ABB CS31 ARCNET DDE Server

image

Contents

1. can be used on Microsoft Windows NT and 2000 this version of Server uses corresponding SOHARD ARCNET Raw Drivers included in the installation package Also two different Server Distribution Disks are supplied All further information in this manual is same both for 16 bit and 32 bit versions with the exception of several chapters where NT WinRT and PCI ARCNET card specific items are described The Server is primarily intended for use with Wonderware InTouch version 3 01 and later but it may be used by any Microsoft Windows NT or 2000 program that is capable of acting as a DDE FastDDE or SuiteLink Client What is DDE DDE is a complete communication protocol designed by Microsoft to allow applications in the Windows environment to send receive data and instructions to from each other It implements a client server relationship between two concurrently running applications The server application provides the data and accepts requests from any other application interested in its data Requesting applications are called clients Some applications such as InTouch and Excel can simultaneously be both a client and server To obtain data from another application the client program opens a channel to the server application by specifying three things the server application name the topic name and the specific item name For example in the case of Excel the application name is Excel the topic name is the name of the specific spreadsheet
2. Board Name This field is used to enter the ARCNET Board name Board Address This field is used to enter the Board address consistent with the Board Station address selected on the ARCNET adapter card Reply Timeout This field is used to enter the amount of time in milliseconds all Controllers using the selected communication port will be given to reply to commands from the Server Note The default value of 1100 milliseconds should be sufficient for most configurations Board I O Address This field is used to enter the I O base address in hexadecimal of the ARCNET interface The Board I O Address must be consistent with the base address selected on the ARCNET adapter card To select a necessary Board I O Address click on the combo ABB_ARCN DDE Server User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN DDE Server 9 box button and make your choice from list box Care should be taken to select a base address which will not conflict with other devices in the system Note The default Board I O Address is 2E0 Board Memory Segment This field is used to enter the segment address in hexadecimal for the ARCNET chip buffers The Board Memory Segment address must be consistent with the base memory RAM buffer address selected on the ARCNET adapter card To select a necessary Board Memory Segment click on the combo box button and make your choice from list box Note The default Board Memory Segment address is DOOO When all
3. Naming and the Server rejects each write to this topic topics If ShowAllRejectedWrites 1 then information about each rejected write value is displayed by the Server If ShowAllRejectedWrites 0 then the Server rejects each write to the suspended topics without logging any information The default values they are used if WIN INI file does not contain these entries are the following WriteRetryCount 0 ConsecArcnErrorsForLog 1 maxPossiblePackages 8 and ShowAllRejectedWrites 1 Troubleshooting menu The following debugging choices are appended to the Server s System Menu the menu that appears when you click the box in the upper left hand corner of the Server window Suspend Protocol Resume Protocol these choices permit you to turn protocol processing on and off what means that you can suspend access to the PLCs ShowEvents if checked then information about suspended and resumed topics are displayed Show Send if checked then outgoing data is logged in hexadecimal format Show Receive if checked then incoming data is logged in hexadecimal format Show Errors if checked then errors are logged ABB_ARCN DDE Server User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN DDE Server 32 ShowReckPackNumb if checked then number of received ARCNET packages is logged after each request Option is useful only for system configuration not for normal data processing Verbose if checked then all errors are log
4. Notes on Write Command Processing To process more reliable communication a response to write command must be transferred by PLC Application program to the Server after write command is received and successfully processed If the system is configured to process responses to write commands then the Server can recognize whether write command is processed correctly or is it necessary to retry the write command To configure the Server to process response to write command an item WriteRetryCount see chapter Troubleshooting must be included into WIN INI file and non zero value should be assigned to it Value assigned to WriteRetryCount item is number of retries to process write command in case of fault Job Number for Send Package must be used for response to write command and can not be used for response to read commands A response package should contain word value 999 3E7 hex In WW Logger file such response is similar to the following message ABB_ARCN R 02 01 FB 7F 1F 00 E7 03 To create such response package the PLC application program Projekt2 contains the following additional CEs INITV assigning constant value 999 to MW003 15 gt to assign 1 to ASEND enabling bit M003 00 if User First Word in received package indicates data write command gt Z1 gt MW005 00 USER FIRST WORD Z2 MW003 11 const 101 A write Q M003 00 ASEND to store job 31 as data package in storage buffer Write command response data pac
5. Programming System Library of Connection Elements ABB Procontic CS31 The same type variable with group number 0 and channel number 0 is used as a basic variable If the server polls values the 3rd and 4th received words is a bit pattern to identify the data packages which must be send to the Server The bit pattern is used in the CE for bit pattern unpacking in the storage buffer If the server pokes data into the ABB CS31 the 3rd received word is poked value write command is performed only for one Item The 4th received word is 0 Example current line comments starts by AREC JOB 00001 UJOB A62 04 NOO MW003 01 D00 00127 J00 00010 L00 00004 MW00 MW005 00 The first received word JROO A62 05 Parameter JOO Received Job Number This parameter value must be equal to the parameter Job Number for Send Package see Topic Definition dialog box in chapter Topic Definition Command ABB_ARCN DDE Server User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN DDE Server 16 Parameter LOO Number of words of the user data to be received This parameter value must be equal to 4 Received Package in case of read poll Item EW7 15 is shown in the following example Byte No 0 02 Station address of the sender 1 01 Station address of the receiver Continuous pointer address of the first user data byte bis on Unused F DIN identification always 7Fh Low byte of Job Number parameter
