Home

MASTER USER MANUAL - Intelligent Security & Fire Ltd

image

Contents

1. Backspace delete 010001000000000 Accept text 14 INS141 6 Premier 412 816 832 Master User Manual System Program Menus Programming Users Enter Access code C Then press then CD Programming Menu Enter Code gt 77 Program User Program User 85 Enter User Number Code DD AsmO O O O v Program User BB Enter User Ho 77 Service denen Enter Code C22C25 25025 Press or if code is less than 6 digits Program User 85 Code i Re enter New Code C25 User Options 1 User 5 rtionzil Enter User Number A e ee o 3 oe Use keys CD to select deselect Options Then press or User Options 2 User 5 rtionsz Enter User Number P UNSERES QD Use keys CD to select deselect Options Then press or User Options 3 User 5 OFtions3 Enter User Number gt P SADA s DD e AamO O O O O 6 O O O O med Service O ces Use keys CD to select deselect Options Then press or Return to point A Continues on Next Page Led Key o Off e On Slow Flash Fast Flash User Options 1 C1 Enable for Partition 1 C2 Enable for Partition 2 C3 Enable for Partition 3 Premier 816 832 C4 Enable for Partition 4 Premie
2. Walk Test Test Speakers amp Outputs Send Test Call Enable Remote Engineer Access DOD wee Start Call Back DC 20 Program Time Program Date Program Banner Text LCD only C95C7D Print 100 Events DD Exit Program Mode DD Fire Safety amp Maintenance 21 Fire Safety Fire Alarm Operation 2 21 Household Fire Safety Audit 21 Fire Escape Planning 21 Maintenance u u u u 22 Inr PX M 22 Installation Records 23 Control Panel enne enne 23 ar E EN 23 ANIM OFS cirea euenit reed en E E nave sans 23 DO NOT REMOVE COVER MAINS VOLTAGES INSIDE No user serviceable parts servicing by qualified personnel only INS141 6 Premier 412 816 832 Master User Manual About the Alarm System 1 About the Alarm System Introduction Your alarm system consists of a control panel one or more keypads and various detectors and sensors The control panel will normally be mounted out of sight in a utility room or basement etc The control panel houses the system s electronics and stand by battery There is normally no reason for anyone except an installer or service person to have access to the control panel The remote keypad is used to send commands
3. a Changing between Delayed and Instant Stay Arming and Disarming Partitions Away Arming Partitions Stay Arming Partitions Disarming Partitions Changing to another Partition Bypassing Zones Manually Bypassing Zones Unbypassing Zones sse Group Bypass Quick Bypass and Arm User Functions Menu Reset Alarms nein iei tiia ortae sa enin 11 Last Alarm Log u u u u 11 Service Faults i211 Acknowledging a New Service Fault View Service Faults n 2 11 Anti code Reset 12 Toggle Chime and Off ves Change User Code eene 13 View Log LCD Only 13 Abort Communications 13 System Program Menus Programming Text LCD Programming Users u Program User DD User Options 1 DD User Options 2 DD User Options 3 DD User Text LCD Only DD Program Standard Users C8 gt CS5 gt i System Tests amp Utilities
4. ALARM MANUFACTURER EXCELLENCE IN CUSTOMER THE YEAR 2000 2000 amp 1999 THANK YOU FOR VOTING TEXECOM MASTER USER MANUAL Z Premier 412 4 Premier CI a Premier e P A Security Control Panels with Integrated Communicator Issue 6 Texecom C www texe com Contents Premier 412 816 832 Master User Manual About the Alarm System 3 Introduction u uu UT uuuasssssssssasassas About this Manual Fite Detectlors ueice iret ere eek nea nr sd naa dedos Monitoring Zones and Partitions Access Codes Remote Keypads Keypad Types Keypad B Vio V E F nctioni Keys iicet ici toria Emergency Keys ceesisecee Operating the Alarm System 6 Introduction Uu u aa u s kannte ra pas risen autos ACCESS COGS icti ranae date dta cina Arming amp Disarming the Alarm System Checking if the System is Ready to Arm Away Arming Stay Arming Cancelling the Arming Process Disarming During Entry okt Disarming when not in Entry Disarming after an Auto Stay Arming
5. code number To change your Access code proceed as follows 1 Enter Access code MCD arm VES to Arm 2088883658 o x for Options 2 Enter O O obec Service qne Coge Enter new code DDD 3 If the code is 4 or 5 digits press the G Ge key to accept DIDIT denen Coge i 4 Re enter new code DCC 5 The keypad will sound an acceptance tone if the new Access code was accepted If you hear an error tone low please repeat from step 1 View Log LCD Only The control panel has an Event Log which stores all system activity i e users entering their codes to arm and disarm the system alarm events faults etc Each event is time and date stamped The number of events stored in the control panel is as follows e Premier 412 750 events e Premier 816 750 events e Premier 832 1000 events To view the Event Log proceed as follows 1 Enter Access code DDD VES to Arm for Ortionsz 2 Enter eE Event Type Event Type showing rena Text Alarm Type amp Zone No 3 Bedroom 1 FA PA Aud BZ Alm ena 15 1555612 13 15 56 28 64 I Partitions Time Day Time Day Month T Press to toggle information displayed 4 Press C to scroll up and down through the log Press to when finished Abort Communications This option aborts any communications to the Alarm Receiving Centre gt To Ab
6. 2041830 2047440 and 2089016 INS141 6
7. armed cS If your system is fitted with a Premier RKP8 16 Plus the Instant light will go off Arming and Disarming Partitions This section covers arming and disarming partitions In order to use these procedures the following requirements must be configured e The alarm system must be split into one or more partitions e Your Access code must be assigned to more than one partition e The keypad that you use to operate the alarm system must be assigned to multiple partitions OR your Access code is enabled for Global Access Away Arming Partitions This option allows you to Away arm one or more partitions gt To Away arm selected partitions proceed as follows 1 Enter Access code CCPC a VES to Arm PC WIS for rtions 2 Press VES to Arm ecu C 6 0 ior io O O Service dene Area gt EL lt The Ready light will flash quickly 3 Press D lt to select deselect partitions e g Press to select Partition 2 VES to Arm Area gt 2 lt Aw O IBI C Q amsa Partition 2 is now selected 4 Press Press Please Exit 17 30 21 Z E B4 The Armed light will flash and the exit tone will sound AamO O O O O O O O O Amsa Service O Ready 5 Leave the area being armed when the partition has armed the exit tone will stop The selected partition s is now Away armed ch If the Quick Arm feature is enabled you can omit step 1 from the above
8. even if the user is not assigned to the partition that is in alarm The user cannot disarm or reset the partition if they are not assigned to it Off The user can only silence alarms for partitions that are assigned to their code User Options 3 C85C3 5 User Options 3 can be enabled or disabled for a selected user so that the level of access to the system may be altered The following options are available C15 Allow Engineer Code Programming On The Access code can access User 00 Engineer in the Program New Users menu menu 80 Off The Access code cannot access user 00 in the Program New Users menu C25 Allow NVM Locking On The Access code is allowed to lock unlock the NVM providing Allow Engineer Programming is enabled Once the NVM is locked the Load Defaults jumper pins on the main control panel are disabled thus preventing the panel from being defaulted Off The Access code cannot lock unlock the NVM INS141 6 17 System Program Menus Premier 412 816 832 Master User Manual C35 Allow Engineer Programming On The Access code can access the Engineer programming menus Off The Access code cannot access the Engineer programming menus X45 Allow Test Call Transmission On The Access code can perform a test transmission to the monitoring station menu 92 see page 20 Off The Access code cannot perform a test transmission C55 Allow Alarm Fault Acknowledgement On The Access code can be us
