1. lt 30 gt 82 108 a w lt 4 Do t Ott VIEW a T oT N 2 Y1 l ot S i i TERMINAL i DAN g g COVER GLAND PLUG 2 FIXING HOLES 8 DIA Dimensions mm Y J y Hed 2 x Fixing holes 14 Dia Installation Recommendations Please refer to our User Manual for mounting and wiring instructions The installation of Talentum flame detectors should be undertaken in accordance with recognised national or international standards and OF codes of practice Specifications and wiring information are provided for information only and are believed to be accurate FFE Ltd assumes no responsibility for their use Data and design are subject to change without notice Installation and wiring instructions are shipped with the products and should always be used for actual installation For more information contact your Sales Representative m www ffeuk com Document Part No 24 0062 02
2. blind m Tunnels m LNG LPG production m High ambient temperature applications m Nuclear power sites m Suitable for indoor and outdoor areas m Unaffected by convection currents draughts or wind Accessories m Proven response to multiple fuel types 07127 Stainless Steel Adjustable Mount 3 6 2545 Stainless Steel Weather Shield 304 Multi spectrum detection j 16091 Portable Flame Detector Tester m Selectable output options m Selectable response speed r m Selectable sensitivity levels m Built in auto and manual test m Low current consumption m Fast response to fire Approvals Visit www ffeuk com for up to date approvals information www ffeuk com Talentum 629 Mechanical Specification talentum Housing Material Housing Colour Dimensions Weight Cable Gland Entries Wiring Electrical Specification Supply Voltage Quiescent Current Alarm Current Power Up Time Test Signal Voltage Relay Outputs Programmable Ratings Current Voltage Power Environmental Operating Temperature Storage Temperature Relative Humidity IP Rating Performance Range Class Class 3 Field of View Spectral Response UV IR ite FFE Limited 9 Hunting Gate Hitchin Hertfordshire SG4 OTJ UK t 44 0 1462 444 740 f 44 0 1462 444 789 e sales ffeuk com w www ffeuk com Die Cast Zinc Alloy ZAI 2 Blue 42 H x 1080M x 82 D mm 2kg 2 x 20mm 0 to 4 0mm 14
3. Flame Detection talentum Talentum 1629 UV IR Flame Detector High Ambient Temperature The Talentum Ultra Violet dual Infra Red UV IR2 Flame Detector is designed to protect areas where open fires may be expected and detects most flames from hydrocarbon fires with 4 3m emissions through to invisible fires such as hydrogen The UV IR Flame Detector is sensitive to flickering low frequency l 5Hz infra red radiation along with ultra violet emitted by flames during combustion This detector has a UV sensor and two IR sensors which respond to different wavelengths of both the ultra violet and the infra red spectrum The signals from these sensors are processed by the detector and checked for characteristics of a flame The simultaneous detection of both the UV and the IR light by the sensors will signal an Applications alarm False alarms from flickering sunlight arc welding and lightning eE E TN Storage tanks are eliminated by a combination of UV and dual IR signal processing techniques m Generators a Engine rooms a Compressor stations m Pharmaceutical production The Talentum UVAR detector has selectable output options of relay seas Military applications m contacts or 4 to 20mA signal as standard Ign voltage equipment Power plants m Marine lindustry Features m Fuel loading racks m Aircraft hangars m Highest immunity to false sources Chemical plants m Petrochemical offshore onshore m Solar
4. to 30Vdc 8mA RL2 energised 4mA current loop RL2 off 3mA RL2 off 28mA RLI amp RL2 energised 20mA current loop RLI amp 2 off 9mA RLI energised 2 seconds max 14 to 30Vdc Normally Open or Normally Closed Latching or Non latching 0A Max 50Vdc Max 30W Max Note Resistive Loads Only 10 C to 85 C 20 C to 65 C 95 Non condensing IP65 0 Im n heptane at 25m O m n heptane at 12m see EN54 10 for sensitivity settings 90 min Cone 185 to 260nm O to 2 7um Formerly known as Fire Fighting Enterprises Ltd Response Characteristics High Sensitivity Fuel Flame Size Distance Average Response m ft m ft time seconds n Heptane 0 3x0 3 I x I 25 82 4 Yellow flame Methylated Spirit 0 5x0 5 1 6 x 1 6 25 82 6 Clear flame Hydrogen O09 10 3 136 1239 8 non visible flame has been tested and approved at Class Field of View 15 i 15 75 75 90 90 0 40m To meet the requirements of EN54 10 clause 5 4 where the ratio of the response points Dmax Dmin should not exceed 41 the horizontal and vertical viewing angles amax should not exceed 30 Flame Detector Mounting Bracket

Download Pdf Manuals

image

Related Search

Related Contents

1 BIJSLUITER VOOR HET PUBLIEK Benaming  ECS H81H3-A3 motherboard  - Hitachi Construction Machinery Europe    Manual de instruçőes  la réadaptation respiratoire et la BPCO une    Samsung ปริ้นเตอร์ เลเซอร์สี SL-C1810W (18 / 18 ppm) คู่มือการใช้งาน  THE WILLIAMSWARN PERSoNAL BREWERy USER MANUAL    

Copyright © All rights reserved.
Failed to retrieve file