6. Server is going to save the current configuration file The path may be changed if necessary Also the path can optionally be recorded in the WIN INI file by selecting the Make this the default configuration file option Doing so will allow the ABB_ARCN Server to find the configuration file automatically each time it is started Configuration File Location When the ABB_ARCN Server starts up it first attempts to locate its configuration file by first checking the WIN INI file for a path which was previously specified If the path is not present in the WIN INI file the Server will assume that the current working directory is to be used To start the Server from an application directory configuration file other than the default configuration file a special switch d is used For example invoke the File Run command from the File Manager or Program Manager and enter the following ABB_ARCN d c directoryname Note There is no limit to the number of configuration files that may be created although each must be in a separate directory ABB_ARCN DDE Server User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN DDE Server 11 Topic Definition Command The user provides each Controller with an arbitrary name which is used as the DDE topic for all references to the Controller The following steps are taken to define the Topics Controllers attached to the network 1 Invoke the Topic Definition command The Topic Definition d
7. communication error message is logged to WW Logger file only if consecutive 2 5 ARCNET communication errors happen Assigning non zero value to ConsecArcnErrorsForLog item in WIN INI file you can protect Logger file from huge amount of random communication error logging Random communication errors may happen but such errors do not affect Server s work therefore it is not reasonable to log all random errors Do not assign values greater then 4 to ConsecArcnErrorsForLog item The maxPossiblePackages entry is used to control number of simultaneously requested data packages If there is no such item in WIN INI file than the Server each time tries to request as many packages as possible It increases amount of communication data but makes WW monitoring slower Using of maxPossiblePackages item allows to access optimal data update rate as well as good monitoring speed To find the best value of maxPossiblePackages item you can check item ShowReckPackNumb in the Server s System Menu see chapter Troubleshooting menu and run the system WW Logger file will show number of received packages after each request Find in Logger file the greatest number of received packages and assign it to maxPossiblePackages item in WIN INI file Restart the Server Do not check ShowReckPackNumb during normal working process The ShowAllRejectedWrites option is useful when communication with a separate topic topics is suspended by Item SUSPEND see chapter Item Point
8. data word of the received package Value is calculated in the ABB_ARCN DDE Server Parameter BASI basic variable The target variable results from the INDX and the basic variables In address calculation the same type variable with group number 0 and channel number 0 MW000 00 is used as a basic variable Use the same CE for word outputs Item Name AW writing also CE for data package send The following group of CE is developed for 12 data packages sending to the ABB_ARCN DDE Server The first one is a CE with Configuration Order Number CON 1 ASEND JOB 00012 ENOO M001 00 CON 1 n00 00001 NOO MW003 02 D00 00127 J00 00010 L00 00001 STOO A62 08 MW00 EW07 15 Parameter ENOO enables the send job Variable in this parameter here M001 00 must be equal to the parameter BIOO in UNPACK block the 3rd word of the Received Package unpacking Parameter J00 Job Number Parameter LOO Number of words of the user data to be sent The represented CE sends 1 data word value of variable EW07 15 CE with Configuration Order Number CON 2 ASEND ENO1 MO001 01 CON 2 n01 00001 NO1 MW003 02 D01 00127 ABB_ARCN DDE Server User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN DDE Server 20 J01 00011 L01 00001 ST01 A62 09 MW01 MW003 00 Parameter EN01 variable in this parameter here M001 01 must be equal to the parameter BIO1 in the UNPACK block the 3rd word of the Received Package unpa
9. the minimum set of software needed to run the ABB_ARCN Server and these infrastructure files must be install prior to executing the ABB ARCN Server 3 The HASP key is needed for full time running of ABB_ARCN Server The HASP Driver setup is performed during the Server setup Without HASP Driver installed and HASP key plugged into PC parallel port the ABB_ARCN Server will run only 1 hour with all features enabled 4 The ABB_ARCN Server PCI version uninstallation will remove only the Server to remove also the SOHARD ARCNET Raw Drivers follow instructions from corresponding installation packages WNT_RAW_DRIVER_V0517 zip or W2K_RAW_DRIVER_V0517 zip ABB_ARCN DDE Server User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN DDE Server 5 Installing the I O Server Infrastructure The I O Server Infrastructure installation package can be supplied 1 Asa self extracting archive IOServerInfrastructure exe if downloaded from Klinkmann s web site 2 On CD or distribution disk floppy To install the I O Server Infrastructure from the self extracting archive run the l OServerInfrastructure exe and proceed as directed by the I O Server Infrastructure Setup program To install the I O Server Infrastructure from the CD or distribution disk on MS Windows NT or 2000 1 Insert the CD with Klinkmann Software into CD drive or insert the I O Server Infrastructure disk into a floppy drive A or B 2 Select the Run command under th
10. 00 13 MRK MRK 999 Parameter QUEL source variable value This value is unpacked before the current CE execution from the 3rd data word of the received package In our case from variable MW005 02 Parameter INDX index This variable is the 2nd data word of the received package Index value is calculated in the ABB_ARCN DDE Server Parameter BASI basic variable The target variable for write results from the INDX and the basic variables In address calculation the same type variable with group number 0 and channel number 0 A00 00 is used as a basic variable Use the alike CE for binary flags Item Name M writing also CE of indexed writing of word variables Use this CE only after write poke package receiving The following CE is used for word flag Item name MW writing Compare Point Type in the received package and constant value MW003 14 ABB_ARCN DDE Server User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN DDE Server 19 lf compared values are equal set 1 into the Block enable parameter Z1 MW005 00 Point Type 1st receive word Z2 MW003 14 Constant point type 106 Q M000 13 Block enable SPBM If a Block enable parameter M000 13 is 1 go to MRK 101 E M000 13 MRK MRK 106 IDSm FREI M000 13 QUEL MW005 02 INDX MW005 01 BASI MW000 00 Parameter QUEL source variable value This variable is the 3rd data word of the received package Parameter INDX index This variable is the 2nd