9. normally assigned to the partition that it is going to control keypad can be assigned to more than one partition if required global keypad Keypad Types The following keypad types are available Premier RKP4 The Premier RKP4 is the standard remote keypad for the Premier 412 control panel This remote keypad has 4 zone indicator lights and four status lights Alarm Service Armed and Ready Premier RKP8 The Premier RKP8 has same features as the Premier RKP4 but has 8 zone indicator lights This keypad is normally used on systems that monitor up to 8 zones Premier RKP16 The Premier RKP16 has same features as the Premier RKP4 but has 16 zone indicator lights This keypad is normally used on systems that monitor up to 16 zones Premier RKP8 Plus The Premier RKP8 Plus has all the features of the standard Premier RKP4 plus dedicated indications for Fire Bypass Instant and Stay It also features two programmable zone inputs that can be utilised by your installer for detection devices close to the location of the remote keypad This keypad is normally used on systems that monitor up to 8 zones Premier RKP16 Plus The Premier RKP16 Plus has same features as the Premier RKP8 Plus but has 16 zone indicator lights This keypad is normally used on systems that monitor up to 16 zones Premier LCD The Premier LCD has a standard size 32 character back lit Liquid Crystal Display plus dedicated indications for Bypass Service Rea
10. procedure Stay Arming Partitions This option allows you to Stay arm one or more partitions To Stay Arm selected partitions proceed as follows 1 Enter Access code DDD mm T VES to Arm ee os for rtions 2 Press ens RE YES to Arm Ec a Area okk lt The Ready light will flash quickly 3 Press D to select deselect partitions e g Press C1 to select Partition 1 Ans in mM VES to Arm du dde es Ares gt Lt lt Partition 1 is now selected 4 Press Premier 516 17 30 21 28784 The selected partition s will arm immediately and the Armed light will flash AO O O O O O O O Ready Service 5 The selected partition s is now Stay armed Disarming Partitions This option allows you to disarm one or more partitions To disarm selected partitions proceed as follows 1 Enter Access code DDD Zones AamO O O O O O O O O Anma HEHU for rtionz e M Roady HO to Disarm 2 Press O O HO to Disarm Area gt Service Ready T The Ready light will flash quickly 3 Press CD to select deselect partitions e g Press C2 to select Partition 2 m 6 mm HO to Disarm Bo ee Area gt 2 amp Partition 2 is now selected for disarm 4 Press Press nes oe d Premier 516 17 30 21 28 704 5 The selected partitions are disarmed INS141 6 Premier 412 81
11. which is supplied by their installer or ARC Telephone Line Fault 2 Wire Smoke Alarm Box Tamper amp Auxiliary Input Press to view type lights 1 5 indicate To perform an Anti code Reset proceed as follows 1 Box Tamper 4 Auxiliary Tamper Enter Access code DDD 2 Auxiliary Tamper 5 Bell Tamper oem 3 Auxiliary PA UK Bell Module e 68686 a MERU Por Getions Date or Time Lost Press emC3 gt Zone Tamper Trouble mos eens seo Service O e Quote Code 4855 Enter Rerluj7 7 The keypad will display a randomly generated Press to view zone number mm O Orme Service O denen Keypad Tamper Removed Press D to view keypad number 958866566 deny 4 digit Code Equipment Faults D Q Ge Service O ene Press to view fault type lights 1 8 indicate 1 Output 1 Fault 2 Output 2 Fault 3 Siren Bell Fault 4 2 Wire Smoke Sensor Fault Tel No Contact your ARC Installer to obtain a Anti code Reset number 5 Auxiliary Fuse Failed 6 Battery Fault 7 Service Timer Zone Soak Test Failed e Enter the Anti code Reset number given to you by your ARC Installer DDD 8 Communication Fault If the code is accepted the keypad will sound an acceptance tone and the system will reset and return to the normal disarmed state Service Faults Displayed on LCD Keypads LCD Fault Condition HC Fail AC Fai
12. 3DEF ghl4GHI GD jkISJKL Gs mno7MNO G 2pqrs7PQRS Dtuv8TUV Q 2WXyz9WXYZ D Space 0 Move Left Right Gs Backspace delete Program User The Program User option allows the master user or users with the appropriate access level to assign new users for the alarm system The number of users including the engineer that are available is as follows e Premier 412 32 Users e Premier 816 32 Users e Premier 832 64 Users User 00 is the Engineer and can only be accessed by the engineer code User 01 is the Master User which has a default code of 5678 Neither of these two users can be deleted from the system Each user is assigned the following attributes e Access Code This is a unique 4 5 or 6 digit code that is assigned to the user The system will allow a mixture of different length Access codes The Access code must be entered at a keypad before the user can operate the alarm system e User Options 1 See User Options 1 on page 17 for details e User Options 2 See User Options 2 on page 17 for details e User Options 3 See User Options 3 on page 17 for details e User Text LCD Only See User Text on page 18 for details 16 INS141 6 Premier 412 816 832 Master User Manual System Program Menus User Options 1 a User Options 1 can be enabled or disabled for a selected user so that the level of access to the system may be altered The following options are available C15 Enab
13. 6 832 Master User Manual Operating the Alarm System Changing to another Partition Normally the remote keypad that you use will be assigned to a particular partition and therefore the zone and status lights will indicate information relevant to the assigned partition However you can temporarily switch the remote keypad to a different partition so that the zone and status lights indicate the information relevant to the partition that you have selected Whilst in this mode you can also use your Access code to arm disarm the partition you have selected providing you have access to the selected partition In order to use the cross partitioning feature it is recommend that the system is configured as follows e Cross partitioning must be enabled e The user must be assigned to multiple partitions e The user should be set for Local Partition Access Only see page 18 e The remote keypads should only be assigned to a single partition To change to another partition proceed as follows 1 Press HREH BRMED gt nes 17 35 34 28 84 Enter partition C15 C45 e g Press to select Partition 2 emet Premier 816 70505055 17155 38 28704 The remote keypad will now indicate information relevant to the selected partition mmo onm N pA After changing to the selected partition the remote keypad will only remain in the selected partition for 10 seconds after the last ke
