Contents
1. COMPENSATION VALUE 1 Press the ON OFF key to turn on the scale 2 Press and hold the UNIT key 3 seconds to enter Gravity Compensation mode the display will show 9 796 or the current value 3 Enter the desired gravity value press the UNIT key to choose number from 0 9 and press HOLD key to move to right digit 4 Press TARE key to confirm the entered gravity and return the scale to the normal operating mode DISPLAY MESSAGES Low free Renee Zero count too low Over Load Zero count too high CARE AND MAINTENANCE The heart of the PS 7 Digital Portion Scale is a precision load cell located in the center of the scale base It will provide accurate operation indefinitely if protected against overload of scale capacity dropping items on scale or other extreme shock DO NOT submerge scale or display in water pour or spray water directly on them DO NOT use acetone thinner or other volatile solvents for cleaning DO NOT expose scale or display to direct sunlight or temperature extremes DO NOT place scale in front of heating cooling vents DO clean scale and display with a damp soft cloth and mild non abrasive detergent DO remove power before cleaning with a damp cloth DO provide clean AC power and adequate protection against lightning damage DO keep surroundings clear to provide clean and adequate air circulation
2. Te VA J NAT VIVI ERDE 2 DETECTO MODEL VET330 DIGITAL VETERINARY SCALE Operation Manual INTRODUCTION Thank you for purchasing our Detecto Model VET330 Digital Veterinary Scale The VET330 is equipped with a rechargeable battery pack that after 14 hours of charging is able to provide approximate 8 hours of continuous use This manual will guide you through setup and operation of your scale Please read it thoroughly before attempting to operate this scale and keep it handy for future reference FCC COMPLIANCE STATEMENT WARNING This equipment generates uses and can radiate radio frequency and if not installed and used in accordance with the instruction manual may cause interference to radio communications lt has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC rules which are designed to provide reasonable protection against such interference when operated in a commercial environment Operation of this equipment in a residential area may cause interference in which case the user will be responsible to take whatever measures necessary to correct the interference You may find the booklet How to Identify and Resolve Radio TV Interference Problems prepared by the Federal Communications Commission helpful It is available from the U S Government Printing Office Washington D C 20402 stock No 001 000 00315 4 All rights reserved Reproduction
3. n for use in most applications In the event that the factory settings do not meet the requirements of your application the following describes the steps to configure the scale TO BEGIN CONFIGURATION 1 Press the ON ZERO OFF key to turn on the scale 2 Press and hold TARE key for 3 seconds When the display shows SEE release the TARE key to enter the Configuration mode The display will change to show i WEIGHING UNITS To select kg kilogram weighing units 1 With the display showing Un t press the HOLD key The display will change to show kg 2 Press the HOLD key to display kg status 3 Press the UNIT key to toggle between Enable display will change to On or Disable display will change to FF 4 Press the HOLD key The display will change to Un st 5 Proceed to AUTOMATIC SHUTOFF To select Ib pounds weighing units 1 With the display showing Un t press the HOLD key and then the UNIT key The display will change to show Ib 2 Press the HOLD key to display Ib status 3 Press the UNIT key to toggle between Enable display will change to Gn or Disable display will change to FF 4 Press the HOLD The display will change to Un vt 5 Proceed to AUTOMATIC SHUTOFF AUTOMATIC SHUTOFF 1 With the display showing Un ot press the press UNIT key The display will change to show AGF EF 2 Press the HOLD key to begin selection of the automatic shut off time in
4. on When the low battery indicator is displayed the operator should plug the power supply into the scale and then into the proper electrical wall outlet The scale will begin charging the battery pack DISPLAY FUNCTIONS The display functions are turned on to indicate that the scale display is in the mode corresponding to the function label or that the status indicated by the label is active O This is turned on when the weight display is stable Capacity 300Ib x 0 2lb 150kg x 100g VET 330 EEE This is turned on when a negative minus weight is displayed O This is turned on when the scale weight has been zeroed This is turned on when the battery pack is near the point it needs to be recharged 4 HOLD This is turned on after pressing the HOLD key kg This is turned on to indicate that the displayed weight is in kilograms Ib This is turned on to indicate that the displayed weight is in pounds KEY FUNCTIONS HOLD 1 Press HOLD key the arrow in the left bottom flashes When the loaded weight is above 3 3 Ib 1 5 kg and stable the arrow stops flashing 2 To disable the hold function press HOLD key again and the arrow disappears 3 Press to confirm the setting for each menu UNIT 1 Press to change the weighing units to the alternate units of measurement if selected during configuration of the scale 2 Press to select menu in the Configuration mode ON ZERO OFF 1 Press and
5. or use without expressed written permission of editorial or pictorial content in any manner is prohibited No patent liability is assumed with respect to the use of the information contained herein While every precaution has been taken in the preparation of this manual the Seller assumes no responsibility for errors or omissions Neither is any liability assumed for damages resulting from use of the information contained herein All instructions and diagrams have been checked for accuracy and ease of application however success and safety in working with tools depend to a great extent upon the individual accuracy skill and caution For this reason the Seller is not able to guarantee the result of any procedure contained herein Nor can they assume responsibility for any damage to property or injury to persons occasioned from the procedures Persons engaging the procedures do so entirely at their own risk Serial Number Date of Purchase Purchased Form RETAIN THIS INFORMATION FOR FUTURE USE TABLE OF CONTENTS INMOGUCUON series niro 1 SPECI Call OMS voce u er 1 InstallatioN Li 2 Display Functions en 3 Key Functions en 4 ODETAUON este as 5 Configuration 0 cece ecee eee eee eeeeae nenn 6 Gravity Compensation 7 Display Message 8 Care and Maintenance 8 SPECIFICATIONS Weight Dis