11. ABBCS31 ARCNET DDE Server for Microsoft Windows and InTouch Applications User Manual Ver 2 x Rev 2 5 DR 010 15 DR 010 16 KLINKMANN AUTOMATION P O Box 38 FIN 00371 Helsinki Finland Tel int 358 9 5404940 Fax int 358 9 5413541 www klinkmann com Klinkmann Automation ABB_ARCN DDE Server i Table Of Contents ABB_ARCN DDE Server User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN DDE Server 1 ABB CS31 ARCNET DDE Server The ABB CS31 ARCNET DDE Server ABB_ARCN is a Microsoft Windows program that acts as a DDE Dynamic Data Exchange Server and allows other Windows programs to access to data from ABB CS31 07KT93 Controllers The ABB CS31 ARCNET DDE Server requires an ARCNET adapter card e g ARCNET PC130E Network Controller Board based on the SMC ARCNET chip or SOHARD SH ARC PCI ARCNET card to communicate with ABB CS31 07KT93 Controllers Through this high speed communication network the Server can access up to 8 ABB CS31 07KT93 Controllers Program running on the ABB CS31 07KT93 Controller must be developed so that it ensures communication with the host through ARCNET bus There are two different ABB_ARCN Server versions described in this manual 32 bit version for ISA ARCNET cards ordering number DR 010 15 can be used on Microsoft Windows NT this version of Server uses WinRT kernel driver to access ISA ARCNET adapter card 32 bit version for SOHARD SH ARC PCI ARCNET card ordering number DR 010 16
12. CN DDE Server User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN DDE Server 13 ABB Package Description Topic Name nodel Package Number 1 Job Number Item Name Group Number Channel Number 15 _ Number Of Words To Be Received 1 _ o Binary Items Are Packed In Word Variable E Frequently Update Package The following describes each dialog field in this dialog box Job Number This field is used to enter the Job Number of the correspondent data package in the ASEND CE of ABB CS31 program For ABB CS31 this number must be from 0 to 31 Job Number must be unique Item Name This field is used to enter the Item Name of the first received item To select a necessary Item Name click on the combo box button and make your choice from list box Choices E A M K EW AW MW and KW see chapter Item Point Naming Group Number This field is used to enter the Group Number of the first received item see chapter Item Point Naming Channel Number This field is used to enter the Channel Number of the first received item see chapter Item Point Naming Number Of Words To Be Received This field is used to enter the Number Of Words To Be Received from the ABB CS31 in the corresponding data package Value must be equal to the parameter L0 of ASEND block in the ABB CS31 program For ABB CS31 valid number is from 1 to 125 words Note do not configure data package which exceeds the end of the corresponding
13. DDE Server 12 6 Click on the Board Name combo box to associate an ARCNET Network Controller Board with the topic Additional topics may be associated with this same ARCNET Board at a later time Note If this is the first time an ARCNET Board has been configured the user will be prompted to save it to an existing directory 7 Set the Update Interval field to indicate the frequency the items points on this topic will be read polled 8 Fill ARCNET Receive Data Packages Configuration list box enter information about send and all receive data packages used in communication between the PLC and the ABB_ARCN Server Data in this list box must correspond to ABB CS31 program For example your ABB CS31 program contains ASEND block with Configuration Order Number CON 1 see chapter ABB CS31 O7KT93 Program Description and the following parameters MW11 MW010 01 ST11 MOO 11 e JOB 12 e ENO M001 00 CON 1 e n0 1 e NO KW01 01 e D0 127 e J0 10 e 10 1 e Mwo EW07 15 e STO M00 00 e e EN11 M001 11 e n11 1 e N11 KW01 01 e D11 127 e J11 21 e L11 2 e e To enter information about the ASEND block with Configuration Order Number 1 choose the row number 1 in the list box for any ASEND block row number in the list box must be equal to the ASEND block Configuration Order Number and press Configure button or mouse left button double click The ABB Package Description dialog box will appear ABB_AR
14. E ccess Name Definition DDE Access Names Select the appropriate topic name and click on OK If the DDE Access Name has not been defined as previously described click on New and define the DDE topic now For integers and reals fill in the Min EU Max EU Min Raw and Max Raw fields These fields control the range of values which will be accepted from the Server and how the values are scaled If no scaling is desired Min EU should be equal to Min Raw and Max EU should be equal to Max Raw Enter the ABB_ARCN item point name to be associated with this tag name in the Item field in the Details box Initial Value 0 Min EU 32768 Max EU 32767 Deadband fo o siz Min Raw 32768 Max Raw 32767 Eng Units Conversion ice Linear DDE Access Name nodel Square Root ltem EWO7 15 O Use Tagname as Item Name Log Deadband oo i ABB_ARCN DDE Server User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN DDE Server 26 Refer to the Item Point Naming section below for complete details Where applicable the Use Tag name as Item Name option may be selected to enter automatically the tag name in this field Note The tag name can only be used if it follows the conventions listed in the Item Point Naming section When all entries have been made click on the Save button in the top dialog box to accept the new tag name To define additional Tag names click on the New button To return to the WindowMa
15. J00 of AREC block F7 00 __ High byte of Job Number always 00 F8 04 Low byte of Point Type for E 00 A 01 M 02 K 03 EW 04 AW 05 MW 06 KW 07 F9 0 0 High byte of Point Type always 00 FA Low byte of Index Index Group Number 16 Channel Number see chapter Item Point Naming FB 00 _ High byte of Index FD 00 The second byte of send package bit pattern FE 00 __ The third byte of send package bit pattern FF 00 The fourth byte of send package bit pattern Received Package example in case of write poke value 50 into Item MW50 01 is shown below O 02 Station address ofthe sender __ o Z o Co Unimportant information _ SSS O Unimportant information Hanae DIN identification always 7Fh Low byte of Job Number parameter J00 of AREC block F7 00 _ High byte of Job Number always 00 Z Low byte of Point Type for A 65h 101 M 66h 102 AW 69h 105 MW 6Ah 106 FQ 00 High byte of Point Type always 00 Z FA Low byte of Index Index Group Number 16 Channel Number see chapter Item Point Naming High byte of Index Low byte of write value 50 32h FD 00 _ High byte of write value S O FE 00 Notused o O FF 00 Notused o CE for the first word the 3rd word of the Received Package of bit pattern unpacking into binary variables to enable correspondent ASEND blocks Example current line comments start
16. and points that are alarmed logged or trended Defining the Tag names To define the Tag names associated with the new DDE Access Name invoke the Special Tag Name Dictionary command in WindowMaker then click on New The Dictionary Tagname Definition dialog box will appear Dictionary Tagname Definition Details Alarms Both None Tagname EW 7_15 Type DE Integer CL Log Data Log Events C Retentive Value Retentive Parameters Enter the Tag Name The tag name defined here is the name InTouch will use The ABB_ARCN Server does not see this name Select the tag type by clicking on the Type button The Choose tag type dialog box will appear ABB_ARCN DDE Server User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN DDE Server 25 Choose tag type H iis Frend Tag iD DOE Discrete DE Message indsect Pivereie Indirect Analog Indirect Message To access ABB_ARCN items the type must be DDE Discrete or DDE Integer Select the DDE type The Details dialog box for the tag name will appear Initial Value 0 Min EU o Max EU 9999 Deadband fo o Min Raw oo o e Max Raw 9999 Eng Units Conversion a Linear DDE Access Name Unassigned Square Root ltem O Use Tagname as Item Name Log Deadband oo i Select the ABB_ARCN topic Controller by clicking on the DDE Access Name button The Select a DDE Access Name dialog box will appear DD