14. 8704 3 entry tone will stop and the Armed light will turn off The alarm system is now disarmed nore lf a valid Access code is not entered before the end of the entry delay an alarm will occur Disarming when not in Entry To disarm the alarm system when not in entry proceed as follows 1 Enter Access code MCD for rtions EBEN HO to Disarm 2 Press Geen Press Premier 816 209860956 17 38 21 28 84 The Armed light will turn off The alarm system is now disarmed wor lf the system only has one partition you will not have to perform step 2 If the Quick Disarm feature is enabled and the system is Stay armed you can omit step 1 from the above procedure Disarming after an Alarm To disarm the alarm system after an alarm proceed as follows 1 Enter Access code COCO Master Bedroom INESSE Zone B5 Active Master Bedroom 2 The system is disarmed and the keypads display the source of the alarm Seo somo Amid Service O Ready The system must now be reset before you can arm again see page 11 for details on resetting alarms Auto Stay Arming If your installer has enabled the Auto Stay feature the system will automatically Stay arm if the entry exit zone front door is not activated whilst attempting to Away arm the system To auto Stay arm your alarm system proceed as follows 1 Enter Access code DDD VES to Arn for rti
15. a wet cloth Light dusting with a slightly moistened cloth should remove normal accumulations of dust 2 The battery test is designed to determine battery condition We recommend however that the stand by batteries are replaced every five years 3 For other system devices such as smoke detectors passive infrared ultrasonic or microwave motion detectors or glass break detectors consult the respective manufacturer s literature for testing and maintenance Glossary Glossary of terms used in this manual Access Code A four five or six digit code that is used to operate the alarm system Alarm Receiving Centre A remote location where alarm status data is received via the telephone line from the control panel Bypass A feature that allows the user to exclude selected zones from being monitored by the alarm system Chime A feature that allows the keypads and internal sounder to generate a ding dong sound whenever the selected zones are violated Duress Code A special type of Access code that reports a signal to the alarm receiving centre that indicates the system is being operated under duress Forced Armable An option that can be selected on a zone by zone basis that will allow the system to be armed even if the selected zone is violated Group Bypass A feature that allows the user to bypass a group of zones in one go Partition One or more zones that make up an individual area This area can independently b
16. d disarm the system After the Access code has been used to disarm the system it is automatically deleted Off The Access code behaves normally C25 Time Lock Code with Control Timer 1 On When Control Timer 1 is on the Access code will not be accepted by the system When Control Timer 1 is off the Access code will be accepted by the system Off The Access code will be accepted at all times C35 Enable Open Reporting On The system will report an Open condition to the alarm receiving centre when the Access code is used to disarm one or more partitions Off The system will not report an Open status nore panel will always send an open signal after an alarm even if this option is disabled X45 Enable Close Reporting On The system will report a Close condition to the monitoring station when the Access code is used to arm one or more partitions Off The system will not report a Close condition C55 Enable User as Duress Code On The Access code will report a Duress condition to the monitoring station when the Access code is used Off The Access code behaves normally C65 Activate Door Strike Output On When a user Access code is entered the output type Door Strike is activated for 2 seconds Off The user Access code will not activate the Door Strike output CD Allow Global Bell Sounder Silence On This option allows users to silence the bell and internal sounder for any partition
17. dy Armed and Power It also features two programmable zone inputs that can be utilised by your installer for detection devices close to the location of the remote keypad This keypad is normally used on systems that monitor up to 32 zones Premier LCDL The Premier LCDL has the same features as the Premier LCD but has a large size 32 character back lit Liquid Crystal Display This keypad is normally used on systems that monitor up to 32 zones Premier LCDP As Premier LCD with a built in proximity tag reader Premier LCDLP As Premier LCDL with a built in proximity tag reader Keypad Layouts L Zones Alarm O Armed Service O O O O O O O OReady 9 10 4 42 43 14 45 46 4 1 2 6 5 ER STAY 4 5 6 MENU 6 DISARM 7 8 9 0 AREA Premier RKP4 8 16 3 4 5 11 12 13 gt 4 m Service 2 8 gt 222 lt gt aA Lous Yes OD MD Caen Md Premier LCD LCDL LCDP LCDLP INS141 6 Premier 412 816 832 Master User Manual About the Alarm System Alarm Light If an alarm has occurred whilst the partition system was armed the Alarm light will illuminate The alarm partition system cannot be Armed until a standing Ala
18. e armed and disarmed from other partitions Service A condition that will indicate that a problem has occurred with the alarm system or with one of its detection devices Zone zone is an area of protection that has one or more detection sensors connected to it motion detectors glass break detectors door contacts or shock sensors 22 INS141 6 Premier 412 816 832 Master User Manual Installation Records 6 Installation Records Control Panel Model Premier 412 Premier 816 L1 Premier 832 Location Keypads Police Medical PA Quick Quick Location Partitions 4 amp 6 7 amp 9 Silent Disarm Bypass Timers Partition 1 Partition 2 Partition 3 Partition 4 Exit Time Entry Delay 1 Time Entry Delay 2 Time Alarm Delay Time Bell Delay Time Bell Duration Time Engineer Master INS141 6 23 Zones Location _ Partitions Location Partitions 2 3 4 5 6 7 8 9 B Bypass C Chime Installation Company Address Telephone Fax Email Alarm Receiving Centre Account No Telephone Email Texecom www texe com Texecom Ltd 2000 2003 Premier Endstation and Keypads are protected by UK and International Registered Design Registered Design Numbers
19. eady bypassed e 24 hour zones cannot be unbypassed if they are still violated e lf your installer has enabled the Reinstate Bypassed Zones on Disarm option all zones will automatically be unbypassed each time the system is disarmed INS141 6 Operating the Alarm System Premier 412 816 832 Master User Manual Group Bypass The Group Bypass feature allows you to bypass a predefined group of zones The alarm system has up to four groups To bypass a group of zones proceed as follows 1 Enter Access code DDD T fea VES to Arm for Ortions 2 Enter bypass group CD followed by Tu P Burass Zone B s A IS zone 05 Burazzed Bypass Zone BB 04 Burazzed The keypad will display the bypassed zones 3 If required zones can be added or removed from the group by entering the required zone number DO e g Enter OD to add Zone 5 Burazs Zone B Zone 83 Burazzed Burass Zone B Zone B4 Burazzed Burass Zone 85 Zone B5 Burazzed 4 The selected zone is now bypassed Repeat step 3 to bypass additional zones 5 Once the selected zones have been bypassed press to Away arm to Stay arm to return to the normal disarmed state Nore If the Quick Bypass feature is enabled you can omit step 1 from the above procedure When one or more zones are bypassed the Ready light will flash and if the system is fitted with a Premier RKP8 16 Plus or LCD remote keypad then the Bypass lig
