187 lt not used gt ey Alternatively display Find new DS18B20 S N xxxxxxxxxxxx in the first line while from the second line to the fourth line it displays the ID number of the present T1 T3 sensors Press lt A gt lt W gt to choose the needed Tx while press lt gt and a new temperature sensor will be added in the menu Press lt gt for 3 seconds to cancel the addition If there are other new sensors in this circuit the process will continue The temperature of the added temperature sensor will be displayed in the Temperature Monitor Interface 9 Multifunctional Monitor amp Logger Powerlog 6S 4 PWM Monitor Monitor the input pulse signal from J1 The measurement resol
14. Se Lee Wels LiPo gt LiPo Select i OLilo Rename Pack Voltage Fite AlarmkTrigger Timer Over Ose Current OUser2 Power Cisse ss Capacity OUser4 Temperature PACK VOLT ALARM Cliseres RPM MAX MOm be Period MIN O 000OV TA Pulse Digg 60 00V mM MIN RER 00 DIT F FORTS 4 POWER ALARM RPM ALARM PULSE ALARM TIME OVER ALARM AX NL AX BRSRRITO Ra tae Lie MAX B KKENER Minutes 0 99999 IN t UN IN ie RPM MIN iG us 120 M D I FFER ESOO IND 99990 RPMbI DIFFEREN CAPACITY ALARM TEMP ALARM RERIOD ALARM CURRENT ALARM 100 999900mAh AX Bee MAX REEERE MAX EEEO C 999900 M IN O MIN go us MIN BUN en DIFFERE DI FF RRR STOGES Digg 260 0A M Note D means if no operation on the button for 3 minutes the system will return to monitor screen automatically 6 Multifunctional Monitor amp Logger Note Monitor ore Details in previous page lt TYPE gt lt MENU gt D gt 3 Seconds gt 3 Seconds 3 Main Menu MAIN MENU Log Files DK PWM Output Motor KV Meter System Calibration LOG FILE Logs OFF Re OLogFilel LogFilel File Select RS File Transmit File Empty File Delete PWM OUTPUT PWM OUTPUT MANU anual Ry uto 1000 0 Setting 1000 0 2000 Qus CALIBRATION Default o OUser Setting TOLE SK 00953 PWM OUTPUT AUTO 1000 0 1000 0 2000 Qus PMGSY YUV 03V PWM OUTPUT SET Range q Auto Speed Level
15. alarm tone open have a Do every 4 seconds 3 LCD Brightness amp Contrast Settings Select LCD Screen press lt gt and the screen shows lt A gt increase lt W gt decrease and press lt gt to shift Brightness Contrast press lt for 3 seconds to confirm the amendment and then return Contrast n A6 Multifunctional Monitor amp Logger Powerlog 65 4 Alarm Settings Select Alarm setting press lt and the screen shows ALARM SETTING Signal Out puls ctivation ALARM OUTPUT Otowsle NO I OToggle NC OHold NO OHold NC ALARM ACTIVATION MDelay Time BA Logging MPass Through lt A gt or lt W gt to select items press lt e gt button to confirm press lt gt for more than 3 seconds to return See details below lt A gt or lt W gt to select items press lt gt button to confirm and the item will be with press lt gt for more than 3 seconds to confirm the amendment and return When the measured value exceeds the set alarm limit value the alarm triggers sends out signal When the measured value goes back to the normal status if set Toggle the alarm output recovers to normal if set Hold the alarm output remains Toggle NO Toggle mode normal open Toggle NC Toggle mode normal close Hold NO Hold mode normal open Hold NC Hold mode normal close lt A gt or lt W gt to select the items and press lt gt to sh
16. ax Cell Voltage Min Cell Voltage Cell Number 4 nl REM Cell Voltage en SRo B14 O87Veh4 162V T is in front of the cell with Max Cell Voltage while is g 4 120V in front of the cell with Min Cell Voltage lt MENU gt lt A gt lt V gt Setting range gt 3 Seconds gt 3 Seconds V1 V6 0 05 28 00V CELLS MODE Obi fference Ey Difference Displayed voltage CellVn Vn Vn 1 1 lt n lt eae eee 6 under the condition V6 gt V5 gt V4 gt V3 gt V2 gt V1 gt 0 ND Auto Difference 3 gt First sorting by ascending numeric sequence between V3 V1 V6 then has Vai Va6 CellVn Van Van 17 1 lt n lt 6 5 v5 ve Each Voltage Displayed voltage CellVn Vn 1 lt n lt 6 8 Multifunctional Monitor amp Logger Powerlog 65 3 Temperature Monitor TO is constant internal temperature T1 to T3 are external Int Temperature Frota Current Value temperature i Min Value 4 ig 8 3C Setting range Ext1 Temperature Ext2 Temperature Ext3 Temperature oaa Vx Value i KURDERNE Temp Unit TO 20 C 70 C 4 F 158 F T1 T3 55 C 125 C 67 257 F lt MENU gt lt A gt lt V gt gt 3 Seconds gt 3 Seconds Press lt A gt lt W gt for 3 seconds and enter the screen below Line 2 3 4 in the interface correspond to T1 T2 TEMP SENSOR LIST T3 respectively 00000297e20 6 DDA REE al Press lt A gt lt W gt to choose the needed item and then press lt A gt for 3 seconds