17. ating Manual The following steps are taken to install the ABB CS31 example program 1 Insert the ABB_ARCN DDE Server disk into a floppy drive 2 Atthe DOS prompt type COPY A PROJEKT lt path to project file directory gt and press Enter default path C ABB SPS CS31 PROJEKT Before the ABB_ARCN DDE Server is started all connected ABB CS31 07KT93 Controllers must be initialized for the communication by loading the PLC application program to each Controller see chapter ABB CS31 07KT93 Program Description Configuring the ABB_ARCN Server After the ABB_ARCN Server is initially installed a small amount of configuration is required Configuring the Server automatically creates a ABB_ARCN CFG file which holds all of the topics Controllers definitions entered as well as the communication port configurations This file will automatically be placed in the same directory in which ABB_ARCN is located unless the path where the configuration file will be placed is specified via the Configure Server Parameters command To perform the required configurations start up the ABB_ARCN program If the Server starts up as an icon double click on the icon to open the server s window The following will appear ABB_ARCN l l me To access the commands used for the various configurations open the Configure menu ABB_ARCN Configure Board Configuration Topic Definition DDE Server Settings ABB_ARCN DDE Serve
18. below Do not reboot if message is displayed to activate some changes To uninstall the ABB_ARCN Server start Control Panel select Add Remove Programs and select the ABB_ARCN DDE Server the list of available software products Click on Add Remove and proceed as directed by the UnInstallShield program Before the ABB_ARCN DDE Server is used all connected ABB CS31 07KT93 Controllers must be initialized for the communication by loading the PLC application program to each Controller The example programs for communication with ABB_ARCN DDE Server are contained in the PROJEKT and PROJEKT2 subdirectories on the ABB_ARCN DDE Server distribution disk see chapters nstalling the ABB CS31 Example Program and ABB CS31 07KT93 Program Description Notes 1 The ABB_ARCN Server is developed with Wonderware I O Server Toolkit ver 7 0 and needs the Wonderware FS2000 Common Components to be installed on computer where the ABB_ARCN Server is running The Wonderware FS2000 Common Components are installed automatically when any of Wonderware FS2000 Components e g InTouch or some Wonderware I O server is installed 2 If ABB_ARCN Server will run on PC where Wonderware FS2000 Common Components are not installed then a special I O Server Infrastructure installation package can be obtained from Klinkmann Automation see Installing the I O Server Infrastructure section below This I O Server Infrastructure installation package contains
19. ce between Excel and the DDE Server the following lines should be added to the WIN INI file under the DDE Server heading AllowXLTable 1 DDE Server will accept XLTable format initializations from Excel This will significantly speed up the initialization of Excel Server Conversation ABB_ARCN DDE Server User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN DDE Server 29 AllowXLTableForPokes 1 DDE Server will accept XLTable format pokes from Excel This will significantly speed up the poke operations from Excel For example ABB_ARCN AllowXLTable 1 AllowXLTableForPokes 1 ABB_ARCN DDE Server User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN DDE Server 30 Troubleshooting WIN INI entries The first time you run the ABB_ARCN DDE Server configuration most of the items in the following list will automatically appear in the WIN INI file It is usually in the C WINDOWS directory It is an ASCII file and can be altered manually if you wish with any text editor e g MS Windows Notepad do not use a program that formats text such as MS Word or Write unless the file is saved as DOS text The following is a typical entry for the ABB_ARCN DDE Server ABB_ARCN ProtocolTimer 50 RequestTimer 1000 ValidDataTimeout 60000 DDEBlockSize 4096 WriteRetryIndefinitely 0 ConfigurationFile C ABB_ARCN Winlconic 0 WinFullScreen 0 WinTop 112 WinLeft 0 WinWidth 200 WinHeight 168 DebugMenu 1 ShowSend 0 ShowReceive 0 ShowE
20. cking Parameter J01 Job Number of the 2nd Send Package Parameter L01 Number of words of the user data to be sent The represented CE sends 1 data word value of variable MW03 00 CE with Configuration Order Number CON 8 ASEND ENO7 M001 07 CON 8 n07 00001 NO7 MW003 02 D07 00127 JO7 00017 LO7 00125 ST07 A62 15 MW07 MW050 00 Parameter ENO7 variable in this parameter here M001 07 must be equal to the parameter BIO7 in the UNPACK block the 3rd word of the Received Package unpacking Parameter J07 Job Number of the Send Package Parameter L07 Number of words of the user data to be sent The represented CE sends 125 consecutive data words Parameter MWO7 The first word variable of the sent package here MW050 00 CE with Configuration Order Number CON 12 ABB_ARCN DDE Server User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN DDE Server 21 ASEND EN11 M001 11 CON 12 n11 00001 N11 MW003 02 D11 00127 J11 00021 L11 00002 ST11 MOoO00 11 MW 11 MW010 01 Parameter EN11 variable in this parameter here M001 11 must be equal to the parameter BI11 in the UNPACK block the 3rd word of the Received Package unpacking Parameter J11 Job Number of the Send Package Parameter L11 Number of words of the user data to be sent The represented CE sends 2 consecutive data words Parameter MW 11 The first word variable of the sent package here MW010 01 In thi
21. e Start menu 3 Run STARTUP EXE if installing from CD or SETUP EXE if installing from distribution disk floppy 4 If installing from CD select Protocol Servers DDE SuiteLink OPC find I O Server Infrastructure and click on Setup 5 Proceed as directed by the I O Server Infrastructure Setup program To uninstall the I O Server Infrastructure start Control Panel select Add Remove Programs and select the IO Server Infrastructure from the list of available software products Click on Add Remove and proceed as directed by the UnInstallShield program Note The I O Server Infrastructure installation will be rejected if Wonderware FS2000 Common Components are already installed on same computer ABB_ARCN DDE Server User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN DDE Server 6 Installing the ABB CS31 Example Program The ABB CS31 example programs for communication with ABB_ARCN DDE Server are not installed by Installation program Each ABB CS31 example program is installed by copying all 15 files contained in the PROJEKT or PROJEKT2 subdirectory on the ABB_ARCN DDE Server distribution disk to a subdirectory on your hard disk where the Project Files for your ABB Procontic CS31 Programming System are located defaults ABB SPS CS31 PROJEKT or ABB SPS CS31 PROJEKT2 Before installing ABB CS31 example program you must install the ABB Procontic Programming System according to the Oper