20. ed for either audible or silent operation for each keypad Emergency commands are detailed on the inside flap label of each remote keypad INS141 6 Operating the Alarm System Premier 412 816 832 Master User Manual 2 Operating the Alarm System Introduction Before attempting to operate the alarm system ensure you have familiarised yourself with all the arming and disarming methods covered in this section Access Codes e fyou make a mistake whilst entering your Access code simply enter the correct Access code Arming amp Disarming the Alarm System Checking if the System is Ready to Arm To help prevent faults during arming a Ready light has been provided on each keypad The Ready light works as follows e Ifthe Ready light is on steady then the alarm system is ready to be armed e Ifthe Ready light is flashing then the alarm system has bypassed zones and or Force Armable zones that are violated check these zones before proceeding e If the Ready light is off then one or more zones are violated either secure or bypass these zones before proceeding The keypads will display the zones that are violated Zone 81 Active Front Door Zone 84 Active Patio Doors Active zones are scrolled in sequence on LCD keypads OO 0066665 or service Ready Active zones are indicated by the relevant zone lights on LED Keypads pA If any unbypassed zones that are not enabled for Force Arming are vi
21. ed to acknowledge and reset alarms and service faults A user with this option can disarm the system after an alarm even if the user does not have the Allow Disarming option Off The Access code cannot be used to acknowledge and reset alarms and service faults C65 Allow User Programming On The Access code can access the user program menus menu 90 98 Off The Access code cannot access the user program menus C75 Allow User Code Programming On The Access code can access users 01 to 31 in the User programming menus menus 80 85 Off The Access code cannot access user 01 to 31 in the User programming menus Local Partition Access Only On The Access code can only be used to arm and disarm the partitions that are assigned to the remote keypad For example if the user is assigned to all four partitions and they use a remote keypad that is only assigned to Partition 1 they will only be permitted to arm and disarm Partition 1 at that particular remote keypad Off The Access code can be used at any remote keypad Global Access User Text LCD Only CCD If the system is fitted with a LCD remote keypad you can assign up to 8 characters of text to each user This text is used when viewing the system Event Log see page 13 User text is programmed in a similar way to mobile phones Characters are selected by pressing the corresponding key the appropriate number of times to select a character on the same key press lt t
22. er the Time in 24hr format e g 6 30pm 1830 CHOCHOCNDCMD i Ready Program Date Program Date gt 28 84 81 DDAD ADA format Enter the Date ina e g 28 April 2001 280401 Service O 9 Ready Continues on Next Page Fast Flash Top line scrolls active zones Bottom line scrolls tested zones Zone light flashing zone active Zone light on zone tested System Tests CD Test Speakers C2 Test Bells C3 Test Strobes Test Outputs Test LCD Display INS141 6 19 System Program Menus Premier 412 816 832 Master User Manual From Previous Page Print 100 Events Walk Test DOD The Walk Test feature can only be performed when the partition is disarmed 24 hour zones except Fire Tamper and Trouble are disabled during Zone Test allowing Audible PA buttons Silent PA buttons etc to be tested Test Speakers amp Outputs DD This menu options allows you to perform the following tests CD Test Speakers C2 Test Bells C3 Test Strobes C4 Test System Outputs ex When performing the Test System Outputs option only outputs programmed by your installer will be activated during this test Send Test Call DD This menu options allows you to send a test call transmission to your Alarm Receiving Centre pA If the test call is unsuccessful the keypad will sound an error tone Enable Remote Engineer Access LDD Your a
23. ey is used when away arming the system or partition The Stay key is used when Stay arming the system or partition 00000 The Disarm key is used when disarming the system or partition 9 The Area key is normally used when arming and disarming a particular partition When the Area key is pressed on its own the keypad will indicate the armed status of all partitions The Area key can also be used to temporarily switch the keypad to a different partition see page 9 The Chime key is used to enable disable the chime feature see page 12 The Reset key is used to reset the system after an alarm or service fault condition see page 11 The Yes key is used to arm the system and to select menu options CR NOTE 000 The No key is used when disarming the system or partition When a keypad is in use other keypads will be locked out except for emergency functions The lock out will persist 4 seconds after the last key is pressed Information tones will be limited to the keypad in use Emergency Keys In case of emergency the alarm system can provide three immediate emergency alarms by pressing and holding two specific keys for three seconds Emergency Alarm Press Keys D amp D C45 amp C65 NOTE DED The emergency keys can be individually enabled or disabled for each keypad on your alarm system by the installer The Panic alarm can be individually programm
24. ht will also illuminate Quick Bypass and Arm The Quick Bypass and Arm feature allows you to bypass a predefined group of zones and Away or Stay arm the system The alarm system has up to four groups To Quick Bypass a group of zones and Away arm proceed as follows 1 Enter bypass group C1 gt cus T ee Premier 816 19 38 56 28704 2 pa T Tu Pleaze Exit o G t 19 30 56 28204 The Armed and Ready lights will flash and the exit tone will sound 3 When the exit tone stops the system is Away armed with the selected group of zones bypassed To Quick Bypass a group of zones and Stay arm proceed as follows 1 Enter bypass group D gt Pam d md Premier 816 19 30 56 28704 2 FE Premier 516 19 38 56 28704 alarm system will arm immediately the and Ready lights will flash 3 The system is Stay armed with the selected group of zones bypassed D The Quick Arm feature must be enabled to use this feature 10 INS141 6 Premier 412 816 832 Master User Manual User Functions Menu 3 User Functions Menu This section covers the more advanced functions that selected users can perform with the alarm system The following functions are available Reset Alarms This function is used to reset any standing alarms and service faults It is also used to reset detectors with a latched alarm indicati