17. display Information Screen if you turn on AF oy F Ad Multifunctional Monitor amp Logger PowerLlog 6 7 Power Management Select Power Save press lt e gt and the screen shows lt A gt or lt W gt to select the items press lt gt button to confirm and the POWER SAVE SET Not Save EO item will be with press lt gt for more than 3 seconds to return OLight OFF Not Save it will work as usual OSleep Mode Light Off it will turn off the backlight after minutes not working with any key the time can be set by the users Press any key to return to the normal status Press lt gt to enter to SAVE TIME SET Sleep Mode it will turn to Sleep Mode after minutes not working with any key for more than 1 seconds the time can be set by the users Press any key to return to the normal status Press lt gt to SAVE TIME SET enter to SAVE TIME SET Minutes 1 240 005 lt A gt or lt W gt to increase decrease press lt to confirm amendment and return Press lt gt for 3 seconds to cancel amendment and return Setting range 1 240 Minutes Calibration Settings Select Calibration and press lt gt and the screen shows CALIBRATION Default Calibration Default calibration made by the manufacturer Obdefault RS before delivery OUser Setting User Setting Calibration by users When itis press lt gt to lt gt enter User Calibration menu The curre
18. ift select W L press lt gt for 3 seconds to confirm the amendment and return Delay Time Delay a period of time after powering on and then begins to monitor alarm cases Logging After entering Start logging status it begins to monitor alarm cases Pass Through The measured value is between the normal value range and then it begins to monitor alarm cases For example the normal working current of one machine is 25A set current alarm MIN 20A MAX 30A If powering on PowerLog first and then the machine since C O during this period it will trigger MIN alarm If set Pass Through it will avoid this undesirable alarm 5 Record Interval Time Settings Select Rec Interval press lt gt and the screen shows RECORD INTERVAL 0 25 3600Sec 2 See Interval Time 6 Start up Settings Select Start START SETTING ViStart Music Ee ILOG Screen Inf Screen lt A gt or lt W gt to increase decrease press lt to confirm amendment and return Press lt 4 gt for 3 seconds to cancel amendment and return Setting range 0 25 3600 Seconds press lt gt and the screen shows lt A gt or lt W gt to select the items and press lt gt to shift select W L press lt gt for 3 seconds to confirm the amendment and return Select Start Music there will be a start music if you turn on Select LOG Screen it will display Logo Screen if you turn on Select Inf Screen it will
19. m Button Function PowerLog has 3 buttons Each button owns two functions The first function is to trigger after only one click the second function is to trigger after holding the button for 3 seconds Click 1 Turn up the menu item 2 Increase the value 3 Select the input character Hold for 3 seconds Enter alarm type select menu lt y gt Click 1 Turn down the menu item 2 Decrease the value 3 Delete the character Hold for 3 seconds Trigger Start Stop logging function Hold for 3 seconds Enter system setting menu C TT Hold for 3 seconds 1 Reset timer watt monitor 2 Enter cells mode menu cells monitor 3 Adjust blades temperature monitor 4 Save user calibration interface lt A gt lt V gt t lt e gt Hold for 3 seconds Current zero point calibration watt monitor on watt monitor Interface Note lt A gt lt V gt means pressing lt A gt and lt W gt at the same time Multifunctional Monitor amp Logger Powerlog 6S QUICK START PowerLog Power On When connecting any of the following power sources PowerLog will be triggered ON Connect the USB port of PC Connect power supply 4 5 60V through T plug T1 or T2 Connect J1 J2 with 5V power supply Connect power supply trough Multiple Voltage Input Port J3 PIN1 connect the negative polarity of the power supply PIN2 PIN7 connect with 4 5 28V voltage ol system self check and then shows the SN and version number the displayed informa