22. eaningful name for each Controller and uses this name as the topic name for DDE references Note In some cases the term node is used interchangeably with the term topic Item indicates a specific data element within the specified topic With the ABB_ARCN Server an item is an individual point in the ABB CS31 07KT93 Controller memory The item point names are fixed by the ABB_ARCN Server as described in the Item Point Naming section Note In some cases the term point is used interchangeably with the term item Installing the ABB_ARCN DDE Server Installing the Server The ABB_ARCN Server installation package can be supplied 1 Asa self extracting archive 11015xxx EXE for ISA version or 11016xxx EXE for PCI version if downloaded from Klinkmann s web site the xxx is the current latest version of the Server 2 From installation on CD 3 On two or three distribution disks floppies To install the ABB_ARCN Server from the self extracting archive run the 11015xxx EXE or 11016xxx EXE and proceed as directed by the Server Setup program To install the ABB_ARCN Server from CD or distribution disks on MS Windows NT or 2000 1 Insert the CD with Klinkmann Software into CD drive or insert the ABB_ARCN Server Disk1 into a floppy drive A or B 2 Select the Run command under the Start menu 3 Run STARTUP EXE if installing from CD or SETUP EXE if installing from distribution disks floppies 4 If installing fr
23. entries have been made select OK to process the configuration for the ARCNET board Select DONE in the Adapter Board Settings dialog box when all ARCNET boards have been configured Notes 1 For Windows NT PCI version of ABB_ARCN DDE Server the Board I O Address and Board Memory Segment entries are disabled grayed 2 For Windows NT ISA version of ABB_ARCN DDE Server to add new ARCNET boards remove existing ones or change Board I O Address or Board Memory Segment for existing ARCNET boards configuration must be done from Administrator account or from other privileged account with Administrator rights 3 For Windows NT ISA version of ABB_ARCN DDE Server if you added new ARCNET boards removed existing ones or changed Board I O Address or Board Memory Segment for existing ARCNET boards to activate board settings WinRT kernel device must be restarted If ABB_ARCN DDE Server fails to restart WinRT kernel device you will need to reboot the computer to activate board settings ABB_ARCN DDE Server User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN DDE Server 10 Saving ABB_ARCN Configuration File If the configuration file does not currently exist or a new configuration path has been specified the Server will display the Save Configuration dialog box Save Configuration Configuration File Directory C INTOUCHS x Make this the default configuration file This dialog box displays the path where the
24. ged Dump Screen if checked then all information about packets is displayed in Server s window Dump displays all information about board active topics and data items All debug information except Dump Screen is displayed via the Wonderware Logger which must be active for these commands to work Warning if you check Show Send and or Show Receive debug output grows very fast ABB_ARCN DDE Server User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN DDE Server 33 Feb 95 May 95 Mar 96 Aug 97 Nov 97 Jul 2001 Dec 2002 Rev 1 0 Rev 2 0 Rev 2 1 Rev 2 2 Rev 2 3 Rev 2 4 Rev 2 5 KLINKMANN AUTOMATION ABB_ARCN DDE Server Revision History First Release Windows NT support added Server configuration dialog boxes changed Installation Program added Manual text modified Manual file name changed Troubleshooting features changed SUSPEND item added Chapter Notes on Write Command Processing added Support for SOHARD ARCNET PCI card added SuiteLink support added ABB_ARCN DDE Server User Manual Rev 2 5 01010M25
25. ialog box will appear Topic Definition Topics 2 To modify an existing topic select the topic name and click on Modify To define a new topic click on New The ABB_ARCN DDE Topic Description dialog box will appear Board Name fanc1 ABB Station Address Update Interval msec Max Supported Points 128 ARCNET Receive Data Packages Configuration First Item EW 07 15 Number of Items 1 First Item MW 03 00 Number of Items 1 First Item A 62 00 Number of Items 1 Packed Frequently First Item MW 40 00 Number of Items 1 First Item E 62 00 Number of Items 1 Packed First Item K 00 01 Number of Items 1 Unpacked First Item KW 00 00 Number of Items 12 First Item MW 50 00 Number of Items Defined Packages 12 Job Number for Send Package 3 Enter the Topic Name which corresponds to the DDE Topic Name The DDE Topic Name is entered in the DDE Access Name Definition dialog box described in the Using the ABB_ARCN Server with InTouch section 4 Enter the value in the ABB Station Address field Refer to the ABB CS31 Operational Manual for the correct address setting Note Each Controller must have an unique non zero address 5 Set the Max Supported Points for the Controller This field is used to enter the maximum number of DDE items supported by this topic Note Default value is 128 ABB_ARCN DDE Server User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN
26. item PLC memory area Binary Item Are Packed In Words Choose this option if received binary items are packed in word variable s in the ABB CS31 program This option is possible only for binary items E A M K see chapter Item Point Naming Frequently Update Package Choose this option if package must be received not only in its update period but also together with any received group of packages This option is useful for example for error or communication status detection Note It is recommended to use this option only if it is ABB_ARCN DDE Server User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN DDE Server 14 really necessary because otherwise it can hardly interrupt normal communication performance ABB CS31 07KT93 Program Description ABB CS31 07KT93 PLC ARCNET communication depends on the user developed PLC program The PLC memory areas are accessible from the ABB_ARCN Server if a PLC program contains corresponding connection elements CE which operate with the same areas Therefore ABB_ARCN Server user must develop his PLC application program or modify an existing program according to the following matters an application program must contain CE for ARCNET initialization an application program must contain CE for data package receive Four consecutive words in the PLC memory must be reserved for received data storage Received 4 words contains instructions for the PLC program an application prog
27. kage of the bit pattern unpacking into binary variables to enable correspondent ASEND blocks Example current line comments starts by Example UNPACK WORT MW 005 03 n 00016 BIOO M002 00 CON 17 BIO1 M002 01 CON 18 BI02 M002 02 CON 19 BIO3 MO002 03 CON 20 B104 M002 04 CON 21 BIOS MO002 05 CON 22 BIOG M002 06 CON 23 BIO7 M002 07 CON 24 BI08 M002 08 CON 25 BIO9 MO002 09 CON 26 BI10 M002 10 CON 27 ABB_ARCN DDE Server User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN DDE Server 18 Bl11 M002 11 CON 28 Bl12 M002 12 CON 29 BI13 M002 13 CON 30 Bl14 M002 14 CON 31 BI15 M002 15 CON 32 For detailed description see CE for the first word of the bit pattern unpacking into binary variables Perform this CE only in case of read poll package receiving for CONSs 17 32 CE of indexed writing of binary variables Use these CE only after write poke package receiving The following CE are used for binary output Item name A writing Compare Point Type in the received package and constant value MWO003 11 If compared values are equal set 1 into the Block enable parameter Z1 MW005 00 Point Type 1st receive word Z2 MW003 11 Constant point type 101 Q M000 13 Block enable SPBM If a Block enable parameter M000 13 is 1 go to MRK 101 E M000 13 MRK MRK 101 MRK MRK MRK 101 IDSB perform indexed writing FREI M000 13 Block enable QUEL M000 15 INDX MW005 01 BASI A00 00 SPBM E M0