25. ibed above If there is no smoke the system will return to normal operation To reset smoke detectors proceed as follows 1 Enter your Access code DODAO 2 Press the key followed by the C0 key If your system is fitted with either a Premier RKP8 16 Plus or LCD remote keypad then press the key 3 The keypad will bleep and the alarm system will reset all latching detectors wore f you suspect that a fire alarm has transmitted and that there is no fire condition call the alarm receiving centre to avoid an unnecessary response If a fire condition is apparent follow your evacuation plan immediately If the alarm sounds at night evacuate immediately The description above may not be applicable depending on how your installer has programmed the fire alarm operations on your system Ask your installer for more information regarding your system s operation Household Fire Safety Audit Most fires occur in the home To minimise the risk of fire it is recommended that a household safety audit is conducted and a fire escape plan is developed e Are all electrical appliances and outlets in a safe condition Check for frayed cords overloaded lighting circuits etc If you are uncertain about the condition of your electrical appliances or household service have a professional evaluate these units e Are all flammable liquids stored safely in closed containers in a well ventilated cool area Cleaning with flammable liquids sh
26. l Line Fault Telephone Line Fault 2 Wire Smoke Alarm Smoke Alarm 217 Toggle Chime On and Off Box Hux Tamper Box Tamper When zone is enabled for Chime the keypad will generate a Chime tone every time the zone is violated This function allows you to turn the Chime feature on and off Aux Tamper Auxiliary Tamper Aux Input Auxilires Tamper Auxiliary Tamper UK Bell Module Bell Tamper UK Bell Module Auxiliary PA Aux Input Bell Tamper Aux PA Alarm To toggle Chime on and off proceed as follows Enter Access code DDD pes oe VES to Arm oe 5668 Pp MENU for Options Enter 504 Press De 2 Premier 816 NE 17 38 21 28484 If Chime was off it will turn on and the keypad will sound the Chime tone If Chime was on it will turn off and the keypad will sound the acceptance tone DateTime Loss Date or Time Lost Tamper Zone gt Zone Tamper Trouble TamrFer Keyrad gt 1 Quteut 1 Fault Quteut Z Fault Keypad Tamper Removed Output 1 Fault Output 2 Fault Siren Bell Fault 2 Wire Smoke Sensor Fault Fuse Fault Auxiliary Fuse Failed Battery Fault Battery Fault Service Reauired Service Timer Zone Soak Test Failed Coms Failed Communication Fault INS141 6 Premier 412 816 832 Master User Manual User Functions Menu Change User Code All users of the alarm system can change their own Access
27. lank its display after a period of time An Access code may be required to re enable the display Otherwise simply press any key Zone display is always enabled when the alarm system is in alarm Function Keys See Function Keys Fire if the Fire light is on with no zone indicators illuminated then a fire alarm has occurred from one of the 2 wire smoke sensors If there is an accompanied zone indication the fire alarm has occurred from the smoke sensor on the indicated zone Bypass If the Bypass light is on one or more zones have been manually bypassed see Manually Bypassing Zones on page 9 Stay If the Stay light is on the partition system is in the stay armed mode The Armed light will also be flashing Instant If the Instant light is on the partition system is in the stay armed mode and the delayed zones front door etc are instant The Armed light will also be flashing rapidly Power Light The power light is on steady when mains supply is present and flashes when the system is running on battery mains fail LCD Display 16 character Liquid Crystal Display LCD Proximity Tag Reader On Premier LCDP and LCDLP only Function Keys The remote keypad function keys are described as follows 3 lt Function The Bypass key is used for either group or manual bypass of zones see page 9 The Menu key is used to access the more advanced user functions and programming options The Arm k
28. larm system may be configured in such a way that you have to authorise Remote Engineer Access Once authorised your alarm system will allow e Your installer Alarm Receiving Centre to access the alarm system via the remote downloading computer e Your installer engineer to access the control panel programming menus The alarm system will allow access until 12 00am after which both Remote and Engineer Access will be denied Banner Text LCD Only Premier SSP Premier SSP Text Editing Keys I Gabc2ABC Use keys to enter edit text Then press to accept xit Program Mode def3DEF ghl4GHl IKISJKL C65 mno7MNO CD paqrs7PQRS tuvsTUV Dwxyz9wxyZz C0 Space 0 amp Move Left Right Gest Backspace delete Start Call Back DAD This option will cause the control panel to initiate a call back sequence This will allow the remote downloading computer to remotely access the control panel D You should only use this feature when requested by your installer Alarm Receiving Centre If the Call Back is unsuccessful the keypad will sound an error tone Program Time OS The control panel has a real time clock that is used to date and time stamp events that are recorded within the system log The option allows you to set the control panel time Program Date Ow The control panel has a real time clock that is used to date and time stamp events that are recorded within the system log The option allows you to
29. le for Partition 1 On The user can access Partition 1 Off The user cannot access Partition 1 cD Enable for Partition 2 On The user can access Partition 2 Off The user cannot access Partition 2 C35 Enable for Partition 3 Premier 816 832 Only On The user can access Partition 3 Off The user cannot access Partition 3 C45 Enable for Partition 4 Premier 816 832 Only On The user can access Partition 4 Off The user cannot access Partition 4 C55 Allow Arming On The user can arm the partitions they have been given access to Off The user cannot arm any partitions C65 Allow Bypassing On The user can bypass zones in partitions they have been given access to Off The user cannot bypass zones C75 Allow Disarming On The user can disarm the partitions they have been given access to Off The user cannot disarm any partitions wore Engineer code User 00 can only disarm the system if the system was armed with the Engineer code Allow User Functions On The user can access the following user functions e Reset e View Alarm Log e View Service Faults e Enable Chime e Change Own Code Off The user cannot access the above user functions User Options 2 CCD User Options 2 can be enabled or disabled for a selected user so that the level of access to the system may be altered The following options are available C15 Enable One Time Use Access Code On The Access code can only be used once to arm an
30. ls Partitions Control Panel Zones max Premier 412 Premier 816 Premier 832 Access Codes As a user of the alarm system you will be assigned a 4 5 or 6 digit Access code Access codes are used to arm and disarm the partition s to which they are assigned Some Access codes can perform additional system functions such as programming system options bypassing zones and performing system tests Your Access code may not allow you to access certain system functions For instance if your code is only allowed to arm and disarm Partition 1 you will not be able to arm or disarm other partitions or the entire system Your Access code may also be programmed for Global Access A Global Access code can be used at any keypad and will allow you to arm and disarm any of the partitions assigned to your code Alternatively your code may be programmed for Partition Access A Partition Access code will only allow you to arm and disarm the partitions that are assigned to both the keypad and your code The following table shows the number of users for the Premier 412 816 amp 832 control panels Number of Users Control Panel Premier 412 Premier 816 Premier 832 INS141 6 About the Alarm System Premier 412 816 832 Master User Manual Remote Keypads One or more remote keypads will be installed throughout the protected premises usually one at each entry exit door Each remote keypad is