6. play LCD 7 Digit with decimal 1 0 Characters Dimensions of 10 63 W x 3 54 Dx 1 77 H Display head 270 mm x 90 mm x 45 mm 36 W x 22 Dx 1 977H 900 mm x 550 mm x 50 mm Platform Size Zero Established on power up routine and maintained by auto zero circuitry Built in rechargeable battery pack 7 2VDC 1200mA or 120 VAC 60Hz powering a 15 VDC 300 mA wall plug in UL CUL listed power supply 100 of full scale capacity 40 to 105 F 5 to 35 C Humidity 25 95 RH Capacity and 330lb x 0 2lb 150kg x 100g Division Keys HOLD UNIT ON ZERO OFF TARE Features Low battery indicator Power saving selectable timing auto shut off Weight 52 Lbs 23 5 kg PRECAUTIONS Before using this instrument read this manual and pay special attention to all WARNING symbols A IMPORTANT A ELECTRICAL WARNING INSTALLATION UNPACKING Before beginning installation of your scale make certain the instrument has been received in good condition When removing the scale from its packing inspect it for signs of damage such as exterior dents and scratches Keep the carton and packing material for return shipment if it should become necessary It is the responsibility of the purchaser to file all claims for any damages or loss incurred during transit 1 Remove the scale from the shipping carton and inspect it for any signs of damage 2 Plug in the 15VDC adapter to use the scale and to begin charging
7. release to turn on scale 2 Press and release to turn the scale off 3 Press to reset the display to zero up to 20 of the scale capacity TARE 1 When there is load on the scale press this key to return to zero 2 Press and hold for 3 seconds to enter Configuration mode DO NOT operate the keypad with pointed objects pencils pens etc Damage to keypad resulting from this practice is NOT covered under warranty OPERATION TURN THE SCALE ON Press the ON ZERO OFF key to turn the scale on The scale will display then change to the selected weighing units SELECT THE WEIGHING UNIT Press the UNIT key to alternate between the selected weighing units NOTE Multiple weighing units must be enabled during configuration for this function to be operational WEIGH Place the item to be weighed on the scale platform Wait a moment for the scale display to stabilize then read the weight TO RE ZERO THE WEIGHT DISPLAY To re ZERO the weight display press the ZERO key and continue The scale will re ZERO until 20 of full capacity is reached TO TARE THE WEIGHT DISPLAY To tare the weight display press the TARE key and continue The scale will re TARE until full capacity is reached TO HOLD THE WEIGHT DISPLAY To hold the weight display press the HOLD key The weight will be held until the TARE key or HOLD key is pressed again CONFIGURATION The Scale has been pre configured at the factory and should not require configuratio
8. seconds The display will change to show 28 3 Press the UNIT key to toggle through the selections ict 150 450 300 or UFF 4 When the desired time is displayed press the HOLD key The display will change to show AGF F 5 Proceed to GRAVITY COMPENSATION CONFIGURATION Cont GRAVITY COMPENSATION 1 With the display showing GAF press the press UNIT key 4 times The display will change to show Gr AU 2 Press the HOLD key To Enable the Gravity Compensation mode press the UNIT key The display will change to Gn To Disable the Gravity Compensation mode press the UNIT key The display will change to Ber Press the HOLD key again The display will change to show IG Au Press the UNIT kev The displav will change to show End Press the HOLD key to save the settings and reset the scale OD o g Setup is complete GRAVITY COMPENSATION The Gravity Compensation for your scale has been pre configured at the factory and should not require changing in most locations In the event that the factory settings do not meet the requirements of your location contact the factory for the value for your location With enable from the function setting of the Configuration mode the scale will use the factory set value of 9 796 for the Gravity Compensation If the is disabled the scale will use the value obtained from the factory and entered by the operator for the Gravity Compensation TO CHANGE THE GRAVITY
9. the battery pack Refer to the POWER SUPPLY or BATTERY PACK sections of this manual for more instruction 3 Place the scale on a flat level surface 4 The scale is now ready for use POWER SUPPLY To apply power to the scale using the supplied 15VDC U 300 mA power supply insert the plug from the power supply cable into the power jack on the right side of the indicator and then plug power supply into the proper electrical outlet The scale is now readv for operation BATTERV PACK The scale uses a 7 2VDC 1200 mA built in rechargeable batterv pack The VET330 can operate for approximate 8 hours of continuous use with a fully charged battery pack BATTERV CHARGING To recharge the batterv pack the power supplv must be connected to an AC power outlet and plugged into the scale It will take approximatelv 14 hours to fullv recharge the batterv pack in the scale While the batteries are charging the VET330 can still be operated Note that charging the battery pack for more than 14 hours will not damage it If the power supply is disconnected before the 14 hours the scale will continue to charge the battery pack when the power supply is plugged back in ran Eur Law LOW BATTERY When the battery pack is near the point it needs to be recharged a low battery indicator on the display will turn on If the battery voltage drops too low for accurate weighing the scale will automatically shut off and you will be unable to turn it back
Download Pdf Manuals
Related Search
Related Contents
Rangemaster Professional + 110 Gas Hybrid Solar Inverter TP1501 User Manual Panasonic Cyclonic Bagless Upright Panas。nーc 取扱離主 ADIMASTIC 511 es un sellador Scie à ruban DB-100TM pour la découpe à l`eau ou à sec HANDLEIDING VOOR DE ANGEL PowerAmplifier/AudioRegulator 取扱説明書 A-110S/A-100A Copyright © All rights reserved.