28. kage contains constant value 999 ASEND EN M003 00 n 00001 N MW003 02 D 00127 J 00031 L 00001 ST MO000 12 MW MW003 15 CONSTANT VALUE 999 Note To access data from PLC running example program Projekt2 ABB_ARCN the Server should be started with configuration file ABB_ARCN CFG supplied with installation disks and Topic configuration parameter Job Number for Send Package should be changed from 10 to 31 ABB_ARCN DDE Server User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN DDE Server 23 Using the ABB_ARCN Server with InTouch To access items points on ABB CS31 07KT93 Controllers from InTouch the following steps all performed in WindowMaker are required To define the DDE Access Names in WindowMaker for each Controller invoke the Special DDE Access Name Setup command The Select a DDE Access Name dialog box will appear DDE Access Name Definition DDE Access Names Click on Add The DDE Access Name Definition Dialog Box will appear DDE Access Name Definition DDE Access Name DDE Application Server Name ABB_ARCN DDE Topic Name node1 Handling of initial data yalues Request initial data Wait for change When to advise server Advise all items Advise only active items Note If Add is selected this dialog box will be blank when it initially appears Data has been entered here to illustrate the entries which are made The following three fields are required ent
29. ker main screen select Done Controller STATUS Item For each Controller there is a built in discrete item which indicates the state of communication with the Controller The discrete item Status is set to 0 when communication with the Controller fails and set to 1 when communication is successful From InTouch the state of communication with the Controller may be read by defining a DDE Discrete tag name and associating it with the topic configured for the Controller and using Status as the tem name Initial Value Input Conversion On Msg DDE Initialized aa le Direct Reverse Off Msg DDE Uninitialized DDE Access Name nodel On Item STATUS O Use Tagname as Item Name From Excel the status of the communications may be read by entering the following formula in a cell ABB_ARCN topic STATUS Item Point Naming Within the ABB_ARCN Server item point naming depends on ABB Procontic CS31 system operand naming conventions The tables below list the item point names supported by the ABB_ARCN DDE Server BINARY points DDE Tag Type eee ees ae ae E _ BINARY input E00 00 E63 15 BINARY output A00 00 A63 15 M BINARY flag M00 00 M255 15 K BINARY Indirect constant K00 00 K00 01 ABB_ARCN DDE Server User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN DDE Server 27 WORD points DDE Tag Type bes eet es ae ieee ee ed Ew WORD input EW00 00 EWO7 15 AW WORD outpu
30. nable Server interface with SOHARD SH ARC PCI ARCNET card 1 Add the following two rows to WIN INI file usually located in Windows main directory e g C WINNT ABB_ARCN PCICard 1 2 Install tha SOHARD SH ARC PCI ARCNET and driver Unpack the driver installation WNT_RAW_DRIVER_V0517 zip or W2K_RAW_DRIVER_V0517 zip to some temporary location Switch off PC and insert the ARCNET card in any free PCI slot Turn on the PC When the Found New Hardware Wizard is started check Search for recommended Leave the checked state Specify a location only Enter a full path where installation of SH RAW driver is located In the next dialog box the Wizard must found the device Network Controller At the end click on Finish ABB_ARCN DDE Server User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN DDE Server 4 For more information how to install the SOHARD SH ARC PCI ARCNET and driver refer to readme html included in the WNT_RAW_DRIVER_V0517 zip or W2K_RAW_DRIVER_V0517 zip Note Always check if there is newer driver version supplied together with SOHARD SH ARC PCI ARCNET card in this case use the newest version supplied with card 3 Start the ABB_ARCN Server Ignore press OK message displayed regarding WINRT settings Check if Board I O Address and Board Memory Segment entries are disabled grayed in the ARCNET Adapter Card Settings dialog box see Board Configuration Command section
31. ollers may be accessed from Excel spreadsheets To do so enter a formula like the following into a cell on the spreadsheet ABB_ARCN topic item Sometimes Excel requires the topic and or item points to be surrounded by apostrophes In the formula topic must be replaced with one of the valid topic names defined during the Server configuration process Replace item with one of the valid item point names described in the Item Point Naming section Reading Values into Excel Spreadsheets Values may be read directly into Excel spreadsheets by entering a DDE formatted formula into a cell as shown in the following examples ABB_ARCN node1 EW7 15 Writing Values to ABB_ARCN Points Values may be written to the ABB_ARCN Server by creating an Excel macro which uses the DDE POKE Command The command is entered in Excel as follows INITIATE ABB_ARCN Topic Name POKE Channel_ld Item Data_Reference RETURN For Channel_ld use the cell reference where the INITIATE statement is found For Data_Reference use the cell identification which contains the POKE value Some applications have a limited number of channels therefore they should be closed when finished by using a TERMINATE statement in the macro The TERMINATE macro should have sufficient delay to ensure that the POKE has been executed Refer to the Excel Manual for further details Improving Excel DDE Server Performance To improve communication performan
32. om CD select Protocol Servers DDE SuiteLink OPC find ABB_ARCN DDE Server ISA or ABB_ARCN DDE Server PCI and click on Setup 5 Proceed as directed by the ABB_ARCN Server Setup program ABB_ARCN DDE Server User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN DDE Server 3 ABB_ARCN DDE Server for Windows NT must be installed from Administrator account or from other privileged account with Administrator rights When installation is finished the subdirectory specified as a folder where to install the ABB_ARCN Server files will contain the following files ABB_ARCN EXE The ABB_ARCN Server Program This is a Microsoft Windows 32 bit application program ABB_ARCN HLP The ABB_ARCN Server Help file ABB_ARCN CFG An example configuration file LICENSE TXT Klinkmann Automation software license file WNT_RAW_DRIVE SoHard ARCNET Raw Driver v5 17 installation package for MS R_V0517 zip Windows NT needed only for PCI version W2K_RAW_DRIVE SoHard ARCNET Raw Driver v5 17 installation package for MS R_V0517 zip Windows 2000 needed only for PCI version manual_SH_ARC_ SoHard ARCNET PCI Card User Manual PCI_e pdf PROJEKT ZIP Packed file containing ABB CS31 O07KT93 example program with no response to write commands PROJEKT2 ZIP Packed file containing ABB CS31 O07KT93 example program processing response to write commands After the Server is installed the following additional steps are necessary to e