31. n winter outdoor furniture or equipment should not block exits e Each person should know of a predetermined assembly point where everyone can be accounted for i e across the street or at a neighbour s house Once everyone is out of the building call the Fire Services e good plan emphasises quick escape Do not investigate or attempt to fight the fire and do not gather belongings or pets as this wastes valuable time Once outside do not re enter the house Wait for the Fire Services e Write the fire escape plan down and rehearse it frequently so that should an emergency arise everyone will know what to do Revise the plan as conditions change such as the number of people in the home or if there are changes to the building s construction INS141 6 21 Fire Safety amp Maintenance Premier 412 816 832 Master User Manual e Make sure your fire warning system is operational by conducting weekly tests see Fire Alarm Operation on page 21 If you are unsure about system operation contact your installing dealer e We recommend that you contact your local fire department and request further information on fire safety and escape planning If available have your local fire prevention officer conduct an in house fire safety inspection Maintenance With normal use the system requires minimum maintenance The following points should be observed 1 Do not wash the security control panel or keypads with
32. ne Line Fault can each have a delay programmed The Service light will turn steady yellow immediately on either of these faults but no Service Fault Alarm transmission or audible alarm will occur unless the delay expires pA If your installer has disabled AC fail acknowledgement the Service light will flash rapidly during an AC fail condition The system can be armed without requiring acknowledgement of this fault Acknowledging a New Service Fault New service faults can be acknowledged as follows Enter Access code DDD mmo WES to Hrm i reay HEHU for Ftiorzg Press CCD System Faults Press Menu FReset Line Fault Press Menu Feset The keypad will display all Service Faults robec 8 obo Service Reay Press or to acknowledge the fault and return to the normal disarmed state View Service Faults Standing faults can be viewed as follows 1 Press the key followed by the C2 key 2 The keypad will display any Service Faults see tables on next page 3 completion press the key INS141 6 11 User Functions Menu Premier 412 816 832 Master User Manual Service Faults Displayed on LED Keypads Anti code Reset pauicondition This feature is normally used in the UK where users are not AC Fail permitted to reset the panel following a communicated alarm However the user can reset the panel after entering a unique remote reset number
33. o move the cursor along For details on entering text see page 14 Program Standard Users DIED This menu option allows you to add Standard users to the system The user will automatically be assigned the following options User Options 1 Partition 1 Access Allow Arming Allow Bypassing Allow Disarming Allow User Functions User Options 2 Enable Open Reporting Enable Close Reporting Allow Global Bell Sounder Silence User Options 3 Allow Alarm Fault Acknowledgement 18 INS141 6 Premier 412 816 832 Master User Manual System Program Menus System Tests amp Utilities Enter Access code lt gt Then press then CD Programming Menu Enter Code gt 77 Q 6 Om Ready Service O Walk Test Ho Zones Tested Walk Test DWD Activate Zones HOO service O 9 Ready Service Ready Led Key Off On Slow Flash Zone Bl Active 4 l gt Zone 81 Tested OOOO Press C0 to clear tested zones from display Test Speakers amp Outputs Test Syster Enter 1 to 5 Enter Test Number D Test Suster Bells Active gt 200650500 Ready Enable 0805450990 Roaay 2 Press C0 to reset test Send Test Call Remote Engineer Access Start Call Back Program Time Program Time mmo onm Ent
34. olated at the end of the exit delay this is termed an exit error and the alarm system will go into fail set state internal alarm If programmed by the installer the external bell will also sound Enter a valid user Access code to silence this alarm A zone will only be armed when ALL associated partitions are armed but will be disarmed when ANY associated partition is disarmed Away Arming The Away arming mode is normally used when leaving the premises When the system is armed in this mode all detection zones assigned to your partition s will be armed The Ready light must be on steady before the alarm system can be Away armed gt To Away arm the alarm system proceed as follows Enter Access code DDOD ps VES to Arm 200996886 6 om MENU for Getions Press Press i di Please Exit m9 0 8 800 5 8 wam 17 30 21 28704 The Armed light will flash and the exit tone will sound Leave the premises when the system has armed the exit tone will stop The system is now Away armed D If the Quick Arm feature is enabled you can omit step 1 from the above procedure Stay Arming The Stay arming mode is normally used when the premises will be occupied When the system is armed in this mode all Interior detection zones assigned to your partition s will be bypassed Before Stay arming check the following e Secure or bypass any perimeter zones that are violated e Ensure unintentionally perimeter zones a
35. on e g Smoke Detectors To Reset Alarms proceed as follows Enter Access code DDOD ro Dum VES to Arm um e ge 55505 oe for rtions Press e 0D Press Aum O es Premier 516 265896855 17 30 21 28704 The keypad will bleep and the alarm system will reset all latching detectors and attempt to clear any standing Alarms or Service Faults Service O Ready Last Alarm Log The control panel has a memory that stores the zones that caused an alarm when the system was last armed To view the alarm memory proceed as follows Enter Access code DDD is e VES to Arm E THT for Ortions Press Geu C1 gt 209666666 S Last Alarm From Zone Bi Last Alarm From zone B4 The keypad will display the zones that caused an alarm when the system was last armed Service O Ready Press to return to the normal disarmed state Service Faults The response to a Service Fault condition is programmed by the installer but is normally limited to the keypad buzzer To silence the Service Fault alarm enter your Access code A flashing Service light indicates a new fault condition The alarm system cannot be armed whilst a new fault exists The Service light will remain flashing until the new fault is acknowledged after which it will revert to a steady yellow and the alarm system can be armed The Service light will remain steady until all faults have been cleared AC Fail and Telepho