20. nt need to be calibrated item begins to blink If the displayed Alar ee a Current CAA Eaa Pls Voltage value is more than the actual value please press lt W gt to decrease Cell3 Voltage SPAR a Cell4 Voltage Q LEV Cell Voltage EROA i sgag Cell2 Voltage the displayed value to the actual value vice versa please press lt A gt Cell5 Voltage 5 PAGE Cel Voltage to increase the displayed value to the actual value Press lt gt and shift to the next item In this way to get all the calibration Press lt A gt and lt W gt for 3 seconds to save the amendment and exit Press lt gt for 3 seconds to cancel the amendment and exit Note If the user calibrates it in a wrong way which damage the battery or cause other serious danger our company will be of no responsibility 1 In order to have more exact actual current and voltage value we suggest using 45 Digit Multimeter The users calibrated value will not affect the value calibrated the manufacturer It can be selected by CALIBRATION User Setting or Default 18 Fy Multifunctional Monitor amp Logger Powerlog 6S PowerLog Firmware Upgrade Steps e Run the program X Upgrader Upgrader exe you can download the Upgrader exe software from the following website http www jun si com UploadFiles Upgrader rar e Connect the PowerLog 6S to the PC using the supplied USB cable choose Device in Device List then select the upg
21. nter the MAIN MENU Monitor status MAIN MENU lt A gt or lt W gt to select items press lt gt button to confirm Press lt gt Log Files S for more than 3 seconds to return PWM Output See details below System Calibration e Log File Management Select Log Files press lt gt and the screen shows LOG FILE The first item is Logs OFF if it is chosen LOG function is close Logs OFF RS OLogFilel Press lt A gt for 3 seconds to create new Log files lt gt gt 3 Sec Log file name input method lt A gt to select characters hold it to trigger continuously lt V gt to E delete the current character lt gt to confirm the selected character lie Name LogFileiff press lt gt for 2 times to confirm the amendment and return press lt gt for 3 seconds to cancel and return FILE Create The operation to the existing files lt A gt or lt W gt to select items press lt gt to have a selected item and OCR ABER LO12307 p Logging number the the item will be withO press lt gt for more than 3 seconds to return Oloeriict ie file contains OLogFilel inf Shs File Select The selected file is the current log file File Transmit Transmit the selected log file to the USB port it can be received by LogView See details in P20 LogFilel File Select RE File Transmit File Empty s File Empty Empty all selected log files Press lt gt the screen File Delete
22. rade file you can download the latest file The progress bar will appear after you click Update FE 3 CO Jonsi Upgrader Verl 5 Copyright C 2010 Jansi T Include COMs Port Updates List iCharger Release Notes Updated iCZ08B_ 313b S01 0 03 01 iC206B 313b S01 0 03 01 ICLOLOB _ 313b S01 0 03 04 CellLagtasi_v207 2009 11 27 Device List Select Update File D PowerLog PowerLog s_ 102 bin Open Download a iCLOLOB Y313b 2010 03 01 iC1068 Y313b 2010 03 01 iC3010B_ 313h 2010 06 17 FowerLog 65 PowerLog s w102 201007116 File Information Sar Save as M Version W102 Type PowerLog Wit PowerLog sVi02 bin Memo 2010 07 16 et Upgrading 19 CA Multifunctional Monitor amp Logger Powerlog 6S Using LogView for PowerLog 6S First our sincere gratitude to the LogView development team http www logview info Communication steps To install LogView run the program X logview LogViewinstaller exe where X is the drive letter designator for you CD ROM drive e Connect the PowerLog 6S to the PC using the supplied USB cable e Start LogView then follow the illustrated instructions below 1 Please choose language first since the default language is German File Edit Device Graph Analysis Tool View Help pen le Save E Save As History d Import Devicefle Export table Export graph
23. the screen shows CAPACITY ALARM applies to the Capacity of Watt Monitor interface CAPACITY ALARM 100 999900mAh 999900 M When measured capacity is over the set value it alarms Setting range 100 999900mAh 7 Temperature Alarm Settings Select Temperature press lt gt and the screen shows TEMP ALARM TEMP ALARM applies to the Temperature of Temperature Monitor MAX 125 0C MW interface MIN 55 0C Ww DIFF BES OT Setting range MAX 54 9C 125C 55C 124 9C 0 1C 180C 8 RPM Alarm Settings Select RPM press lt gt and the screen shows RPM ALARM RPM ALARM applies to the RPM value of Tachometer Monitor MAX 99990 RPMM interface MIN RO RPM MAJA 99990 RPM Setting range MAX 10 99990RMP 0 99980RMP DIFF 10 99990RPM 9 Period Alarm Settings Select Period press lt gt and the screen shows PERIOD ALARM PERIOD ALARM applies to the Period of PWM Monitor interface MAX CASTELL OTe ncaa TI MIN ig us M IBD 999990us Setting range MAX 140 999990us MIN 0 999980us DIFF10 999990us 10 Pulse Alarm Settings Select Pulse press lt gt and the screen shows PULSE ALARM PULSE ALARM applies to the Pulse width of PWM Monitor MAX SSG interface MIN ig us v DIFF ERRRIOTRE Setting range MAX 10 999990us MIN 0 999980us DIFF10 999990us 43 FA Multifunctional Monitor amp Logger Powerlog 6S Parameter Setup Press lt gt for 3 seconds and e