33. r User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN DDE Server 7 DDE Server Settings Command A number of parameters that control the internal operation of the Server can be set In most cases the default settings for these parameters provide good performance and do not require changing However they can be changed to fine tune the Server for a specific environment To change the Server s internal parameters invoke the DDE Server Settings command The DDE Server Settings dialog box will appear DDE Server Settings Protocol Timer Tick msec C NetDDE being used Configuration File Directory E INTOUCHS The following describes each field in this dialog box Configuration File Directory The first field is used to specify the path disk drive and directory in which ABB_ARCN will save its current configuration file ABB_ARCN will use this path to load the configuration file the next time it is started Note Only the path may be modified with this field The configuration file is always named ABB_ARCN CFG Note There is no limit to the number of configuration files created although each must be in a separate directory When using the ABB_ARCN Server with InTouch it is good practice to place the configuration file in the application directory Protocol Timer Tick This field is used to change the frequency at which the Server checks for data to process This should be approximately 2 to 4 times the fastest ra
34. ram must contain CE groups for indexed writing of binary and word variables an application program must contain 1 32 CE for data sending Each data send CE can send the portion of data which parameters data type start address and sent word number 1 125 is set during the PLC program development and are unchangeable during program performance Any portion of data you need to access must be represented in one of the data send CEs if system is configured to process an answer to write commands then an application program must contain CE for sending response to write command if you need to access binary data necessary number of words must be reserved for binary data packing and corresponding CE must be used to send the packed data to the server an application program must contain CE for the bit pattern unpacking to recognize which data send CE must be executed After the PLC program startup it initializes ARCNET communication and waits for instructions from the server If the change value command is received the PLC program performs necessary actions but does not send any response to the PLC If the data request command is received the PLC program sends requested data to the server All these features illustrates a PLC example program An example program is developed using ABB Procontic Programming System software version 05 94 Program contains a link of CE full of PLC program text see using ABB Procontic Programming System CE edi
35. ries when entering a DDE Access Name Definition DDE Access Name Enter an arbitrary name which will be used by InTouch to refer to the topic Controller It is recommended that the name defined for the topic Controller in ABB_ARCN also is used here DDE Application Server Name Enter the application name ABB_ARCN which the DDE Server is used to accessing the Controller DDE Topic Name Enter the name defined for the topic in ABB_ARCN to identify the Controller the ABB_ARCN Server will be accessing ABB_ARCN DDE Server User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN DDE Server 24 Note This will usually be the same as the DDE Access Name although if desired they may be different However it must be the same name used when the topics were configured in section Configuring the ABB_ARCN Server Request Initial Data This option may be selected if the Server is other than a Wonderware DDE Server and the Server does not return data values immediately when a window is displayed This option is not applicable to the ABB_ARCN DDE Server Wait for Change This option should be selected for the ABB_ARCN DDE Server Advise all Items This option may be selected if the Server is to poll for all data whether or not it is in visible windows alarmed logged or trended Use of the option is not recommended Advise only active Items Selecting this option will cause the ABB_ARCN Server to poll only points in visible windows
36. rrors 1 Verbose 0 WriteRetryCount 3 ConsecArcnErrorsForLog 1 maxPossiblePackages 4 ShowAllRejectedWrites 4 The WriteRetryCount entry is used to configure the Server to wait the responses to write commands If you want to receive responses to write messages then some non zero value must be assigned to WriteRetryCount item A good choice is 2 with this setting the Server performs the second write attempt if the first attempt was unsuccessful If WriteRetryCount value is 3 then three write attempts are performed etc The PLC program should be able to send a response to write command like the ABB CS31 example program PROJEKT 2 If WriteRetryCount value is 0 then the response to write messages is not sent as in ABB CS31 example program PROJEKT In this case the Server internally is set to perform the second write attempt if write command is not transferred to PLC The Server can not get information if write command is processed inside PLC therefore write command execution in this case is not reliable enough The ConsecArcnErrorsForLog entry is used to control number of error messages logged to WW Logger file ABB_ARCN DDE Server User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN DDE Server 31 1 If ConsecArcnErrorsForLog 0 then each time when ARCNET communication error happens and Show Errors is checked in the Server s System Menu an error message is logged to WW Logger file 2 If ConsecArcnErrorsForLog 1 4 then ARCNET
37. s by ABB_ARCN DDE Server User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN DDE Server 17 UNPACK WORT MW005 02 n 00016 BIOO M001 00 CON 1 BI01 M001 01 CON 2 BI02 M001 02 CON 3 BI03 M001 03 CON 4 B104 M001 04 CON 5 BIOS M001 05 CON 6 BIOG M001 06 CON 7 BIO7 M001 07 CON 8 BI08 M001 08 CON 9 BI09 M001 09 CON 10 BI10 M001 10 CON 11 BI11 M001 11 CON 12 BI12 M001 12 CON 13 BI13 M001 13 CON 14 BI14 M001 14 CON 15 BI15 M001 15 CON 16 Parameter WORT Word variable to be unpacked This parameter is the 3rd data word of the received package Parameters BIO0 BI15 binary variables used for the ASEND block enabling When you develop a PLC program you must give an unique 1 32 Configuration Order Number CON to every send block This CON does not depend on actual block sequence in the PLC program jet an every package send job enable variable must be set in the UNPACK block according to the CON For example if the send block is given CON number 3 its job enable variable must be set in the UNPACK in the position marked BI02 Given CON is used during Topic configuration see chapter Topic Definition Command Remember given Configuration Order Numbers and use them correctly If you disarrange CONs correct PLC and ABB_ARCN Server performance will be impossible Perform this CE only in case of read poll package receiving for CONs 1 16 CE for the second word the 4th word of the Received Pac