36. onz 2 Press m i Please Exit 17 30 21 28 84 light will flash the exit tone will sound 3 Do NOT leave the premises during the exit delay At the end of the exit delay the alarm system will Stay arm Changing between Delayed and Instant Stay When Stay arming the system the delayed zones front door etc are normally delayed i e when a delayed zone is violated it will start the entry delay timer However it is possible to change the delayed zones to instant when the system is in a Stay armed mode If a delayed zone is violated when the system is in the Instant Stay mode the system will generate an alarm immediately To change from Delayed Stay to Instant Stay proceed as follows 1 Ensure that the system is Stay armed Press and hold the key until you hear the a confirmation tone IMSTAHT STAY seves O 1738 21 28704 ioe 3 The Armed light will flash quickly The system is Instant Stay armed cS If the system is fitted with a Premier RKP8 16 Plus the Instant light will also illuminate INS141 6 Operating the Alarm System Premier 412 816 832 Master User Manual gt To change from Instant Stay to Delayed Stay proceed as follows 1 Ensure that the system is Instant Stay armed Press and hold the key until you hear the 2 confirmation tone a T um DELAYED STAY 17138 21 8484 3 The Armed light will flash slowly The system is Delayed Stay
37. ort Communications proceed as follows 1 Enter Access code MCC res VES to Arm be mro 85 58 55 MENU for Oetions 2 Enter GC iss Premier S16 10500090500 17 30 21 28704 The keypad will bleep and the alarm system will abort all communications to the Alarm Receiving Centre INS141 6 13 System Program Menus Premier 412 816 832 Master User Manual 4 System Program Menus The Master User and Users with the relevant access level can access the System Program Menus These menus allow the users access to the more advanced features and functions of the alarm system The following programming menus are available Function Programming Users Program User User Options 1 User Options 2 User Options 3 User Text Program Standard Users System Tests and Utilities Walk Test Test Speakers and Outputs Send Test Call Enable Download Access Start Call Back Program Time Program Date Program Banner Text Print 100 Events Exit Program Mode A Menus C85C05 C82C5D are restricted to Access codes enabled for Code Programming Master Users Menus DD OD are restricted to Access codes enabled for User Programming To abort programming at any stage and preserve the original settings press ce The alarm system will automatically exit program mode if no key is pressed for 60 seconds To access the programming menu en
38. ould be avoided e Are fire hazardous materials matches well out of reach of children e Are furnaces and wood burning appliances properly installed clean and in good working order Have a professional evaluate these appliances Fire Escape Planning There is often very little time between the detection of a fire and the time it becomes deadly It is therefore very important that a family escape plan be developed and rehearsed 1 Every family member should participate in developing the escape plan 2 Study the possible escape routes from each location within the house Since many fires occur at night special attention should be given to the escape routes from sleeping quarters 3 Escape from a bedroom must be possible without opening the interior door Consider the following when making your escape plans e sure that all perimeter doors and windows are easily opened Ensure that they are not painted shut and that their locking mechanisms operate smoothly e f opening or using the exit is too difficult for children the elderly or handicapped plans for rescue should be developed This includes making sure that those who are to perform the rescue can promptly hear the fire warning signal e f the exit is above the ground level an approved fire ladder or rope should be provided as well as training in its use e Exits on the ground level should be kept clear Be sure to remove snow from exterior patio doors i
39. r 816 832 C5 Allow Arming C6 Allow Bypassing Allow Disarming Allow User Functions User Options 2 C1 Enable One Time Use Access Code Time Lock Code with Control Timer 1 C3 Enable Open Reporting C4 Enable Close Reporting C5 Enable User as Duress Code C6 Activate Door Strike Output Allow Global Bell Sounder Silence User Options 3 CD Allow Engineer Code Programming C2 Allow NVM Locking C3 Allow Engineer Programming C Allow Test Call Transmission Allow Alarm Fault Acknowledgement C6 Allow User Programming Allow User Code Programming Local Partition Access Only INS141 6 15 System Program Menus Premier 412 816 832 Master User Manual From Previous Page Bf User Text Engineer S User BB Text Enter User Number DD Delete User Enter User Number DD semo k SS M Ready Use to select User s Engineer Press to edit text ser B Text Use keys to enter edit text Then press to accept Program Standard Users Program User B Enter User 2 Program User 85 Code i Ready Enter Code DDD Press or if code is less than 6 digits Program User 85 Code i sx DIDIT W Reasy Re enter New Code 220200200 Program User B Code i DIDI dne Press Text Editing Keys 4 5 2 19 amp G25abc2ABC GD def
40. re bypassed e Ensure no perimeter Force Armable zones are violated unintentionally To Stay arm the alarm system proceed as follows Enter Access code DDD pe YES to Arm 279552090500 MENU for rtions Press rey Premier amp 16 amp 2090509 555 17 30 21 28704 alarm system will immediately the light will flash The system is now Stay armed D If the Quick Arm feature is enabled you can omit step 1 from the above procedure If the system is fitted with a Premier RKP8 16 Plus then the Stay light will also illuminate when the system is Stay armed INS141 6 Premier 412 816 832 Master User Manual Operating the Alarm System Cancelling the Arming Process To cancel the arming process during the exit delay 1 Enter Access code CCC is nor for 209550506 HO to Disarm 2 Press Press o pm Premier 516 17 36 21 28704 Arming has been cancelled the alarm system is now disarmed ch If the system only has one partition you will not have to perform step 2 Disarming During Entry To disarm the alarm system during entry proceed as follows 1 Enter the premises via the designated entry point the entry tone will sound Proceed directly to the remote keypad Enter Your Code BE 30 59 222484 mon i uu oem Service Ready 2 Enter Access code DODO E m Premier 516 705500956 B8 31 12 2
41. rm has been acknowledged reset see Acknowledging an Alarm on page 11 Service Light The Service light will flash when a new fault occurs and will change to on steady when the fault has been acknowledged When the system is free of all faults the Service light will be off The alarm system cannot be armed until the new faults have been acknowledged see Service Faults on page 11 Armed Light The Armed light indicates the armed status of the partition system The Armed light is on when the partitions assigned to the keypad are armed When the Armed light is off the partitions are disarmed The Armed light will flash as follows Partition in Exit Slow flash 1 second on 1 second off Partition is Delayed Stay Armed Slow flash 1 second on 1 second off Partition is Instant Stay Armed Fast flash milliseconds on 200 milliseconds off 200 Ready Light If the Ready light is on the partition system is ready for arming If the Ready light is off one or more zones within the partition system are violated check the relevant zones as indicated on the keypads If the Ready light is flashing one or more zones are bypassed or are violated and force armable Zone Lights The zone lights indicate the status of each alarm zone within the partition When a zone is violated or in trouble the relevant zone light will illuminate When a zone is secure the relevant zone light will be off A keypad can be programmed to b