24. tion is as below Asan T ETE SOREN The first line is the current selected Setting Type See Existent Log Files Number details in P11 The second line shows the log file LOLS AT gags Record Interval Time number And the third line is the available record of aoa gegen Free Capacity Free Time capacity and time The last line shows the current log file Current Log File Name name if no files it shows Logs OFF 3 seconds later the system enters voltage monitor status Monitor There are 5 interface choices which can be shifted by lt gt button 1 Watt Monitor Monitor the input voltage and current of Current zero point calibration T plug When there is no current flowing through T Plug if the displayed current is not zero please press Capacity on NE Timer lt A gt lt V gt lt gt for 3 seconds lt A gt lt V gt lt 4 gt means 10 594 Careri pressing lt A gt and lt Y gt lt e gt at the same time Reset Timer Press lt A gt lt V gt for 3 seconds the time on the upper right corner becomes 00m 00 and the capacity on the upper left corner becomes OmAh Setting range T plug Voltage 4 5 60V Current 130A 130A Capacity O 999999mAh Power 800W 7800W T plug Voltage tr UN BASE Power 2 Cells Monitor Monitor the input voltage of Multiple Voltage Input Port J3 Max Voltage Voltage Sum the sum voltage of Cell Voltage 1 6 Voltage Sum ESKE REE g Bi Difference AV M
25. to effect Rename Alarm Type Select Rename press lt gt and the screen shows ET New Name Input Method lt A gt to select characters hold it to trigger rene continuously until you get the character you need the second cycle of New Name 26 characters will be capital letter lt W gt to delete the current character lt gt to confirm the selected character press lt gt for 2 times to confirm the amendment and return press lt gt for 3 seconds to cancel and return Alarm Parameters Settings Select Alarm amp Trigger press lt e gt and the screen shows ALARM SETTING lt A gt or lt W gt to select items press lt gt enter the submenu While Cells Voltag FS press lt gt for 3 seconds to return Pack Voltage See details below Timer Over Current Power Capacity Temperature RPM Period Pulse When setting the alarm items lt A gt or lt W gt to increase decrease value press lt 4 gt and theni will be blinking press lt A gt or lt W gt to chooseM not choose the alarm item and press lt gt again to shift setting items Only when it is M the item and set value will take into effect Press lt gt for 3 seconds to confirm the amendment and return MAX the upper limit value MIN the lower limit value DIFF the max measuring difference fluctuation range measured MAX value measured Min value 1 Individual Cell Voltage Alarm Settings Select Cells Voltage press lt gt
26. ution of PWM is 1us eee Frequency Freq 1 Period A cae Period The smaller the Period the bigger measurement deviation Pulse duty cycle T bh LINSE M Pulse width Pulse duty cycle PR MERNE SE Pulse width of Freq 5 Tachometer Monitor TACHOMETER Press lt A gt lt W gt for 3 seconds the number of propeller RPM 1206 RPM value blades begins blinking and then press lt A gt lt W gt to Max RPM Alax adeh Number of propeller adjust the value Press lt gt to confirm and return blades SPE 23 secon Setting range nomen RPM 0 99999 Blade 1 20 Right measuring methods Tachometer sensor faces directly to the rotary surface and the light source making the distance between 5 to 20cm Light source Note Tachometer sensor is easily interfered by the electronic light source e g fluorescent lamp please keep it far away from these light sources while it is in use PWM Output The regular period of PWM output is 20ms and PWM pulse signal with changeable duty cycle With regard to servo and throttle signal the positive pulse width is altering between 1 to 2ms as picture 20ms Regarding the specific operations please refer to MAIN MENU gt PWM Output P15 10 Multifunctional Monitor amp Logger Powerlog 6S e Motor KV Meter KV as we use it refers to the RPM constant of a motor it is the number of revolutions per minute that the motor will turn when 1V one Volt
Download Pdf Manuals
Related Search
Related Contents
2 - Audio Services Corporation (Canada) Ltd. CN-CVJM-K209 - 500X Microscope User Manual Bluetooth Speaker E-Boda The Beat 200 G-LSQ Product User`s Manual Firmware 5.00 and up Last Update Compact 5 HD Le Micro - Maino Carlo Srl Whirlpool MSB27C2XAM Use & Care Manual Tripp Lite 8-Port KVM Switch, 1U Rack-Mount, On-Screen Display, PS2 Copyright © All rights reserved.
Failed to retrieve file