38. s case binary variables are previous packed by CE PACK into the sent package word variables MW010 01 and MW010 02 Sent Package example in case of read Item MW050 01 is shown below O0 01 Station address of the sender __ o 1 02 Station address of the receiver ____ 2 03 Continuous pointer address of the first user data byte 3 7F DINidentification 7Fh 4 11 _ Low byteofJob Number parameter J07 of SASEND block 5 00 _ High byte of Job Number always 00 Low byte of Item MW050 00 the 1st variable of the user data words 7 00 High byte of Item MW050 00 EARRA Low byte of Item MW050 01 the 2nd variable of the user data words 9 00 High byteofltem MW050 01 Items from MW050 02 to MW057 12 fore i esl Low byte of Item MW057 13 the 125th variable of the user data words FF 00 __ High byte of Item MW057 13 CE to initialize memory area in the operand memory with zero We must set to zero word flags of received package after each processing of theirs INITS 0 1 A62 05 n 00004 VAR MW005 00 All described CEs location and dependencies see in the full example text PROJEKT or PROJEKT2 For more detailed CE parameters explanation see ABB Procontic Programming System Library of Connection Elements ABB Procontic CS31 ABB_ARCN DDE Server User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN DDE Server 22
39. t Integer AW00 00 AW6 15 WORD flag MW000 00 MW255 1 5 Kw WORD Indirect constant KW00 00 KW39 15 It is recommended that you use consecutive addressing for item point naming for example MW001 01 MW001 02 MW001 03 etc This will greatly increase the performance of ABB_ARCN DDE Server Special write only DDE Discrete Item SUSPEND may be used to control communication with a separate topic If application changes Item s value from 0 to 1 then communication with topic is suspended If Item s SUSPEND value is changed back to 0 communication with topic is resumed Note When topic is suspended by setting SUSPEND item to 1 the Server rejects all write values to this topic Item Point Naming Examples The following examples show the correct format for item point names e E01 15 BINARY Input CS31 bus Group number 1 Channel number 15 e A03 00 BINARY Output Group number 3 Channel number 0 e M113 13 BINARY Flag Group number 113 Channel number 13 e K00 00 BINARY Constant Group number 0 Channel number 0 e EWO2 01 Analog WORD Input Group number 2 Channel number 1 e AW03 02 Analog WORD Output Group number 3 Channel number 2 e MW255 11 WORD Flag Group number 255 Channel number 11 e KW38 04 WORD Constant Group number 38 Channel number 4 ABB_ARCN DDE Server User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN DDE Server 28 Notes on Using Microsoft Excel Data from ABB_ARCN topics Contr
40. te desired to update data from the ABB CS31 07KT93 hardware PLC program s cycle time should also be taken into account when configure this parameter For example PLC program s cycle time is 100 milliseconds If data from PLC is accessed by one PC then Protocol Timer Tick should be 100 milliseconds or a bit greater If two PCs access data from PLC simultaneously then Protocol Timer Tick should be 200 milliseconds or a bit greater on each PC NetDDE being used Select this option if you are networking using NetDDE When all entries have been made click on OK To reset the default values click on Defaults ABB_ARCN DDE Server User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN DDE Server 8 Board Configuration Command ARCNET Network Board configuration for Windows NT version of ABB_ARCN DDE Server must be done from Administrator account or from other privileged account with Administrator rights To configure the ARCNET Network Board invoke the Board Configuration command The Adapter Board Settings dialog box will appear Adapter Board Settings ARCNET Boards Select the ARCNET Network Board and click on Modify to examine the characteristics of the selected Board The ARCNET Adapter Card Settings dialog box will appear ARCNET Adapter Card Settings Reply Timeout msec Board Address fi Board 70 Address Board Memory Segment DO00 The following describes each dialog field in this dialog box
41. that contains the data and the item name is the specific cell on the spreadsheet With InTouch the application name is View the topic name is the word Tag name when reading writing to an InTouch tag name and the item name is a specific tag name in the InTouch Data Dictionary When a client application sets up a link to another DDE program it requests the server application to advise the client whenever a specific item s value changes These data links will remain active until either the client or server program terminates the link or the conversation They are a very efficient means of exchanging data because once the link has been established no communication occurs until the specified data value changes ABB_ARCN DDE Server User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN DDE Server 2 InTouch uses DDE to communicate with I O device drivers and other DDE application programs Accessing a Remote DDE Item from ABB_ARCN The DDE protocol identifies an element of data by using a three part address including Application Topic and Item Application refers to the name of the Windows program server that knows how to access the data element In the case of data coming from or going to ABB CS31 07KT93 hardware the application portion of the DDE address is ABB_ARCN Topic is an application specific sub group of data elements The ABB_ARCN Server considers each ABB CS31 07KT93 Controller to be a separate topic The user creates m
42. tor for successful communication between PLC and ABB_ARCN DDE Server The following CE are important CE for initialization of the ARCNET controller The following parameters are set interrupt after reception of a data package only short package 256 bytes data packages to all stations ABB_ARCN DDE Server User Manual Rev 2 5 01010M25 Klinkmann Automation ABB_ARCN DDE Server 15 Example AINIT 0 1 M255 15 DONE A62 00 TO MW 003 00 ERR A62 01 NODE MW 000 00 STAT MW000 01 DIAG MW000 02 TOS A62 02 TOND MW 000 03 TOJN MW000 04 LEV MW 000 05 RECO A62 03 Parameter TO Timeout in ms waiting time for sending data packages This parameter value must be less than parameter Update Interval see Topic Definition dialog box in chapter Topic Definition Command and parameter Replay Timeout see Board Configuration dialog box in chapter Configure Board Command Parameter TOS timeout has occurred during send operation CE for data package receive Only one data receive package is used to receive data from the ABB_ARCN Server The received 4 words of package data contains instructions to ABB CS31 program The 1st received word identifies the data type the ABB_ARCN Server and the ABB CS31 program operates with at the present moment as well as operation type read or write to be performed by the PLC program The 2nd received word contains accessing variable index see IDSm block description in the ABB Procontic

Download Pdf Manuals

image

Related Search

Related Contents

Istruzioni per l`uso NOVAALPIN 301 B/T NOVAALPIN 261  Analyst Training v1.1  SERVICE MANUAL - CNSI Microfluidics Lab  JVC TS-C50P2G User's Manual  IBM System Storage DCS9900 Storage Manager Reference Guide  PRODUCT SPECIFICATION  Manual do Programa Open License 2011-2012  Shark EP035T2 Vacuum Cleaner User Manual  AY-M25 Installation & Operating Manual  Hardware Keylogger User Guide - KeyGrabber PS/2  