42. set the date on the control panel Program Banner Text LCD only MD If the system is fitted with a LCD remote keypad you can assign up to 16 characters of text to the Banner Message The Banner Message is displayed on the top line of the LCD display during the normal disarmed state Text is programmed in a similar way to mobile phones Characters are selected by pressing the corresponding key the appropriate number of times to select a character on the same key press C to move the cursor along For details on entering text see page 14 Print 100 Events Oc If your system has a printer connected this menu option allows the last 100 events in the system Event Log to be sent to the printer Exit Program Mode DD Selecting this menu option will log you out of programming mode and return the system to its normal state 20 INS141 6 Premier 412 816 832 Master User Manual Fire Safety amp Maintenance 5 Fire Safety amp Maintenance Fire Safety Fire Alarm Operation Alarm On a fire alarm the bell or siren will pulse ON and OFF If your system is fitted with a Premier RKP8 16 Plus then the Fire light will be illuminated The alarm is also transmitted to the Alarm Receiving Centre if your installer has enabled this feature Silence To silence the bell or siren enter your Access code Resetting Smoke Detectors Once the smoke detector is reset if it still detects smoke the alarm sequence will resound as descr
43. ter your Access code DODD and press followed by C9 Enter Access code Then press Gen then C9 Y Programming Meru Enter Code gt 77 Zone ES Ready light flashes All Zone lights lit and Enter menu command D A programming menu is selected by entering a two digit menu code On completion of each menu option the system reverts to the main programming menu allowing other programming menu options to be accessed To exit the programming menu enter W or press the key the system will revert to normal operation Fragrammin Menu Enter Code gt 77 E c All Zone lights lit and service a a Ready light flashes To exit programming mode enter QCD or press Gem Y Premier 516 1z 45 59 2804 LCD shows banner text and time date All zones clear and Ready light on Programming Text LCD Only Text is programmed in a similar way to mobile phones Characters are selected by pressing the corresponding key the appropriate number of times to select a character on the same key press C to move the cursor along The table below shows the keys to use and the characters that are assigned to them Characters A lt ojan Z c GO O gt gt x Y 2 Custom characters x y 0 Move cursor left and right
44. to the system and to display the current system status via the various coloured lights LED s The keypad also provides audible feedback each time a key is pressed Each keypad will be mounted in convenient locations inside the protected premises near designated points of entry exit Read this manual carefully and have your installer instruct you on your system s operation Become familiar with the features that have been implemented on your system All users of this system should be equally instructed in its use About this Manual This manual is a thorough explanation of all system functions including troubleshooting and programming Access codes in addition to performing basic system functions Most users of the system will not need to know all of this information The section of this manual titled Operating your Alarm System explains general system concepts and instructs the user on how to arm and disarm the system and bypass zones The remaining sections of the manual are reserved for more detailed system information Fire Detection This equipment is capable of monitoring fire detection devices such as smoke detectors and providing a warning alarm if a fire condition is detected Good fire detection depends on having adequate numbers of fire detectors placed in appropriate locations This equipment should be installed in accordance with the relevant local authority fire regulations Carefully review the Fire Escape Planning g
45. uidelines in this manual pA Your installer must enable the fire detection feature of this equipment before it will work Monitoring This system is capable of transmitting alarms troubles and emergency information over telephone lines to an alarm monitoring station If you inadvertently initiate an alarm immediately call the Alarm Receiving Centre ARC to prevent an unnecessary response pA Your installer must enable the monitoring function before it will work Zones and Partitions Your installer has divided the protected premises into zones and partitions A zone is an area of protection that has one or more detection sensors connected to it motion detectors glass break detectors door contacts or shock sensors A single zone might be a room a hallway or a door or window Two or more of these zones will be linked together by the control panel to form a partition A partition is an area of the protected premises A partition can be armed and disarmed independently from other partitions All of the partitions together form the entire alarm system If your alarm system is not divided into partitions then all devices will be assigned to Partition 1 Some zones may belong to more than one partition such as points of entry exit and hallways These are called Global Zones because they are not assigned to a single partition The following table shows the number of zones and partitions for the Premier 412 816 amp 832 control pane
46. y press However if an Access code is entered whilst the remote is in this mode the remote keypad will remain in the selected partition for 1 minute after the last key press Bypassing Zones Manually Bypassing Zones Bypassing a zone prevents it from causing an alarm D After manually bypassing a zone the zone will remain bypassed until the zone is manually unbypassed The Bypass menu will time out if no key is pressed for 60 seconds To manually bypass zones proceed as follows 1 Enter Access code DDOD As pcm VES to Arm 066800666 o i for Options 2 Press Bupass Zone B HOHE BYPASSED The Ready light will flash quickly Enter the zone number DO e g Enter OD to select Zone 2 umo Service O dene Eurazz Zone Bz e Q O 5 Q rz zone BZ Burassed Service O The selected zone is now bypassed Repeat step 3 to bypass additional zones Once the selected zones have been bypassed press D G to Away arm to Stay arm to return to the normal disarmed state worm lf the Quick Bypass feature is enabled you can omit step 1 from the above procedure When one or more zones are bypassed the Ready light will flash and if the system is fitted with a Premier RKP8 16 Plus or LCD remote keypad then the Bypass light will also illuminate Unbypassing Zones To manually unbypass zones perform the manual Bypass procedure on a zone that is alr